What NENS Means for You

Size: px
Start display at page:

Download "What NENS Means for You"

Transcription

1 What NENS Means for You A guide to Energy Networks Associa4on (ENA) New Standard for PPE for Electrical Arc Hazards October 2015 HTT Corp 2015 What NENS Means for You

2 NENS : Guideline to the selec4on, use and maintenance of PPE for electrical arc hazards

3 INTRODUCTION Energy Networks Associa4on (ENA) NENS09 update ENA has recently reviewed the NENS 09 Guideline in rela>on to electrical arc hazards, upda>ng the Guideline to reflect advances in both protec>ve technology and tes>ng capability. The purpose of these changes is to provide responsible organisa>ons with the ability to select suitable Personal Protec>ve Equipment (PPE) for workers dealing with both high and low voltage electrical systems. The primary change to the Guideline is the focus on Arc Rated (AR) clothing, being differen>ated from more commonly- used Flame Retardant (FR) clothing. Please note, this document is intended as an overview only. For full details on the NENS 09 standard, refer to SAI Global for your copy: hsp://infostore.saiglobal.com/store HTT Corp 2015 What NENS Means for You 3

4 SCOPE OF NENS Three areas of guideline coverage NENS 09 describes the following: Apparel design and features; Material performance requirements; Tes>ng methodologies and compliance requirements. The following pages provides a summary of each. HTT Corp 2015 What NENS Means for You 4

5 SCOPE OF NENS (CONT.) Apparel Base garments (long sleeve shirts, trousers, coveralls) are recommended to have a min. ATPV of 4cal/cm2, that is HRC1. Garment design is recommended to include the following: Shirt fronts closed (i.e. no opening) or where busons are used, the busons and openings should be covered by an addi>onal panel of material. Sleeve cuffs closed at wrist. E.g. cuff placket to include full gusset. Pockets manufactured from a covering layer of same material as base garment with FR thread. Vent material in base garments should be comprised of FR fabric and designed to ensure that ARC proper>es of the garment are not compromised. Material Arc rated fabrics are FR fabrics tested and proven to self ex>nguish when exposed to an arc event. Arc rated base garments worn if exposure >1.2cal/cm 2. Base garments: minimum ATPV HRC1 = 4cal/cm 2. Notably, all Arc Rated clothing is FR, but not all FR clothing is Arc Rated. HTT Corp 2015 What NENS Means for You 5

6 SCOPE OF NENS (CONT.) Compliance IEC : Live working Protec>ve clothing against the thermal hazards of an electric arc Part 2: Requirements. ASTM F1506: Standard performance specifica>on for tex>le material for wearing apparel use by electrical workers exposed to momentary electric arc and related thermal hazards. Test Methods IEC : Live working Protec>ve clothing against the thermal hazards of an electric arc Part 1: Test methods Method 1 Determina>on of the arc ra>ng (APTV or EBT50 of flame resistant materials for clothing). ASTM F1959: Standard Test Method for Determining the Arc Ra>ng of Materials for Clothing. HTT Corp 2015 What NENS Means for You 6

7 HTT ARC RATED HRC1 APPAREL RANGE

8 HTT AIRTEC AR ARC RATED HRC1 SHIRT Overview VENT: Maintains protec>ve covering, arc protec>on proper>es are not compromised. CUFF: Full gusset CLOSED/COVERED FRONT: Addi>onal placket of material covering opening zip MATERIAL: HRC 1 ATPV 6.8cal/cm 2 (weight 185gsm) HTT Corp 2015 What NENS Means for You 8

9 HTT AIRTEC AR ARC RATED HRC1 SHIRT Further Product Details Cer>fied NFPA 2112 Flash Fire Cer>fied EN ISO NFPA70E Electrical Arc Protec>on ASTM F1959 (HRC1: ATPV 6.8cal/cm 2* ) Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng Inherently FR Fabric FR Protec>on will not be compromised by washing or wear (unlike treated products) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Non Reflec4ve To meet day standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 9

10 HTT AIRTEC AR ARC RATED HRC1 COVERALL Overview VENT: Maintains protec>ve covering, arc protec>on proper>es are not compromised. CUFF: Full gusset CLOSED/COVERED FRONT: Addi>onal placket of material covering opening zip TAPE: FR material MATERIAL: HRC 1 ATPV 6.8cal/cm 2 (weight 185gsm) HTT Corp 2015 What NENS Means for You 10

11 HTT AIRTEC AR ARC RATED HRC1 COVERALL Further Product Details Cer>fied NFPA 2112 Flash Fire Cer>fied EN ISO NFPA70E Electrical Arc Protec>on ASTM F1959 (HRC1: ATPV 6.8cal/cm 2* ) Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng Inherently FR Fabric FR Protec>on will not be compromised by washing or wear (unlike treated products) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Available In Reflec4ve & Non Reflec4ve To meet either day- only or day/ night standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 11

12 HTT ARC RATED HRC2 APPAREL RANGE

13 HTT AIRTEC AR ARC RATED HRC2 SHIRT Overview VENT: Maintains protec>ve covering, arc protec>on proper>es are not compromised. CUFF: Full gusset CLOSED/COVERED FRONT: Addi>onal placket of material covering opening zip MATERIAL: HRC 2 ATPV 8cal/cm 2 (weight 230gsm) HTT Corp 2015 What NENS Means for You 13

14 HTT AIRTEC AR ARC RATED HRC2 SHIRT Further Product Details Cer>fied NFPA 2112 Flash Fire Cer>fied EN ISO NFPA70E Electrical Arc Protec>on ASTM F1959 (HRC2: ATPV 8.0cal/cm 2* ) Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng Inherently FR Fabric FR Protec>on will not be compromised by washing or wear (unlike treated products) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Non Reflec4ve To meet day standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 14

15 HTT AIRTEC AR ARC RATED HRC2 TROUSERS Overview MATERIAL: HRC 2 ATPV 8cal/cm 2 (weight 230gsm) TAPE: FR material HTT Corp 2015 What NENS Means for You 15

16 HTT AIRTEC AR ARC RATED HRC2 TROUSERS Further Product Details Cer>fied NFPA 2112 Flash Fire Cer>fied EN ISO NFPA70E Electrical Arc Protec>on ASTM F1959 (HRC2: ATPV 8.0cal/cm 2* ) Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng Inherently FR Fabric FR Protec>on will not be compromised by washing or wear (unlike treated products) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Available In Reflec4ve & Non Reflec4ve To meet either day- only or day/ night standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 16

17 HTT AIRTEC AR ARC RATED HRC2 COVERALL Overview VENT: Maintains protec>ve covering, arc protec>on proper>es are not compromised. CUFF: Full gusset CLOSED/COVERED FRONT: Addi>onal placket of material covering opening zip TAPE: FR material MATERIAL: HRC 2 ATPV 8cal/cm 2 (weight 230gsm) HTT Corp 2015 What NENS Means for You 17

18 HTT AIRTEC AR ARC RATED HRC2 COVERALL Further Product Details Cer>fied NFPA 2112 Flash Fire Cer>fied EN ISO NFPA70E Electrical Arc Protec>on ASTM F1959 (HRC2: ATPV 8.0cal/cm 2* ) Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng Inherently FR Fabric FR Protec>on will not be compromised by washing or wear (unlike treated products) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Available In Reflec4ve & Non Reflec4ve To meet either day- only or day/ night standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 18

19 HTT AIRTEC AR ARC RATED HRC2 RAIN JACKET Overview CLOSED/COVERED FRONT: Addi>onal placket of material covering opening zip TAPE: FR material MATERIAL: HRC 2 ATPV 17cal/cm 2 CUFF: Full gusset HTT Corp 2015 What NENS Means for You 19

20 HTT AIRTEC AR ARC RATED HRC2 RAIN JACKET Further Product Details ASTM 1959 (HRC2: ATPV 17.0cal/cm 2* ) High Visibility EN 471 High Visibility AS/ NZ4602.1:2011 Class D/N EN ISO 14116:2008 Index 3/5H/40 FR Performance Seam Sealing Performance test rated to 3psi for 2 minutes Wet weather performance level EN 343 Class 3 & 2 includes Moisture Vapour Transmission Rate for measurement of breathability in protec>ve garments Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng FR Fabric FR protec>on against heat and flame (ISO15025:2000 Procedure A) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Reflec4ve To meet either day- only or day/ night standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 20

21 HTT AIRTEC AR ARC RATED HRC2 RAIN TROUSERS Overview MATERIAL: HRC 2 ATPV 17cal/cm 2 TAPE: FR material HTT Corp 2015 What NENS Means for You 21

22 HTT AIRTEC AR ARC RATED HRC2 RAIN TROUSERS Further Product Details ASTM 1959 (HRC2: ATPV 17.0cal/cm 2* ) High Visibility EN 471 High Visibility AS/ NZ4602.1:2011 Class D/N EN ISO 14116:2008 Index 3/5H/40 FR Performance Seam Sealing Performance test rated to 3psi for 2 minutes Wet weather performance level EN 343 Class 3 & 2 includes Moisture Vapour Transmission Rate for measurement of breathability in protec>ve garments Excellent Electric Arc/Flash Fire Performance Superior protec>on as confirmed by independent tes>ng FR Fabric FR protec>on against heat and flame (ISO15025:2000 Procedure A) Superior Moisture Transfer & Evapora4on Highly breathable fabric means far greater user comfort Reflec4ve To meet either day- only or day/ night standards *The arc ra>ng test results are independently tested in accordance to the ASTM F1959 standard. HTT Corp 2015 What NENS Means for You 22

23 CONCLUSION Where to from here? In order to equip workers and others dealing with electrical arc hazards with suitable PPE, organisa>ons should follow the updated NENS 09 Guidelines from ENA. The emphasis on Arc Rated (AR) clothing (as opposed to FR only) will require an assessment of currently issued PPE and the determina>on of new garment supply required to comply with the updated Guidelines. The HTT NENS 09 compliant garment range is denoted by the following symbols: Our specialist team are available to advise on masers rela>ng to both the NENS 09 standard and apparel selec>on. HTT Corp 2015 What NENS Means for You 23

24 CONTACT Your strategic safety partners HTT Corp products are sold through a growing global network of carefully selected and valued strategic alliance distributors. For more informa>on about purchasing in your geographical or commercial area, and for more personal service, please contact: Alan Williamson (CEO) alanw@hscorp.com.au. HTT Corp 2015 What NENS Means for You 24

25 HTT CORPORATION 37 Doody Street, Alexandria NSW Australia 2015 hfcorp.com.au

INDEX. Long Sleeve T-Shirt One pocket with harness tape configuration. Hooded Sweatshirt Zipper front closurre with 2 pockets

INDEX. Long Sleeve T-Shirt One pocket with harness tape configuration. Hooded Sweatshirt Zipper front closurre with 2 pockets #2013-9/15 INDEX Class 2 FR Vests... 3 Lightweight and affordable, Class 2 vests conform to ASTM F1506 and are available in 3 styles: Standard Traditional vest layout with harness tape configuration and

More information

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification Table 3-3.9.1 Hazard Risk Classification Table 3-3.9.1 Hazard Risk Classification Panelboards rated 240 V and below Notes 1 and 3 - - - Circuit breaker (CB) or fused switch operation with covers on 0 N

More information

Live Line Technology Arc Flash suits

Live Line Technology Arc Flash suits Live Line Technology Arc Flash suits LLT ARC Fllash suiitts ffrom :: ATPV 12 CAL 140 CAL Live Line Technology Arc flash suits provide full body protection. LLT Arc Save Flash suit consists of the following

More information

ARC FLASH MANAGEMENT REVIEW. October 2017

ARC FLASH MANAGEMENT REVIEW. October 2017 ARC FLASH MANAGEMENT REVIEW October 2017 PURPOSE: The issue of Arc Flash Exposure has been knocking around for the past couple of months but unsure if we all understand the issue with this item and how

More information

PRO-WEAR ARC FLASH PROTECTION CLOTHING & KITS

PRO-WEAR ARC FLASH PROTECTION CLOTHING & KITS PRO-WEAR ARC FLASH PROTECTION CLOTHING & KITS 18 SALISBURY 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL 60440 U.S.A. Toll Free:877.406.4501 U.S.A. Toll Free Fax:866.824.4922 ALL PRO-WEAR ARC FLASH PROTECTION

More information

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit.

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit. 3018 Eastpoint Parkway Louisville, KY 40223 (502) 716-7073 January 30, 2006 Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT Re: NFPA 70E Hazard Assessment Date of Visit January 24, 2006

More information

REFLECTIVES FOR EVERYONE.

REFLECTIVES FOR EVERYONE. VISIBILIT Y SPEAKS SAFE T Y Reflective Rain Wear Reflective T-Shirts REFLECTIVES FOR EVERYONE. Reflective Bag Piping Reflective Jackets Reflective Shoe Piping ABOUT US REFLECTOSAFE IS THE PIONEER IN REFLECTIVITY

More information

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 * SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 * PRODUCT: Driver Suits 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating and

More information

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise Arc flash solutions catalogue Australia Safety solutions - Protecting employees and the enterprise The risk of an arc flash event is real An arc flash hazard is a proven significant and dangerous threat

More information

take to complete our safety compliance

take to complete our safety compliance This presentation is one of three steps you will take to complete our safety compliance requirements ECR Energizer Contractor Representative Primaryliaison between Energizer and the contractor for matters

More information

PARKA: HI-VISION 74 HB SCHUTZBEKLEIDUNG

PARKA: HI-VISION 74 HB SCHUTZBEKLEIDUNG Gisela Ragnit, Sales Support PARKA: HI-VISION 74 HB SCHUTZBEKLEIDUNG The reflective properties of HB Schutzbekleidung are positive in every respect both regarding visibility and design. Our products are

More information

INCIDENT COMMAND PONCHOS: LHV-5ANSI-IC or HV-5ANSI-IC ANSI CLASS 2

INCIDENT COMMAND PONCHOS: LHV-5ANSI-IC or HV-5ANSI-IC ANSI CLASS 2 LHV-5ANSI (Available in Lime or Orange) Visi-Cool ANSI Mesh 2" 3M silver reflective stripes PROTECTION ANSI-107-1999 COMPLIANT LH V-4ANSI-PC (Lime o nly) Fluorescent Lime/Yellow with 3 pkts Imported LH

More information

Short Circuit/Coordination & Arc Flash Study Specifications

Short Circuit/Coordination & Arc Flash Study Specifications Delphi Short Circuit/Coordination & Arc Flash Study Specifications April 28, 2005 Short Circuit/Coordination & Arc Flash Specification Table of Contents I. General Overview 3 II. Engineering Firm Requirements..

More information

Illinois State University. Electrical Safety Procedure

Illinois State University. Electrical Safety Procedure Illinois State University Electrical Safety Procedure Illinois State University Facilities Management Revision Date: May 2014 Illinois State University Facilities Management Electrical Safety Procedure

More information

DEHNcare protects Workers exposed to Arc Faults

DEHNcare protects Workers exposed to Arc Faults DEHNcare protects Workers exposed to Arc Faults www.dehn.de Enhanced safety and excellent wearing comfort 2 Why arc fault protection? Each and every day electrical work is carried out all over the world.

More information

Kumho Corporate Clothing Catalogue 2013

Kumho Corporate Clothing Catalogue 2013 Kumho Corporate Clothing Catalogue 2013 business attire workwear HiVis polo shirts jackets headwear sporting teams Contact: Belinda Thwaites, Sales Manager w www.harbourcityclothing.com.au e belinda@harbourcityclothing.com.au

More information

ELECTRICAL PERSONAL PROTECTIVE EQUIPMENT STANDARD

ELECTRICAL PERSONAL PROTECTIVE EQUIPMENT STANDARD Suncor-Wide Standard ELECTRICAL PERSONAL PROTECTIVE EQUIPMENT STANDARD Effective: On Date Approved Owned by Director of Maintenance and Reliability Services Reviewed every 5 years Livelink ID: 251254973

More information

BP-Husky Refinery Toledo, OH

BP-Husky Refinery Toledo, OH BP-Husky Refinery Toledo, OH Document Type: Procedure Refinery Wide Procedure No.: SAF 095 Effective Date: 2/25/16 Owner: D. Clark Working on or near Energized Electrical Equipment Rev. No.: 6 Auth. By:

More information

NESC 2007 FLAME RESISTANT CLOTHING

NESC 2007 FLAME RESISTANT CLOTHING NESC 2007 FLAME RESISTANT CLOTHING Written by: Hugh Hoagland Published: Friday, February 1, 2008 by Incident Prevention, Inc. The NESC 2007 standard sets forth quite a challenge to electric and communication

More information

TECHNICAL TOPICS UNIVERSITY. General Electrical Safety BEST PRACTICES

TECHNICAL TOPICS UNIVERSITY. General Electrical Safety BEST PRACTICES UNIVERSITY TECHNICAL TOPICS BEST PRACTICES General Electrical Safety Abstract Electrical systems by nature are considered extremely dangerous to most human beings as these systems operate under conditions

More information

Add face and hearing protection to any hard hat with ELVEX QuickSnap System in just four easy steps!

Add face and hearing protection to any hard hat with ELVEX QuickSnap System in just four easy steps! Add face and hearing protection to any hard hat with ELVE QuickSnap System in just four easy steps! 1. Hard Hat Select your current hard hat from adjacent chart. YOUR HARD HAT HERE a. QuickSnap TM Slot

More information

600 V Class Switchgear ( with power circuit breakers or fused Opening hinged covers (to expose bare, energized electrical - Note 1. switches) --Note 4

600 V Class Switchgear ( with power circuit breakers or fused Opening hinged covers (to expose bare, energized electrical - Note 1. switches) --Note 4 GearArc Safety This guide shall only be used in conjunction with performing the necessary calculations contained in a flash hazard analysis to determine the proper cal/cm². If the results of the calculations

More information

Type. Call +44 (0)

Type. Call +44 (0) Disposable Coverall and Lab Coat Cleanroom Apparel Integrity Cleanroom Apparel products are designed and manufactured to meet the stringent demands of the cleanroom industry. Manufactured from a lightweight,

More information

AS AS Australian Standard. Starter batteries Lead acid. This is a free 6 page sample. Access the full version online.

AS AS Australian Standard. Starter batteries Lead acid. This is a free 6 page sample. Access the full version online. AS 2149 2003 AS 2149 Australian Standard Starter batteries Lead acid This Australian Standard was prepared by Committee EL-005, Secondary Batteries. It was approved on behalf of the Council of Standards

More information

Safety Working with LV Drives

Safety Working with LV Drives US1008e_LV Drive Safety_C, April 2009 Safety Working with LV Drives Intended Audience Only qualified electricians and engineers are allowed to install and maintain a LV Drive Students of this training

More information

NFPA 70E Electrical Safety in the Work Place. R. Casey 2/1/05

NFPA 70E Electrical Safety in the Work Place. R. Casey 2/1/05 NFPA 70E Electrical Safety in the Work Place R. Casey 2/1/05 The Other Electrical Hazard Arc flash: high-intensity intensity flash (eye damage) and superheated ball of gas (skin burns and melting)created

More information

Van Puijenbroek Texti& CE TYPE EXAMINATION CERTIFICATE Nr

Van Puijenbroek Texti& CE TYPE EXAMINATION CERTIFICATE Nr In application of the directive 89/686/EEG of 21 December 1989 concerning the harmonisation of the Member States legislation relative to personal protective equipment, Centexbel Notified body 0493 authorised

More information

Salisbury by Honeywell 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL U.S.A. Toll-free: U.S.A. Toll-free Fax:

Salisbury by Honeywell 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL U.S.A. Toll-free: U.S.A. Toll-free Fax: Face, head & neck PROTECTION 14 Salisbury by Honeywell 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL 60440 U.S.A. Toll-free:877.406.4501 U.S.A. Toll-free Fax:866.824.4922 AS2000HAT PROTECTIVE Face SHIELD

More information

ORDERING STEPS STEP 4 STEP 5 STEP 1 STEP 6 STEP 2 STEP 3 THANK YOU FOR SHOPPING AT TBS THE TEAM AND CORPORATE STORE

ORDERING STEPS STEP 4 STEP 5 STEP 1 STEP 6 STEP 2 STEP 3 THANK YOU FOR SHOPPING AT TBS THE TEAM AND CORPORATE STORE RMH 2017 ORDERING STEPS ALL RMH ORDERS MUST BE PROCESSED ONLINE & GO THROUGH TEAM MANAGERS STEP 1 Open this Web Address http://www.getitattbs.com/sports-association/ in either Safari, Google Chrome, Internet

More information

Protective clothing and workwear

Protective clothing and workwear Protective clothing and workwear 19 Conversion chart 499 easyprotect365+ protection for high pressure cleaning 498-499 R+M / Suttner team wear 496 Safety spectacles, safety goggles and face shields 497

More information

Safe Working on or near low voltage electrical installations & equipment

Safe Working on or near low voltage electrical installations & equipment Safe Working on or near low voltage electrical installations & equipment Guidance Notes Version 1.11 28 June 2017 Gippsland Water Document Details Business Owner Procedure Process Owner/s Document Title

More information

7.4VOLT JACKETS AND VESTS USER MANUAL FOLLOW US

7.4VOLT JACKETS AND VESTS USER MANUAL FOLLOW US 7.4VOLT JACKETS AND VESTS USER MANUAL FOLLOW US Introduction Thank you for purchasing our battery powered Bluetooth Performance Heated Jacket or Vest. To ensure proper use and care of your garment and

More information

NEW PRODUCTS. As to: 20 March 2016

NEW PRODUCTS. As to: 20 March 2016 NEW PRODUCTS As to: 20 March 2016 ADLER Czech, a.s. Hall 3A, 83 1V9 HV PROTECT Unisex T-shirt in fluorescent colour from 55% cotton and 45% polyester, round neck lined with rib knit 1:1, certified retroreflective

More information

AECI Health, Safety & Environmental Procedures. Electrical Safety

AECI Health, Safety & Environmental Procedures. Electrical Safety 1. Purpose This procedure provides guidance for all personnel that work with or around electrical equipment. It is also the intent of this procedure to comply with 29 CFR 1910.269, 29 CFR 1910 Subpart

More information

Electrical Safety CSA Z462 & NB Regulations

Electrical Safety CSA Z462 & NB Regulations Electrical Safety CSA Z462 & NB Regulations WorkSafeNB s 2014 Health and Safety Conference Daniel Roberts Senior Manager, Electrical Safety Consulting at Schneider Electric Vice-chair CSA Z462 daniel.roberts@schneider-electric.com

More information

KLEENGUARD* Protective clothing

KLEENGUARD* Protective clothing KLEENGUARD* Protective clothing Protective clothing legislation Product selector A comprehensive range of apparel products providing the most appropriate personal to meet your needs. Selecting the right

More information

Recipient. Ultra Lightweight UPF 1/4 Zip Pullover Suggested Retail $ $42.00

Recipient. Ultra Lightweight UPF 1/4 Zip Pullover Suggested Retail $ $42.00 Ultra Lightweight UPF 1/4 Zip Pullover Suggested Retail $ 70.00 $42.00 Qty: 52 21 19 12 BC2337 Ultra-lightweight body fabric provides cool comfort UPF 25+ for sun protection on moderate days Easily packable

More information

M12 CORDLESS HEATED GEAR

M12 CORDLESS HEATED GEAR M12 CORDLESS GEAR Powered by M12 REDLITHIUM Battery Technology, Milwaukee M12 Cordless Heated Gear distributes heat across core body areas and stops cold dead in its tracks. Durable carbon fiber heating

More information

2016/2017 PATENT PENDING. thepowergripz.com

2016/2017 PATENT PENDING. thepowergripz.com 2016/2017 PATENT PENDING thepowergripz.com GLOVE SPECS GET A GRIP ON SAFETY Ultimately linemen know keeping the power on is all in their hands. But ordinary gloves just weren t designed for the real world,

More information

Morning Pride Clothing

Morning Pride Clothing Five Operational Models of Protective Clothing Model #4 Wildland Clothing Wildland Clothing is Available in Many Forms: There are two ways to purchase Wildland certified clothing product from Morning Pride:

More information

A Case Study: Review of Flammability Product Testing, the Similarities and Differences Ellen Roaldi Bureau Veritas Consumer Products Services

A Case Study: Review of Flammability Product Testing, the Similarities and Differences Ellen Roaldi Bureau Veritas Consumer Products Services A Case Study: Review of Flammability Product Testing, the Similarities and Differences Ellen Roaldi Bureau Veritas Consumer Products Services September 22, 2016 Agenda Methods Analysis Applicability Requirements

More information

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926) OSHA Update Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926) 5/14/2014 Significant Changes to the Standards General Training Host Employer & Contractor Responsibilities

More information

Integrating Roles Within Electric Utilities to Achieve Arc Flash Safety. MIPSYCON Presenters Neil Stiller & Bob Cooke

Integrating Roles Within Electric Utilities to Achieve Arc Flash Safety. MIPSYCON Presenters Neil Stiller & Bob Cooke Integrating Roles Within Electric Utilities to Achieve Arc Flash Safety MIPSYCON - 2018 Presenters Neil Stiller & Bob Cooke Presenters Neil Stiller, Sr. Electrical Engineer, RPU 30 years utility experience,

More information

New 2002 NEC. Arc Flash Hazard Marking Requirement Cooper Bussmann, Inc.

New 2002 NEC. Arc Flash Hazard Marking Requirement Cooper Bussmann, Inc. 110.16 New 2002 NEC Arc Flash Hazard Marking Requirement 2001 Cooper Bussmann, Inc. 110.16 Flash Protection. Switchboards, panelboards, industrial control panels, and motor control centers in other than

More information

Electrical Work (CPC-ALL-HSE-PRC-167)

Electrical Work (CPC-ALL-HSE-PRC-167) (CPC-ALL-HSE-PRC-167) DRM Retention Code: CG01 - CA Document to be reviewed every 2 years or less versions of this document are valid to be used until notified of revision via the Document Control Process.

More information

Electrical Safe Work Practices

Electrical Safe Work Practices Electrical Safe Work Practices Responsible Official: Matthew Early, VP for Campus Services Administering Division/Department: Facilities Management Effective Date: April, 22 Policy Sections: I. Purpose

More information

6990 Series Hybrid MatTop Chain Product Brochure. Rexnord 6990 Series Hybrid MatTop Chain

6990 Series Hybrid MatTop Chain Product Brochure. Rexnord 6990 Series Hybrid MatTop Chain 6990 Series Hybrid MatTop Chain Product Brochure Rexnord 6990 Series Hybrid MatTop Chain Breakthrough Automotive Solution Count on Rexnord 6990 Series Hybrid MatTop Chain to support you in your automotive

More information

Electrical Safety in Die Casting

Electrical Safety in Die Casting Electrical Safety in Die Casting April 2016 Beau Glim NADCA Project Manager NADCA Safety Series 4 parts Basic Safety Machine Maintenance Safety Electrical Safety Managing Safety General safety information

More information

BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE SUSTAINABLE

BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE SUSTAINABLE BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE SUSTAINABLE Ballasted EPDM Roofing Systems BALLASTED ROOFING SYSTEMS The ballasted system was the first roofing system introduced by Carlisle in the

More information

Hybrid & Electric Cars Guidance for organisers of Speed events

Hybrid & Electric Cars Guidance for organisers of Speed events Hybrid & Electric Cars Guidance for organisers of Speed events Electric vehicles rely on stored electrical energy to power an electric motor to provide propulsion. Hybrids are primarily powered by an internal

More information

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards Robert P. Hansen, P.E., PhD GE Specification Engineer Introduction Switchboards are a widely used type of equipment

More information

issue october 2017February 2018 Brown Rock Salt 27kg Walk Behind Salt Spreader 35Ltr Salt Spreader 50kg Yellow Salt Grit Bin

issue october 2017February 2018 Brown Rock Salt 27kg Walk Behind Salt Spreader 35Ltr Salt Spreader 50kg Yellow Salt Grit Bin issue 28 october 2017February 2018 Brown Rock Salt Brown Rock Salt 1 tonne bag 25kg bag 6.50 each 20 bags 5.50 each 49 bags 3.95 each 1 bag 831SALT 110.00 831SALT02 27kg Walk Behind Salt Spreader 35Ltr

More information

Lesson 5 4-Hour Version Slide: 4H-90

Lesson 5 4-Hour Version Slide: 4H-90 Lesson 5 4-Hour Version Slide: 4H-90 Lesson Objectives 4-Hour Version Slide: 4H-91 Lesson Objective: 5.1 4-Hour Version Slide: 4H-92 Making responder vehicles more visible improves safety by reducing the

More information

Electrical Safety - Protecting Yourself Against Electrical Injuries. from NIOSH Electrical Safety Student Manual

Electrical Safety - Protecting Yourself Against Electrical Injuries. from NIOSH Electrical Safety Student Manual Electrical Safety - Protecting Yourself Against Electrical Injuries from NIOSH Electrical Safety Student Manual Oct 9 11:26 AM 1 Electricity is Dangerous There is a risk of an electrical injury - 1. Whenever

More information

Heavy Vehicle Visibility

Heavy Vehicle Visibility Heavy Vehicle Visibility Industry Technical Council Advisory Procedure Printed by 3M Traffic Safety Systems in the interest of improving truck safety, through greater visibility Disclaimers This Code of

More information

Agenda / ESPS Electrical Safety Program Solutions INC.

Agenda / ESPS Electrical Safety Program Solutions INC. PEM Partners in Training Asset Management & Reliability Risk Assessment in the new CSA Z462 Electrical Power Distribution Reliability & Safety, a Valuable Balance Terry Becker, P.Eng., NFPA CESCP Owner,

More information

Medical & Surgical Lighting Pty Ltd SERIES 1 & 3 MEDICAL EXAMINATION LIGHTS

Medical & Surgical Lighting Pty Ltd SERIES 1 & 3 MEDICAL EXAMINATION LIGHTS Medical & Surgical Lighting Pty Ltd SERIES 1 & 3 MEDICAL EXAMINATION LIGHTS Introduction Medical & Surgical Lighting Pty Ltd (MSL) is an Australian company specialising in the design and manufacture of

More information

BP OIL -- TOLEDO REFINERY

BP OIL -- TOLEDO REFINERY BP OIL -- TOLEDO REFINERY Document Type: Procedure Effective Date: August 31, 2017 Owner: Dane P. Clark Refinery Wide Electrical Distribution System Switching and Isolation Auth. By: Rick J. Chmelovski

More information

Professional Insulated Tools. Supporting Arc Flash Protection. Updated 3/1/10. Innovations that work. 10,000 Volt Tested 1000 Volt Rated

Professional Insulated Tools. Supporting Arc Flash Protection. Updated 3/1/10. Innovations that work. 10,000 Volt Tested 1000 Volt Rated Professional Insulated Tools Supporting Arc Flash Protection Updated 3/1/10 Innovations that work 10,000 Volt Tested 1000 Volt Rated 2 Toll Free: (800) 494-6104 Arc Flash Protection: Wiha Insulated tools

More information

Second Correlating Revision No. 3 NFPA [ Section No ]

Second Correlating Revision No. 3 NFPA [ Section No ] Second Correlating Revision No. 3 NFPA 1991 2015 [ Section No. 2.3.2 ] 2.3.2 ASTM Publications. American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428 2959. ASTM

More information

BRAKE FLUIDS HIGH PERFORMANCE FOR YOUR BRAKING SYSTEM

BRAKE FLUIDS HIGH PERFORMANCE FOR YOUR BRAKING SYSTEM BRAKE FLUIDS HIGH PERFORMANCE FOR YOUR BRAKING SYSTEM BRAKE FLUIDS Haltermann Carless offers an extensive range of automotive coolants, brake fluids and screen washes. These products are formulated to

More information

TAMPA ELECTRIC COMPANY ENERGY SUPPLY ELECTRICAL SAFETY PROGRAM

TAMPA ELECTRIC COMPANY ENERGY SUPPLY ELECTRICAL SAFETY PROGRAM TABLE OF CONTENTS TITLE PAGE # PURPOSE / INTRODUCTION 1 SCOPE 2 RESPONSIBILITY 3 EMPLOYEE TRAINING INCLUDING DOCUMENTATION 4 ELECTRICAL EQUIPMENT LABELING 5 APPROACH DISTANCES AND BOUNDARIES 5 8 GENERAL

More information

Two Recent Case Studies in the Mining Industry

Two Recent Case Studies in the Mining Industry Two Recent Case Studies in the Mining Industry Remote Isolation Arc Flash Remediation David B. Durocher Senior Member, IEEE Global Industry Manager, Mining Eaton Corporation 26850 SW Kinsman Rd Wilsonville,

More information

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV.

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV. Description: EDITION : A 018331003(L4 FFL-201 ANZ) manual artwork SCALE : 100% PART NO ITEM ID REV. 961001550 MODEL NO 018331003 COLOR Black CM00166845 DIELINE 01 SIZE unfold:280mmx203mm; fold:70mmx26mm(+/-2mm)

More information

HYDRAULIC HOSES AND HOSE KITS

HYDRAULIC HOSES AND HOSE KITS HYDRAULIC HOSES AND HOSE KITS Liebherr Hydraulic Hoses and Hose Kits Liebherr-Australia Hose Production has been manufacturing high pressure hose assemblies in the Adelaide Head Office complex since 1999,

More information

Rexnord 6990 Series Hybrid MatTop Chain Product Brochure. Rexnord 6990 Series Hybrid MatTop Chain

Rexnord 6990 Series Hybrid MatTop Chain Product Brochure. Rexnord 6990 Series Hybrid MatTop Chain Rexnord 6990 Series Hybrid MatTop Chain Product Brochure Rexnord 6990 Series Hybrid MatTop Chain Automotive Solution Breakthrough 6990 Series H4 Hybrid MatTop Chain Rexnord 6990 Series Hybrid H4 MatTop

More information

A flexible solution for a tough problem: What are the solutions available for conveyor belt repair?

A flexible solution for a tough problem: What are the solutions available for conveyor belt repair? A flexible solution for a tough problem: What are the solutions available for conveyor belt repair? http://files.belzona.com/mrktg/picture conveyor belt repair.zip Conveyor belts are an integral part and

More information

GM PRODUCT OVERVIEW: HARLEy-DAVIDSON BUILT-IN TEMPERATURE CONTROLLER 12V HEATED GEAR. KEy FEATURES

GM PRODUCT OVERVIEW: HARLEy-DAVIDSON BUILT-IN TEMPERATURE CONTROLLER 12V HEATED GEAR. KEy FEATURES GM PRODUCT OVERVIEW: HARLEy-DAVIDSON BUILT-IN TEMPERATURE CONTROLLER 12V HEATED GEAR HARLEY-DAVIDSON HEATED CLOTHING IS DESIGNED TO KEEP RIDERS WARM AND EXTEND THEIR RIDING SEASON BY COMBATING THE COLD.

More information

crux event shell clothing Torq jacket Torq smock Torq pants Down clothing Halo top Plasma jacket Sleeping bags Torpedo 500 Torpedo 700 Torpedo 900

crux event shell clothing Torq jacket Torq smock Torq pants Down clothing Halo top Plasma jacket Sleeping bags Torpedo 500 Torpedo 700 Torpedo 900 crux spring/summer 09 update shell clothing Torq jacket Torq smock Torq pants Down clothing Halo top Plasma jacket Sleeping bags Torpedo 500 Torpedo 700 Torpedo 900 Amendments to main catalogue The Flak

More information

California State University Bakersfield Electrical Safety Program. Revised November 2017

California State University Bakersfield Electrical Safety Program. Revised November 2017 California State University Bakersfield Electrical Safety Program Revised November 2017 THIS PAGE INTENTIONALLY LEFT BLANK Contents 1.0 PURPOSE... 3 2.0 SCOPE... 3 3.0 REFERENCES... 4 4.0 DEFINITIONS...

More information

POPULAR PLACEMENT GUIDE. Back Hat Max Size: 3½ W x 1½ H. Front of Cap Max Size: 2-2½ H subject to design and approval

POPULAR PLACEMENT GUIDE. Back Hat Max Size: 3½ W x 1½ H. Front of Cap Max Size: 2-2½ H subject to design and approval POPULAR PLACEMENT GUIDE EMBROIDERY Collar Tip Men s Max Size: 1 H Women s Max Size: 1 H Men s Max Size: Women s Max Size: 4½ W On Collar 1 H x 3½ W Left/Right Back Shoulder Max Size: 4½ W Max Size: Below

More information

Arc Flash Resistant Equipment

Arc Flash Resistant Equipment Arc Flash Resistant Equipment Course No: E02-019 Credit: 2 PDH Velimir Lackovic, Char. Eng. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F:

More information

Arc flash hazard mitigation

Arc flash hazard mitigation Low Voltage Products Arc flash hazard mitigation Each year more than 2,000 people are treated in burn centers with severe arc flash injuries. ABB designs and manufactures products and solutions to provide

More information

KAMLOOPS MINOR HOCKEY ASSOCIATION APPAREL PRICING INFORMATION

KAMLOOPS MINOR HOCKEY ASSOCIATION APPAREL PRICING INFORMATION KAMLOOPS MINOR HOCKEY ASSOCIATION APPAREL PRICING INFORMATION 2012-13 Table of Contents Pages 3-5 Page 6-7 Page 8-9 Page 10-11 Page 12 Page 13 Page 14 Page 15 Bauer Apparel Reebok Apparel Stormtech Apparel

More information

Night Work Specification

Night Work Specification Night Work Specification 1.0 Hours of Work The contractor is advised that most work for this contract will be carried out during night time hours. For the purposes of this contract night is defined as

More information

Definitions. Exposed part. Live or energized part. De-energized part

Definitions. Exposed part. Live or energized part. De-energized part Electrical Safety Definitions Exposed part Live or energized part De-energized part 1a Definitions De-energized exposed parts that are not locked/tagged are considered to be energized exposed parts 1b

More information

INSTALLATION GUIDELINE -SARAN VAPOR RETARDER FILM AND SARAN VAPOR RETARDER TAPE ITW INSULATION SYSTEMS

INSTALLATION GUIDELINE -SARAN VAPOR RETARDER FILM AND SARAN VAPOR RETARDER TAPE ITW INSULATION SYSTEMS INSTALLATION GUIDELINE -SARAN VAPOR RETARDER FILM AND SARAN VAPOR RETARDER TAPE ITW INSULATION SYSTEMS 1 SCOPE SARAN FILM AND SARAN TAPE APPLIED AS A VAPOR RETARDER ON MECHANICAL INSULATION SYSTEMS 1.1

More information

Jacket shown # Vests, T-Shirts, and Sweatshirts (Minimum order: 10) Jackets and Rainwear (Minimum order: 10)

Jacket shown # Vests, T-Shirts, and Sweatshirts (Minimum order: 10) Jackets and Rainwear (Minimum order: 10) * FREE LOGO SET-UP CHARGE until /1/1 Jacket shown #-1 Safety glass shown #-12 Hardhat shown #0-0 CUSTOM LOGO PRICING (Add to the price of the item. See item prices on pages 12-1) Vest shown #-00 Vests,

More information

Safety Training Topic ELECTRICAL SAFETY

Safety Training Topic ELECTRICAL SAFETY Safety Training Topic Purpose of Meeting To remind workers that electrical hazards can result in a serious injury. To reinforce electrical safety rules. To consider ways to protect yourself from electrical

More information

OIL & GAS INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE

OIL & GAS INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE OIL & GAS INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE ANSELL: A WORLD LEADER IN HEALTH AND SAFETY PROTECTIVE SOLUTIONS GLOBAL SALES, PRODUCTS AND SUPPLY CHAIN INFRASTRUCTURE,000 Employees

More information

DOWNLOAD OR READ : THE ELECTRIC ARC PDF EBOOK EPUB MOBI

DOWNLOAD OR READ : THE ELECTRIC ARC PDF EBOOK EPUB MOBI DOWNLOAD OR READ : THE ELECTRIC ARC PDF EBOOK EPUB MOBI Page 1 Page 2 the electric arc the electric arc pdf the electric arc An electric arc, or arc discharge, is an electrical breakdown of a gas that

More information

PROVIDING ACCURATE DATA IN A TIMELY MANNER

PROVIDING ACCURATE DATA IN A TIMELY MANNER PROVIDING ACCURATE DATA IN A TIMELY MANNER 248 Hughes Lane St. Charles MO 63301 Ph. (636) 949-5835 Fax (636) 723-5835 www.elteklabs.com MATERIAL PROPERTIES LAB TRACKING TESTS TEST METHOD UL 746-A Section

More information

Mark Lyvers LLC / Cooper Bussmann Arc Flash Script Script to accompany PowerPoint on New 2002 NEC Arc Flash Hazard Marking Requirement

Mark Lyvers LLC / Cooper Bussmann Arc Flash Script Script to accompany PowerPoint on New 2002 NEC Arc Flash Hazard Marking Requirement Mark Lyvers LLC / Cooper Bussmann Arc Flash Script Script to accompany PowerPoint on 110.16 New 2002 NEC Arc Flash Hazard Marking Requirement Slide 1 Suggestion on How to Use Download both the Mark Lyvers

More information

CARLISLE S BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE ENERGY EFFICIENT

CARLISLE S BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE ENERGY EFFICIENT CARLISLE S BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE ENERGY EFFICIENT Ballasted EPDM Roofing Systems CARLISLE S BALLASTED ROOFING SYSTEMS The ballasted system was the first roofing system introduced

More information

Submersible Sewage Pumps Type ABS XFP

Submersible Sewage Pumps Type ABS XFP Submersible Sewage Pumps Type ABS XFP Main Applications Submersible sewage pump type ABS XFP is designed for municipal and industrial wastewater equipped with Premium Efficiency (IE3 level) motor for:

More information

HONDA RACING SERIES DELTA SERIES

HONDA RACING SERIES DELTA SERIES GENUINE HONDA RIDING GEAR 2011 COLLECTION HONDA RACING JACKET Part Number : L08JK411130 Colour: Dark blue, red, white & orange. Sizes: 06/XS, 07/S, 08/M, 09/L, 10/XL, 11/2XL, 12/3XL Outer fabric 95% hardwearing

More information

Introduc)on to Nonwoven & Technical Tex)les. For AGC, AGCCA, and MIP Use Only

Introduc)on to Nonwoven & Technical Tex)les. For AGC, AGCCA, and MIP Use Only Introduc)on to Nonwoven & Technical Tex)les For AGC, AGCCA, and MIP Use Only Introduc)on to Nonwovens & Technical Tex)les Tex)le vs. Nonwoven Product applica)on Tex)le Tes)ng Non- woven tes)ng Grade recommenda)ons

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET Section 1: Chemical Product and Company Identification Part Number: Description: Customer Description: Customer Part Number: National Stock Code: U-BPU60-66 Lithium ion rechargeable

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CONSUMER TESTING LABORATORIES, INC. 2601 SE Otis Corley Drive Bentonville, AR 72712 Stephanie Anderson Phone: 479 286 2376 MECHANICAL Valid To: September 30,

More information

Safety Resources p r o d u c t i n d e x

Safety Resources p r o d u c t i n d e x PRODUCT INDEX Safety Resources p r o d u c t i n d e x A Accessories eye protection...................... 22 23 lighting............................. 224 respirator................... 89 91, 93 95 Accumulation

More information

Submersible Sewage Pumps Type ABS XFP

Submersible Sewage Pumps Type ABS XFP Submersible Sewage Pumps Type ABS XFP Main Applications Submersible sewage pump type ABS XFP is designed for municipal and industrial wastewater equipped with Premium Efficiency (IE3 level) motor for:

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33 CS ENERGY OPERATIONS PROCEDURE FOR MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33 Responsible Officer: Electrical Services Engineering Manager Responsible Manager: Group

More information

MEPC 71. The Impact on Ballast Water Management Compliance Plans

MEPC 71. The Impact on Ballast Water Management Compliance Plans MEPC 71 The Impact on Ballast Water Management Compliance Plans Meet Your Presenters Chris McMenemy Managing Director Naval Architect & Marine Engineer Involved in Ballast Water Management for nearly 10

More information

TMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product

TMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product Page 1 of 12 October 2015 Specification RW-2513 Document Number: 108-121016 TMS CABLE MARKERS CM-SCE & CM-SCE-TP Including HL cable marker range Tie on Identification Product SCOPE This quality assurance

More information

Professional Engineering Services. Service Focus. PowerChain Management Audit

Professional Engineering Services. Service Focus. PowerChain Management Audit Professional Engineering Services Service Focus PowerChain Management Audit A wel 2 eaton corporation PowerChain Management Audit lness check for your power system A well-managed power system is the foundation

More information

Project Low profile body armour Huijun Li University of Wollongong

Project Low profile body armour Huijun Li University of Wollongong Project 7.1.3 Low profile body armour Huijun Li University of Wollongong April 7, 2009 Capability through collaboration 2 Company overview 3 Company overview 4 Business model and governance 5 Personnel

More information

JHT ACN COMPANY INDUCTION JOHN HEGGART TRANSPORT. Ph: Fax: P.O BOX 1271 Warragul Vic

JHT ACN COMPANY INDUCTION JOHN HEGGART TRANSPORT. Ph: Fax: P.O BOX 1271 Warragul Vic JOHN HEGGART TRANSPORT PTY. LTD. ACN 094 311 243 COMPANY INDUCTION JOHN HEGGART TRANSPORT Ph:0356232231 Fax:0356232483 P.O BOX 1271 Warragul Vic 3820 Email: jht@dcsi.net.au Table of Contents. 1.0 JHT Goal

More information

PURPOSE POLICY. Page 1 of 6 / S.O.G Highway Operations Pascal Arnes Chief of Fire

PURPOSE POLICY. Page 1 of 6 / S.O.G Highway Operations Pascal Arnes Chief of Fire DECATUR TOWNSHIP FIRE DEPARTMENT STANDARD OPERATING GUIDELINE TITLE: HIGHWAY OPERATIONS SECTION: SAFETY NUMBER: 6.01 EFFECTIVE: JULY 1, 2014 THIS GUIDELINE SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES,

More information

A More Efficient Workplace Starts Here FPO. Aerospace Surface Prep and Paint

A More Efficient Workplace Starts Here FPO. Aerospace Surface Prep and Paint A More Efficient Workplace Starts Here FPO Aerospace Surface Prep and Paint Aerospace Surface Prep & Paint Your aerospace operation is focused on perfection in surface prep and paint. Part of this mission

More information