C owners manual WHEN ACCURACY IS THE POINT.

Size: px
Start display at page:

Download "C owners manual WHEN ACCURACY IS THE POINT."

Transcription

1 C-2000 owners manual TM WHEN ACCURACY IS THE POINT.

2 TABLE OF CONTENTS 2 C-2000 Features 3 Button Functions 3 Check Calibration 4 Set the Scale 4 To Change the Set-Point 5 Information About Your Readings 5 To Check the Accumulated Readings 6 To Reset Meter 6 Applications 9 Temperature Correction 9 Care Of Your Meter 10 Service for Your Meter 11 Warranty

3 DELMHORST C-2000! Read Calibration Check Button # Set-Point Button $ Scale Button C-2000 FEATURES hdesigned to check the moisture content in lint cotton and seed hresistance technology recognized around the world as the most accurate method for measuring moisture. h Averages up to 100 accumulated readings h 4% 16% moisture range on lint cotton h 6% 20% moisture range on seed cotton h Digital readout h Includes (1) 9-volt battery h Proven microcontroller circuit h One-year warranty h 60 years of proven quality, accuracy and service 2

4 BUTTON FUNCTIONS! Read: Reads the %MC Check: Checks the meter calibration. Displays the average of up to 100 accumulated readings; displays the highest stored reading; erases the readings from memory. # Set-Point: Displays the current set-point. Also acts as an arrow (scroll) key to increase the set-point value in 1% increments. A buzzer will alert you if the meter reads higher than the selected %MC value. $ Scale: Displays the meter scale as #1 (Lint) or #2 (Seed) cotton and acts as a toggle to change between the two scales. Also acts as an arrow key to decrease the set-point value. CHECK CALIBRATION hpress the calibration check and read button! simultaneously. Meter is in calibration if it displays 11.1%, ±.2, regardless of the scale setting. When checking calibration, there is no need to disconnect the external electrode. If you check the calibration and the display does not read 11.1, it is likely an indication of a low battery. If this occurs, change the battery immediately. Continued use with a low battery may cause the meter to go out of calibration.if you have a fresh battery and the instrument still does not indicate an acceptable calibration, return it to DELMHORST for service. See Service for Your Meter section. When the battery is replaced, the meter displays its software version for one second and then turns itself off. After replacing the battery, you must reset the meter as described in the Resetting the Meter section. 3

5 TO SET THE SCALE Set the scale for #1 Lint Cotton or # 2 Seed Cotton. hto change the scale, press the scale button $. The meter will display the current scale for one second. hpress and hold the scale button $ to toggle between the two scales. hrelease the scale key $ to stop at the desired scale. Changing the scale will automatically reset the set-point value to the default setting for that particular scale. Default settings are as follows: Lint Cotton 7% Seed Cotton 12% TO CHANGE THE SET-POINT hto change the set-point value press the set-point button #. The meter will display the current set-point value for the scale you have chosen for one second. hto scroll forward to a higher value for that scale hold the set-point button # while the current set-point is displayed and scroll to the set-point value desired. hto scroll backward through the set-point values, press and release the set-point button #. Within one second, press and hold the scale button $. Continue to hold the scale button $ and the set-point will decrease. hwhen scrolling in either direction, release the button to stop at your desired set-point. ha buzzer sounds if the meter reads a %MC higher than the set-point. 4

6 INFORMATION ABOUT YOUR READINGS The meter will accumulate up to 100 readings. After all 100 readings are stored it will not add new readings until the memory has been cleared. It will also continue to display the average of all 100 readings as a reminder that the memory is full. hto add a reading to the sum of all the previously stored readings, release the read button! within 2 seconds. When taking and storing readings for a specific material, be sure to clear the meter before moving on to the next scale if you do not want to group all of the readings together. Moisture content of the samples is the primary factor affecting meter readings. However, readings are also affected by the following: htype of cotton harea where it is grown himpurities hcompaction (density) around the electrode surfaces htemperature of the sample In order to minimize the effect of these factors and improve the repeatability of the meter readings, keep in mind the following points: huse samples with minimum of impurities. hoptimal accuracy may be obtained if meter readings are checked against %MC by means of properly run oven tests on the particular product being tested. TO CHECK THE ACCUMULATED READINGS This feature displays the total number of all accumulated readings for the given material you have chosen, the average of those readings, and the highest stored reading. hto view the readings, press and release the calibration check First the meter displays the number of accumulated readings for one second, then the average of those readings for two seconds. Then it displays the highest stored reading for two seconds. The total cycle time is five seconds. 5

7 hto keep the accumulated readings in memory release the calibration check before the total cycle time is complete. hto erase readings, hold the calibration check for more than five seconds. The total, average and highest readings will be displayed as above, followed by a zero to indicate all readings have been erased. TO RESET METER hpress and release the calibration check hwithin one second, press and hold the scale The meter will display a reset sequence as follows: 121, 8, 1.1, The last number, 11.1 is a calibration check. hresetting the meter clears the memory and restores default settings. APPLICATIONS Testing Lint Cotton hattach the #52-E/C Sample Cup Electrode to the connector on top of the meter. hset the scale for (#1) Lint Cotton and select a set point. hplace a small quantity of cotton in the sample cup. Press the cotton firmly into the cup with your finger. The cotton sample in the cup should be overflowing during the test, even while you are pressing it with your finger. hpress the read button! and read the moisture content on the display. The meter displays the %MC for two seconds. Readings below 4% lint cotton will be displayed as a negative number. Readings above 16% lint will be displayed as a blinking 16.2%. Both the underrange and overrange readings should be disregarded. They will not be added to the accumulated readings or used in calculation of the average or highest reading. 6

8 Testing Seed Cotton hattach the #52-E/C Sample Cup Electrode to the connector on top of the meter. hset the scale for (#2) Seed Cotton and select a set point. hplace a small quantity of cotton in the sample cup. Press the cotton firmly into the cup with your finger. The cotton sample in the cup should be overflowing during the test, even while you are pressing it with your finger. hpress the read button! and read the moisture content on the display. The meter displays the %MC for two seconds. Readings below 6% seed cotton will be displayed as a negative number. Readings above 20% seed cotton will be displayed as a blinking 20.2%. Both the extreme low and extreme high readings should be disregarded. They will not be added to the accumulated readings or used in calculation of the average or highest reading. Tests made on seed cotton may not be as accurate as those made on lint cotton. This is due to the fact that the seed cotton sample is obviously made up of lint and seed, and the quantity of seed may vary from sample to sample. Also, the moisture content of the seed is usually higher than that of the lint. When testing seed cotton, direct contact is still made with the cotton fiber only and not with the seed of the sample. Variables in quantities and moisture content of the seed, during calibration and in field tests, may affect the accuracy and repeatability of the meter readings. The seed cotton scale gives an indication of total moisture content (the moisture content of the seed and the lint in a sample as determined by oven tests) in the seed cotton sample. This may be of interest only in buying and selling seed cotton where some consideration may be given to the weight relationship between moisture content and dry matter. 7

9 Testing Baled Cotton hslide the plastic spacer over the #491 contact pins from the bottom of the pins, mount the pins in the chucks and tighten the set screws. (The #491 contact pins are not inserted into the chucks for shipping purposes). hattach the #30-E/C Electrode to the connector on top of the meter. hset the Scale to #1 Lint Cotton and select a set point. hinsert the electrode pins into the bale and press the read button!. hplace the pin spacers near the tips of the pins when contact is first made with the bale. This helps to keep the pins parallel as they are forced into the bale. The #491 contact pins are insulated, except for 1-3/4 at the tip. The insulation helps to identify the area of moisture, since the reading is obtained from the tip of the pin. Keeping track of moisture readings as the pins are pushed into the bale will give an idea of the uniformity of moisture distribution in the bale. Higher moisture readings near the surface are an indication that the cotton has been exposed to higher moisture after baling. The C-2000 gives accurate results on normally compressed bales. If the bale is loosely packed, the meter will read lower than the actual moisture content. If the bale is very tightly packed, the readings will be only slightly higher than normal, and as a rule, no correction needs to be made. Well-conditioned material will give uniform readings; however, material that is baled before it is dry will show a wide range of moisture content. Several tests should be made on each bale, and you should note the average and the highest readings of these tests. Testing Yarn hconnect the #37-E/C multi-pin electrode to the connector on top of the meter. hset the scale to #1 lint cotton and select a set point. hinsert the electrode pins into the yarn and press the read button!. 8

10 Temperature Correction The basic calibration assumes the cotton temperature to be 70 F. For best accuracy, apply a temperature correction if the cotton temperature is outside the range of 60 F to 80 F. Make a correction of approximately 1.0% for every 20 F. The meter will read higher than the actual moisture content as cotton temperature increases, and will read lower as cotton temperature decreases. Example: At 70 F, a reading of 7% indicates actual %MC of 7%. At varied temperatures, meter readings will vary as follows: Cotton Temperature Meter Reading Actual %MC 110 F 9.0% 7% 50 F 6.0% 7% CARE OF YOUR METER To keep your meter in good working order: hstore your meter in a clean, dry place. The protective carrying case provided is an ideal storage place when the meter is not in use. hchange the 9-Volt battery as needed. Continued use with a low battery may cause the meter to go out of calibration. hclean the meter, contact pins, and probes with any biodegradable cleaner. Use the cleaner sparingly and on external parts only. Keep the cleaner out of the external connector. DO NOT IMMERSE THE METER OR ANY ELEC- TRODE IN WATER. hremove the battery if the meter will not be used for one month or longer. 9

11 SERVICE FOR YOUR METER hbefore sending in your meter we recommend you give one of our trained technicians a call. Many times troubleshooting can be taken care of over the phone. Call us at 877-DELMHORST. hpack your meter securely. Enclose a purchase order or letter with a brief description of the problem. hthere is no need to call us for a return authorization number if you are within the U.S. Customers outside the U.S. must contact us for more specific instructions prior to returning a meter. hinclude your name, address, daytime phone and fax numbers or address. If you believe the meter is under warranty, please provide the original sales slip or invoice. hship via UPS, Express Mail, Priority Mail or any overnight courier who provides prompt service. Do not use standard parcel post. hinsure your instrument for its full value and ship prepaid. We are not responsible for damage in transit. hwe do not accept COD shipments or cover any incoming freight or duty charges on returned merchandise hturnaround time on repairs is approximately two weeks. hwe will call you with an estimate if you specifically request one, or if we determine that the meter may be too costly to repair. hnon-warranty repairs will be returned via UPS/COD unless you have already established other payment terms. There is no COD service outside the U.S. To pay by credit card, include the card number and expiration date with your repair. We accept Visa/MasterCard and American Express. hwarranty repairs will be returned at no charge if shipped within the U.S. via UPS Ground Service. Freight charges for expedited services (i.e., Federal Express, UPS/2 Day, UPS/1 Day, etc.) are the customer s responsibility and will be charged as per the above terms. 10

12 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its C-2000 meter for one year from date of purchase and any optional electrodes against defects in material or workmanship for 90 days. If, within the warranty period of the C-2000, you find any defect in material or workmanship return the meter following the instructions in the Service for Your Meter section. This limited warranty does not cover abuse, alteration, misuse, damage during shipment, improper service, unauthorized or unreasonable use of the meter or electrodes. This warranty does not cover batteries, pin assemblies, or pins. If the meter or any optional electrodes have been tampered with, the warranty shall be void. At our option we may replace or repair the meter. Delmhorst shall not be liable for incidental or consequential damages for the breach of any express or implied warranty with respect to this product or its calibration. With proper care and maintenance the meter should stay in calibration; follow the instructions in the Care of Your Meter section. Under no circumstances shall Delmhorst be liable for any incidental, indirect, special, or consequential damages of any type whatsoever, including, but not limited to, lost profits or downtime arising out of or related in any respect to its meters or electrodes and no other warranty, written, oral or implied applies. Delmhorst shall in no event be liable for any breach of warranty or defect in this product that exceeds the amount of purchase of this product. The express warranty set forth above constitutes the entire warranty with respect to Delmhorst meters and electrodes and no other warranty, written, oral, or implied applies. This warranty is personal to the customer purchasing the product and is not transferable. 11

o w n e r s m a n u a l

o w n e r s m a n u a l P-2000 o w n e r s m a n u a l TM W H E N A C C U R A C Y I S T H E P O I N T. TABLE OF CONTENTS 2 P-2000 Features 3 Key Functions 3 Check Calibration 4 To Set the Scale 4 To Change the Set-Point 5 Information

More information

HT owners manual WHEN ACCURACY IS THE POINT.

HT owners manual WHEN ACCURACY IS THE POINT. HT-3000 owners manual TM WHEN ACCURACY IS THE POINT. TABLE OF CONTENTS 3 Introduction 3 Operation 4 Auto-Off 4 Backlight 4 Low Battery 4 Adjusting the Display Contrast 5 Operation Summary 5 Calibration

More information

F-2000 owners manualb&w_f-2000 owners manual out 1/11/13 11:31 AM Page 1 F owner s manual WHEN ACCURACY IS THE POINT

F-2000 owners manualb&w_f-2000 owners manual out 1/11/13 11:31 AM Page 1 F owner s manual WHEN ACCURACY IS THE POINT F-2000 owners manualb&w_f-2000 owners manual out 1/11/13 11:31 AM Page 1 F-2000 owner s manual. WHEN ACCURACY IS THE POINT TM F-2000 owners manualb&w_f-2000 owners manual out 1/11/13 11:31 AM Page 2 F-2000

More information

J owners manual WHEN ACCURACY IS THE POINT.

J owners manual WHEN ACCURACY IS THE POINT. J-2000 owners manual TM WHEN ACCURACY IS THE POINT. TABLE OF CONTENTS 2 J-2000 Features 3 Before You Begin 3 Check Calibration 4 Set Species 5 Species Code Chart 6 Set Temperature 7 Set Pin Calibration

More information

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer Owners Manual TABLE OF CONTENTS 3 INTRODUCTION 3 OPERATION 3 AUTO-OFF 3 BACKLIGHT 4 LOW BATTERY 4 ADJUSTING THE DISPLAY CONTRAST 4 OPERATION SUMMARY

More information

G-34 HOPS MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS

G-34 HOPS MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS G-34 HOPS MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS info@delmhorst.eu www.moisturemetersdelmhorst.com +31 (0)73 6395080 1 G-34 TABLE OF

More information

FX-2000 HAY MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS

FX-2000 HAY MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS FX-2000 HAY MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS info@delmhorst.eu www.moisturemetersdelmhorst.com +31 (0)73 6395080 TABLE OF CONTENTS

More information

J-Lite. o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T

J-Lite. o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T For 65 years Delmhorst Instrument has been the leading manufacturer of high quality, US-made moisture meters and thermo-hygrometers. Today we offer a wide range of meters for applications including water

More information

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview

More information

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

ODY-05-2 VOLTMETER FOR REMOTE MONITORING ODY-05-2 VOLTMETER FOR REMOTE MONITORING Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features

More information

Phase Sequence Tester

Phase Sequence Tester User's Guide Phase Sequence Tester Model 8000 Introduction Congratulations on your purchase of the Extech Model 0800 Phase Sequence Tester. This handheld instrument detects the phase sequence of three-phase

More information

ODY-17-1 DIGITAL COMPASS DISPLAY

ODY-17-1 DIGITAL COMPASS DISPLAY ODY-17-1 DIGITAL COMPASS DISPLAY Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and

More information

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter Model FMBC3000 Series Operating Instructions Drum Pump Flow Meter Table of Contents Safety... 1 Introduction... 1 Specificatons... 1 Features... 1 Section 1 - Installation... 2 Section 2 - Operation...

More information

ODY-19-1 AIR PRESSURE GAUGE

ODY-19-1 AIR PRESSURE GAUGE ODY-19-1 AIR PRESSURE GAUGE Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and easy

More information

HLY-1111 HEAD TEMPERATURE GAUGE

HLY-1111 HEAD TEMPERATURE GAUGE HLY-1111 HEAD TEMPERATURE GAUGE Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and

More information

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M Operators Manual BHT-2 Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M0160 07-10 Introduction THANK YOU for purchasing the BHT-2, Advanced Baler-Mounted Hay Moisture Tester. READ THIS MANUAL

More information

GARNET. SEE Tester II TM INSTRUMENTS LTD. Model 900M Manual PRINTED IN CANADA

GARNET. SEE Tester II TM INSTRUMENTS LTD. Model 900M Manual PRINTED IN CANADA GARNET INSTRUMENTS LTD. SEE EELEVE EVEL II Tester II TM Model 900M Manual PRINTED IN CANADA GARNET INSTRUMENTS LTD. L II TM SEE EELEVE EVEL II Tester Model 900M Manual TABLE OF CONTENTS 1) OVERVIEW and

More information

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M Operators Manual BHT-2 Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M0160 07-10 Introduction THANK YOU for purchasing the BHT-2, Advanced Baler-Mounted Hay Moisture Tester. READ THIS MANUAL

More information

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M Operators Manual BHT-2 Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M0160 07-10 Introduction THANK YOU for purchasing the BHT-2, Advanced Baler-Mounted Hay Moisture Tester. READ THIS MANUAL

More information

ADI-125/750 ADI-125/1500 ADI-125/2500

ADI-125/750 ADI-125/1500 ADI-125/2500 Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS

More information

ODY-10-1 rev. B FUEL PRESSURE GAUGE

ODY-10-1 rev. B FUEL PRESSURE GAUGE ODY-10-1 rev. B FUEL PRESSURE GAUGE Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features

More information

II DISTRIBUTION & SUBSTATION TYPE C

II DISTRIBUTION & SUBSTATION TYPE C CapCheckIII DISTRIBUTION & SUBSTATION TYPE Ca p a c i t o r C h e c ke r Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e

More information

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation Interior Digital Load Scale 202-DDG-01 Installation and Operation Manual Please read carefully before installation Contents Specifications:... 2 1.0 Installation and Set-up Overview... 3 2.0 Gauge Installation

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation Interior Digital Load Scale 202-DDG-02 Installation and Operation Manual Please read carefully before installation Contents Specifications:... 2 1.0 Installation and Set-up Overview... 3 2.0 Gauge Installation

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR) TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for

More information

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs Model AS-RC3260 TV Cart Rolling Cart for Audio Mount System & Flat Panel TVs GETTING STARTED Introduction Congratulations on the purchase of your new Helios AS-RC3260 Rolling Cart. For maximum benefit,

More information

Model GX Spray Gun

Model GX Spray Gun "Teamwork & Communication" Model GX-7-400 Spray Gun Parts Identification Manual 17943-ID May 24, 1999 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood,

More information

Tracer ORP PockeTester TM Code 1742

Tracer ORP PockeTester TM Code 1742 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Tracer ORP PockeTester TM Code 1742 Water Testing Leader Since 1919! TRACER ORP

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified

More information

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS

More information

ECLIPSE Laundry Dispenser Controller

ECLIPSE Laundry Dispenser Controller ECLIPSE Laundry Dispenser Controller Reference Manual Programming and Operation Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online

More information

Mechanical Spiral Sensor

Mechanical Spiral Sensor Installation Manual Model 6005-1 Mechanical Spiral Sensor No part of this instruction manual may be reproduced, by any means, without the written consent of Geokon, Inc. The information contained herein

More information

TABLE OF CONTENTS 10.0 LIMITED WARRANTY

TABLE OF CONTENTS 10.0 LIMITED WARRANTY 10.0 LIMITED WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions

More information

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit 10552 The following instructions are intended for professional installers. Speedtech Performance assumes NO responsibility for the installation

More information

MoistureMatch A next generation grain tester

MoistureMatch A next generation grain tester MoistureMatch A next generation grain tester A next generation moisture tester incorporating new and unique technology. Finally, a portable tester that will more accurately match and track with the commercial

More information

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual Manual HanTron Model HT-3P Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL JANUARY

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

Model D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION

Model D Spray Gun. Parts Identification Manual 2943J-ID. Success through Unity June 17, 2003 Issue 2 GUSMER CORPORATION "Success through Unity" Model D Spray Gun Parts Identification Manual 2943J-ID June 17, 2003 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood, New Jersey,

More information

P/N X-SERIES GAUGE VOLTAGE 8 TO 18V

P/N X-SERIES GAUGE VOLTAGE 8 TO 18V Instruction Manual P/N 30-0303 X-SERIES GAUGE VOLTAGE 8 TO 8V STOP! - READ THIS BEFORE INSTALL OR USE! WARNING: THIS INSTALLATION REQUIRES WELDING AND INTEGRATION INTO A VEHICLE'S ELECTRICAL SYSTEM. DAMAGE

More information

INSTALLATION/OWNERS MANUAL

INSTALLATION/OWNERS MANUAL INSTALLATION/OWNERS MANUAL XOBP12D PREPARATION Getting Started Thank you for purchasing the Dual Electronics XOBP12D Bandpass Subwoofer System. Although Dual has attempted to make sure all of the information

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT LOAD CAPACITY: 500 LBS [227 kg] MANDATORY: LEAVE THIS MANUAL WITH LIFT OWNER WARNING 1. READ AND FOLLOW ALL INSTRUCTIONS. LIFT SAFETY

More information

Temperature Programming Quick Reference Guide

Temperature Programming Quick Reference Guide Temperature Programming Quick Reference Guide Normal Mode Dial Brightness (press one at a time) Peak Mode Factory Default Reset (Hold for 5 seconds) High Alert Setting Mode Use LEFT or RIGHT buttons to

More information

MIL-24/2600Q MIL-24/3200DQ

MIL-24/2600Q MIL-24/3200DQ Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121473B OWNER'S

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS

More information

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation Interior Digital Load Scale 202-DDG-01 Installation and Operation Manual Please read carefully before installation Specifications: Operating Temperature: -20 C to +85 C (-4 F to +185 F) Storage Temperature:

More information

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Model T2642 Wall Mount. Television Wall Mount with Tilt Option Model T2642 Wall Mount Television Wall Mount with Tilt Option Getting Started Introduction Congratulations on the purchase of your new Audio Solutions T2642 Television Wall Mount. For maximum benefit,

More information

INW Panel Meter Reading an INW PT12 Sensor

INW Panel Meter Reading an INW PT12 Sensor INW Panel Meter Reading an INW PT12 Sensor PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company Table of Contents Introduction...5 What is an INW Panel Meter for an INW PT12 Smart Sensor?...5 Initial

More information

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK. Flow Chart Programming Instructions for : VOLTMETER 2 1/16 Program Main Menu (Press one button at a time) START HERE Main Menu ONE NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness.

More information

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS

More information

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9 Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual Current for Software Version 6.9 About This Manual This manual could contain technical inaccuracies or typographical errors.

More information

NEXUS. Introduction SENSOR MODULE &

NEXUS. Introduction SENSOR MODULE & 2650-1056 INSTALLA AT TION INSTRUCTIONS NEXUS SENSOR MODULE & REMOTE ASSEMBLY IMPORTANT WEAR SAFETY GLASSES 60 80 40 100 FUEL 20 PSI 0 AUTO METER PRODUCTS INC. c 2004-6463 0 10 20 10 20 BOOST VAC In.Hg

More information

INSTRUCTIONS TUBULAR CONTROL ARMS & COIL-OVER CONVERSION FOR AMC MUSCLE CARS: 1970 AMX JAVELIN SPIRIT, HORNET, GREMLIN, CONCORD

INSTRUCTIONS TUBULAR CONTROL ARMS & COIL-OVER CONVERSION FOR AMC MUSCLE CARS: 1970 AMX JAVELIN SPIRIT, HORNET, GREMLIN, CONCORD AMC TUBULAR CONTROL ARMS & COIL OVER KIT INSTRUCTIONS TUBULAR CONTROL ARMS & COIL-OVER CONVERSION FOR AMC MUSCLE CARS: 1970 AMX 1970-74 JAVELIN SPIRIT, HORNET, GREMLIN, CONCORD Revised 6/1/2012 www.freakride.com

More information

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE This user s manual contains important information about your ValveSentry device s operation. If you are installing this

More information

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS.   Version 1.2 AUTO-BLiP INTELLIGENT DOWNSHIFTS www.auto-blip.com User Manual 2005+ Porsche Version 1.2 Copyright 2012 Tractive Technology, LLC. All rights reserved. Page 1 WARNING Use of the AUTO-BLiP while driving

More information

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems The Fresh-Aire UV Airborne Duct System is designed for installation into commercial HVAC system ducts for

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

AUTO-BLiP.   User Manual Chevrolet Corvette. Version 1.7 AUTO-BLiP INTELLIGENT DOWNSHIFTS www.auto-blip.com User Manual 2008-2013 Chevrolet Corvette Version 1.7 Copyright 2012 Tractive Technology, LLC. All rights reserved. Page 1 WARNING Use of the AUTO-BLiP

More information

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount Model AS-FM64 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions AS-FM64 Television Wall Mount. For maximum benefit, please

More information

BP1204 INSTALLATION/OWNER'S MANUAL

BP1204 INSTALLATION/OWNER'S MANUAL BP1204 INSTALLATION/OWNER'S MANUAL BP1204 PREPARATION Getting Started Thank you for purchasing the Dual Electronics BP1204 Bandpass Subwoofer System. Although Dual has attempted to ensure the information

More information

TMD90A Dual Input Digital Thermometer

TMD90A Dual Input Digital Thermometer TMD90A Dual Input Digital Thermometer User Manual For detailed specifications and ordering info go to www.testequipmentdepot.com TMD90A Dual Input Thermometer Contents Safety Information 2 Symbols Used

More information

2015 & 2018 Fender Brace Installation Instructions

2015 & 2018 Fender Brace Installation Instructions 2015 & 2018 Fender Brace Installation Instructions Thank you for your purchase of this Hotchkis Performance product. Your Fender Brace set was designed with the performance and durability you ve come to

More information

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS

More information

Airpax Dimensions, Inc.

Airpax Dimensions, Inc. Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 121177B OWNERS MANUAL JANUARY 2007 Airpax Dimensions, Inc. Uninterruptible Power System OWNERS

More information

5 Grinder-Vac and Shroud Kit Operating Manual

5 Grinder-Vac and Shroud Kit Operating Manual 5 Grinder-Vac and Shroud Kit Operating Manual Introduction The Grinder-Vac is designed for simple operation and has been proven to be extremely useful and versatile. A 4.5 diamond cup wheel or zec style

More information

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com CM100 Carbon Monoxide Meter Users Manual CM100 Carbon Monoxide Meter English Users

More information

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Model FM2642 Wall Mount. Full Motion Television Wall Mount Model FM2642 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions FM2642 Television Wall Mount. For maximum benefit, please

More information

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User Guide. Model Insulation Tester / Megohmmeter. Introduction User Guide Model 380363 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity

More information

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Cardinal DETECTO PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual CARDINAL SCALE MFG. CO. PO BOX 151, WEBB CITY, MO 64870 0066-M176-O1 Rev H 10/06 417-673-4631 www.cardinalscale.com Printed

More information

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS.  Version 1.2 AUTO-BLiP INTELLIGENT DOWNSHIFTS www.auto-blip.com User Manual 2015-2016 Ford Mustang Version 1.2 Copyright 2012 Tractive Technology, LLC. All rights reserved. Page 1 WARNING Use of the AUTO-BLiP while

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

Model P772 Conductivity Meter. User Manual

Model P772 Conductivity Meter. User Manual Model P772 Conductivity Meter User Manual 1 Table of Contents 1 INTRODUCTION... 1 2 SAFETY SUMMARY... 2 3 COMPLIANCE STATEMENTS... 2 4 PRODUCT CONTENTS AND INSPECTION... 3 5 DEVICE DESCRIPTION... 4 6 OPERATING

More information

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02 OI-001 NOTES TABLE OF CONTENTS 1.0 Operating principle.............................................. 02 2.0 Overview....................................................... 03 2.1 Operating elements 2.2

More information

HIGH VOLTAGE DIGITAL AMMETER

HIGH VOLTAGE DIGITAL AMMETER HIGH VOLTAGE DIGITAL AMMETER Operating & Instruction Manual HVA-2000 Making the Invisible Visible TM 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e b s

More information

ODYR-19-5 & SLX-19-5 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

ODYR-19-5 & SLX-19-5 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE ODYR-19-5 & SLX-19-5 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE Features: All bag pressure readings displayed at once on a 2-line display. Optional storage tank pressure readout. A warning feature that flashes

More information

SOLAR DASH CHARGING SYSTEM USER GUIDE

SOLAR DASH CHARGING SYSTEM USER GUIDE SOLAR DASH CHARGING SYSTEM Doc 1.01 INST049 INSTALLATION STEP 1 Place 20 watt solar panel in the dash of the vehicle facing up. Note: For ideal results position the vehicle in a manner in which the solar

More information

ODY-01-1 or ODY-01-2 SPEEDOMETER

ODY-01-1 or ODY-01-2 SPEEDOMETER ODY-01-1 or ODY-01-2 SPEEDOMETER Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and

More information

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide Flo-Way R Solids Impact Flow Meter Measure Granular or Powdered Material Stand Alone or Connect to Other Devices for Blending Used by Successful Producers World-Wide Visit our website: www.beltwayscales.com

More information

User s Manual. Item no. 2561

User s Manual. Item no. 2561 User s Manual Item no. 2561 Solar e Charger Exec Duo by Wagan Tech User s Manual Read before using this equipment Mini USB Port Power switch Charging jack Basic Operation 1. Insert and attach the iphone

More information

User Manual. Posture+ Adjustable Base. For customer service call:

User Manual. Posture+ Adjustable Base. For customer service call: User Manual Posture+ Adjustable Base For customer service call: 1-877-707-7533 1 IMPORTANT INFORMATION PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE USING THIS PRODUCT. PROPER OPERATION OF YOUR ADJUSTABLE

More information

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. LSF Start-Up Instructions 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. 2) PRE-START-UP: Be sure there is water in the pump. Bleed air at all high points

More information

Right Weigh. Load Scales. Right Weigh Digital Load Scale. Model 201-EDG-01(B) Installation and Operation Manual

Right Weigh. Load Scales. Right Weigh Digital Load Scale. Model 201-EDG-01(B) Installation and Operation Manual Right Weigh Load Scales Right Weigh Digital Load Scale Model 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation Right Weigh Load Scales Table of Contents Model 201-EDG-01

More information

Installation and Operation Manual

Installation and Operation Manual Wireless Technology Enabled Exterior Digital Load Scale 201-EBT-02(B) Installation and Operation Manual Please read carefully before installation The Bluetooth word mark and logos are registered trademarks

More information

Installation Instructions

Installation Instructions Nov 25, 2013 Upper Control Arms Installation Instructions The following instructions are intended for professional installers and are guidelines only. Speedtech Performance assumes NO responsibility for

More information

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250 PFS Rotameter 09/2018 Rev. 0 Variable Area Flowmeter Instruction Manual PFS-RM200, RM230, RM250 Please note: This instruction manual provides detailed information and instructions that must be read, understood

More information

Model: SR635i Pediatric Scale with Cart Operating and Service Manual Part No.: MAN635i_ Page 1 of 18. Model SR635i. Pediatric Scale with Cart

Model: SR635i Pediatric Scale with Cart Operating and Service Manual Part No.: MAN635i_ Page 1 of 18. Model SR635i. Pediatric Scale with Cart Part No.: MAN635i_190123 Page 1 of 18 S by SInstruments, Inc. Model SR635i Pediatric Scale with Cart Operating and Service Manual Part No.: MAN635i_190123 Page 2 of 18 TABLE OF CONTENTS TABLE OF FIGURES...2

More information

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual Installation Instructions Tech Support: 856.768.8300 TechSupport@GlowShiftGauges.com DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual (1) Gauge (2) Controllers

More information

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger INTRODUCTION The Xantrex Digital echo-charge is specially developed for charging an auxiliary battery with Freedom TM or Fleet

More information

AD-7 THERMAL INDICATING AMMETER

AD-7 THERMAL INDICATING AMMETER AD-7 THERMAL INDICATING AMMETER a nd ACCESSORIES Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7.

More information

1014-SCR WARRANTY AND DISCLAIMER Fillmore Street Davenport, Ia

1014-SCR WARRANTY AND DISCLAIMER Fillmore Street Davenport, Ia 2036 Fillmore Street Davenport, Ia. 52804 563-324-1046 www.racedigitaldelay.com 1014-SCR WARRANTY AND DISCLAIMER DIGITAL DELAY INC. WARRANTS THE PRODUCTS IT MANUFACTURES AGAINST DEFECTS IN MATERIALS AND

More information

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS.   Version 1.0 AUTO-BLiP INTELLIGENT DOWNSHIFTS www.auto-blip.com User Manual Lotus Version 1.0 Copyright 2012 Tractive Technology, LLC. All rights reserved. Page 1 WARNING Use of the AUTO-BLiP while driving could lead

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS CM OPERATING INSTRUCTIONS 9 Function, Auto Range Digital Multi-Meter DM6450 INTERTEK Read this owner s manual thoroughly before use and save. C LISTED US I. DISPLAY FUNCTIONS & SYMBOLS 9 6 10 11 14 8 7

More information

UTV-1200 Multi Gauge for 2008 Yamaha Rhino

UTV-1200 Multi Gauge for 2008 Yamaha Rhino IMPORTANT NOTE! This gauge has an hour meter and odometer preset option available only for the first 1.0 engine hour and 10 miles (16km). See ODO/HR PRESET for instructions. UTV-1200 Multi Gauge for 2008

More information

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

AUTO-BLiP.   User Manual Chevrolet Corvette. Version 1.2 AUTO-BLiP INTELLIGENT DOWNSHIFTS www.auto-blip.com User Manual 1997-2004 Chevrolet Corvette Version 1.2 Copyright 2012 Tractive Technology, LLC. All rights reserved. Page 1 WARNING Use of the AUTO-BLiP

More information

Model Battery Powered Milliohm Meter

Model Battery Powered Milliohm Meter User s Guide Model 380580 Battery Powered Milliohm Meter Introduction Congratulations on your purchase of Extech s Model 380580 Battery Powered Milliohm Meter. This device offers five resistance ranges

More information

TL-105-D COLUMN HEATER

TL-105-D COLUMN HEATER TL-105-D COLUMN HEATER INSTRUCTION MANUAL Timberline Instruments Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com

More information