LOAD CELL USER MANUAL RRI-T-ATEX

Size: px
Start display at page:

Download "LOAD CELL USER MANUAL RRI-T-ATEX"

Transcription

1 ATEX / IECEx WIRELESS LOAD CELL USER MANUAL RRI-T-ATEX

2

3 FRONT COVER CONTENTS INTRODUCTION SECTION : SECTION : SECTION 3: SECTION 4: SECTION 5: SECTION 6: SECTION 7: SECTION 8: SECTION 9: SECTION 0: SECTION : SECTION : SAFETY INSTRUCTIONS INSTRUCTIONS SPECIFIC TO HAZARDOUS AREA INSTALLATIONS OPERATING INSTRUCTIONS HANDSET INSTRUCTIONS EQUIPMENT DATA SHEET ERROR MESSAGES CERTIFICATION INSPECTION AND MAINTENANCE INSTRUCTIONS CALIBRATION REPAIRS WEEE REGULATIONS WARRANTY 3

4 INTRODUCTION The Red Rooster ATEX / IECEx wireless load cell is approved for use in Zones & for Gas and also Zones & for dust. ATEX coding - IECEx coding - Ex II GD Ex ib IIC T4 Gb Ex ib IIIC T35 C Db This intrinsically safe wireless load cell is part of the RRI-T range of wireless load cells developed over many years by Red Rooster to meet the increasing requirements of our customers. Ideal for use in the offshore industry, engineering and chemical industries and wherever accurate measurements are required in a hazardous area. The load cells range from 5 tonne to 500 tonne and are manufactured from high strength low weight Duralloy. All load cells are proof loaded to 50% of the rated capacity with a minimum factor of safety of 5:. The load cell and the handset has IP67 protection against water and dust. The handset has an easily accessible battery compartment and the batteries on the link are accessed by remving a panel with 4 x M6 socket head cap screws. Load cells come complete with a robust carry case up to 50 tonne and a case for the handset over 50 tonne. The handset can be changed to indicate Tonne and LBS. 4

5 SAFETY INSTRUCTIONS.0 INSTRUCTIONS FOR THE SAFE USE OF LOAD CELLS Instructions for the safe use of RRI-T-ATEX Load Cells and Displays The information in this leaflet should be passed to the user of the equipment. The contents of this section are designed for the guidance of personnel using Load Links. LOAD CELL CHECKS WHEN IN USE Ensure the serial number, capacity, calibration date and the Ex rating are easily read and match the calibration report. Ensure that the load cell / rigging gear is of an equal or greater capacity that the load being applied. Ensure that the rigging gear fits correctly into the link. Ensure that the load runs through the centre of the link. Ensure that the operator will be able to read the load on the load cell display when needed. Ensure that the load cell works correctly before lifting the load. Read the manual before use. The load must be applied in a linear manner. Do not apply a shock or twisting load to the load link. Do not leave in the sun. Cover from direct sunlight when not in use. Do not drop or apply a mechanical blow to the load link or display unit. Do not immerse either the load link or display unit in any fluids. Avoid use for 5-0 minutes after moving between areas of different temperatures. The device is sealed to IP67 standard The use of chemicals on the load cell should be avoided. Be aware of external influences on the load cell such as ambient temperature, wind, rain, chemicals and coming in contact with moving objects. SAFE OPERATION Test run the equipment prior to application of a load and ensure that the equipment, including its control and safety devices are functioning correctly. Ensure that only authorised personnel operate this equipment. Do not exceed the stated safe working load / capacity. Ensure that the load is securely supported by certified lifting gear (slings and shackles) with an equal or higher safe working load in the configuration used and that the load to be lifted cannot escape. Stand clear of the load when lifting or lowering, and ensure that the point which you are standing is safe and secure and within range of the load cell output. Ensure that other personnel cannot enter the immediate area where the lift is taking place. Never leave a suspended load unattended. If it is not possible to site yourself in a position where you can see the load at all stages, appoint a banksman to cover the area which you cannot see and establish a reliable method of communication (verbal or hand signals) before starting the lift. If you suspect that the equipment is defective or is developing a fault, stop the lifting operation immediately. Make the area safe by returning the load to a rest position, but if this is not possible the area should be cordoned off, and the advice of you Superior or Safety Officer sought. Do not use if damaged or if you know the load cell has been overloaded. Batteries must be correctly fitted and the battery compartment cover must be securely closed. ONLY CHANGE BATTERIES IN A SAFE AREA 5

6 Instructions specific to hazardous area installations (in accordance with EN/IEC :0 clause 30) The following instructions relevant to safe use in a hazardous area apply to equipment covered by certificate numbers IECEx SIR X and Sira 7ATEX37X.. The certification marking is as follows: The Durablack label is manufactured from anodised aluminium with a Durablack coating. The label is self-adhesive.. The equipment may be used in zones & with flammable gases and vapours with apparatus groups IIA, IIB & IIC and with temperature classes T, T, T3, andt4. 3. The equipment may be used in zones & with flammable dusts, fibres and flyings in groups IIIA, IIIB and IIIC, with a layer auto-ignition temperature of not less than 75 K above the maximum surface temperature marked in the dust coding. 4. The equipment is only certified for use in ambient temperatures in the range -0ºC to +40ºC and should not be used outside this range 5. Installation shall be carried out in accordance with the applicable code of practice by suitably-trained personnel 6. There are no special checking or maintenance conditions other than a periodic check. 7. With regard to explosion safety, it is not necessary to check for correct operation. 8. The equipment contains no user-replaceable parts and is not intended to be repaired by the user. Repair of the equipment is to be carried out by the manufacturer, or their approved agents, in accordance with the applicable code of practice. 9. Repair of this equipment shall be carried out in accordance with the applicable code of practice 0. If the equipment is likely to come into contact with aggressive substances, e.g. acidic liquids or gases that may attack metals or solvents that may affect polymeric materials, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected thus ensuring that the type of protection is not compromised. 6

7 . The certificate number has an X suffix which indicates that special conditions of installation and use apply. Those installing or inspecting this equipment must have access to the contents of the certificate or these instructions. The conditions listed in the certificate are reproduced below: i) Use only the Energizer Ultimate AA size, primary lithium cells, Type L9, component certified under certificate no Baseefa 4ATEX007U. Additional information A. A copy of the certificates listed above are available. B. See manual for operating and maintenance instructions. C. Where applicable, the address of the importer or repairer should be specified. D. On being put into service, the equipment must be accompanied by a translation of the instructions in the language or languages of the country in which the equipment is to be used and by the instructions in the original language. 7

8 OPERATING INSTRUCTIONS 3.0 SPECIFICATION Display enclosure: Splash Proof (IP67) Operating time: 54hrs depending on battery condition and charge Operating Range: Up to 500 Metres (depending on local conditions) SWITCH ON LOAD CELL: Press the push button on the front of the cell. The push button should be in the inward position when switched on. POWER ON / OFF THE DISPLAY: Press the power key to turn the display on. A long press will power the handheld on and off. Hold the power key until the display shows BUSY then release the key. A quick press will toggle the backlight on and off when in manual backlight mode NEXT KEY: If the display has been setup to read more than one load cell this button can be used to switch between the cells. A short press will step to the next transmitter, before the load is shown a prompt will appear which can either be the load cell serial number or a User defined name. A long press of the next key will show the serial number or User defined name of the load cell currently connected to the display. TO TARE THE DISPLAY: Tare key. A short press will toggle between gross and zeroed net mode. i.e. If the display shows gross then pressing the key will zero the display. Pressing the key when in net mode will return the display to gross mode. The Gross and Nett modes are indicated as described below. Gross and Nett states are retained through power off. Long Press - When in net mode will briefly display the Gross value but remain in net mode. G - The display is showing Gross weight. NET - The display is showing Net weight STANDBY MODE: To put the link in to stand-by mode (without switching the load cell off) press and hold the POWER key on the display, the display will show BUSY it will take a few seconds for the load cell to switch into standby mode, once this has happened the display will switch itself off. To start using the equipment again press the POWER key, the display will show BUSY It may take a few seconds until the display picks up the signal and starts normal weighing. BATTERIES: The load cell and Display are both powered by AA Batteries. You must use ENERGIZER AA LITHIUM L9 type. The display and load cell both use batteries each. FITTING BATTERIES: On the load cell 4 x M6 cap screws need to be removed before removing the battery cover. The battery compartment cover on the handset is accessed by removing x philips head screws ALL BATTERIES MUST BE CHANGED IN A SAFE AREA. 8

9 HANDSET INSTRUCTIONS NO. DESCRIPTION TARE NEXT 3 ON / OFF 4 GROSS WEIGHT 5 NETT WEIGHT 6 SIGNAL LOW 7 HANDSET BATTERY LOW 8 LOAD CELL BATTERY LOW 9

10 RRI-T-ATEX 5 TONNE - 50 TONNE ATEX / IECEx WIRELESS LOAD CELL USER MANUAL GAS ZONES + DUST ZONES + II GD MODEL A B C D E F RRI T5 ATX Ø7,5 RRI T,5 ATX Ø45 RRI T5 ATX Ø55 RRI T50 ATX Ø75 Ex ib IIC T4 Gb Ex ib IIIC T35oC Db 5 7 B F E D 3 e manufacture 3 07 STANDARD FEATURES Tare Zero & peak hold High resolution 5 Tonne to 500 Tonne Range 500m Lightweight high strength aluminium alloy Frequency.4 GHz Robust carry case Long battery life with battery level indicator Turn off on load cell or remotely from handset Note: Replaceable batteries in display and cell High factor of safety smit board item 3 there is hickness for item mm for the spacers item 4 PARTS LIST ITEM QTY Model PART NUMBER A B C DESCRIPTION D E FØ DRG Front Panel (for RRI T) 3 RRI-T5-ATEX DRG DRG Rear Panel 3 (for RRI AA) 74 Battery Cover x NBR 70 RRI-T.5-ATEX NBR7D O ring 50 O ring ISO x 0 Hexagon socket head shoulder screws (M5x6) 7 RRI-T5-ATEX ISO x Hexagon socket head 60 shoulder screws 74 (M5x) 8 4 RS Threaded Insert M RRI-T50-ATEX ISO 009 M3 x 0 IPR SAD Countersunk 75 Screw On/Off Switch DRG 49 0 (5T) or DRG (,5T) or Body DRG (5T) or DRG (50T) X4 SAe Technical Specification Battery Holder Mantracourt Transmit Board aaa M Model plastic bolt RRI-T5-ATEX RRI-T.5-ATEX M3x8 Spacer RRI-T5-ATEX RRI-T50-ATEX 6 DRG 49 0 Product Label Scale Material Capacity Title of 5 Part tonne.5 tonne 5 tonne Part Number 50 tonne RRI T5 ATX, RRI T,5 ATX, : Resolution kg RRI T5 ATX, kg RRI T50 ATX kg DRG kg (ATEX) Surname Date Signature / Designed By T. Mikolajewski Accuracy < +/- 0.5% Date 07//0 of FSD* unless otherwise specified Drawn By T. Mikolajewski Temp Range -0 C to +40 C 4/07/07 all dimensions are in milimeters 4/07/07 Tolerances Revision Weight Linear Checked By B. Aitken IP Rating IP67 up to 5 0,05 3 N/A over 5 up to 30 0, over 30 up to 0 0, over 0 up to 500 0,5 over 500 up to 000 0,5 over 000 Approved By Sheet Size A4 Note: A layer of silicone grease may be applied to the jointing surfaces where O rings are fitted 3 Handset Dimensions 5mm x 90mm Replaces x 34mm Drawing B. Aitken (70g) Handset Title of Project Display 8 digit x 9mm Angular 0,5 Profile Number Surface Roughness Handset Wireless Battery Load Cell ATEX / IECEx Use Only Certification x Energizer L9 "AA" BatteriesIf In Doubt Ask Wireless Load Cell Battery Life 6 Only baseefa certified AA cells can be used C A Use Only x Energizer L9 AA Batteries Lithium "AA" x 5 min sessions per day: Months Continuous use: 54 Hours Shackle Size 6.5 tonne 3.5 tonne 5 tonne 55 tonne Cell Weight.5 kg 4.5 kg 6.5 kg 3.0 kg Cell with Case 6.5 kg 8.5 kg 0.5 kg 9.0 kg F N0 Image for illustration purposes only *Based on a BS60 Grade Calibration Machine Only replace batteries in a safe area Information subject to change without notice 0 RED ROOSTER LIFTING T: +44 (0) Nauta House, The Meadows E: sales@redroosterlifting.com Oldmeldrum, Aberdeenshire W: United Kingdom, AB5 0EZ C06-LC6 REV0

11 RRI-T-ATEX 00 TONNE - 00 TONNE ATEX / IECEx WIRELESS LOAD CELL USER MANUAL GAS ZONES + DUST ZONES + II GD MODEL A B C D E F RRI T00 ATX Ø00 RRI T50 ATX Ø0 RRI T00 ATX Ø45 Ex ib IIC T4 Gb RRI T300 ATX Ø80 RRI T400 ATX Ex ib IIIC T35oC Db Ø90 RRI T500 ATX Ø0 B F REVISION HISTORY REV. DATE APPROVED 0 D E STANDARD FEATURES Tare Zero & peak hold High resolution 5 Tonne to 500 Tonne Range 500m Lightweight high strength aluminium alloy 5 Frequency.4 GHz Note: Robust carry case Long battery life with battery level indicator 9 Only baseefa certified AA cells can be used Turn off on load cell or remotely from handset 6 7 Replaceable batteries in display and cell High factor of safety 4 C A F 3 Note: A layer of silicone grease may be applied to the jointing surfaces where O rings are fitted the manufacture Material Type: Alloy EN AW 7075 T65 Total of Magnesium, Titanium and Zirconium is less than 7,5% Model DRG RRI-T00-ATEX (300T) or DRG 5 0 (400T) RRI-T50-ATEX or DRG (500T) RRI-T00-ATEX Capacity 6 DRG Front Panel (for RRI T) 00 tonne 50 tonne 00 tonne Scale Material Title of Part Part Number Resolution Not to RRI T00 ATX, RRI T50 ATX, RRI T00 ATX, Scale kg RRI T300 ATX, kg RRI T400 ATX, RRI T500 ATX kg DRG (ATEX Surname Date Signature / Designed By T. Mikolajewski Date //07 unless otherwise specified Accuracy < +/- 0.5% of FSD* //07 Temp Range ansmit board item 0 there is IP Rating ll thickness for item 6 and 6 mm for the spacers Handset item Dimensions A3 Handset Display Handset Battery Wireless Load Cell Battery Life PARTS LIST ITEM QTY PART NUMBER DRG x NBR x 3 NBR ISO x ISO x 6 4 RS ISO 009 M3 x 8 8 IPR SAD X4 SAe aaa M plastic bolt 3 Technical DRG Specification DRG (00T) or DRG (50T) or DRG 50 0 (00T) or Model A B C D E FØ RRI-T00-ATEX RRI-T50-ATEX RRI-T00-ATEX Drawn By Checked By Approved By Sheet Size T. Mikolajewski //07 B. Aitken Title of Project DRG C to +40 C IP67 Wireless Load 5mm Cell ATEX x 90mm / IECEx x 34mm Certification (70g) 8 digit x 9mm Use Only x Energizer L9 "AA" Batteries Use Only x Energizer L9 AA Batteries Lithium "AA" x 5 min sessions per day: Months Continuous use: 54 Hours Shackle Size 0 tonne 50 tonne 00 tonne Cell Weight 50 kg 75 kg 95 kg DESCRIPTION Battery Cover O ring O ring Hexagon socket head shoulder screws (M5x6 Hexagon socket head shoulder screws (M5x Threaded Insert M5 Countersunk Screw On/Off Switch Battery Holder Mantracourt Transmit Board M3x8 Spacer Revision Weight 0 N/A Replaces Drawing Profile Number Product Label Body Rear Panel (for RRI AA) all dimensions are in milimete Tolerances Linear up to 5 0,05 over 5 up to 30 0, over 30 up to 0 0, over 0 up to 500 0,5 over 500 up to 000 0,5 over 000 Angular 0,5 N0 Surface Roughness If In Doubt Ask Image for illustration purposes only *Based on a BS60 Grade Calibration Machine Only replace batteries in a safe area Information subject to change without notice RED ROOSTER LIFTING T: +44 (0) Nauta House, The Meadows E: sales@redroosterlifting.com Oldmeldrum, Aberdeenshire W: United Kingdom, AB5 0EZ C06-LC7 REV0

12 RRI-T-ATEX 300 TONNE TONNE ATEX / IECEx WIRELESS LOAD CELL USER MANUAL GAS ZONES + DUST ZONES + II GD MODEL A B C D E F RRI T00 ATX Ø00 RRI T50 ATX Ø0 RRI T00 ATX Ø45 Ex ib IIC T4 Gb Ex ib IIIC T35oC Db RRI T300 ATX Ø80 RRI T400 ATX Ø90 RRI T500 ATX Ø0 B F REVISION HISTORY REV. DATE APPROVED 0 D E STANDARD FEATURES Tare Zero & peak 4 hold 3 5 High resolution 5 Tonne to 500 Tonne Range 500m Lightweight high strength aluminium alloy 5 Frequency.4 GHz Note: Robust carry case Long battery life with battery level indicator 9 Only baseefa certified AA cells can be used Turn off on load cell 6 or remotely 7 from handset Replaceable batteries in display and cell High factor of safety 4 C A F 3 Note: A layer of silicone grease may be applied to the jointing surfaces where O rings are fitted the manufacture Material Type: Alloy EN AW 7075 T65 Total of Magnesium, Titanium and Zirconium is less than 7,5% Model DRG RRI-T300-ATEX (300T) or DRG 5 0 (400T) RRI-T400-ATEX or DRG (500T) RRI-T500-ATEX Capacity 6 DRG Front Panel (for RRI T) 300 tonne 400 tonne 500 tonne Scale Material Title of Part Part Number Resolution Not to RRI T00 ATX, RRI T50 ATX, RRI T00 ATX, Scale kg RRI T300 ATX, kg RRI T400 ATX, RRI T500 ATX kg DRG (ATEX Surname Date Signature / Designed By T. Mikolajewski Date //07 unless otherwise specified Accuracy < +/- 0.5% of FSD* //07 Temp Range ansmit board item 0 there is IP Rating ll thickness for item 6 and 6 mm for the spacers Handset item Dimensions A3 Model A B C D E FØ ITEM QTY PART NUMBER DRG RRI-T300-ATEX x 050 NBR O ring x 3 NBR 70 O ring RRI-T400-ATEX ISO x ISO x 6 4 RS RRI-T500-ATEX Handset Display Handset Battery Wireless Load Cell Battery Life PARTS LIST -0 C to +40 C IP67 Wireless Load 5mm Cell ATEX x 90mm / IECEx x 34mm Certification (70g) 8 digit x 9mm Use Only x Energizer L9 "AA" Batteries Use Only x Energizer L9 AA Batteries Lithium "AA" x 5 min sessions per day: Months Continuous use: 54 Hours DESCRIPTION Battery Cover Hexagon socket head shoulder screws (M5x6 Hexagon socket head shoulder screws (M5x Threaded Insert M5 ISO 009 M3 x 8 Countersunk Screw IPR SAD On/Off Switch Battery Holder X4 SAe Mantracourt Transmit Board aaa M3x8 Spacer M plastic bolt Technical DRG Specification 49 0 Product Label DRG (00T) or DRG (50T) or DRG 50 0 (00T) or Body Drawn By Checked By Approved By Sheet Size T. Mikolajewski //07 B. Aitken Title of Project DRG Revision Weight 0 N/A Replaces Drawing Profile Number Rear Panel (for RRI AA) Shackle Size 300 tonne 400 tonne 500 tonne Cell Weight 60 kg 5 kg 35 kg all dimensions are in milimete Tolerances Linear up to 5 0,05 over 5 up to 30 0, over 30 up to 0 0, over 0 up to 500 0,5 over 500 up to 000 0,5 over 000 Angular 0,5 N0 Surface Roughness If In Doubt Ask Image for illustration purposes only *Based on a BS60 Grade Calibration Machine Only replace batteries in a safe area Information subject to change without notice RED ROOSTER LIFTING T: +44 (0) Nauta House, The Meadows E: sales@redroosterlifting.com Oldmeldrum, Aberdeenshire W: United Kingdom, AB5 0EZ C06-LC8 REV0

13 ERROR MESSAGES 6.0 SIG LOW: The radio signal form the transmitter module is low. The module is still functioning but the limit of range may be near. Communications may start to deteriorate when this warning is shown. Until the display shows the communications are still OK and the display can be relied on for accuracy. BATT LOW: The batteries in the handheld are low and will need to be replaced. REMOTE ERROR: The transmitter module has an error that the handset does not recognise. REMOTE BATT LOW: The batteries in the load cell are low and will need replaced. ERROR : The transmitter module has a strain gauge input and is in shunt calibration mode. An external module has placed the transmitter module in Shunt Calibration mode so rather than display a misleading reading this error is displayed instead. Modules such as the X4-SA support this error type. ERROR : Input integrity error. The transmitter module has found a problem with the input. There may be open or short circuits. Rather than display a misleading reading this error is displayed instead. Only certain transmitter modules support this error such as the X4-SA. OVERLOAD: The overload limit set by the user has been exceeded. IF THESE PROBLEMS STILL PERSIST, CALL RED ROOSTER IMEDIATELY NOTE:. Always test the equipment before assembling in to a lifting configuration.. Always switch the load cell and display ON before applying a load. 3. The load cell display cannot be tested without first being attached to its matching load cell. CERTIFICATION 7.0 Red Rooster ATEX load cells are supplied with an EU declaration of conformity, IECEx certificate of conformity, calibration certificate, data sheet and a user manual. The calibration certificate is valid for months. After this we recommend the load cell is returned to Red Rooster or an approved calibration company. Red Rooster ATEX wireless load cells come with a month waranty. See Red Rooster Lifting Ltd standard conditions of sale for more information. 3

14 INSPECTION AND MAINTENANCE INSTRUCTIONS 8.0 The Wireless Load Cell will only remain certified and approved if it is inspected and maintained in accordance with these instructions and the relevant standards. For intrinsically safe equipment this is covered in table of IEC INSPECTION GRADES: The standard identifies 3 different grades of inspections for the use of Ex equipment. Visual Close Detailed VISUAL An inspection before use which identifies, without the use of access tools those defects such as damage or missing parts which is apparent to the eye. A visual inspection does not require the de-energising of the equipment. CLOSE The inspection covers the visual inspection and in addition covers defects such as loose screws or covers only apparent with the use of access tools. (Probably done while changing batteries) Both the visual and the close inspection can be carried out by the user of the equipment after reading this manual. DETAILED The inspection covers the visual and close examination and in addition inspects all seals, electronic parts and conformity with the Ex certificate. This inspection does require the de-energising of the unit. For hand held equipment a Periodic inspection is required, which must be carried out at a maximum interval of Year. This must be done by the manufacturer of the product who has the requisite knowledge of the equipment and can confirm conformity to the Ex certification. (This can be carried out during the yearly calibration of the Wireless load Cell) REQUIRED DOCUMENTATION For the Close and Detailed inspection the documentation covering the unit should be available giving the Zone classification and the ATEX / IECEx equipment group, gas or dust groups and temperature class. Also any special installation conditions (X) CALIBRATION 9.0 Calibration must be carried out in accordance with BS EN ISO 7500-:004 and the procedure is to conform to BS EN ISO 376: 0. Calibration is accessed using a keypad routine and code (refer to manufacturer); if this is not done correctly it will corrupt the unit. For a fast and efficient calibration or if you are experiencing difficulties with the functions or operation of your load cell please contact Red Rooster on either or or us at sales@redroosterlifting.com REPAIRS 0.0 Repairs to Red Rooster ATEX / IECEx wireless load cells should only be carried out by the manufacturer or an agent approved by Red Rooster Lifting Ltd. All repairs must follow our procedures and codes of practice for ATEX / IECEx wireless load cells. 4

15 WASTE ELECTRICAL & ELECTRONIC EQUIPMENT REGULATIONS.0 The Waste Electrical and Electronic Equipment Regulations No 33 as amended by the Waste Electrical and Electronic Equipment (Amendment) Regulations 03 ( the WEEE Regulations ) implement the majority of the provisions of the European Parliament and Council Directive on Waste Electrical and Electronic Equipment ( the WEEE Directive ) and the subsequent European Parliament and Council Directive 3 that amended the WEEE Directive. All Electronic and Electrical Equipment (EEE) placed onto the market from January, 007 must be marked with this symbol to indicate that it is covered by the WEEE Directive, the provisions of which require that producers or manufacturers of EEE become liable to pay for take-back treatment and recycling of end of life equipment (WEEE): Red Rooster Lifting Ltd is committed to meeting the requirements of the European Union (EU) Waste Electrical and Electronic Equipment (WEEE) Directive. This Directive requires producers of electrical and electronic equipment to finance the recycling of their products placed on the EU market after August 3, 005. Red Rooster Lifting Ltd offers a product take back service to its business customers. This initiative is part of the companies Environmental Policy and as such Red Rooster Lifting Ltd have registered as a small EEE producer at our premises and SEPA for the repair and refurbishment of WEEE at our premises at Oldmeldrum under exempt activity Schedule 3 Paragraph 47 Therefore In compliance with the above regulations you may return this Load Cell to us when it has expired its natural usable life and as such is classed as Waste Electrical and Electronic Equipment. Our SEPA Producer Registration Number is WEE/CJ650ZQ WARRANTY.0 Every effort has been made to ensure that this quality product from the Red Rooster range reaches you in good condition. However in the event that any damage has arisen in transit please notify us immediately. In the unlikely event that any fault in materials or workmanship should arise within TWELVE MONTHS of purchase, please return the goods together with details of the fault to the Address below : Carriage Costs incurred (UK and Eire) will be reimbursed on warranty repairs or replacements RED ROOSTER LIFTING LIMITED NAUTA HOUSE THE MEADOWS OLDMELDRUM ABERDEENSHIRE AB5 0EZ T: E: Ref: Red Rooster Lifting general conditions of sale clauses 5 & 7 The above does not affect your statutory rights 5

16 Head Office: T: +44 (0) Nauta House Oldmeldrum E: The Meadows Aberdeenshire, AB5 0EZ W: Depot: Unit 6 Kelvin Way T: +44 (0) Kelvin Way Trading Estate West Bromwich, B70 7TW

LOAD CELL PRODUCTS CATALOGUE

LOAD CELL PRODUCTS CATALOGUE LOAD CELL PRODUCTS CATALOGUE 2 CONTENTS PAGE INTRODUCTION 4 SECTION 1 - LOAD CELLS 5 SELF INDICATING CELLS TYPE RRI-S 6 CABLED CELLS TYPE RRI-C 7 TELEMETRY CELLS TYPE RRI-T 8 SECTION 2 - ATEX / IECEx WIRELESS

More information

LOAD SHACKLE USER MANUAL RR-SC RR-ST

LOAD SHACKLE USER MANUAL RR-SC RR-ST LOAD SHACKLE USER MANUAL RR-SC RR-ST FRONT COVER CONTENTS INTRODUCTION SAFETY INSTRUCTIONS SECTION 1: REMOTE INDICATING LOAD SHACKLE CABLED - RR-SC 1.1 RR-SC SPECIFICATION 1.2 RR-SC OPERATION INSTRUCTIONS

More information

LOAD CELL USER MANUAL RRI-S RRI-C RRI-T

LOAD CELL USER MANUAL RRI-S RRI-C RRI-T LOAD CELL USER MANUAL RRI-S RRI-C RRI-T FRONT COVER CONTENTS INTRODUCTION SAFETY INSTRUCTIONS SECTION 1: SELF-INDICATING LOAD CELL - RRI-S 1.1 RRI-S SPECIFICATION 1.2 RRI-S OPERATION INSTRUCTIONS 1.3

More information

LOAD MEASURING EQUIPMENT DATA SHEETS

LOAD MEASURING EQUIPMENT DATA SHEETS LOAD MEASURING EQUIPMENT DATA SHEETS www.rriuk.com red rooster TENSILE LINK SELF INDICATING (Type: SWL) Manufactured in a range of capacities from 2 tonnes to 25 tonnes utilising high strength, low weight

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

Operating Instructions

Operating Instructions Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

DIAGNOSTIC TOOL BATTERY

DIAGNOSTIC TOOL BATTERY BATTERY DIAGNOSTIC TOOL 81164 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent

More information

Operator Instructions for Tension Links

Operator Instructions for Tension Links Operator Instructions for Tension Links Page 1 of 9 Table of Contents Introduction... 3 Markings CE... 3 Electromagnetic Compatibility (EMC)... 3 Tension Link Type/Model Number... 3 Supplier... 3 Service...

More information

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T** Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing

More information

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION II 2 G I M2 Ref. ID 2310, Rev. A Email: sales@cord-ex.com www.cordexinstruments.com CONTENTS 1. READ THIS FIRST 1. READ THIS FIRST 1 Liability 1 Trademark

More information

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013) Adam Equipment DUNE DCT SERIES (P.N. 9384, Revision B2, June 2013) Adam Equipment Company 2013 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION

More information

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4 1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Wolflite XT Rechargeable LED Handlamp

Wolflite XT Rechargeable LED Handlamp Wolflite XT Rechargeable LED Handlamp Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Wolflite XT Rechargeable Handlamp exploits advanced technology to deliver excellent performance,

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

TMH 15000/5. 15TE / 5F Air Hoist 1:5 DRG /11/ ,5 313,5 1 / 1. If In Doubt Ask REVISION HISTORY. Part Number.

TMH 15000/5. 15TE / 5F Air Hoist 1:5 DRG /11/ ,5 313,5 1 / 1. If In Doubt Ask REVISION HISTORY. Part Number. D-AH REV ITEM QTY PART NUMBER DRG 7 DRG 7 TMH PARTS LIST DESCRIPTION Top Block Bottom Block Air Hoist (with Lever Plate DRG 7 ) REV. REVISION HISTORY REV. DATE APPROVED : Scale Designed By Drawn By Checked

More information

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Intrinsically Safe Explained Ha ardous Area Classification Zone 0, Zone, Zone This diagram shows

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

Flameproof Level Sensor (Flameproof F/S FP)

Flameproof Level Sensor (Flameproof F/S FP) The Deeter F/S FP is magnetic float on a reed switch or Hall Effect sensor stem for control and indication of a liquid level while in a potentially explosive atmosphere. II 1/2G 2D Ex d IIC (*) Ga/Gb Ex

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing

T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing Capacities 2t to 20t Stainless Steel Load Sensor OIML C3 approved Integrated Lift Off Prevention Load cell is always in Tension

More information

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250, Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves

More information

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s.   PEGAS E Smart Manual EN 04 WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...

More information

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres BROCHURE Low voltage motors and drives for applications in explosive atmospheres 2 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS

More information

OPERATION AND MAINTENANCE INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTIONS ATEX LED WORKLITE WL-85, WL-80 OPERATION AND MAINTENANCE INSTRUCTIONS CONTENTS EU Declaration of Conformity 3 Approval Codes/Certification 3 IECEx Scheme Certification 3 Special Conditions of Use (X Condition)

More information

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2562179B REV. B 818 Printed in USA 2013-2018 Federal Signal Corporation. All rights reserved. Limited Warranty

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0) Data Sheet SCHISCHEK EXCOS-P Pressure sensor 20 Pa... 7.500 Pa Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof

More information

Compact Scales. Software Revision V1.25 & above

Compact Scales. Software Revision V1.25 & above Compact Scales Software Revision V1.25 & above 2016 1 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase:

More information

Flameproof Enclosures

Flameproof Enclosures Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical

More information

2/2 Solenoid Cartridge Valve, Size 6

2/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Mini temperature switch Stainless steel switch enclosure Model TXS

Mini temperature switch Stainless steel switch enclosure Model TXS Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10. BATTERY MODULE Long Life Battery: 10 to 12 Years According to EUROBAT Small Mounting Footprint Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included 3 Year Warranty,

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

DIGITAL BATTERY TESTER 12V

DIGITAL BATTERY TESTER 12V INSTRUCTIONS FOR DIGITAL BATTERY TESTER 12V MODEL NO: BT103 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE 24V, 7Ah Battery Capacity (2x 12V Batteries in Series) Small Mounting Footprint 2m Power Leads Included PT1000 Sensor for Battery Module Temperature Included Includes a Center-tap Terminal

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002 Adam Equipment QT SERIES ADAM EQUIPMENT CO. LTD. pn. 3938 Rev. D1, July 2002 Adam Equipment Co. Ltd. 2002 Adam Equipment Co. Ltd. 2002 FEATURES Auto shut off Auto zero tracking Auto backlight (optional)

More information

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

Adam Equipment LHS SERIES. (P.N , Revision A March 2012) Adam Equipment LHS SERIES (P.N. 7.00.6.6.0200, Revision A March 2012) Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS...1 2.0 INTRODUCTION...2 2.1 INTRODUCTION...2 2.2 TECHNICAL SPECIFICATIONS...3

More information

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas 09005886 DB_EN_MA15_ATEX Rev. ST4-D 03/18 *09005886* Data sheet MA15F... A/B/C/D Diaphragm manometer for explosive areas Gas explosion protection zone 1 and 2, gases and vapours Dust explosion protection

More information

LEAD ACID BATTERY CHARGER

LEAD ACID BATTERY CHARGER LEAD ACID BATTERY CHARGER MODEL NO: LA4 & LA6 OPERATION & MAINTENANCE INSTRUCTIONS LS1214 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger. Please read this manual thoroughly, before attempting

More information

Clarius EP PLUS LED FLOODLIGHT Installation Guide

Clarius EP PLUS LED FLOODLIGHT Installation Guide Clarius Clarius EP PLUS LED FLOODLIGHT Installation Guide CERTIFICATION: SIRA09ATEX5159X AND IECEx SIR 09.0064X AND ABS 11-LD801943-PDA II 2 G D Ex emb IIC T4 Gb Ex t IIIC T103oC Db IP66/67 T4-20 oc to

More information

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use. User Instruction Manual Oxford Classic Digital To avoid injury, read user manual prior to use. Oxford English Contents 1. Introduction: About Your Scale... 3 2. Assembly and Commissioning Instructions...

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS

More information

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA Mechatronic pressure measurement Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA WIKA data sheet PV 34.38 Applications Pressure monitoring and control of processes

More information

Flameproof Alternators

Flameproof Alternators Overview Standard automotive type alternators are a continuous potential source of ignition when operated in hazardous atmospheres where combustible concentrations of gas, vapor or dusts may exist. To

More information

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter INSTRUCTIONS FOR 500A Lithium Jump Starter Stock No.15067 Part No.LJS136 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These

More information

POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE

POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE Power POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE (AI365 Rev 7 15Nov16) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. UK Sales: +44 (0) 161 830 6698 Technical:

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

EX Series User Manual

EX Series User Manual MODELS: EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS EXIN LIGHT EX & INDUSTRIAL LIGHTING EX Series EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS Contents 0. Introduction

More information

SERIES R - MD MOR & GOR

SERIES R - MD MOR & GOR SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling

More information

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide User Guide Crane Forks Introduction Fully self levelling, even when unloaded, Conquip Crane Forks have been designed to lift packs of bricks and pallets. The crane attachment has adjustable forks and a

More information

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors

More information

CCAI, CCAIF, CCAIF..H

CCAI, CCAIF, CCAIF..H CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside

More information

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components T29 series Wash Down S cale Technical Manual TotalcompR Scales & Components T29 Series Technical Manual Manufacturer Model Report No Applicable Standards Totalcomp Inc. T29 ASZ091201012S-2 IP65 Totalcomp

More information

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1 This document hosted by: www.oldwillknottscales.com Adam Equipment SHS/SHSa SERIES (P.N. 7.00.6.6.0202, Revision B November 2012) Software version S1.1/SA1.1 Adam Equipment Company 2012 1.0 CONTENTS 1.0

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

Type 4-20mA Absolute Shaft Encoder & Optional Dragon Flow Sensor DLS-00X User Manual. hohner OPTICAL ENCODERS

Type 4-20mA Absolute Shaft Encoder & Optional Dragon Flow Sensor DLS-00X User Manual. hohner OPTICAL ENCODERS Type 4-20mA Absolute Shaft Encoder & Optional Dragon Flow Sensor DLS-00X User Manual hohner OPTICAL ENCODERS Hohner Corporation 5536 Regional Road 81 Beamsville, Ontario Canada L0R 1B3 Canada Tel: 1 -

More information

15T Low Headroom Hoist TNC 15/3 LHR DRG /02/ / 1. If In Doubt Ask REVISION HISTORY. Part Number. 700kg Weight D01-AHT33 REV0

15T Low Headroom Hoist TNC 15/3 LHR DRG /02/ / 1. If In Doubt Ask REVISION HISTORY. Part Number. 700kg Weight D01-AHT33 REV0 REVISION HISTORY REV. DATE APPROVED D-AHT REV Part Number DRG Scale not to scale Designed By Title of Part Drawn By Checked By Approved By Surname T. Mikolajewski T. Mikolajewski B. Aitken Title of Project

More information

What is the secret to our success?

What is the secret to our success? Australia s Quality Load Cell Manufacturer For over 20 years Delphi has been a reliable source of tension load measurement solutions... What is the secret to our success? TENSION CELLS Delphi Measurement

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Motors and drives for applications in explosive atmospheres

Motors and drives for applications in explosive atmospheres Motors and drives for applications in explosive atmospheres Certification. Diligence. Reliability. Safety. Everything counts Operating processes in explosive (Ex) atmospheres requires the right mix of

More information

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide User Guide Crane Forks Introduction Fully self levelling, even when unloaded, Conquip Crane Forks have been designed to lift packs of bricks and pallets. The crane attachment has adjustable forks and a

More information

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018

More information

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2

More information

Defender 3000 Series Base Instruction Manual

Defender 3000 Series Base Instruction Manual Defender 3000 Series Base Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compliance This product conforms to

More information

VSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.

VSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool. VSM480 VARIABLE SPEED MIXER Instruction Manual Read instructions before operating this tool. Important Please read these operating and safety instructions carefully and completely. For your own safety,

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

1. Introduction Specifications Operation Guide Trouble shooting Note... 13 Content 1. Introduction...1 Notice...1 Safety Guide...1 2. Specifications...2 Features...2 Specifications...3 Capacity and Resolution...4 Schematic Diagram...4 Dimension...5 3. Operation Guide...6 Power

More information

JBL VTX-V20-DF SUSPENSION MANUAL

JBL VTX-V20-DF SUSPENSION MANUAL JBL VTX-V20-DF 1 Contents JBL VTX-V20-DF... 1 IMPORTANT SAFETY WARNING... 3 APPLICATION OF V20-DF... 7 ATTACHMENT OF V20-DF TO V25-II / V25-II-CS... 8 JBL VTX SERIES SUSPENSION PRECAUTIONS AND SAFETY INFORMATION

More information

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other

More information

Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

Load cells. Data sheet. Special features. Cable assignment (six wire configuration) HLC A1 HLC B1 HLC F1 Load cells Special features - Hermetically encapsulated (IP68) - Maximum capacities: 110 kg... 10 t - Rust resistant materials - Low height of construction - Meets EMC requirements

More information

CONTACTS RELAY TESTER 66249

CONTACTS RELAY TESTER 66249 RELAY TESTER 66249 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder

More information

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification able C-1/E Replaces E1-2/E Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - AE or IECEx certification Main poppet Valve main body Mechanical pressure limiter Cover

More information

Compact differential pressure switch Models DC, DCC

Compact differential pressure switch Models DC, DCC Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes

More information

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459, Hydraulic Bottle Jacks 04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459, 82132. These instructions accompanying the product are the original instructions. This document

More information