dinodos DDE Diaphragm dosage pump Installation and Operating Instructions /1012/en

Size: px
Start display at page:

Download "dinodos DDE Diaphragm dosage pump Installation and Operating Instructions /1012/en"

Transcription

1 Operating Instructions Vodes UD with acid flushing dinodos DDE Diaphragm dosage pump /1012/en Installation and Operating Instructions

2 Operating InstructionsGeneral Notes: dinotec GmbH. Water and Pool Technology Spessartstr Maintal/Germany Tel.: Fax: Internet: Subject to technical changes. Errors excepted. Author: B. Dötsch Date:

3 Operating InstructionsGeneral Content 1 General Declaration of Conformity General Notes in bold Warranty Qualification and training of personnel Safety of the system in case of failure of the dosage pump Dosing of chemicals 7 2 General description Intended use(s) Improper operating methods Device overview 9 3 Technical data Dimensions 12 4 Assembly and installation Pump assembly Hydraulic connection Electrical connection 15 5 Commissioning General information Checks to be carried our before commissioning Starting and deaerating the pump 17 6 Operation Operating elements Operating modes Signal inputs 20 7 Service Service intervals Perform service Repair 23 8 Spares 23 9 Error Signalling of faults List of errors/faults Disposal 26 3

4 Operating InstructionsGeneral 1 General 1.1 Declaration of Conformity We, dinotec GmbH, declare under our sole responsibility that the product dinodos DDE, to which this declaration relates, is in conformity with the following Council Directives on the approximation of the laws of the EU Member States: - Machine directive (2006/42/EC) Used standards: EN 809: 1998, EN ISO A1: 2009, EN ISO A1: Low voltage directive (2006/95/EC)* Used standard: EN A1: EMC Directive (2004/108/EC) Used standards: EN : 2005, EN : Only for products with operating voltages > 50 V AC or > 75 V DC. Maintal, November 12th, 2012 Ralph Ziegler Managing Director dinotec GmbH Water and Pool Technology Spessartstr Maintal/Germany Tel.: Fax: mail@dinotec.de Internet: The undersigned person is responsible for the compilation of the technical documentation and authorized to sign the Declaration of CE conformity. 4

5 Operating InstructionsGeneral 1.2 General These installation and operating instructions contain general instructions that must be observed during installation, commissioning, operation, monitoring, maintenance and decommissioning of the pump. It must therefore be read by the installation engineer and the relevant qualified operator prior to installation and start-up, and must be available at the installation location at all times. The operating instructions on hand do not take location-specific regulations into account. The responsibility for observance of these regulations lies with the operator, also in respect of the assembly personnel that is assigned! In case that you should require additional information or details, for example in the event of damage, please contact the service department of dinotec GmbH. This manual contains all instructions for the installation, commissioning, maintenance and repair of the dinodos DEE pump. The safety instructions and notes in bold type are to be observed at all times! Non-observance of the safety instructions can have dangerous consequences for personnel, the environment and the pump, and will result in a loss of any claims for damages. Failure to comply with the instructions may result in the following hazards: - Personal injury from exposure to electrical, mechanical and chemical influences. - Damage to the environment and personal injury from leakage of harmful substances. 1.3 Notes in bold In this technical information, the bold headings Caution, Warning and Note have the following meaning: Caution: This heading is used if failure to observe the operating or working instructions or prescribed procedures, or incorrect observation of such instructions and the like can lead to accident or personal injury. This heading is used if failure to observe the operating or working instructions or prescribed procedures, or incorrect observation of such instructions and the like can lead to damage to the equipment. Note: This heading is used to draw special attention to important points. 1.4 Warranty The manufacturer guarantees the operational safety and reliability of the system only if the following conditions are observed: - Installation, connection, adjustment, maintenance and repairs are carried out only by authorised and qualified specialist personnel. - The pump is not dismantled or handled improperly. - Only original spare parts are used for repairs. The use of other parts results in an exclusion of liability for any resulting damage. - The pump is used in accordance with the instructions in this manual. 5

6 Operating InstructionsGeneral Inappropriate handling and use of acids and lye (storage, refilling, use/application, etc.) in the vicinity of the system invalidates any guarantee or warranty claim. Safety Instructions The safety instructions described in these instructions, existing national regulations on health protection, environmental protection and for accident prevention and any internal working, operating and safety regulations of the operator must be observed. Information that is indicated on the pump itself must be observed. Leakages of dangerous substances must be discharged in such a way that they are not harmful for people and the environment. Damage caused by electrical energy must be prevented, see the regulations of the local electricity supply company. In order to maintain the safe working condition of the pump and ensure a safe operation, the user must follow the instructions and warnings contained in this technical manual. If it must be assumed that a safe operation is no longer possible, the device must be turned off and taken out of service, and made safe against accidental operation. This is the case: - if the pump shows visible evidence of damage, - if the pump is apparently no longer in working order, - after longer periods of storage under unfavourable conditions. Before working on the pump, the pump must be disconnected from the mains. The system must be free of pressure! 1.5 Qualification and training of personnel The personnel responsible for installation, operation and service must be appropriately qualified for these tasks. Roles, responsibilities and supervision of the personnel must be clearly defined by the operator. If necessary, the staff must be appropriately trained. 1.6 Safety of the system in case of failure of the dosage pump Dosage pump design to the latest technical knowledge. Careful manufacturing process. All pumps are tested. If the pump should fail nevertheless, the security of the entire system must be ensured. Use the appropriate monitoring and control functions for this purpose. Ensure that chemicals escaping/leaking from the pump or from damaged pipes cannot cause damage to system components and buildings. It is recommended to install leakage monitors and drip pans. 6

7 Operating InstructionsGeneral 1.7 Dosing of chemicals Caution: Before switching the supply voltage on, the dosing lines must be connected in such a way, so that the chemicals present in the dosing head will not splash out and put people at risk. The dosing medium is under pressure and can cause damage to the health and the environment. Caution: When working with chemicals, the applicable regulations at the place of use are to be applied (e.g. wearing protective clothing). Observe the safety data sheets and safety regulations of the chemicals manufacturer when working with chemicals. Caution: If the diaphragm leaks or is broken, dosing liquid will escape from the discharge opening on the dosing head. Take suitable precautions to prevent harm to health and damage to property caused by escaping dosing liquid! Check daily whether liquid is escaping from the discharge opening! Replacement of the diaphragm, see chapter 7 - Service. A deaeration hose must be connected to the deaeration screw, which is led to a receptacle, such as a drip pan. The dosing medium must be in the liquid aggregate state! Observe the freezing and boiling points of the dosing medium! The resistance of parts, such as dosing head, ball valve, seals and pipes, which come into contact with the dosing medium is dependent on the medium, media temperature and operating pressure. Make sure that the parts that come in contact with the dosing medium are resistent to the dosing medium under operating conditions, see data specifications! For questions regarding the resistance of materials and suitability of the pump for specific dosing media, please contact dinotec. 7

8 Operating InstructionsGeneral description 2 General description The dinodos DDE dosage pump is a self-priming diaphragm pump. It consists of a housing with a stepper motor and electronics, as well as a dosing head with diaphragm and valves. Excellent dosing features of the pump: - Optimal suction performance (even with degassing media), because the pump is always working with full suction stroke volume. - Continuous dosing, since the medium is drawn in with a short suction stroke, regardless of the current dosing flow, and dosed with the longest possible dosing stroke. 2.1 Intended use(s) The pump is suitable for liquid, non-abrasive, non-combustible and non-flammable liquids in accordance with the instructions in these installation and operating instructions. Application areas: - Drinking water treatment - Wastewater treatment - Swimming pool water treatment - Boiler water treatment - CIP (Clean -In-Place) - Cooling water treatment - Process water treatment - Washing plants/installations - Chemical industry - Ultrafiltration processes and reverse osmosis - Irrigation - Paper and pulp industry - Food and beverage industries 2.2 Improper operating methods The operational safety of the pump is only guaranteed if it is used in accordance with section 1.4. Frequent disengagement from the mains voltage, e.g. via a relay, can result in damage to the pump electronics and to the breakdown of the pump. The dosing accuracy is also reduced as a result of internal start-ip processes. Do not use the mains voltage for control of the pump for dosing purposes. Only use the External stop function to start and stop the pump! Caution: Other types of applications or operation of pumps under ambient and operating conditions that are not allowed are considered to be improper and are not permitted. dinotec cannot be held liable for any damage resulting from incorrect use. Caution: The pump is NOT approved for operation in potentially explosive areas! Caution: A sunscreen is required for outdoor installation! 8

9 Operating InstructionsGeneral description 2.3 Device overview Control panel (chapter 6.1) DDE Adjustment knob Keys and status LEDs Mechanical lock Signal inputs (chapter 4.3) Mains connection Valve pressure side Deaeration valve (chapter 5.3) Dosing head Connection deaeration hose Drain hole in case of diaphragm rapture Mounting plate Valve suction side 9

10 Operating InstructionsTechnical data 3 Technical data Mechanical data Pump type DDE 6-10 Pump type DDE 15-4 Setting range [1:X] Max. dosing flow [l/h] Min. dosing flow [l/h] Max. operating pressure [bar] 10 4 Max. stroke frequency [strokes/min] Pump stroke volume [ml] Repeat accuracy [%] ±5 Max. suction lift during operation 1 [m] 6 Max. suction lift when priming with wet valves 1 [m] 2 3 Min. pressure difference between the suction and pressure side [bar] Max. pressure suction side [bar] 2 Max. viscosity with spring-loaded valves 2 [mpas] Max. viscosity without spring-loaded valves 2 [mpas] 50 Min. hose/pipe diameter suction and pressure side [mm] 1,3 4 6 Min. hose/pipe diameter suction side for highly viscous media (HV) 3 [mm] Min. hose/pipe diameter pressure side for highly viscous media (HV) 3 [mm] Max. media temperature [ C] 45 Min. media temperature [ C] -10 Max. ambient temperature [ C] 45 Min. ambient temperature 1 [ C] 0 Max. storage temperature [ C] 70 Min. storage temperature [ C] -20 Max. noise level [db(a)]l Data based on measurements with water 2 Max. suction lift: 1 m, dosing flow reduced (about 30%) 3 Length of suction line: 1.5 m / Length pressure line: 10 m (with max. viscosity) 10

11 Operating InstructionsTechnical data Electrical data Voltage [V] Pump type DDE 6-10 Pump type DDE V, Hz Length connection cable [m] 1.5 Max. current consumption (100 V) [A] 8 Max. current consumption (230 V) [A] 25 Max. power consumption P1 [W] 12 Protection class casing Electrical protection class Signal inputs Max. load empty warning input Max. load pulse input Max. load external stop input Pump type DDE 6-10 IP 65, Nema 4X II 12 V, 5 ma 12 V, 5 ma 12 V, 5 ma Min. pulse length [ms] 5 Max. pulse frequency [Hz] 100 Max. line resistance empty warning [Ω] 1000 Max. line resistance in pulse circuit [Ω] 1000 Weight / Size Pump type DDE 15-4 Pump type DDE 6-10 Weight (PVC, PP, PVDF) [kg] 2.4 Weight (stainless steel) [kg] 3.2 Pump type DDE 15-4 Diaphragm diameter [mm]

12 Operating InstructionsTechnical data 3.1 Dimensions DDE Pump type A1 (mm] B (mm] C (mm] D (mm] DDE DDE

13 Operating InstructionsAssembly and installation 4 Assembly and installation 4.1 Pump assembly The pump is delivered with a mounting plate. The mounting plate can be mounted vertically, e.g. on a wall, or horizontally, e.g. as on a tank. It takes only a few quick steps to firmly secure the pump to the mounting plate by means of a slot mechanism. The pump can easily be released from the mounting plate for maintenance Requirements - The mounting surface must be stable and must not vibrate. - The direction of dosing should be vertically from bottom to top Align the mounting plate and install it. - Vertical installation: The mounting plate slot mechanism must be on top. - Horizontal installation: The mounting plate slot mechanism must be opposite the dosing head. - The mounting plate can be used as a drilling template; for drill hole distances, see above figure. Attaching the mounting plate Caution Take care that no cables or lines are damaged during installation! 1. Mark the drilling holes. 2. Drill the holes. 3. Secure the mounting plate with four screws (5 mm diameter), to the wall, on the mounting bracket, or on the tank Engage pump in mounting plate Attach the pump to the mounting plate support clamps and slide under slight pressure until it engages. 13

14 Operating InstructionsAssembly and installation 4.2 Hydraulic connection Caution: Danger of chemical burns! Wear protective clothing (gloves and safety glasses) while working on dosing head, on connectors or cables! The dosing head may contain water from the factory inspection. When dosing media which should not come into contact with water, another medium must be dosed beforehand! A proper function can only be guaranteed when lines supplied by dinotec are used. The used lines must correspond to the pressure limits specified in chapter 3 "Technical data". Important details regarding the installation - Observe suction lift and cable diameter, see chapter 3 "Technical data". - Shorten the hoses at right angles. - Ensure that there are no loops or kinks in the hoses. - Keep the suction lines as short as possible. - Route suction line up towards the suction valve. - Installing a filter in the suction line protects the entire installation from dirt, thus reducing the risk of leakage. How to connect the hose 1. Slide the union nut and tensioning ring on the hose. 2. Insert the cone part completely into the tube (slide in). 3. Push union nut and tensioning ring across hose. 4. Tighten the union nut by hand. Do not use any tools! When PTFE is used as sealing material, re-tighten the union nut after 2-5 hours of operation! 5. Attach the deaeration hose to the corresponding connection and lead it into a receptacle, such as a drip pan. Union nut Cone part Tensioning ring Hose Note: The pressure differential between the suction and pressure side must be at least 1 bar! Re-tighten the dosing head screws with 3 Nm before commissioning and after 2-5 hours of operation. 14

15 Operating InstructionsAssembly and installation Installation example: The pump offers various installation options. In the example below, the pump is installed in conjunction with a suction lance, level switch and multifunction valve. Deaeration hose Multi-function valve Containe r Suction lance with empty warning 4.3 Electrical connection Connection to the mains Caution: The enclosure class/protection class (IP65) is only guaranteed if plugs or protective caps are correctly installed! Caution: The pump can start automatically when the mains voltage is switched on! Do not manipulate mains plug or cable! The pump is supplied with assembled mains cable and plug. Set capacity adjustment knob to 0 % (see chapter 6.1 "Operating elements"). Connect the mains plug with the mains socket. 15

16 Operating InstructionsAssembly and installation Signal inputs External stop and pulse input Level signal: empty warning Function Pins Type of connection 1/brown 2/white 3/blue 4/black External stop GND X Pulse Pulse GND X Pulse Function Pins Type of connection Empty warning 1/brown 2/white 3/blue 4/black X GND Pulse Note: Use force to push the connectors for signal inputs onto the connection sockets as far as they will go. Otherwise, there is no contact. The union nut cannot push the connector all the way (as far as it will go) into a contact position. 16

17 Operating InstructionsCommissioning 5 Commissioning 5.1 General information Caution: Suction and discharge lines must be connected correctly. The deaeration line must be properly connected and inserted into a suitable tank. Re-tighten the dosing head screws with 3 Nm before commissioning and after 2-5 hours of operation. 5.2 Checks to be carried our before commissioning Check that the rated voltage indicated on the nameplate complies with the local conditions. Check that all connections are assembled correctly. Re-tighten connections, if necessary. Check that the dosing head screws are tightened with the specified torque (3 Nm), retighten if necessary. Check that all electrical cables and plugs are connected correctly. 5.3 Starting and deaerating the pump Connect the mains cable. Open the deaeration screw about half a turn. Press the deaeration key (100 %) and hold it down, until liquid flows out of the deaeration hose continuously and without any bubbles. Close the deaeration screw. The pump is deaerated. 17

18 Operating InstructionsOperation 6 Operation 6.1 Operating elements Logarithmic scale Capacity adjustment knob DDE Status LED "Pulse" Operating mode button Status LED "Manual" Mechanical lock Deaeration button Adjustment knob Use the capacity adjustment knob to set the dosing capacity in percent of the maximum dosing flow of the pump. Due to the logarithmical increase of the percent values, even small dosing capacities can be set accurately. Mechanical lock The mechanical lock protects the set dosing capacity against unauthorised manipulation. For locking, tighten the screw until the adjustment knob cannot be turned anymore. Keys and LEDs When pressing and holding down the deaeration key, the pump doses at 100 % for a certain time. The deaeration key can be used e.g. for deaeration. The operation mode switch is used to change between the Manual and Pulse modes (see chapter.6.2 "Operating modes"). Depending on the current mode, the respective status LED is active ("Pulse" = upper LED; "Manual" = lower LED). The status LEDs indicate the following operating states and faults: LED colour Green (flashing) Green Yellow Red Red (flashing) Operating state/error Stop Running Standby (external stop) Empty warning (alarm) Motor blocked 18

19 Operating InstructionsOperation 6.2 Operating modes The following operating modes are available: Manual, see chapter Pulse, see chapter 6.2.2) Manual In this operation mode, the pump doses constantly the dosing quantity set by the adjustment knob. The setting range is dependent on the pump type: Type Setting range [l/h] DDE DDE Pulse In this operating mode, the pump adds the set dosing quantity for each incoming (potentialfree) pulse, e.g. from a water meter. There is no direct connection between incoming pulses and dosing strokes. The pump automatically calculates the optimum stroke frequency for dosing the set volume per pulse. The calculation is based on: - the frequency of external pulses - the set stroke volume in percent The dosing quantity per pulse is set to a value between 0.1% and 100% of the stroke volume using the adjustment knob. The setting range is dependent on the pump type: Type Setting range [ml/pulse] DDE DDE The frequency of the incoming pulses is multiplied by the set dosing quantity. If the pump receives more pulses than it can process at the maximum dosing flow, it runs at the maximum stroke frequency in continuous operation. Excess pulses will be ignored. Note: To achieve the maximum dosing capacity, we recommend the following setting for dinotec measurement and control devices (also dinotecnet ready and AquaTouch), if they are set to pulse frequency: Type DDE DDE Frequency (pulses/h) at control unit Please observe our operating instructions for your measuring and control device. 19

20 Operating InstructionsOperation Changing the operating mode 1. Set the adjustment knob to 0 %. 2. Connect the mains supply (see chapter 4.3 Electrical connection). 3. Press the operating mode button and hold for at least for 5 seconds. The new operating mode is saved. 6.3 Signal inputs Note: Use force to push the connectors for signal inputs onto the connection sockets as far as they will go. Otherwise, there is no contact. The union nut cannot push the connector all the way (as far as it will go) into a contact position External stop The pump can be stopped via an external pulse, e.g. from a control center. When activating the external stop pulse, the pump switches from the operating condition "Running" to the "Standby" mode. The respective status LED lights yellow according to the selected mode. Frequent disengagement from the mains voltage, e.g. via a relay, can result in damage to the pump electronics and to the breakdown of the pump. The dosing accuracy is also reduced as a result of internal start-ip processes. Do not use the mains voltage for control of the pump for dosing purposes. To start and stop the pump, use only the "External stop" function! Empty warning To monitor the level in the tank, a one-level signal measurement (empty warning) can be connected to the pump. The pump responds to the signal in the following ways: - Active Status LED lights red - Pump stops When the tank is filled up again, the pump restarts automatically! Changing the contact type The signal inputs (empty warning and external stop) are configured at the factory as normally open contact (NO). They can be reconfigured as normally closed contact (NC). The reconfiguration is always made for both inputs. 1. Set the adjustment knob to 0 %. 2. Connect the mains supply 3. (see chapter 4.3 Electrical connection). 4. Press the deaeration button and the operation mode button simultaneously and hold for at least 2 seconds, The new contact type is saved. 20

21 Operating InstructionsService 7 Service In order to ensure a long service life and a proper dosing accuracy, wearing parts such as diaphragms and valves must be regularly checked for signs of wear. Where necessary, replace worn parts with original spare parts made from suitable materials. Should you have any questions, please contact your service partner. 7.1 Service intervals Caution: If the diaphragm leaks or is broken, dosing liquid will escape from the discharge opening on the dosing head. Take suitable precautions to prevent harm to health and damage to property caused by escaping dosing liquid! Check daily whether liquid is escaping from the discharge opening! Interval Daily 2 years or 8000 operating hours Activity Check, if liquid leaks from dosing head, drain opening or valves. If necessary, tighten dosing head screws (3 Nm), valves and union nuts, or perform service (see 7.2 Perform service). Replace diaphragms and valves (see 7.2 Perform service) 7.2 Perform service Only spare parts and accessories from dinotec should be used for maintenance. The usage of non-original spare parts and accessories renders any liability for resulting damages null and void. Caution: Danger of chemical burns! Wear protective clothing (gloves and safety glasses) while working on dosing head, on connectors or cables! Do not allow any chemicals to leak from the pump. Collect and dispose of all chemicals correctly! Before working on the pump, the pump must be disconnected from the mains. The system must be free of pressure! 21

22 Operating InstructionsService Figure pump head: 1 Safety diaphragm 2 Flange 3 O-ring 4 Diaphragm 5 Valve on pressure side 6 Valve on suction side 7 Dosing head 8 Screws with washers 9 Cover 10 Deaeration screw Dismantling the diaphragm and valves 1. Make the system pressureless. 2. Empty the dosing head before maintenance and flush it, if necessary. 3. Set the adjustment knob to 0 %. 4. Switch off mains supply. 5. Take suitable steps to ensure that the returning liquid is safely collected. 6. Dismantle suction, pressure and deaeration hoses. 7. Dismantle valves on suction and discharge side (5, 6). 8. Remove the cover (9). 9. Loosen the screws (8) on the dosing head (7) and remove the screws and discs. 10. Remove the dosing head (7). 11. Unscrew diaphragm (4) counter-clockwise and remove with flange (2) Reassembling the diaphragm and valves 1. Attach the flange (2) correctly and screw on the new diaphragm (4) clockwise. - Make sure that the O-ring (3) is seated correctly! 2. Connect / switch on mains supply. 3. Turn the adjustment knob slowly to bring the diaphragm into its service position inside (end of suction phase, diaphragm retracted). Set the adjustment knob back to 0 %. 4. Switch the mains supply off again. 5. Attach the dosing head (7). 6. Install screws with discs (8) and cross-tighten. Torque: 3 Nm. 7. Attach the cover (9). 8. Install new valves (5, 6). Do not interchange valves and pay attention to direction of arrow. 22

23 Operating InstructionsSpares 9. Connect suction, pressure and deaeration hoses (see section 4.2 Hydraulic connection) 10. Ventilate dosing pump (see section 5.3 Start and vent the pump). 11. Please observe the notes on commissioning in chapter 5 "Commissioning. 7.3 Repair Caution: The pump housing must only be opened by personnel authorised by dinotec. Repairs must only be carried out by authorised and qualified personnel. Switch off the pump and disconnect it from the voltage supply before carrying out maintenance work and repairs. 8 Spares Name Order number Type DDE 6-10 Type DDE 15-4 Diaphragm Suction/pressure valve (PVC version) Suction/pressure valve (version PVDF, chlorineresistent) Pump head * (PVC version) Pump head Fehler! Textmarke nicht definiert. (version PVDF, chlorine-resistent) Hose connector (PVC version) Deaeration screw with O-ring Service kit (PVC version) Service kit (version PVDF, chlorine-resistent)y Frequency cable, connector angled Frequency cable, connector straight Suction lance rigid, adjustable in height, hose length 1.5 m with M12 connector Suction line flexible, with cover screws, hose length 1.5 m with M12 connector Mounting plate incl. 4 screws * Dosing head only available as complete kit with diaphragm, suction/pressure valves and deaeration screw 23

24 Operating InstructionsError 9 Error 9.1 Signalling of faults Depending on the selected operating mode, the pump will signal the following faults/errors via the corresponding status LED: LED colour Error Remedy Re-fill tank Red Empty warning Check type of pulse (see chapter Red (flashing) Motor blocked Reduce the counter pressure If necessary, have the gear repaired 24

25 Operating InstructionsError 9.2 List of errors/faults Error Error cause / Remedy Remedy Dosing flow too high No dosing flow or dosing flow too low Irregular dosing Liquid leaking from the drain opening on the flange Liquid leaking Pump not priming Pump not running (while in the pulse control operating mode) Inlet pressure greater than backpressure Air in dosing head Diaphragm defective Leakage/breakage in lines Valves leaking or clogged Valves not correctly installed Suction line clogged Suction lift too high Viscosity too high Open the deaeration screw Valves leaking or clogged Counter pressure fluctuations Diaphragm defective Dosing head not retightened Valves not re-tightened Suction lift too high Counter pressure too high Control cable plug not inserted properly Install additional springloaded valve (approx. 3 bar) on the discharge side Increase pressure differential Deaerate the pump Replace diaphragm (see 7.2.2) Check the lines and repair Check and clean the valves Check that the arrow on the valve housing is pointing in the direction of flow. Check whether all O-rings have been correctly installed Clean suction line/install a strainer Reduce the suction lift Install a suction aid Use a hose with a larger diameter Install a spring-loaded valve on the pressure side Close the deaeration screw Re-tighten valves, replace valves if necessary (see 7.2.2) Keep the counter pressure at a constant level Replace diaphragm (see 7.2.1) Re-tighten the screws (see 4.2 Connecting the hydraulics) Re-tighten the valves/union nuts (see 4.2 Connecting the hydraulics) Reduce the suction lift, establish a suction feed operation Open the deaeration screw Flush the system, replace valves if necessary (see 7.2) Insert the plug firmly up to the stop 25

26 Operating InstructionsDisposal Error Error cause / Remedy Remedy Pump does not respond to container empty message Pump does not respond to external stop Control cable plug not inserted properly Control cable plug not inserted properly Insert the plug firmly up to the stop Insert the plug firmly up to the stop 10 Disposal This product and all its associated parts must be disposed of in an environmentally friendly manner. Please use the appropriate local waste collection services. If there is no such facility or the facility refuses to accept the materials used in the product, the product can be sent to dinotec. 26

27 Operating InstructionsDisposal 27

28 Simply enjoy the best water! dinotec GmbH Spessartstr. 7, Maintal/Germany Tel. +49 (0) , Fax +49 (0) Internet:

GRUNDFOS INSTRUCTIONS. SMART Digital - DDC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. SMART Digital - DDC. Installation and operating instructions GRUNDFOS INSTRUCTIONS SMART Digital - DDC Installation and operating instructions Declaration of conformity Declaration of conformity GB Declaration of Conformity We, Grundfos Alldos, declare under our

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

GRUNDFOS ALLDOS INSTRUCTIONS. DMB dosing pump. Installation and operating instructions (basic version)

GRUNDFOS ALLDOS INSTRUCTIONS. DMB dosing pump. Installation and operating instructions (basic version) GRUNDFOS ALLDOS INSTRUCTIONS DMB dosing pump Installation and operating instructions (basic version) 1 CONTENTS 1. General information...3 1.1 Applications...3 1.2 Service documentation...3 1.3 Operating

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Dosing Pump Operational Manual

Dosing Pump Operational Manual Chemical Dosing Specialists Dosing Pump Operational Manual Pump Range WMPSP0110 - WMPSP0408 - WMPSP0607 - WMPSP0805 - WMPSP1204 - WMPSP1502 - WMPSP2001 1- Product Introduction 2 1.1 Product Overview 2

More information

Operating Instructions

Operating Instructions Operating Instructions Lubricus Lubrication System LUB - M (24 VDC) Operating Instructions: LUB- M Table of Contents Contents 2 1) General Information 4 1.1 Warning 4 1.2 Scope of supply 4 1.3 Overview

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps GRUNDFOS PRODUCT GUIDE Dosing pumps Contents Features and benefits 3 Performance range 4 Pump selection options 36 Pumped liquids List of pumped liquids 39 Identification Type key 7 Functions Functional

More information

DDA AR-PVC/V/C with access.

DDA AR-PVC/V/C with access. GRUNDFOS DATA BOOKLET DDA 7.5-16 AR-PVC/V/C with access. Grundfos pump 97974077 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/ddafam/97974077/dda-7-5-16-with-access.html

More information

ProMinent Beta Solenoid Diaphragm Metering Pumps

ProMinent Beta Solenoid Diaphragm Metering Pumps Overview: Beta Ideal for basic chemical feed applications (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) ProMinent pk_1_004_1 Capacity range 0.2-8.4 gph, 232-29

More information

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

1. General description CONTENTS. 1.1 Applications. The Buerkert 7800 dosing pump is a self-priming diaphragm

1. General description CONTENTS. 1.1 Applications. The Buerkert 7800 dosing pump is a self-priming diaphragm CONTENTS Page 1. General description 4 1.1 Applications 4 1.2 Type key 5 2. Technical data 6 2.1 Mechanical data 6 2.2 Electrical data 6 2.3 Input/output data 6 2.4 Dimensions 7 3. Installation 7 3.1 Safety

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

DIAPHRAGM LIQUID PUMP NF 1.30

DIAPHRAGM LIQUID PUMP NF 1.30 DIAPHRAGM LIQUID PUMP NF 1.30 NF 1.30 KT DCG 12V Supply voltage [Ch. 4] DCG KT / TT [Ch. 4] 1.30 NF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these Operating

More information

MANUAL. Single charger

MANUAL. Single charger MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Pump Operating and Maintenance Manual - Models

Pump Operating and Maintenance Manual - Models Pump Operating and Maintenance Manual - Models 78-00111 - 78-0057 Thank you for purchasing the SDI Diaphragm Pump manufactured by Comet Pump. Comet produces quality products which are safe, efficient and

More information

RESOL SBS 1000 * * Connection Operation

RESOL SBS 1000 * * Connection Operation RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Instruction Manual. Dosing Pump type /150l/h

Instruction Manual. Dosing Pump type /150l/h Instruction Manual Dosing Pump type 7800 60/150l/h CONTENTS Page 1. General description 4 1.1 Applications 4 1.2 Type key 5 2. Technical data 6 2.1 Mechanical data 6 2.2 Electrical data 6 2.3 Input/output

More information

Micro diaphragm liquid pump NF 25 NFB 25

Micro diaphragm liquid pump NF 25 NFB 25 Micro diaphragm liquid pump NF 25 NFB 25 NF 25 KP DC-M 12V Supply voltage [Ch. 4] DC-M / DC-L / DCB-4 / DCB-4A KP / KT / TT [Ch. 4] 25 NF / NFB - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions

More information

ON SAFEGUARD S ON SAFEGUARD M

ON SAFEGUARD S ON SAFEGUARD M instructions Retrofit option GB ON SAFEGUARD S ON SAFEGUARD M Insulating protective cover Observe additional system documents! General instructions CAUTION Read the operating instructions! The operating

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology ENGLISCH Catalyser 2300-0001 1. Introduction We are pleased with your decision to purchase the Catalyser. Please read the following operating instructions carefully and observe the safety information they

More information

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with diaphragm actuator VZXA-...-M Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids GRUNDFOS alldos product information The digital diaphragm dosing pump for difficult liquids Digital Dosing The Highlights Easy input and display of the dosing rate in l/h or gal/h with perfect calibration

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -450C,-750C, -1300C, -2500C. Service manual

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -450C,-750C, -1300C, -2500C. Service manual Oxiperm C 164 Fully automatic chlorine dioxide processing plant 164-150C, -450C,-750C, -1300C, -2500C Service manual 15.710136-V3.0 1 Imprint Oxiperm C 164 Fully automatic chlorine dioxide processing plant

More information

Micro diaphragm liquid pump NF 1.5 NFB 5

Micro diaphragm liquid pump NF 1.5 NFB 5 Micro diaphragm liquid pump NF 1.5 NFB 5 NF 1.5 KP DC-M 12V Supply voltage [Ch. 4] DC-M / DCB-4 KP / KT / TT [Ch. 4] 1.5 / 5 NF / NFB - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions

More information

DIAPHRAGM PUMPS: Instruction Manual

DIAPHRAGM PUMPS: Instruction Manual INTRODUCTION DIAPHRAGM PUMPS: Instruction Manual Congratulations for choosing a product Imovilli Pompe, the result of a careful manufacturing process supported by over fifty years of specific experience

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

standards based cylinder DNCI Operating instructions e [ ]

standards based cylinder DNCI Operating instructions e [ ] standards based cylinder DNCI en Operating instructions 8072823 2017-05e [8072825] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

OTTO HYDRAULICS GmbH & Co KG SYSTEME UND KOMPONENTEN FÜR ÖLHYDRAULISCHE ANTRIEBE UND STEUERUNGEN SIEMENSSTRASSE 12/ FRIEDRICHSHAFEN

OTTO HYDRAULICS GmbH & Co KG SYSTEME UND KOMPONENTEN FÜR ÖLHYDRAULISCHE ANTRIEBE UND STEUERUNGEN SIEMENSSTRASSE 12/ FRIEDRICHSHAFEN Hydraulik-aggregates Otto-Hydraulics Operating manual Author: Reinhard Otto Date: 16.01.2016 Operating manual rev.1 page: 1/11 Table of Contents Page 1...General information of this operating manual 3

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 050 NPK 0100 Operating and Installation Instructions Read and observe these Operating and Installation Instructions! KNF Neuberger GmbH Alter Weg 3 D-79112

More information

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU The manufacturer declares that: Pfeiffer Chemie-Armaturenbau GmbH, 47906 Kempen, Germany Butterfly valves BR14a, BR14b, BR14b-Type

More information

Diaphragm Metering Pumps

Diaphragm Metering Pumps DATA BOOK DME/DMS, DMM Diaphragm Metering Pumps DME/DMS TECHNICAL DATA BOOKLET 1. General description, DME/DMS, DMM 1.1 Digital Dosing, DME/DMS............ 3 1.2 DMM.............................. 4 1.3

More information

Installation and Operation Manual

Installation and Operation Manual Industrial Process Installation and Operation Manual Advantage Actuator 2.0 Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2 Transportation

More information

DIAPHRAGM LIQUID PUMP NF 1.25

DIAPHRAGM LIQUID PUMP NF 1.25 DIAPHRAGM LIQUID PUMP NF 1.25 NF 1.25 RP DC 12V Supply voltage [Ch. 4] DC / DCB-4A RP / RT [Ch. 4] 1.25 NF / UNF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings FLENDER ZAPEX couplings Type ZWT Operating instructions FLENDER couplings FLENDER ZAPEX couplings Type ZWT Operating instructions Translation of the original operating instructions Technical data Notes

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

Operating instructions ErgoPack 600 E

Operating instructions ErgoPack 600 E Operating instructions ErgoPack 600 E Operation of the device is only permitted if the operating instructions have been carefully read and understood before use! Declaration of conformity EU declaration

More information

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

C3 Operating Instructions

C3 Operating Instructions Version 3.1 Stand 09.2014 Robert Bosch (Australia) Pty. Ltd. 1555 Centre Road Clayton, Victoria 3168 C3 Operating Instructions For further information please contact Bosch at: Australia 1300 30 70 40 www.boschautoparts.com.au

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LB

Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LB Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LB Read the operating instructions! The user is responsible for installation and operation related mistakes! Original Dosing Conveying Control Liquids

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

TBP SERIES PUMPS OPERATION & PARTS MANUAL

TBP SERIES PUMPS OPERATION & PARTS MANUAL TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Voltmaster Centrifugal Trash Pumps

Voltmaster Centrifugal Trash Pumps Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

SCOPELITE TIMING LIGHT OPERATING MANUAL

SCOPELITE TIMING LIGHT OPERATING MANUAL SCOPELITE TIMING LIGHT OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.020-EN Rev. 11/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and

More information

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA 5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page

More information

Primus 221 offers optimum dosing accuracy and operating convenience. The dosing flow variation is only ± 1,5 %

Primus 221 offers optimum dosing accuracy and operating convenience. The dosing flow variation is only ± 1,5 % Product Information Primus 221 The versatile diaphragm dosing pump Primus 221 offers optimum dosing accuracy and operating convenience The dosing flow variation is only ± 1,5 % Primus 221 doses with a

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

Instructions for use and installation Cooker Hood

Instructions for use and installation Cooker Hood Instructions for use and installation Cooker Hood FTU 3807 WXS 70H FTU 3807-P WXS 70H Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...18 CHARACTERISTICS...19 INSTALLATION...20 USE...24 MAINTENANCE...25

More information

Agxcel GX12i Chemical Injection System

Agxcel GX12i Chemical Injection System Agxcel GX12i Chemical Injection System Table of Contents System Contents... 3 Specifications... 4 Safety Precautions and Tips... 5 Operations... 6 Installation... 7 Maintenance... 8-9 Troubleshooting...

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2-way angle seat control valve 2/2-Wege-Schrägsitzregelventil Vanne de réglage à siège incliné 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical

More information

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability Diaphragm interposed fluid head Use and maintenance manual Model Model BR Model UK Positive displacement metering pump PDP Series Type B I 250 I 350 SD GENERAL WARNING General instructions We thank you

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

ProMinent delta Solenoid Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps Overview: delta Ideal for applications requiring metering pump accuracy with minimal pulsation (see page 127 for spare parts and page 134 for control cables) Continuous or pulsating dosing Configurable

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps Overview: gamma/ L Ideal for applications requiring automation, large turndown and/or feed verification (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) Capacity

More information

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product 77014 / 65041 Submersible Water Pumps Automatic Users Manual Carefully read this entire Instruction Manual before using this product Please read these operating instructions carefully and ensure they are

More information

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS SAINT-GOBAIN PERFORMANCE PLASTICS FRANCE SAINT-GOBAIN PERFORMANCE PLASTICS EADAC DES BERTHILLIERS 7301 Orangewood Avenue F-71850 CHARNAY

More information

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP ProMinent Modular design allows selection of the features you need Three diaphragm sizes

More information

Operating instructions Diaphragm Metering Pump Makro TZ, TZMb

Operating instructions Diaphragm Metering Pump Makro TZ, TZMb Operating instructions Diaphragm Metering Pump Makro TZ, TZMb P_MA_0022_SW Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any damage caused

More information

GRUNDFOS DATA BOOKLET. SMART Digital DDA, DDC, DDE. DIGITAL DOSING pumps and accessories

GRUNDFOS DATA BOOKLET. SMART Digital DDA, DDC, DDE. DIGITAL DOSING pumps and accessories GRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories SMART Digital Table of contents. General data Performance range Features at a glance 4. Identification 6 Type key

More information

Inhalt. Granule jet blasting device PG 5 8. Owner s Manual. Translation of the original instructions

Inhalt. Granule jet blasting device PG 5 8. Owner s Manual. Translation of the original instructions Inhalt Granule jet blasting device PG 5 8 Owner s Manual Translation of the original instructions 1 This instruction manual is protected by copyright. No use outwith the strict limitations of copyright

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Globe control valve, pneumatically operated Actuator sizes 40 mm - 125 mm, Nominal diameter DN10-65 Kolbengesteuertes Geradsitzventil Antriebsgrößen 40 mm - 125 mm, Nennweiten DN10-65 Vanne à siège droit

More information

Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4

Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4 Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4 Two sets of operating instructions are required for the safe, correct and proper operation of the ProMinent Hydro metering pumps: These

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072

BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072 BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are reserved

More information

Precision-24 Manual & Specification

Precision-24 Manual & Specification Precision-24 Manual & Specification 1 Product Introduction... - 1-1.1 Product Overview... - 1-1.2 Technical Parameter...- 2-1.2.1 General Parameter...- 2-1.2.2 Performance Parameter... - 3-1.2.3 Installation

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP 03 KP DC-B1 NMP 03 KP DC-S NMP 03 KP DC-B3 NMP 03 KP DC-M NMP 03 KP DC-L You have selected a high-quality KNF

More information

Medo GA, GC, GE Product Data Sheet POE_CT0401. Dosing Pumps.

Medo GA, GC, GE Product Data Sheet POE_CT0401. Dosing Pumps. Medo GA, GC, GE Dosing Pumps Product Data Sheet -53437 POE_CT040 Up-to-date version as of January 08 Replaces all older versions Reference manual no.: -50359-5036 -50363 www.bwt.de Thank you very much

More information

GRUNDFOS DATA BOOKLET. SMART Digital DDA, DDC, DDE DIGITAL DOSING. pumps and accessories

GRUNDFOS DATA BOOKLET. SMART Digital DDA, DDC, DDE DIGITAL DOSING. pumps and accessories GRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories SMART Digital Contents. General data 3 Performance range 3 Features at a glance 4. Identification 6 Type key 6 3.

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information