Genquip Gi3300ER DSP Inverter Generator. Owner s Manual GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 1

Size: px
Start display at page:

Download "Genquip Gi3300ER DSP Inverter Generator. Owner s Manual GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 1"

Transcription

1 Genquip Gi3300ER DSP Inverter Generator Owner s Manual GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 1

2

3 Table of Contents Control Function 4 Pre-Operation Checklist 5 Fuel System Refuelling & Fuel Level Gauge Engine Oil Control Function 6 Oil Warning System Engine Switch DC Protector Operation 7 Starting the engine Remote start/stop function AC connection overload indicator Charging Batteries Battery Periodic Maintenance 11 Spark Plug Inspection & Oil Replacement 12 Engine Oil Replacement 13 Air Filter Maintenance 14 Valve Adjustment 15 Genquip Safety Operating Procedure & Cleaning 19 Visual Inspection Start Up Shutdown Cleaning Storage, Transportation & Servicing 20 Troubleshooting Engine Won t Start Generator Stops Wiring Diagram 24 Specifications & Dimensions 25 Warranty 26 Fuel Filter 14 Fuel Tank Filter 14 GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 3

4 Control Function (Remote Start Model) Control Panel Key and Description (Electric Start Model) 1. Carry Handles 2. Fuel Level Gauge 3. Fuel Cap and Vent 4. Fuel On and Off Switch 5. AC Ready Pilot Light 6. Oil Warming Light 7. Ground (Earth) Terminal Volt Sockets 9. Engine On and Off Switch 10. Recoil Stater 11. Transport Handle V DC Outlet and Reset Button 13. Access Door Panel 14. Electric Key Start PAGE 4 GENQUIP GI3300ER DSP INVERTER GENERATOR

5 Pre-Operation Checklist Note: Pre-operation checks should be carried out each time the generator is used. Fuel System Make sure there is sufficient fuel in the tank. The engine uses regular unleaded petrol only. The fuel tank capacity is 7 litres. Refuelling & Fuel Level Gauge To refuel, remove cap and fuel slowly until fuel gauge indicates full. Apply fuel cap. Fuel Cap Fuel Level Gauge F E Full Empty WARNING: Fuel is high flammable and poisonous. DO NOT fill above the top of fuel filler or it may overflow when the fuel heats up and expands. Wipe up any spilled fuel immediately. After refuelling, make sure the tank cap is tightened. Engine Oil Make sure the engine oil is at the upper level of the oil filler hole. Add oil as necessary. Recommended oil for most climates is 10W30. Engine oil quantity is 600 millilitres. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 5

6 Control Function Oil Warning System If the oil level falls below the safe operating level, the engine will stop automatically. Unless you refill with oil, the engine will not start again. Note: If the engine stalls or does not start, turn the engine switch to ON position and then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil is low. Add oil and restart. Engine Switch The engine switch controls the ignition system. A. Ignition circuit is switched on. The engine can be started. S TO P O N A B. Ignition circuit is switched off. The engine will not run. B DC Protector The DC Protector turns off automatically when the load exceeds the generator s rated output. ON OFF (PUSH) PROTECTOR Note: If the DC Protector trips to the OFF position, press to reset. Reduce the load to the specified generator output if the DC protector turns off. If it turns off again, consult the authorized dealer. PAGE 6 GENQUIP GI3300ER DSP INVERTER GENERATOR

7 Operation Starting The Engine Note: Before starting the engine, do not connect any electric devices. 1. Turn the fuel switch lever to the ON position. 2. Turn the engine switch to the ON position... O O O O GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 7

8 Remote Start/Stop Function 1. Turn the fuel knob to On. 2. Turn the engine switch to On. 3. To start the engine remotely, push unlock button on the remote. If the first attempt fails, push the unlock button again. 4. To shut off the generator, push the lock button on the remote. 5. If the generator will not be used again for more than a day, turn the engine switch to the Off position. Failure to turn the engine switch off after use will drain the battery. PAGE 8 GENQUIP GI3300ER DSP INVERTER GENERATOR

9 Operation (Electric Start Model) AC connection overload indicator light The overload indicator light (the AC pilot light) will flash when an overload of connected electrical device is detected or the inverter control unit overheats. The electronic breaker will then activate, stopping power generation in order to protect the generator and any connected electric devices, but the engine will not stop running. When the overload indicator light comes on and power generation stops, proceed as directed: 1. Turn off any connected electric devices and stop the engine. 2. Reduce the total wattage of connected electric devices within the application range. 3. Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove. 4. After checking, restart the engine. The short term peak load is 3,300 watts and the max operating load is 3,000 watts. High temperatures or high elevations will reduce the expected performance of this generator. NOTE! The generator s AC output automatically resets when the engine is stopped and restarted. Using the generator for battery charging CAUTION! Do not use AC and DC power at the same time or the generator may be damaged. The generator DC rated voltage is 12V. 1. Start Engine 2. Plug in battery charge wires to DC receptacle (#12 on Control Function diagram) NOTE! Make connections to the battery after starting the engine. Clamp the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. Do not reverse these positions. Use of the 12V (DC) outlet whilst charging batteries must be closely monitored as the output is continuous & cannot be regulated. The 12V (DC) outlet fitted to this generator is NOT a battery charger. Do not use AC (240V) and DC(12V) power at the same time as damage to the control unit will occur resulting in warranty being voided. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 9

10 Battery This generator is equipped with a sealed type (MF) battery, which does not require any maintenance. There is no need to check the electrolyte or to add distilled water. Battery connection 1. Open the front access door panel. 2. Check the positive lead (red) connection to the positive (+) terminal. 3. Connect the negative lead (black) to the negative (-) terminal. 4. Close the front access door panel. To charge the battery Have your Genquip dealer or an qualified electrician charge the battery as soon as possible if it seems to have discharged. Recommended battery Capacity: 12V/4.5Ah or 12V/5Ah Size: (LxWxH): 90x70x102mm Battery disconnections 1. Disconnect the negative lead (black) first, then the positive lead (red) from the battery. 2. Connect the positive lead (red) first, then the negative lead (black) to the battery when installing the battery. + - CAUTION Do not connect negative battery cable until you start to use the machine! PAGE 10 GENQUIP GI3300ER DSP INVERTER GENERATOR

11 Periodic Maintenance Item Spark Plug Attention 1. Clean Adjust 2. Replace Pre-operation (Daily) 1 Month or 20 hours 3 Months or 50 hours 6 Months or 100 hours 12 Months or 200 hours 1 2 Valve Clearance Check Adjust Engine Oil Air Cleaner 1. Check 2. Replace 1. Check 2. Replace 1 2* 2* * * Fuel Filter Replace Clean Spark Arrester-Screen Recoil Starter Check operation Choke Handle Check operation Fuel System Check hose condition look for leaks Fittings Fasteners Check and tighten Cooling System (Air) Check for obstructions Exhaust System Check for obstructions * First 20 hours & then every 50 hours GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 11

12 Spark Plug Inspection & Oil Replacement You should periodically remove and inspect the spark plug. 1. Check for discoloration and remove the carbon. 2. Check the spark plug type and gap. Standard electrode color: tan colour Standard Spark Plug: BPR4ES(NGK)(F7RTC) Gap: ( inches) 3. Install the spark plug. Spark Plug Torque:14 lbs. -Ft. ( inch) PAGE 12 GENQUIP GI3300ER DSP INVERTER GENERATOR

13 Engine Oil Replacement 1. Place the machine on a level surface. Warm up the engine, then stop the engine. 2. Remove the rubber cap on the bottom. 3. Place an oil pan under the engine. Remove the drain bolt. 4. Open the oil filler cover as shown and remove the oil filler cap so that the oil can be completely drained. 5. Check the drain bolt, gasket, oil filler gap and O-ring. 6. Reinstall the oil drain bolt - drain bolt torque: 12 Ft. lbs. 7. Add engine oil to the upper level. Recommended oil for most climates: 10W30 Engine Oil Quantity: 600 millilitres CAUTION: Be sure no foreign material enters the crankcase. 8. Install the oil filler cap. 9. Install the rubber cap on the bottom. CAUTION: Be sure to replace cap securely to prevent from falling off during operation. 10. Close the oil filler cover. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 13

14 Fuel Filter Do not smoke or have an open flame in the vicinity of the fuel and solvent. 1. Stop the engine. 2 Clamp the fuel line with the clip. 3 Replace the fuel filter. Fuel Tank Filter 1. Remove the fuel tank cap and filter. 2. Clean the filter with solvent. If damaged, replace. 3. Wipe the filter and insert it. Be sure the tank cap is securely tightened. Air Filter Maintenance 1. Remove black side cover (4 screws, opposite exhaust outlet side) 2. Unscrew bolts 3. Remove cover 4. Remove foam air filter 5. Clean filter in foam filter cleaner and dry 6. Re-oil with filter oil 7. Squeeze out excess oil. Do not wring filter out 8. Return to machine and reassemble. PAGE 14 GENQUIP GI3300ER DSP INVERTER GENERATOR

15 Valve Adjustment Note: Valve adjustment should only be performed on a cool engine. 1. Remove back case, then take off valve cover. 2. Pull the starter rope gently and set the piston in top dead centre. Use a stick in the spark plug hole measure the depth. 3. Insert a feeler gauge into the gap between rocker and valve to measure the valve clearance. Valve Clearance Intake: 0.1mm (0.004 in) Exhaust: 0.1mm (0.004in) 4. If adjustment is necessary, proceed as follows: a. Hold rocker axis using the wrench and loosen the lock nut. b. Loosen the lock nut of rocker axis to gain the specified intake and exhaust valve clearance. c. Hold rocker axis using a wrench and tighten the lock nut. d. Check the clearance of valve after adjustment. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 15

16 Genquip Safety Genquip values your safety and the safety of others when using your Genquip generator General safety It is important to read and understand your owner s manual before operating your Genquip generator. Tips for safe operation Know where the controls are and how they operate the startup and shut off procedures. Know the location of the fuel shutoff and how to operate it. Always user your Genquip generators in a well ventilated area. Be aware your Genquip generator is not weatherproof. Ensure your generator is properly grounded to prevent electrical shock. Operate the generator on a level surface. Never refuel your Genquip generator whilst the engine is running. Always allow sufficient time for the generator to cool down before refueling. Always refuel the generator in a well-ventilated area. Keep all flammable materials and fuel away from the operating generator. Always locate your generator where its exhaust will vent safely. Hot exhaust from a generator can easily start a fire. Avoid getting burned. Many generator parts radiate heat that is sufficient to burn you during operation. Only use a licensed electrician to hard wire your Genquip generator. Turn off all equipment powered by the generator before shutting it down your generator. Never overload your Genquip generator. If unsure about the power requirements, consult a licensed electrician. Wear appropriate ear protection. Generators can be noisy. Keep children away from your Genquip generator at all times. Never permit anyone to operate a Genquip generator without proper instructions. DANGER: Only competent and qualified electricians should connect wiring to this equipment; all connections must comply with all applicable Australian Standards and electrical codes. PAGE 16 GENQUIP GI3300ER DSP INVERTER GENERATOR

17 Activity/Procedure If you do this... Potential Hazards This could happen... Risk Corrective Action You can prevent by... Operating generator in an unventilated or enclosed area. Generator may over heat. Toxic engine exhaust may cause Carbon Monoxide (CO) poisoning 2 1 Operate generator in a well-ventilated area. Do not operate in an enclosed location. Operate the generator in a careless/reckless manner. Unsafe operation could lead to serious injury to you & others. 2 Review and understand all the operating instructions and warnings supplied by manufacture Refueling the generator while engine is running. Over filling with fuel or fuel spillage while refueling. Tampering with the factory preset engine settings. Petrol vapors are highly flammable & could cause a fire or explosion, which can cause serious injury. Fuel that is spilled whilst refueling can cause fire or explosion. Generator could overheat and engine could overspeed, which may result in a fire causing injury. 2 Always shut down engine and allow engine to cool sufficiently. Open fuel cap slowly and have an appropriate fire extinguisher present. 2 Open fuel cap slowly. Do not over fill fuel tank. If fuel spillage has occurred during refueling, clean the spillage completely and allow sufficient time for any fuel vapors to dissipate. 2 Never tamper with factory settings. If in doubt contact Genquip. Failure to use the generator grounding point and correctly ground the generator. Generator unit could become electrically charged and could cause electrocution. 1 Make sure the generator is connected /grounded correctly. Exceeding the load capacity of the generator by attaching to many items, or items with very high load ratings. Could overheat some items or their attached wiring causing fire or electrical shock. 1 2 Understand load ratings. Make sure that the total of electrical loads for all attachments does not exceed the load rating of the generator. Refer to a licensed electrician if in doubt. Operating generator with guards or protective covers removed. Exposed moving parts and hot surfaces could cause injury. 2 Never operate the generator without the factory fitted guards or protective covers. Risk numbers are 1. fatal or permant disability and 2. serious injury or long term illness. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 17

18 Activity/Procedure If you do this... Potential Hazards This could happen... Risk Corrective Action You can prevent by... Contact with hot surfaces such as engine, exhaust components. Could result in serious burns. 2 During operation, touch only the control surfaces. Shutting the generator down and letting it cool sufficiently. Keep children away from generator during and immediately after operation. Operating generator to close to buildings or placing objects close to the muffler exhaust can cause. Smoking around the generator. Heat buildup that could cause generator to overheat and the possibility of fire. Objects close to generator may be damaged due to close proximity. Fire. Explosion. Serious Injury. 2 Ensure that the generator is sufficient distance from buildings or objects allowing heat and exhaust emissions to dissipate freely. 2 Do not smoke around the generator under any circumstances. Operating whilst wet or Cleaning the generator when in operation can cause. Electrocution. 1 Never operate the generator whilst wet or expose to damp conditions. Clean the generator only when shut down and cooled down completely. Do not spray water directly on or near any electrical items. Use a damp cloth to Wipe over generator to keep clean. Operating generator on an uneven surface may cause. Moving the generator whilst in operation. Transporting generator. Using the incorrect fuel &/or oil type. Engine to seize and over heat due to improper lubrication. Fuel spillage, which may cause fire or explosion resulting in serious injury. Fuel spillage, which may cause fire or explosion resulting in serious injury. Fuel spillage, which may cause fire or explosion resulting in serious injury. Oil spillage, which may cause slippage. Misfiring of engine, which may result in engine parts separating from main body resulting in serious injury. 2 Always operate generator on a level & hard surface. 2 Always shut down generator and allow it to cool completely before moving. 2 Ensure fuel tap is switched off and the fuel cap is affixed firmly. Always transport the generator in an upright position. If transporting over a long distance drain fuel from tanks. 2 Ensure you check that you are using correct oil and fuel types. PAGE 18 GENQUIP GI3300ER DSP INVERTER GENERATOR

19 Genquip Operating Procedure & Cleaning Visual Inspection Carefully inspect the generator set before you first use it. Look for the following: General appearance and cleanliness Loose or broken wires and defective connections Oil or fuel pooling around generator Check fuel filter Missing covers Oil level Fuel level Air filter is not dusted and is free of dust and debris Generator is grounded Fuel cap is on Start Up Disconnect any electrical devices from the generator. Make sure the generator is on a level surface. Check the exhaust is free from obstructions. Check the fuel shut tap is on. Always use fresh fuel. Check the engine switch is in the ON position. Check the choke is in the open position. Return choke to the closed position once running (petrol model only). Shutdown Make sure all electrical devices, are disconnected from generator. Turn the fuel tap to the OFF position. Allow the generator to cool before moving or storing. Cleaning Keep the generator set clean and free of foreign material. Clean generator at least once monthly. A soft brush may be used to loosen caked-on dirt. Use a soft, damp cloth to wipe away loose dirt. To clean dirt from hidden or remote areas of the unit, use a dry, filtered, low pressure air or vacuum system. CAUTION: DO NOT use a forceful spray of water to clean the generator. Water can penetrate generator s electrical system, which could reduce insulation resistance. Possible generator failure may result. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 19

20 Storage, Transportation & Servicing Long term storage and transportation of your machine will require preventive procedures to guard against deterioration. Drain The Fuel 1. Remove the fuel tank cap. Drain the fuel tank into an approved gasoline container using a commercially available hand siphon. Then, replace the fuel tank cap. WARNING: Fuel is highly flammable and poisonous. Wipe up any spilled fuel immediately. 2. Drain fuel from the carburettor by loosening the drain screw on the carburettor float chamber. 3. Turn the fuel cock lever to OFF. Start the engine and leave it running until it stops. This will burn any remaining fuel in the carburettor. Engine 1. Remove the spark plug. Pour about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug. Turn over engine several times (with ignition off) to coat the cylinder walls with oil. 2. Pull the recoil starter until you feel compression, then stop pulling. This prevents the cylinder and valves from rusting. 3. Clean exterior of the generator. 4. Store the generator in a dry, well- ventilated place, with the cover placed over it. 5. The generator must remain in a vertical position when stored, carried or operated. Servicing First service - 20 hours. Service intervals thereafter - 50 hours. If operating in hot dusty conditions, oil and air filters must be checked daily and service intervals should be every 10 hours initially and every 25 hours thereafter. PAGE 20 GENQUIP GI3300ER DSP INVERTER GENERATOR

21 Troubleshooting TROUBLE POSSIBLE CAUSE SUGGESTED REMEDY Engine will not start Low on fuel or oil content. Add fuel or oil. Ignition switch in OFF position. Faulty spark plug. Choke in wrong position. Unit loaded during startup. Spark plug lead loose/ disconnected. Unit may be flooded. Old fuel. Turn to ON position. Replace spark plug. Adjust choke accordingly. Remove load from unit. Disconnect the spark plug lead and reattach spark plug lead. Leave the generator to rest for 5-10 minutes and then try again, following the instructions when doing so. Alternatively, if the choke lever is in full choke position (start), switch the choke to the RUN position and try to re-start. Remove the existing fuel and replace with new fuel. AC power supply - No electrical output Faulty receptacle. Is the green LED on with motor running and no output? Is the red overload LED on? Have service centre replace receptacle. YES - Try another appliance that is known to work. Reduce the load if required. NO - Organise for the unit to be serviced. If it is - reduce the load. Faulty power cord. Replace cord. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 21

22 Troubleshooting TROUBLE POSSIBLE CAUSE SUGGESTED REMEDY DC power supply - No electrical output DC circuit breaker continually tripping Generator overheating Generator stops Circuit breaker kicked out (DC only). Overloaded. Faulty cords or equipment. Incorrect cables used. Mixed polarity. Generator overloaded. Insufficient ventilation. Generator may have fallen over. Generator may have run out of oil. Generator may have run out of fuel. Depress the reset button to rest the circuit breaker. Reduce load. Check for damaged, bare, or frayed wires on equipment. Replace. Check you are using the DC cables supplied with the actual generator. Using the incorrect cables could result in crossed polarity. Only use the supplied DC cables with the generator. Check the DC cables are connected to the correct battery polarity terminals. That is positive (+) to positive (+) and negative (-) to negative (-). Reduce load. Move to adequate supply of fresh air. Check to make sure that the generator is in it s correct upright position. If not take corrective action to put it in the upright position Check the generator has oil in it. If not, top up the oil tank. Check that the generator has fuel in it. If not, top up the fuel tank. PAGE 22 GENQUIP GI3300ER DSP INVERTER GENERATOR

23 Troubleshooting TROUBLE POSSIBLE CAUSE SUGGESTED REMEDY Generator stops (continued) Generator running rough Appliance is not working or stops working Generator may not be correctly ventilated with free flowing air. Generator fuel cap breather is in the closed position. Generator air filter may need cleaning. Generator fuel filter may be blocked. Choke may not be in the RUN position. The generator may contain old fuel that has been sitting still for a while. Unplug the appliance from the generator and check for defect. Check that the generator is located in an appropriately ventilated environment. If not, relocate the generator to a well-ventilated location. Check that the generator fuel cap has the breather switch in the "ON" position, allowing air to mix with the fuel. If the breather switch is located in the "OFF position, rotate switch to the "ON" position. Remove the air filter. Check that the air filter is clean. If required clean, dry and re-install the air filter. The internal in-line filter may be blocked. Contact your service agent for a service/replacement of the fuel filter. Check that the choke has been elevated to the RUN position. If not, elevate the choke to the RUN position. Drain the old fuel and replace with fresh fuel. If appliance has a defect follow the instructions as per the operation/owners manual. GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 23

24 Wiring Diagram (Electric Start Model) Wiring Diagram Colour Code, Key and Description (Electric Start Model) B G L O R W Y P B/W G/Y W/L Black Green Blue Orange Red White Yellow Pink Black & White Green & Yellow White & Blue 1. Main coil 2. Sub coil 3. Control unit 4. AC indicator light/ Overload indicator light 5. AC receptacle 6. Ground (Earth) terminal 7. Economy Control Switch 8. Step Motor controller 9. Engine switch 10. Oil warning light 11. Oil warning unit 12. Oil level gauge 13. Ignition coil 14. Spark plug 15. AC-CDI unit 16. Pulsar coil 17. Stepping motor 18. Charge coil 19. DC receptacle 20. Ballast PAGE 24 GENQUIP GI3300ER DSP INVERTER GENERATOR

25 Specifications & Dimensions GENERAL OVERALL LENGTH OVERALL WIDTH OVERALL HEIGHT DRY WEIGHT GROSS WEIGHT FUEL TANK CAPACITY NOISE LEVEL 585mm 420mm 470mm 37kg 39kg 7 litres db (at 7 metres) GENERATOR TYPE AC OUTPUT, Multistage permanent-magnet generator RATED OUTPUT 3000 watts MAX OUTPUT 3300 watts FULL TANK OUTPUT watts RUN TIME AT 1/2 RATED LOAD 8.5 hours RUN TIME AT RATED LOAD 4.5 hours POWER CONVERSION RATE 85-92% RATED VOLTAGE 240V RATED FREQUENCY 50Hz RATED CURRENT 13A DC OUTPUT 12V/8A ENGINE TYPE STARTING SYSTEM CYLINDER ARRANGEMENT BORE X STROKE IGNITION SYSTEM SPARK PLUG TYPE GAP DISPLACEMENT RATED OUTPUT FUEL ENGINE OIL QUANTITY 166F, OHV, AIR-COOLED, 4 - STROKE RECOIL START / ELECTRIC START INCLINED, SINGLE CYLINDER 66mm X 50mm CDI BPR4ES (NGK) / F7RTC 0.8 ( ) inches 171cc 4.9HP at 3600 r/min Unleaded Petrol 600ml GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 25

26 Gi - Series Digital Inverter Generator Warranty WARRANTY PERIOD The generator is covered under warranty for a period of: Domestic Use - 2 years from the original date of purchase or 500 hours use of the generator (whichever occurs first). Commercial Use - 1 year from the original date of purchase or 500 hours use of the generator (whichever occurs first). Use of the generator as a demonstration model or in a rental fleet will be considered commercial use. TERMS OF WARRANTY The applicable warranty period commences on the original date of purchase and does not recommence upon the replacement of any individual part. Individual parts replaced at any point during the applicable warranty period are only covered for the balance of the applicable warranty period. Warranty excludes normal wear items such as spark plugs and filters. Warranty will only apply if the generator is operated and maintained according to the conditions set out in the Owner s Manual and/ or Risk Assessment Report. Premature wear or damage which has, for example, been caused by dirt, dust or other abrasive material that has entered the generator due to improper maintenance, is not covered under warranty. Warranty only applies to the original purchaser and is not transferable. Original proof of purchase is required to be provided with any warranty claim. Irrespective of whether a warranty claim is approved or rejected, the following costs are not covered under warranty: freight, car hire, hire or loan equipment, loss of earnings or stock, fares, charter fares, tolls or medication. VOIDING OF WARRANTY Warranty will be voided in the following conditions: 1. Damage to generator caused by not operating or maintaining the generator according to the Owner s Manual and/or Risk Assessment report. 2. Damage to engine caused by operating engine with no oil, insufficient oil, incorrect oil grade or contaminated oil. 3. Damage to engine caused by use of alternate or contaminated fuel. 4. Damage to engine parts caused by contamination which has entered the engine due to improper air cleaner maintenance or reassembly. 5. Damage to engine caused by overheating due to foreign material clogging cooling fins and flywheel area or operating in a confined area. 6. Damage caused by alteration or modification of generator. 7. Serial number of generator does not correspond with our records. 8. Not allowing the dealer to inspect generator subject to warranty claim. FAULTY Should you believe the generator you purchase is faulty and is within the applicable warranty period you should contact us immediately to ascertain whether the generator is faulty. If a resolution to the problem cannot be determined, you will be issued with a Return Authorization (RA) Number. Your original proof of purchase will be required. The customer is entitled to all the rights and warranties implied by the Trade Practices Act 1974, provided that, to the extent that the Trade Practices Act 1974 permits Genquip to limit its liability for a breach of any such right or warranty, then Genquip s liability for such breach, including any consequential loss which the customer may sustain or incur, will be limited to, at Genquip s option, repair of the generator, replacement of the generator or, should a replacement be unavailable, a credit of the original purchase price of the generator. TRANSPORTATION COSTS The customer will be responsible for all transportation costs associated with the return of the generator to Genquip, although Genquip will assist the customer at its discretion to organise the transportation in the quickest and cheapest way possible. PAGE 26 GENQUIP GI3300ER DSP INVERTER GENERATOR

27

28 Genquip Warehouse 45 Riverside Road Chipping Norton NSW Call

Genquip Gi2000 Digital Inverter Petrol Generator. Owner s Manual

Genquip Gi2000 Digital Inverter Petrol Generator. Owner s Manual Owner s Manual page 1 Notes page 2 Table of Contents Control Function 4 Pre-Operation Checklist 5 Fuel System Check Fuel Level Control Function Continued 6 Engine Oil Oil Warning System Engine Switch DC

More information

Genquip Gi1000 Digital Inverter Petrol Generator. Owners Manual

Genquip Gi1000 Digital Inverter Petrol Generator. Owners Manual Owners Manual page 1 Notes page 2 Table of Contents Control Function 4 Pre Operation Checklist 5 Fuel System Check Fuel Level Control Function 6 Engine Oil Oil Warning System Engine Switch DC Protector

More information

Genquip Gi3300 DSP Inverter Generator. Owners Manual

Genquip Gi3300 DSP Inverter Generator. Owners Manual Owners Manual page 1 page 2 Table of Contents Control Function 4 Pre Operation Checklist 5 Fuel System efueling & Fuel Level Gauge Engine Oil Control Function Continued 6 Oil Warning System Engine Switch

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

Gasoline Inverter Generator

Gasoline Inverter Generator user manual Gasoline Inverter Generator table of contents Preface Introduction... Safety Information Exhaust fumes are poisonous... Fuel is highly flammable and poisonous... Engine and muffler may be hot...

More information

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. WARRANTY & SERVICE INFORMATION 1-YEAR LIMITED WARRANTY FOR THIS 950W

More information

1100W PORTABLE GENERATOR

1100W PORTABLE GENERATOR 1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use

More information

720W PORTABLE GENERATOR

720W PORTABLE GENERATOR 720W PORTABLE GENERATOR MODEL NO: G720 PART NO: 8857800 OPERATION & MAINTENANCE INSTRUCTIONS LS0214 INTRODUCTION Thank you for purchasing this CLARKE 720W Portable Generator Before attempting to use this

More information

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413 GENERATOR MODEL NO: FG3005 PART NO: 8857707 OPERATION & MAINTENANCE INSTRUCTIONS LS0413 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

LDG6000SA DIESEL GENERATOR OWNERS MANUAL LDG6000SA DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY Preface Thank-you for purchasing this generator. This operation manual contains information

More information

3kW GENERATOR. Owner s Manual

3kW GENERATOR. Owner s Manual 3kW GENERATOR SILENT INVERTER GASOLINE ENGINE GENERATOR Owner s Manual ORIGINAL INSTRUCTION Thank you for choosing a silent inverter gasoline engine generator set of our company. This manual contains

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING

More information

AG-HA-2500N GASOLINE GENERATOR

AG-HA-2500N GASOLINE GENERATOR AG-HA-2500N GASOLINE GENERATOR OWNER S MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY (I)WARNING 1. Read the operator s instruction manual. 2. Attention! Exhaust gases

More information

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609 GENERATOR MODEL NO: FG3000 PART NO: 8857700 OPERATION & MAINTENANCE INSTRUCTIONS LS0609 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION.

YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION. YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION. PREFACE Thank you for purchasing YANGKE generator. This manual covers

More information

PORTABLE INVERTER GENERATOR MODEL

PORTABLE INVERTER GENERATOR MODEL 3200Watts PORTABLE INVERTER GENERATOR MODEL #104612 Operation Manual This safety alert symbol identifies important safety messages in this manual. Failure to follow this important safety information may

More information

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E TDG8000-3 TDG7000SE-3 TDG7000E TDG8000E TDGW7000SE TDG7000E3 TDGW8000E

More information

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: 8877100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0217 INTRODUCTION Thank you for purchasing

More information

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616 5.5KVA GENERATOR MODEL NO: PG6500DVES PART NO: 8857810 OPERATION & MAINTENANCE INSTRUCTIONS LS0616 INTRODUCTION Thank you for purchasing this CLARKE 5.5KVA Generator. Before attempting to use this product,

More information

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114 GENERATOR MODEL NO: FG2500 PART NO: 8857727 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV 3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV PART NO: 8857815 OPERATION & MAINTENANCE INSTRUCTIONS LS1016 INTRODUCTION Thank you for purchasing this CLARKE 3KVA Dual Voltage Generator. Before attempting

More information

GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

KNOW YOUR AU4i... 2 INTRODUCTION... 3 SAFETY INSTRUCTIONS... 3 ELECTRICAL SAFETY... 3 USING AN EXTENSION CABLE... 4 SAFETY WARNINGS...

KNOW YOUR AU4i... 2 INTRODUCTION... 3 SAFETY INSTRUCTIONS... 3 ELECTRICAL SAFETY... 3 USING AN EXTENSION CABLE... 4 SAFETY WARNINGS... CONTENTS KNOW YOUR AU4i... 2 INTRODUCTION... 3 SAFETY INSTRUCTIONS... 3 ELECTRICAL SAFETY... 3 USING AN EXTENSION CABLE... 4 SAFETY WARNINGS... 4 PREVENTION OF ELECTROCUTION AND FIRE... 6 BEFORE USING

More information

950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS. MODELS #104609, # and #

950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS. MODELS #104609, # and # 950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS MODELS #104609, #104610 and #104611 Operation Manual This safety alert symbol identifies important safety messages

More information

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL 8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT

More information

Owner s/operator s Manual

Owner s/operator s Manual Water Pump MP2533E2 Owner s/operator s Manual Completely read and understand this manual before using this product. Foreword This Owner s/ Operator s Manual is designed to familiarize the operator with

More information

Medusa T1101 Generator

Medusa T1101 Generator Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Medusa Trade T2401 Generator

Medusa Trade T2401 Generator Please dispose of packaging for this product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Portable Electric/Gas Compressor Operating Instructions

Portable Electric/Gas Compressor Operating Instructions Portable Electric/Gas Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 TABLE OF CONTENTS Safety

More information

4000W GASOLINE DIGITAL INvERTER GENERATOR

4000W GASOLINE DIGITAL INvERTER GENERATOR 04/2017 4000W GASOLINE DIGITAL INvERTER GENERATOR Read this manual. Do not attempt to operate this generator until you have read and understood the safety, operation, and maintenance instructions MODEL:

More information

GENERATOR MODEL NO: FG4050ES / FG5100ES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS0310

GENERATOR MODEL NO: FG4050ES / FG5100ES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS0310 GENERATOR MODEL NO: FG4050ES / FG5100ES PART NO: 8857715, 8857720 OPERATION & MAINTENANCE INSTRUCTIONS LS0310 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this

More information

5625W GASOLINE GENERATOR WITH WHEEL KIT

5625W GASOLINE GENERATOR WITH WHEEL KIT 5625W GASOLINE GENERATOR WITH WHEEL KIT Read this manual. Do not attempt to operate this generator until you have read and understood the safety, operation, and maintenance instructions MODEL: KCG-5625G

More information

No part of this publication may be reproduced without written permission.

No part of this publication may be reproduced without written permission. Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EB3000 and EB4000 generators. All information in this publication is based on the latest product information

More information

HOFFMANN POWER PRODUCTS PARTS LIST 2014

HOFFMANN POWER PRODUCTS PARTS LIST 2014 HOFFMANN POWER PRODUCTS PARTS LIST 2014 VIBRATORY PLATE COMPACTOR ALL PARTS ARE SUBJECT TO STANDARD HOFFMANN TERMS AND CONDITIONS OF SALE 2010 Replacement parts are not manufactured, sold or warranted

More information

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual Petrol Engine Powered Pump Instruction Manual BIA-WP10-804448 CONTENTS 1. Safety information 2 2. Location of warning labels 3 3. Name of components 4 4. Pre-starting operation 5-7 5. Starting the engine

More information

GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT!

GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT! GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT! Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any

More information

Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G

Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G Thank you for choosing a generator set of our company. This manual contains the information on how to do that. Please read it carefully before operating.

More information

Medusa Compact T3001 Generator

Medusa Compact T3001 Generator Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

GENERATOR MODEL NO: DG6000DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1216

GENERATOR MODEL NO: DG6000DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1216 GENERATOR MODEL NO: DG6000DVES PART NO: 8675000 OPERATION & MAINTENANCE INSTRUCTIONS LS1216 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read

More information

Part No FJ180V KAI. 4-stroke air-cooled gasoline engine OWNER, S MANUAL

Part No FJ180V KAI. 4-stroke air-cooled gasoline engine OWNER, S MANUAL Part No. 99920-2280-02 FJ180V KAI 4-stroke air-cooled gasoline engine OWNER, S MANUAL SAFETY AWARENESS FOREWORD TABLE OF CONTENTS Whenever you see the symbols shown below, heed their instructions! Always

More information

GASOLINE GENERATOR SET USER S MANUAL

GASOLINE GENERATOR SET USER S MANUAL GASOLINE GENERATOR SET USER S MANUAL Foreword Thank you for purchasing our gasoline generator and hope that you will enjoy operating your unit, one of the finest models in the market. This Manual provides

More information

GENERATOR INVERTOR 1000W 230V

GENERATOR INVERTOR 1000W 230V INSTRUCTIONS FOR: GENERATOR INVERTOR 1000W 230V MODEL No: G1000I INSTRUCTIONS FOR: GENERATOR INVERTER 1000W 230V MODEL No: G1000I Thank you for purchasing a Sealey product. Manufactured to a high standard,

More information

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine HONDA GENERATORS ARE DESIGNED TO GIVE SAFE AND DEPENDABLE SERVICE IF OPERATED ACCORDING TO INSTRUCTIONS. YOU CAN HELP PREVENT ACCIDENTS BY BEING FAMILIAR WITH YOUR GENERATORS CONTROLS AND BY OBSERVING

More information

Generator Set. CP Range. Operating & Maintenance Instructions 0702

Generator Set. CP Range. Operating & Maintenance Instructions 0702 Generator Set CP Range Operating & Maintenance Instructions 0702 Read these safety instructions before using the equipment. Introduction Thank you for purchasing this Clarke portable Generator set. The

More information

User manual. B950I, B1000i, B2000i, B3000i

User manual. B950I, B1000i, B2000i, B3000i User manual B950I, B1000i, B2000i, B3000i Always read the user manual thoroughly before using the generator. Never use the generator in a closed room/area. Exhaust may cause suffocation. The exhaust pipe

More information

Water pump Owner's Manual

Water pump Owner's Manual Water pump Owner's Manual Safety Precautions I. General Safeguards Please read this operation manual to have a thorough understanding of the content there before use the product. Failure to do so may lead

More information

Generator OWNER S MANUAL. Read this manual carefully before operating this machine. PRO 2.8 i 7VU L1

Generator OWNER S MANUAL. Read this manual carefully before operating this machine. PRO 2.8 i 7VU L1 Generator OWNER S MANUAL Read this manual carefully before operating this machine. PRO.8 i 7VU-899-L - Read this manual carefully before operating this machine. This manual should stay with this machine

More information

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. PETROL GENERATOR OWNER S MANUAL PGH2200, PGH3000, PGH6500 FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. WARRANTY GENERATOR SAFETY This generator is covered by

More information

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. PETROL GENERATOR OWNER S MANUAL SPG2200, SPG3000, SPG6500 FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. WARRANTY This generator is covered by a 24 month warranty

More information

INVERTER GENERATOR P2000i

INVERTER GENERATOR P2000i INVERTER GENERATOR P2000i Operating Manual We Appreciate Your Business. Thank you and congratulations on choosing PRAMAC. This Operating Manual has been designed to instruct you on the correct use and

More information

CROMMELINS COMPACTORS

CROMMELINS COMPACTORS CROMMELINS COMPACTORS OPERATION & INSTRUCTION MANUAL Thank you for your selection of a CROMMELINS Compactor. This Operation Manual explains its use, installation, checking and maintenance. We highly recommend

More information

EC DECLARATION OF CONFORMITY

EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY 14 2500W INVERTER GENERATOR IM2500I CERTIFICATE OF GUARANTEE This product is guaranteed for a period of 1 Year, with effect from the date of purchase and applies only to the

More information

9500M. WARNING American Fab of SC, LLC Travelers Rest, SC OPERATOR S MANUAL INDUSTRIAL GASOLINE GENERATOR

9500M. WARNING American Fab of SC, LLC Travelers Rest, SC OPERATOR S MANUAL INDUSTRIAL GASOLINE GENERATOR 9500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL WARNING American Fab of SC, LLC Travelers Rest, SC It is extremely important to read and understand the entire contents of this operator s manual before

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual Petrol Engine Powered Pump Instruction Manual BIA-WP20ABS - 804450 BIA-WP30ABS - 804451 CONTENTS 1. Safety information 3 2. Location of warning labels 4 3. Components 5 4. Pre-starting operation 6 5.

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

Petrol Inverter Generator USER MANUAL

Petrol Inverter Generator USER MANUAL C M Y CM MY CY CMY K Petrol Inverter Generator USE MANUAL PLEASE EAD AND UNDESTAND THIS MANUAL COMPLETELY BEFOE OPEATING THE GENEATO. NOTE: The generator has been shipped without engine oil. Fill it with

More information

MTD OHV Series I15 FORM NO I. MTD Products Aktiengesellschaft Saarbrücken Germany

MTD OHV Series I15 FORM NO I. MTD Products Aktiengesellschaft Saarbrücken Germany MTD OHV Series I15 FORM NO. 769-01577I MTD Products Aktiengesellschaft Saarbrücken Germany 8 15 23 31 38 46 54 61 68 75 82 90 99 107 115 122 130 138 145 152 159 166 175 183 193 202 211 218 226 English

More information

Commercial Series Generator Operator Manual (with Kohler Command series engines)

Commercial Series Generator Operator Manual (with Kohler Command series engines) Commercial Series Generator Operator Manual (with Kohler Command series engines) PN: 220880 PREFACE Thank you for purchasing a Wanco Commercial Series portable generator set. This manual contains important

More information

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL 9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT

More information

Owner s Manual PORTABLE GENERATOR. Model: PR2800 PR6500

Owner s Manual PORTABLE GENERATOR. Model: PR2800 PR6500 PORTABLE GENERATOR Owner s Manual Model: PR2800 PR6500 ALLPOWER INDUSTRIES AUSTRALIA A.B.N 46 650 681 742 Unit 5, 102-128 Bridge Road, Keysborough, VIC 3173, Australia Telephone: +61 38726 1444 / 1800

More information

ENGINE DRIVEN 3 FULL TRASH PUMP

ENGINE DRIVEN 3 FULL TRASH PUMP ENGINE DRIVEN 3 FULL TRASH PUMP MODEL NO: PF75 PART NO: 7230165 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0117 ISS 2 INTRODUCTION Thank you for choosing this Clarke Pump. The function

More information

GEN 5.0 Generator Service Manual

GEN 5.0 Generator Service Manual GEN 5.0 Generator Service Manual IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers. Ensure

More information

WARNING! Ensure that there are no naked flames around the product! Do not smoke while filling fuel and oil!

WARNING! Ensure that there are no naked flames around the product! Do not smoke while filling fuel and oil! Engine Oil and Fuel Engine Operation This product is equipped with a 4 stroke engine. Before operation you have to add proper fuel and engine oil. DO NOT MIXTURE THEM! 1. Place the product on a stable,

More information

GEN3500 i 3,500 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

GEN3500 i 3,500 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL GEN3500 i 201403 3,500 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual Petrol Engine Powered Pump Instruction Manual BIA-HP15ABS - 804452 BIA-2HP15ABS - 804453 CONTENTS 1. Safety information 2 2. Location of warning labels 3 3. Components 4 4. Pre-starting operation 5 5.

More information

OPERATING AND MAINTENANCE INSTRUCTIONS. Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S)

OPERATING AND MAINTENANCE INSTRUCTIONS. Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S) GASOLINE POWERED PORTABLE GENERATORS OPERATING AND MAINTENANCE INSTRUCTIONS Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S) JOHN BROOKS COMPANY LIMITED TORONTO - MONTREAL

More information

EZT715-EZT750 Owner's Manual

EZT715-EZT750 Owner's Manual EN EZT715-EZT750 Owner's Manual ESS FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

800W Generator. Original manual AFTER SALES SUPPORT MODEL: WGG-800, 07/2012, 7597

800W Generator. Original manual AFTER SALES SUPPORT MODEL: WGG-800, 07/2012, 7597 ONTENTS or y handle lug key 800W Generator Original manual Now you have purchased a Workzone product you can rest assured in the knowledge that as well as your 3 year parts and labour guarantee you have

More information

1-1/2 DIAMETER WATER PUMP

1-1/2 DIAMETER WATER PUMP 1-1/2 DIAMETER WATER PUMP 2.2HP/79.8cc Engine MODEL # 101099 Operation Manual This safety alert symbol identifies important safety messages in this manual. Failure to follow this important safety information

More information

Instruction Model 18537

Instruction Model 18537 Instruction 738-556 Model 18537 LIMITED WARRANTY H. D. Hudson Manufacturing Company warrants to the original purchaser only that this product will continue to function as intended if used in accordance

More information

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 -

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 - Air Compressor ENGINE DRIVEN Operating & Maintenance Instructions 1110-1 - Read these safety instructions before using the equipment. INTRODUCTION Thank you for purchasing this Clarke portable compressor.

More information

PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual

PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure equipment is stopped and level before performing

More information

GARDEN HOSE UTILITY PUMP

GARDEN HOSE UTILITY PUMP GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before

More information

CROMTECH GENERATORS OPERATION & INSTRUCTION MANUAL. Thank you for your selection of a CROMTECH Generator.

CROMTECH GENERATORS OPERATION & INSTRUCTION MANUAL. Thank you for your selection of a CROMTECH Generator. CROMTECH GENERATORS OPERATION & INSTRUCTION MANUAL Thank you for your selection of a CROMTECH Generator. This Operation Manual explains its use, installation, checking and maintenance. We suggest that

More information

FX850V. 4 stroke air-cooled V-twin gasoline engine OWNER S MANUAL

FX850V. 4 stroke air-cooled V-twin gasoline engine OWNER S MANUAL FX850V 4 stroke air-cooled V-twin gasoline engine OWNER S MANUAL SAFETY AWARENESS Whenever you see the symbols shown below, heed their instructions! Always follow safe operating and maintenance practices.

More information

Earth Auger MAG500 MAG500RS

Earth Auger MAG500 MAG500RS Earth Auger MAG500 MAG500RS US Owner s/operator s Manual Completely read and understand this manual before using this product. - 0 - Foreword This Owner s/ Operator s Manual is designed to familiarize

More information

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS Petrol Driven Water Pump Model No. CD1-1 Part No. 7230034 OPERATING & MAINTENANCE INSTRUCTIONS Thank you for purchasing this Clarke CD1 petrol driven water pump. Before attempting to operate this pump

More information

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. GENERATOR SAFETY Only use outdoors! Never use during wet conditions! Do not smoke

More information

SGB12000HX PORTABLE GENERATOR

SGB12000HX PORTABLE GENERATOR 12KWG022004KOD PRINTED IN CANADA SGB12000HX PORTABLE GENERATOR OPERATING INSTRUCTIONS AND PARTS MANUAL John Brooks Company Limited Mississauga, Ontario L5N 7K5 12 1 Troubleshooting The majority of problems

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS WARNING Read the instructions before using the machine PETROL DRIVEN POWER WASHER MODEL NO: TIGER1700 PART NO: 7320054 OPERATION & MAINTENANCE INSTRUCTIONS LS0511 2 INTRODUCTION Thank you for purchasing

More information

IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation

IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation USER S MANUAL OUTDOOR USE ONLY! PLEASE READ AND UNDERSTAND

More information

AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR

AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR INDUSTRIAL GAS AIR COMPRESSOR OPERATOR S MANUAL IT IS ETREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING

More information

IMPORTANT: Read this manual fully before assembly and use and observe all safety rules and operating instructions

IMPORTANT: Read this manual fully before assembly and use and observe all safety rules and operating instructions PETROL ENGINE Model: MLR52 IMPORTANT: Read this manual fully before assembly and use and observe all safety rules and operating instructions Contents Technical Specification 2 Safety 3 Starting 5 Running

More information

MTD OHV Series FORM NO B. jqa=mêççìåíë=^âíáéåöéëéääëåü~ñí= =p~~êäêωåâéå= =déêã~åó

MTD OHV Series FORM NO B. jqa=mêççìåíë=^âíáéåöéëéääëåü~ñí= =p~~êäêωåâéå= =déêã~åó MTD OHV Series J15 FORM NO. 769-08890B jqa=mêççìåíë=^âíáéåöéëéääëåü~ñí= =p~~êäêωåâéå= =déêã~åó 4 11 19 27 35 43 51 58 65 72 79 87 96 104 112 119 126 134 141 148 155 162 171 179 188 197 206 213 221

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OPERATION MANUAL WARHORSE IMPORTANT SAFETY INSTRUCTIONS WARNING: Failure to observe these instructions can cause personal injury to machine operator or bystanders. WARNING: Asphyxiation Hazard. An improperly

More information

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

More information

Portable Oil Free Silent Series Compressor Operating Instructions

Portable Oil Free Silent Series Compressor Operating Instructions Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

General Power Products

General Power Products Portable Electric Generator Owners Manual MODEL: APP 6000 General Power Products IMPORTANT Please make certain the person who uses this Generator thoroughly reads these instructions and all other instructions

More information

3. INSPECTION/ADJUSTMENT

3. INSPECTION/ADJUSTMENT 3 3 INSPECTION/ADJUSTMENT SERVICE INFORMATION -------------------------------------------- 3-1 MAINTENANCE SCHEDULE ---------------------------------------- 3-2 FUEL LINE/FUEL FILTER -------------------------------------------

More information

WORKMATE TM Portable Generators

WORKMATE TM Portable Generators Owner s Guide for WORKMATE TM Portable Generators We are pleased to advise that your ADVANCED POWER WORKMATE Portable Generator Set is covered by warranty for a period of 36 months* from the date of its

More information

Model: SPTOGT01 TRACTOR PTO GENERATOR

Model: SPTOGT01 TRACTOR PTO GENERATOR www.scintex.com.au sales@scintex.com.au Model: SPTOGT01 TRACTOR PTO GENERATOR SET UP, OPERATING, AND SERVICING INSTRUCTIONS Read this material before using this product. Failure to do so can result in

More information

PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL

PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL 4/10/2012 PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT IS

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

Reproduction. Not for. Operator s Manual. Outdoor Inverter Generator. Model Number. Revision. Serial Number. Date Purchased

Reproduction. Not for. Operator s Manual. Outdoor Inverter Generator. Model Number. Revision. Serial Number. Date Purchased Outdoor Inverter Generator Operator s Manual Model Number Revision Serial Number Date Purchased Copyright 2016. Briggs & Stratton Power Products Group, LLC Milwaukee, WI, USA. All rights reserved. BRIGGS

More information

Owner s Manual. 100 Amp. DC WELDER 600W GENERATOR GASOLINE 6.5HP

Owner s Manual. 100 Amp. DC WELDER 600W GENERATOR GASOLINE 6.5HP Owner s Manual 100 Amp. DC WELDER 600W GENERATOR GASOLINE 6.5HP This manual provides information regarding the operation and maintenance of these products. We have made every effort to ensure the accuracy

More information

ULTRA QUIET & OIL FREE MP100LF MP120LF

ULTRA QUIET & OIL FREE MP100LF MP120LF ULTRA QUIET & OIL FREE AIR COMPRESSOR MOTOR/PUMP OwnER'S MAnUAL MP100LF MP120LF WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon 2 IMPortant SaFety

More information