1 Catalog Duct diffuser RRA
2 Orford Arts Centre, Orford, Canada
3 content RRA model Description, Areas of application and Benefits RRA 1 Configuration RRA 2 Range of application RRA 3 Selecting the quantity of slots RRA 4 Control of the direction of the air jet RRA 5 Diagram Discharge velocity RRA 6 Horizontal discharge course deviation RRA 7 Acoustic power level RRA 8 Pressure loss RRA 9 Example RRA 10 Dimensions and weight RRA 11 Suspension system RRA 12 Specifications RRA 15 Codification RRA 16 Codification of Anchoring System RRA RRA C
4 Munich Airport, Germany
5 Description, Areas of application and Product Benefits RRA The RRA is an exposed duct section linear diffuser designed for the commercial and industrial sectors and for comfort zones. It is perfectly suited to those applications in which functionality must be optimal but must also harmonize with an architectural design. Due to the perfect integration of eccentric cylinders characteristic of NAD Klima technology, the circular RRA diffuser provides a multitude of discharge air directions. All air conditioning and heating situations find an RRA application where esthetics, technical expertise and great comfort combine. Areas of application - Commercial sector - Ventilation of large halls - Office spaces - Entrance halls, atriums - Commercial and industrial spaces - Residential spaces - Buildings with an exposed wooden structure - Agoras Product benefits - Setting for diffused, divergent and vertical air blast, or any other intermediate position - Easy adaptability of airflow to a variety of purposes in the premises - Combination of all forms of air blast possible in one single diffuser - Rapid reduction of velocity and temperature variations due to high induction - Installation at any point of a duct system in different configurations: horizontal, vertical, etc. - Connects with any ductwork or accessory respecting the SMACNA standards - Thermostatic paint finish in colours from the RAL colour chart - Easy to clean finish (with a multifilament brush) - Eliminates need of secondary hookups and traditional diffusers - Eccentric cylinders permitting adjustment of air blast in a range of Possibility of reducing total airflow rate up to 25% in VAV - Possibility of eliminating peripheral heating under certain conditions from the RAL colour chart Subject to technical changes. Version 07 / 06 / RRA 1
6 Configuration Operation of the RRA The RRA duct section linear diffuser can be installed at any point within a system and in any position: vertical, horizontal, etc. The air stream flows through the diffuser in the direction of the length, and the discharge air is intercepted perpendicularly by the lateral blades of the eccentric cylinders. Many duct section linear diffusers can be mounted in a continuous fashion, but the aeraulic balancing must then be completed by accessories and ductwork. Ducts Composition The slots hold eccentric ABS cylinders (black, cream or white) 100 mm in length. The cylinders are equipped with alphanumerical guides permitting the adjustment of the pattern of air diffusion in a 1800 range. The RRA diffuser is fabricated in diameters ranging from 200 mm up to 1419 mm. In order to maintain the circular shape of the ductwork, reinforcement pieces are installed inside all ducts longer than 433 mm. At each extremity, a circular EPDM seal is inserted into a groove to ensure proper sealing when many sections are to be mounted. The RRA diffuser is generally installed in a visible ventilation segment. It is recommended, for reasons of aesthetics among others, to use the same setup and finish for all accessories appearing in this same visible segment. Passive ducts without slots are available in the same sizes as the active RRA ducts. Assembling The RRA diffuser sections are assembled by use of connecting sleeves adapted to the duct's diameter. Accessories All standard RRA accessories (elbows, connecting sleeves, reducers, branches, etc) are available in precise duct sizes. Standard Sleeve (120 mm) (RRA are joined) X = 0 X 120 Special Sleeve ( Spacing between RRA ) X = from 1 mm to 1380 mm X Active duct Bivelled end cap Passive duct Accessories Sleeve Cap Wheel cone Elbows Centric Reducer Eccentric Reducer S Branch W Branch T Branch D Branch Curve 90 Straight RRA Subject to technical changes. Version 16 / 08 / 2012
7 Range of application Maximum Installation Space Air Flow by meter of slot of. RRA V o Height of installation of RRA H Space recommended between RRA X MAXIMUM m 3 /h/m (cfm/li. ft) m (ft) m (ft) (10-22) 3 (10) 5 (16) (22-27) (27-31) (10-15) (15-23) 7 (22) 8 (26) x x x x Cooling only: maintain the maximum X distance according to the height but maintain the air flow per slot meter of m 3 /hm. Balancing Airflow and Positioning Reducers In order to optimize uniform airflow in the RRA diffuser sections, we recommend installation of a reducer after the 5th active section (See 1 following). In order to preserve diameter uniformity of a diffusing section, a balancing damper can be used instead of the reducer after the 5th active section. We also recommend installing a balancing damper, either from the 4th section such as indicated (See 2). 1 x x x x Select the diameter of the conduit by considering a speed of air inlet 5 m/s or 1000 fpm. 2 1 perfored register 2 slot exterior wall of duct RRA eccentric drum section with register Subject to technical changes. Version 16 / 08 / RRA 3
8 Selecting the quantity of slots Selecting the quantity of slots m 3 /h/m (cfm/li.ft) n = number of slots Air flow V. by active slot lengths of 1 m 1500 (269) 1300 (233) (179) 900 (161) (143) 700 (125) 600 (108) (90) (72) (54) (36) (18) (9) 75 active slots lengths of 1 m active slots lengths 75 of 1 ft 2. Air Flow by meter of slot of RRA V 0 m 3 /h/m (cfm/li.ft) Cooling Mode Only, for all Ceiling Heights (10-22) Heating and cooling or cooling only for ceiling heights of 3.0 m. Heating and cooling or heating only for heights of 4.5 m m* (22-27) Heating and cooling or heating only for ceiling heights of 4.5 m m* (27-31) * validate the sound level -If the heating mode to the heights above 3 m can be selected to an initial rate, reduce the length Ls of the slot in accordance with the air flow per meter of recommended slot DN Important : In order to facilitate RRA selection, it is essential to calculate the total airflow rate for active lengths of 1 m. Specifications: Height of base of ductwork: H = 4.00 m. Airflow rate by diffuser: Vo = 520 m 3 /h Cooling: T = - 10 C Heating: T = +10 C Length of RRA: L R = 1500 mm Requirements: 1- Airflow rate per metre of slot section 2- Number of slots n Solution: 1 1-The length of RRA slot is determined as follows: L S = L R mm = 1300 mm The airflow rate is calculated by number of. slot section metres. V o [m 3 /h RRA] X F = V o [m 3 /h/m] 680 [m 3 /h] X 0.77 = 400 [m 3 /h/m] 2 From diagram "Selecting the quantity of slots", for a height of 4 m and for a heating application, we note the number of slots : n = 3 Airflow conversion by 1 meter slot length :.. V o [m 3 /h/m RRA] X F = V o [m 3 /h/m].. V o [cfm/rra] X F = V o [cfm/li.ft.] Lenght of RRA L R Slot lenght L S (mm) [Li.ft.] (800) (900) (1000) (1100) (1200) (1300) (1400) (1500) (1600) (1700) (1800) [2.62] [2.95] [3.28] [3.60] [3.94] [4.27] [4.60] [4.92] [5.25] [5.58] [5.90] Multiplication factor F [0.382] [0.339] [0.305] [0.278] [0.254] [0.235] [0.217] [0.203] [0.190] [0.179] [0.170] L S (ex : 1300) L R (ex : 1500) Standard RRA Subject to technical changes. Version 16 / 08 / 2012
9 Control of the direction of the air jet Controling direction of air blast Due to the various depression zones created by the eccentric cylinder, airflow can be adjusted on the entire 1800 range. (This is illustrated in the following diagram) Application examples slots at 0 Air direction 6 m (20 ft) 6 5 / B C Diffuse 2 1 / 6 5 Diffuse 2 1 / D E Diffuse 1.8 m (6 ft) 3 m (10 ft) B C / E F Diffuse A B / E F Diffuse A B / D E Diffuse 1.8 m (6 ft) 4 m (13 ft) C D Diverging A B - E F Diverging C D Diverging 1.8 m (6 ft) figure A figure B figure C As a result, airflow combinations are virtually infinite. Each project benefits from personalized adjustments made by the manufacturer in the plant. Standard setting for cylinders is as follows: diffused mode on alternating positions 2 1 and 6 5. This setting provides high induction that can be used during heating and cooling modes when high air changeover figures are needed. Figures A and B show the most frequently used settings. On the other hand, the divergent mode allows directing air blasts with more precision. This mode permits the production of a longer thrust of airflow. Specific zones, usually difficult to service, can in this way benefit from personalized settings. Figures C and D illustrate the position of the eccentric cylinder and the corresponding air blast direction discharging from the cylinder. It must be noted that to maximize air projection, multiple air blasts can be oriented in the same direction in order to optimize servicing a zone, even in heating mode. Application examples slots at +90 A B / C D Diffuse figure D All Heights C D / E F Diffuse 1.8 m (6 pi) Diverging 1.8 m (6 pi) 5.4 m (18 pi) 180 (12h) -90 (9 h) Indexing range Volume flow min. max. 0 (6 h) +90 (3 h) Note : Coding faces the air jet Direction of airflow Subject to technical changes. Version 16 / 08 / RRA 5
10 Discharge velocity diagram Airstream pattern (drum position) V max = k1 x V max diagram Diffuse (1 x 2 1 / 1x 6 5) standard 2 3 Diverging (left half right half 6 5) Number of slots n 1 Airflow distance after the blast [m] 2,2 Volume flow V 0 [m3/hm slot] (30) 6 (40) (50) (60) = 0,4 m/s (80 pi/m) Air flow distance x [m] y = 2.2 m y 1.8 m 4 m airflow velocity v max (100) (120) X X X X 8 C 7 Vertical (All C D) y y Vertical penetration depth y max [m] Temperature difference T C C C C RRA Subject to technical changes. Version 16 / 08 / 2012
11 Horizontal discharge course deviation Air Flow V /hm slot Temperature T [ C] number of slots n Vertical deviation y [m] X x[m] y The values of y are valid for the setting "horizontal air blast, diffused". For the setting "horizontal air blast, divergent", the value is to be multiplied by the factor 0.9. Additionnal airflow deviation y as a result of the airflow discharge angle Subject to technical changes. Version 06 / 08 / RRA 7
12 Acoustic power levels diagram 37 figure E 2 Specifications : - Total Airflow : 2080 m³/h - Number of section of RRA : 4 - Number of slot by RRA : 3 - RRA length : L R =1500 mm - Slot length : L S =1300 mm Requirement : - What is the sound power generated L WA? Acoustic power level L WA [db(a)] 1 V 0 [m 3 /h/m slot] drum position CD 1 A or F 6 A B or E F Solution : For determinate the sound power generated by the diffuser RRA, we must first calculate the air flow by meter of slot. From the total airflow, the quantity of section and number of slot by section, we find : (2080 m 3 /h 4 RRA) 3 slots = 173 m 3 /h by slot For a slot length of 1300 mm, calculate the total air flow by meter of slot : 173 m 3 /h X 0.77 = 133m 3 /h/m slot (see page 4) 1 - From the diagram of acoustic power level, we read : L WA diagram = 37 db(a) 2 - The table below and a number of slot n = 3 : L WA = 6.8 db(a) 3 Finaly, the sound power generated is : L WA = L WA diagram + L WA = 43.8 db(a) - 10 db(a) = 33.8 db(a) Number of slot n L R L WA = L WA Diagram + L WA S L R S L R S L R S L WA L WA L WA L WA 3 L R = duct length L S = slot length Standard RRA Subject to technical changes. Version 16 / 08 / 2012
13 Pressure Loss Duct diameter " D " mm (in.) 200 (8) r ΔP duct ΔP * Pressure loss by diameter in elbows = 1.5 L ΔP * Reducer D L ΔP Pressure drop by diameter of regular duct 5 m/s (1000 ppm) Pa / m (" water / 100ft) 1.63 (0.20) m 3.13 D 90 ft 10 m 2.48 D 60 ft 7 m 1.93 D 45 ft 5 m D 0.92** 14 ft d 3** Air flow for slot length of 1 m 3 m /hm (cfm/ft) 50 (9) ΔP drum ΔP Pressure loss for slot length of 1 m (1A/F6) Pa ( " water ) 21 (0.08) 251 (10) 1.31 (0.16) (10) 22 (0.09) 302 (12) 1.06 (0.13) (11) 22 (0.09) 353 (14) 0.82 (0.10) (12) 23 (0.09) 403 (16) 0.73 (0.09) (13) 24 (0.09) 454 (18) 0.65 (0.08) (13) 24 (0.10) 505 (20) 0.57 (0.07) (14) 25 (0.10) 556 (22) 0.49 (0.06) (15) 26 (0.10) 607 (24) 0.41 (0.05) (16) 27 (0.11) 657 (26) 0.41 (0.05) (17) 27 (0.11) 708 (28) 0.37 (0.045) (18) 28 (0.11) 759 (30) 0.37 (0.045) (19) 29 (0.12) 810 (32) 0.33 (0.040) (20) 30 (0.12) 861 (34) 0.29 (0.035) (21) 31 (0.12) 911 (36) 0.29 (0.035) (22) 33 (0.13) 962 (38) 0.24 (0.030) (22) 34 (0.14) 1013 (40) 0.24 (0.030) (23) 35 (0.14) 1064 (42) 0.24 (0.030) (24) 36 (0.14) 1115 (44) 0.20 (0.025) (25) 38 (0.15) 1165 (46) 0.20 (0.025) (26) 39 (0.16) 1216 (48) 0.20 (0.025) (27) 40 (0.16) 1267 (50) 0.16 (0.020) (28) 42 (0.17) 1318 (52) 0.16 (0.020) (29) 43 (0.17) 1369 (54) 0.16 (0.020) (30) 44 (0.18) 1419 (56) 0.16 (0.020) (31) 45 (0.18) *ΔPL Equivalence in lenght of pressure loss ** Based on P = 0.82 Pa/m (0.1 " of water / 100ft) Correction factor for different air velocity in duct : ΔP = F x ΔP (v=1000ppm) Air velocity in duct m/s (ppm) 3 (600) 4 (800) 5 (1000) 6 (1200) 7 (1400) ΔP Pressure drop by diameter in straight duct F ΔP Pressure drop in elbows F ΔP Pressure drop in reducer F Recommended Factor of correction for different adjustments of drums : ΔP = F x ΔP (standard adjustment) Roll adjustment 1 A / F 6 A B / E F C D 2 1 / / 5 4 C D / C D / 2 1 ΔP Pressure loss for slot lenght of 1 m. F Subject to technical changes. Version 16 / 08 / RRA 9
14 Calculation Example 20 m Zone 1 Zone m Total air flow : 1232 m 3 /h (725 cfm) Direction of the air flow 5 m 4 m Total air flow : 4160 m 3 /h (2908 cfm) Data: Air diffusion in two zones Velocity of airflow in duct : Temperature variation: Height of duct: 5 m/s (1000 ppm) T = +10 C 4 m Zone 1: comprising 2 runs of duct Run n 1: - 4 x (active RRA, L = 1500 mm, D = 657 mm ) - airflow rate per RRA: 520 m 3 /h Run n 2: - 1 reducer (657 mm to 505 mm) - 4 x (active RRA, L = 1500 mm, D = 505 mm ) - 1 x (passive RRA, L = 1500 mm, D = 505 mm) - 2 x (90 elbow, D = 505 mm ) - airflow rate per RRA: 520 m 3 /h Zone 2 : comprising 1 run of duct - 1 reducer (505 mm to 302 mm) - 4 x (active RRA, L = 1500 mm, D = 302 mm ) - 1 x (end cap, D = 302 mm) - airflow rate per RRA: 308 m 3 /h Questions: 1. What is the total airflow rate per metre of slot for every zone and the number of corresponding slots? 2. What is the level of sound power L WA? 3. What are the pressure drop of the installation? Solutions : 1. The total airflow rate per metre of slot depends on the rate diffused by RRA Zone 1: for an airflow rate per RRA of 520 m 3 /h 1 and a length of 1500 mm, the airflow rate by metre of slot is calculated thus: 520 m 3 /h x 0.77 = 400 m 3 /h/m. From diagram "Selecting the quantity of slots" on page 4, for a heating mode and a duct height of 4 m, we note the number of slots: n = 3. 2 Zone 2: in the same manner, the airflow rate per metre of slot section is calculated: 308 m 3 /h x 0.77 = 237 m 3 /h/m, we note the number of slots: n = From diagram "Sound Power", an adjustment of eccentric cylinders at 2 1/6 5 (diffused) and 3 slots per RRA: 400 m 3 /h/m 3 = 133m 3 /h/m L WA = L WA DIAGRAM + L WA = = 43.8dB(A) - 10dB(A) = 33.8 db(a) 3 3.The pressure drops of the installation are due to air restriction through the cylinders and to friction of the air along the interior surfaces of the ductwork, linear pieces, elbows and reducers. 3.1Pressure drops at cylinders: from diagram "Pressure Drops"and an airflow rate per metre of slots of 133 m 3 /h/m, we note: P 3.1 = 35 Pa Zone 1, section 1 - The total length of 4 x active RRA of a diameter D = 657 mm is: L = 4 x 1500 mm = 6 m, where: P = 6 m x 0.41 Pa/m = 2.5 Pa Zone 1, section 2 - The total length of 4 x active RRA and 1 x passive RRA of a diameter D = 505 mm is: L = 5 x 1500 mm = 7.5 m, where: P = 7.5 m x 0.57 Pa/m = 4.3 Pa Zone 2 - The total length of 4 x RRA active of diameter D = 302 mm is : L = 4 x 1500 mm = 6 m, where: P = 6 m x 1.06 Pa/m = 6.4 Pa -The total pressure loss of the ducts is: P 3.2 = = 13 Pa 3.3 The pressure loss in reducers. The pressure loss equivalent in length for 2 reducers (α = 14 ) is: P L = 2 x 0.92 m = 1.84 m, where: P 3.3 = 1.82 m x 0.82 Pa/m = 1.5 Pa 3.4 The pressure loss in bends. The pressure loss equivalent in length for 2 90 elbow of a diameter D=505 mm is : P L = 2 x 5.13 m = 10.3 m, where: P 3.4 = 10.3 m x 0.57 Pa/m = 6 Pa Finally, the total pressure loss of the installation is: P 3 = P P P P 3.4 thus: P 3 = 55.5 Pa Note: For an installation height of 4 m, one single circular RRA duct will be sufficient to cover a width of 10 m. -The positioning of the slots at 00 (6 on the clock ) with a cylinder adjustment in A B / E F (diffused) 3.2 Pressure drops per diameter of linear ducts are: without sleeve RRA Subject to technical changes. Version 16 / 08 / 2012
15 Dimensions and Weights Duct lenght - L R Slot lenght - L S Weight per slot (Kg) Weight of the passive RRA (Kg) Diameter of RRA (mm) Sheet thickness : 0.85 mm Sheet thickness : 1.00 mm Standard Subject to technical changes. Version 06 / 08 / RRA 11
16 Suspension System The RRA diffuser is suspended by thread bars supplied by the ventilation contractor (standard suspension method). On demand, thread bar covers in colours matching those of the ductwork are available for a more finished look. Other hanging methods are also available: aluminum track suspension (a method making hanging very easy) and metal cable suspension. These alternative hanging methods are available at NAD Klima. Thread Bar Suspension Rod covers available (optional) Rod covers available (optional) Track Suspension Rails junction Metal Cable Suspension RRA Subject to technical changes. Version 18 / 04 / 2012
17 Library room of the Cegep de Granby
18 Sport Centre Thibault/GM, Sherbrooke, Québec
19 Specifications of the RRA Model 1. Description and Physical Characteristics 1.1 RRA duct diffusers are made of satin-finish steel of mm (22-gauge) for diameters under 508 mm and 1mm (20-gauge) for diameters equal to or over 508 mm. These are designed with slots that house integrated eccentric cylinders in ABS (black, cream or white). Cylinders come equipped with an alphanumerical guide disk designed to allow adjusting airflow diffusion patterns on a range of This same diffuser may be a passive one, that is, without slots and eccentric cylinders. 1.3 Each duct is painted inside with a baked polyester TGIC-base enamel which ensures a smooth easy-to-clean surface. Client or architect may choose among the standard colours of the RAL chart or select other colours on demand. (Painting inside is also available on demand) 1.4 The RRA circular duct diffuser is supplied with diameters ranging from 200 mm to 1419 mm. At each extremity of a RRA diffuser, an EPDM 65 DURO seal is inserted into a groove to ensure proper sealing before the ductwork leaves the plant. The sections of the RRA diffuser are joined together with connecting sleeves. 1.5 In order to optimize uniform airflow in the sections of RRA diffusers, balancing dampers can be installed right on the duct, otherwise reducers must be added between many sections. Dampers are mounted from the fourth section. 1.6 The ductwork has a surface with the smoothest finish possible and connecting joints as fine as possible (less than 3 mm), in order to present an architectural appearance of the highest standard. The diffusers are cleaned simply by using a duster set up on a telescopic aluminum pole, thereby eliminating the use of a maintenance platform or a high stepladder. 1.7 In order to ensure the circular form of the duct and to optimize the smooth exterior finish, metallic support pieces are installed inside the ductwork exceeding 433 mm (17 inches) in diameter. 2. Installation and Suspension Method 2.1 The RRA diffuser is suspended by thread bars supplied by the ventilation contractor. 3. Performance Manufacturer must also demonstrate for approval: 3.1 Performance curves indicating air velocity for the distance travelled, pressure drops and level of sound power generated by the RRA diffuser. 3.2 Simulation of airflow distance while factoring in physical layout of installation and state of comfort in occupied zones, in all three modes, that is, cooling, isothermal and heating. 4. Setting 4.1 Adjusting of eccentric cylinders is individually adapted to each application. This setting allows for comfortable ventilation in all the occupied zone with air velocities acceptable at head height (1.8 m). This setting must be made by manufacturer in the plant. 4.2 Each RRA diffuser is identified by a sticker. This marker carries the RRA section number, the airflow direction, the number of slots, and the setting of the eccentric cylinders. 4.3 In case of changes made to the layout of the premises, resetting the eccentric cylinders remains possible, even after installation of the RRA diffusers, in order to meet the new requirements in airflow diffusion. 4.4 Resetting the eccentric cylinders after installation of circular diffusers is must be implemented using the method proposed by the manufacturer. 5. Balancing 5.1 Balancing of the RRA diffusers must be accomplished by a technician qualified in ventilation system balancing with a certificate of professional competence. 5.2 The technician must be familiar with adjusting eccentric cylinders and with divergent and diffused modes, the data about which are available in our technical documents. 6. Required Quality: NAD Klima, RRA model. 2.2 As an option, thread bar covers in colours matching those of the ducts are available for a more finished look. 2.3 As another option, aluminum track suspension can also be supplied by the manufacturer. The aluminum track is suspended and the RRA diffuser is slid into the track, thus allowing a solution for various types of ceiling structures. The track can be painted to match the colour of the ductwork. 2.4 Another possibility is a metal cable suspension of "aviation cable " type, (7x7 or 7x19) in galvanized or stainless steel (304 or 316), of medium or high traction resistance that can be provided by the manufacturer 2.5 Standard accessories are supplied by the manufacturer (elbows, reducers, branches, etc). Subject to technical changes. Version 07 / 06 / RRA 15
20 Codification for RRA duct diffusers RRA 1000 (800), 1500 (1300), 1800 (1600), 2000 (1800) 200, 251, 303, 353, 403, 454, 505, 553, 607, 657, 708, 759, 810, 861, 913, 962, 1013, 1064, 1115, 1165, 1216, 1267, 1318, 1369, = Passive 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, Product Length L R (L S ) Ø Duct diameter Number of slots 006 = Slots at 0 (6h) 003 = Slots at +90 (3h) 009 = Slots at -90 (9h) 012 = Slots at 180 (12h) 039 = Slots at +90 (3h) and at -90 (9h) 612 = Slots at 0 (6h) and at 180 (12h) AAA = Other (specify in annotation) XXX = Passive duct Slots position ou DE / 21 DVW = Diverging wall BC - 65 DVV = Diverging vertical CD XXX = Passive 9003 = White 9010 = Cream = RAL colours * (write the number of colour) W = White drum (RAL 9003) C = Cream drum (RAL 9010) B = Black drum X = Without drum X = Without damper D = With damper R = With register (perforated plate) S = Standard V = Motorised Airflow pattern/ Rollers adjustment Colour Drums Setting RRA DFS W - X - S Annotation : Example Codification for reducers RRA RED = Reducer Product 203, 254, 305, 356, 406, 457, 508, 559, 610, 660, 711, 762, 813, 864, 914, 965, 1016, 1067, 1118, 1168, 1219, 1270, 1321, 1372, 1422 ØD ød Ø Input size 203, 254, 305, 356, 406, 457, 508, 559, 610, 660, 711, 762, 813, 864, 914, 965, 1016, 1067, 1118, 1168, 1219, 1270, 1321, 1372 T = Flat on Top (standard) E = Equal B = Flat on Bottom T E B S = Standard α = 14 A = Other (specify in annotation) 14 Ø Output size Configuration Length 9003 = White 9010 = Cream = RAL colours * (write the number of colour) Colour RRA - RED T - S Annotation : Example Notes: Blue: Standard size Write the four (4) digit number of the RAL colour chart Our powder paint colours are available in the RAL chart colours only. Metallic colours available upon request RRA Subject to technical changes. Version 16 / 068 / 2012
21 Duct diffuser Codification for elbows RRA ELB = elbow 15, 30, 45, 60, 90, QA QA 203, 254, 305, 356, 406, 457, 508, 559, 610, 660, 711, 762, 813, 864, 914, 965, 1016, 1067, 1118, 1168, 1219, 1270, 1321, 1372, 1422 S = Standard ( based on : r = 1.5D) A = Other ( specify in annotation) 9003 = White 9010 = Cream = RAL colours * (write the number of colour) Product Angle Ø Diameter Radius Colour RRA - ELB S Annotation : Example Codification for the branches RRA BRA = Branch Product 203, 254, 305, 356, 406, 457, 508, 559, 610, 660, 711, 762, 813, 864, 914, 965, 1016, 1067, 1118, 1168, 1219, 1270, 1321, 1372, 1422 ø d ø d ø d ø d Input size - ØD 203, 254, 305, 356, 406, 457, 508, 559, 610, 660, 711, 762, 813, 864, 914, 965, 1016, 1067, 1118, 1168, 1219, 1270, 1321, 1372, 1422 «D» Ø D «T» Ø D Output size - Ød T = «T» Branch D = «D» Branch W = «W» Branch S = Lateral branch ø d ø d ø d Configuration 9003 = White 9010 = Cream = RAL colours * (write the number of colour) «W» Ø D «S» Ø D Colour RRA - BRA T Annotation : Example X Codification for cap, sleeve and wheel cone RRA SLE = Sleeves CAP = End Cap WCO = Wheel Cone BEC = Bivelled End Cap Ø D 120 SLE CAP WCO BEC Product 203, 254, 305, 356, 406, 457, 508, 559, 610, 660, 711, 762, 813, 864, 914, 965, 1016, 1067, 1118, 1168, 1219, 1270, 1321, 1372, 1422 XXXX = Not applicable 0000 = Standard sleeve (distance between RRA is 0 mm) = Special - write the «x» value (distance between RRA)- from 0001 mm to 1380 mm maximum 9003 = White 9010 = Cream = RAL colours * (write the number of colour) Ø Size Length of the sleeve Colour RRA - CAP XXXX Annotation : Example Notes: Write the four (4) digit number of the RAL colour chart Our powder paint colours are available in the RAL chart colours only. Metallic colours available upon request Subject to technical changes. Version 07 / 06 / RRA 17
22 Duct diffuser Anchoring System Codification of additional accessories for anchoring by track Product code RKG Description Set of nylon guides Codification of accessories for anchoring by cable Product code Description of anchors to the ceiling CPA Gated hook with cable adjustment Bright nickel-plated Ø 13 mm X X mm (Ø 1/2" X 2 3/4" X 9/16") Ø 13 mm RKJ RKC RKG Set of plates for connectors Connector : 200 X 28 X 12 mm (7 13/16" X 1/2" X 1 1/16") Plate : 60 mm X 16 mm (2 3/8" X 5/8" ) Set of coupling with bolt and washer Stainless steel 5/16 3/8 Example CPP CPS Flat gripper with cable locking pin and cable adjustment 2 screws (#4 wood) incl. Anodized aluminium only. Ø 40 X ø 15 X 70 mm (Ø 1 5/8" X ø 9/16" X 2 3/4") Beam gripper with cable adjustment and locking pin screw (#4 wood) included Bright nickel-plated 13 X 55 mm (1/2" X 2 3/16") Product code RAI Description Rail Aluminium may be painted (1 1/4" X 1 3/4" X 10 li. ft) CCA Description of anchors to the duct (RRA) Cross-cable gripper with cable adjustment Bright nickel-plated Ø19 X 50 mm (Ø 3/4" X 2") RCT RAI Rod cover may be painted 16 mm X3.05 m (5/8" X 10 ft ) 9003 = White 9010 = Cream = RAL colour * (write the number of colour) XXXX = Unpainted Colour Example CCP CCS Sloped ceiling coupler Bright nickel-plated not ajustable Ø19 X 25 mm (Ø 3/4" X 1") Straigh gripper Bright nickel-plated not ajustable Ø19 X 25 mm (Ø 3/4" X 1") Notes : Write the four (4) digit number of the RAL colour chart Our powder paint colours are available in the RAL chart colours only. Cable : Ø 2.5 mm (3/32 ) 2, 3, 4, 5, 6, 7, 8, 9 meters A = Bright nickel-plated (standard) S = Stainless Steel (optional) Lenght of the cable Fittings Supplied with the Installation on track - Track - Set of nylon guides - Rail connectors - Set of plates for connectors CCS A Example RRA Subject to technical changes. Version 16 / 08 / 2012
23 TVA building, Montréal, Québec
24 NAD Klima 144, Léger street, Sherbrooke (Québec), Canada J1L 1L9 T : F : info@nadklima.com
NAD Klima Ontario 2840, Argentia Road, Unit 6, Mississauga (Ont) L5N 8G4 (416) Ø Diameter. r Radius. Coudes et raccords
Active diffuser Passive diffuser Submittal NAD Klima Ontario 2840, Argentia Road, Unit 6, Mississauga (Ont) L5N 8G4 (416) 860-1067 ontario@nadklima.com NAD Klima 144 rue Léger, Sherbrooke (Qué) J1L 1L9
More informationCatalog Swirl diffuser DAL 358
Catalog 1.1.1 Swirl diffuser DAL 358 Concordia University, Montréal, Canada DAL 358 model DAL 358 1 DAL 358 2 Method of operation............................................ DAL 358 3 Flow and direction
More informationCatalog Linear Diffuser SAL 50
Catalog 3 Linear Diffuser SAL 50 content SAL 50 Model Description, areas of application and benefits Configuration and operation mode 2 Air flow direction 3 Selection of the number of slots 4 Diagrams
More informationCatalog Swirl diffuser DAL 359
Catalog 1.1.1 DAL 359 Restaurant, Lingen, Germany DAL 359 Model Description, area of application and product benefits............ DAL 359 1 Configuration...................................................
More informationEz = 1.1. Swirl diffuser. Catalog DAL 358
Ez = 1.1 Catalog 1.1.1 Swirl diffuser DAL 358 Concordia University, Montréal, Canada swirl diffuser DAL358 " The diffuser surpassing all standards " The revolutionary DAL 358 stands alone as the reference
More informationMaintenance and installation guide
Swirl diffuser DAL 358 M A D E I N CANADA Maintenance and installation guide KEEP THIS GUIDE nadklima.com Québec NAD Klima (head office) 144 Léger, Sherbrooke (Qué) J1L 1L9 (819) 780-0111 1 866 531-1739
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More informationSlot diffusers, Round duct diffusers. IMP Klima
, Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING
More informationSLOT DIFFUSERS, ROUND DUCT DIFFUSERS
SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Slot diffusers LD-3, LD-4, LD-5 LD-3 LD-4 LD-5 SLOT DIFFUSERS Application: Slot diffusers are designed for air supply in rooms with floor to ceiling heights of 2.5
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser
More informationRound duct diffuser DBB-RR
Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationLinear diffuser SAL 50 Submittal
Linear diffuser SL 0 Submittal The SL0 is a diffuser with 0mm profiles wide. It is composed of extruded aluminum surfaces with eccentric rollers which slide inside and are mounted on the plenum, as well
More informationCornerAir. CornerAir. Active chilled beam
Active chilled beam Description The active chilled beam is a one-way induction type air-conditioning unit that is designed for exposed installation, mounted directly under the ceiling against the corner.
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationWALL VENTILATION GRILLES CBP
WALL VENTILATION GRILLES CBP 01.10-01 CBP WALL VENTILATION GRILLES Description Designed for ventilation and air-conditioning installations, where control of air flow and direction of the air is required.
More informationFALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable
More informationHIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY
HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY OVERVIEW CHARACTERISTICS APPLICATIONS KQ OVERVIEW : KQ high induction diffusers with variable geometry are a new type of air diffusion equipment. Their unique
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air
More informationType VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL
Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the
More informationType DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades
More informationRound duct grille Model KG-RR
Round duct grille Model KG-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationSlot diffusers for ceiling installation
X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger
More informationHIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY
VARIABLE GEOMETRY OVERVIEW CHARACTERISTICS APPLICATIONS KQ OVERVIEW : KQ high induction diffusers with variable geometry are a new type of air diffusion equipment. Their unique deflector adjustment system
More informationCatalog Air curtain NAC
Catalog 1.2.1 NAC NAC Model Description, areas of application and benefits............................... 1 Configuration.............................................................. 2 Operation..................................................................
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationseries 90-GV Variable geometry units
series 90-GV Variable geometry units www.koolair.com 1 S-90-GV Variable geometry unit CONTENTS Description and coding 2 Operation 3 Dimensions 4 Technical data 4 2 S-90-GV Variable geometry unit Description
More informationEAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS
Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Rotatable discs % flexible distribution pattern Cleanable Adjustable slot for enhanced capacity Simple adjustment Used together
More informationWall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL
Wall air diffusers with discs for supply air and flush mounting General Rectangular supply air diffusers with rotatable discs. The disc technique enables supply of air above or below room temperature as
More informationCeiling Slot Diffuser Model DSX
Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation
More informationFloor diffusers. The art of handling air. Type FB. In aluminium and plastic
T.3//EN/ Floor diffusers Type FB In aluminium and plastic The art of handling air Contents Description Description Installation examples 3 Construction Dimensions Plenum box Load capacity Installation
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationDisc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1
X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationDRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP
TYPE: DJA DJB DJAP DJBP APPLICATION Type DJ As with type AJ diffusers, this product is also designed to project large volumes of air over long distances, but particularly lends itself to sidewall or ductmounting,
More informationACTIVENT System. Specifications. Product code example ACTA
Activent is a ventilation system for supplying and distributing air. The system has been proven to function effectively in both small and large areas and is used in all types of premises ranging from offices
More informationCeiling diffuser 4DE
Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationLINEAR SLOT DIFFUSERS
OVERVIEW CHARACTERISTICS APPLICATIONS KL OVERVIEW : The KL series diffusers represent the best development for this type of air diffusion units. Their particular structure allows to direct the flow of
More informationFloor Swirls Models BZD and SZD
July 09 Floor Swirls Floor Swirls Models BZD and SZD Features Model BZD Circular Floor Swirl Model SZD Circular Step Diffuser Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk
More informationLINEAR SLOT DIFFUSERS
OVERVIEW CHARACTERISTICS APPLICATIONS OVERVIEW : The series linear diffusers allow to manage high air flows with minimum pressure losses and generated noise power. They allow to fully make use of the induction
More informationCeiling impulse diffuser Model PIL
Ceiling impulse diffuser Model PIL Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationC O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S CIRCULAR DIFFUSERS LRS SERIES LRS SERIES CIRCULAR DIFFUSERS L SERIES Application Colman Air Distribution L series circular swirl diffusers
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationCompact Grille Model KG
Compact grille KG Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...3
More informationTotal comfort control
Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data
More informationHIGH CAPACITY LINEAR SLOT DUFFUSERS
HIGH CAPACITY LINEAR SLOT DUFFUSERS CB SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871
More informationPURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS
Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with
More informationPRODUCT BROCHURE. Adjustable Helical Swirl Diffuser HSC-AD HSC-AD : smartemp.com
PRODUCT BROCHURE Adjustable Helical Swirl Diffuser HSC-AD smartemp.com DESCRIPTION The SMARTEMP Adjustable Helical Swirl Diffuser, type HSC-AD, produces highly inductive swirl discharge of the supply air,
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationSRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS
Ceiling mounted linear disc diffuser for supply air QUICK FACTS flexible spread pattern Facility for vertical spread Facility for simultaneous vertical/horizontal spread Large induction effect Suitable
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationOptimAir NF. Active Chilled Beam OptimAir NF. Nov
OptimAir NF Active Chilled Beam OptimAir NF Functions The OptimAir active chilled beam is a two-way induction type air-conditioningunit that is designed for integrated installation, mounted directly in
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationDATASHEET PRODUCT CODE EXAMPLE:
214 NOZZLES ECSOR DK STBZ-0 / DR DATASHEET PRODUCT FACTS Nozzle devices DK (Short Nozzle) & DR (Long Nozzle) Intended for installation in a connection box, in a duct or behind a wall Adjustable diffusion
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationPELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide
PELICANTM Wall Rectangular perforated wall air diffusers for supply air Quick facts Flexible air distribution pattern, easy to set Cleanable, removable damper Simple commissioning, fixed measurement tapping
More informationAir displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225
0,5 0,4 0,3 0,25 0,2 0,16 0,12 0,1 0,08 0,06 0,05 0,04 0,03 0,025 0,02 0,3 0,4 0,5 0,6 1 1,5 2 2,5 3 4 5 125 2 315 ir displacement diffusers - p 202 Diffusers with rotating nozzle - p 215 lum jet diffusers
More informationNozzle air diffuser DYSB
Nozzle air diffuser DYSB DYSB is a range of nozzle air diffusers with adjustable nozzles for the setting of an optional diffusion pattern, intended for ceiling installation. The devices are documented
More information2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face
2/1/EN/3 Slot Diffuser Type VSD15 with 15 mm wide diffuser face Contents Air Diffuser Discharge Characteristics (horizontal) 2 Description 3 Air Diffuser Discharge Characteristics (alternating) 3 Construction
More informationLinear Slot Diffusers Model Slot 20 & Model Slot 25
Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page
More information1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8
These technical specifications state a row of manufactured sizes and versions of whirling air outflow outlets VVDM 300, 400, 500, 600, 625 und 825 (further only outlets). It is valid for production, designing,
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationOptima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:
Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-
More informationType VSD35. Nominal length up to 1500 mm: one spigot
Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements
More informationProduct Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm
Product Data 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams 11 to 190 cfm 36CBAC Chilled beam units offer: An increase in total airflow Sensible cooling and heating options Induction
More informationC O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES
More informationCeiling diffuser 4DF
Ceiling diffuser 4DF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction...
More informationVAV TERMINAL UNITS. VVD VAV Diffusers
Introduction ASLI VAV diffusers, VVD are variable air volume diffuser for supply air in variable air volume system. In many conventional HVAC systems, multiple work spaces are controlled by a single thermostat.
More informationseries KFD-KLD Linear slot diffusers
series KFD-KLD Linear slot diffusers www.koolair.com KFD-KLD Contents Linear slot diffusers KFD Selection tables KFD Dimensions 6 Connection system Linear slot diffusers KLD 8 Selection tables KLD 0 Dimensions
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationC O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel
More informationDRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION
DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers
More informationAir Displacement Vent Units
T 1.3/5/EN/1 Air Displacement Vent Units Type QSH ISH TRO GmbH Telephone +49/28 /2 02-0 Telefax +49/28 /2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents
More informationC O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S JET DIFFUSERS DCJ SERIES DCJ SERIES DCJ SERIES JET DIFFUSERS Application Colman s DCJ jet diffuser has been designed to supply cooled
More informationFront panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option
ZSC - Halton Zen Semi-Circle Displacement ventilation unit Capacity for wide supply airflow range. Uniform supply air distribution is achieved through small perforations, providing optimal conditions in
More informationEX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.
25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register
More informationHalton Rex 600 RE6 - Adaptable active chilled beam
Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces
More informationLINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise
LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk
More informationA B. Linear cylinder diffuser LC. pag. A-52
pag. A-5 Linear cylinder diffuser LC Description Linear rotating cylinder diffuser for ceiling or wall installation. Each slot houses inside a range of cylinders, that, by rotation, allow differents launch
More informationMOTORIZED VOLUME DAMPER
MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers
More information2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m
2/18/EN/2 Air Handling Lights Type LR Recommended for use in rooms with ceiling heights of approx. 2.60... 4.00 m Contents Description Description... 2 Supply Air Construction LR-Z... 3 Extract Air Construction
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationSupply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)
DYBA is a quiet, ceiling-mounted supply air unit that consists of a nozzle diffuser, DYBH, and an insulated plenum box, ATTC. The nozzles of the diffuser produce a swirl pattern, which provides a highly
More informationceiling swirl diffuser DQJ
ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...
More information5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air
5/9.2/EN/6 Volume Flow Limiter Type VFL for insertion into air ducting The art of handling air Contents Description 3 Dimensions 3 Nomenclature 4 Technical data 4 Acoustic data 4 Installation notes 5 Order
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationSwirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8
Swirl diffuser DHV Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationFlowBar High Capacity Slot Diffuser
October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections
More informationTHB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser
Halton THB Perforated Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation either directly to ductwork or balancing plenum Detachable front panel enables the cleaning of the diffuser
More informationSERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007
PUBLICATION DIFFUSERS 8 JUNE 2007 Features Jet Air Stream Distribution. Wide Directional Adjustment. Long Throw Capability Reversible Diffuser Nozzle Provides full or reduced Jet Pattern. High Volume Capacity.
More informationRPD ROUND PLAQUE DIFFUSER
ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.
More information