Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5

Size: px
Start display at page:

Download "Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5"

Transcription

1 Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5 SHENGZHAO FURNITURE FACTORY LIANGYONG INDUSTRIAL ZONE, ZHENNAN JIUJIANG TOWN, FOSHAN CITY, GUANGDONG PROVINCE, CHINA The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description Manufacturer Country of Origin : SZ-B819 OFFICE CHAIR : SHENGZHAO FURNITURE FACTORY : CHINA Sample Receiving Date : May 26, 2017 Test Performing Date : May 26, 2017 to Jun.15, 2017 Test(s) Requested Test Result Summary Backrest Strength Test - Static - Type l and II, Backrest Strength Test - Static - Type lll and Backrest Durability Test - Cyclic - Type l of ANSI/BIFMA X (Type I, III) Summary: 1. For further details, please refer to the following page(s). Result(s) Signed for and on behalf of Shunde Branch SGS-CSTC Co., Ltd. Caming Fan Approved signatory

2 Test Report No.: SDHL FT Date: Jun.15, 2017 Page 2 of 5 TESTS AND RESULTS Test Conducted: Backrest Strength Test - Static - Type l and II, Backrest Strength Test - Static - Type lll and Backrest Durability Test - Cyclic - Type l of ANSI/BIFMA X General-Purpose Office Chairs Tests. No. of Sample: 2 piece(s) (Sample 1, 2). For more sample information and pictures, please refer to the following page. Chair Type: Type I, III. Test and Requirements 5 Backrest Strength Test - Static - Type l and II Functional Load There shall be no loss of serviceability to the chair when 667 N (150 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 70 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 70 degrees ± 10 degrees throughout the loading of the backrest Proof Load There shall be no sudden and major change in the structural integrity of the chair, loss of serviceability is acceptable, when 1001 N (225 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 70 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 70 degrees ± 10 degrees throughout the loading of the backrest. 6 Backrest Strength Test - Static - Type lll Functional Load There shall be no loss of serviceability to the chair when 667 N (150 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 90 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 90 degrees ± 10 degrees throughout the loading of the backrest Proof Load There shall be no sudden and major change in the structural integrity of the chair, loss of serviceability is acceptable, when 1001 N (225 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 90 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 90 degrees ± 10 degrees throughout the loading of the backrest. Test Results

3 Test Report No.: SDHL FT Date: Jun.15, 2017 Page 3 of 5 Test and Requirements 14 Backrest Durability Test - Cyclic - Type l A weight of 109 kg (240 lb.) shall be secured in the center of the seat. Apply a 445 N (100 lbf.) total force to the backrest at the specified position at a rate between 10 and 30 cycles per minute. For chairs with backrest widths less than or equal to 406 mm (16 in.) at the height of the loading point, apply the load to the backrest for 120,000 cycles. For chairs with backrest widths greater than 406 mm (16 in.) at the height of the loading point, apply the load to the backrest for 80,000 cycles + 20,000 cycles at the position 102 mm (4 in.) to the right of the vertical centerline + 20,000 cycles at the position 102 mm (4 in.) to the left of the vertical centerline.. There shall be no loss of serviceability. Note: With the backrest at its back stop position, apply a force that is initially 90 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 90 degrees ± 10 degrees throughout the loading of the backrest. Test Results Remark: 1. For the sample information and pictures, please refer to the following page.

4 Test Report No.: SDHL FT Date: Jun.15, 2017 Page 4 of 5 Weight: Sample #1: kg Sample #2: kg SAMPLE INFORMATION AND PICTURES Overall Dimensions: Sample #1: 760 mm L x 725 mm W x 1180~1250 mm H Sample #2: 750 mm L x 713 mm W x 960~1028 mm H Other Dimensions: Base radius, 358 mm; base weight, 2.0 kg. Sample as Received Sample #1 - View 1 Sample #1 - View 2 Sample #1 - View 3 Sample #1 - View 4

5 Test Report No.: SDHL FT Date: Jun.15, 2017 Page 5 of 5 Sample #2 - View 5 Sample #2 - View 6 Sample #2 - View 7 Sample #2 - View 8 Sample #1&2 - View 9 ***End of Report***

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5 Test Report No.: AJHL1605004946FT Date: JUN.02, 2016 Page 1 of 5 The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description OFFICE CHAIR Type/Style K-106AH

More information

Test Report No.: SDHL FT Date: May 15, 2017 Page 1 of 15

Test Report No.: SDHL FT Date: May 15, 2017 Page 1 of 15 Test Report No.: SDHL1703004564FT Date: May 15, 2017 Page 1 of 15 HERMAN MILLER NO.488, QIAN TANG JIANG RD., BEILUN, NINGBO, ZHEJIANG, 315800, P.R. CHINA The following sample(s) was / were submitted and

More information

APPLICANT: EMECO DATE: Mar 10, ELM AVE HANOVER, PA, USA

APPLICANT: EMECO DATE: Mar 10, ELM AVE HANOVER, PA, USA APPLICANT: EMECO DATE: Mar 10, 2011 805 ELM AVE HANOVER, PA, 17331 USA ATTN: MAGNUS BREITLING THIS IS TO SUPERSEDE REPORT NO. SZHH00526912 DATED SEP 20, 2010 SAMPLE DESCRIPTION: TWO (2) PIECES OF SUBMITTED

More information

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5 Test Report No.: AJD201307381 Date: NOV.05, 2013 Page: 1 of 5 HR FURNITURE CO., LTD SHANGJIABAO ECONOMICAL DEVELOPMENT ZONE, SHENGFANG TOWN, BAZHOU, HEBEI, CHINA The following sample(s) was / were submitted

More information

Test Report. Report No: BSTDG YRR-4 Date: Mar. 27, 2015 Page 1 of 7. :No.27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province

Test Report. Report No: BSTDG YRR-4 Date: Mar. 27, 2015 Page 1 of 7. :No.27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province Report No: BSTDG1503312211YRR-4 Date: Mar 27, 2015 Page 1 of 7 Applicant Address :FOSHAN BANGLISHI TRADING CO, LTD :No27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province The following sample(s)

More information

Test Report For: EMECO INDUSTRIES INC Bar Stool

Test Report For: EMECO INDUSTRIES INC Bar Stool 4700 Broadmoor SE, Suite 200 Kentwood, MI 49512 Telephone: 616-- 656-- 7401 Facsimile: 616-- 656-- 2022 www.intertek-- etlsemko.com EMECO INDUSTRIES INC P.O. No. N / A Page 1 of 18 Test Report For: EMECO

More information

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3 Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 1 of 3 HONGGE (GUANGZHOU) PAPER CO., LTD BUILDING 1, HE TAI INDUSTRY ZONE, HE TAI ROAD NO.2, HE BIAN, JIA HE TOWN, BAI YUN DISTRICT, GUANGZHOU.

More information

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6 Test Report No. AJHL1606005818FB Date: JUN.21, 2016 Page 1 of 6 HAINING JINMAO WARP KNITTING CO., LTD NO. 38 LUHONG ROAD DINGQIAO TOWN HAINING CITY ZHEJIANG CHINA The following sample(s) was / were submitted

More information

Test Report. No. SHAHG Date: 07 Nov Page 1 of 9.

Test Report. No. SHAHG Date: 07 Nov Page 1 of 9. Test Report. No. Date: 07 Nov 2016. Page 1 of 9. DO YOUR SPORTS GMBH. NOBELSTRABE 12 IN 41189 MONCHENGLADBACH-GERMANY.. The following sample(s) was/were submitted and identified on behalf of the clients

More information

Test Report. No. SHAHG Date: 11 Nov Page 1 of 7.

Test Report. No. SHAHG Date: 11 Nov Page 1 of 7. Test Report. No. Date: 11 Nov 2016. Page 1 of 7. DO YOUR SPORTS GMBH. NOBELSTRABE 12 IN 41189 MONCHENGLADBACH-GERMANY.. The following sample(s) was/were submitted and identified on behalf of the clients

More information

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units. Date: April 2, 2015 Page: 1 of 29 Test Report For: ANSI/BIFMA X5.9-2012 Storage Units FastenLink This report shall not be reproduced, except in full, without written permission from OFS Brands Quality

More information

Contact person Date Reference Page Ulf Lemke F027196A 1 (4) Wood Technology

Contact person Date Reference Page Ulf Lemke F027196A 1 (4) Wood Technology issued by an Accredited Testing Laboratory Contact person Ulf Lemke 2014-01-22 3F027196A 1 (4) Wood Technology +46 10 516 50 32 ulf.lemke@sp.se 1002 ISO/IEC 17025 Nordic Comfort Products A/S P.O. Box 3

More information

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5 Test Report AJHL1603002392FB Date: APR.06, 2016 Page 1 of 5 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s)

More information

FEDERAL STANDARD PERFORMANCE TEST METHOD FOR INTENSIVE USE CHAIRS

FEDERAL STANDARD PERFORMANCE TEST METHOD FOR INTENSIVE USE CHAIRS METRIC November 20, 2007 SUPERSEDING FNEW-83-269E October 31, 1989 FEDERAL STANDARD PERFORMANCE TEST METHOD FOR INTENSIVE USE CHAIRS The General Services Administration has authorized the use of this federal

More information

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6 Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 1 of 6 IGEPA GROUP GmbH & CO., KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was / were submitted and identified on behalf of the

More information

Test Report. No. NGBHG Date: 28 Jun Page 1 of 6.

Test Report. No. NGBHG Date: 28 Jun Page 1 of 6. Test Report. No. NGBHG1301093401 Date: 28 Jun 2013. Page 1 of 6. NINGBO HAIHUAN RUBBER INDUSTRY CO., LTD. SOUTH ROAD NO.183,XIDIAN TOWN,NINGHAI,NINGBO,CHINA.. The following sample(s) was/were submitted

More information

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6 Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 1 of 6 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s)

More information

FOSHAN SHUNDE HEXIN ELECTRON CO.,LTD

FOSHAN SHUNDE HEXIN ELECTRON CO.,LTD FOSHAN SHUNDE HEXIN ELECTRON CO.,LTD Metallized Polypropylene Film Capcitor Model Operating temperature Range Rated voltage Application Confirmity certification CBB65-40 ~+105 4μF~120μF 110~600VAC Home

More information

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5 Page: 1 of 5 IGEPA GROUP GMBH & CO. KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S PREMIUM MESH

More information

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5 Page: 1 of 5 IGEPA GROUP GMBH & CO.KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S FRONTLIT 510

More information

General-Purpose Office Chairs - Tests

General-Purpose Office Chairs - Tests Canvass Draft The Industry Voice for Workplace Solutions Proposed American National Standard for Office Furniture General-Purpose Office Chairs - Tests 17Nov09 Sponsor BIFMA International 678 Front Avenue

More information

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12 Test Report No.: SHHG1211042519BC Date: JAN.31,2013 Page: 1 of 12 GOLDEN MOTOR TECHNOLOGY CO., LTD BLOCK 8, MODERN INDUSTRIAL CENTER, 801 CHANGWU MIDDLE ROAD, CHANGZHOU, JIANGSU, CHINA 213164 The following

More information

Contact person Date Reference Page Michael Lindblad F025884B 1 (1) Sustainable Built Environment

Contact person Date Reference Page Michael Lindblad F025884B 1 (1) Sustainable Built Environment issued by an Accredited Testing Laboratory Contact person Michael Lindblad 2015-05-09 5F025884B 1 (1) Sustainable Built Environment +46 10 516 58 58 Michael.Lindblad@sp.se Accred. No. 1002 Testing ISO/IEC

More information

TEST REPORT N

TEST REPORT N centro ricerche-sviluppo Date received: 05-10-10 Date of issue: 25-11-10 Report consists of 10 attached sheets. Defects before testing: one Sample name: SHIY 121264 Overall dimensions: 750 x 750 x 1060

More information

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-112R Extension number: 00

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-112R Extension number: 00 Vehicle Technology Division THE NETHERLANDS (N E D E R L A N D) COMMUNICATION Concerning (1) - approval granted - approval extended - approval refused - approval withdrawn - production definitely discontinued

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 2528 Cathy Ln Jasper, IN Brian Truelove Phone: MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 2528 Cathy Ln Jasper, IN Brian Truelove Phone: MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 UL 2528 Cathy Ln Jasper, IN 47546 Brian Truelove Phone: 812 556 5094 MECHANICAL Valid To: July 31, 2018 Certificate Number: 2709.03 In recognition of the successful

More information

Contact person Date Reference Page Michael Lindblad F025884A 1 (1) Sustainable Built Environment

Contact person Date Reference Page Michael Lindblad F025884A 1 (1) Sustainable Built Environment issued by an Accredited Testing Laboratory Contact person Michael Lindblad 2015-05-09 5F025884A 1 (1) Sustainable Built Environment +46 10 516 58 58 Michael.Lindblad@sp.se Accred. No. 1002 Testing ISO/IEC

More information

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10 Test Report : SZTY1211030991TS Date: DEC 04, 2012 Page 1 of 10 HAPPY ARTS&CRAFTS(NINGBO)CO.,LTD/ HAPE INTERNATIONAL(NINGBO)LTD 9-27 NANHAI ROAD, DAGANG INDUSTRIAL CITY, BEILUN, NINGBO, CHINA PC:315800

More information

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-23R Extension number: 00

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-23R Extension number: 00 Vehicle Technology Division THE NETHERLANDS (N E D E R L A N D) COMMUNICATION Concerning (1) : - approval granted - approval extended - approval refused - approval withdrawn - production definitely discontinued

More information

TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb)

TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb) TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb) REFERENCED DOCUMENTS ISO7176-1:1999, ISO7176-3:2003, ISO7176-5:2008 ISO7176-7:1998, ISO7178-8:1998, ISO7176-13:1989, ISO7176-15:1996,

More information

Test Report. TIANJIN TOYO INK CO.,LTD.. 12XINGHUA2#ROAD XIQING ECONOMIC DEVELOPMENT AREA,TIANJIN , CHINA.

Test Report. TIANJIN TOYO INK CO.,LTD.. 12XINGHUA2#ROAD XIQING ECONOMIC DEVELOPMENT AREA,TIANJIN , CHINA. Test Report. No. TSNEC1500174842 A01 Date: 05 Mar 2015. Page 1 of 8. TIANJIN TOYO INK CO.,LTD.. 12XINGHUA2#ROAD XIQING ECONOMIC DEVELOPMENT AREA,TIANJIN 300385, CHINA. This report is to supersede test

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 3480 Windquest Drive Holland, MI Dan Kolean Phone: MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 3480 Windquest Drive Holland, MI Dan Kolean Phone: MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 UL 3480 Windquest Drive Holland, MI 49424 Dan Kolean Phone: 616 928 0791 MECHANICAL Valid To: July 31, 2018 Certificate Number: 2709.01 In recognition of the

More information

Seth Setzer Submit Samples to: Phone: Ext.

Seth Setzer Submit Samples to: Phone: Ext. Seth Setzer Submit Samples to: Phone: 828-327-7000 Ext. 4449 Manufacturing Solutions Center ssetzer@manufacturingsolutionscenter.org 301 Conover Station SE Conover NC 28613 Cody Whitener Structural Testing

More information

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6 Test Report. AJHL1610011324FB-2 Date: OCT.24, 2016 Page 1 of 6 POSTER AND PANEL CPERE ANDORRA, SN, POL. IND, ILLA,SUD, NAUS, 4, 5, I6,08650, SALLENT, BARCELONA, SPAIN The following sample(s) was were submitted

More information

Instruction Manual for LED Underwater Light HT008C-P-T

Instruction Manual for LED Underwater Light HT008C-P-T Instruction Manual for LED Underwater Light HT008C-P-T IMPORTANT: This manual includes essential information on the safety measures to be implemented for installation and start-up. Therefore, the installer,

More information

Test Report No: EEC18/01 dated August 02, 2018

Test Report No: EEC18/01 dated August 02, 2018 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is

More information

: Metta Company : FLTSSP _07. : Swiss Approval Furniture Laboratory. : Elefsis, Attica Greece

: Metta Company : FLTSSP _07. : Swiss Approval Furniture Laboratory. : Elefsis, Attica Greece Holder Manufacturer : Metta Company : Metta Company Test Item : Office work chair model SAMURAI S-1 Identification : FLTSSP-161118_07 Condition of delivery : Date of delivery : 18/11/2016 Testing laboratory

More information

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY THE UNITED KINGDOM TYPE APPROVAL AUTHORITY Dear Sir / Madam, Date: 02 November 2015 1. The vehicle component / type described on the attached approval(s) has been tested and meets the requirements of the

More information

Test Report. No. SHAHG Date: 12 Dec Page 1 of 7.

Test Report. No. SHAHG Date: 12 Dec Page 1 of 7. Test Report No SHAHG1624457402 Date: 12 Dec 2016 Page 1 of 7 #DOYOURSPORTS GMBH NOBELSTRAßE 12 IN 41189 MÖNCHENGLADBACH-GERMANY The following sample(s) was/were submitted and identified on behalf of the

More information

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N Report consists of 7 test reports. CERATOLA S.P.A. VIA GIORGIOE 2-ZOA ID.LE 31037 RAMO DI LORIA (TV) Defects before testing: one Sample name: COZY swivel chair SAMPLE 180511 Overall dimensions: 660 x 660

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

Instruction Manual for Resin Filled LED Underwater Light

Instruction Manual for Resin Filled LED Underwater Light Instruction Manual for Resin Filled LED Underwater Light Model No.: HT001C-P-T, HT002C-P-T HT003C-P-T, HT005C-P-T, HT006C-P-T IMPORTANT: This manual includes essential information on the safety measures

More information

Test Report. No. SHAHG A01 Date: 10 May Page 1 of 6.

Test Report. No. SHAHG A01 Date: 10 May Page 1 of 6. Test Report No Date: 10 May 2010 Page 1 of 6 NINGBO VINKOE IUSTRY CO,LTD 4225,48 KARAT,NO1388 TIANTONG NORTH RD,YINZHOU 315100,NINGBO CITY,CHINA THIS REPORT IS TO SUPERSEDE TEST REPORT NOSHAHG1005423201,

More information

TEST REPORT FOR: Product Design Group Inc. Elevation Manual Wheelchair 115 kg, 253 lb

TEST REPORT FOR: Product Design Group Inc. Elevation Manual Wheelchair 115 kg, 253 lb TEST REPORT FOR: Product Design Group Inc. Elevation Manual Wheelchair 115 kg, 253 lb REFERENCED DOCUMENTS ISO7176-1:1999, ISO7176-3:2003, ISO7176-5:2008, ISO7176-7:1998, ISO7176-8:1998, ISO7176-13:1989

More information

NovitaTech Engineering

NovitaTech Engineering NovitaTech Engineering 490869 TEST REPORT FOR PDG Product Design Group Eclipse 600 MANUAL WHEELCHAIR TEST DOCUMENTS AS3695:1992, AS3696-1:1990, AS 3696-3:1990, AS 3696-5:1989, AS 3696-8:1998, ISO 7176-7:1996

More information

Test Report No.: SHHG MD Date: FEB. 26, 2016 Page: 1 of 17

Test Report No.: SHHG MD Date: FEB. 26, 2016 Page: 1 of 17 Report No.: SHHG1508032551MD Date: FEB. 26, 2016 Page: 1 of 17 GOLDEN MOTOR TECHNOLOGY CO., LTD. BLOCK 8,MODERN INDUSTRIAL CENTER,801 CHANGWU MIDDLE ROAD, CHANGZHOU, JIANGSU, 213164, CHINA The following

More information

Internrapport

Internrapport page 1/5 and Verification Center Internrapport 17-10182 Article: requested by: Jan Jismyr Materia AB Tranås Sweden s are carried out according to standard: Discrepancies: Result and observations:, test

More information

Contact person Date Reference Page Ulf Lemke F015337C 1 (4) Wood Technology

Contact person Date Reference Page Ulf Lemke F015337C 1 (4) Wood Technology issued by an Accredited Testing Laboratory Contact person Ulf Lemke 2013-08-12 3F015337C 1 (4) Wood Technology +46 10 516 50 32 ulf.lemke@sp.se 1002 ISO/IEC 17025 Johanson Design AB Anders Anderssons väg

More information

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N Report consists of 11 test reports. Defects before testing: one Sample name: RELOAD chair SAMPLE 213402 Overall dimensions: 580 x 560 x 790 (h) mm List performed tests: 1. Safety requirements E 16139:2013+AC:2013

More information

STADIUM. Seating Products

STADIUM. Seating Products STADIUM Seating Products 02 Seating Excellence at Work Merryfair s outdoor stadium seating collection. Durable seating available in vibrant colours. Discover the Sporta, Ola, Oahu. 03 04 Comfort The tip-up

More information

Contact person Date Reference Page Hans Eriksson F000838G 1 (4) Wood Technology

Contact person Date Reference Page Hans Eriksson F000838G 1 (4) Wood Technology issued by an Accredited Testing Laboratory Contact person Hans Eriksson 2015-03-26 5F000838G 1 (4) Wood Technology +46 10 516 54 28 hans.eriksson@sp.se 1002 ISO/IEC 17025 Nordic Comfort Products A/S P.O.

More information

page 1/5 EN 16139:2013, test severity level 1 Manager Kinnarps Test- & verification Center

page 1/5 EN 16139:2013, test severity level 1 Manager Kinnarps Test- & verification Center page 1/5 and Verification Center Article: requested by: Jan Jismyr Materi AB Tranås Sweden s are carried out according to standard: Discrepancies: Result and observations:, test severity level 1 This European

More information

Contact person Date Reference Page Michael Lindblad F000833F 1 (1) Sustainable Built Environment

Contact person Date Reference Page Michael Lindblad F000833F 1 (1) Sustainable Built Environment issued by an Accredited Testing Laboratory Contact person Michael Lindblad 2015-06-25 5F000833F 1 (1) Sustainable Built Environment +46 10 516 58 58 Michael.Lindblad@sp.se 1002 ISO/IEC 17025 Martela AB

More information

Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa.

Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa. Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa. OUR COLOURS PLEASE NOTE: Even though the colour palette above has

More information

David Fagan, Mobility Manager Paragon Mobility Pty Ltd 3/10 Tapnor Crescent, Brendale, Queensland th December, 2011.

David Fagan, Mobility Manager Paragon Mobility Pty Ltd 3/10 Tapnor Crescent, Brendale, Queensland th December, 2011. David Fagan, Mobility Manager Paragon Mobility Pty Ltd 3/10 Tapnor Crescent, Brendale, Queensland. 4500 15 th December, 2011 Dear David, Reference: testing the Catalyst Spark manual wheelchair to 77 kg

More information

Full extension concealed slide with soft closing and self-closing

Full extension concealed slide with soft closing and self-closing Orderer / Customer: Grass-Hopper (HongKong) Limited 7 th Floor, Allied Kajima Building, 138 Gloucester Road, WanChai, Hong Kong Object / Test specimen: Model no.: Full extension concealed slide with soft

More information

page 1/6 EN 16139:2013, test severity level 1 The sample submitted for test fulfils the requirements in above mentioned standards.

page 1/6 EN 16139:2013, test severity level 1 The sample submitted for test fulfils the requirements in above mentioned standards. page 1/6 and Verification Center Article: requested by: Neolite, armrests sledge Jan Jismyr Material AB Tranås Sweden s are carried out according to standard: Discrepancies: Result and observations: EN

More information

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder. ALICATION FOR CONSTRUCTION RODUCTS DIRECTIVE On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder Model No: 385T repared For : repared By : Shenzhen Changen Industry Co.,Ltd.

More information

Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa.

Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa. Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa. OUR COLOURS PLEASE NOTE: Even though the colour palette above has

More information

Verplas Self-Seal Coupling Leakage Test. Prepared for : Verplas Limited. 25 February Test report number Page 1 of 11

Verplas Self-Seal Coupling Leakage Test. Prepared for : Verplas Limited. 25 February Test report number Page 1 of 11 Verplas Self-Seal Coupling Leakage Test Prepared for : Verplas Limited 25 February 2013 Page 1 of 11 Prepared by Name M Swainson Position Principal Engineer Date 25 th February 2013 Signature Approved

More information

Seating Excellence at Work

Seating Excellence at Work Products News Contact Seating Excellence at Work Merryfair was established in 1974 to manufacture component parts and sooner ventured into making office chairs in 1982. We soon became a leading office

More information

TEST REPORT. Version:V1.0 Page 1 of 9. Client company : Berdis Lighting Co., LTD.

TEST REPORT. Version:V1.0 Page 1 of 9. Client company : Berdis Lighting Co., LTD. TEST REPORT Client company : Berdis Lighting Co., LTD. Client address : 6F, No.1, South 2nd Lane, HuaTai East Road, Caosan Industrial Park, Guzhen Town, Zhongshan City, Guangdong Province, China Report

More information

Contact person Date Reference Page Michael Lindblad F013838C 1 (1) Sustainable Built Environment

Contact person Date Reference Page Michael Lindblad F013838C 1 (1) Sustainable Built Environment issued by an Accredited Testing Laboratory Contact person Michael Lindblad 2015-09-17 5F013838C 1 (1) Sustainable Built Environment +46 10 516 58 58 Michael.Lindblad@sp.se 1002 ISO/IEC 17025 Johanson Design

More information

Test Report No. GZTXO TX Date: Jun 30, 2008 Page 1 of 6

Test Report No. GZTXO TX Date: Jun 30, 2008 Page 1 of 6 Test Report No. GZTXO080618073TX Date: Jun 30, 2008 Page 1 of 6 NEW VALUE PARTNER GROUP LIITED FLAT 3, 6/F SHUN HONG HOUSE SHUN CHI COURT KWUN TONG HONG KONG This report supersedes our previous report

More information

Sealed Lead Acid Battery STANDBY APPLICATIONS. Premium Brand of Flying Power Group. Certified by

Sealed Lead Acid Battery STANDBY APPLICATIONS. Premium Brand of Flying Power Group. Certified by Sealed Lead Acid Battery STANDBY APPLICATIONS Premium Brand of Flying Power Group Certified by New factory picture - completed by 2016, covering 300,000 m 2 COMPANY PROFILE Genergy Battery Co. Limited

More information

Test Report. No. SHAEC Date: 15 Jul Page 1 of 5.

Test Report. No. SHAEC Date: 15 Jul Page 1 of 5. Test Report. No. SHAEC1614522103 Date: 15 Jul 2016. Page 1 of 5. Taian Fibtex Trade Co., Ltd.. Rm.1701,Tianlong International Bldg., 96 Great Wall Rd., Tai`an City, Shandong 271000, China.. The following

More information

SYNCHRON. Seating Products

SYNCHRON. Seating Products SYNCHRON Seating Products Synchron Series Synchron series is an enlightened choice for executives, professionals and managers. Fine leather upholstery and majestic designs make it extraordinary and suitable

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

WAU. Seating Products

WAU. Seating Products WAU Seating Products Sports Design Concept 02 Wau combines excellent ergonomics to extract human performance and trendy styling to elicit self confidence and satisfaction as you perform. 04 05 Wau Recline-Glide

More information

Test Report No.: SDHL FT Date: Aug.16, 2017 Page 1 of 47

Test Report No.: SDHL FT Date: Aug.16, 2017 Page 1 of 47 Test Report No.: SDHL1707015823FT Date: Aug.16, 2017 Page 1 of 47 EUREKA LLC 4901 MOREAU CT, EL DORADO HILLS, CA 95762 The following sample(s) was / were submitted and identified on behalf of the client

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000785-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 11408 lm 112.1 W 101.8 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL

More information

VIDA. Goole. Tel. +44 (0) EC1M 4NQ. Tel. +44 (0)

VIDA. Goole. Tel. +44 (0) EC1M 4NQ. Tel. +44 (0) VIDA Goole Tel. +44 (0)140 746000 EC1M 4NQ Tel. +44 (0)20 7490 4909 Design The English translation of the Spanish word Vida - 1 2 User Controls Vida s design is clean, crisp and uncluttered. All of the

More information

SILVER SURF. Sitool. Seating Products

SILVER SURF. Sitool. Seating Products SILVER SURF Sitool Seating Products 02 Design Silver Surf resembles an extremely long surf board in a surreal metalic finish, propped on two thin legs in an equally surreal floating appearance. Its fascinating

More information

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Feb 24, 2017 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Feb 24, 2017 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Feb 24, 2017 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA Attn: MS MA Sample Description: Forty-six (46) styles

More information

10-Feb-14. VCA job number: CSP Date: 10 February Dear Sirs,

10-Feb-14. VCA job number: CSP Date: 10 February Dear Sirs, VCA job number: CSP286498 Date: 10 February 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC

More information

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82 age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang

More information

KSQ9001:2009/ISO9001:2008 A-RYUNG. AR2013-ATP-EK1

KSQ9001:2009/ISO9001:2008 A-RYUNG.   AR2013-ATP-EK1 KSQ9001:2009/ISO9001:2008 A-RYUNG www.aryung.co.kr AR2013-ATP-EK1 T-ROTOR OIL PUMPS CONTENTS 2 8 9 10 11 14 16 18 20 22 24 26 27 28 30 32 34 37 Technical data T-ROTOR pumps AR1-F Series AR2-FC Sreies ATP-S

More information

Test Report. No. SHAEC Date: 23 Apr Page 1 of 5.

Test Report. No. SHAEC Date: 23 Apr Page 1 of 5. Test Report No SHAEC1806467803 Date: 23 Apr 2018 Page 1 of 5 DONGJUE SILICONE(NANJING)CO,LTD NO196 FUYIN ST(E),QIAOLIN,PUKOU DISTRICT,NANJING CITY,JIANGSU PROVINCE,CHINA The following sample(s) was/were

More information

Sayl Chairs. Published September Work Chair. Side Chair. Stool Herman Miller, Inc., Zeeland, Michigan

Sayl Chairs. Published September Work Chair. Side Chair. Stool Herman Miller, Inc., Zeeland, Michigan Technical Specifications Published September 2015 Work Chair Performance Information 2 Methodology and Dimension Description 3 ing Measurements 4 Work Chair 16 Side Chair Performance Information 19 Methodology

More information

Sola. 290 range. Digital-brochure-290-Sola-02-SR

Sola. 290 range. Digital-brochure-290-Sola-02-SR Digital-brochure-290-Sola-02-SR-170830-1144 (1/3) Sola. A distinctive frame. A chair that rocks. And that s perfectly crafted. The Sola conference chair echoes the Wilkhahn tradition of combining inno

More information

TEST REPORT. Automobile Parts Test Center (Guangzhou) Car Care Products (Oil System Cleaner, Oil System Care, Fuel System Cleaner) Commissioned Test

TEST REPORT. Automobile Parts Test Center (Guangzhou) Car Care Products (Oil System Cleaner, Oil System Care, Fuel System Cleaner) Commissioned Test Ref. No. 2008-H-06 Total Pages 26 TEST REPORT Product Name: Car Care Products (Oil System Cleaner, Type: Oil System Care, Fuel System Cleaner) Test Category: Client: Send Date: Commissioned Test PERFECT(CHINA)CO.,LTD.

More information

Type: Office work chair Lab.no.: Depth: 650 mm Width: 710 mm Height: 1345 mm Weight: 18,8 kg. EN :2009 and EN :2009.

Type: Office work chair Lab.no.: Depth: 650 mm Width: 710 mm Height: 1345 mm Weight: 18,8 kg. EN :2009 and EN :2009. Lanab Design Aktiebolag Attn.: Åke Jansson Lerbacksgatan 7 SE-571 38 NÄSSJÖ Order no. 515628 Appendices 3 Initials laha/prni/hbs Report Material: Model: LD6340/LD6240 Type: Office work chair Lab.no.: 515628-2

More information

SINGLE VOLTAGE EXTERNAL POWER SUPPLY TEST REPORT

SINGLE VOLTAGE EXTERNAL POWER SUPPLY TEST REPORT SINGLE VOLTAGE EXTERNAL POWER SUPPLY TEST REPORT Prepared For : Product Name: PEAK ELECTRONIC(HUIZHOU)CO., LTD Add: No.1, Xialuo Road, Zhongkai Hi-tech Area, Huizhou, Guangdong, China DAB/FM radio Trade

More information

QB/T Translated English of Chinese Standard: QB/T

QB/T Translated English of Chinese Standard: QB/T Translated English of Chinese Standard: QB/T2858-2007 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL LIGHT INDUSTRY STANDARD QB OF THE PEOPLE S REPUBLIC OF CHINA ICS 97 180 Y 50 Reference No.

More information

Type: Office work chair Lab.no.: A. EN :2009 Office furniture - Office work chair - Part 2: Safety requirements.

Type: Office work chair Lab.no.: A. EN :2009 Office furniture - Office work chair - Part 2: Safety requirements. Labofa Stole A/S Attn.: Finn Pedersen Borgergade 42 DK-4241 Vemmelev Order no. 434372 Appendices 3 Initials laha/prni/hbs Report Material: Model: Five star office chairs from the series EGO Plus, EGO BASIS,

More information

Contact person Date Reference Page Hans Eriksson F000838D 1 (3) Wood Technology

Contact person Date Reference Page Hans Eriksson F000838D 1 (3) Wood Technology issued by an Accredited Testing Laboratory Contact person Hans Eriksson 2015-03-26 5F000838D 1 (3) Wood Technology +46 516 54 28 hans.eriksson@sp.se 02 ISO/IEC 17025 Nordic Comfort Products A/S P.O. Box

More information

- Name & Address Of Buyer: AL-LAMAA PALACE TRAD EST. Add: exit-18 new sulai industrial area riyadh-saudi arabia

- Name & Address Of Buyer: AL-LAMAA PALACE TRAD EST. Add: exit-18 new sulai industrial area riyadh-saudi arabia Inspection Order No. : IN-TJ-5802-14320 BOSS No: TBA Page No. : 1 of 7 Date of issue: Nov.26th, 2014 INSPECTION REPORT (non-negotiable) - Description and Quantity of Rectangle Tube, SS 316 L Angle,SS316

More information

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Jul 09, 2016 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Jul 09, 2016 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Jul 09, 2016 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA Attn: MS LIN This is to supersede Report No. GZHH00204430

More information

V1000 / V2000 / V5000 Intelligent Efficient Reliable Affordable

V1000 / V2000 / V5000 Intelligent Efficient Reliable Affordable V1000 / V2000 / V5000 Zhuhai Siger Medical Equipment Co., Ltd Add: Building 2, No.1 Chuangxin Yi Road, Tangjiawan Town, Zhuhai City, Guangdong Province, P. R. China. Tel: +86-756 3881060 Fax: +86-756 3881028

More information

T~$t P~Cijpt1oll ', je~t# ' ~n~:2{211rtadje.sampje. PREPARED FOR: Comfor Tek Seating Street North Lethbridge, AB

T~$t P~Cijpt1oll ', je~t# ' ~n~:2{211rtadje.sampje. PREPARED FOR: Comfor Tek Seating Street North Lethbridge, AB ... PREPARED FOR: Comfor Tek Seating 1410-39 Street North Lethbridge, AB Systems & Services, Inc. TEST REPORT Test No: T11661 P.O. NO.: 209192 Start Date: 7/15/16 End Date: 8/2/16 Report Date: 8/3/2016

More information

page 1/5 EN 16139:2013, test severity level 1

page 1/5 EN 16139:2013, test severity level 1 page 1/5 and Verification Center Article: requested by: Jan Jismyr Material AB Tranås Sweden s are carried out according to standard: Discrepancies: Result and observations: EN 16139:2013, test severity

More information

Certificate of testing

Certificate of testing 4640 Faxe. Denmark Page 1 of 6 Certificate of testing Crash Test according to ISO 10542-5 & ISO 7176-19 - 2012 Wheelchair tiedown and occupant-restraint systems. Systems for specific wheelchairs This report

More information

Technical Report No D Dated

Technical Report No D Dated Client: Innokin Technology Co.,Ltd Address: Attn.: Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing street,shenzhen, China George Sample Description: itaste 134 MX-M Model No.: / Contury of

More information

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N 33048 S. Giovanni al at. UD Date received: 30/04/15 Date of issue: 16/06/15 Report consists of 11 test reports. METALMECCAICA ALBA S.R.L. 31020 SA ZEOE DEGLI EZZELII (TV) Defects before testing: one Sample

More information

14 SEER Condensing Units

14 SEER Condensing Units Condensing Units 1-1/2-5 Ton R410A Here s an ideal combination of energy efficiency and easy service Standard Features R-410A chlorine-free refrigerant Compressor Sound Blanket Internally protection against

More information

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax Date received: 11/07/14 Date of issue: 02/09/14 CERATOLA S.P.A. VIA GIORGIOE 2-ZOA ID.LE 31037 RAMO DI LORIA (TV) Report consists of 11 test reports. Defects before testing: one Sample name: REVOLUTIO

More information

Caper Chairs 1 Technical Specifications. Caper Chairs

Caper Chairs 1 Technical Specifications. Caper Chairs Caper Chairs 1 Technical Specifications Caper Chairs Caper Chairs 2 Performance Information Performance Information 3 Methodology and Dimension Description 4 ing Measurements 6 Multipurpose Chair 10 Stacking

More information

MANUFACTURER : FLASHBAY ELECTRONICS BLGD B&C XI FENG CHENG IND ZONE, NO. 2 FUYUAN ROAD HE PING, VILLAGE, FUYONG TOWN, SHENZHEN

MANUFACTURER : FLASHBAY ELECTRONICS BLGD B&C XI FENG CHENG IND ZONE, NO. 2 FUYUAN ROAD HE PING, VILLAGE, FUYONG TOWN, SHENZHEN TEST REPORT LAB NO. : (9317)097-0679-R1 PAGE : 1 OF 13 The report is amendment of and supersedes the previous report (9317)097-0679 dated Apr 26, 2017 APPLICANT : FLASHBAY ELECTRONICS BLGD B&C XI FENG

More information

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N Report consists of 9 test reports. ARDI S.P.A. VIA ARSO 4 36072 CHIAMPO (VI) Defects before testing: one Sample name: OMEGA SAMPLE 194871 Overall dimensions: 690 x 1700 x 900 (h) mm List performed tests:

More information

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of Nanjing Feeling Rubber & Plastic Produces Co., Ltd EPDM Rubber Granule Prepared For : Nanjing Feeling Rubber & Plastic Produces Co., Ltd QIAOLIN INDUSTRIAL

More information