Operating instructions Metering pumps Hydro/ 2 and Hydro/ 3

Size: px
Start display at page:

Download "Operating instructions Metering pumps Hydro/ 2 and Hydro/ 3"

Transcription

1 Operating instructions Metering pumps Hydro/ 2 and Hydro/ 3 EN P_HY_0004_SW Please carefully read these operating instructions before use. Do not discard. The operator shall be liable for any damage caused by installation or operating errors. The latest version of the operating instructions are available on our homepage Original Operating Instructions (2006/42/EC) BA HY /15 EN

2 Supplemental instructions Supplementary information Fig. 1: Please read! Read the following supplementary information in its entirety! Should you already know this information, you will benefit more from referring to the operating instructions. The following are highlighted separately in the document: Enumerated lists Operating guidelines ð Outcome of the operating guidelines - see (reference) Information This provides important information relating to the correct operation of the unit or is intended to make your work easier. Safety Information Safety information is identified by pictograms - see Safety Chapter. Information in supplier instructions Refer to the precise designation of suppliers' components in the "Technical Data" chapter for ease of finding the relevant information. Validity These operating instructions conform to current EU regulations applicable at the time of publication. State the identity code and serial number Please state identity code and serial number, which you can find on the nameplate when you contact us or order spare parts. This enables the unit type and material versions to be clearly identified. EX pumps only The nameplate stuck on the cover page is identical to the pump supplied so that there is a clear link between the operating instructions and the pump. 2

3 Table of contents Table of contents 1 Identity code Safety Chapter Storage, transport and unpacking Overview of device / control elements Functional description Assembly Installation Installation, hydraulic Basic installation notes Installation, Electrical Start up and operation Bleeding the liquid end Calibrate the stroke control drive (Option) Maintenance Repairs Cleaning valves Replacing the diaphragm Repair the diaphragm rupture sensor Calibrating the dosing rate Troubleshooting Decommissioning and Disposal Decommissioning Disposal Technical data Performance data Metering reproducibility Viscosity Weight Wetted materials Ambient conditions Temperatures Air humidity Installation height Housing degree of protection Motor data Diaphragm rupture sensor Safety relief valve (HP2 and HP3) Stroke sensor Heating cartridge Protection temperature limiter (ATEX only) Filling volumes Hydraulic oil Sound pressure level HP2a / Hp3a Supplement for modified versions Ordering Information Exploded view of the drawing Spare parts kits Diaphragms General Dimensional Drawings Earthing drawing

4 Table of contents 17 EC Declaration of Conformity for Machinery EC Declaration of Incorporation for ATEX HP2 Machines EC Declaration of Incorporation for ATEX HP3 Machines EC Declaration of Conformity for ATEX HP2 Machines EC Declaration of Conformity for ATEX HP3 Machines Diagrams for setting the metering capacity

5 Identity code 1 Identity code HP2a Hydro/ 2, version a Power end type H D E F A B Main power end Main power end, double head version Main power end for add-on power end Main power end double head version for add-on power end Add-on power end Add-on power end double head version Typ e * Capacity Performance data at maximum back pressure and type: refer to nameplate on the pump housing Dosing head material SS PV HC TT Stainless steel PVDF Hastelloy C PTFE + carbon Seal material T PTFE Displacement body 0 Standard multi-layer safety diaphragm with rupture signalling Dosing head design 0 no valve spring (standard) 1 With valve spring D Double ball valve (only for SST and HCT) H HV version for (only for ) Hydraulic connector 0 Standard threaded connector (in line with technical data) E F With DIN ISO flange With ANSI flange Design 0 with ProMinent logo (standard) 1 Without ProMinent logo M Modified* * order-related design, refer to order paperwork for pump features Electric power supply _ Connection data - see motor nameplate 1 No motor, with flange 200/80 3 No motor, with flange 160/71 4 No motor, with 56C flange (NEMA) 0 Add-on power end 5

6 Identity code HP2a Hydro/ 2, version a Degree of protection 0 IP 55 (Standard) ISO class F 1 Exe-design ATEX-T3 2 Exde-design ATEX-T4 A ATEX power end Stroke sensor 0 No stroke sensor (standard) 1 Stroke sensor (EX zone capable) Stroke length adjustment 0 Manual (standard) 1 With servomotor, 230 V, 50/60 Hz 2 With servomotor, 115 V, 60 Hz A With control motor ma 230 V, 50/60 Hz B With control motor ma 230 V, 50/60 Hz C With control motor ma 115 V, 60 Hz D With control motor ma 115 V, 60 Hz Hydraulic oil 0 Standard 1 Food approval for oil 2 Low temperature to Low temperature Zone 2 * Type, power (at 50 Hz) Type Capacity Type Capacity Type Capacity bar l/h bar l/h bar l/h Maximum back pressure for TTT material version: 16 bar! Maximum back pressure for PVT material version: 25 bar! 6

7 Identity code HP3a Hydro/ 3, version a Power end type H D E F A B Main power end Main power end, double head version Main power end for add-on power end Main power end double head version for add-on power end Add-on power end Add-on power end double head version Type Capacity Performance data at maximum back pressure and type: refer to the nameplate on the pump Dosing head material SS PV H C TT Stainless steel PVDF Hastelloy C PTFE + carbon Seal material T PTFE Displacement body 0 Standard multi-layer safety diaphragm with rupture signalling Dosing head design 0 no valve spring (standard) 1 With valve spring D Double ball valve (for , and SST / HTC) H HV version for (for , ) Hydraulic connector 0 Standard threaded connector (in line with technical data) E F With DIN ISO flange With ANSI flange Design 0 with ProMinent logo (standard) 1 Without ProMinent logo M Modified* * order-related design, refer to order paperwork for pump features Electric power supply _ Connection data - see motor nameplate 1 No motor, with flange 200/80 3 No motor, with flange 160/71 4 No motor, with 56C flange (NEMA) 0 Add-on power end Degree of protection 7

8 Identity code HP3a Hydro/ 3, version a 0 IP 55 (Standard) ISO class F 1 Exe-design ATEX-T3 2 Exde-design ATEX-T4 A ATEX power end Stroke sensor 0 No stroke sensor (standard) 1 Stroke sensor (EX zone capable) Stroke length adjustment 0 Manual (standard) 1 With servomotor, 230 V, 50/60 Hz 2 With servomotor, 115 V, 60 Hz A With control motor ma 230 V, 50/60 Hz B With control motor ma 230 V, 50/60 Hz C D With control motor ma 115 V, 60 Hz With control motor ma 115 V, 60 Hz Hydraulic oil 0 Standard 1 Food approval for oil 2 Low temperature to Low temperature Zone 2 * Type, power (at 50 Hz) Type Capacity Type Capacity Type Capacity bar l/h bar l/h bar l/h Maximum back pressure for TTT material version: 16 bar! Maximum back pressure for PVT material version: 25 bar! 8

9 Safety Chapter 2 Safety Chapter Explanation of the safety information The following signal words are used in these operating instructions to identify different severities of a hazard: Signal word WARNING CAUTION Meaning Denotes a possibly hazardous situation. If this is disregarded, you are in a life-threatening situation and this can result in serious injuries. Denotes a possibly hazardous situation. If this is disregarded, it could result in slight or minor injuries or material damage. Warning signs denoting different types of danger The following warning signs are used in these operating instructions to denote different types of danger: Warning signs Type of danger Warning hand injuries. Warning high-voltage. Warning flammable substances. Warning hot surface. Warning danger zone. Intended Use Only use the pump to meter liquid feed chemicals. In potentially explosive atmospheres only operate the pump with the appropriate nameplate for pumps for use in areas at risk of explosion in compliance with Directive 94/9/EC in accordance with the European guidelines. Ensure that the explosion group, category and degree of protection specified on the label corresponds to or is better than the conditions prevalent in the intended field of application. The pump is only approved for use with flammable feed chemicals if it has the identity code option "Multi-layer safety diaphragm with visual rupture display", is operated at back pressures over 2 bar with metal liquid ends and if the operator implements appropriate safety measures. Only use the pump after it has been correctly installed and started up in accordance with the technical data and specifications contained in the operating instructions. When working at temperatures arising using a heating cartridge, bear in mind their effect. Observe the general limitations with regard to viscosity limits, chemical resistance and density - see also the ProMinent Resistance List (in the Product Catalogue or at All other uses or modifications are prohibited. 9

10 Safety Chapter Never operate pumps in premises at risk from explosion without the relevant nameplate (and the respective EC Declaration of Conformity) for pumps for use in premises at risk from explosion. The pump is not intended for the metering of gaseous media and solids. The pump is not intended for the metering of explosive substances and explosive mixtures. The ATEX version is not intended for the metering of electrically nonconductive media (conductivity less than 50 ps/m). Do not expose the ATEX design to any ionising radiation, electromagnetic high frequency radiation in the range x10 15 Hz or ultrasound without putting in place measures in line with EN The pump is not intended for unprotected outside use. The pump is only intended for industrial use. The pump should only be operated by trained and authorised personnel, see the following table. You are obliged to observe the information contained in the operating instructions at the different phases of the unit's service life. You are obliged to observe the information contained in the operating instructions of the accessory devices at the different phases of their respective service lives. Qualification of personnel Task Storage, transport, unpacking Assembly Planning the hydraulic installation Hydraulic Installation Installation, electrical Start up Operation Maintenance, repair Decommissioning, disposal Troubleshooting Qualification Instructed person Technical personnel, service Qualified personnel who have a thorough knowledge of metering pumps In areas at risk from explosion: ATEX qualified person, ATEX electrical technician Technical personnel, service Electrical technician, In areas at risk from explosion: ATEX electrical technician Qualified personnel In areas at risk from explosion: Qualified personnel with ATEX training; checking of the electrical installation: recognised competent person Instructed person Technical personnel, service In areas at risk from explosion: ATEX qualified person, ATEX electrical technician Technical personnel, service Qualified person, electrical technician, instructed person, customer service - dependent on the requirement In areas at risk from explosion: ATEX electrical technician; checking of the electrical installation: recognised competent person 10

11 Safety Chapter Explanation of the table: Qualified personnel A qualified employee is deemed to be a person who is able to assess the tasks assigned to him and recognise possible dangers based on his/her technical training, knowledge and experience, as well as knowledge of pertinent regulations. Note: A qualification of equal validity to a technical qualification can also be gained by several years of employment in the relevant field of work. Electrical technician An electrical technician is able to complete work on electrical systems and recognise and avoid possible dangers independently based on his/her technical training and experience, as well as knowledge of pertinent standards and regulations. The electrical technician should be specifically trained for the working environment in which he is employed and know the relevant standards and regulations. An electrical technician must comply with the provisions of the applicable statutory directives on accident prevention. A qualification of equal validity to a technical qualification can also be gained by several years of employment in the relevant field of work. ATEX explosion protection electrical technician The electrical technician with an additional explosion protection qualification should be specifically trained for the work area in which they are employed and know the relevant standards and regulations. The electrical technician with an additional explosion protection qualification can work on electrical systems and independently recognise and avoid possible dangers based on their technical training and experience. The electrical technician with an additional explosion protection qualification is familiar with all the standards and regulations applicable to explosion protection, in particular, but not however exclusively, with all parts of EN [electrical equipment for areas at risk of a gas explosion]. The electrical technician with an additional explosion protection qualification must comply with the provisions of the applicable statutory directives on accident prevention. Recognised competent person To carry out explosion hazard inspections the competent person must have: completed a relevant course of study or a comparable technical qualification or another technical qualification combined with long-term experience of safety technology. The person must be knowledgeable in respect of the relevant body of standards and regulations and have worked in the area for at least one year. Participation in options for exchanging experience is required. Particular requirements are made in respect of competent persons who carry out tests on repaired devices/parts. They must be recognised in this respect by the responsible authorities (e.g. the district council). Instructed person An instructed person is deemed to be a person who has been instructed and, if required, trained in the tasks assigned to him/her and possible dangers that could result from improper behaviour, as well as having been instructed in the required protective equipment and protective measures. Service Customer Service department refers to service technicians, who have received proven training and have been authorised by ProMinent or Pro Maqua to work on the system. 11

12 Safety Chapter Safety information CAUTION! These operating instructions include notes and quotes from German guidelines relating to the system operator's scope of responsibility. This information does not discharge the operator from his responsibility as an operator and is intended only to remind him or make him aware of specific problem areas. This information does not lay claim to being complete, nor applicable to every country and every type of application, nor to being unconditionally up-to-date. Only use ATEX pumps in the area at risk from explosion Observe the European Operator Directive 99/92/EC (ATEX 137), implemented in Germany by the Industrial Health and Safety Regulation and the German Ordinance on Hazardous Substances, for the installation and operation of equipment in areas at risk from explosion. Observe the European standards EN , EN , EN , EN and EN and EN for inherently safe electrical circuits. (In Germany these standards are partly implemented by VDE 0165 and VDE 0118). Adhere to the respective national regulations outside of the EU. Ensure that installations in areas at risk from explosion are checked by a "recognised competent" person. This applies specifically to intrinsically safe circuits. The following information relates essentially to specifics in areas at risk from explosion and does not replace the standard operating instructions. Only clean plastic parts carefully with a damp cloth to avoid electrostatic charges and sparks. Warning of dangerous or unknown feed chemical Should a dangerous or unknown feed chemical be used: It may escape from the hydraulic components when working on the pump. Take appropriate protective measures before working on the pump (e.g. safety glasses, safety gloves,...). Observe the safety data sheet for the feed chemical. Drain and flush the liquid end before working on the pump. Danger from hazardous substances! Possible consequence: Fatal or very serious injuries. Please ensure when handling hazardous substances that you have read the latest safety data sheets provided by the manufacture of the hazardous substance. The actions required are described in the safety data sheet. Check the safety data sheet regularly and replace, if necessary, as the hazard potential of a substance can be re-evaluated at any time based on new findings. The system operator is responsible for ensuring that these safety data sheets are available and that they are kept up to date, as well as for producing an associated hazard assessment for the workstations affected. 12

13 Safety Chapter CAUTION! Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic components if they are manipulated or opened due to pressure in the liquid end and adjacent parts of the system. Disconnect the pump from the mains power supply and ensure that it cannot be switched on again by unauthorised persons. Depressurise the system before commencing any work on hydraulic parts. CAUTION! Warning of feed chemical spraying around An unsuitable feed chemical can damage the wetted parts of the pump. Take into account the resistance of the wetted materials when selecting the feed chemical - see the ProMinent Product Catalogue or visit our homepage. Danger of injury to personnel and material damage The pump must only be opened at those points required to be opened by these operating instructions. It may only be opened in other positions upon receipt of written authorisation from the ProMinent head office, Heidelberg. Adjusted pressure switches fail The switching point of the 42 V pressure switch must not be changed. The ATEX pressure switch must not be reprogrammed. It could result in overheating of the pump. CAUTION! Danger of personnel injury and material damage The use of untested third party parts can result in personnel injuries and material damage. Only fit parts to metering pumps, which have been tested and recommended by ProMinent. CAUTION! Danger from incorrectly operated or inadequately maintained pumps Danger can arise from a poorly accessible pump due to incorrect operation and poor maintenance. Ensure that the pump is accessible at all times. Adhere to the maintenance intervals. 13

14 Safety Chapter Information in the event of an emergency In the event of an electrical accident, disconnect the mains cable from the mains or press the emergency cut-off switch fitted on the side of the system! If feed chemical escapes, also depressurise the hydraulic system around the pump as necessary. Adhere to the safety data sheet for the feed chemical. Safety information for operating instructions Prior to commissioning of the system or system component, it is the responsibility of the system operator to obtain the latest safety data sheet for the chemicals / resources to be used with the system from the supplier. Based on the information provided in the data sheets concerning health and safety, water and environmental protection, and taking into consideration the actual operating environment on site, it is the responsibility of the operator to create the legal framework for safe operation of the system or system component, such as for example the preparation of operating instructions (operator duties). Safety Equipment Fixed, isolating protective equipment During use of the pump all such parts should be secured in their position. Protective equipment Terminal box cover, motor Flange cover, side only with ATEX version with addon power end: Coupling flange inspection cover only with ATEX version "without motor": Motor connection inspection cover Protective cowling above the motor fan Only with additional equipment: Their corresponding parts May only be removed by*: Electrical technician, ATEX electrical technician, customer service Service Service Service Service Technical personnel, service * Only if required by the operating instructions and if the mains cable remains disconnected from the mains voltage. Other safety equipment - ATEX Stick the following warning label to pumps that contain parts made of electrically non-conducting plastic. Never stick a second label on top of the label. Ensure that the label is always fitted and legible. Warnung Gefahr durch elektrostatische Entladungen - siehe Betriebsanleitung Fig. 2 Requirements, if the motor is being installed independently The operator must be able to: 14

15 Safety Chapter perform a risk assessment create and attach a nameplate create an EC Declaration of Conformity adapt the operating instructions, if necessary correctly install the motor for ATEX motors: perform an ignition hazard assessment Identity code versions of pumps in areas at risk from explosion Only combinations of identity code versions listed in the corresponding EC Declaration of Conformity in the appendix are permitted in areas at risk from explosion. PVDF is generally ruled out as material for the dosing head! Only use PTFE as the material for the dosing head together with an electrical diaphragm rupture sensor and a discharge-side flow control! Sound pressure level Sound pressure level LpA < 70 db according to EN ISO at maximum stroke length, maximum stroke rate, maximum back pressure (water) 15

16 Storage, transport and unpacking 3 Storage, transport and unpacking Safety information The transporting of pumps which have been used with radioactive feed chemicals is forbidden! They will also not be accepted by ProMinent! Only return the metering pump for repair in a cleaned state and with a flushed liquid end - refer to the chapter "Decommissioning"! Only return metering pumps with a completed Decontamination Declaration form. The Decontamination Declaration constitutes an integral part of an inspection / repair order. A unit can only be inspected or repaired when a Declaration of Decontamination Form is submitted that has been completed correctly and in full by an authorised and qualified person on behalf of the pump operator. The "Decontamination Declaration Form" can be found at CAUTION! Danger of environmental and material damage The unit can be damaged or oil may escape due to incorrect or improper storage or transportation! The unit should only be stored or transported in a well packaged state - preferably in its original packaging. Only transport the unit with the locking screw - not the bleed plug - fitted to the oil filling opening. The packaged unit should also only be stored or transported in accordance with the stipulated storage conditions. The packaged unit should be protected from moisture and the ingress of chemicals. CAUTION! Danger of environmental damage Pumps with a liquid end are supplied filled with oil. When transporting, take care that no oil can escape. Storage Personnel: Technical personnel 1. Plug the caps on the valves. 2. Check whether the sealing screw is in place on the oil filler neck. 3. Preferably place the pump standing vertically on a pallet and secure against falling over. 4. Cover the pump with a tarpaulin cover - allowing rear ventilation. Store the pump in a dry, sealed place under the ambient conditions according to chapter "Technical Data". 16

17 Storage, transport and unpacking Ambient conditions - refer to "Technical Data" chapter. 17

18 Overview of device / control elements 4 Overview of device / control elements A B C C B A B C Fig. 3: Hydro, single head and double head versions A Drive B Hydraulic end C Liquid end 1 Stroke adjustment knob 2 Safety relief valve 3 Oil level indicator P_HY_0005_SW 4 Gear bleeding plug 5 Oil drain plug 6 Oil drain screw 7 Stroke sensor (Option) 8 Diaphragm rupture sensor P_HY_0006_SW Fig. 4: Liquid end 1 Discharge valve 2 Diaphragm mounting plate 3 Diaphragm rupture sensor 4 Suction valve 5 Liquid end 18

19 Functional description 5 Functional description Pump The metering pump is an oscillating diaphragm pump, the stroke length of which can be adjusted. An electric motor drives the pump. Hydraulic end The hydraulic end has a fixed safety relief valve (5). The safety relief valve provides protection for the pump power end and the diaphragm if the liquid feed pressure becomes too high. If the discharge side of the liquid end is blocked, the safety relief valve (5) opens at a real opening pressure and allows the hydraulic oil to flow into the power end housing. The real opening pressure lies above the nominal pressure (the pressure stage) see chap. Technical Data. This does not guarantee protection of the system against overpressure! 19

20 Assembly 6 Assembly Compare the dimensions on the dimension sheet with those of the pump. Motor installation - for versions without a motor 1. Select a suitable motor - it must correspond to the data of one of the motors from the table "Motor data" - see Chapter "Technical data" In an area at risk from explosion, EX applies to selected equipment and methods! 2. Fit the motor correctly on the flange (qualified personnel). Observe the clutch operating instructions! In an area at risk from explosion, EX applies to selected equipment and methods! With a dog clutch: The claw on the motor shaft must be fixed at the correct height, see Fig. Ä Motor installation - for versions without a motor on page As you have converted an "incomplete machine" into a complete machine, you must perform a conformity assessment, risk assessment, create an EC Declaration of Conformity, fit a company nameplate,....for ATEX pumps: additionally perform an ignition hazard assessment 4. Complete the pump documentation / operating instructions. 20

21 Assembly Q P_HY_0060_SW Fig. 5: Correct heigh of the clutch claw on the motor shaft Hydro HP2 Size Motor flange Q 56C 2.06" B5, Dimensions in mm - unless otherwise indicated. Hydro HP3 Size Motor flange Q 56C 2.06" * B 14, Ø Dimensions in mm - unless otherwise indicated. * The inner diameter of the shaft is 19 mm! 21

22 Assembly Base h Danger of electric shock If water or other electrically conducting liquids penetrate into the drive housing, in any other manner than via the pump's suction connection, an electric shock may occur. Position the pump so that it cannot be flooded. P_MOZ_0016_SW Fig. 6 The pump can break through the base or slide off it Ensure that the base is horizontal, smooth and permanently load-bearing. Capacity too low Vibrations can disrupt the liquid end valves. The supporting floor must not vibrate. Space requirement A A P_MOZ_0018_SW Motor may overheat If the necessary cooling air supply is not guaranteed, the motor may overheat. In an area at risk from explosion, it could trigger an explosion. Maintain sufficient clearance between the air intake opening and the walls. The distance should be greater than 1/4 of the diameter of the air intake opening. The fan must not suck in the exhaust air from other devices. Fig. 7 CAUTION! Danger from incorrectly operated or inadequately maintained pumps Danger can arise from a poorly accessible pump due to incorrect operation and poor maintenance. Ensure that the pump is accessible at all times. Adhere to the maintenance intervals. Risk of burns with hot feed chemicals If hot feed chemicals can heat the liquid ends above the permissible surface temperatures, persons can suffer burns from them. Consider attaching a "Hot surface" label to the liquid end or... fitting a guard plate. Position the pump so that control elements, such as the stroke length adjustment knob, the indicating dial A or the oil inspection window, are accessible. 22

23 Assembly In so doing, ensure there is enough space to carry out an oil change (vent screws, oil drainage plugs, oil trough...). f Discharge valve 2 Dosing head 3 Suction valve f P_MOZ_0017_SW f 3 Ensure there is sufficient free space (f) around the dosing head as well as the suction and discharge valve so that maintenance and repair work can be carried out on these components. Fig. 8 Liquid end alignment Capacity too low The liquid end valves cannot close correctly if they are not upright. Ensure that the discharge valve is upright. Fastening Capacity too low Vibrations can disrupt the liquid end valves. Secure the metering pump so that no vibrations can occur. m DN m P_MOZ_0015_SW Fig Take the dimensions (m) for the fastening holes from the appropriate dimensions- or data sheets. 2. Fix the pump base to the supporting floor with sufficient strong screws. With externally mounted pumps fix the frame to the supporting floor with sufficient strong screws. 23

24 Installation 7 Installation CAUTION! Danger of injury to personnel and material damage Disregarding the technical data when installing may lead to personal injuries or damage to property. Observe the technical data- refer to chapter "Technical Data" and, where applicable, the operating instructions of the accessories. 7.1 Installation, hydraulic ATEX pumps in areas at risk from explosion Metering pumps in areas at risk from explosion are provided, as a matter of course, with an appropriate safety relief valve on the outlet side of the metering pump (which is used to protect against excessive heating due to overloading and impact sparks caused by the breakage of power end parts triggered by overloading). Likewise a temperature monitor or a pressure side flow control is to be fitting to metering pumps with hydraulic diaphragm control for T4. (Protection against impermissible heating up in the event of continuous operation by the internal relief valve). In the event of differing temperature classes amongst the diverse components, operation of the complete pumps should be based on the component with the lowest temperature class. Hydraulic diaphragm pumps are highly suitable, although the design with Ex "i" diaphragm rupture sensor and a pressure-side flow control is required. Ensure that installations in areas at risk from explosion are checked by a "recognised competent" person. Please note the relevant national regulations during installation! Danger of fire with flammable feed chemicals Combustible media may only be transported using stainless steel or Hastelloy C dosing heads. Metering pumps can be used for metering combustible media, however as a matter of principle only of a design including ATEX diaphragm rupture sensors and a pressure-side flow control. During filling and draining of the liquid end, an expert must ensure that feed chemical does not come into contact with oxygen. If necessary, the operator must implement further measures. 24

25 Installation Warning of feed chemical reactions to water Feed chemicals that should not come into contact with water may react to residual water in the liquid end that may originate from works testing. Blow the liquid end dry with compressed air through the suction connector. Then flush the liquid end with a suitable medium through the suction connector. The following measures are an advantage when working with highly aggressive or hazardous feed chemicals: Install a bleed valve with recirculation in the storage tank. Install an additional shut-off valve on the discharge or suction ends. CAUTION! Warning of backflow A back pressure valve or a spring-loaded injection valve do not represent absolutely leak-tight closing elements. For this purpose use a shut-off valve, a solenoid valve or a vacuum breaker. CAUTION! Suction problems possible The valves may no longer close properly with feed chemicals with a particle size of greater than 0.3 mm. Install a suitable filter in the suction line. CAUTION! Warning of the discharge line rupturing With a closed discharge line (e.g. from a clogged discharge line or by closing a valve), the pressure that the metering pump generates can reach several times more than the permissible pressure of the system or the metering pump. This could lead to lines bursting resulting in dangerous consequences with aggressive or hazardous feed chemicals. Install a relief valve that limits the pressure of the pump to the maximum permissible operating pressure of the system. CAUTION! Warning of the discharge line rupturing Hose lines with insufficient pressure rating may burst. Only use hose lines with the required pressure rating. 25

26 Installation CAUTION! Uncontrolled flow of feed chemical Feed chemicals can leak through a stopped metering pump if there is back pressure. Use an injection valve or a vacuum breaker. CAUTION! Uncontrolled flow of feed chemical Feed chemical can leak through the metering pump in an uncontrolled manner in the event of excessive priming pressure on the suction side of the metering pump. Do not exceed the maximum permissible priming pressure for the metering pump. Set up the installation properly. CAUTION! Warning against lines coming loose Suction, discharge and relief lines installed incorrectly can come loose from the pump connection. Only use original hoses with the specified hose diameter and wall thickness. Only use clamp rings and hose nozzles that fit the respective hose diameter. Always connect the lines without mechanical tension. Only connect steel piping via a flexible piping section to a plastic valve body - see the following figure P_MOZ_0021_SW Fig. 10: Connect the steel piping to the plastic pump body as shown 1 Steel piping 2 Flexible pipe section 3 Plastic valve body P_SI_0021 Fig. 11: Moulded composite seals with corrugated insert CAUTION! Warning against leaks Leaks can occur on the pump connection depending on the insert used. The pump is supplied with PTFE moulded composite seals with a flare, which are used for the pump connections. They seal the connections between grooved pump valves and the grooved inserts from ProMinent - see Fig. 11. However, in the event that a smooth insert is used (e.g. third party part), an elastomer flat seal must be used - see Fig

27 Installation CAUTION! Warning of feed chemical spraying around PTFE seals, which have already been used / compressed, can no longer reliably seal a hydraulic connection. New, unused PTFE seals must always be used. P_SI_0022 Fig. 12: Elastomer flat seal for a smooth insert CAUTION! Danger due to incorrect use of the pressure relief valve The pressure relief valve can only protect the motor and the gear, and that only against impermissible positive pressure that is monitored by the metering pump itself. It cannot protect the system against positive pressure. Protect the motor and gear of the system against positive pressure using other mechanisms. Protect the system against illegal positive pressure using other mechanisms. Precise metering is only possible when the back pressure is maintained above 1 bar at all times. If metering at atmospheric pressure, a back pressure valve should be used to create a back pressure of approx. 1.5 bar. Diaphragm rupture sensor CAUTION! Warning of unnoticed diaphragm rupture Only above approximately 2 bar system back pressure is a signal generated upon a diaphragm rupture. Only rely on the diaphragm rupture sensor at back pressures greater than 2 bar Basic installation notes Safety notes CAUTION! Danger resulting from rupturing hydraulic components Hydraulic components can rupture if the maximum permissible operating pressure is exceeded. Never allow the metering pump to run against a closed shut-off device. With metering pumps without integral relief valve: Install a relief valve in the discharge line. CAUTION! Hazardous feed chemicals can escape With hazardous feed chemicals: Hazardous feed chemical can leak out when using conventional bleeding procedures with metering pumps. Install a bleed line with a return into the storage tank. 27

28 Installation Shorten the return line so that it does not dip into the feed chemical in the storage tank. A) B) 1 1 * PD 2 2 P_MOZ_0043_SW Fig. 13: (A) standard installation, (B) with pulsation damper 1 Main line 2 Storage tank Legend for hydraulic diagram Symbol Explanation Symbol Explanation Metering pump Foot valve with filter meshes Injection valve Multifunctional valve Level switch Manometer 28

29 Installation 7.2 Installation, Electrical ATEX pumps in areas at risk from explosion Only connect potential-free as well as non-isolating low voltage switch accessories, such as diaphragm rupture indicators, stroke rate instruments etc., to an intrinsically safe circuit in areas at risk from explosion. If several electrical components are connected together, the safety of the entire connected system has to be tested and confirmed in terms of its safety. This can either be in the form of a declaration of conformity from the supplier (ProMinent) for the entire unit or, with the supply of individual components, with the operator's explosion protection document. Only motor protection switches, mains switches and fuses permitted for use in areas at risk from explosion in line with the manufacturer's information may be used as electrical components in areas at risk from explosion. Electrically connect the entire electrical units listed on the earthing diagram cleanly and permanently to an electrically clean earthing point, - e.g. with an earthing bar on your system. Electrically connect the electrical units fitted with a potential equalisation cable to each other, cleanly and permanently to an electrically clean potential equalisation point - e.g. with a potential equalisation bar on your system. Note the enclosed documentation for the individual electrical components. Please note the relevant national regulations during installation! Danger of electric shock Unprofessional installation may lead to electric shocks. Crimp cable end sleeves onto all shortened cable cores. Only technically trained personnel are authorised to undertake the electrical installation of the device. Danger of electric shock In the event of an electrical accident, it must be possible to quickly disconnect the pump, and any electrical ancillaries which may possibly be present, from the mains. Install an emergency cut-off switch in the mains supply line to the pump and any electrical ancillaries which may be present or Integrate the pump and electrical ancillaries which may be present in the emergency cut-off management of the system and inform personnel of the isolating option. Danger of electric shock This pump is equipped with a protective earth conductor, to reduce the risk arising from an electric shock. Connect the PE conductor to "earth" with a clean and permanent electrical connection. 29

30 Installation Danger of electric shock A mains voltage may exist inside the motor or electrical ancillaries. If the housing of the motor or electrical ancillaries has been damaged, you must disconnect it from the mains immediately. The pump must only be returned to service after an authorised repair. What requires electrical installation? Motor External fan (identity code option) Frequency converter (identity code option) Stroke control drive (identity code option) Stroke actuator (identity code option) Diaphragm rupture sensor (standard) Stroke sensor (identity code option) Heating cartridge (identity code option) Protective temperature limiter (identity code option) Earthing wires (to be installed by the site operator, compulsory in the area at risk from explosion) Potential equalisation line (to be provided on site, prescribed in the area at risk from explosion) Motor P_SI_0012_SW Fig. 14: Direction of rotation of motor ATEX pumps in areas at risk from explosion Use a suitable motor protection switch to protect power end motors. Use motor protection approved for this application with Ex"e" motors. (Protection against warming caused by overloading). Provide a time-delay residual current device. Ensure that motors are only installed and checked by a "recognised competent" person in areas at risk from explosion. Cleanly earth the motor via the mains cable. Observe the enclosed operating instructions for the Ex motor, especially the maintenance plan. Only motors with a frequency converter: Danger of electric shock On conducting parts of the motor with an integrated frequency converter and on the lines themselves, there remains a risk of an electric shock for 3 minutes after switching off the mains voltage. After switching off allow the device to stand for 3 minutes before opening the terminal box. 30

31 Installation CAUTION! The motor can be damaged Provide appropriate motor protection devices (e.g. motor protection switch with thermal overcurrent trip) to protect the motor against overloading. Fuses do not provide motor protection. CAUTION! Only motors with a frequency converter: The motor can be damaged If a motor with an integrated frequency converter is restarted within 3 minutes of switching off of the mains voltage, the input current limiter could be damaged. After switching off, allow the device to stand for at least 3 minutes before restarting. If the motor is controlled via a control, take this into consideration at the control. CAUTION! Pump can be damaged The pump can be damaged if the motor drives the pump in the wrong direction. Note the correct direction of rotation indicated by the arrow on the fan cover when connecting the motor, as shown in Ä Motor on page 30. Use an electrical isolating device in the mains supply cable, such as a mains switch, to be able to switch off the pump independently from the entire installation (e.g. for repairs). 1. Install a motor protection switch, as the motors have no fuse. 2. Install an emergency cut-off switch or include the motor in the emergency cut-off management of the system. 3. Only connect the motor to the power supply using a suitable cable. Key motor data can be found on the nameplate and in the Chapter "Technical data". The terminal wiring diagram is located in the terminal box. Motor data sheets, special motors, special motor flanges, external fan, temperature monitoring Further information on motors can be found on our website Motor data sheets can also be requested for the motors. With motors other than those with identity code specifications "S", "M" or "N": Pay special attention to the operating instructions for the motors. Special motors or special motor flanges are possible on request. 31

32 Installation External fan CAUTION! Provide a separate power supply for the external fan with motors with external fans (identity code specification "R" or "Z"). Variable speed motors with frequency converter Connect the motor as per the wiring diagram for the controller, if it is controlled by an electronic control unit (such as direct current motors by a frequency converter). Stroke length actuators / control power ends Connect the motors in accordance with the enclosed wiring diagram or as per the wiring diagram fixed to the inside of the housing. CAUTION! Only operate stroke length actuators / control drives when the pump is running! Otherwise they will become damaged. Diaphragm rupture sensor (Option) Danger of electric shock In event of a defect, there is a risk of electric shock when conductive feed chemical are used. For safety reasons we recommend connecting to a protective low voltage, e.g. in accordance with EN (SELV ). Risk of fire after a diaphragm rupture The electric diaphragm rupture sensor must switch off the pump immediately after a diaphragm rupture. Connect the pump and the diaphragm rupture sensor to a control so that the pump is stopped immediately in the event of a diaphragm rupture. CAUTION! Danger resulting from unnoticed diaphragm rupture If the pump has been ordered with an electric diaphragm rupture sensor, it must also be electrically installed. Install the enclosed diaphragm rupture sensor electrically to a suitable monitoring device. CAUTION! Additional damage with a ruptured diaphragm The diaphragm cannot be allowed to rupture fully if damage can be caused by hydraulic oil mixing with the feed chemical. The diaphragm rupture sensor must switch off the pump immediately. Only restart the pump once the diaphragm has been replaced. 32

33 Installation a) Diaphragm rupture sensor with switch contact The cable can be connected as required. b) Namur sensor, inherently safe The monitor / power supply installed by the customer must be able to evaluate the current variations of the Namur sensor for indicating a diaphragm rupture! In the area at risk from explosion: For the Namur sensor NJ1,5-8GM-N, also note the details of the type examination certificate PTB 00 ATEX 2048 X. When using combustible media: Risk of fire after a diaphragm rupture The electric diaphragm rupture sensor must switch off the pump immediately after a diaphragm rupture. Connect the pump and the diaphragm rupture sensor to a control so that the pump is stopped immediately in the event of a diaphragm rupture. Stroke sensor (optional) Connect the stroke sensor to a suitable monitoring device according to the details in the chapter "Technical Data" - also observe their technical data! The monitor / power supply installed by the customer must be able to evaluate the current variations of the Namur sensor for indicating a diaphragm rupture! In the area at risk from explosion: For the Namur sensor NJ1,5-8GM-N, also note the details of the type examination certificate PTB 00 ATEX 2048 X. Heating cartridge Install the heating cartridge according to its documentation. It must only be connected to the supplied power supply or the protective temperature limiter (for ATEX)! Earthing wires (mandatory for ATEX) Connect the electrical components of the entire installation supplied cleanly and permanently to an electrically clean earthing point, e.g. with an earthing bar on site - see earthing diagrams in the appendix. 33

34 Installation Potential equalisation lines (mandatory with ATEX) The entire installation supplied is provided ex works with the necessary potential equalisation lines. Electrically connect an additional potential equalisation cable from the potential equalisation cables from this system cleanly and permanently to an electrically clean potential equalisation point, e.g. to a potential equalisation bar on site. Other units Install the other units in line with their documentation. 34

35 Start up and operation 8 Start up and operation Safety information ATEX pumps in areas at risk from explosion Make sure that a suitably competent person checks whether the appropriate installation information from the "Installation " chapter has been implemented correctly. A "recognised competent person" must check the electrical installation and in particular the intrinsically safe electric circuit. Set the opening pressure of the relief valve at a maximum of no more than 1.5 times the rated pressure of the pump. Fire hazard with flammable media Only with combustible media: These may start to burn when combined with oxygen. During filling and draining of the liquid end, an expert must ensure that feed chemical does not come into contact with oxygen. Hot surface In event the power end motor is loaded excessively, its surface may become very hot. Avoid contact. If necessary, mount a guard plate. Risk of burns with hot feed chemicals If hot feed chemicals can heat the liquid ends above the permissible surface temperatures, persons can suffer burns from them. Consider attaching a "Hot surface" label to the liquid end or... fitting a guard plate. Only motors with a frequency converter: Danger of electric shock On conducting parts of the motor with an integrated frequency converter and on the lines themselves, there remains a risk of an electric shock for 3 minutes after switching off the mains voltage. After switching off allow the device to stand for 3 minutes before opening the terminal box. 35

36 Start up and operation CAUTION! Only motors with a frequency converter: The motor can be damaged If a motor with an integrated frequency converter is restarted within 3 minutes of switching off of the mains voltage, the input current limiter could be damaged. After switching off, allow the device to stand for at least 3 minutes before restarting. CAUTION! Feed chemical could escape Check suction and discharge lines, and liquid end with valves for leak-tightness and tighten if necessary. Check whether the necessary flushing pipes or bleed lines are connected. CAUTION! Prior to commissioning, check that the power end motor and corresponding ancillary equipment is connected in compliance with the regulations. CAUTION! When using pumps with speed control, observe the instructions in the frequency converter operating instructions. Observe the technical data CAUTION! Danger of material damage Observe the details in the chapter "Technical Data" (pressure, viscosity, resistance,...). Test the diaphragm rupture sensor CAUTION! Feed chemical can escape unnoticed If the diaphragm rupture sensor does not stop the pump or no alarm is triggered, feed chemical can escape unnoticed. Trigger the diaphragm rupture indicator - see chapter "Repairs" and in so doing check the reaction of the analysis unit. CAUTION! Only restart the pump once the diaphragm has been replaced after a diaphragm rupture if damage can be caused by hydraulic oil mixing with the feed chemical. 36

37 Start up and operation Pressure relief valve CAUTION! The pressure relief valve must not be adjusted. Checking the direction of rotation When commissioning the unit, check whether the drive motor is rotating correctly - check this against the arrow on the motor housing or the diagram in the chapter entitled "Electrical Installation." Risk of injury from the fan impeller The fan impeller beneath motor's fan cowling can cause severe injuries while it is turning. The pump must only be connected to the mains voltage with the fan cowling closed. Installing a vent screw Replace the sealing screw at the oil filler neck with the supplied vent screw - see chapter "Overview of equipment and control elements". On a new product, slight oil marks on the pump do not indicate leaks. Wipe away and note down oil positions. Only contact the supplier if it reoccurs. Use a safety relief valve CAUTION! Danger due to incorrect use of the safety relief valve The safety relief valve can only protect the motor and the gear, only against illegal positive pressure that is monitored by the metering pump itself. It cannot protect the system against positive pressure. Protect the motor and gear of the system against positive pressure using other mechanisms. Protect the system against illegal positive pressure using other mechanisms. The real opening pressure lies above the nominal pressure (the pressure stage) see chap. Technical Data. Checking the oil level When the pump is idle, check whether the oil level in the pump is in the middle of the oil level indicator. This will rule out the pump losing oil and suffering damage. Avoid particles For chemicals with a particle size greater than 0.3 mm, the valves may no longer close properly. Install a suitable filter in the suction line. 37

38 Start up and operation adjust the relief valve Only in the area at risk from explosion: Set the opening pressure of the relief valve at a maximum of no more than 1.5 times the rated pump pressure. Only with a heating cartridge: check the action of the heating cartridge Check the heating action of the heating cartridge and effectiveness of the protective temperature limiter. No overheating must occur, especially in the area at risk from explosion! Only at low temperatures: allow the pump to warm up 1. Switch on the heating cartridge, set the stroke length of the pump to "0" and start the pump. 2. Allow the pump to warm up for 5 minutes. 3. Set the stroke length of the pump to the required value. Earthing wires Check whether the earthing lines in the pump's electrical units are correctly connected and connected to a clean earth wire - see earthing diagrams in the appendix. Potential equalisation lines (mandatory with ATEX) Check whether the potential equalisation lines are sitting correctly on the pump and connected to a clean potential equalisation point. 8.1 Bleeding the liquid end When bleeding the liquid end or suction against pressure: Relieve the suction and discharge line from pressure! With dangerous or unknown feed chemicals, take suitable protective measures according to the safety data sheet! 1. Loosen the discharge line. 2. Install a piece of translucent hose. 3. Run the pump slowly until the feed chemical appears in the piece of hose. 4. Remove the piece of hose. 5. Mount the discharge line. 38

39 Start up and operation Eliminating suction problems (only for single ball valves with PTFE ball seat) For suction problems occurring during start up: Exclude the possibility that there are foreign bodies in the valve. Place the valve on a stable surface. Using a hammer (1) and a brass bar (2), gently tap the PTFE ball seat above the valve ball - see figure below. Then with the valve in a damp condition allow it to prime. Fig. 15: Tapping the valve set disc 8.2 Calibrate the stroke control drive (Option) The stroke control drive is calibrated to the ordered dosing rate ex-factory. In event that you want the stroke control drive to be calibrated to another dosing rate, please contact ProMinent. 39

40 Maintenance 9 Maintenance Safety information ATEX pumps in areas at risk from explosion Generally check the proper functioning of the system, particularly of the power end and bearings, by regular monitoring (for leaks, noises, temperatures, smell... ). Do not allow the pump to run hot due to a lack of oil. With lubricated metering pumps, regularly check for the presence of lubricant, for example by checking the liquid level, visual leak control etc. If oil is leaking, examine the leakage point immediately and eliminate the cause. Check the correct operation of the relief valve downstream of the pump. In premises at risk from explosion, the relief valve should prevent the gear from becoming overloaded and becoming hot. Observe the enclosed operating instructions for the Ex motor. Only with pumps with a motor flange: replace worn gear ring etc. of the clutch. Only with add-on power end: replace worn gear ring/dz element of the clutch. Check the seals of the pressure switch for leak-tightness. When cleaning plastic components, ensure that no electrostatic charges are generated by excessive friction. - see warning label. Replace wear parts, such as bearings, when there is an identifiable incidence of unacceptable wear. (The nominal service life cannot be calculated with lubricated bearings.) Only use genuine spare parts as replacements. A diagnostic device for bearing damage is very useful for the premature detection of bearing damage. Carry out tests and repair in compliance with DIN EN IEC and ensure that they are only performed by "experienced personnel with the requisite knowledge". These measures are deemed to be minimum protection measures by ProMinent. It is the duty of the operator to take appropriate measures to eliminate any further hazards known to him. ATEX pump in area at risk from explosion Static electricity can cause ignition sparks. Always earth the discharge and suction lines first before working on the pump. Fire hazard with flammable media Only with combustible media: These may start to burn when combined with oxygen. During filling and draining of the liquid end, an expert must ensure that feed chemical does not come into contact with oxygen. 40

41 Maintenance It is mandatory that you read the safety information and specifications in the "Storage, Transport and Unpacking" chapter prior to shipping the pump. CAUTION! Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic components if they are manipulated or opened due to pressure in the liquid end and adjacent parts of the system. Disconnect the pump from the mains power supply and ensure that it cannot be switched on again by unauthorised persons. Depressurise the system before commencing any work on hydraulic parts. Warning of dangerous or unknown feed chemical Should a dangerous or unknown feed chemical be used: It may escape from the hydraulic components when working on the pump. Take appropriate protective measures before working on the pump (e.g. safety glasses, safety gloves,...). Observe the safety data sheet for the feed chemical. Drain and flush the liquid end before working on the pump. Danger of an electric shock When working on the motor or electrical auxiliary equipment, there is a danger of an electric shock. Before working on the motor, take note of the safety instructions in its operating instructions! Should external fans, servomotors or other auxiliary equipment be installed, these should also be disconnected and checked that they are voltage free. Under heavy loading (e.g. continuous operation) shorter maintenance intervals are recommended than those given. Third party spare parts for the pumps may lead to problems when pumping. Use only original spare parts. Use the correct spare parts kits. In the event of doubt, refer to the exploded views and ordering information in the appendix. Inspection, daily Check the pump installation for. 41

42 Maintenance leaks Abnormal noises or squeaks Abnormal temperatures Abnormal odours Abnormal vibrations Other peculiarities In areas at risk from explosion: stop the pump immediately and rectify these peculiarities. ProMinent Services may be needed if required. 42

43 Maintenance Maintenance work: Interval Maintenance work Personnel Quarterly* ATEX pump only: Special maintenance work - refer to the "Safety information for ATEX pumps". Only pumps with add-on power end or "without motor" and/or with motor flange: Check the gear ring/dz element of the ROTEX coupling as per their manual. Open the inspection window on the flange to check. Re-close it! If the coupling is OK, the maintenance interval can be increased to 4000 hours. If the coupling is not clearly OK: Call the ProMinent Service. ATEX pump only: Check the seals of the EDS 4448 pressure switch at regular intervals (depending on the climatic conditions and the feed chemical) in respect of their serviceability and replace if necessary. Check the correct seating and state of the metering lines at both discharge and suction ends. Technical personnel Technical personnel Technical personnel After approx. 4,000 operating hours After approx. 5,000 operating hours Check that the suction valve and discharge valve are fitted tightly. Check whether the diaphragm rupture sensor stops the pump or generates an alarm after it is triggered, see the chapter "Repairs". Check for firm seating of the diaphragm rupture sensor. Check whether the overpressure signalling triggers when an overpressure exists. Check the secure seating of the overpressure signaller. Check the secure seating of the pressure limitation valve (50 Nm). With the pump running, check whether bubbles rise in the window of the bleed valve. Check that the flow is correct: Allow the pump to prime briefly. Check the tightness of the entire liquid end - particularly around the leakage hole! Check that the dosing head screws are tight. Check that the electrical connections are intact. Check the firm, clean electrical connection of the earthing wires. Check the firm, clean electrical connection of the potential equalisation wires. Check the oil level. Check the gear ring/dz element of the coupling as per their operating instructions. Change hydraulic oil - refer to "Changing hydraulic oil" in this chapter. Check whether the seals of the overpressure signalling system are OK and in case of doubt, replace. ATEX design only: Check the effectiveness of the protective temperature limiter for the heating cartridge. Technical personnel Technical personnel Technical personnel Technical personnel Technical personnel Technical personnel Technical personnel Technical personnel Technical personnel Technical personnel Electrician Electrical technician with additional explosion protection qualification Electrician Electrical technician with additional explosion protection qualification Electrician Electrical technician with additional explosion protection qualification Technical personnel Technical personnel Instructed personnel Technical personnel Technical personnel 43

44 Maintenance Interval Maintenance work Personnel After approx. 10,000 operating hours ** After approx. 20,000 operating hours ATEX design only: Arrange for immediate rectification of any outwardly apparent damage or corrosion on parts of the housing and on connecting parts of the heating cartridge or protective temperature limiter by the manufacturer using original spare parts. Diaphragm change - refer to "Diaphragm change" in the chapter "Repair". Follow the motor manufacturer's recommendations - see operating instructions for the motor. Customer Service department Technical personnel * Under normal loading (approx. 30% of continuous operation). Under heavy loading (e.g. continuous operation): Shorter intervals. ** under normal loading. With very unfavourable metering parameters: Shorter intervals. Hydraulic oil change Risk of burns due to hot hydraulic oil The hydraulic oil may become very hot when the pump is exposed to extensive loading. When draining oil, avoid contact with the oil running out. If the pump must be operated using hydraulic oil compatible with foodstuffs, then only foodsafe hydraulic oil must be used. Drain the hydraulic oil For the double-head versions, perform the following work simultaneously on both dosing heads. 1. Set the stroke adjustment dial (2) to "0". 2. Unscrew the gearbox vent stopper (3). 3. Place an oil trough under the oil drainage plug (5). 4. Unscrew the oil drainage plug (5) from the power end housing. 5. Allow the hydraulic oil to run out of the drive. 6. Place an oil trough under the hydraulic end. 7. Unscrew the oil drainage stopper (4) out of the hydraulic end. 8. Allow the hydraulic oil to run out of the hydraulic end. 9. Screw on the oil drain plug (5). 10. Screw in the oil drainage stopper (4) with a new seal. 44

45 Maintenance Fig. 16 Fill with hydraulic oil For the double-head versions, perform the following work simultaneously on both dosing heads. 1. Set the stroke adjustment knob (2) to "100%" and open the safety relief valve (1) - tighten the knurled screw. 2. Slowly fill hydraulic oil through the opening for the gearbox vent stopper (3) until the oil inspection window (6) is covered. Type HP2 1/3 HP3 1/3 3. Start the pump. Level of covering 4. Allow the pump to run for a further minutes. 5. Top up with hydraulic oil if necessary. 6. Screw the gearbox vent stopper (3) back in. Do not close the bleed valve! 7. Close the safety relief valve (1) - loosen the knurled screw. 8. Check whether these whole openings are tightly sealed again, especially in the area at risk from explosion. Only in areas at risk from explosion: Check after 1 day whether the oil drainage stopper (4) and the oil drainage plug (5) are still tight. 45

46 Repairs 10 Repairs Safety information ATEX pumps in the ATEX area Generally check the proper functioning of the system, particularly of the power end and bearings, by regular monitoring (for leaks, noises, temperatures, smell... ). ATEX pump in area at risk from explosion Static electricity can cause ignition sparks. Always earth the discharge and suction lines first before working on the pump. Fire hazard with flammable media Only with combustible media: These may start to burn when combined with oxygen. During filling and draining of the liquid end, an expert must ensure that feed chemical does not come into contact with oxygen. It is mandatory that you read the safety information and specifications in the "Storage, Transport and Unpacking" chapter prior to shipping the pump. CAUTION! Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic components if they are manipulated or opened due to pressure in the liquid end and adjacent parts of the system. Disconnect the pump from the mains power supply and ensure that it cannot be switched on again by unauthorised persons. Depressurise the system before commencing any work on hydraulic parts. Warning of dangerous or unknown feed chemical Should a dangerous or unknown feed chemical be used: It may escape from the hydraulic components when working on the pump. Take appropriate protective measures before working on the pump (e.g. safety glasses, safety gloves,...). Observe the safety data sheet for the feed chemical. Drain and flush the liquid end before working on the pump. 46

47 Repairs Risk of fingers being crushed Under unfavourable conditions, the stroke axle or displacement body can cause crushing of the fingers. Disconnect the pump from the mains power supply and ensure that it cannot be switched on again by unauthorised persons. Risk of injury from the fan impeller The fan impeller beneath motor's fan cowling can cause severe injuries while it is turning. The pump must only be connected to the mains voltage with the fan cowling closed. Hot oil and hot components The hydraulic oil and the hydraulic end may become very hot when the pump is exposed to heavy loading. Allow the pump to cool before starting work. Unsuitable spare parts for the valves may lead to problems for the pumps. Only use new components that are especially adapted to fit your valve (both in terms of shape and chemical resistance). Use the correct spare parts kits. If in doubt, refer to the exploded drawings and ordering information on our website or - if included - the "Supplementary CD for Operating Instructions". Unsuitable spare parts for the valves may lead to problems for the pumps. Only use new components that are especially adapted to fit your valve (both in terms of shape and chemical resistance). Use the correct spare parts kits. In the event of doubt, refer to the exploded views and ordering information in the appendix Cleaning valves Clean the discharge and suction valves only one after another as they cannot be differentiated using the arrow markings. For orientation: Should you have a dismantled liquid end in front of you, the suction valve is on the side of the diaphragm rupture sensor. 47

48 Repairs Personnel: Technical personnel Cleaning a discharge valve (double ball) Taking the discharge valve apart 1. Loosen the discharge line. 2. Unscrew the discharge valve from the dosing head and rinse out. 3. Remove the remaining parts from the dosing head. 4. Allow the parts from the valve body (1) to fall as far as possible. 5. Using an Allen key or similar, insert it through the hole of the valve body (1) and push the remaining parts out of it. 6. Remove the last seal (2) and the last ball seat (3) from the valve body (1) using a small screwdriver. 7. Rinse and clean all parts. 8. Replace the worn parts and seals. Assembling the discharge valve When assembling, take note of the orientation of the valve seats (3). The valve seats (3) are used as a ball seat on the fine machined side and as a ball cage and spring guide on the other side. The fine machined side must point in the flow direction with all valve seats. When assembling the valves, take note of the sequence: Teflon Metal Teflon Metal * 5 1. Slide into the valve body (1) one after another: one seal (2) and one valve seat (3) - correct! one seal (2) and one valve bushing (4) (If fitted: allow one spring (*) to slide into the spring guide of the valve seat (3) slide one ball (5) into the valve body (1) one seal (2) and the second valve seat (3, correct!) one seal (2) and the second valve bushing (4) (If fitted: allow the second spring (*) to slide into the spring guide of the valve seat (3) slide the second ball (5) into the valve body (1) one seal (2), the third valve seat (3) - (correct!) and a further seal (2) 2. Position the insert disc (6) with the flare on the packing. * The distance between the edge of the valve body and the insert disk (6) is due to the construction Place the larger seal (7) between the insert disk (6) and the dosing head. 4. Screw in the valve until the stop. 5. Fix the discharge line. Fig. 17 Cleaning a suction valve (double ball) A suction valve is dismantled, cleaned and assembled in the same way as a discharge valve. 48

49 Repairs Please note, however, that when assembling, the valve seat (3) must be aligned in the other direction. The fine machined side must point in the flow direction with all valve seats (3) Replacing the diaphragm Important note Observe the safety information at the beginning of the chapter. CAUTION! A diaphragm rupture may remain unnoticed Should the multi-layer diaphragm be treated incorrectly, diaphragm rupture signalling may fail. Take the multi-layer diaphragm from the packaging immediately before installing. No impurities must contact the multi-layer diaphragm. Do not "inspect" the insert disc. For the double-head versions and add-on power ends, perform the following work simultaneously on both dosing heads. Drain the hydraulic oil from the hydraulic end Position numbers - see chapter "Maintenance" 1. Turn the stroke adjustment dial (2) more than 100% to the stop. 2. Unscrew the gearbox vent stopper (3). 3. Place an oil trough under the hydraulic end. 4. Unscrew the oil drainage stopper (4) out of the hydraulic end. 5. Allow the hydraulic oil to run out of the hydraulic end. 6. Screw in the oil drainage stopper (4) with a new seal. Changing the diaphragm for HP2 and HP Fig

50 Repairs 1. Depressurise the suction and discharge lines. 2. Unscrew the suction and discharge lines from the liquid end. Is the hydraulic oil drained - see above? 3. Remove the liquid end with the dosing head screws from the hydraulic end. 4. Release the diaphragm mounting plate (2) with diaphragm (1) from the dosing head. 5. Warning of injury to eyes The spring (3) and the spring plate (5) on the diaphragm core (6) may spring away when loosening the safety collar (4). Wear safety glasses. Release the safety collar (4) and the spring (3) with the spring plate (5) from the diaphragm core 6. Release the safety collar (4). 7. Pull the spring (3) with the spring collar (5) from the diaphragm anchor. 8. Remove the diaphragm / diaphragm anchor combination from the diaphragm mounting plate (2). 9. Place the new diaphragm / diaphragm anchor combination into the diaphragm mounting plate (2). 10. Push the diaphragm spring (3) with the spring collar (5) on to the diaphragm anchor (6). 11. Secure the spring collar (5) using the safety collar (4). 12. Replace the O-ring (7) between the diaphragm mounting plate (2) and the hydraulic end. 13. Place the diaphragm (1) with the diaphragm mounting plate (2) inside the hydraulic end. 14. Position the dosing head with the screws so that the suction connector is pointing downwards - diaphragm sensor must be at the bottom. 15. First gently tighten the dosing head screws and then tighten crosswise, tightening torque - Ä Tightening torque for screws on page Test the diaphragm rupture sensor - see Ä Changing the diaphragm for HP2 and HP3 on page Screw the suction and discharge line on to the liquid end. 1 2 Fig. 19: Wetted areas (grey shaded) 50

51 Repairs Tightening torque for screws Dosing head material PVT TTT HCT SST Tightening torque 12 Nm 12 Nm 20 Nm 20 Nm Fill hydraulic oil in the hydraulic end For the double-head versions, perform the following work simultaneously on both dosing heads. 1. Set the stroke adjustment dial (1) to "100%" and open the safety relief valve (2) - tighten the knurled screw. 2. Slowly fill hydraulic oil through the opening for the gearbox vent stopper (4) until the oil inspection window (3) is covered to 1/3. 3. Start up the pump. 4. Allow the pump to run for minutes. 5. Screw the gearbox vent stopper (3) back in. Do not close the bleed valve! 6. Close the safety relief valve (1) - loosen the knurled screw. 7. Check the pump for tightness by using maximum back pressure. Check the tightening torque of the dosing head screws again after 24-hours of operation! 10.3 Repair the diaphragm rupture sensor Warning of feed chemical After diaphragm rupture, additional feed chemical will be present in the diaphragm rupture sensor and the inlet channel in the dosing head! If using hazardous or unknown feed chemicals then protect yourself against the feed chemical. Observe the safety data sheet. 30 V version Check diaphragm rupture sensor 51

52 Repairs When changing the diaphragm, unscrew the diaphragm rupture sensor from the dosing head. 2. Check for electrical continuity: 3. Using a blunt insulating probe (Ø mm, no sharp edges), press into the channel of the diaphragm rupture sensor. ð Check that there is no electrical continuity 4. Release the pin again. ð Electrical continuity must be re-established. 5. Repeat the test several times. 6. If everything is working correctly, screw the diaphragm rupture sensor into the dosing head with a new seal (1). 7. If not, go to the next section. Replace separating diaphragm of the diaphragm rupture sensor Fig Disconnect the diaphragm rupture sensor from the power supply. 2. When changing the diaphragm, unscrew the diaphragm rupture sensor from the dosing head. 3. Grasp the upper section (2) of the diaphragm rupture sensor. 4. Hold the body (5) in place with an open-ended spanner. 5. Unscrew the top of the diaphragm rupture sensor. 6. Clean the soiled parts. 7. Lay the new separating diaphragm (3) with the light side (PTFE) down into the upper section (2). 8. Lay the plate (4) with the uneven side down into the upper section (2). 9. Screw the body (5) into the upper section and screw tighten. 10. Check the diaphragm rupture sensor as described in Check diaphragm rupture sensor". 11. If the diaphragm rupture sensor does not operate clearly and reliably, then a new diaphragm rupture sensor must be used without fail. ATEX version Checking the diaphragm rupture sensor 52

53 Repairs a When changing the diaphragm, unscrew the diaphragm rupture sensor from the dosing head. 2. Check that the monitor does not indicate a diaphragm rupture: 3. Using a blunt insulating probe (Ø mm, no sharp edges), press into the channel of the diaphragm rupture sensor. ð The monitor device should indicate a diaphragm rupture. 4. Release the pin again. ð The monitor device should no longer indicate a diaphragm rupture. 5. Repeat the test several times. 6. If everything is working correctly, screw the diaphragm rupture sensor into the dosing head with a new seal (1). 7. If not, go to the next section. Replace the separating diaphragm of the diaphragm rupture sensor P_HY_0015_SW Fig Disconnect the diaphragm rupture sensor from the monitor. 2. When changing the diaphragm, unscrew the diaphragm rupture sensor from the dosing head. 3. Grasp the top part (2) of the diaphragm rupture sensor. Do not tamper with the lacquer-protected nut. 4. Hold the body (5) in place with an open-ended spanner. 5. Unscrew the top of the diaphragm rupture sensor. 6. Clean any dirty parts. 7. Lay the new separating diaphragm (3) with the light side (PTFE) down into the top part (2). 8. Place the disc (4) in the top part (2). 9. Place the spring into the body (5). 10. Move the body (5) close to the top part (2). ð The spring (6) should sit correctly on the spring seat (3a). 11. Screw the body (5) into the top part and tighten. 12. Connect the diaphragm rupture sensor back to the monitor. 13. Check the diaphragm rupture sensor as described under Checking diaphragm rupture sensor". 14. If the diaphragm rupture sensor does not operate clearly and reliably, then definitively use a new diaphragm rupture sensor Calibrating the dosing rate It is only worth calibrating the dosing rate if you wish to carry out particularly precise metering at a completely different back pressure. The dosing rate of the hydraulic diaphragm metering pump is only dependent upon back pressure to a minimal extent. And the pumps are calibrated on the factory premises to the maximum operating pressure. (Values of the maximum operating pressures - see the pressure stage on the indicating dial or safety relief valve). 53

54 Repairs The plant or production facility can calibrate each pump to a back pressure that is lower than the nominal pressure ordered. The following pressure stages (in bar) are available: Pump HP2, HP3 X X X X X X ATEX pump only: Take suitable precautions in potentially explosive atmospheres regarding the feed chemical in the open measuring cylinder - see handling instructions below. The dosing rate can only be calibrated when the discharge line is connected and under normal operating conditions. As the dosing rate is dependent upon the actual back pressure. a) 4 b) t 1 t 2 Q 1 Q 2 Fig. 22: a) Adjust indicating dial, b) Schematic assembly for calibration Materials required: Measuring beaker Stop watch 1. Switch off the pump. 2. Turn the stroke adjustment dial to maximum, beyond 100% to the stop. 3. API versions only: Remove the metal cap from the stroke adjustment dial. 4. Remove the cover (4) from the stroke adjustment dial and slacken off the screw (3) beneath slightly. 5. Guide the suction line into a measuring beaker - see Fig Fill the measuring beaker with feed chemical. 7. Start the pump. 8. As soon as the system back pressure of the system has been reached, determine the fill level Q 1 and start the stopwatch. 9. Run the pump for a while. 10. Simultaneously determine the fill level Q 2 and stop the stopwatch. 11. Calculate the dosing rate value. 12. Reduce the dosing rate using the stroke adjustment dial and repeat steps 7 to 10 until the required value is reached. 54

55 Repairs 13. Turn the indicating dial (1) only until the 100% marking is precisely above the indicating slot (2). 14. Carefully tighten the screw (3) in the stroke adjustment dial and replace the cap (4). 15. API versions only: Press the metal cap on to the stroke adjustment dial. 55

56 Troubleshooting 11 Troubleshooting Safety information ATEX pumps in the ATEX area Generally ensure proper functioning (no leaks, unusual noises, high temperatures, unusual smell...) especially of the power end/drive and the bearings. Do not allow the pump to heat up because of lack of oil. With lubricated metering pumps, regularly check for the presence of lubricant, for example by checking the liquid level, visual leak control etc. If oil is leaking, examine the leakage point immediately and eliminate the cause. When cleaning plastic components, ensure that no electrostatic charges are generated by excessive friction. - see warning label. Replace wear parts, such as bearings, when there is an identifiable incidence of unacceptable wear. (The nominal service life cannot be calculated with lubricated bearings.) Only use genuine spare parts as replacements. Carry out tests and repair in compliance with DIN EN IEC and ensure that they are only performed by "experienced personnel with the requisite knowledge". Make sure that a "recognised competent person" checks the electrical installation and in particular the intrinsically safe electric circuits. ATEX pump in area at risk from explosion Static electricity can cause ignition sparks. Always earth the discharge and suction lines first before working on the pump. Fire hazard with flammable media Only with combustible media: These may start to burn when combined with oxygen. During filling and draining of the liquid end, an expert must ensure that feed chemical does not come into contact with oxygen. Danger of an electric shock Personnel working on electrical parts can be electrocuted if all electrical lines carrying current have not been disconnected. Disconnect the supply cable before working on the motor and prevent it from being reconnected accidentally. Any separately driven fans, servo motors, speed controllers or diaphragm rupture sensors fitted should also be disconnected. Check that the supply cables are de-energised. 56

57 Troubleshooting Warning of dangerous or unknown feed chemical Should a dangerous or unknown feed chemical be used: It may escape from the hydraulic components when working on the pump. Take appropriate protective measures before working on the pump (e.g. safety glasses, safety gloves,...). Observe the safety data sheet for the feed chemical. Drain and flush the liquid end before working on the pump. Risk of injury from the fan impeller The fan impeller beneath motor's fan cowling can cause severe injuries while it is turning. The pump must only be connected to the mains voltage with the fan cowling closed. Only motors with a frequency converter: Danger of electric shock On conducting parts of the motor with an integrated frequency converter and on the lines themselves, there remains a risk of an electric shock for 3 minutes after switching off the mains voltage. After switching off allow the device to stand for 3 minutes before opening the terminal box. CAUTION! Only motors with a frequency converter: The motor can be damaged If a motor with an integrated frequency converter is restarted within 3 minutes of switching off of the mains voltage, the input current limiter could be damaged. After switching off, allow the device to stand for at least 3 minutes before restarting. CAUTION! Danger of personnel injury and material damage The use of untested third party parts can result in personnel injuries and material damage. Only fit parts to metering pumps, which have been tested and recommended by ProMinent. 57

58 Troubleshooting CAUTION! Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic components if they are manipulated or opened due to pressure in the liquid end and adjacent parts of the system. Disconnect the pump from the mains power supply and ensure that it cannot be switched on again by unauthorised persons. Depressurise the system before commencing any work on hydraulic parts. Tasks Fault description Cause Remedy Personnel Pump fails to pressurise or does not prime in despite full stroke motion and bleeding The valves are dirty or worn. The feed chemical has particles larger than 0.3 mm. Repair the valves - see chapter entitled "Repair". Install a suitable filter in the suction line. Technical personnel Technical personnel Safety relief valve is open. Unscrew knurled screw in safety relief valve. Instructed personnel Safety relief valve is heavily worn as discharge line is greatly constricted. Replace safety relief valve and remove blockage from discharge line Technical personnel Insufficient hydraulic oil in the power end. Refill with hydraulic oil until oil inspection window is 1/3 covered - see "Diaphragm change" in the chapter "Repair". Instructed personnel Investigate and clear the cause of the oil loss. The oil inspection window is leaking. Replace the oil inspection window as per the operating instructions. Technical personnel Indicating dial is set incorrectly. Set indicating dial - see "Calibrate metering capacity"in the chapter "Repair". Technical personnel The motor is wired incorrectly. 1. Check the mains voltage and mains frequency. Electrician 2. Wire the motor correctly. The mains voltage has failed. Eliminate the cause. Electrician Operating diaphragm ruptured and alarm has not sounded. Replace multi-layer diaphragm immediately - see "Diaphragm change" in the chapter "Repair". Replace separating diaphragm of the diaphragm rupture sensor- see "Replacing the separating diaphragm, diaphragm rupture sensor" in the chapter "Repair". Technical personnel The overpressure sensor has triggered. There is a blockage in the discharge line. Clear the blockage. Technical personnel The system back pressure was momentarily too high. Clear the cause of the back pressure. Technical personnel 58

59 Troubleshooting Fault description Cause Remedy Personnel The diaphragm rupture sensor has triggered. The power end motor is very hot. The operating diaphragm has ruptured. The discharge line is seriously constricted. Replace multi-layer diaphragm immediately - see "Diaphragm change" in the chapter "Repair". Replace separating diaphragm of the diaphragm rupture sensor- see "Replacing the separating diaphragm, diaphragm rupture sensor" in the chapter "Repair". Rectify any constriction of the discharge line. Have the safety relief valve checked. All other faults. Other causes. Call the ProMinent Service. Technical personnel Technical personnel 59

60 Decommissioning and Disposal 12 Decommissioning and Disposal 12.1 Decommissioning Fire hazard with flammable media Only with combustible media: These may start to burn when combined with oxygen. During filling and draining of the liquid end, an expert must ensure that feed chemical does not come into contact with oxygen. Danger of an electric shock When working on the motor or electrical auxiliary equipment, there is a danger of an electric shock. Before working on the motor, take note of the safety instructions in its operating instructions! Should external fans, servomotors or other auxiliary equipment be installed, these should also be disconnected and checked that they are voltage free. Danger from chemical residues There is normally chemical residue in the liquid end and on the housing after operation. This chemical residue could be hazardous to people. It is mandatory that the safety note relating to the "Storage, Transport and Unpacking" chapter is read before shipping or transporting the unit. Thoroughly clean the liquid end and the housing of chemicals and dirt. Adhere to the safety data sheet for the feed chemical. Warning of dangerous or unknown feed chemical Should a dangerous or unknown feed chemical be used: It may escape from the hydraulic components when working on the pump. Take appropriate protective measures before working on the pump (e.g. safety glasses, safety gloves,...). Observe the safety data sheet for the feed chemical. Drain and flush the liquid end before working on the pump. Hot oil and hot components The hydraulic oil and the hydraulic end may become very hot when the pump is exposed to heavy loading. Allow the pump to cool before starting work. 60

61 Decommissioning and Disposal CAUTION! Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic components if they are manipulated or opened due to pressure in the liquid end and adjacent parts of the system. Disconnect the pump from the mains power supply and ensure that it cannot be switched on again by unauthorised persons. Depressurise the system before commencing any work on hydraulic parts. CAUTION! Danger of damage to the device The device can be damaged by incorrect and improper storage or transportation. Take into account the information in the "Storage, Transport and Unpacking" chapter if the system is decommissioned for a temporary period. Personnel: Technical personnel 1. Disconnect the pump from the mains power supply. 2. Depressurise and bleed the hydraulic system around the pump. 3. Flush the liquid end with a suitable medium - Observe the safety data sheet! Flush the dosing head thoroughly when using hazardous feed chemicals! 4. Drain the hydraulic oil - see chapter "Maintenance". 5. Thoroughly clean the liquid end and the housing of chemicals and dirt. 6. Possible additional work - see chapter "Storage, Transport and Unpacking" Disposal Personnel: Technical personnel Danger due to spring tension There is a spring under high tension between the diaphragm and the diaphragm mounting plate. Wear safety glasses. Danger due to spring tension There is a spring under high tension below the hydraulic cap under the diaphragm mounting plate. Only remove the hydraulic cap in line with the "Hydro repair and configuration instructions." 61

62 Decommissioning and Disposal CAUTION! Environmental hazard due to hydraulic oil The pump contains hydraulic oil, which can cause damage to the environment. Drain the hydraulic oil from the pump. Note the local guidelines currently applicable in your country! 62

63 Technical data 13 Technical data Only for "M - modified" design: Risk of personal injuries Please observe the Supplement for modified version at the end of the chapter! It replaces and supplements the technical data! 13.1 Performance data HP2a at 50 Hz operation Type Minimum pump capacity at maximum back pressure Maximum stroke rate Suction lift Permissible priming pressure, suction side bar l/h ml/stroke Strokes/min m WS bar G-DN Connector size * Rp 3/8" * Rp 3/8" * Rp 3/8" * Rp 3/8" * Rp 3/8" G 3/4" G 3/4" G 3/4" G 3/4" G 3/4" G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** * Material version SST / HCT with double ball valve Alternative double ball valve SST with RP 3/8 ** HV design G1-DN 15 Maximum back pressure for liquid ends in material version PVT: 25 bar! The metering capacity can deviate from the details above with the HV version. All figures refer to water at 20 C. Priming lift / priming pressure (dry) determined for empty suction line and empty liquid end and as well as clean and moistened valves (the figures are lower with valve springs). The suction lift / suction pressure applies to filled suction lines and filled liquid end - when installed correctly. 63

64 Technical data HP2a at 60 Hz operation Type Minimum pump capacity at maximum back pressure Maximum stroke rate bar psi l/h gph Strokes/ min Suction lift Permissible priming pressure, suction side m WS bar G-DN Connector size * 100 1, Rp 3/8" * 100 1, Rp 3/8" * 100 1, Rp 3/8" * 100 1, Rp 3/8" G 3/4" G 3/4" G 3/4" G 3/4" G 3/4" - 10 ** G 3/4" G 3/4" G 3/4" - 10 * Material version SST / HCT with double ball valve Alternative double ball valve SST with RP 3/8 ** HV design G1-DN 15 Maximum back pressure for liquid ends in material version PVT: 25 bar! The metering capacity can deviate from the details above with the HV version. All figures refer to water at 20 C. Priming lift / priming pressure (dry) determined for empty suction line and empty liquid end and as well as clean and moistened valves (the figures are lower with valve springs). The suction lift / suction pressure applies to filled suction lines and filled liquid end - when installed correctly. 64

65 Technical data HP3a at 50 Hz operation Type Minimum pump capacity at maximum back pressure Maximum stroke rate Suction lift Permissible priming pressure, suction side bar l/h ml/stroke Strokes/min m WS bar G-DN Connector size * Rp 3/8" * Rp 3/8" * Rp 3/8" * Rp 3/8" * Rp 3/8" G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 1" - 10 *** G 1" - 10 *** G 1" - 10 *** G 1" - 10 *** G 1" - 10 *** * Material version SST / HCT with double ball valve Alternative double ball valve SST with RP 3/8 ** HV design 1 1/4" - DN 20 *** HV version G 1" - DN 15 Maximum back pressure for liquid ends in material version PVT: 25 bar! The metering capacity can deviate from the details above with the HV version. All figures refer to water at 20 C. Priming lift / priming pressure (dry) determined for empty suction line and empty liquid end and as well as clean and moistened valves (the figures are lower with valve springs). The suction lift / suction pressure applies to filled suction lines and filled liquid end - when installed correctly. 65

66 Technical data HP3a at 60 Hz operation Type Minimum pump capacity at maximum back pressure Maximum stroke rate bar psi l/h gph Strokes/ min Suction lift Permissible priming pressure, suction side Connector size m WS bar G-DN * 100 1, Rp 3/8" * 100 1, Rp 3/8" * 100 1, Rp 3/8" * 100 1, Rp 3/8" G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 3/4" - 10 ** G 1" - 10 *** G 1" - 10 *** G 1" - 10 *** G 1" - 10 *** * Material version SST / HCT with double ball valve Alternative double ball valve SST with RP 3/8 ** HV design 1 1/4" - DN 20 *** HV version G 1" - DN 15 Maximum back pressure for liquid ends in material version PVT: 25 bar! The metering capacity can deviate from the details above with the HV version. All figures refer to water at 20 C. Priming lift / priming pressure (dry) determined for empty suction line and empty liquid end and as well as clean and moistened valves (the figures are lower with valve springs). The suction lift / suction pressure applies to filled suction lines and filled liquid end - when installed correctly Metering reproducibility Data Value Unit Reproducibility ±1 % * * for measurements taken under constant conditions, minimum 20 % stroke rate and water at 20 C - when installed correctly and with a back pressure of at least 1.5 bar 13.3 Viscosity The liquid ends are suitable for the following viscosity ranges: 66

67 Technical data Design Range Unit no valve springs mpas with valve springs mpas HV (for highly viscous feed chemicals) approx * mpas * Only when the installation is correctly adjusted 13.4 Weight For SST material version pumps with standard motor. Pump Design Weight kg HP2a Single head 31 Double head 41 Add-on power end 24 Add-on power end double head 34 HP3a Single head 41 Double head 55 Add-on power end 34 Add-on power end double head Wetted materials Material version Liquid end Suction/pressure connector Seals Ball seat Valve balls SST Stainless steel // / Stainless steel PTFE ZrO2 Ceramic PVT PVDF PVDF PTFE PTFE Ceramic HCT Hastelloy C Hastelloy C PTFE Hastelloy C Ceramic 13.6 Ambient conditions Temperatures Pump, compl. Data Value Unit Storage and transport temperature C Ambient temperature in operation ("Standard" version, for drive): Ambient temperature in operation ("Low temperature" version, for drive): Ambient temperature in operation ("Low temperature Zone 2" version, for drive): C C C 67

68 Technical data * Only with heating heating cartridge PVT - ATEX liquid end Data Value Unit Max. temperature, long-term at max. operating pressure 65 C Minimum temperature "Standard" -10 C Minimum temperature "Low temperature Zone 2" -20 C PVT liquid end Data Value Unit Max. temperature, long-term at max. operating pressure 65 C Max. temperature, for 15 min at max. 2 bar 100 C Minimum temperature "Standard" -10 C Minimum temperature "Low temperature Zone 2" -20 C Minimum temperature "Low temperature" -25 C HCT - ATEX liquid end Data Value Unit Max. temperature, long-term at max. operating pressure 90 C Minimum temperature "Standard" -10 C Minimum temperature "Low temperature Zone 2" -20 C HCT liquid end Data Value Unit Max. temperature, long-term at max. operating pressure 90 C Max. temperature, for 15 min at max. 2 bar 120 C Minimum temperature "Standard" -10 C Minimum temperature "Low temperature Zone 2" -20 C Minimum temperature "Low temperature" -25 C SST - ATEX liquid end Data Value Unit Max. temperature, long-term at max. operating pressure 90 C Minimum temperature "Standard" -10 C Minimum temperature "Low temperature Zone 2" -20 C SST liquid end Data Value Unit Max. temperature, long-term at max. operating pressure 90 C 68

69 Technical data Data Value Unit Max. temperature, for 15 min at max. 2 bar 120 C Minimum temperature "Standard" -10 C Minimum temperature "Low temperature Zone 2" -20 C Minimum temperature "Low temperature" -25 C Air humidity Data Value Unit Maximum air humidity*: 92 % relative humidity *non-condensing (according to DIN IEC ) 13.7 Installation height Data Value Unit Maximum installation height*: 1000 m above standard zero * Fit at higher installation heights at your own risk. We urgently advise that you contact a specialist for ATEX motors when using ATEX pumps! 13.8 Housing degree of protection Data Value Protection against contact and humidity* IP 55 *according to DIN VDE 470 (EN IEC 60529) 13.9 Motor data Electrical Data HP2 and HP3 Identity code specification Phase, protection Rated voltage Mains supply frequency S 3-phase, IP V / V V / V L1 3 ph, II2GEEXeIIT V / V L2 3 ph, II2GEEXdIICT V / V P1 3 ph, II2GEEXeIIT V / V Rated output HP2a 50 Hz 0.37 kw 60 Hz 0.37 kw 50 Hz 0.37 kw Remarks 50 Hz 0.37 kw with PTC, speed control range 1:5 60 Hz 0.37 kw 69

70 Technical data Identity code specification P2 Phase, protection Rated voltage Mains supply frequency 3 ph, II2GEEXdIICT V / V Rated output HP2a Remarks 60 Hz 0.37 kw with PTC, speed control range 1:5 R/Z 3-phase, IP V / 400 V 50/60 Hz 0.37 kw with PTC, speed control range 1:20 with external fan 1- ph 230 V; 50/60 Hz V0 1 ph AC, IP V ±10% 50/60 Hz 0.37 kw Variable speed motor with integrated frequency converter V2 3 ph, II2GEEXdIICT4 400 V ±10% 50/60 Hz 0.55 kw EX variable speed motor with integrated frequency converter. HP3 Identity code specification Phase, protection Rated voltage Mains supply frequency S 3-phase, IP V / V V / V L1 3 ph, II2GEEXeIIT V / V L2 3 ph, II2GEEXdIICT V / V P1 3 ph, II2GEEXeIIT V / V P2 3 ph, II2GEEXdIICT V / V Rated output 50 Hz 0.75 kw 60 Hz 0.75 kw 50 Hz 0.75 kw Remarks 50 Hz 0.75 kw with PTC, speed control range 1:5 60 Hz 0.75 kw 60 Hz 0.75 kw with PTC, speed control range 1:5 R/Z 3-phase, IP V / 400 V 50/60 Hz 0.75 kw with PTC, speed control range 1:20 with external fan 1- ph 230 V; 50/60 Hz V0 1 ph AC, IP V ±10% 50/60 Hz 0.75 kw Variable speed motor with integrated frequency converter V2 3 ph, II2GEEXdIICT4 400 V ±10% 50/60 Hz EX variable speed motor with integrated frequency converter. Motor data sheets, special motors, special motor flanges, external fan, temperature monitoring For further information for the motor with identity code specification "S", refer to the motor data sheet in the Appendix. Motor data sheets can be requested for all other motors. For other motors than those with identity code specification "S": Pay special attention to the operating instructions for the motors. Special motors or special motor flanges are possible on request. 70

71 Technical data Diaphragm rupture sensor Install the sensor according to the chapter "Installation, electrical". Contact (standard) Contact loading, max. at voltage Maximum current 30 V DC 1 A The contact is an opener. The contact is an potential-free. For safety reasons we recommend connecting to a protective low voltage, e.g. in accordance with EN (SELV ). The cable can be poled as required. Install the sensor according to the chapter "Installation, electrical". Observe its documentation. Sensor name: NJ1.5-8GM-N. : Namur sensor (Specified for EX zones) 5 25 V DC, in accordance with Namur or DIN 19234, potential-free design. Data Value Unit Rated voltage * 8 VDC Power consumption - active surface uncovered Power consumption - active surface covered > 3 ma < 1 ma Rated switching distance 1.5 mm * Ri ~ 1 kω Cable colour Polarity blue - brown + Install the sensor according to the chapter "Installation, electrical". Observe its documentation. The sensor is of type NJ1,5-8GM-N. 71

72 Technical data Safety relief valve (HP2 and HP3) Opening pressure of the respective pressure rating: Pressure stage* 6 bar 10 bar 16 bar 25 bar 40 bar 64 bar 100 bar Opening pressure** 10 bar 14 bar 25 bar 36 bar 50 bar 80 bar 120 bar * Marking on the indicating scale without valve housing ** back pressure generated by the pump when discharge side is blocked ± 3 bar Stroke sensor Namur sensor (identity code characteristic "stroke sensor": 1) Install the sensor according to the chapter "Installation, electrical". Namur sensor (Specified for EX zones) 5 25 V DC, in accordance with Namur or DIN 19234, potential-free design. Data Value Unit Rated voltage * 8 VDC Power consumption - active surface uncovered Power consumption - active surface covered > 3 ma < 1 ma Rated switching distance 1.5 mm * Ri ~ 1 kω Cable colour Polarity blue - brown + Install the sensor according to the chapter "Installation, electrical". Observe its documentation. The sensor is of type NJ1,5-8GM-N Heating cartridge Technical data - see enclosed operating instructions 72

73 Technical data Protection temperature limiter (ATEX only) Technical data - see enclosed operating instructions Filling volumes Hydraulic oil Required amount of oil Type Single-head design Double head version HP 2: approx. 2.5 l approx. 2.9 l 3.0 l HP 3: approx. 3.5 l approx. 4.0 l 4.0 l Supplied amount of oil Use Manufacturer Name Viscosity class Part no. Standard Mobil Mobilube 1 SHC * 75W * or comparable hydraulic oil Use Manufacturer Name Viscosity class Part no. Food Mobil SHC Cibus * * or comparable hydraulic oil Sound pressure level HP2a / Hp3a Sound pressure level Sound pressure level LpA < 70 db according to EN ISO at maximum stroke length, maximum stroke rate, maximum back pressure (water) Supplement for modified versions (With Identcode specification "Version": "M" - "modified") Technical data Technical data of pumps in the modified version can deviate from those of the standard pumps. They can be queried by stating the details of the serial number. motor The motor data sheets for the modified version are valid. They may deviate from the standard motor data sheets. Spare parts With a modified version, it is absolutely necessary to specify the details of the serial number requesting and ordering the spare and replacement parts. 73

74 Ordering Information 14 Ordering Information 14.1 Exploded view of the drawing * 4 P_HY_0017_SW Fig. 23: Exploded view of Hydro liquid end Numbered positions = PVT set of spare parts - range for supply. Technical changes reserved. 1 Seals (Set) 2 Valve balls 3 Pressure connection assy. 4 Suction connection assy. 5 Diaphragm * Reinforce plate - only with PVT 14.2 Spare parts kits The spare part kits include the replacement parts for the liquid ends. Standard delivery for material version PVT 1 - Diaphragm 1 - Suction connection assy. 1 - Pressure connection assy. 2 - Valve balls 1 - Set of seals, compl. Standard delivery for material version SST / HCT 1 - Diaphragm 2 - Valve balls 1 - Set of seals, compl. 74

75 Ordering Information Spare parts kits Hydro/ 2 for types: , , , , , , , , , : for liquid end Material version Order no. FMH 25 - DN 10 PVT SST SST (for double ball valves) HCT SST (with valves, fully assembled) for types: , , , , : for liquid end Material version Order no. FMH 60 - DN 10 PVT SST SST (for double ball valves) HCT SST (with valves, fully assembled) Spare parts kits Hydro/ 3 for types: , , , , , , , , , : for liquid end Material version Order no. FMH 60 - DN 10 PVT SST SST (for double ball valves) HCT SST (with valves, fully assembled) for types: , , , , : for liquid end Material version Order no. FMH DN 15 PVT SST HCT SST (with valves, fully assembled)

76 Ordering Information 14.3 Diaphragms Metering diaphragm PTFE for liquid end Pump type Order no. FMH , , , , , , , , FMH , , , , Metering diaphragm PTFE / Hastelloy C, coated for liquid end Pump type Order no. FMH , , , , FMH , , , , Metering diaphragm PTFE for liquid end Pump type Order no. FMH , , , , , , , , FMH , , , , Metering diaphragm PTFE / Hastelloy C, coated for liquid end Pump type Order no. FMH , , , , , , , , FMH , , , , General Hydraulic oil The pump uses an hydraulic oil that lubricates the gear at the same time. Use Manufacturer Name Viscosity class Part no. Standard Mobil Mobilube 1 SHC * 75W * or comparable hydraulic oil Use Manufacturer Name Viscosity class Part no. Food Mobil SHC Cibus * * or comparable hydraulic oil 76

77 Ordering Information Required amount of oil Type Single-head design Double head version HP 2: approx. 2.5 l approx. 2.9 l 3.0 l HP 3: approx. 3.5 l approx. 4.0 l 4.0 l Supplied amount of oil Seal Spare part Order no. Seal for the oil drainage stopper

78 Dimensional Drawings 15 Dimensional Drawings Compare the dimensions on the dimension sheet and pump. All dimensions are in mm. Hydro HP2 (HP2a H) dimensions sheet E A L F F 12 C B D _02-101_00_01-73 P_HY_0019_SW G Fig. 24: Diagram is not binding. Liquid end A B C D E F G HM 25 SST, HCT DN10G3/4A 108x HM 60 SST, HCT DN10G3/4A 108x HM 60 SST-HV DN15G1A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , ,

79 Dimensional Drawings Liquid end A B C D E F G HM 25 PVT DN10G3/4A 108x HM 60 PVT DN10G3/4A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , , Dimension with double ball valve Liquid end A B C D E G HM 25 SST, HCT DN10Rp3/8" 418 HM 60 SST, HCT DN10Rp3/8" 419 Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP3 (HP3a H) dimensions sheet E A L F 12 C B D _02-101_00_02-73 P_HY_0020_SW G Fig. 25: Diagram is not binding. Liquid end A B C D E F G HM 60 SST, HCT DN10G3/4A 108x HM 150 SST, HCT DN15G1A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , ,

80 Dimensional Drawings Liquid end A B C D E F G HM 60 SST-HV DN15G1A 108x HM 150 SST-HV DN20G1 1/4A 128x HM 60 PVT DN10G3/4A 108x HM 150 PVT DN15G1A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , , Dimension with double ball valve Liquid end A B C D E G HM 60 SST, HCT DN10Rp3/8" 461 Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP2 (HP2a H) dimensions sheet, double head version (HP2a D) E C 83 A L _02-101_00_03-73 P_HY_0021_SW F Fig. 26: Diagram is not binding B 496 H G D Liquid end A B C D E F G H HM 25 SST, HCT DN10G3/4A 108x HM 60 SST, HCT DN10G3/4A 108x HM 60 SST-HV DN15G1A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , ,

81 Dimensional Drawings Liquid end A B C D E F G H HM 25 PVT DN10G3/4A 108x HM 60 PVT DN10G3/4A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , , Dimension with double ball valve Liquid end A B C D E G H HM 25 SST, HCT DN10Rp3/8" HM 60 SST, HCT DN10Rp3/8" Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP3 dimensions sheet, double head version (HP3a D) E C 95 A L _02-101_00_04-73 P_HY_0022_SW F B 540 H G D Fig. 27: Diagram is not binding. Liquid end A B C D E F G H HM 60 SST, HCT DN10G3/4A 108x HM 150 SST, HCT DN15G1A 128x HM 60 SST-HV DN15G1A 108x HM 150 SST-HV DN20G1 1/4A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , ,

82 Dimensional Drawings Liquid end A B C D E F G H HM 60 PVT DN10G3/4A 108x HM 150 PVT DN15G1A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , , Dimension with double ball valve Liquid end A B C D E G H HM 60 SST, HCT DN10Rp3/8" Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP2 dimensions sheet with add-on drive (HP2a E + HP2a A) E C 133 A L D F B 61_02-101_00_09-74 P_HY_0023_SW G Fig. 28: Diagram is not binding. Liquid end A B C D E F G HM 25 SST, HCT DN10G3/4A 108x HM 60 SST, HCT DN10G3/4A 108x HM 60 SST-HV DN15G1A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , ,

83 Dimensional Drawings Liquid end A B C D E F G HM 25 PVT DN10G3/4A 108x HM 60 PVT DN10G3/4A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , , Dimension with double ball valve Liquid end A B C D E G HM 25 SST, HCT DN10Rp3/8" 448 HM 60 SST, HCT DN10Rp3/8" 449 Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP3 dimensions sheet with add-on drive (HP3a E + HP3a A) 61_02-101_00_13-74 P_HY_0024_SW Fig. 29: Diagram is not binding. Liquid end A B C D E F G HM 60 SST, HCT DN10G3/4A 108x HM 150 SST, HCT DN15G1A 128x HM 60 SST-HV DN15G1A 108x "HM 60" for types , , , , , , , , , "HM 150" for types , , , ,

84 Dimensional Drawings Liquid end A B C D E F G HM 150 SST-HV DN20G1 1/4A 128x HM 60 PVT DN10G3/4A 108x HM 150 PVT DN15G1A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , , Dimension with double ball valve Liquid end A B C D E G HM 60 SST, HCT DN10Rp3/8" 499 Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP2 dimensions sheet with add-on drive, double-head versions (HP2a F + HP2a B) 61_02-101_00_10-74 P_HY_0025_SW Fig. 30: Diagram is not binding. Liquid end A B C D E F G H HM 25 SST, HCT DN10G3/4A 108x HM 60 SST, HCT DN10G3/4A 108x HM 60 SST-HV DN15G1A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , ,

85 Dimensional Drawings Liquid end A B C D E F G H HM 25 PVT DN10G3/4A 108x HM 60 PVT DN10G3/4A 108x "HM 25" for types , , , , , , , , , "HM 60" for types , , , , Dimension with double ball valve Liquid end A B C D E G H HM 25 SST, HCT DN10Rp3/8" HM 60 SST, HCT DN10Rp3/8" Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L Hydro HP3 dimensions sheet with add-on drive, double-head versions (HP3a F + HP3a B) 61_02-101_00_14-74 P_HY_0026_SW Fig. 31: Diagram is not binding. Liquid end A B C D E F G H HM 60 SST, HCT DN10G3/4A 108x HM 150 SST, HCT DN15G1A 128x HM 60 SST-HV DN15G1A 108x HM 150 SST-HV DN20G1 1/4A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , ,

86 Dimensional Drawings Liquid end A B C D E F G H HM 60 PVT DN10G3/4A 108x HM 150 PVT DN15G1A 128x "HM 60" for types , , , , , , , , , "HM 150" for types , , , , Dimension with double ball valve Liquid end A B C D E G H HM 60 SST, HCT DN10Rp3/8" Standard motor Motor, controllable EExe motor EExde motor Motor with frequency converter L

87 Earthing drawing 16 Earthing drawing Simplex single head Hydro HP2 and HP3 with actuator and heating cartridge P_HY_0044_SW 2 Motor 3 Heating cartridge (option) 6 Actuator 87

88 EC Declaration of Conformity for Machinery 17 EC Declaration of Conformity for Machinery For pumps without explosion protection: In accordance with DIRECTIVE 2006/42/EC OF THE EUROPEAN PAR LIAMENT AND OF THE COUNCIL, Appendix I, BASIC HEALTH AND SAFETY REQUIREMENTS, section C. We, ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 D Heidelberg, hereby declare that the product specified in the following, complies with the relevant basic health and safety requirements of the EC Directive, on the basis of its functional concept and design and in the version distributed by us. This declaration loses its validity in the event of a modification to the product not agreed with us. Extract from the EC Declaration of Conformity Designation of the product: Metering pump product range Hydro 2, Hydro 3 and Hydro 4 Product type: Serial number: Relevant EC directives: Harmonised standards applied, in particular: HP2a... HP3a... HP4a... See nameplate on the unit EC Machinery Directive (2006/42/EC) EC EMC Directive (2004/108/EC) Compliance with the protection targets of the Low Voltage Directive 2006/95/EC according to Appendix I, No of the Machinery Directive 2006/42/EC EN ISO 12100, EN 809 EN EN /4 Date: 30/09/2013 You can find the EC Declaration of Conformity as a download on our homepage. 88

89 EC Declaration of Incorporation for ATEX HP2 Machines 18 EC Declaration of Incorporation for ATEX HP2 Machines We, ProMinent GmbH Im Schuhmachergewann 5-11 D Heidelberg, hereby declare that the product specified in the following, complies with the relevant basic health and safety requirements of the EC Directive, on the basis of its functional concept and design and in the version distributed by us. Technical documents were produced in line with Appendix VII Part B. Any modification to the product not approved by us will invalidate this declaration. Extract from the EC Declaration of Incorporation Designation of the product: Metering pump without motor, product range Hydro 2 Product type: Serial number: Relevant EC directives: Harmonised standards applied, in particular: Design for use in areas at risk of explosion in accordance with the ATEX Directive (94/9/EC) HP2a A - 0 & with the characteristic = "1" or "3" or "4" & = "0" or "1" or "3" see nameplate on the device EC ATEX Directive (94/9/EC) EC Machinery Directive (2006/42/EC) EC EMC Directive (2004/108/EC) Compliance with the protection targets of the Low Voltage Directive 2006/95/EC according to Appendix I, No of the Machinery Directive 2006/42/EC EN :2009, EN :2011 EN ISO 12100:2010, EN 809:1998+A1:2009-AC:2010 EN :2005, EN :2007+A1:2011 EN :2006+A1:2009 Only start up the pump when it has been established that the machine into which the pump has been installed corresponds to the provisions of the Machine Directive. EX specification of the entire system: II 2G IIC T4 X for & = "0" or "1" II 3G IIB T4 X for & = "3" X: maximum medium temperature 90 C Assess the ignition risk when combining the pump and motor. Date: 15/10/2015 You will find the EC Declaration of Incorporation to download on our homepage. 89

90 EC Declaration of Incorporation for ATEX HP3 Machines 19 EC Declaration of Incorporation for ATEX HP3 Machines In accordance with DIRECTIVE 2006/42/EC OF THE EUROPEAN PAR LIAMENT AND OF THE COUNCIL, Appendix I, BASIC HEALTH AND SAFETY REQUIREMENTS, section C. We, ProMinent GmbH Im Schuhmachergewann 5-11 D Heidelberg, hereby declare that the product specified in the following, complies with the relevant basic health and safety requirements of the EC Directive, on the basis of its functional concept and design and in the version distributed by us. Technical documents were produced in line with Appendix VII Part B. Any modification to the product not approved by us will invalidate this declaration. Extract from the EC Declaration of Incorporation Designation of the product: Metering pump without motor, product range Hydro 3 Product type: Serial number: Relevant EC directives: Harmonised standards applied, in particular: Design for use in areas at risk of explosion in accordance with the ATEX Directive (94/9/EC) HP3a A - 0 & with the characteristic = "1" or "3" or "4" & = "0" or "1" or "3" see nameplate on the device EC ATEX Directive (94/9/EC) EC Machinery Directive (2006/42/EC) EC EMC Directive (2004/108/EC) Compliance with the protection targets of the Low Voltage Directive 2006/95/EC according to Appendix I, No of the Machinery Directive 2006/42/EC EN :2009, EN :2011 EN ISO 12100:2010, EN 809:1998+A1:2009+AC2010 EN :2005, EN :2007+A1:2011 EN :2006+A1:2009 Only start up the pump when it has been established that the machine into which the pump has been installed corresponds to the provisions of the Machine Directive. EX specification of the entire system: II 2G IIC T4 X for & = "0" or "1" II 3G IIB T4 X for & = "3" X: maximum medium temperature 90 C Assess the ignition risk when combining the pump and motor. Date: 15/10/2015 You will find the EC Declaration of Incorporation to download on our homepage. 90

91 EC Declaration of Conformity for ATEX HP2 Machines 20 EC Declaration of Conformity for ATEX HP2 Machines In accordance with DIRECTIVE 2006/42/EC OF THE EUROPEAN PAR LIAMENT AND OF THE COUNCIL, Appendix I, BASIC HEALTH AND SAFETY REQUIREMENTS, section C. We, ProMinent GmbH Im Schuhmachergewann 5-11 D Heidelberg, hereby declare that the product specified in the following, complies with the relevant basic health and safety requirements of the EC Directive, on the basis of its functional concept and design and in the version distributed by us. Any modification to the product not approved by us will invalidate this declaration. Extract from the EC Declaration of Conformity Designation of the product: Metering pump, product range Hydro 2 Product type: Serial number: Relevant EC directives: Harmonised standards applied, in particular: EX specification of the entire system: Design for use in areas at risk of explosion in accordance with the ATEX Directive (94/9/EC) HP2a $ - 0 & with characteristics = "L" or "P" and $ = "1" or "2" or = "V" and $ = "2" & = "0" or "1" or "3" Date: 15/10/2015 see nameplate on the device EC ATEX Directive (94/9/EC) EC Machinery Directive (2006/42/EC) EC EMC Directive (2004/108/EC) Compliance with the protection targets of the Low Voltage Directive 2006/95/EC according to Appendix I, No of the Machinery Directive 2006/42/EC EN :2009, EN :2011 EN ISO 12100:2010, EN 809:1998+A1:2009+AC:2010 EN :2005, EN :2007+A1:2011 EN :2006+A1:2009 II 2G IIC T3 X for $ = "1" and & = "0" or "1" II 2G IIC T4 X for $ = "2" and & = "0" or "1" II 3G IIC T3 X for $ = "1" and & = "3" II 3G IIC T4 X for $ = "2" and & = "3" X: maximum medium temperature 90 C You will find the EC Declaration of Conformity to download on our homepage. 91

92 EC Declaration of Conformity for ATEX HP3 Machines 21 EC Declaration of Conformity for ATEX HP3 Machines In accordance with DIRECTIVE 2006/42/EC OF THE EUROPEAN PAR LIAMENT AND OF THE COUNCIL, Appendix I, BASIC HEALTH AND SAFETY REQUIREMENTS, section C. We, ProMinent GmbH Im Schuhmachergewann 5-11 D Heidelberg, hereby declare that the product specified in the following, complies with the relevant basic health and safety requirements of the EC Directive, on the basis of its functional concept and design and in the version distributed by us. Any modification to the product not approved by us will invalidate this declaration. Extract from the EC Declaration of Conformity Designation of the product: Metering pump, product range Hydro 3 Product type: Serial number: Relevant EC directives: Harmonised standards applied, in particular: EX specification of the entire system: Design for use in areas at risk of explosion in accordance with the ATEX Directive (94/9/EC) HP3a $ - 0 & with characteristics = "L" or "P" and $ = "1" or "2" or = "V" and $ = "2" & = "0" or "1" or "3" Date: 15/10/2015 see nameplate on the device EC ATEX Directive (94/9/EC) EC Machinery Directive (2006/42/EC) EC EMC Directive (2004/108/EC) Compliance with the protection targets of the Low Voltage Directive 2006/95/EC according to Appendix I, No of the Machinery Directive 2006/42/EC EN :2009, EN :2011 EN ISO 12100:2010, EN 809:1998+A1:2009+AC:2010 EN :2005, EN :2007+A1:2011 EN :2006+A1:2009 II 2G IIC T3 X for $ = "1" and & = "0" or "1" II 2G IIC T4 X for $ = "2" and & = "0" or "1" II 3G IIC T3 X for $ = "1" and & = "3" II 3G IIC T4 X for $ = "2" and & = "3" X: maximum medium temperature 90 C You will find the EC Declaration of Conformity to download on our homepage. 92

93 Diagrams for setting the metering capacity 22 Diagrams for setting the metering capacity Hydro/ 2 HP2a H C [l/h] C [l/h] s [%] s [%] C [l/h] C [l/h] p [bar] p [bar] C [l/h] s [%] C [l/h] p [bar] 30 Fig. 32: Metering capacity C at medium back pressure according to the stroke length s and metering capacity C on the basis of back pressure p for different types of a series. 93

94 Diagrams for setting the metering capacity C [l/h] Hydro/ 3 HP3a H C [l/h] s [%] C [l/h] s [%] C [l/h] p [bar] p [bar] C [l/h] C [l/h] s [%] p [bar] 30 Fig. 33: Metering capacity C at medium back pressure according to the stroke length s and metering capacity C on the basis of back pressure p for different types of a series. 94

95 95

96 ProMinent GmbH Im Schuhmachergewann Heidelberg Germany Telephone: Fax: Internet: Heidelberg, 7, en_gb 2010

Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4

Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4 Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4 Two sets of operating instructions are required for the safe, correct and proper operation of the ProMinent Hydro metering pumps: These

More information

Operating instructions Diaphragm Metering Pump Makro TZ, TZMb

Operating instructions Diaphragm Metering Pump Makro TZ, TZMb Operating instructions Diaphragm Metering Pump Makro TZ, TZMb P_MA_0022_SW Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any damage caused

More information

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Basic Type S1Ba

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Basic Type S1Ba Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Basic Type S1Ba P_SI_0039 Please carefully read these operating instructions before use! Do not discard! The operator shall be liable

More information

Operating instructions Diaphragm Metering Pump ProMinent Makro/ 5 M5Ma

Operating instructions Diaphragm Metering Pump ProMinent Makro/ 5 M5Ma Operating instructions Diaphragm Metering Pump ProMinent Makro/ 5 M5Ma Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any damage caused

More information

Operating instructions Piston Metering Pump Makro TZ, TZKa

Operating instructions Piston Metering Pump Makro TZ, TZKa Operating instructions Piston Metering Pump Makro TZ, TZKa P_MA_0019_SW Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any damage caused

More information

Operating instructions Diaphragm Metering Pump Makro TZ, TZMb

Operating instructions Diaphragm Metering Pump Makro TZ, TZMb Operating instructions Diaphragm Metering Pump Makro TZ, TZMb P_MA_0022_SW Two sets of operating instructions are required for the safe, correct and proper operation of the metering pumps: The product-specific

More information

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma / 3 Base Type S3Ba

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma / 3 Base Type S3Ba Operating instructions Diaphragm Motor-Driven Metering Pump Sigma / 3 Base Type S3Ba P_SI_0075_SW Two sets of operating instructions are required for the safe, correct and proper operation of the metering

More information

Operating instructions Hydraulic diaphragm metering pump ProMinent Makro/ 5 M5Ha

Operating instructions Hydraulic diaphragm metering pump ProMinent Makro/ 5 M5Ha Operating instructions Hydraulic diaphragm metering pump ProMinent Makro/ 5 M5Ha Two sets of operating instructions are required for the safe, correct and proper operation of the metering pumps: The product-specific

More information

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Control Type S1Cb

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Control Type S1Cb Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Control Type S1Cb Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any

More information

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Control Type S1Cb

Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Control Type S1Cb Operating instructions Diaphragm Motor-Driven Metering Pump Sigma/ 1 Control Type S1Cb Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 , IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS FF 20 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FF 20 DCB-4 FF 20 DC-M Before operating the pump and the accessories, please read the Installation Instructions and safety precautions. Installation Instructions

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions , IECEx EPS 16.0053X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions. FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC-P FL 10 AC Before operating the pump, please read the Installation Instructions and safety precautions. Installation Instructions FL 10 Table of

More information

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 5411, 5413 3/2 or 4/2 way solenoid valve 3/2 oder 4/2-Wege-Magnetventil Électrovanne 3/2 ou 4/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 THE OPERATING INSTRUCTIONS The

More information

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 , IECEx PTB 14.0049X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

DIAPHRAGM LIQUID PUMP NF 1.30

DIAPHRAGM LIQUID PUMP NF 1.30 DIAPHRAGM LIQUID PUMP NF 1.30 NF 1.30 KT DCG 12V Supply voltage [Ch. 4] DCG KT / TT [Ch. 4] 1.30 NF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these Operating

More information

DIAPHRAGM LIQUID PUMP NF 2.35

DIAPHRAGM LIQUID PUMP NF 2.35 DIAPHRAGM LIQUID PUMP NF 2.35 NF 2.35 XP DC 24V Supply voltage [Ch. 4] DCB-A XP / XT [Ch. 4] 2.35 NF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these Operating

More information

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps UNPK04DC Pressure UNPK04DCB Pressure UNPK04DC Vacuum UNPK04DCB Vacuum KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ

More information

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI Type FSO, FSO-GR, FS, HPI Hatschekstr.36 69126 Heidelberg Deutschland Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 23.08.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\M1124E_0_FSO_FSO-GR_FS_HPI.docx

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Wilo-Control SC-Fire Jockey

Wilo-Control SC-Fire Jockey Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016 Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex Operating Instructions

More information

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 6027 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01 PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Micro diaphragm liquid pump NF 25 NFB 25

Micro diaphragm liquid pump NF 25 NFB 25 Micro diaphragm liquid pump NF 25 NFB 25 NF 25 KP DC-M 12V Supply voltage [Ch. 4] DC-M / DC-L / DCB-4 / DCB-4A KP / KT / TT [Ch. 4] 25 NF / NFB - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions

More information

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Turbocharger / VTR..0, VTR..1 Original assembly instructions English Assembly Instructions Turbocharger / VTR..0, VTR..1 Original assembly instructions English This document is valid for the VTR..0/..1 series: VTR160, VTR200, VTR250, VTR320, VTR400 VTR161, VTR201, VTR251,

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

Operating Instructions Flexdip CYA112

Operating Instructions Flexdip CYA112 BA00432C/07/EN/13.13 71207066 Products Solutions Services Operating Instructions Wastewater assembly About this document Safety messages The structure, signal words and safety colors of the signs comply

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

ProMinent Hydro Hydraulic Diaphragm Metering Pumps

ProMinent Hydro Hydraulic Diaphragm Metering Pumps ProMinent Hydro Hydraulic Diaphragm Metering Pumps ProMinent Hydro Hydraulic Diaphragm Metering Pumps NEW hydraulic motor driven metering pumps provide precise and safe metering for high pressure applications.

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

Micro diaphragm liquid pump NF 1.5 NFB 5

Micro diaphragm liquid pump NF 1.5 NFB 5 Micro diaphragm liquid pump NF 1.5 NFB 5 NF 1.5 KP DC-M 12V Supply voltage [Ch. 4] DC-M / DCB-4 KP / KT / TT [Ch. 4] 1.5 / 5 NF / NFB - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions

More information

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s.   PEGAS E Smart Manual EN 04 WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP 03 KP DC-B1 NMP 03 KP DC-S NMP 03 KP DC-B3 NMP 03 KP DC-M NMP 03 KP DC-L You have selected a high-quality KNF

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds for assembly, commissioning and maintenance of valves and hydraulic manifolds 110210_general_operating_manual 07.2018 Table of contents Contents Page Important information 2 Important safety instructions

More information

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump Electric control valves with jet pump Type 3267/5824, Type 3267/5825, Type 3267/3374, Type 3267/3274 Pneumatic control valves with jet pump Type 3267-1, Type 3267-7 Flanged version of valve with jet pump

More information

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Operating manual. Custom made gearboxes

Operating manual. Custom made gearboxes Operating manual Custom made gearboxes DSS-Nr. 100389549 DSS-Rev. 001 Datum 16.01.2018 Contents Contents 1 General information 3 1.1 Using the operating manual 3 1.2 Warnings in this operating manual 4

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 050 NPK 0100 Operating and Installation Instructions Read and observe these Operating and Installation Instructions! KNF Neuberger GmbH Alter Weg 3 D-79112

More information

Please affix device label here!

Please affix device label here! Operating Instructions MTMa (Diaphragm Dosing Pumps) MTKa (Piston Dosing Pumps) MTMa MTKa Please affix device label here! For safe and correct operation of dosing pumps, two sets of Operating Instructions

More information

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning. Declaration of Conformity Operating Instructions Rolli D6/5A 440209101-A 03/2004 Subject to technical alterations. Text and design copyrighted. Reprinting and copying, even if excerpts, only with written

More information

Turbocharger / A100-L Original assembly instructions English

Turbocharger / A100-L Original assembly instructions English Assembly Instructions Turbocharger / A100-L Original assembly instructions English This document is valid for the A100-L series: A165-L, A170-L, A175-L, A180-L, A185-L, A190-L Purpose The assembly instructions

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

DIAPHRAGM LIQUID PUMP NF 1.25

DIAPHRAGM LIQUID PUMP NF 1.25 DIAPHRAGM LIQUID PUMP NF 1.25 NF 1.25 RP DC 12V Supply voltage [Ch. 4] DC / DCB-4A RP / RT [Ch. 4] 1.25 NF / UNF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type 3320, Service Manual. Serviceanleitung Service Manuel Electromotive 2/2-way valve Elektromotorisches 2/2-Wege-Ventil Vanne électromotorisée à 2/2 voies Service Manual Serviceanleitung Service Manuel We reserve the right to make technical changes without notice.

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP830K_DC-M HP NMP830.1.2K_DC-M HP NMP830K_DC-B HP NMP830.1.2K_DC-B HP NMP830K_DC-B4 HP NMP830.1.2K_DC-B4 HP You

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Installation and Operation Manual

Installation and Operation Manual Industrial Process Installation and Operation Manual Advantage Actuator 2.0 Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2 Transportation

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019 Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon: +49(0)7135-102-0 Service: +49(0)7135-102-211 Telefax: +49(0)7135-102-147 E-Mail:

More information

Operating Instructions CYR52

Operating Instructions CYR52 BA01300C/07/EN/02.14 71261315 Products Solutions Services Operating Instructions CYR52 Ultrasonic cleaning Document information Warnings The structure, signal words and safety colors of the signs comply

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

RESOL SBS 1000 * * Connection Operation

RESOL SBS 1000 * * Connection Operation RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information

Hydraulic Immediate Need Power Pack

Hydraulic Immediate Need Power Pack Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read

More information

DIAPHRAGM LIQUID PUMP NF 10, NF 11, NF 1.11

DIAPHRAGM LIQUID PUMP NF 10, NF 11, NF 1.11 DIAPHRAGM LIQUID PUMP NF 10, NF 11, NF 1.11 NF 10 KP.51 DC 12V Supply voltage [Section 4] DC / DCB / E.51 / - [Section. 2] KP / KT / KV / TT / TV [Section. 4] 10 / 11 / 1.11 NF / JNF - / PMLxxxx / PLxxxx

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds

More information

Operator s and Maintenance Manual

Operator s and Maintenance Manual Industrial Cleaning Machines Floor Scrubbers - Battery Version Operator s and Maintenance Manual HAZAN ISI VE MAKİNA SANAYİ LTD. ŞTİ. KISIKLI CAD.NO.79 ALTUNIZADE 34662 İSTANBUL-TÜRKİYE TEL : +90 216 321

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LB

Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LB Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LB Read the operating instructions! The user is responsible for installation and operation related mistakes! Original Dosing Conveying Control Liquids

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Installation and Operating Instructions Magnetic Vibrator MR 1

Installation and Operating Instructions Magnetic Vibrator MR 1 Installation and Operating Instructions Magnetic Vibrator MR 1 (Translation of the Original Instruction Manual) Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 999824-00

More information

Operating Instructions Makro TZ Metering Pumps

Operating Instructions Makro TZ Metering Pumps ProMinent Operating Instructions Makro TZ Metering Pumps Makro TZMb Makro TZMa Makro TZHa Makro TZKa TZMb TZMa TZHa TZKa Please enter identcode of the device here. Two operating instruction manuals are

More information

Supplementary instructions Sigmas with hygienic pump head

Supplementary instructions Sigmas with hygienic pump head Supplementary instructions Sigmas with hygienic pump head EN Two sets of operating instructions are required for the safe, correct and proper operation of the metering pumps: this set of supplementary

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Sinewave Inverters. SWING 150VA and 300VA. User s manual Sinewave Inverters SWING 150VA and 300VA User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimension s rely on information s given by the manufacturer.

More information

Pumps and pumping units SL i & Micro C

Pumps and pumping units SL i & Micro C INSTRUCTIONS 1071 e Section Effective October 2016 Replaces April 2016 Original instructions Additional instructions for ATEX certified equipment Pumps and pumping units SL i & Micro C Дистрибутор: България,

More information

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with diaphragm actuator VZXA-...-M Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information