1 SDS SERIES DC SUBMERISIBLE PUMPS INSTALLATION MANUAL Kyocera Solar, Inc. / SOLARJACK, 7812 E. Acoma Drive, Scottsdale, AZ Telephone (800) FAX (480) info@kyocerasolar.com
2 Section 1 NOTE: Read sections 2 and 3 carefully before attempting to install this pump. Improper installation will void your warranty. SOLARJACK S SDS SERIES DC SUBMERSIBLE PUMPS SOLARJACK S SDS SERIES PUMPS are positive displacement, low voltage, DC powered, submersible pumps. Constructed of high quality marine bronze and stainless steel, these pumps were designed for corrosion free service in clean potable water. They can be installed in a well, cistern, lake, or stream. If used in conjunction with a pressure switch and tank, they may be used to pressurize a water system. The SDS-D series pump's light weight, only 14 pounds, and small size 3.8 outside diameter and length allows easy installation by hand into a 4 inside diameter well. The SDS-Q series pump, weighing 16.5 pounds and with a 4.3 outside diameter, also allows easy installation by hand into a 5 inside diameter well. Their stand-alone, pollution free and low noise operation makes them an ideal solution for remote home, wildlife, and stock watering problems, without violating the environment. Simplicity is the key feature of the SDS series pump line. They require no lubrication, they run on 12 volts or 24 volts DC and are completely serviceable. A variety of power sources may be used including solar panels, wind generator, batteries, or any combination of the three. (A SOLARJACK PC or PB series controller must be used as an interface between the power source and the pump on all systems). All new generation SDS series pumps are designed to meet the National Electric Code. The necessary changes have been made to all SOLARJACK pumps and controllers to meet this code. INSTALLATION INSTRUCTIONS Section PUMP 2.la Before installing the pump, measure the depth and static water level of the well. The static water level is the distance from the top of the casing to the water level in the well. This information is necessary in determining where to set the pump and the low water cut-off electrodes, if used. 12/06/99 2
3 2.lb Connect the drop pipe, safety rope, and sand shroud (if used) to the pump. Splice the drop wire to the motor lead and stretch it all out on the ground. See the wire splicing instructions in section 2.3 (Be careful not to get any dirt inside the drop pipe when stretching it out on the ground). If a saw is used to cut the drop pipe, make sure to clean the saw cuttings out of the pipe before Installation). Make the length of the pipe assembly a minimum of two feet longer than that of the static water level plus the anticipated draw down of the water level in the well. Never install the pump deeper than necessary. 2.lc Tie the drop pipe, drop wire, and safety rope together every ten feet with the wire ties or a high quality black electrical tape. (If the low water cut-off circuit- is used, attach the E-lS electrodes at the proper set points at this time also). Slide the well seal over the discharge end of the pipe, connect the discharge fitting, pull the drop wire through the seal, and connect the safety rope to the I-Bolt. 2.ld Lower the pump and pipe assembly into the well positioning the well seal over the top of the casing. 2.le Connect the discharge pipe to the fitting on top of the well seal and attach the pump wires and electrode wires (if used) to the controller. 2.2 PANEL SUPPORT STRUCTURE 2.2a The panel support structure should be located as close to the well as possible. This keeps the length of the drop wire and thus the voltage drop to a minimum. It must also be mounted in a good sunlight location away from trees, buildings, or anything that could cast a shadow on the panels. 2.2b Dig an 8 to 10 diameter hole to a depth of at least 24 inches. (This is for a 2-module support structure.) 2.2c Install the support structure pipe into the hole making sure that the pipe is plumb and then fill the hole with concrete. Allow 24 hours for the concrete to cure before installing the panels. 2.2d After the concrete has cured, install the panel support head (B) on the support structure pipe (E). Attach the upright (C) onto the head using the 5/8 bolt tabs (A). Attach the cross pieces (D) onto the upright using the 3/8 bolts. Attach the panels onto the cross pieces using the 1/4 bolts. (See separate instructions for other types of support structures and trackers.) 2.2e Cover the panels with a blanket or opaque material before wiring the panels to the controller and pump. CAUTION: PV PANELS GENERATE DC ELECTRICITY WHEN EXPOSED TO SUNLIGHT. 2.2-f Connect the panels and controller as illustrated in the wiring diagrams in the controller manual. 12/06/99 3
4 2.2g Remove the blanket from the panels and turn the switch on. If there is good sunlight the pump will start operating. 2.3 WIRE SPLICING 2.3a Prepare the cable by stripping the outer jacket insulation back 1-1/2 on the pump end and 2-1/2 on the incoming power end. (The insulation on the outer jacket of the long side is stripped back just enough to allow the smaller shrink tube to fit over the inner wire and allow the compression sleeve to be installed). 2.3b Prepare the inner wire ends by stripping the insulation to expose about 1/4 of each conductor. 2.3c Slip the large length of tubing over the entire cable and the smaller tubing over each wire on the long side. Splice the wires to the motor pigtail using the proper crimping tool and compression sleeves. Observe the colorcoding. 2.3d Position the small shrink tubing over each joint, making sure it is centered. Apply heat to the shrink tubing with a flame from a lighter or a propane torch. If using a torch, keep the flame moving to prevent burning the tubing. Proper shrinkage is reached when the tubing does not show any further reduction in size and the sealant has started to ooze at the ends. 2.3e Position the large shrink tubing over the entire joint making sure it is positioned over each side of the outer wire jacket. Apply heat until the proper shrinkage is reached. 2.3f To check proper sealing of the splice and wire installation immerse the splice and wire in a container of water for ten minutes and then take a resistance reading between the water and each of the cable conductors. Connect one ohmmeter lead to the conductor and the other lead to a piece of metal immersed- in the same water. Set the ohmmeter on the R x IOOK scale. The resistance should be two megohms (2 million ohms) or higher. A lower resistance indicates an insulation leak that must be corrected. 2.4 CONTROLLER ADJUSTING PROCEDURE NOTE: It is usually not necessary to adjust the controller since it has been pre-adjusted at the factory. 2.4a This procedure should be performed with the panels at their normal operating temperature at mid-day. To maintain peak output throughout the year, readjust the controller in very hot and very cold weather or as necessary. 2.4b With the system installed and pumping water, turn the panels away from the sun or cover the panels until the pump flow rate is reduced by approximately 50%. 2.4c Connect a DC volt-meter to the pump side of the controller. (LD+ and LD-) 2.4d Turn the "panel voltage adjusting pot", located on the upper left side of the controller, until the highest possible voltage is obtained. (This will also be the highest flow rate). 12/06/99 4
5 2.4e Return the panels to their normal position. The pump will then operate at its maximum output. 2.5 ELECTRODE INSTALLATION (OPTION) 2.5a With the pump and pipe stretched out on the ground and before installation into the well, (refer to step 2.1b) cut the electrode wire to the desired lengths and install all three E1-S electrodes in the proper locations. 2.5b The "ground electrode", terminal 3, must be in the water at all times and should be placed approximately two inches above the top of the pump. The "low water level electrode" terminal 1, is placed at the desired cut off point and is usually placed two to six inches above the ground electrode. The "high water level electrode", terminal 2, is placed at the desired turn-on level, but must be placed below the static water level and should be located no more than 20 feet from the low water electrode. NOTE: Wells with a high mineral content in the water and/or with cascading water above the electrodes may not be suitable for use with the low water cut-off circuit. Mineral deposits may collect on the electrodes insulating the circuits from the water. FOR PROPER PUMP PERFORMANCE Section 3 (Do not disassemble the pump during the warranty period. Any tampering will void your warranty). WARNING: IF THE PUMP IS DISASSEMBLED, USE EXTREME CAUTION AS THE MOTOR HOUSING MAY BE UNDER HIGH PRESSURE. 3.la For optimum pump performance make sure that the wire is sized properly for the length of run between the pump and the panels. Wire sized too small will cause a decreased output from the pump. Keep the distance from the PV panels to the pump as short as possible. For depths over 150 feet, higher wattage panels will help compensate for the additional losses in the longer wire lengths as well as the higher current requirements. 3.lb Make sure that the discharge pipe is sized properly for the length of run. Friction loss in a pipeline, especially over a long distance, will add head to the pump and thus reduce the flow rate. (Consult your SOLARJACK dealer for correct sizing for your system). 3.lc Never rest the pump on the bottom of the well, lake, cistern, etc. This can cause the pump to fill with mud and damage the diaphragm as well as reduce the flow of water past the motor and may cause overheating problems. Suspend the pump five feet or more above the bottom of the well. 3. 1d Use no larger than 1/2 drop pipe on SDS-D series pumps and 3/4 on SDS-Q series pumps. Because of the low flow rates the velocity of the water in larger pipes is not fast enough to carry small particles to the surface. These particles may settle inside the pump as well as the drop pipe causing pump damage as well as restricting the flow of water. If there is a known sand problem, a sand shroud or a screen is required. (Please note that the minimum well casing diameter for the SDS-D series shroud is 5 and the SDS-Q series shroud is 6 ). Damage to the pump caused by sand will void your warranty. It is 12/06/99 5
6 highly recommended that all pumps be installed with sand shrouds for maximum pump protection. 3.le Due to the aggressive action of DC power, it is essential that the wire splice at the pump be made correctly. This splice must be watertight. Improper sealing of this splice will cause poor pump performance and may cause damage to the controller. SOLARJACK S splice kit #S-703 is recommended for this watertight connection. 3.lf Never install the pump over 60 feet below the static water level. Excessive water pressure on the pump may cause seal damage and allow water to enter the motor housing. 3. 1g Never chlorinate a well while the pump is installed. Heavy concentrations of chlorine will damage the diaphragm and seals. 3.lh Never install the pump in a well that has or has had an oil lubricated line shaft turbine in it. Any drip oil remaining in the well will damage the diaphragm and seals. 3.li If the pump is used in a well over l00 feet deep, install a poppet type check valve on top of the pump. This will help relieve some of the pressure on the internal check valves and will keep any sediments from falling back into the pump. TROUBLESHOOTING Section PUMP DOES NOT RUN 4.la Check wiring diagrams for proper connections. 4.lb Check for proper panel, controller, and/or battery voltage with a volt meter. If our pump controller is being used, a quick look at the indicator lights will verify power coming from the panels going to the controller and power coming from the controller going to the pump. If the red light is on and the green light is not, connect a jumper wire across terminals 6 (PV-) and 7 (LD-). This will bypass the controller and will allow the pump to run panel direct. 4.lc Check the splice above the pump for proper connections. 12/06/99 6
7 4.ld Check for a broken wire leading to the pump. 4.le Check to see if the water level is above the top electrode, if the low water cut-off circuit is being used. (Turn dip switch #5 off and switch #6 on to bypass the low water cut-off circuit.) 4.lf Check for an open motor winding. (With an ohmmeter set on the R x 1 scale check between the two pump wires. Meter reading should be between.5 and 50 ohms. If the resistance is higher than this, disconnect the pump at the splice above the pump and check again). 4.lg Check the controller for proper adjustment. If the controller is adjusted wrong the pump flow rate will be low. If the voltage setting is higher than the input voltage, the controller will not turn on. (See section 2.4) 4.lh Check to see if the float switch, if used, is functioning properly. (Disconnect wires from terminals 4 & 5 to bypass the float circuit). 4.2 PUMP RUNS BUT DOES NOT PUMP WATER 4.2a Check to see if the pump is below the surface of the water. 4.2b Check for holes in the drop pipe. 4.2c Check for a plugged suction screen or pump full of mud, sand, or pipe cuttings. (If the pump is full of mud or sand, hold the pump upside down in a bucket of water and allow it to pump until all the mud clears). 4.2d Check for a plugged drop pipe or discharge pipe. 4.2e Check to see if the controller is adjusted properly. (See controller adjusting procedure section 2.4) 4.3 EXCESSIVE CURRENT DRAW (Over the normal amperage rating of the pump). 4.3a Check wiring diagrams for proper connections. 4.3b Check for skinned wires or faulty underwater splice. (See section. 2. 3d) 4.3c Check for a locked motor armature. (With the pump out of the well, bypass the controller and connect power directly to the motor leads. If the pump still does not run and the current is over 1.5 amps, the pump is in a locked or loaded rotor condition and must be repaired). NOTE: New pumps will draw slightly higher current for approximately 30 days. With the new heavy duty bearings and long life brushes the pump goes through a longer break-in period. 12/06/99 7
8 4.4 DECREASED PUMP OUTPUT 4.4a Check for a plugged suction screen. (Pull the pump and clean the screen). 4.4b Check for holes in the drop pipe. 4.4c Check for a restriction in the drop pipe. 4.4d Check to see if the water level in the well has dropped lower than normal or below the pump. 4.4e Check for mud or sand packed inside the pump or drop pipe. (If the pump is full of mud or sand, hold the pump upside down in a bucket of water and allow it to pump until all the mud clears. If the pipe is plugged with sand, clean the sand out of the pipe and install a SOLARJACK sand shroud around your pump). 4.4f Check the controller for proper adjustment. A controller being out of adjustment will cause decreased flow rates. (See section 2.4) 4.4g Check for the correct pump motor polarity. The black motor lead is always negative and the red motor lead is always positive. If these leads are reversed increased motor current and decreased pump flow rates will occur. 4.4h Check for dirt on the array or partial shadowing of the array. 4.5 PUMP RAPID CYCLING 4.5a If the low water cut-off circuit or high water cut-off circuit is being used, check to see if the high and low electrodes have been reversed. 4.5b If a pressure switch is being used, make sure a pressure tank is installed. 4.5c If a pressure tank is being used, make sure the tank is not water logged. 4.5d If a diaphragm pressure tank is being used, make sure the air pressure in the tank is 2 pounds less than the cut-in pressure, with the tank empty. WARNING: IF THE PUMP IS DISASSEMBLED USE EXTREME CAUTION AS THE MOTOR HOUSING MAY BE UNDER HIGH PRESSURE. REMEMBER, THIS VOIDS All WARRANTY. 12/06/99 8
9 12/06/99 9
10 12/06/99 10
11 12/06/99 11
12 12/06/99 12
OPERATION AND INSTALLATION MANUAL
OPERATION AND INSTALLATION MANUAL SCS 1, 1 1/2 & 2 HP SERIES SOLAR ELECTRIC PUMPS MANUFACTURED & SERVICED BY: SUNPUMPS 325 EAST MAIN STREET SAFFORD, ARIZONA 85546 UNITED STATES OF AMERICA PHONE # (928)
More informationCC 2000 Controller. Accommodates Arrays with two to twelve 36-cell Modules in Series; Will Operate from 24 to 144 volt Battery Banks
CC 2000 Controller Accommodates Arrays with two to twelve 36-cell Modules in Series; Will Operate from 24 to 144 volt Battery Banks Maximum Power Point Tracking Self Programming Operation Current Boosting
More informationSOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL
SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL INSTALLATION AND OPERATION SWP SERIES MANUFACTURED BY: Aquatec International, Inc. 17422 Pullman Street Irvine, Ca. 92614 United States of America
More informationSOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL
SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL INSTALLATION AND OPERATION SWP SERIES MANUFACTURED BY: Aquatec International, inc. 17422 Pullman Street Irvine, Ca. 92614 United States of America
More informationTable of Contents. Introduction Product Overview. Controller Features... Application... Installation and Operations.. 3.0
Table of Contents Introduction. 1.0 Product Overview. 2.0 Controller Features... 2.1 Application... 2.2 Installation and Operations.. 3.0 Location 3.1 System Design Basics.. 3.2 Well Measurements... 3.3
More informationInstallation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS
Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS www.icmsa.co.za PUMP SPECIFICATIONS Pump Model voltage (V) Power (W) Max Flow
More informationSUBMERSIBLE PUMPS
motralec rue Lavoisier. ZA Lavoisier. 5223 HERBLAY CEDEX Tel. : 1.3.7.65. / Fax. : 1.3.7.68 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com SUBMERSIBLE PUMPS - 6-8 INSTALLATION,
More informationContents INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...
Contents Page INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...6 BATTERY...7 CHARGE CONTROLLER...8 FUSE...8 TOWERS...8 INSTALLATIONS...9
More informationOWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS
FW0080 0511 Supersedes 0610 OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS IL0632 WARNING IMPORTANT SAFETY INSTRUCTIONS RULES FOR SAFE INSTALLATION
More information2 Wire Plus Ground 3 Wire Plus Ground IL0655
4 INCH SUBMERSIBLE WELL PUMP 2 & 3 Wire 2 Wire Plus Ground 3 Wire Plus Ground Español p. 21 For installation videos and other information, scan with your smart phone. Or, visit: starwatersystems.com and
More informationElectronic Products ELECTRONIC MAINTENANCE
SubDrive2W, 75, 100, 150, 300, MonoDrive, and MonoDrive XT Should an application or system problem occur, built-in diagnostics will protect the system. The FAULT light or digital display on the front of
More informationPWP - PWS Submersible Pumps INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION RECORD
PWP - PWS 4-6 - 8 Submersible Pumps INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION RECORD Date of Installation: Model Number: Serial Number: Depth of the Well: Depth of Water: Pump Setting: Wire
More informationSUBMERSIBLE ELECTROPUMPS 50 HZ
L.Nemitsas Ltd - Head Office P.O.Box 54436 3724 Limassol, Cyprus Tel: +357 25569225 & 25569226 Fax: +357 25 396955 L.Nemitsas Ltd - Nicosia Branch F.Tsigaridi 19 Str. 2235, Latsia - Nicosia Tel: +357-22467366
More informationSS/SSH Submersible Pump. Owner s Manual
Est. 1985 www.aquascience.net SS/SSH Submersible Pump Owner s Manual 4 SUBMERSIBLE PUMP INSTALLATION INSTRUCTIONS IMPORTANT: Read this manual carefully before installing or operating the pump. Review instructions
More information4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause
4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on
More informationInstallation & Operating Manual
Installation & Operating Manual 6 WS Series Submersible Turbine Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 6/11 Edition Its Quality is unsurpassed in material and workmanship
More informationInstallation & Operating Manual
Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been
More informationINSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT
AFP12-im -issue2-2017 INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT INTRODUCTION Thank you for purchasing a Macnaught 12 or 24 volt Electric Diesel Fuel Pump.
More informationInstallation Instructions
K-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in
More informationManual Installation & Operation
Manual Installation & Operation Model: NCxxLxx 12A or 30A Solid State Solar Charging Regulator and 12A Load Controller. 231 Patent #: 5,642,030 Applies Page 1 Warnings When Installing, connect grounds,
More informationPHOTO VOLTAIC CHARGE MODULE MULTI POINT TRACKING
FEATURES Multi Point Tracking (MPT)/ Pulse Width Modulation (PWM) is a six stage solar charge controller. Drop-in PWM replacement for the PVCM-25D two stage solar charge controller. Works with the PVDM4-LC,
More informationHALLMARK INDUSTRIES INC. Deep Well Submersible Pumps Operating & Installation Instructions
Deep Well Submersible Pumps Operating & Installation Instructions WARNING: Read the user s manual thoroughly before installing the pump! A 115V pump is for 115V (or 110V) power! A 230V pump is for 230V
More information2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.
0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect
More informationGeneral Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07
General Installation Manual for SANYO HIT Photovoltaic Modules. Please read this manual completely before use or installation of SANYO modules. This manual applies to the following models: HIP-205BA3,
More informationLS0512 Solar Charge Controller
LandStar LS0512 Solar Charge Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...
More informationAHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM
AHFP-im-issue2-2017 INSTRUCTION MANUAL AHFP70LPM AHFP100LPM AHFP150LPM INTRODUCTION Thank you for purchasing a Macnaught 240 volt electric diesel fuel pump The Macnaught range of 240 volt electric diesel
More informationAHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A
AHFP85L-im -issue2-2017 INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT INTRODUCTION Thank you for purchasing a Macnaught 12 volt High Flow
More informationInstallation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps
Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation
More informationTHERMO TECHNOLOGIES USDT 2005 Analog Differential Controller
Revision 3 THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express
More informationThe POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.
The POWER In PRESENTATION PRODUCTS Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137
More information255 Liter/Hr, In Tank Fuel Pump For Chrysler Front Wheel Drive Vehicles Catalog # INSTALLATION INSTRUCTIONS
255 Liter/Hr, In Tank Fuel Pump For 1984-1990 Chrysler Front Wheel Drive Vehicles Catalog # 17934 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before installing your new In-Tank
More information20W Polycrystalline Solar Panel
20W Polycrystalline Solar Panel User Manual WARNING: ead and understand all instructions, warnings, and cautions before using this product. Failure to follow the instructions, warnings, and cautions ay
More informationPrincipals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...
Priming Systems Installation Priming Systems Operation & Maintenance Form No. F 1031 Section 2312 Issue Date 10/07/94 Rev. Date 02/27/06 Table of Contents Illustrations Principals of Operation...........................
More informationRevision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide
Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information
More informationPL Submersible, Semi-Vortex, Water Feature Pump
TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and
More informationProduct Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526
Product HVS Series Cable Splice Shim Kit for 1/C Extruded Dielectric (Poly/EPR) Power Cables: Metallic Tape, Wire Shield, UniShield, LC Shield, Lead Sheath or Concentric Neutral URD Cables UniShield is
More informationSunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE
SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE Introduction This guide contains application and user safety information you should become familiar with before using your SWPB series
More informationFHOTON Drive. Installation Guide
FHOTON Drive Installation Guide 2 SUBDRIVE SOLAR INSTALLATION MANUAL TABLE OF CONTENTS Overview...5 Descriptions and Features...5 How it Works...6 Features...8 Installation...11 Controller Location Selection...
More informationINSTALLATION MANUAL THE / MODULE. IEC & UL version
INSTALLATION MANUAL IEC & UL version THE / MODULE Duomax Duomax Duomax M Plus TSM-PDG40.40 TSM-PDG40.47 TSM-PDG5.40 TSM-PDG5.47 TSM-PDG14.40 TSM-PDG14.47 TSM-PEG40.40 TSM-PEG40.47 TSM-PEG5.40 TSM-PEG5.47
More informationSunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE
SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE Introduction This guide contains application and user safety information you should become familiar with before using your SW/OEM
More information6TSP Series Radial Flow
OWNER S MANUAL Submersible Turbine Pumps 293 Wright Street, Delavan, WI 53115 Phone: 888-237-5353 Fax: 800-321-8793 Web Site: berkeleypumps.com 6TSP Series Radial Flow Installation/Operation/Parts For
More informationINSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR
INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR RED JACKET Extracta Remote Gasoline Pumps Models P75S17-3, P150S17-3 & X4P150S17 380 Volt, 3 Phase, 50 Hertz by 051-138 Rev. C ELECTRICAL SERVICE
More informationAPPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1
Table of Contents APPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1 B.01 SCOPE... B-1 B.02 GENERAL... B-1 B.03 ELECTRICAL QUALIFICATION... B-1 B.04 EQUIPMENT RECONDITIONING... B-2
More informationHydro-Sync Slide-Out System
Hydro-Sync Slide-Out System SERVICE MANUAL Rev: 08.14.2018 Hydro-Sync Slide-out System Service Manual TABLE OF CONTENTS Safety Information 3 Product Information 3 Operation 4 Extending Slide-Out Room 4
More informationThe Traveler Series: Adventurer
The Traveler Series: Adventurer RENOGY 30A Flush Mount Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.2 Important Safety Instructions Please save these instructions.
More informationGeneral Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.
General Installation Manual for SANYO HIT Photovoltaic Modules. Please read this manual completely before use of, or installation of HIT Power modules. This manual applies to the following models: HIT
More informationVADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY
PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system
More informationInstructions for MB832 Manual Barrier Ver0614
Instructions for MB832 Manual Barrier Ver0614 Read all the instructions before starting It is recommended that Locktite Blue brand thread sealant be used for all arm and pivot bolts as added protection
More informationPENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK
OWNER S MANUAL 6 Submersible Motors PENTEK XE-6 232852 DRINKING WATER SYSTEM COMPONENT ANSI/NSF 61-G 3RZE 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.PUMPS.COM PH: 1-866-9 PENTEK 2015 Pentair Ltd. All Rights
More informationInstallation Manual LIGHTWAY PV MODULES. Revision Date March 30, 2013 /Applicable for IEC certified products
LIGHTWAY PV MODULES Installation Manual Lightway Green New Energy Co.,Ltd. New Industry Park,Gaobeidian,Hebei Province,China Tel:0086-(0)312-2951177 Fax:0086-(0)312-2951166 www.lightwaysolar.com Thank
More informationService Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments
Service Manual For The X Ride 28 Rider Extractor Model XR28QP For: Training Troubleshooting Adjustments Contents 1 Cautions ------------------------------------------------------------------------------
More informationThe Traveler Series: Wanderer
The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.
More informationSLIMFLEX LED Tape Lighting
1 SLIMFLEX LED Tape Lighting Installation Guide BEFORE YOU BEGIN, READ INSTALLATION INSTRUCTIONS THOROUGHLY Install in accordance with the National Electric Code and local regulations This product is intended
More informationGeneral Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09
General Installation Manual General Installation Manual for SANYO HIT Photovoltaic Modules. Please read this manual completely before installation or use of SANYO modules. This manual applies to the following
More informationDankoff LCB Solar Pump & Fan Controller. INSTRUCTIONS For INSTALLATION and OPERATION
Dankoff LCB Solar Pump & Fan Controller INSTRUCTIONS For INSTALLATION and OPERATION Model DL-8B Model DL-16B Model DL-10B CUSTOM Models (8 amp, 12/24V) Item ISS-11065 (16 amp, 12/24V) Item ISS-11066 (10
More informationThe Traveler Series TM : Adventurer
The Traveler Series TM : Adventurer 30A PWM Flush Mount Charge Controller w/ LCD Display 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 3.4 Important Safety Instructions Please save
More informationLS0512R Solar Light Controller
LandStar LS0512R Solar Light Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...
More informationC802/C802D/C802TD/C820 Alternators Troubleshooting Guide
C802/C802D/C802TD/C820 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning
More informationYour new LM controller is a state-of-the art device which was developed in accordance with the latest
CAP LM-series Solar charge controller User Manual Thank you very much for buying this CAP product. Please read the instructions carefully and thoroughly before using the products. Your new LM controller
More informationUES-LL End Termination Kit
Installation Instructions UES-LL End Termination Kit for Series Long Line Heating Cables 1 PJ950 161-562681-022 July 2015 UES-LL End Termination Kit Kit Contents Item Qty Description Item Qty Description
More informationM-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual
SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2
More informationC.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values
C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information
More informationchannel damage the internal components and the weight may break the internal wiring or flexible strip.
YOU MAY NEED End cap Power adaptor Connector pin Splicing pin Connector Silicone glue Pliers Power converter Converter + surge protector Heat shrink Aluminium channel Heat gun NT cutter IMPORTANT NOTES
More informationInstallation and Instruction Manual. Cold Weather Starting Aid Part No A. Jet-Ex 4 Diesel Generator Sets
TO-211 121890 Installation and Instruction Manual for Cold Weather Starting Aid Part No. 489782A For Use With Jet-Ex 4 Diesel Generator Sets HOBART BROTHERS COMPANY Ground Power Division Troy, Ohio 45373
More informationPhotovoltaic Module User Manual
Photovoltaic Module User Manual Index of Contents: Overview... 1 Applicable Products... 1 Unpacking... 2 Preparation before Installation... 3 Installation and operation... 3 Wiring and Connection... 5
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationUser Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro
A. NOTICE User Guide BreezePro TPW-400DT 12/24V 400W Wind Turbine 1. This information is believed to be reliable; however, We assume no responsibility for inaccuracies or omissions. The user of this information
More informationC.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values
C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazard(s) of various risk levels or to important
More information8400JF (240V Single Phase) Aerating Fountain Specifications
8400JF (240V Single Phase) Aerating Fountain Specifications This specification is written and intended to provide bidders the necessary information pertaining to the floating aerating fountain(s) or surface
More informationELEC4 ELECTRONIC IGNITION KIT FITTING INSTRUCTIONS
ELEC4 ELECTRONIC IGNITION KIT FITTING INSTRUCTIONS This Ignitor electronic ignition kit is designed to be used on Silver Shadow and Bentley T models from VIN8742 to 22117 (approximately) fitted with a
More informationThe Traveler Series: Wanderer
The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This
More informationBattery Cables. Wire & Cable
Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,
More informationw w w. h d o n l i n e s h o p. d e HEATED HAND GRIP KITS GENERAL REMOVAL -J02983 REV Kit Number Models Kit numbers Service Parts
-J098 REV. 007-0-0 GENERAL Kit Number 56047-0B, 5607-0B, 5674-0B, 5696-0B, 565-0B, 5669-0A, 56694-04A, 56750-04A, 5688-0A, 569-05, 5696-05, 56997-07 Models For model fitment information, please see the
More informationDFS Dynamic Fuel Systems Inc.
DFS Dynamic Fuel Systems Inc. Dynami c Fuel System s Inc. Diesel Magnum US PAT# 7100582 Installation Manual Diesel Magnum US PAT# 7100582 Installation Manual Ver 52.1 www.dynamicfs.com www.fireemup.com
More informationSUBMERSIBLE PUMP HSE RANGE
SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2
More informationOwner s Manual. Expansion Kits: GP-RV-80E GP-RV-95E GP-RV-160E
powered by Expansion Kits: GP-RV-8E GP-RV-E RV Power Kits: GP-RV-8 GP-RV- Weekender SW Owner s Manual shown here GP-RV-8E GP-RV-E GP-RV-8 GP-RV- Standard Kits Expansion Kits PART GP-RV-8/95/ * or SW *
More informationPump Installation & Service Manual
unc S entric TM Pump Installation & Service Manual Please record your MODEL # SERIAL # and for your application: Volts Amps Thank you for purchasing the Dankoff SunCentric water pump. This pump has been
More informationElectric Fuel Pump FPM
INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.
More informationINSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB
INSTALLATION MANUAL The Solution in Black The Comax Solution The Quadmax Solution The Universal Solution The Aesthetic Solution The Utility Solution The Honey Module IEC version TSM_IEC_IM_2012_RevB Table
More informationSUBMERSIBLE PUMP HSE RANGE
SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806 SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2
More informationComponents for your PV Solar Electric System
Components for your PV Solar Electric System Here is a brief description of the major components of a Solar Electric System. The components vary depending on whether batteries will be used in your system.
More informationSubmersible Mixed Flow/Axial Flow Pump Model SAM Model SPM
Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial
More informationELECTRICAL. Contents - Wiring Diagrams
Contents - Wiring Diagrams T-Bar (Floating Deck - Hydro)............................................ 8-16 T-Bar (Fixed Deck - Gear)............................................... 8-17 T-Bar (Fixed Deck
More informationC Power Connection Kit
1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is
More informationINSTALLATION MANUAL.
INSTALLATION MANUAL D6M_BxA Series : D6M_B1A / D6M_B2A / D6M_B3A / D6M_B5A D6M_AxA Series : D6M_A1A / D6M_A2A / D6M_A3A / D6M_A5A D6P_BxA Series : D6P_B1A / D6P_B2A / D6P_B3A / D6P_B5A D6P_AxA Series :
More informationInstallation and Commissioning of Auxiliary Power Unit
Models PC6012 PC6013 PC6014 PC6015 PC6022 PC6023 PC6024 Installation and Commissioning of Auxiliary Power Unit 30-871-21 Rev. E Warning & Cautions Vehicles with longer wheel bases should have the APU mounted
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or
More informationDSP 200 Pump Controller Instruction Manual Instructions for Installation and Operation
DSP 200 Pump Controller Instruction Manual Instructions for Installation and Operation CAUTION! READ ALL INSTRUCTIONS PRIOR TO INSTALLING OR USING THIS EQUIPMENT The DSP 200 and the entirety of this document
More informationk. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.
General Troubleshooting Charts General Troubleshooting Charts Use the charts on the following pages to help in listing all the possible causes of trouble when you begin diagnosing and testing of a machine.
More informationSPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions
SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P with Pyrotenax MI heating cable using required MI cable grounding kit SPC-P with Raychem
More informationThe Solar Power Kit includes the following components. Please be sure you have all listed components before beginning. 5/16" x 2" Carriage Bolt
Solar Power Kit For Cabled Weather Stations This manual describes how to install and use the Solar Power Kit. The Solar Power Kit enables cabled stations, cabled Weather Envoys to be stand-alone units,
More informationOwner s Manual. LTS Hide-A-Way Truck Side Gate
Owner s Manual LTS Hide-A-Way Truck Side Gate 10900 Kenwood Road Cincinnati, OH 45242 Ph: 513-891-6210 Toll-Free: 866-539-6261 Fax: 513-891-4901 www.leymanlift.com sales@leymanlift.com LML00410-11/6/15
More informationSTANDARD FEATURES: TRINE 3000 SERIES ELECTRIC RELEASES: RECOMMENDED INSTALLATION SEQUENCE: FINISHES:
1440 Ferris Place Bronx New York 104613699 TRINE 3000 SERIES ELECTRIC RELEASES: Congratulations on the purchase of this quality TRINE security product. This product has been designed to install easily,
More informationRSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English
f Commercial Rapid Shutdown Combiner RSDCOM Installation and Operation Guide Models: RSDCOM M-PC-1Z-4F RSDCOM M-PC-1Z-4F-24V RSDCOM M-PC-1Z-5F RSDCOM M-PC-1Z-5F-24V RSDCOM M-FG-2Z-4F RSDCOM M-FG-2Z-4F-24V
More informationHELIOMOTION QUICK ASSEMBLY GUIDE PV-650
HELIOMOTION QUICK ASSEMBLY GUIDE PV-650 PART I - FOUNDATION M16 M16 8x 2 PLACEMENT 1m Area around flange must be clear of obstacles in a 1 meter radius. Place the unit in a location that receives sunlight
More informationEMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions
EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating
More informationExterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation
Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview
More informationPS4000 HR/C SOLAR-OPERATED SUBMERSIBLE PUMP SYSTEMS MANUAL FOR INSTALLATION, OPERATION, SERVICE. Sun. Water. Life.
Failure to follow these instructions will void the warranty. SOLAR-OPERATED SUBMERSIBLE PUMP SYSTEMS PS4000 HR/C MANUAL FOR INSTALLATION, OPERATION, SERVICE LORENTZ Pump Systems PS4000 HR/C Manual v110131
More informationMODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationThe POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.
The POWER In PRESENTATION PRODUCTS Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737
More information