1 TROX Prisliste 2019 Regulatorer K5-00

2 K1 - ARMATURER, RISTE Ceiling swirl diffusers AIRNAMIC...7 VDW...8 TDV-SilentAIR...9 RFD...10 FD...11 TDF-SilentAIR...12 VD...13 VDL...14 FDE...16 Design ceiling swirl diffusers XARTO...17 ADD...18 Ceiling swirl diffusers with perforated face plate DCS...19 Ceiling diffusers VDR...20 DLQ...21 DLQL...22 DLQ-AK...24 DLK-Fb...25 Slot diffusers for ceiling installation VSD VSD VSD35-TZ...29 VSD Slot diffusers for wall installation VSD50-1-LT...35 VSD35-3-AZ...36 Ventilation grilles for installation into walls, sills or rectangular ducts X-GRILLE Cover...37 X-GRILLE Basic...39 SL...43 TR...47 TRS...50 TRS-K...53 Ventilation grilles for floor installation ARR...54 Ventilation grilles for installation into circular ducts TRS-R...55 Volume flow rate balancing AGW...56 DGW...57 ASW...58 Displacement flow diffuser for Installation on a wall QLE...59 QLF...60 QLV...62 Displacement flow diffuser for wall installation QLW-AZ...64 Freestanding displacement flow diffuser QLV Displacement diffusers QSH...67 Impulse diffusers ISH...68 Jet nozzles TJN...69 Jet nozzles DUK...70 Disc valves LVS...72 Z-LVS...73 Floor diffusers FBA...74 FBK...75 Staircase swirl diffusers SD...76 Control units LON-WA TDC...77 K2 - KØLEBAFLER Units for suspended ceilings DID DID300B...80 DID DID DID600B-L...86 DID DID DID-R...91 Units for bulkheads DID-E...92 Freely suspended units SMART BEAM...93 IDH...94 Wall and under sill units QLI...95 Under sill units IDB...96 Under floor units BID...97 Passive chilled beams PKV...98 Control equipment for air-water systems LWS control equipment Under sill units FSL-B-ZAB SCHOOLAIR-B Vertical units FSL-V-ZAB SCHOOLAIR-V Ceiling units SCHOOLAIR-D Control systems X-AIRCONTROL Connecting hoses FS...108

3 K3 - SPJÆLD, RISTE, LYDDÆMPERE Multileaf dampers JZ Multileaf dampers JZ-LL External weather louvres WG WGK WGF WG-JZ WG-KUL Non-return dampers UL KUL ARK Pressure relief dampers ARK Shut-off dampers NAK Doors ST BS Splitter sound attenuators MSA XSA MSA, XSA MKA XKA RKA Circular silencers CA CB CS CF CAK K4 - BRANDSPJÆLD Fire dampers FK-EU FKA-EU FKS-EU FKR-EU FKRS-EU KU-K KA-EU FV-EU FVZ-K Smoke protection dampers JZ-RS Duct smoke detectors RM-O-VS-D RM-O-3-D Smoke control dampers EK-EU TROXNETCOM LON Modules TROXNETCOM AS-i Master and display units Controllers and repeaters Switching power supply units Power supply units Pre-configured switch boxes Modules AS-i installation Adjustment and addressing devices Decentralised operating and monitoring systems TNC-EASYCONTROL TNC-LINKBOX Modbus/BACnet modules K5 - REGULATORER VARYCONTROL LVC TVR TVJ TVT TZ-Silenzio TA-Silenzio TVZ TVA TVM TVRK Secondary silencers for VAV terminal units TS TX Control components for VAV terminal units RETROFIT RC Adjustment devices for VAV terminal units Adjustment devices Room control - X-AIRCONTROL X-AIR-ZMAS X-AIR-ZMO X-AIR-CP X-AIR-SENS CONSTANTFLOW RN EN VFC VFL EXCONTROL RN-Ex EN-Ex Actuators for CAV controllers Retrofit kits Shut-off dampers AK AKK Flow adjustment dampers VFR Volume flow rate measuring units VMR VMRK VME Heat exchanger WT WL EL K6 - EASYLAB - LABCONTROL Varycontrol TVLK BE-SEG BE-LCD TVLK...301

4 VMLK TVRK VMRK TVR VMR TVJ TVT VME TZ-Silenzio TA-Silenzio TVZ TVA TAM FSE Accessories Accessories for LABCONTROL Monitoring system FMS Sensor systems Differential pressure transducer Configuration software EasyConnect VAV terminal units TVR-Ex Shut-off dampers AK-Ex K7 - FILTRERING Standard cell frames SCF Filter wall SIF Mounting frames MF Mounting plates MP Universal casing UCA Ducted particulate filters KSF Ducted particulate filters for critical requirements KSFS Spigot KSFSSP Duct casings for particulate filters DCA Ceiling mounted particulate filters TFC Wall mounted particulate filter TFW Particulate filter modules for ceilings TFM Pharmaceutical clean room terminal filters TFP Pressure measuring devices MD Automatic roll filter media FMC Roll media FMR Cut-to- pads FMP Z-line filters ZL Pocket filters made of non-woven chemical fibres PFC Pocket filters made of non-woven synthetic fibres PFS Pocket filters made of NanoWave medium PFN Pocket filters made of non-woven glass fibres PFG Filter inserts MFI Filter elements MFE Filter cells MFC Filter panels MFP Filter cartridges MFCA Filter panels for clean room technology MFPCR Filter panels with hood FHD Filter inserts ACFI Filter cartridges ACFC Filter cells ACF K8- X-CUBE X-CUBE X-CUBE compact XCC-RO XCC-ROM-HM XCC-HD XCC-HM XCC-HCM XCC-EHD XCC-CB XCC-CD XCC-S XCC-LON XCC-CPC XCC-V XCC-P XCC-LE Attachment Detail VARYCONTROL Control components Calculation example Splitter sound attenuators...431

5 Prisliste 2019 DKK brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL LVC (ød) For low airflow velocities and low duct pressures LVC / 160 / BC0 / E 0 / LVC / 160 / Easy Type LVC VAV terminal unit [mm] Attachments (control component) Easy Easy controller BC0 Compact controller Operating mode E Single M Master S Slave F Constant value Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m 3 /h or l/s] min - max for factory setting Type LVC VARYCONTROL control components Easy BC For information on the Easy or Compact control components see the Control Units catalogue, K

6 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVR Prisliste 2019 DKK brutto ekskl. moms (ød) For the most diverse applications regarding standard volume flow rate ranges TVR D... FL / 160 / G2 / B1B / E 0 / / NO TVR D / 200 / D2 / Easy Type TVR VAV terminal unit Acoustic cladding D With acoustic cladding Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey A2 Stainless steel Flange FL Both ends (not for TVR-D-P1) [mm] Accessories D2 Lip seals on both ends G2 Matching flanges for both ends Attachments (control component) Example Easy Compact controller BC0 Compact controller B13 Universal controller Operating mode E Single M Master S Slave F Constant value A Differential pressure control - extract air Z Differential pressure control - supply air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating modes A, Z) Damper blade position Only with spring return actuators NO Power off to open NC Power off to close Type TVR Eas y BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B13 B1B XC3 BB3 BBB BP3 BG3 BGB XD1 XD Easy 2 Compact, dynamic 3 Compact, static 4 Universal, dynamic 5 Universal, static 228

7 Prisliste 2019 DKK brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVR Type TVR TVR- - TVR- -A2- D P1 FL D2 G2 A2 FL G Surcharge Restricted availability of equipment combinations: -P1, -A2 cannot be combined with Easy, Compact or Universal (dynamic) control components -FL, -G2 cannot be combined with Easy control components -P1, -A2 cannot be combined with -D and -FL 229

8 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVJ Prisliste 2019 DKK brutto ekskl. moms (H) (B) For normal and high volume flow rate ranges TVJ D P1 / / B1B / E 0 / / NO TVJ D / / Easy Type TVJ VAV terminal unit Acoustic cladding D With acoustic cladding Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey [mm] B H Attachments (control component) Example Easy Easy controller BC0 Compact controller B13 Universal controller Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating modes A, Z) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE Operating mode E Single M Master S Slave F Constant value A Differential pressure control - extract air Z Differential pressure control - supply air 230

9 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVJ B H Type TVJ VARYCONTROL control components Eas y BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B13 B1B XC3 BB3 BBB BP3 BG3 BGB XD1 XD Easy 2 Compact dynamic 3 Compact static 4 Universal dynamic 5 Universal static 259

10 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVJ Prisliste 2019 DKK brutto ekskl. moms Type TVJ VARYCONTROL control components B H D P Surcharge Type TX Secondary silencer Sound attenuator B H TX Restricted availability of equipment combinations: -P1 cannot be combined with Easy, Compact or Universal (dynamic/static) control components 260

11 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVT (H) (B) For normal and high volume flow rate ranges and air-tight shut-off TVT D P1 / / B1B / E 0 / / NO TVT D / / Easy Type TVT VAV terminal unit Acoustic cladding D With acoustic cladding Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey [mm] B H Attachments (control component) Example Easy Easy controller BC0 Compact controller B11 Universal controller Operating mode E Single M Master S Slave F Constant value A Differential pressure control - extract air Z Differential pressure control - supply air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating modes A, Z) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE 261

12 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVT Prisliste 2019 DKK brutto ekskl. moms Type TVT B H Easy BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B11 B1B XC3 BB1 BBB BP1 BG1 BGB XD Easy 2 Compact, dynamic 3 Compact, static 4 Universal, dynamic 5 Universal, static 262

13 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVT Serie TVT VARYCONTROL control components B H D P Surcharge Type TX Secondary silencer Sound attenuator B H TX Restricted availability of equipment combinations: -P1 cannot be combined with Easy, Compact or Universal (dynamic/static) control components 263

14 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TZ-Silenzio Prisliste 2019 DKK brutto ekskl. moms H B L For supply air systems with demanding acoustic requirements and low airflow velocities TZ Silenzio D / 200 / B1B / E 0 / / NO TZ Silenzio D / 200 / Easy Type TZ-Silenzio air Acoustic cladding D With acoustic cladding VAV terminal unit, supply Attachments (control component) Example Easy Easy controller BC0 Compact controller B13 Universal controller Operating mode E Single M Master S Slave F Constant value Z Differential pressure control - supply air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating mode A) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE Type TZ-Silenzio VARYCONTROL control components Eas y BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B13 B1B XC3 BB3 BBB BP3 BG3 BGB XD1 XD Easy 2 Compact dynamic 3 Compact static 4 Universal dynamic 5 Universal static Type TZ-Silenzio D Surcharge Secondary silencer TS

15 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TA-Silenzio H B L For extract air systems with demanding acoustic requirements and low airflow velocities TA Silenzio D / 200 / B1B / E 0 / / NO TA Silenzio D / 200 / Easy Type TA-Silenzio air Acoustic cladding D With acoustic cladding VAV terminal unit, extract Attachments (control component) Example Easy Easy controller BC0 Compact controller B13 Universal controller Operating mode E Single M Master S Slave F Constant value A Differential pressure control - extract air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating mode A) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE Type TA-Silenzio VARYCONTROL control components Eas y BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B13 B1B XC3 BB3 BBB BP3 BG3 BGB XD1 XD Easy 2 Compact dynamic 3 Compact static 4 Universal dynamic 5 Universal static Type TA-Silenzio D Surcharge Secondary silencer TS

16 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVZ Prisliste 2019 DKK brutto ekskl. moms (ød) For supply air systems with demanding acoustic requirements TVZ D / 160 / D1 / B1B / E 0 / / NO TVZ D / 160 / D1 / Easy Type TVZ VAV terminal unit, supply air Acoustic cladding D With acoustic cladding [mm] Accessories D1 Lip seal Type TVZ VARYCONTROL control components Attachments (control component) Example Easy Easy controller BC0 Compact controller B13 Universal controller Operating mode E Single M Master S Slave F Constant value Z Differential pressure control - supply air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating mode A) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE Eas y BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B13 B1B XC3 BB3 BBB BP3 BPG BG3 BGB XD Easy 2 Compact dynamic 3 Compact static 4 Universal dynamic 5 Universal static Type TVZ D D Surcharge Secondary silencer TS

17 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVA (ød) For extract air systems with demanding acoustic requirements TVA D / 160 / D1 / B1B / E 0 / / NO TVA D / 160 / D1 / Easy Type TVA VAV terminal unit, extract air Acoustic cladding D With acoustic cladding [mm] Accessories D1 Lip seal Type TVA VARYCONTROL control components Attachments (control component) Example Easy Easy controller BC0 Compact controller B13 Universal controller Operating mode E Single M Master S Slave F Constant value A Differential pressure control - extract air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating mode A) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE Eas y BC0 BL0 BM0 BM0 -J6 XB0 LN0 LK0 SA0 SC0 B13 B1B XC3 BB3 BBB BP3 BPG BG3 BGB XD Easy 2 Compact dynamic 3 Compact static 4 Universal dynamic 5 Universal static Type TVA D D Surcharge Secondary silencer TS

18 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVM Prisliste 2019 DKK brutto ekskl. moms (ød) (ød) For dual duct systems TVM S D / 160 / D2 / B13 / E 0 / / Type TVM Dual duct terminal unit Spigot arrangement No entry: 90 S 60 (up to nominal 200) Acoustic cladding No entry: without D With acoustic cladding [mm] Attachments (control component) Example BC0 Compact controller B13 Universal controller Operating mode E Single M Master F Constant value Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s] warm, min - warm, max / cold, min - cold, max for factory setting Accessories No entry: without D2 Lip seal Type TVM VARYCONTROL control components 1 2 BF0 XG0 BM0 BM0-J6 B Grundpreis D D2 Secondary silencer VARYCONTROL control components TS Compact dynamic 2 Universal dynamic For information on the Compact or Universal (dynamic) control components see the Control Units catalogue, K

19 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS VARYCONTROL TVRK (ød) For contaminated air TVRK FL / 160 / GK / BB3 / E 2 / / NO Type TVRK VAV terminal unit, plastic Flange FL Flanges on both ends [mm] Accessories GK Matching flanges for both ends Attachments (control component) Example BB3 Universal controller with static differential pressure transducer Operating mode E Single M Master S Slave F Constant value Z Differential pressure control - supply air A Differential pressure control - extract air Signal voltage range For the actual and setpoint value signals V DC V DC Volume flow rates [m³/h or l/s], differential pressure [Pa] min - max for factory setting p min for factory setting (operating modes A, Z) Damper blade position Only with spring return actuators NO Power off to OPEN NC Power off to CLOSE Type TVRK VARYCONTROL control components 1 2 SA0 SC0 BB3 BBB BP3 BPG BG3 BGB XD1 XD Compact static 2 Universal static FL GK Surcharge 269

20 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Secondary silencers for VAV terminal units TS Prisliste 2019 DKK brutto ekskl. moms For the reduction of air-regenerated noise of air terminal units Type TVZ, TVA, TZ-Silenzio, TA-Silenzio or TVM TS / 200 Type TS Secondary silencer 125, 160, 200, 250, 315, 400 Type TS TS

21 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Secondary silencers for VAV terminal units TX (H) (B) For the reduction of air-regenerated noise of air terminal units Type TVJ, TVT or EN TX / Type TX Secondary silencer [mm] B H TX Secondary silencer B H TX B H TX

22 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Control components for VAV terminal units RETROFIT Prisliste 2019 DKK brutto ekskl. moms Rapid replacement without interruption of system operation EasySet / 1 Parts kit EasySet CompactSet UniversalSet Accessories Special adapters are available for units with 8 x 8 mm square shafts or with short circular shafts 1 For EasySet and CompactSet 2 For UniversalSet Type RETROFIT 1 2 EasySet CompactSet UniversalSet Surcharge 272

23 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Control components for VAV terminal units RC For the individual temperature control in rooms RC / B1 Type RC Type B1 B2 B3 M1 M2 Room temperature controller CR24-B1 CR24-B2 CR24-B3 ETN-24-VAV-277V-P Remote control for M1 Type RC B B B M M

24 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Adjustment devices for VAV terminal units Adjustment devices Prisliste 2019 DKK brutto ekskl. moms For service and commissioning AT VAV B Type AT-VAV Variants B G S Adjustment devices for VAV terminal units ZTH-EU for TROX/Belimo volume flow controllers for TROX/Gruner volume flow controllers AST20 for Siemens volume flow controllers Type Adjustment devices B G S

25 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Room control - X-AIRCONTROL X-AIR-ZMAS Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIR-ZMAS Type X-AIR-ZMAS X-AIRCONTROL zone master module Type X-AIR-ZMAS X-AIR-ZMAS Pris på forespørgsel 275

26 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Room control - X-AIRCONTROL X-AIR-ZMO Prisliste 2019 DKK brutto ekskl. moms Zone modules for single room control X-AIR-ZMO MOD Type X-AIR-ZMO X-AIRCONTROL zone module Variant MOD MP ANA Zone module with Modbus RTU interface Zone module with MP bus interface Zone module with analogue interface Type X-AIR-ZMO MOD MP ANA Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel 276

27 Prisliste DKK 2019 brutto ekskl. moms VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Room control - X-AIRCONTROL X-AIR-CP Control panels for X-AIRCONTROL zone modules X-AIR-CP 2T Type X-AIR-CP X-AIRCONTROL control panel Variant 2T TS Control panel with temperature sensor and 2" touch screen Control panel with temperature sensor and setpoint value adjuster Type X-AIR-CP 2T Pris på forespørgsel TS Pris på forespørgsel 277

28 VARIABLE VOLUME FLOW CONTROL VAV TERMINAL UNITS Room control - X-AIRCONTROL X-SENS Prisliste 2019 DKK brutto ekskl. moms Sensors for X-AIRCONTROL zone modules and other equipment X-SENS VOC Type X-SENS Sensor Variant TEMP-RH-EXH Combined temperature and humidity sensor for extract air TEMP-PT1000 Duct temperature sensor (PT1000) VOC Air quality sensor (VOC) CO2-RH Combined CO 2 and humidity sensor DEWPT Dew point monitor PIR-SM 180 motion detector PIR-FM 360 motion detector SPLITTER Four-way splitter for the connection of four sensors or control panels (Modbus) Type X-SENS Variante TEMP-RH-EXH TEMP-RH-SUP TEMP-PT1000 VOC CO2-RH DEWPT PIR-SM PIR-FM SPLITTER Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Pris på forespørgsel Price 278

29 Prisliste DKK 2019 brutto ekskl. moms CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS CONSTANTFLOW RN (ød) For the precise control of constant volume flow rates RN D P1 FL / 160 / G2 / B50 / Type RN Volume flow controller Acoustic cladding D With acoustic cladding Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey A2 Stainless steel Flange FL Flanges on both ends [mm] 80, 100, 125, 160, 200, 250, 315, 400 Accessories D2 Lip seals on both ends G2 Matching flanges for both ends Actuator No entry: without For example B50 24 V AC/DC, 3-point B52 24 V AC/DC, 3-point, with auxiliary switch B70 24 V AC/DC, modulating 2-10 V DC Volume flow rates [m 3 /h or l/s] only actuators min - max for factory setting Type RN RN- - RN- -A2- RN- - RN D P1 FL D2 G2 A2 FL G2 B50 B52 B60 B62 B70 B Surcharge For detailed information on Min/Max actuators and modulating actuators see the Control Units catalogue, K5-2.2 Restrictions for nominal 80: - Not with flange/matching flange FL/G2 - Stainless steel construction A2 without lip seal D2-279

30 CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS CONSTANTFLOW RN Prisliste 2019 DKK brutto ekskl. moms RN-S P1 / 100 / D2 Type RN-S Volume flow controller [mm] 80, 100, 125 Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey A2 Stainless steel Accessories D2 Lip seals on both ends Variant RN-S RN-S P1 A2 D Base price Surcharge NOTE Only for nominal 80 - Stainless steel construction A2 without lip seal D2 280

31 Prisliste DKK 2019 brutto ekskl. moms CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS CONSTANTFLOW EN (H) (B) For the precise control of normal and high constant volume flows EN D P1 / / B50 / Type EN Volume flow controller Acoustic cladding D With acoustic cladding Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey [mm] B H Actuator No entry: without For example B50 24 V AC/DC, 3-point B52 24 V AC/DC, 3-point, with auxiliary switch B70 24 V AC/DC, modulating 2-10 V DC Volume flow rates [m 3 /h or l/s] only actuators min - max for factory setting Type EN B H EN D P1 B50 B52 B60 B62 B70 B Base price Surcharge Secondary silencer B H TX Price For detailed information on Min/Max actuators and modulating actuators see the Control Units catalogue, K

32 CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS CONSTANTFLOW VFC Prisliste 2019 DKK brutto ekskl. moms (ød) For low airflow velocities VFC / 100 / E01 Type VFC Volume flow controller Type VFC VFC E01 E02 E03 M01 M Base price Surcharge [mm] 80, 100, 125, 160, 200, 250 Actuator No entry: manual operation For example E01 24 V AC/DC, 3-point, potentiometer E03 24 V AC/DC, modulating 2-10 V DC, potentiometer M01 24 V AC/DC, 3-point, mechanical stops 282

33 Prisliste DKK 2019 brutto ekskl. moms CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS CONSTANTFLOW VFL (ød) Volume flow limiter for insertion into ducting VFL / 100 Type VFL Volume flow limiter [mm] 80, 100, 125, 150, 160, 200, 250 Type VFL Surcharge for different reference volume flow rates EUR 9/unit Only when calling off at least 50 units with the same nominal and reference volume flow rate 283

34 CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS EXCONTROL RN-Ex Prisliste 2019 DKK brutto ekskl. moms (ød) RN Ex 160 For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) RN Ex D P1 / 160 / D2 Type RN-Ex Volume flow controller for potentially explosive atmospheres [mm] 80, 100, 125, 160, 200, 250, 315, 400 Acoustic cladding D With acoustic cladding Accessories D2 Lip seals on both ends Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey A2 Stainless steel Type RN-Ex RN-Ex D P1 A2 D Restrictions for nominal 80: Stainless steel construction A2 without lip seal D2 Surcharge 284

35 Prisliste DKK 2019 brutto ekskl. moms CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS EXCONTROL EN-Ex (H) (B) For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) EN Ex D P1 / Type EN-Ex Volume flow controller for potentially explosive atmospheres Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey Acoustic cladding D With acoustic cladding [mm] B H Type EN-Ex B H EN-Ex D P Base price Surcharge Secondary silencer B H TX Price 285

36 CONSTANT VOLUME FLOW CONTROL CAV CONTROLLERS Actuators for CAV controllers Retrofit kits Prisliste 2019 DKK brutto ekskl. moms For variable volume flows or min / max switching in room air conditioning systems NR-VAV E01 Type NR-VAV Retrofit kit Variant For Types EN and RN B50 Retrofit actuator for min/max switching, identical to attachment B50 B60 Retrofit actuator for min/max switching, identical to attachment B60 B70 Retrofit actuator for variable adjustment, identical to attachment B70 S2 Retrofit auxiliary switch, identical to attachment B*2 ENMAT Retrofit installation accessories for EN RNMAT Retrofit installation accessories for RN E01 E02 E03 M01 M02 For Types VFC and VFR Retrofit actuator for min/max switching, identical to attachment E01 Retrofit actuator for min/max switching, identical to attachment E02 Retrofit actuator for variable adjustment, identical to attachment E03 Retrofit actuator for min/max switching, identical to attachment M01 Retrofit actuator for min/max switching, identical to attachment M02 Type Retrofit kits for Types EN and RN B B B S ENMAT RNMAT Retrofit kit for Types VFC and VFR E E E M M

37 Prisliste DKK 2019 brutto ekskl. moms SHUT-OFF AND RESTRICTION Shut-off damper AK (ød) For low-leakage shut-off AK P1 FL / 160 / G2 / BP0 / NO Type AK Shut-off damper Material No entry: galvanised sheet steel P1 Powder-coated, silver grey (RAL 7001) A2 Stainless steel Construction FL Flanges on both ends [mm] 100, 125, 160, 200, 250, 315, 400 Actuator No entry: manual operation For example B20 24 V AC/DC, modulating 2-10 V DC B30 24 V AC/DC, 3-point B32 24 V AC/DC, 3-point, with auxiliary switch TN0 Pneumatic bar Damper blade position Only for spring return actuators and pneumatic actuators NO Pressure off/power off to OPEN NC Power off/pressure off to close Accessories D2 Lip seals on both ends G2 Matching flanges for both ends Type AK AK- - AK- -A2- AK- - AK P1 FL D2 G2 A2 FL G2 B20 B30 B32 B40 B42 BP0 BP2 BR0 BR2 TN Base price Surcharge For information on Open/Close actuators see the Control Units catalogue, K

38 SHUT-OFF AND RESTRICTION Shut-off damper AKK Prisliste 2019 DKK brutto ekskl. moms (ød) For contaminated air AKK FL / 160 / GK / BP0 / NO Type AKK Shut-off damper, plastic Flange FL Flanges on both ends [mm] 125, 160, 200, 250, 315, 400 Accessories GK Matching flanges for both ends Actuator No entry: manual operation For example B20 24 V AC/DC, modulating 2-10 V DC B30 24 V AC/DC, 3-point B32 24 V AC/DC, 3-point, with auxiliary switch TN0 Pneumatic bar Damper blade position Only for spring return actuators and pneumatic actuators NO Pressure off/power off to OPEN NC Power off/pressure off to close Type AKK AKK FL GK B20 B30 B32 B40 B42 BP0 BP2 BR0 BR2 TN For information on Open/Close actuators see the Control Units catalogue, K5-3.3 Surcharge 288

39 Prisliste DKK 2019 brutto ekskl. moms SHUT-OFF AND RESTRICTION Flow adjustment dampers VFR (ød) For the reliable balancing of volume flow rates VFR A2 / 160 / E01 Type VFR Flow adjustment damper Material No entry: galvanised sheet steel A2 Stainless steel [mm] 80, 100, 125, 140, 150, 160, 180, 200, 224, 250 Actuator No entry: manual operation For example E01 24 V AC/DC, 3-point, potentiometer E03 24 V AC/DC, modulating, 0-10 V DC, potentiometer M01 24 V AC/DC, 3-point, mechanical stops Type VFR VFR A2 E01 E02 E03 M01 M Base price Surcharge For detailed information on Min/Max actuators and modulating actuators see the Control Units catalogue, K

40 VOLUME FLOW RATE MEASUREMENT Volume flow rate measuring units VMR Prisliste 2019 DKK brutto ekskl. moms (ød) For the measurement of volume flow rates in ducts VMR P1 FL / 160 / G2 / B10 / E0 Type VMR Circular volume flow rate measuring unit Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey A2 Stainless steel Flange FL Flanges on both ends [mm] 100, 125, 160, 200, 250, 315, 400 Accessories D2 Lip seals on both ends G2 Matching flanges for both ends Attachments (differential pressure transducer) B10 Dynamic differential pressure transducer BB0 Static differential pressure transducer Signal voltage range For the actual value signal Only for attachment B10 E V E V Type VMR VMR- - VMR- -A2- VMR- - VMR P1 FL D2 G2 A2 FL G2 B10 BB Surcharge For information on dynamic and static differential pressure transducers see the Control Units catalogue, K5-4.2 Restricted availability of equipment combinations: -P1, -A2 not with dynamic differential pressure transducer (B10) / DE/en

41 Prisliste DKK 2019 brutto ekskl. moms VOLUME FLOW RATE MEASUREMENT Volume flow rate measuring units VMRK (ød) For the measurement of volume flow rates in ducts with contaminated air VMRK FL / 160 / GK / BB0 Type VMRK Volume flow rate measuring unit, plastic Flange FL Flanges on both ends [mm] 125, 160, 200, 250, 315, 400 Accessories GK Matching flanges for both ends Attachments (differential pressure transducer) BB0 Static differential pressure transducer Type VMRK VMRK FL GK BB Base price Surcharge For information on static differential pressure transducers see the Control Units catalogue, K

42 VOLUME FLOW RATE MEASUREMENT Volume flow rate measuring units VME Prisliste 2019 DKK brutto ekskl. moms (H) (B) For the measurement of volume flow rates in ducts VME P1 / / B10 / E0 Type VME Rectangular volume flow rate measuring unit Material No entry: galvanised sheet steel P1 Powder-coated (RAL 7001), silver grey [mm] B H Attachments (differential pressure transducer) B10 Dynamic differential pressure transducer BB0 Static differential pressure transducer Signal voltage range For the actual value signal Only for attachment B10 E V E V Type VME B H VME P1 B10 BB Surcharge Type VME B H VME P1 B10 BB Surcharge For information on dynamic and static differential pressure transducers see the Control Units catalogue, K5-4.2 Restricted availability of equipment combinations: P1 not with dynamic differential pressure transducer (B10) 292

43 Prisliste DKK 2019 brutto ekskl. moms HEAT TRANSFER Heat exchanger WT H B For the reheating of airflows in rectangular ducting WT / 160 Type WT Hot water heat exchanger for VAV terminal units TZ-Silenzio and TVZ 125, 160, 200, 250, 315, 400 Type WT for Types TZ-Silenzio and TVZ WT

44 HEAT TRANSFER Heat exchanger WT Prisliste 2019 DKK brutto ekskl. moms (H) (B) For the reheating of airflows in rectangular ducting WT / Type WT TVT Hot water heat exchanger for CAV controllers EN and for VAV terminal units TVJ and [mm] B H Type WT for Types TVJ, TVT, EN B H WT

45 Prisliste DKK 2019 brutto ekskl. moms HEAT TRANSFER Heat exchanger WT Type WT for Types TVJ, TVT, EN B H WT for EN B H WT Price 295

46 HEAT TRANSFER Heat exchanger WL Prisliste 2019 DKK brutto ekskl. moms (ød) For the reheating of airflows in circular ducting WL / 160 Type WL and VFC Hot water heat exchanger for VAV terminal units TVR and CAV controllers RN [mm] 100, 125, 160, 200, 250, 315, 400 Type WL WL

47 Prisliste DKK 2019 brutto ekskl. moms HEAT TRANSFER Heat exchanger EL (ød) For the electric reheating of airflows in circular ducting EL / 160 Type EL or VFC Electric air heater for VAV terminal units Type TVR and for CAV controllers Type RN [mm] 100, 125, 160, 200, 250, 315, 400 Type EL EL

48 TROX Danmark A/S Lyskær Herlev Tlf.: Salgskontor Danmark Lysholt Allé Vejle Tlf.:

TROX Prisliste Spjæld Riste Lyddæmpere K3-00

TROX Prisliste Spjæld Riste Lyddæmpere K3-00 TROX Prisliste 2019 Spjæld Riste Lyddæmpere K3-00 K1 - ARMATURER, RISTE Ceiling swirl diffusers AIRNAMIC...7 VDW...8 TDV-SilentAIR...9 RFD...10 FD...11 TDF-SilentAIR...12 VD...13 VDL...14 FDE...16 Design

More information

TROX Prisliste Armaturer Riste K1-00

TROX Prisliste Armaturer Riste K1-00 TROX Prisliste 2019 Armaturer Riste K1-00 K1 - ARMATURER, RISTE Ceiling swirl diffusers AIRNAMIC...7 VDW...8 TDV-SilentAIR...9 RFD...10 FD...11 TDF-SilentAIR...12 VD...13 VDL...14 Design ceiling swirl

More information

TROX Prisliste Filtrering K7-00

TROX Prisliste Filtrering K7-00 TROX Prisliste 2019 Filtrering K7-00 K1 - ARMATURER, RISTE Ceiling swirl diffusers AIRNAMIC...7 VDW...8 TDV-SilentAIR...9 RFD...10 FD...11 TDF-SilentAIR...12 VD...13 VDL...14 FDE...16 Design ceiling swirl

More information

TROX Prisliste Filtrering K7-00

TROX Prisliste Filtrering K7-00 TROX Prisliste 2017 Filtrering K7-00 TROX Danmark A/S Lyskær 10 2730 Herlev Tlf.: +45 49 14 66 33 www.trox.dk Salgskontor Danmark Lysholt Allé 10 7100 Vejle Tlf.: +45 86 25 19 11 www.trox.dk K1 - ARMATURER,

More information

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1 X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic

More information

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Homepage > Products > Control Systems > Variable volume flow control > VAV terminal units > Type TVLK Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Plastic circular VAV terminal units

More information

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K . X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for

More information

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers

More information

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers

More information

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Shut-off dampers. Type AKK. For contaminated air PD AKK 1 X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems

More information

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL Control units Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL The art of handling air Ventilation and air conditioning systems must fulfil complex and demanding requirements. With

More information

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN. Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN Type EN FOR THE PRECISE CONTROL OF NORMAL AND HIGH CONSTANT VOLUME FLOWS

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Type AK FOR LOW-LEAKAGE SHUT-OFF Circular shut-off dampers for shutting off volume flows in ventilation ducts

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume

More information

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

Parts and characteristics

Parts and characteristics Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Installation and commissioning manual GB/en VAV terminal units VARYCONTROL LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Read the instructions prior to performing any task! TROX GmbH Heinrich-Trox-Platz

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1 X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts

More information

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400 Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Hoepage > Products > Airflow Control - VAV and CAV > Variable air volue flow control - VARYCONTROL > Secondary silencer > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Hoepage > Products > Sound attenuators > Circular silencers > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Circular silencers Type CA for the reduction

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Home > PRODOTTI > Unità di regolazione > VARYCONTROL > Unità terminali VAV > Serie TVA Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control

More information

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, aluminium construction Circular silencers, in rigid aluminium construction, for the reduction of noise in the

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Homepage > Products > Sound attenuators > Circular silencers > Type CS Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Circular silencers, in rigid aluminium construction,

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Homepage > Products > Air Diffusers > Industrial diffusers > Diffusers for high momentum > Type ISH Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Impulse diffusers with horizontal air discharge

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

Multileaf damper with actuator

Multileaf damper with actuator JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en) 4/S6 v 2.5 (en) VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T www.klimaoprema.hr 253 TABLE OF CONTENTS Variable air volume control damper - round... 255 Variable air volume control damper - rectangular...

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation

More information

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers Type volume flow controllers series volume flow controllers General information Correct use Safety notes Area of application Operating modes Product description Installation Commissioning and wiring 5

More information

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1 X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser

More information

Floor Swirls Models BZD and SZD

Floor Swirls Models BZD and SZD July 09 Floor Swirls Floor Swirls Models BZD and SZD Features Model BZD Circular Floor Swirl Model SZD Circular Step Diffuser Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk

More information

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL. Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows

More information

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with

More information

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL

More information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type VSD35. Nominal length up to 1500 mm: one spigot Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements

More information

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Hoepage > Products > Sound attenuators > Circular silencers > Type CF Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Circular silencers, in flexible aluiniu construction,

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic T.3//EN/ Floor diffusers Type FB In aluminium and plastic The art of handling air Contents Description Description Installation examples 3 Construction Dimensions Plenum box Load capacity Installation

More information

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S JET DIFFUSERS DCJ SERIES DCJ SERIES DCJ SERIES JET DIFFUSERS Application Colman s DCJ jet diffuser has been designed to supply cooled

More information

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser Halton DKR Multi-nozzle Ceiling Diffuser Horizontal air supply, vertical air patterns are also possible Supply air pattern can freely be directed in up to four directions or alternatively radially as swirl

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf

More information

Mechanical mixing box MBM

Mechanical mixing box MBM Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

VAV Terminal Units SDS

VAV Terminal Units SDS VAV Terminal Units SDS VAV Terminal Units SDS STEKON SDS; controls the volume of conditioned air into an occupied space in response to a thermostat or Building Management System control signal with minimal

More information

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser Halton DKS Multi-nozzle Ceiling Diffuser Horizontal air supply, vertical air patterns also possible Supply air pattern can freely be directed in up to four directions or alternatively radially as swirl

More information

ceiling swirl diffuser DQJ

ceiling swirl diffuser DQJ ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

... TROX UK LABCONTROL Facility

... TROX UK LABCONTROL Facility .. 111 TROX UK LABCONTROL Facility .. TROX Test Laboratory LABCONTROL Length = 9.0m Width = 4.0m Height = 4.0m Laboratory Facilities: The Lab is equipped with two Köttermann 1200mm wide general-purpose

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

SDV Vane Swirl Diffusers

SDV Vane Swirl Diffusers SDV Vane Swirl Diffusers SDVSA Square plate vane swirl diffuser (angled slot) SDVCA Circular plate vane swirl diffuser (angled slot) SDVSB Square plate vane swirl diffuser (normal slot) SDVCB Circular

More information

Air Displacement Vent Units

Air Displacement Vent Units T 1.3/5/EN/1 Air Displacement Vent Units Type QSH ISH TRO GmbH Telephone +49/28 /2 02-0 Telefax +49/28 /2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents

More information

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic 1/8/EN/6 Floor Diffusers Type FB in aluminium and plastic Contents Description Description Construction Dimensions 3 Dimensions GA GAM 4 Installation Examples 5 Installation Fixing Details 6 Materials

More information

Particle Filter Box Model FKF

Particle Filter Box Model FKF Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Ceiling diffuser 4DE

Ceiling diffuser 4DE Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

June 2009 Quick Selection Guide

June 2009 Quick Selection Guide Issue Date June 2009 Quick Selection Guide Quick Selection This selection guide has been designed to allow quick and simple selection for a broad range of TROX Grille and Diffuser product. Full product

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel

More information

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied

More information

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser Halton TCM Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Suitable for cooling applications with supply/room air temperature difference as low as -12 C Installation flush to

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

VAV controller. TROX Auranor Norge AS. Telephone Fax

VAV controller. TROX Auranor Norge AS. Telephone Fax GB0814 11.18 LØV-R VAV controller New regulator handles larger working area Low noise level Pressure independent Short overall length High measurement accuracy Can be installed directly in bend Flexible

More information

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación > Rejas para instalación en intemperie > Rejas para instalación a intemperie > Type WG-JZ Type WG-JZ COMBINATION WITH A MULTILEAF

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information