SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION FEATURES

Size: px
Start display at page:

Download "SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION FEATURES"

Transcription

1 530.TGY (95) SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DEG/DEE090, & DEG/DEE 7/, AND / NOMINAL TONS EER SUNLINE PLUS DESCRIPTION YORK Sunline PLUS units are convertible single packages with a common footprint cabinet and common roof curb for all models. All units have dual compressors and dual independent refrigeration circuits. They provide high efficiency cooling and can be equipped with either gas heat or electric heat. The units were designed for light commercial applications and can easily be installed on a roof curb, slab, roof jack or frame. All units are selfcontained and assembled on rigid full perimeter base rails allowing for 3way fork lift access and overhead rigging. Every unit is completely charged, wired, piped and tested at the factory to provide for a quick and easy field installation. Both down and side discharge airflows are available without having to swap panels. The installer simply removes the duct covers for the desired configuration. Economizers may be used on either side or down discharge applications with no modifications required. All units have long lasting powder paint cabinets with 7 hour salt spray test approval under ASTMB7 procedures. All models include a year limited warranty on the complete unit. Compressors and electric heating elements carry an additional year warranty. Aluminized steel tubular heat exchangers carry an additional 9year warranty. FEATURES COMMON FOOTPRINT / COMMON CABINET All model sizes share the exact same footprint cabinet and therefore the same roof curb. You now have the flexibility of setting one curb and, after the internal load has been determined, placing the proper tonnage unit on that curb. HIGH EFFICIENCY All units have a minimum EER of 9.3. Gas/electric models have electronic spark ignition and power vented combustion with a minimum Steady State Efficiencies of 0%. These efficiencies exceed all legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / return is desired, you simply remove the two bottom duct covers and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. FACTORY INSTALLED OPTIONS Economizers and alternate indoor fan motors can be installed at the factory. The economizers are shipped installed and wired. Only the outdoor air hood needs to be field assembled and installed. PHENOLIC COATED CONDENSER COIL Special coating process that utilizes "Technicoat " processes. Coating is applied by total immersion of the complete coil for maximum protection. FIELD INSTALLED ACCESSORIES Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. The " high roof curb is shipped knocked down. The roof curb has an insulated deck. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0 F. Propane and high altitude kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR AIRFLOWS Indoor fan motors are beltdrive type providing maximum flexibility to handle all airflow requirements. Factoryinstalled alternate indoor fan motors are available on some models for high static applications. A fixed outdoor air damper with rain hood is standard on all units. It must be fieldinstalled on either the return air duct cover for bottom air applications or on the return air ductwork for side air applications. The damper can be adjusted to allow up to 5% outdoor air to enter the unit s return air section. This same damper assembly can be used for barometric relief on units with economizer. FULL PERIMETER BASE RAILS The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. Cont d.

2 530.TGY FEATURES CONT D. UTILITY CONNECTIONS MADE EASY Gas and electric utility knockouts are provided in the bottom as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT A low voltage printed circuit board contains a low voltage terminal strip. An additional set of pin connectors is also provided so that field interface of external controls will be simplified. The electrical control box is not located in the compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures. AIR FILTERS Units come standard with " throwaway filters. The unit filter racks can accommodate " or " filters without any modifications. SYSTEM PROTECTION Internal overload protection and crankcase heat are standard on all compressors. Each refrigeration circuit has a liquid line filterdrier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. The units will operate down to 5 F without any additional low ambient controls. SUNLINE PLUS LONG LASTING POWDER PAINT FINISH ASTMB7 CERTIFIED WITH POST PURGE FULL PERIMETERBASE RAILS WITH FORKLIFT SLOTS AND LIFTING HOLES TABLE OF CONTENTS Description... Features... Ratings...3 Physical Data...3 Cooling Capacities... Blower Performance...9 Blower Motor and Drive Data...9 Field Wiring...9 Electrical Data... Accessory Static Resistances... Component Weights... Electrical Data Electric Heaters... Unit Dimensions... 3 Typical RoofTop Installation... Roof Curb Dimensions... 5 Typical Applications... 5 Options and Accessories... Unitary Products Group

3 530.TGY RATINGS CAPACITY RATINGS Cooling / Electric Heating MODEL ARI RATINGS COOLING CAPACITY 0 / 795 F MBH EER IPLV SOUND RATING 3 (bels) NOMINAL ELECTRIC HEAT CAPACITY (KW) DEE ,,, 3 DEE ,, 3, 5 DEE ,, 3, 5 CAPACITY RATINGS Cooling / Gas Heating ARI RATINGS MODEL COOLING CAPACITY 0 / 795 F MBH EER IPLV DEG090N DEG090N DEGN5.0.0 DEGN DEGN DEGN NOTE: All units are twostage gas heating. First stage is % of total. Rated in accordance with ARI Standard. Rated in accordance with ARI Standard Sound ratings are in accordance with ARI Standard. SOUND RATING 3 (bels) INPUT (MBH) OUTPUT (MBH) GAS HEAT CAPACITY S.S.E. (%) S.E. (%) TEMP. RISE ( F) GAS LINE SIZE (in. OD) 3/ 3/ 3/ 3/ 3/ 3/ EER = Energy Efficiency Ratio the cooling capacity in BTU s per hour (BTUH) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). S.S.E. = Steady State Efficiency. (Percent Output). S.E. = California Seasonal Efficiency determined in accordance with test procedures as specified by the State of California Energy Commission. PHYSICAL DATA BASIC UNITS EVAPORATOR EVAPORATOR COIL CONDENSER FANS (Two Per Unit) CONDENSER COILS (Two Per Unit) AIR FILTERS (SEE NOTE) SYSTEM CHARGE *Standard on DEG090 NOTE: Filter racks are adapted for " or " thick filters. MODELS DEG/DEE DEG/DEE 090 CENTRIFUGAL (Dia. x Wd. in.) x 5 x 5 X FAN MOTOR HP (STANDARD) / 3 FAN MOTOR HP (ALTERNATE) * 3 5 ROWS DEEP 3 FINS PER INCH FACE AREA (Sq. Ft.) PROPELLER DIA. (in.) (Each) FAN MOTOR HP (Each) / / 3/ NOM. (Each) ROWS DEEP (Each) 3 3 FINS PER INCH (Each) 3 3 FACE AREA (Sq. Ft.) (Total) QUANTITY PER UNIT (" x " x ") QUANTITY PER UNIT (" X " X ") 3 QUANTITY PER UNIT (" X " X ") TOTAL FACE AREA (sq. ft.) REFRIGERANT SYSTEM NO. 9/0 / / (lbs./oz.) SYSTEM NO. 9/0 / 3/0 Unitary Products Group 3

4 530.TGY COOLING CAPACITIES 7/ TON (DEG/DEE090) Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Total Power Sensible Capacity, MBH Total Power Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW MBH KW Air On Temperature of Air on Condenser Coil Evaporator 5 F 5 F Coil Total Power Sensible Capacity, MBH Total Power Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW MBH KW These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.5 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total KW) and the compressor motors but not the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group

5 COOLING CAPACITIES TON (DEG/DEE) Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Total Power Sensible Capacity, MBH Total Power Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW MBH KW Air On Temperature of Air on Condenser Coil Evaporator 5 F 5 F Coil Total Power Sensible Capacity, MBH Total Power Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW MBH KW These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.5 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total KW) and the compressor motors but not the supply air blower motor. 530.TGY NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 5

6 530.TGY COOLING CAPACITIES / TON (DEG/DEE) Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Total Power Sensible Capacity, MBH Total Power Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW MBH KW Air On Temperature of Air on Condenser Coil Evaporator 5 F 5 F Coil Total Power Sensible Capacity, MBH Total Power Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW MBH KW These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.5 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total.3 KW) and the compressor motors but not the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group

7 PERFORMANCE (7/, & / TON SUPPLY AIR) MODEL DEG090 (SIDE DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEG090 (BOTTOM DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEG (SIDE DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEG (BOTTOM DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEG (SIDE DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEG (BOTTOM DUCT APPLICATIONS) RPM 530.TGY ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW NOTES:. Blower performance includes a wet evaporator coil and " filters.. Blower performance includes the maximum number of heat exchangers. = Larger Horsepower Alternate Motor Required. 3. Refer to page for the resistance of the unit accessories. ESP = External Static Pressure available for the supply and return air duct sytem. All internal unit resistances have been deducted from the total static pressure of the blower. Unitary Products Group 7

8 530.TGY PERFORMANCE (7/, & / TON SUPPLY AIR) MODEL DEE090 (SIDE DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEE090 (BOTTOM DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEE (SIDE DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEE (BOTTOM DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MODEL DEE (SIDE DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW Unitary Products Group

9 PERFORMANCE (/ TON SUPPLY AIR continued) 530.TGY MODEL DEE (BOTTOM DUCT APPLICATIONS) RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW MOTOR AND DRIVE DATA MODELS RANGE (RPM) HP SERVICE FACTOR MOTOR* FRAME SIZE EFFICIENCY (%) ADJUSTABLE MOTOR PULLEY PITCH BORE DIA. (IN.) (IN.) FIXED PULLEY PITCH BORE DIA. (IN.) (IN.) PITCH LENGTH (IN.) BELTS DESIG NATION DEE090 /, 975 DEG /..3 A9 DEE, 3 DEG 090 DEE 3 DEG / A5 DEE BX /.9. DEG (Notched) * All motors are 7 RPM, have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. QTY. FIELD WIRING Unitary Products Group 9

10 530.TGY ELECTRICAL DATA (DEG) MODEL DEG 090 POWER SUPPLY 0/ / / COMPRESSOR (# and #) RLA EACH LRA EACH OUTDOOR FAN MOTOR, (# & #) FLA EACH SUPPLY AIR MOTOR, FLA TOTAL UNIT AMPACITY, AMPS MAX. FUSE SIZE, AMPS MIN. WIRE SIZE,3 AWG HP 3HP 5 HP HP 3HP 5 HP HP 3HP 5 HP NOTES:. Dual numbers shown as "./7.3" amps indicates compressor #/#, respectively.. Dual element, time delay type. Amps shown as "0/5" indicates rating for LO HP/HI HP, respectively. Maximum HACR breaker of the same AMP size is applicable. 3. Based on 75 C copper conductors /5 VOLTAGE POWER SUPPLY MIN. MAX. VOLTAGE 0/ LIMITATIONS* *Utilization Range A in accordance with ARI Standard. ELECTRICAL DATA (DEE) MODEL DEE 090 POWER SUPPLY 0/ / / COMPRESSOR (# and #) RLA EACH LRA EACH OUTDOOR FAN MOTOR, (# & #) FLA EACH SUPPLY AIR MOTOR, FLA TOTAL UNIT AMPACITY, AMPS MAX. FUSE SIZE, AMPS MIN. WIRE SIZE,3 AWG /HP HP 3HP 5 HP / HP HP 3HP 5 HP /HP HP 3HP 5 HP NOTES:. Dual numbers shown as "./7.3" amps indicates compressor #/#, respectively.. Dual element, time delay type. Amps shown as "0/5" indicates rating for LO HP/HI HP, respectively. Maximum HACR breaker of the same AMP size is applicable. 3. Based on 75 C copper conductors /5 VOLTAGE POWER SUPPLY MIN. MAX. VOLTAGE 0/ LIMITATIONS* *Utilization Range A in accordance with ARI Standard. Unitary Products Group

11 530.TGY ACCESSORY STATIC RESISTANCES* EXTERNAL STATIC PRESSURE DROP RESISTANCE, IWG MODELS DESCRIPTION DEE DEG Economizer/Motorized Damper KW** KW DEE Electric Heaters KW KW KW*** *Deduct these resistance values from the available unit external static pressure shown in the respective Blower Performance Table. **9 KW Heater is only available on 7/ and / Ton Units. ***5 KW Heater is only available on and / Ton Units. COMPONENT WEIGHTS Basic Unit Options and Accessories NOTE: Weights are given in pounds. COMPONENT MODELS DEE & DEG 7/ TON TON / TON DEE (Cooling only) Mbh 0 DEG (Gas / Electric) 5 Mbh Mbh Economizer Motorized Outdoor Air Damper Oversized Motor 5 9 KW 9 Electric Heat KW (Nominal KW) KW (DEE only) 3 KW KW Roof Mounting Curb Unitary Products Group

12 530.TGY ELECTRICAL DATA Cooling / Electric Heating (DEE090, & ) UNIT SIZE, DEE 090 7/ TON UNIT with / OR HP TON UNIT with OR 3 HP TON UNIT with 3 OR 5 HP POWER SUPPLY SUPPLY AIR FLA MOTOR HP ACCESSORY ELECTRIC HEATERS TOTAL UNIT AMPACITY, AMPS MOTOR HP MAXIMUM FUSE SIZE,, AMPS MINIMUM WIRE SIZE,3 AWG MOTOR HP LO HI MODEL NO. KW STAGES TOTAL AMPS LO HI LO HI LO HI HE HE HE HE HE0595 HE055 HE055 HE05 HE059* HE05* HE05 HE053 HE0595 HE055 HE055 HE05 HE055 HE055 HE05 HH0555 HE055 HE055 HE05 HH0555 HE05* HE05 HE053 HE055 HE055 HE055 HE05 HE0555 HE055 HE055 HE05 HH0555 HE055 HE055 HE05 HH0555 HE05* HE05 HE053 HE055 HE055 HE055 HE05 HE Dual element, time delay type. Maximum HACR breaker of the same AMP size is applicable, except 575 voltages. Standard circuit breakers may be used in Canada and on applications over 0 amps where the heaters are separately fused. 3 Based on 75 C copper conductors. *These electric heaters do NOT include fuses. If fuses are required to meet a local code (eg. Chicago), an accessory fuse box with fuses (FB003) is available for field installation ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE KW CAP. MULTIPLIER Unitary Products Group

13 530.TGY UNIT DIMENSIONS (DEG/DEE 7/, & / TON) 337/ (090) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. DEG model shown UTILITIES ENTRY DATA HOLE OPENING SIZE (DIA.) USED FOR A 3/" KO Control Side 7/" KO Wiring Bottom B " KO Power Wiring (Side or Bottom) C " KO Gas Piping (Front) D /" Hole Gas Piping (Bottom), Openings in the bottom of the unit can be located by the slice in the insulation. 3/" Gas Piping MPT Required RETURN AIR SUPPLY AIR CONDENSER AIR OUTDOOR AIR (Economizer) CLEARANCES Front " " (Less Economizer) Back 3" (With Economizer) " (Less Economizer) Left Side (Filter Access) 5" (With Economizer) Right Side (Cond. Coil) " Below Unit 0" 7" With 3" Maximum Horizontal Above Unit Overhang (For Condenser Air Discharge) Units may be installed on combustible floors made from wood or class A, B or C roof covering material. Units must be installed oudoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. NOTE: A " clearance must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Locate unit so that the vent air outlet hood is at least: Three (3) feet above any forced air inlet located within horizontal feet (excluding those integral to the unit). Four () feet below, horizontal feet from, or foot above any door or gravity air inlet into the building. Four () feet from electric meters, gas meters, regulators and relief equipment. DUCT COVERS Units are shipped with all air duct openings covered. For side duct applications;.remove and discard the supply and return air duct covers..connect ductwork to duct flanges on the rear of the unit. For bottom duct applications;. Remove the side supply and return air duct covers to gain access to the bottom supply and return air duct covers.. Remove and discard the bottom duct covers. 3. Replace the side duct covers. DETAIL X SIDE SUPPLY AND RETURN AIR DUCT OPENINGS Unitary Products Group 3

14 530.TGY UNIT DIMENSIONS CONT D. (DEG/DEE 7/, & / TON) DETAIL Y UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS DIM. UNIT 7/ TON TON / TON A 33/" 3/" 3/" B 7/" 3/" 5" TYPICAL ROOFTOP INSTALLATION CENTER OF GRAVITY NOTE: Power wiring, control wiring, and gas piping points of entry into the cabinet (side or bottom) must be sealed to prevent rain water entry ino the building. Unitary Products Group

15 ROOF CURB DIMENSIONS (DEG/DEE 7/, & / TON) 530.TGY *Supply and Return Air (including duct support rails) as shown, are typical for bottom duct applications. For location of horizontal duct applications (on back of unit), refer to Unit Dimension details. ROOF CURB BENEFITS UNIT AND CURB APPLICATION Field Installed ➀ The " space between the ducts allows for jumping an existing roof joist. ➁ The " overall dimension of the ducts allows ductwork penetration between roof joists that are spaced on " centers. NOTE: Ducts can be installed onto the curb from the roof. All electrical and gas line connections can be made inside the curb. TYPICAL APPLICATIONS Roof penetration cut out for supply and return duct only to minimize noise transmission into building. Unitary Products Group 5

16 FACTORY INSTALLED OPTIONS ECONOMIZERS: Units equipped with the factoryinstalled economizer option have dampers that are positioned by a spring return, fully modulating damper actuator capable of introducing up to 0% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is determined by a single input electronic enthalpy control or by a dual input electronic enthalpy control. Simultaneous compressor and economizer operation is also possible. Economizer dampers are % low leakage type. A barometric relief damper is shipped in the return air compartment for field installation. The single enthalpy system contains a sensor that monitors the outdoor air which automatically operates the damper actuator allowing the dampers to open or close. The dual enthalpy system contains a second sensor that monitors the return air in addition to monitoring the outdoor air described above for a single enthalpy system. The logic module compares these two values and modulates the dampers providing the maximum efficiency of the economizer system. The economizer is completely wired and installed at the factory. Only the outdoor air hood, including its filters, need be assembled and installed in the field. ALTERNATE INDOOR FAN MOTORS: Larger horsepower motors are available on and / ton models to handle higher static pressure applications. PHENOLIC COATED CONDENSER COIL Special coating process that utilizes "Technicoat " processes. Coating is applied by total immersion of the complete coil for maximum protection. FIELDINSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER Includes a slidein / plugin damper assembly with fully modulating spring return motor actuator capable of introducing up to 0% outdoor air, one outdoor air electronic enthalpy sensor and a rainhood with filters. The rainhood is painted to match the basic unit and must be fieldassembled before installation. Economizer dampers are % low leakage type. The fixed outdoor air damper (shipped as standard equipment with every unit) can be used for barometric relief on units with an economizer. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER Includes the same damper system and rainhood with filters as described for a single enthalpy economizer above except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. The fixed outdoor air damper (shipped as standard equipment with every unit) can be used for barometric relief on units with an economizer. MOTORIZED AIR DAMPER Includes slidein / plugin damper assembly with position springreturn motor actuator and a rainhood with permanenttype filters. The outdoor air dampers open when the indoor fan motor is energized. The rainhood is shipped knocked down and must be field assembled. ELECTRIC HEATERS Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities of 9,,, 3 and 5 KW heating are available. FUSE BLOCK KIT This kit contains a fuse block including the fuses and is available for the 9 and KW 0volt heater kits. This kit satisfies the Chicago code requirements. ROOF CURB This " high full perimeter roof curb is shipped knocked down for field assembly. Its duct supports and insulated condensing section deck can be reversed to connect the ductwork on the opposite end. LOW AMBIENT KIT Head pressure controllers maintain stable operation by reducing the speed of the condenser fan motors when the outdoor temperature is between 5 and 0 F. Condenser fan motors with ball bearings and heavier windings are available for these low ambient applications. ANTIRECYCLE TIMER A timer to prevent unit compressors from short cycling. It assures a 5minute "offtime" between compressor cycles. PROPANE CONVERSION KIT Converts a gasfired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a gas valve. GAS PIPING This kit contains 3/" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shutoff. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) Provides orifices for proper furnace operation at altitudes up to,000 ft. For propane applications, the propane conversion kit will also be required. WALL THERMOSTAT The units are designed to operate with volt electronic and electromechanical thermostats. All units operate with two stage heat / two stage cool thermostats (with or without an economizer). 7/ & TON / TON Unitary Products Group P.O. Box 59, York, Pennsylvania USA 559 Subject to change without notice. Printed in U.S.A Copyright by York International Corporation 995. All Rights Reserved.. Codes: EBY,EGY 530.TGY Supersedes: 530.TGY (9)

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES 530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000

More information

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 (WORLD 50 HZ) 530.26-TG1YI (298) SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D3CE 036, 048, 060 & 076 D5CG 036, 048, 060 & 076 3, 4, 5 AND 6 NOMINAL TONS SHOWN SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION YORK Sunline 2000

More information

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204 TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS D1EG/D1EE036, 048, & 060 3, 4, AND 5 NOMINAL TONS 11-11.5 SEER FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. GENERAL YORK Model DEE/DEG units are

More information

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION. D1EG/D1EE 180 & and 20 NOMINAL TONS 9.5 EER

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION. D1EG/D1EE 180 & and 20 NOMINAL TONS 9.5 EER SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS D1EG/D1EE 180 & 40 15 and 0 NOMINAL TONS 9.5 EER SUNLINE PLUS DESCRIPTION YORK Sunline PLUS II units are convertible single package high efficiency rooftops.

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER

DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER (3 DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE CONDITIONERS DBUC/DBHB300 25 NOMINAL TONS 8.5 EER DUC and DHB convertible package rooftop models have two independent refrigerant circuits

More information

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION 530.18-TG4Y (600 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D2CE / D2CG 300 CONSTANT VOLUME 25 NOMINAL TONS 8.5 EER DCG Unit Shown DESCRIPTION Sunline 2000 series convertible

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS (500) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBHB/DBUC 180 & 40 15 AND 0 NOMINAL TONS 8.5-8.7 EER DESCRIPTION These units are convertible single package units. All models

More information

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS TECHNICAL GUIDE SUNLINE 2000 TM SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS MODELS B2CH 180 & B1CH 240 15 & 20 NOMINAL TONS 9.9-8.8 EER DESCRIPTION York Sunline 2000 Heat Pumps are convertible single package

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D1HG/D1HE 180 & D-0602

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D1HG/D1HE 180 & D-0602 TECHNICAL GUIDE DESCRIPTION YORK Sunline PLUS II units are convertible single package high efficiency rooftops. All models have independent dual refrigerant circuits for efficient part load operation.

More information

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common

More information

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SUNLINE ULTRA SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS 4 AND 5 NOMINAL TON GENERAL FEATURING

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SUNLINE ULTRA SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS 4 AND 5 NOMINAL TON GENERAL FEATURING TECHNICAL GUIDE SUNLINE ULTRA SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS 4 AND 5 NOMINAL TON D1HE/D1HG048 and 060 12 THROUGH 13.2 SEER DHG MODEL SHOWN FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL YORK s Sunline

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS PRELIMINARY DATA

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS PRELIMINARY DATA 036-21022-001 (200) TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS DL/DU-06, -07, -08, -10, -12 6-1/2, 7-1/2, 8-1/2, 10, 12-1/2 NOMINAL TONS 9.0-11.5

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

SINGLE PACKAGE COOLING UNITS

SINGLE PACKAGE COOLING UNITS 0365300B004 DESCRIPTION SINGLE PACKAGE COOLING UNITS DAPH08 THRU 060 / THRU 5 NOMINAL TONS AND 3 SEER These packaged cooling air conditioners are designed for outdoor installation. Only utility and duct

More information

TECHNICAL GUIDE DESCRIPTION SERIES 20 SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS J15, 18, 20 & 25 DH JTG-A-1007

TECHNICAL GUIDE DESCRIPTION SERIES 20 SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS J15, 18, 20 & 25 DH JTG-A-1007 TECHNICAL GUIDE SERIES 20 SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS J15, 18, 20 & 25 DH 15, 17.5, 20 & 25 NOMINAL TONS 10.8 EER (15 TONS), 10.2 EER (17.5 TONS), 9.7 EER (20

More information

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

TECHNICAL GUIDE (R-407C)

TECHNICAL GUIDE (R-407C) DESCRIPTION Sunline 2000 series convertible package rooftop models have two independent refrigerant circuits for efficient part load operation. Although the units are primarily designed for curb mounting

More information

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP The new Goodman CPH Commercial Packaged Heat Pump features the environmentally friendly refrigerant R-410A, which is chlorine-free to help

More information

TECHNICAL GUIDE (R-407C)

TECHNICAL GUIDE (R-407C) DESCRIPTION Sunline 2000 TM units are highly efficient, convertible rooftops. All models have dual refrigerant circuits for efficient part load operation. Although the units are primarily designed for

More information

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108 DESCRIPTION ACP packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. SINGLE PACKAGE GAS/ELECTRIC

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS 11.5 EER / 80% SSE THREE-PHASE COOLING CAPACITY: 118,000 BTU/H HEATING CAPACITY: 210,000 BTU/H CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS The new Goodman CPG Commercial Packaged Gas/

More information

DESCRIPTION TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING YTG-B-0807

DESCRIPTION TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING YTG-B-0807 DESCRIPTION TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON DNP024, 030, 036, 042, 048 AND 060 13 SEER York Affinity Series packaged cooling/heating

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

TECHNICAL GUIDE DESCRIPTION ACCLIMATE SERIES SINGLE PACKAGE COOLING UNITS DAPM024 THRU THRU 5 TON (13 SEER) STANDARD FEATURES / BENEFITS

TECHNICAL GUIDE DESCRIPTION ACCLIMATE SERIES SINGLE PACKAGE COOLING UNITS DAPM024 THRU THRU 5 TON (13 SEER) STANDARD FEATURES / BENEFITS TECHNICAL GUIDE ACCLIMATE SERIES SINGLE PACKAGE COOLING UNITS DAPM024 THRU 060 2 THRU 5 TON (13 SEER) DESCRIPTION These Luxaire Acclimate Series packaged cooling air conditioners are designed for outdoor

More information

PGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner

PGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner PGB SERIES 0 SEER SelfContained Gas/Electric Packaged Air Conditioner 2 and 5 Ton Cooling Capacity: 2,600 to 58,000 BTUH Heating Input Rates: 6,000 to 0,000 BTUH The PGB outdoor package unit is a selfcontained

More information

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON DNH018 THROUGH 060 UP TO 12.4 SEER YORK s Champion

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DW-03, -04 & BTG-D-0109

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DW-03, -04 & BTG-D-0109 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DW-03, -04 & -05 3, 4 & 5 NOMINAL TONS 13.00 to 13.50 SEER DESCRIPTION UP units are convertible single package air

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DY 036, 048 & YTG-E-0109

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DY 036, 048 & YTG-E-0109 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DY 036, 048 & 060 3, 4 & 5 NOMINAL TONS 14.00 SEER DESCRIPTION YORK Sunline Magnum units are convertible single package

More information

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC GPG COMMERCIAL 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS The Goodman GPG Commercial Packaged Gas/ Electric 10 & 13 SEER units feature energy-efficient cooling and

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 036, 048 & YTG-C-0308

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 036, 048 & YTG-C-0308 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 036, 048 & 060 3, 4 & 5 NOMINAL TONS 12.2 THROUGH 13.2 SEER DESCRIPTION YORK Sunline Ultra units are convertible

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON GENERAL FEATURING

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON GENERAL FEATURING TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON D1YH018 THROUGH UP TO 12.4 SEER FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL The DYH package units are designed

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

TECHNICAL GUIDE 50 HZ

TECHNICAL GUIDE 50 HZ TECHNICAL GUIDE 50 HZ HIGH EFFICIENCY SINGLE PACKAGE HEAT PUMPS BP 090 & 120 7-1/2 and 10 NOMINAL TONS 9.1 EER DESCRIPTION YORK Predator heat pump units are convertible single packages with a common footprint

More information

DESCRIPTION SINGLE PACKAGE CONVERTIBLE SERIES HEAT PUMPS FEATURES

DESCRIPTION SINGLE PACKAGE CONVERTIBLE SERIES HEAT PUMPS FEATURES (00 DESCRIPTION SINGLE PACKAGE CONVERTIBLE SERIES HEAT PUMPS BCCB036, 048 & 0 (8/, 4V) BECB036, 048 & 0 (575V) 3, 4 AND 5 NOMI NAL TONS (0 SEER) The series heat pumps are convertible single package units

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems

More information

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized

More information

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained

More information

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DK-03, -04, -05 and -A6 3, 4, 5 and 6 NOMINAL TONS 13.0 SEER 10.4 EER DESCRIPTION MagnaDRY units are convertible single

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS. BP 036 thru 072 HIGH EFFICIENCY YTG-D-0109

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS. BP 036 thru 072 HIGH EFFICIENCY YTG-D-0109 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BP 036 thru 072 3-6 NOMINAL TONS HIGH EFFICIENCY DESCRIPTION YORK Sunline 2000 heat pumps are convertible single package units with a common cabinet and a

More information

RGMA Series Package Gas Electric SPECIFICATIONS

RGMA Series Package Gas Electric SPECIFICATIONS RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

TECHNICAL GUIDE 50Hz DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS

TECHNICAL GUIDE 50Hz DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS TECHNICAL GUIDE 50Hz SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS DM090, 120, 150 7-1/2, 10, 12-1/2 NOMINAL TONS 9.0-10.0 EER DESCRIPTION YORK Predator units are convertible single

More information

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 180, 210, 240 & YTG-F-1009

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 180, 210, 240 & YTG-F-1009 TECHNICAL GUIDE DESCRIPTION YORK Sunline Ultra units are convertible single package high efficiency rooftops. All models have independent dual refrigerant circuits for efficient part load operation. Although

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DL-15, -20 & BTG-F-1109

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DL-15, -20 & BTG-F-1109 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DL-15, -20 & -25 15, 20 & 25 NOMINAL TONS DESCRIPTION UP DL units are convertible single package high efficiency rooftops.

More information

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON 14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DR 036, 048, 060 and 072 3, 4, 5 and 6 NOMINAL TONS 13.0 SEER 10.4 EER YORK Sunline MagnaDRY units are

More information

SINGLE PACKAGE GAS/ELECTRIC AIR-COOLED AIR CONDITIONERS

SINGLE PACKAGE GAS/ELECTRIC AIR-COOLED AIR CONDITIONERS 530.46TG4L (500) DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIRCOOLED AIR CONDITIONERS DAYA018 THRU 048 AND DBYA060 11/2 THRU 5 NOMINAL TONS 10 SEER / 80% AFUE These packaged cooling/heating air conditioners

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) PAH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A CPC Series 15- & 20-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Air Conditioner with R-410A

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

13 SEER Light Commercial 3 Phase

13 SEER Light Commercial 3 Phase 13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity

More information

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01 PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top

More information

TECHNICAL GUIDE R-410A ACCLIMATE SERIES 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A ACCLIMATE SERIES 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A ACCLIMATE SERIES 2-5 TON 60 Hertz Description These Luxaire Acclimate packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

TECHNICAL GUIDE R-410A AFFINITY SERIES BHX, BHQ AND BHZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES BHX, BHQ AND BHZ MODELS 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A AFFINITY SERIES, AND MODELS 2-5 TON 60 Hertz Description These York Affinity packaged heat pumps are designed for outdoor installation. Only utility and duct connections are required

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

TECHNICAL GUIDE R-410A AFFINITY SERIES DNX, DNQ, DNZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DNX, DNQ, DNZ MODELS 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A AFFINITY SERIES DNX,, MODELS 2-5 TON 60 Hertz Description These York Affinity packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct

More information

Model 558D/559F Sizes

Model 558D/559F Sizes Bryant Air Conditioning COMMERCIAL SINGLE-PACKAGE ROOFTOP ELECTRIC COOLING UNITS Model 558D/559F Sizes 036-300 3to25Tons Model 558D036-072 Model 559F180,216 Model 558D090-150 Model 559F240,300 DESCRIPTION

More information