SF DIVISION FANS 1101 N. Redmond Rd., Jacksonville Arkansas Fax (501)

Size: px
Start display at page:

Download "SF DIVISION FANS 1101 N. Redmond Rd., Jacksonville Arkansas Fax (501)"

Transcription

1 TM Triangle Engineering TM 1101 N. Redmond Rd., Jacksonville Arkansas Fax (501) Revised 3/14

2 INDEX Terms and Conditions... 3 Series TAD Direct Drive Series TAB Belt Drive Series VAD Direct Drive Series VAB Belt Drive Series FHI Direct Drive Series FHI Belt Drive FHI Series Wall Boxes Jet Updraft Fans Hooded Fans TP High Velocity Fans Rooftop Accessories...back cover 2

3 TERMS AND CONDITIONS ORDER ACCEPTANCE Triangle Engineering reserves the right to accept or reject any and all orders. TERMS Terms net 30 days but at all times are subject to the approval of Triangle Engineering, hereafter referred to as Triangle Engineering. CLAIMS The responsibility of Triangle Engineering ceases upon delivery of goods in good order to the carrier. Claims for factory shortages and defects will not be considered unless made in writing to Triangle Engineering within ten days after receipt of the goods and accompanied by reference to our bill of lading and factory order numbers. As all goods are shipped at customer s risk, any claims for damage or shortage in transit must be filed by customer against the transportation company. TAXES The amount of any present or future taxes applicable to the product shall be added to the price contained herein and paid by the customer in the same manner and with the same effect as if originally added thereto. ORDER CHANGES Manufacturer processes orders immediately upon receipt. Therefore, any amendments to original order may be subject to new order classification, price and schedule. CANCELLATIONS Accepted orders may be cancelled only by written consent of Triangle Engineering and only after Triangle Engineering is fully reimbursed for any and all engineering and fabrication costs incurred up to date notice of request for cancellation is received. DELAYS Triangle Engineering shall not be liable for any delays caused by riots, strikes, fires, floods, lack of transportation, accidents, act or action of any of the various federal, state, municipal, or local governments, or any act of God, or any other contingency beyond its control. PRODUCT CHANGES In the interest of continuous product improvement, Triangle Engineering reserves the right to change specifications and/or design without incurring obligation. RETURNED GOODS Goods may not be returned except by express written permission of authorized factory officials of Triangle Engineering, Jacksonville, AR. and when so returned will be subject to restocking and handling charges and transportation costs. WARRANTY Upon payment of this invoice in full, the seller warrants those goods manufactured by it and sold hereby to be free of defects in material and workmanship only if properly installed, cared for, and operated with competent supervision under normal conditions as specified to us in writing. The seller s obligation under this warranty is limited to replacing or repairing at its option and at its own factory any defective part or parts thereof which shall, within one year after shipment by it to the original purchaser, be returned to its factory with transportation charges prepaid. Upon such repair or replacement all obligations under this warranty shall be deemed fulfilled and terminated. Triangle Engineering makes no warranty whatsoever in respect to parts or accessories not supplied by or installed by Triangle Engineering. The seller shall not be liable for any loss or damage whatsoever to any person, firm, or corporation, and shall not be liable or responsible for any repairs made outside of its own factory. There are no other warranties or representations, express or implied, made or effective upon this sale The above warranty supersedes and is in lieu of all other warranties express or implied which extend beyond the description contained herein. No person, firm, corporation, agent, or dealer is authorized to make any warranties on behalf of Triangle Engineering nor to assume for Triangle Engineering any liability in connection with any of Triangle Engineering s products. All quotations are subject to acceptance within sixty (60) days. Prices in quotation covering Triangle Engineering s manufactured products are firm for one year from date of order. All orders are subject to approval by Triangle Engineering All customer purchase orders are hereby made subject to the provisions of this acceptance and the seller s failure to object to provisions contained in customer s purchase orders or other communications shall not be deemed a waiver of the terms and conditions hereof nor acceptance of such provisions. No representations or guarantees other than those contained herein shall be binding upon Triangle Engineering unless made in writing and signed by an official of Triangle Engineering. NOTICE The Purchaser agrees, in exchange for the pricing schedules used in this transaction, that any litigation of any nature arising from this transaction, or in any other way related to the relationships involved herein shall be exclusively subject to venue, in personam and subject matter jurisdiction in any other court or courts in any other county or state are hereby waived; further, any transaction in which the Purchaser is a corporation, other than a corporation with publicly traded stock, is recognized to include the guaranty of performance from and by the principal shareholders thereof whose authorization of such guaranty is represented to have been secured prior to the first and subsequent transaction and which guaranty is evidenced through the corporation s purchase. 3

4 Tube Axial Direct Drive Series TAD TRIANGLE ENGINEERING Split Tapered Standard Drive Hubs permit easy removal of the fan from the shaft for maintenance purposes Standard finish: Coated with a polyester powder coat paint system for long life and superior corrosion resistance. Operation The TAD can operate in temperatures up to 150 F. subject to motor design tem perature limitations. Sizes TAD s are available in five (5) stan dard diameter sizes ranging from 24" through 48", with 22 motor options. Sizes other than standard are available upon request. NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. Applications For applications where corrosive or contaminated air streams are not encountered, the Series TAD Direct Drive Fan offers best performance and economy as well as minimum maintenance. Construction Featuring all-welded heavy gauge steel construction, the motor base pedestal is supported by a guide vane which prevents deflection that can result in poor fan performance. Options Access Doors are recommended for direct drive TAD fans when installed in duct system for drive inspection. Inlet or outlet Screen Guards are required when the fan installation is below 7 from the floor. Mounting Legs. Formed angle legs bolt to the fan housing flanges to facilitate wall or ceiling mounting. Companion Flanges are available to match fan flanges for duct installation. Inlet or Outlet Diffusers are available for increased fan efficiency and to connect to larger diameter duct sections. 4

5 TRIANGLE ENGINEERING Direct Drive Series TAD 4 Blades 6 Blades DIRECT DRIVE MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 1.25"SP 1.50"SP 1.75"SP TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD TAD MODEL BLADE DIMENSIONS HOUSING NO. DIA. A B C D E F GaugeS TAD TAD TAD TAD TAD

6 Tube Axial Belt Drive Series TAB TRIANGLE ENGINEERING Construction The TAB is of rugged welded construction; and is designed to operate in any position. Standard mounting flanges on each end permit installation in walls, roofs, or duct systems. New motor mount design with jack screws for easy belt tensioning. Split Tapered Standard Drive Hubs per mit easy removal of the fan from the shaft for maintenance purposes Standard finish: Coated with a polyester powder coat paint system for long life and superior corrosion resistance. Sizes TAB s are available in five (5) stan dard diameter sizes ranging from 24" through 48", with 24 motor options. Sizes other than standard are available upon request. NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. Applications Designed for exhausting hazardous atmospheres and corrosive fumes, the motor, belt drive, and bearings of the TAB are isolated from the exhaust air stream to keep contaminated air or vapors from damaging the fan drive system. Typical applications include ex hausters for paint spray booths, mixing rooms, booster service, and many other industrial ventilation requirements. Options Inlet or outlet Screen Guards are required when the fan installation is below 7 from the floor. Mounting Legs. Formed angle legs bolt to the fan housing flanges to facilitate wall or ceiling mounting. Companion Flanges are available to match fan flanges for duct installa tion. Inlet or Outlet Diffusers are available for increased fan efficiency and to connect to larger diameter duct sections 6

7 TRIANGLE ENGINEERING Belt Drive Series TAB 4 Blades 6 Blades BELT DRIVE MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 1.25"SP 1.50"SP 1.75"SP TAB 24 1/ TAB 24 3/ TAB TAB TAB TAB 30 1/ TAB 30 3/ TAB TAB TAB TAB TAB TAB TAB TAB / TAB TAB TAB TAB / TAB TAB TAB TAB / TAB Other sizes available on request MODEL BLADE DIMENSIONS HOUSING No. Dia. A B C D E F GAUGES TAB / / /8 12 7/16 16 TAB / / /8 16 7/16 16 TAB / / /8 16 7/16 16 TAB / / /8 24 7/16 14 TAB / / /8 24 7/

8 Vane Axial Direct Drive Series VAD TRIANGLE ENGINEERING Standard finish: Coated with a polyester powder coat paint system for long life and superior corrosion resistance. NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. Applications For applications where corrosive or contaminated air streams are not encountered, the Series VAD Direct Drive Fan offers best performance and economy as well as minimum maintenance. Construction Featuring all-welded heavy gauge steel construction, the motor base pedestal is supported by a guide vane which prevents deflection that can result in poor fan performance. Split Tapered Standard Drive Hubs permit easy removal of the fan from the shaft for maintenance purposes Operation The VAD can operate in temperatures up to 150 F, subject to motor design temperature limitations. Sizes VAD s are available in five (5) standard diameter sizes ranging from 24" through 48", with 22 motor options. Sizes other than standard are available upon request. Options Access Doors are recommended for direct drive VAD fans when installed in duct system for motor inspection. Inlet or outlet Screen Guards are required when the fan installation is below 7 from the floor. Mounting Legs. Formed angle legs bolt to the fan housing flanges to facilitate wall or ceiling mounting. Companion Flanges are available to match fan flanges for duct installation. 8

9 TRIANGLE ENGINEERING Direct Drive Series VAD 4 Blades 6 Blades MODEL MTR. PEAK CFM NO. HP RPM BHP.00".10".125".25".375".50".75" 1.00" 1.25" 1.50" 1.75" 2.00" VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD VAD MODEL BLADE DIMENSIONS Housing NO. DIA. A B C D E F G Guage VAD / / /8 12 7/ VAD / / /8 16 7/ VAD / / /8 16 7/ VAD / / /8 24 7/ VAD / / /8 24 7/

10 Vane Axial Belt Drive Series VAB TRIANGLE ENGINEERING Construction The VAB is of rugged welded construction; and is designed to operate in any position. Standard mounting flanges on each end permit installation in walls, roofs, or duct systems. New motor mount design with jack screws for easy belt tensioning. Extended lubrication lines are standard for ease of maintenance lubrication. Split Tapered Standard Drive Hubs permit easy removal of the fan from the shaft for maintenance purposes Standard finish: Coated with a polyester powder coat paint system for long life and superior corrosion resistance. Sizes VAB s are available in five (5) standard diameter sizes ranging from 24" through 48", with 24 motor options. Sizes other than standard are available upon request. NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. Applications Designed for exhausting hazardous atmospheres and corrosive fumes, the motor, belt drive, and bearings of the VAB are isolated from the exhaust air stream to keep contaminated air or vapors from damaging the fan drive system. Typical applications include exhausters for paint spray booths, mixing rooms, booster service, and many other industrial ventilation requirements. Our pre-rotative straightening vanes boost the VAB capacity to give you low cost CFM at the highest efficiency. Options Inlet or outlet Screen Guards are required when the fan installation is below 7 from the floor. Mounting Legs. Formed angle legs bolt to the fan housing flanges to facilitate wall or ceiling mounting. Companion Flanges are available to match fan flanges for duct installation. 10

11 TRIANGLE ENGINEERING Belt Drive Series VAB MODEL MTR. PEAK CFM NO. HP RPM BHP.00".10".125".25".375".50".75" 1.00" 1.25" 1.50" 1.75" 2.00" 4 Blades 6 Blades VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB VAB DIMENSIONS MODEL BLADE DIMENSIONS Housing NO. DIA. A B C D E F Gauge VAB / / /8 12 7/16 16 VAB / / /8 16 7/16 16 VAB / / /8 16 7/16 16 VAB / / /8 24 7/16 14 VAB / / /8 24 7/

12 Panel Fan Direct Drive Series FHI TRIANGLE ENGINEERING NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. Standard Features Heavy duty cast aluminum propeller with Airfoil blades for quiet, efficient operation. Standard construction is 4-bladed propeller through 36" and 6-bladed propeller through 60". Other duties and arrangements are available. Consult factory. Deep spun venturi-type orifice for quieter, more efficient operation. Rugged all-welded structural frame for added support and lower vibration. Taper-lock bushing between propeller and shaft for ease of removal, should it become necessary. Motors are totally enclosed, fan cooled as standard. (Open motors are not recommended.) All available motor configurations (chemical type, 50 cy, etc.) are available as an option. Formed motor mounting plate to minimize vibration. Split Tapered Standard Drive Hubs per mit easy removal of the fan from the shaft for maintenance purposes Standard finish: Coated with a polyester powder coat paint system for long life and superior corrosion resistance. Accessory Equipment RAIN LOUVERS supplied in heavy duty galvanized steel to protect against rain on supply units. WALL BOXES for mounting to wall openings and/or for mounting screens or shutters. (Can also be used to convert wall fan into semi-portable spot or man cooler.) SHUTTERS are available in air, manual and electric motor operated types. DISCHARGE SCREENS are constructed of heavy gauge wire and of a mesh suitable for most industrial applications. 12

13 TRIANGLE ENGINEERING Direct Drive Series FHI ALL ANGLE OPERATION: Fan can be mounted vertically in a wall, horizontally in a roof with appropriate hood cover, or at any intermediate angle. FAN MOTOR PROPELLER DIMENSIONS MODEL HP RPM DIA. A B C D FHI-24-DD 1/ /2 9-1/2 3 FHI-24-DD 3/ /2 9-1/2 3 FHI-24-DD /2 9-1/2 3 FHI-24-DD 1-1/ /2 9-1/2 3 FHI-30-DD 1/ /2 10-1/2 3 FHI-30-DD 3/ /2 10-1/2 3 FHI-30-DD /2 10-1/2 3 FHI-30-DD /2 10-1/2 3 FHI-30-DD /2 10-1/2 3 FHI-36-DD 3/ /2 10-1/2 3 FHI-36-DD /2 10-1/2 3 FHI-36-DD /2 10-1/2 3 FHI-36-DD FHI-36-DD FHI-36-DD 7-1/ FHI-42-DD FHI-42-DD FHI-42-DD FHI-42-DD 7-1/ FHI-42-DD FHI-48-DD FHI-48-DD FHI-48-DD 7-1/ FHI-48-DD 7-1/ FHI-48-DD /2 16-1/2 3 FHI-48-DD /2 16-1/2 3 FHI-54-DD FHI-54-DD 7-1/ FHI-54-DD /2 16-1/2 3 FHI-60-DD FHI-60-DD 7-1/ /2 16-1/2 4 FHI-60-DD /4 15-1/2 4 13

14 Direct Drive Series FHI TRIANGLE ENGINEERING MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 4 Blades FHI-24-DD 1/ FHI-24-DD 3/ FHI-24-DD FHI-24-DD 1-1/ FHI-30-DD 1/ FHI-30-DD 3/ FHI-30-DD FHI-30-DD FHI-30-DD FHI-36-DD 3/ FHI-36-DD FHI-36-DD FHI-36-DD FHI-36-DD FHI-36-DD 7-1/ Blades MODEL MTR. TIP PEAK CFM MODEL NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP FHI-42-DD FHI-42-DD FHI-42-DD FHI-42-DD FHI-48-DD FHI-48-DD FHI-48-DD 7-1/ FHI-48-DD FHI-48-DD FHI-54-DD FHI-54-DD 7-1/ FHI-54-DD FHI-60-DD FHI-60-DD 7-1/ FHI-60-DD

15 TRIANGLE ENGINEERING Panel Fans Belt Drive Series FHI Taper lock bushing between propeller and shaft for ease of removal, should it become necessary. Heavy duty V belt drive with cast iron sheaves, dynamically balanced fan and motor sheaves and static free extra strength V belts. Variable speed motor sheaves, optional. Adjustable motor mount to allow belt adjustment; positioning jacks supplied as options. Split Tapered Standard Drive Hubs per mit easy removal of the fan from the shaft for maintenance purposes Standard finish: Coated with a polyester powder coat paint system for long life and superior corrosion resistance. NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. Standard Features Heavy duty cast aluminum propeller with Airfoil blades for quiet, efficient operation. Standard construction employs 4 bladed propeller through 36" and 6 bladed propeller through 84". Other duties and arrangements are available. Consult factory. Deep spun venturi type orifice for quieter, more efficient operation. Rugged all welded structural frame for added support and lower vibration. Heavy duty self aligning ball bearing pillow blocks, to insure long maintenance free operation. Accessory Equipment RAIN LOUVERS supplied in heavy duty galvanized steel to protect against rain on supply units. WALL BOXES for mounting to wall openings and/or for mounting screens or shutters. (Can also be used to convert wall fan into semi-portable spot or man cooler.) SHUTTERS are available in air, manual and electric motor operated types. DISCHARGE SCREENS are constructed of heavy gauge wire and of a mesh suitable for most industrial applications. 15

16 Belt Drive Series FHI TRIANGLE ENGINEERING FAN MOTOR PROPELLER DIMENSIONS MODEL HP RPM DIA. A B C D FHI-24-BD 1/ /2 9-1/2 3 FHI-24-BD 3/ /2 9-1/2 3 FHI-24-BD /2 9-1/2 3 FHI-24-BD 1-1/ /2 9-1/2 3 FHI-24-BD /2 9-1/2 3 FHI-30-BD 1/ /2 10-1/2 3 FHI-30-BD 3/ /2 10-1/2 3 FHI-30-BD /2 10-1/2 3 FHI-30-BD 1-1/ /2 10-1/2 3 FHI-30-BD /2 10-1/2 3 FHI-30-BD /2 10-1/2 3 FHI-30-BD /2 10-1/2 3 FHI-36-BD FHI-36-BD 1-1/ FHI-36-BD FHI-36-BD FHI-36-BD FHI-36-BD 7-1/ FHI-42-BD FHI-42-BD 1-1/ FHI-42-BD FHI-42-BD FHI-42-BD FHI-42-BD 7-1/ FHI-42-BD FHI-48-BD FHI-48-BD 1-1/ FHI-48-BD FHI-48-BD FHI-48-BD FHI-48-BD 7-1/ FHI-48-BD FHI-54-BD FHI-54-BD FHI-54-BD FHI-54-BD 7-1/ FHI-54-BD FHI-60-BD FHI-60-BD FHI-60-BD FHI-60-BD 7-1/ FHI-60-BD FHI-72-BD FHI-72-BD FHI-72-BD 7-1/ FHI-72-BD FHI-72-BD FHI-72-BD FHI-84-BD FHI-84-BD 7-1/ FHI-84-BD FHI-84-BD FHI-84-BD FHI-84-BD

17 TRIANGLE ENGINEERING Belt Drive Series FHI 4 BLADE CAST ALUMINUM PROPELLER MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP FHI-24-BD 1/ FHI-24-BD 3/ FHI-24-BD FHI-24-BD 1-1/ FHI-24-BD FHI-30-BD 1/ FHI-30-BD 3/ FHI-30-BD FHI-30-BD 1-1/ FHI-30-BD FHI-30-BD FHI-30-BD FHI-36-BD FHI-36-BD 1-1/ FHI-36-BD FHI-36-BD FHI-36-BD FHI-36-BD 7-1/

18 Belt Drive Series FHI TRIANGLE ENGINEERING 6 BLADE CAST ALUMINUM PROPELLER MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP FHI-42-BD FHI-42-BD 1-1/ FHI-42-BD FHI-42-BD FHI-42-BD FHI-42-BD 7-1/ FHI-42-BD FHI-48-BD FHI-48-BD 1-1/ FHI-48-BD FHI-48-BD FHI-48-BD FHI-48-BD 7-1/ FHI-48-BD FHI-54-BD FHI-54-BD FHI-54-BD FHI-54-BD 7-1/ FHI-54-BD FHI-60-BD FHI-60-BD FHI-60-BD FHI-60-BD 7-1/ FHI-60-BD FHI-72-BD FHI-72-BD FHI-72-BD 7-1/ FHI-72-BD FHI-72-BD FHI-72-BD FHI-84-BD FHI-84-BD 7-1/ FHI-84-BD FHI-84-BD FHI-84-BD FHI-84-BD

19 TRIANGLE ENGINEERING FHI Series WALL BOXES Standard sizes for use with FHI Belt-Drive and Direct Drive Fans B 1-1/2 FLANGE B A INSIDE INSIDE OUTSIDE BOX MOUNTED IN WALL/SHUTTER MOUNTED TO BOX BOX MOUNTED IN WALL/SHUTTER MOUNTED TO OUTSIDE OF WALL BOX MOUNTED THROUGH WALL/SHUTTER MOUNTED TO OUTSIDE OF BOX NOTE: A" DIMENSION WILL INCREASE 6" WHEN A BACKDRAFT DAMPER IS SPECIFIED TO BE MOUNTED INSIDE BOX. WHEN INSTALLATION OF FAN REQUIRES A SHUTTER, A MINIMUM OF 6" SHOULD BE ALLOWED BETWEEN FAN BLADE AND SHUTTER. CONSULT FACTORY FOR SPECIAL APPLICATIONS AND SIZES. BOX MODEL MOTOR HP A DIMENSION B DIMENSION HOLE SIZE FLANGE SIZE GAUGE S-24 1/4 HP-2 HP 22-1/2" 30-3/8" O.D. 30-3/4" X 30-3/4" 1-1/2" 16 3 HP 28-1/2" 30-3/8" O.D. 30-3/4" X 30-3/4" 1-1/2" 16 S-30 1/2 HP-2 HP 22-1/2" 36-3/8" O.D. 36-3/4" X 36-3/4" 1-1/2" 16 3 HP-5 HP 28-1/2" 36-3/8" O.D. 36-3/4" X 36-3/4" 1-1/2" 16 S-36 1 HP-2 HP 22-1/2" 42-3/8" O.D. 42-3/4" X 42-3/4" 1-1/2" 16 3 HP - 7-1/2 HP 28-1/2" 42-3/8" O.D. 42-3/4" X 42-3/4" 1-1/2" 16 S /2 HP-2 HP 22-1/2" 48-3/8" O.D. 48-3/4" X 48-3/4" 1-1/2" 16 3 HP - 7-1/2 HP 28-1/2" 48-3/8" O.D. 48-3/4" X 48-3/4" 1-1/2" HP 34-1/2" 48-3/8" O.D. 48-3/4" X 48-3/4" 1-1/2" 16 S /2 HP-5 HP 28-1/2" 54-3/8" O.D. 54-3/4" X 54-3/4" 1-1/2" /2 HP- 10 HP 34-1/2" 54-3/8" O.D. 54-3/4" X 54-3/4" 1-1/2" 16 S-54 2 HP-5 HP 28-1/2" 60-3/8" O.D. 60-3/4" X 60-3/4" 1-1/2" /2 HP- 10 HP 34-1/2" 60-3/8" O.D. 60-3/4" X 60-3/4" 1-1/2" 16 S-60 2 HP-5 HP 28-1/2" 66-3/8" O.D. 66-3/4" X 66-3/4" 1-1/2" /2 HP-10 HP 34-1/2" 66-3/8" O.D. 66-3/4" X 66-3/4" 1-1/2" 16 S-72 3 HP-5 HP 28-1/2" 78-3/8" O.D. 78-3/4" X 78-3/4" 1-1/2" /2 HP - 10 HP 34-1/2" 78-3/8" O.D. 78-3/4" X 78-3/4" 1-1/2" HP - 20 HP 40-1/2" 78-3/8" O.D. 78-3/4" X 78-3/4" 1-1/2" HP 46-1/2" 78-3/8" O.D. 78-3/4" X 78-3/4" 1-1/2" 16 S-84 5 HP 28-1/2" 90-3/8" O.D. 90-3/4" X 90-3/4" 1-1/2" /2 HP - 10 HP 34-1/2" 90-3/8" O.D. 90-3/4" X 90-3/4" 1-1/2" HP-20 HP 40-1/2" 90-3/8" O.D. 90-3/4" X 90-3/4" 1-1/2" HP 46" 90-3/8" O.D. 90-3/4" X 90-3/4" 1-1/2" 16 19

20 Direct Drive Jet Upblast Fans TRIANGLE ENGINEERING NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. JD Direct Drive fans are designed for heavy duty commercial/industrial application. Airfoil cast aluminum propellers (4 or 6 blade) are spark resistant. All welded motor base and supports assure long life and accurate drive alignment for maximum fan performance and minimum vibration. Direct Drive units are available in 24" - 60" diameters. Standard Features CURB BASE - Heavy gauge galvanized sheet steel base. All welded construction gives long maintenance-free service. AIRFOIL ALUMINUM BLADES - Four and six blade cast aluminum airfoil blades mounted on heavy duty cast aluminum fixed pitch hub for quiet, efficient operation. Taper lock bushings, between shaft and the fan blade hub used for positive mounting. Blade angle from 24 through 40 available for additional performance other than cataloged data. WIND BAND - Galvanized sheet steel with two formed reinforcing ribs. Supported by the curb base with galvanized steel brackets. It affords protection from weather and cross winds. THROAT - Galvanized steel inner throat is riveted to the deep venturi-type orifice for quieter, more efficient operation. EXTERNAL BRACING - Used on larger units to give extra rigidity and prevent sagging and vibration. DAMPER LIDS - Open automatically when fan is turned on, close automatically when fan stops. POSITIVE BUMPER STOPS - Adjustable neoprene tipped bumper stops assure immediate closing when fan is cut off, yet permit maximum air flow when open. DAMPER BEARINGS - Shutter lids turn on sintered bronze-oil bushings mounted on rust-proof rods for lifetime of resistance-free operation. Mounted outside of airstream. NEOPRENE BUMPER - Mounted around top of throat. It assures positive damper contact. Prevents freezing in cold weather. Dampens sound when closing. LIFTING LUGS - Provide for easier, surer and safer movement and mounting. INTERNAL BRACING - Rugged all-welded structure for extra support. RAIN CHANNEL - Directs rain to outside of fan and onto roof, thus keeping water out of building. 20

21 TRIANGLE ENGINEERING Performance JD Direct Drive Fans MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 4 Blades JD-24-DD 1/ JD-24-DD 3/ JD-24-DD 1-1/ JD-24-DD JD-30-DD 1/ JD-30-DD 3/ JD-30-DD JD-30-DD JD-30-DD JD-36-DD 3/ JD-36-DD JD-36-DD JD-36-DD JD-36-DD JD-36-DD 7-1/ MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 6 Blades JD-42-DD JD-42-DD JD-42-DD JD-42-DD JD-48-DD JD-48-DD JD-48-DD JD-48-DD JD-54-DD JD-54-DD 7-1/ JD-60-DD JD-60-DD AIR FLOW D DIMENSIONS MODEL A B C D C 3" CURB MAXIMUM A SQUARE - INSIDE Minimum Recom. Curb Height 6" JD JD JD JD JD JD JD

22 TRIANGLE ENGINEERING Belt Drive Jet Upblast Fans NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. V-Belt Drive units are available in 24" - 84" diameters, with motor in the air stream. The JBX design is our belt driven fan with the motor outside of the air stream. This fan features extended lube lines as standard. Motor cover and belt guard are optional. JBI Belt Drive fans are designed for heavy duty commercial/industrial application. Airfoil cast aluminum propellers (4 or 6 blade) are spark resistant. All welded motor base and supports assure long life and accurate drive alignment for maximum fan performance and minimum vibration. Standard Features CURB BASE - Heavy gauge galvanized sheet steel base. All welded construction gives long maintenance-free service. AIRFOIL ALUMINUM BLADES - Four and six blade cast aluminum airfoil blades mounted on heavy duty cast aluminum fixed pitch hub for quiet, efficient operation. Taper lock bushings, between shaft and the fan blade hub used for positive mounting. WIND BAND - Galvanized sheet steel with two formed reinforcing ribs. Supported by the curb base with galvanized steel brackets. It affords protection from weather and cross winds. EXTERNAL BRACING - Used on larger units to give extra rigidity and prevent sagging and vibration. DAMPER LIDS - Open automatically when fan is turned on, close automatically when fan stops. POSITIVE BUMPER STOPS - Adjustable neoprene tipped bumper stops assure immediate closing when fan is cut off, yet permit maximum air flow when open. DAMPER BEARINGS - Shutter lids turn on sintered bronze-oil bushings mounted on rustproof rods for lifetime of resistance-free operation. Mounted outside of airstream. NEOPRENE BUMPER - Mounted around top of throat. It assures positive damper contact. Prevents freezing in cold weather. Dampens sound when closing. LIFTING LUGS - Provide for easier, surer and safer movement and mounting. INTERNAL BRACING - Rugged all-welded structure for extra support. RAIN CHANNEL - Directs rain to outside of fan and onto roof, thus keeping water out of building. MOTOR AND MOTOR MOUNT - Belt drive fans are provided with adjustable motor mounts to allow for belt adjustment and heavy-duty selfaligning ball-bearing pillow blocks. 22

23 Dimensions Jet Upblast Fans TRIANGLE ENGINEERING B Dia. JBI (Belt Drive) Motor In Airstream AIR FLOW DIMENSIONS MODEL A B C D D C A Min. Recom. Curb Height 3" CURB MAXIMUM JBI JBI JBI JBI JBI JBl JBI JBI JBI B Dia. AIR FLOW JBX (Belt Drive) Motor out of Airstream DIMENSIONS MODEL A B C D D C 6" JBX JBX JBX JBX JBX JBX JBX JBX JBX A 23

24 Performance JBI/JBX Belt Drive Fans TRIANGLE ENGINEERING 4 BLADE CAST ALUMINUM PROPELLER MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP JBI-24-BD 1/ JBI-24-BD 1/ JBI-24-BD 1/ JBI-24-BD 3/ JBI-24-BD JBI-24-BD 1-1/ JBI-24-BD JBI-24-BD JBI-30-BD 1/ JBI-30-BD 3/ JBI-30-BD JBI-30-BD 1-1/ JBI-30-BD JBI-30-BD JBI-30-BD JBI-36-BD JBI-36-BD 1-1/ JBI-36-BD JBI-36-BD JBI-36-BD JBI-36-BD 7-1/

25 TRIANGLE ENGINEERING Performance JBI/JBX Belt Drive Fans 6 BLADE CAST ALUMINUM PROPELLER MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP JBI-42-BD 1-1/ JBI-42-BD JBI-42-BD JBI-42-BD JBI-42-BD 7-1/ JBI-42-BD JBI-48-BD 1-1/ JBI-48-BD JBI-48-BD JBI-48-BD JBI-48-BD 7-1/ JBI-48-BD JBI-54-BD JBI-54-BD JBI-54-BD JBI-54-BD 7-1/ JBI-54-BD JBI-60-BD JBI-60-BD JBI-60-BD JBI-60-BD 7-1/ JBI-60-BD JBI-72-BD JBI-72-BD JBI-72-BD 7-1/ JBI-72-BD JBI-72-BD JBI-72-BD JBI-84-BD JBI-84-BD 7-1/ JBI-84-BD JBI-84-BD JBI-84-BD JBI-84-BD

26 HHC Exhaust Supply Reversible HOODED FANS TRIANGLE ENGINEERING Hooded fans offer a variety of standard construction features for commercial and industrial applications where low noise and economy are required. Direct and V-belt drive units for exhaust, supply or reversible, are available in 24" through 84" diameters, with capacities up to 120,000 CFM. The following pages provide complete dimensional and performance information for Hooded Fans. airfoil design blades. Due to the smooth surfaces of the airfoil, undue turbulence does not occur. FINISH. Standard finish includes mill finish for hoods, polyester powder coat paint for the entire fan panel, fan support and motor brackets. MOTORS. Heavy duty, 60-cycle motors are designed for continuous duty fan requirements. Totally enclosed motors are standard. Options are available for specific requirements such as explosion-proof, mill and chemical, and textile service. V-BELT DRIVES. Standard V-belt drive components assure smooth operation. Motor and fan pulleys are cast sheaves provided with keyways and/or set screws. NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. STANDARD CONSTRUCTION FEATURES OPTIONAL ACCESSORIES: DISCONNECT SWITCHES LOUVERS ADJUSTABLE DRIVES ACCESS DOORS FILTERS BIRD SCREENS SPECIAL COATINGS SPECIAL CONSTRUCTION HOODS. Standard hoods are constructed of heavy galvanized steel with mill finish and shipped as a complete unit for either hinged or fixed installation in the field. Hoods are also available in aluminum. PROPELLERS. Hooded fans feature heavy duty cast aluminum propeller with 26

27 TRIANGLE ENGINEERING HHC Exhaust Supply Reversible HOODED FANS BELT DRIVE E E F D D A Square B Square 3 A Square B Square 3 END VIEW SUPPLY AIR FLOW EXHAUST AIR FLOW E DIRECT DRIVE E F D D A Square B Square 3 A Square B Square 3 END VIEW SUPPLY AIR FLOW EXHAUST AIR FLOW BLADE Inside Dimensions APPROX. DIA. A B D E F WT. (LBS.) / / /

28 Performance Direct Drive HHC TRIANGLE ENGINEERING CAST ALUMINUM PROPELLER MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 4 Blades 6 Blades HHC-24-DD 1/ HHC-24-DD 3/ HHC-24-DD HHC-24-DD 1-1/ HHC-24-DD HHC-30-DD 1/ HHC-30-DD 3/ HHC-30-DD HHC-30-DD HHC-30-DD HHC-36-DD 3/ HHC-36-DD HHC-36-DD HHC-36-DD HHC-36-DD HHC-42-DD HHC-42-DD HHC-42-DD HHC-42-DD 7-1/ HHC-42-DD HHC-48-DD HHC-48-DD HHC-48-DD HHC-48-DD 7-1/ HHC-48-DD HHC-48-DD HHC-54-DD HHC-54-DD 7-1/ HHC-54-DD HHC-60-DD HHC-60-DD 7-1/ HHC-60-DD HHC-60-DD

29 TRIANGLE ENGINEERING Performance HHC Belt Drive MODEL MTR. TIP PEAK CFM NO. HP RPM SPEED BHP.00"SP.10"SP.125"SP.25"SP.375"SP.50"SP.75"SP 1.00"SP 6 Blade Cast Aluminum Propeller 4 Blade Cast Aluminum Propeller HHC-24-BD 1/ HHC-24-BD 3/ HHC-24-BD HHC-24-BD 1-1/ HHC-24-BD HHC-24-BD HHC-30-BD 1/ HHC-30-BD 3/ HHC-30-BD HHC-30-BD 1-1/ HHC-30-BD HHC-30-BD HHC-30-BD HHC-36-BD HHC-36-BD 1-1/ HHC-36-BD HHC-36-BD HHC-36-BD HHC-36-BD 7-1/ HHC-42-BD 1-1/ HHC-42-BD HHC-42-BD HHC-42-BD HHC-42-BD 7-1/ HHC-42-BD HHC-48-BD HHC-48-BD HHC-48-BD HHC-48-BD HHC-48-BD 7-1/ HHC-48-BD HHC-54-BD HHC-54-BD HHC-54-BD HHC-54-BD 7-1/ HHC-54-BD HHC-60-BD HHC-60-BD HHC-60-BD HHC-60-BD 7-1/ HHC-60-BD HHC-60-BD

30 TP High Velocity Fans Personnel & Product Coolers TRIANGLE ENGINEERING and endless other applications. The TP Fans produce air circulation that will keep an area from becoming stagnant with hot or polluted air. Construction The all-steel, all-welded construction with removable, heavy-gauge, expanded metal safety guards insures many years of dependable, trouble-free operation. Non-overloading, spark-resistant cast aluminum airfoil blades, pitch-matched for maximum air delivery, at the lowest horsepower and highest efficiency offer the ultimate in air delivery and smooth, high-velocity air penetration. Standard finish is gray Polyester Powder Coat paint. Mounting bushing with 2" female pipe thread permits quick mounting to wall, ceiling or pedestal base Options NON-OVERLOADING AIRFOIL Cast Aluminum Fan Blades are a special feature to insure high operating efficiencies. Conventional flat blades cause excessive air turbulence which results in motor overloads and poor acoustic performance. TP-B pedestal base OSHA guards available for application below 7 height Explosion proof motors available Applications TP High Velocity Fans are easily installed units that offer economical, efficient air cooling for almost any kind of indoor/outdoor location. They are ideal for manufacturing areas, furnace rooms, welding booths, storage and drying rooms, warehouses, spot-cooling of equipment, stockyards, barns, cotton gins, saw mills, drilling rigs, live poultry in trucks 30

31 TRIANGLE ENGINEERING TP High Velocity Fans AIR PROJECTION APPROX. VELOCITY 300 FPM* SHIPPING SIZE HP RPM CFM AT FAN FPM AT NO.FT WEIGHT TP-24-S 1/ / / TP-30-S 1/ / TP-36-S 3/ TP-42-S TEFC Motor standard Explosion Proof Motor optional. * 300 FPM is approx. 3.5 mph Model TP-S Model TP-B Standard mounting - 2" internal pipe thread. Pedestal Base extra. 42" to center of fan DIMENSIONS A - 4" Over blade size B - 9-1/2" Plus outside part of motor 31

32 Rooftop Accessories TRIANGLE ENGINEERING Windband / Stack Cap WIND BAND - Galvanized sheet steel with two formed reinforcing ribs. Supported by the galvanized steel brackets. It affords protection from weather and cross winds. THROAT - Galvanized steel inner throat is welded to angle ring. EXTERNAL BRACING - Used on larger units to give extra rigidity and prevent sagging and vibration. DAMPER LIDS - Open automatically when fan is turned on, close automatically when fan stops. POSITIVE BUMPER STOPS - Adjustable neoprene tipped bumper stops assure immediate closing when fan is cut off, yet permit maximum air flow when open. DAMPER BEARINGS - Shutter lids turn on sintered bronze-oil bushings mounted on rust-proof rods for lifetime of resistance-free operation. Mounted outside of airstream. NEOPRENE BUMPER - Mounted around top of throat. It assures positive damper contact. Prevents freezing in cold weather. Dampens sound when closing. Model I.D. O.D. H WBSC 24 24" 33" 29" WBSC 28 28" 33" 31" WBSC 30 30" 39" 32" WBSC 36 36" 45" 32" WBSC 42 42" 51" 35" WBSC 48 48" 57" 38" WBSC 54 54" 63" 41" WBSC 60 60" 69" 44" NOTE: Standard Angle Ring 2" x 3/16" No holes drilled. (24" Dia. & smaller 1-1/2" x 3/16") Changed to customer specifications by request. Rain Cap Available in sizes 6" - 36" Flanged caps fit over exhaust tubing for form fit Installs with basic hand tools Brass bushing and stainless steel pivot to prevent rust Adjustable counterbalance for efficient flow Powder coat standard gray or to match your application Available in carbon steel, 304 or 316 stainless steel Specifications subject to change without notice.

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

Type VA Vanax Fans. Models VA, VAD, & VAB

Type VA Vanax Fans. Models VA, VAD, & VAB Type VA Vanax Fans Models VA, VAD, & VAB Type VA Direct Drive Model VA Sizes 6 through 10 207 to 1,811 CFM Static Pressure to 1-1/2 Type VAB Belt Drive Model VAB Sizes 12 through 48 1,004 to 47,176 CFM

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS UPBLAST PROPELLER FANS Model LUBK SECTION 16 MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS Application Model LUBK is a high capacity roof mounted exhauster rated from 3,560 to 42,000 CFM. It

More information

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories IRECT RIVE TUBEAXIAL FANS Model LIA Model LIA IRECT RIVE TUBEAXIAL FANS SECTION 12 Application Carnes Company tubeaxial fans offer one of the widest ranges of sizes, horsepower and performance in the industry.

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems Medium Pressure Axial Fans Model TBI-FS Levels 3, 4 & 5 with Fabricated Steel Propeller Belt Drive Inline or Roof Mounted Upblast Clean Air or Fume Exhaust High Temperature Process Exhaust Emergency Smoke

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements. CWBA Sizes 12 to 20 711 to 5709 CFM Static Pressure to 2 AMCA Licensed Ratings for Sound and Air CWDA Sizes 06 to 20 133 to 4942 CFM Static Pressure to 1 AMCA Licensed Ratings for Sound and Air Safety

More information

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type. January 2008 FADE0108 Fantech, Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Centrifugal Filtered Supply Fans

Centrifugal Filtered Supply Fans Centrifugal Filtered Supply Fans Model KSF Application/Construction Options/Accessories Construction Features Performance/Dimensions NFPA96 Installation/Common TXB Series Restaurant Exhauster Additional

More information

FIXED PITCH PROPELLER FANS

FIXED PITCH PROPELLER FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

TU-WAY ROOF VENTILATORS

TU-WAY ROOF VENTILATORS BULLETIN 615 December 2000 TU-WAY ROOF VENTILATORS Tu-WAY Roof Ventilators Aerovent has provided quality air moving and ventilation equipment for over sixty-five years and is a recognized leader in this

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information

Types RE & RES- Recirculating Roof Ventilators

Types RE & RES- Recirculating Roof Ventilators Types RE & RES- Recirculating Roof Ventilators Contents Type RE and RES PRVs General Information Page 3 Special performance requirements American Coolair makes axial, propeller and centrifugal type ventilation

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

TRIANGLE FANS GENERAL CATALOG

TRIANGLE FANS GENERAL CATALOG TM TRIANGLE ENGINEERING OF ARKANSAS, INC. TRIANGLE FANS GENERAL CATALOG Specifications subject to change without notice. Industrial and all-purpose FANS Heat Busters, Belt Drive...2 Mister Kits...2 Portable

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof

More information

PRODUCT FEATURES. BEARING LIFE All bearings are designed for L50 life of 200,000 hours.

PRODUCT FEATURES. BEARING LIFE All bearings are designed for L50 life of 200,000 hours. PRODUCT FEATURES These fans must be installed in a manner which insures that the exhausted air and the surrounding environment are always free of flammable gases, vapors, or liquids, combustible dusts

More information

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements. mericraft Manufacturing Company Inc. has been manufacturing quality industrial fans and ventilation products since 1946. Our 50+ years of proven experience, strong national reputation and excellent customer

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall Roof Downblast Models LPD & RED LPD Applications/Construction LPD Performance/Dimensions RED Applications/Construction RED Performance/Dimensions

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24 72 Diameter Bulletin PF-1410 July 2003 A Fläkt Woods Company PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003 Fläkt Woods Group Creative Air Fläkt Woods was created by bringing together several of the worlds leading players

More information

Propeller Upblast Roof Fans

Propeller Upblast Roof Fans Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

UPBLAST AXIAL ROOF VENTILATORS

UPBLAST AXIAL ROOF VENTILATORS BULLETIN 616 July 1997 UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile of Aerovent s upblast roof ventilators.

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio Vaneaxial Fans Series 25 Series 53 Series 53C Series 54 Series 55 BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 February 2008 Index Model Code Explanation...Page

More information

HARTZELL. Power Roof Ventilators. Hartzell Fan, Inc., Piqua, Ohio

HARTZELL. Power Roof Ventilators. Hartzell Fan, Inc., Piqua, Ohio Power Roof Ventilators Upblast Hooded Recirculating Smoke Ventilators Series 61 & 63 Series 15, 16 & 17 Series 26 & 27 Series 69H Series 69 & 69S Series 71J, 73J & 75J BUILT WITH HONOR HARTZELL FAN, INC

More information

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS BULLETIN 420 November 2000 MARINE DUTY TUBEAXIAL & VANEAXIAL FANS Type MD Direct Drive Model MDTM, MDVM & MDVH Marine Duty Tubeaxial and Vaneaxial Fans Aerovent s Marine Duty Fans feature medium and high

More information

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual Direct Drive Sidewall Propeller Fans (Exhaust and Supply) READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is

More information

Good Enough Never Is. Plug Fan SERIES 12

Good Enough Never Is. Plug Fan SERIES 12 Plug Fan SERIES 12 Good Enough Never Is The Hartzell Difference Combine Hartzell QUALITY with your PRODUCT for a BETTER CHOICE for your customers! GOOD ENOUGH NEVER IS. Hartzell Air Movement is the industrial

More information

TORIN by: AIRDEX Index Page No.

TORIN by: AIRDEX Index Page No. Index Page No. N Series Fans 2 Bladed, Heavy Duty...1 N Series Fans 3 Bladed, Free Air...2-3 N Series Fans 4 Bladed, Heavy Duty...4-5 Universal Hubs...6 One Piece Fan O Series 4 & 5 Bladed...7 One Piece

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX510-A October 2009 ADJUSTABLE PITCH PROPELLER FANS TYPE TCWPX TCWPX Adjustable Pitch Propeller Fans Sizes 24" 48" Direct Drive Belt Driven Heavy-Duty Construction Twin

More information

CONSTRUCTION FEATURES

CONSTRUCTION FEATURES CONSTRUCTION FEATURES Model LQ ventilators are direct drive propeller roof fans designed to deliver large volumes of air. Nine sizes are available from 10" to 36" diameter. Capacities range from 135 to

More information

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS Direct Drive & Belt Driven Model VJ / VJBD CATALOG 476 June 2015 Vaneaxial Fans Model VJ / VJBD Type "J" The heart

More information