DIN Rail DC UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Size: px
Start display at page:

Download "DIN Rail DC UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual"

Transcription

1 DI ail DC US DC US/attery Detection System odel: DS-DI-US 2-0 Installation/peration anual able of Contents Section age Section age ) verview/quick Start 2-3 2) General Information 3 aterials rovided 4 ptional quipment 4 3) Safety Information 4 4) Installation/Wiring 4 A) ounting 4 ) Wiring 5. Diagram 2. Input 5 3. utput 5 C) Alarm Contacts, Form C 5 D) emperature Compensation Sensor 5 5) Settings/rogramming 6 A) attery ype/charge Curve 6 ) ime Charge Current imit/attery Charge evel 7 C) System Settings 7 6) peration 8 A) attery Start w/o resent ush utton 8 ) Status Indicator D s 8 C) VD 8 7) rotection 8 8) Specifications/Dimensional Drawing 9 9) roubleshooting 0 0) Warranty 0 -DSDIUS20 AS F ox hone: ail: techservice@newmarpower.com

2 ) verview/quick Start Figure : Function/Wiring verview F F U AD AY C A a b I AX AY CHAGIG V i FAI W AY AY DIAGSIS AY SA FAI H ( (2 (3 D c W AY AY (74) techservice@newmarpower.com CA USA CIFI FAI C C DS DI-US 2-0 IU: 5-230Vac UU: 2Vdc 0A F3 A) Input V: Wire Input lock (lettered left to right) a) Hot b) eutral c) arth Ground ) attery utput: one terminal each for plus and minus. See page 5 for details. C) attery Charge Current imit: Allows setting maximum current flow to battery during recharge cycle, use when low amp-hour batteries are applied to system to prevent overheating when recovering dead batteries. Adjustment range 20-00% of available charge current. (Available charge current = unit output rating of 0 amps - load demand. ote : he unit has a load priority circuit, all produced power is made available to the load, remaining power is available for battery charging). See page 7 for details. ote 2: If enabling the battery test feature which alerts the user to a battery problem (see table, attery est n ), the attery Charge evel adjustement must be set at 0-20% of battery amp/hour capacity in order for the DI US to accurately diagnose a battery fault. D) attery emperature Sensor (optional): lug in port (J-45). See page 6 for details. ) utput to oad: he unit has a load priority circuit, all produced power is made available to the load, remaining power is available for battery charging. See page 5 for details. F) Form C Contacts: Activate upon: F. ower Fail F2. ow attery: (.25V DC) F3. Charger ower Circuit Fail See page 5 for details. 2 G) System Settings: via plug-in jumper programing terminals located on bottom of the unit. a. Install jumper per illustration below (able ) to: i. Select fl oat voltage per attery ype and enable Absorption Charge (see page page 7 for details) See page 8 for details on functional settings. H) Status Indicator D s. ower Fail: perating on battery back-up power (D n). D extinguishes when is present. 2. ow 70% discharge point, i.e. 30 capacity remains 3. Charger utput Status and Fault ode Diagnosis: by blink code: Charge Status link Code: ulk: 5 blink/second - ecovery Absorption: 2 blink/second - ulk Float: blink/second Fault ode Diagnosis link Code: everse olarity: blink, pause attery ot Connected: 2 blink, pause verload or Short Circuit: 4 blink, pause ow battery alarm: steady on, 5 blink, pause ad hermal Sensor: 7 blink, pause and diagnostic See page 9 for details. I) attery Start w/o resent ush utton: If system shuts down due to loss of and battery, pressing this push button will allow battery to reconnect and supply the load if suffi cient battery voltage is present... ox hone: ail: techservice@newmarpower.com

3 ounting DI DC US to DI ail emoving DI DC US from DI ail A A wist wist Insert flat head screwdriver in slot of bottom tab and twist to extend bracket able : System Settings: attery Selection/Absorption Charge and Functional Settings attery ype Selection Float Charge/ Jumper Insert osition Absorption Charge naable/ Jumper Insert osition pen ead (Default) one 3.4 VDC os. 6 Sealed ead ow Insert Jumper: os. os. os VDC Sealed ead High Insert Jumper: os. 2 os. 2 os VDC Gel attery Insert Jumper: os. 3 os. 3 os VDC * ote, voltages above are at 20 C with no battery temperature sensor connected. 2) General Information his DI rail mount DC US Combines all system power functions: power supply, battery charger, US circuitry and status monitoring in one compact unit that produces 2 volt, 0 amps allocated via outputs for load and battery: oad output: load priority distribution ensures power is dedicated first to the load, with remainder then allocated to battery charging, thus preventing a discharged battery from impacting operation of critical loads. attery output: 3 step charging for rapid battery recovery, programmable for battery type, with optional temperature compensation sensor attery automatically on line to support load anytime fails ow voltage disconnect protects battery from total discharge High operating temperature range to 70 C 3.. ox hone: ail: techservice@newmarpower.com

4 his DC US is fitted with special monitoring and alarm features designed to comply with the latest codes related to public safety in-building wireless communications back-up power requirements, as set forth by FA, section 22, In normal operation, the unit supplies power to the transmitter/antennas and maintains the back-up battery. Should an event occur that could cause interruptioin in power, self-diagnosis signals are sent via form C contacts notifying the network operators the system is running in a critical power condtion and that potential communications failure is imminent. ) Fail 2) ow battery voltage indicating battery discharged by 70% (i.e. 30% capacity remaining) 3) Internal charger/power circuit fail aterials rovided: ea. DI-US unit with integral DI rail mount clip 3 ea. Jumper tabs for programming ools equired Small /8 wide Flat Head screwdriver for terminal block connectors arge /4 wide Flat Head screwdriver for disengaging DI ail clip ptional quipment: emperature Compensation Sensor, /: ) Safety Information WAIG xplosion Hazard. Do not disconnect loads or battery unless input and battery have been switched off. WAIG xplosion Hazard. his product is not certifi ed for Class, Div 2 applications. WAIG Switch off or remove input and battery power before wiring the DI-US 2-0. ever work on the DI US when it is connected to input and battery. he DS-DI-US must be installed in accordance with U508 or local electrical codes depending upon the application. he DS-DI-US should have a suitability sized input circuit breaker feeding its input. See specifi cation section for maximum input draw for your input voltage for circuit breaker sizing. CAUI: Hot surface. Avoid touching the DI US case while operating at or near its full load capacity. emove and battery power and allow DS-DI US at least 0 minutes to cool before removing from DI ail. 4) Installation/Wiring A) ounting: he unit is designed for 35 mm DI rail mounting in an enclosure or on a rackmounted DI ail bracket and relies on convection (free air) cooling, thus must have a minimum of 4 (0 cm) of open space above and below the DS-DI-US in order to assure suffi cient air flow. We recommend approximately /2 (0mm) spacing between adjacent DI ail mounted devices. ote, that depending on the ambient temperature and load of the device, the temperature of the case can become hot to the touch. he unit is designed for vertical mount (+/- 5 ) and has an integral clip on the back to secure it to the rail. o mount, place the top tabs over the top of the DI rail, and using a long slotted screw driver insert it in the groove at the bottom of the bracket and twist which will extend the spring loaded mounting bracket downward allowing the unit to be positioned against the DI rail, release the bracket with DS-DI-US positioned vertically and the rail will be captured and the unit secured. Figure 2: ounting Figure 3: emoving A A Insert flat head screwdriver in slot of bottom tab and twist to extend bracket wist wist Insert flat head screwdriver in slot of bottom tab and twist to extend bracket 4.. ox hone: ail: techservice@newmarpower.com

5 ) Wiring Figure 4: Input erminal lock. Input: erminal lock (lettered left to right) - Figure 4 a) Hot/ine: V b) eutral c) arth Ground ecommended wire size: 6 AWG 2. utput CIFI FAI he unit has two outputs: one connects to the oad and the other to the back-up battery. ote: the unit has a load priority circuit, all produced power first is made available to the load with remaining power made available for battery charging. he DI US is isolated from the case, thus you may apply to a positive or negative ground system. a b c attery utput: See page 2, Section G for programming per battery type. utput to oad: terminals for plus and minus. Figure 5: utput erminals oad utput attery utput Fuse note: We recommend a 5 amp fuse or circuit breaker be installed on the hot leg at battery. attery/utput wires size (recommended): 6 AWG erminal lock maximum wire size (recommended): 0 AWG C) Alarm Contacts, Form C (Isolated): U AD AY 5 Form C Contacts for remote monitor: Activate upon: a. ower Fail b. ow attery,.25v DC 70% Discharge oint*, i.e. 30% capacity remains c. Charger/ower Circuit Fail * Applicable to battey systems with 2-5 amp continuous loads with AH capacity able 2: Alarm Contacts Contact Fail D 2 ow attery D elay Contact ating: ax. DC: 30 VDC, amp; : 60 V, amp: esistive load ( ) in.ma at 5 VDC D) ptional attery emperature Compensation Sensor /: Diagnosis D Input FAI only closed open open closed off on 2 link-ause U AY + att closed open closed open off off link/sec AD W AY AY att only open closed closed open on off off AY W AY SA ow att open closed open closed on on off I AX FAI DIAGSIS i AY AY AY * abeled ow attery or attery eplacement on Front anel CHAGIG V SA o install, remove the access tab in the front panel decal labeled AUX ut, Figure 9, install the emp. Sensor into the J-45 connector. Attach sensor to side of battery using DIAGSISCharger/ower i V silicone. Circuit Fail AY Alarm ContactsDS SA he sensor will vary the battery charging voltage depending on the battery s temperature and charge program setting at a rate of 0.08 volts per degree C. FAI W AY AY I A Figure 6: 2 Alarm 3 4 Contacts erminals, Form C (Isolated) U AD I AX AY CHAGIG V Figure 7: Charger/ower Circuit Fail Alarm Contacts AY SA AY FAI C C DI-US 2-0 IU: 5-230Vac UU: 2Vdc 0A W AY AY (74) techservice@newmarpower.com CA USA DS DI-US 2-0 IU: 5-230Vac UU: 2Vdc 0A (74) techservice@newmarpower.com CIFI FAI C C CA USA DS DI-US 2-0 IU: 5-230Vac UU: 2Vdc 0A C (7 techservic ewp CIFI FAI C D I.. ox CIFI FAI C C hone: ail: techservice@newmarpower.com

6 able 3: Absorption Charge Voltage & Float Charge Voltage Settings with emperature Sensor Installed Voltage 2 VDC emperature vs Charging Voltage attery ype - Float pen ow High Gel Fast charge/absorption Figure 8: attery emperature Sensor (74) Access ab, CA USA emperature Sensor Access ab AY SA techservice@newmarpower.com CIFI FAI C C DS DI-US 2-0 IU: 5-230Vac UU: 2Vdc 0A emperature C Formula for determining temperature compensated Float or Absorption voltage based on battery temperature: Float Formula: Float Voltage = (3. * VDC ) (sensor temp. 20 C) (.08 VDC) * see able for Float voltage based on battery type selected xample Conditions attery selection jumper installed for 3.6 VDC Sealed ead High Float voltage attery temperature = 60 C Float voltage = (3.6 VDC) (60 C 20 C) (.08 VDC) = (3.6 VDC) (40 C x.08 VDC) = 3.6 VDC.72 VDC = 2.88 VDC 60 C Fast Charge/Absorption Formula: Fast Charge Voltage = () (sensor temp C) (.08 VDC) xample Conditions: Fast charge/absorption: 4. 4 VDC (same for all battery type selections) attery temperature = 60 C () (60 C 20 C) (.08VDC) = () (40 C x.08 VDC) =.72 VDC = 3.68 VDC 60 C If the battery temperature is less than -20 C or greater than +60 C, an outside its range (temp. sensor) alarm is signalled with 7 blink code. 5) Settings/rogramming A) attery ype/charge Curve Charge curve per battery type: via programing jumpers insterted on bottom panel of unit right side Using programming jumper tabs provided and a small needle nose pliers, insert programming jumpers to select fl oat voltage and enable absorption voltage per per battery type. Caution do not program unit while connected to power. 6.. ox hone: ail: techservice@newmarpower.com

7 Figure 9: attery ype rogram Selection AY SA CIFI FAI C C DS DI-US 2-0 IU: 5-230Vac UU: 2Vdc 0A able 4: attery Selection/Absorption Charge Jumpers Insert jumper tabs for battery selection on bottom panel. 3.4 VDC attery ype Selection Float Charge/ Jumper Insert osition Absorption Charge naable/ Jumper Insert osition pen ead (Default) one 3.4 VDC os. 6 Sealed ead ow Insert Jumper: os. os. os VDC Sealed ead High Insert Jumper: os. 2 os. 2 os VDC Gel attery Insert Jumper: os. 3 os. 3 os VDC * ote: voltages above are at 20 C with no battery temp. sensor connected. Figure 0: Current imit/ ) attery Charge Current imit/attery Charge evel attery Charge evel - Dial Allows setting maximum current fl ow to battery during recharge cycle- use when low amphour batteries are applied to system to prevent overheating when recovering dead batteries. Adjustment range 20-00% of available charge current. (Available charge current = unit output rating of 0 amps minus load demand. ote: the unit has a load priority circuit, all produced power is made available to the load, remaining power is available for battery charging). ote, if enabling the battery test feature which alerts the user to a a battery problem (see able, attery est n ), the attery Charge evel adjustment must be set at 0-20% of battery Amp Hour capacity in order for the DI US to accurately diagnose a battery fault. o set, use small slotted screw driver to rotate selector dial to desired setting. C) System Settings Via plug-in jumper, programming terminals located on bottom right of the unit. Install jumper per illustration below to nable attery est. able 5: Functional Settings Function Setting attery est Insert Jumper: os os. 4 Insert jumper at position 4 to enable eriodic attery condition test process. (Fault reported by D diagnosis blink code, see able 6): attery wiring connection attery efficiency/sulfation (impedance test) Shorted Cell 7.. ox hone: ail: techservice@newmarpower.com

8 6) peration 7 8 A) attery Start without resent ush utton: If the system shuts down due to loss of and battery power, pushing button will allow battery to come Uon AY line to supply AD the load. ress and hold for 3 seconds to re-connect battery to output. ote, if VD has activated and battery voltage has not recovered above disconnect point, the unit will not cycle on. FAI ) Status Indicator D s. ower source: ains or back up i. K ( Fail D ff) or Fail ii. perating on battery backup power ( Fail D n) red 2. ow battery, or battery replacement D illuminates when: ow 70% depleted (.25V DC), i.e. 30 capacity remains 3 diagnosis D. 3. Charger output status system diagnosis and Fault mode diagnosis: by blink code (able 6 below). able 6: Status Indicator Ds onitoring Control State D Diagnosis (o.8) D attery Fault o.7) Charging ype System Auto Diagnosis Float link/sec FF Absorption 2 link/sec FF ulk 5 link/sec FF everse polarity or link/pause* high battery Voltage attery ot connected, 2 link/pause no output power ver oad or short 4 link/pause circuit on the load ow battery: 45.6 volts 5 link/pause emp. Sensor outside 7 link/pause its range oost condition; battery 8 link/pause discharge after 4 min. of overload. Internal fault 9 link/pause Figure : Status Indicator Ds 2 3 i FAI W AY AY DIAGSIS AY SA C ( techservic ewp CIFI FAI C D * ause: Second ow battery detected when system activated by battery start button with no ac input 0 link/pause 8 C) VD he unit contains a low voltage load disconnect that activates at 9 volts (.5 vpc) which is factory set and cannot be user modifi ed. 6) rotection n the Input: the device is equipped with an internal fuse. If the internal fuse is blown, it is most probable that there is a fault in the unit. If this occurs, the unit must be returned to the factory. n the DC uput attery and oad: he device is electrically protected. everse polarity: the module is automatically protected against reverse of battery polarity and connection of reverse polarity... ox hone: ail: techservice@newmarpower.com

9 ver current and output short circuit: the unit limits the output current. ow voltage disconnect protects battery from deep discharge. hermal rotection perating temperature range -2 to 70 C. Unit will produce full rated power on continuous basis to 50 C, however; system load must be reduced by 2.5% per for continuous operation above 50 C. If the temperature reaches 70 C, the unit will reduce its maximum output to approximately 50% of its rating. If the temperature exceeds 70 C, the unit will shut off and restart once temperature drops. 8) Specifications Input: Voltage: , hz Amperage: 20 V 230 V utput: 2 volts, 0 amps total available to power loads and charge battery, with load priority distribution. eak: 30 amps 4 seconds (with battery power boost) ow Voltage Disconnect oint: 9 VDC utput ground isolated from case, may be used in positive ground applications. VD function is lost Front anel D Indicators: ower Source: operating on back up red Fail D attery and System Diagnostics (via blink code) Settings/Selectors: attery ype: AG, Sealed ead Acid, Gel-Cell attery Charge Current imit: 20-00% of charge amperage rating Alarm Contacts (form C): Active: Fail (on battery back-up) ow attery.25v DC: indicating 70% battery discharge point (i.e. 30 capacity remains based on 2-5 amp continuous load on AH battery) Charge Fail contacts perating emperature: -2 to 70 C. Continuous to 50, de-rate 2.5% per C >50 C Cooling: Free air convection fficiency: 50% load Humidity: to 95%, to 25 C rotection: ow Voltage disconnect at.5 volts per cell (9 VDC) Internal fuse Current limiting Short circuit everse polarity hermal overload shut down and recovery I 20 Case Size: 4.5 H x 2.6 W x 5.3 D Design Standards: C ark Designed to U 950 erminal locks: Screw type ounting: DI ail racket 35 mm 9.. ox hone: ail: techservice@newmarpower.com

10 9) roubleshooting Symptom ossible Cause Corrective Action A. attery requires excessive re-charge time. oad turns off after a couple of seconds when running on battery. oad at or near max. recommended load providing minimal current available for charging 2. Charging level current set to low. atteries not charged, due to high load demand. educe load or split load between two separate DI US units 2. Adjust attery Charging evel control knob to higher level. educe load or split load between two separate DI US units C. o absoprtion voltage. Absorption jumper not installed. Install provided jumper in position 5 D. rips input breaker. shorted to case. Verify correct input wiring 2. Defective unit 2. Contact technical service. DC output wired backwards or shorted. emove input and check DC wiring 2. o input 2. Verify correct input. o output 3. xcessive temperature or 3. Improve ventilation, unblock vent holes blocked ventilation 4. Defective unit 4. Contact technical service F. o voltage on battery output terminals. o battery installed (voltage required for battery output to turn on) 2. issing or blown battery wiring fuse. Install batteries 2. eplace missing or blown battery wiring fuse G. Diagnosis Ds always blinking. ormal operation. efer to Chart 2: Diagnosis able 0) Warranty ewmar warrants that the DS-DI-US 2-0 DI ail DC US/attery Detection System to be free from defects in material and workmanship for two years from date of purchase. If a problem with your DS-DI-US 2-0, or if you have any questions about the installation and proper operation of the unit, please contact WA s echnical Services Department: hone: From the hours of 7:30 a.m. to 5:00 p.m. weekdays,.s..; -mail: techservice@newmarpower.com 0.. ox hone: ail: techservice@newmarpower.com

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual DI Rail US Model: DI-US 48-5 Installation/Operation Manual Table of Contents Section age Section age Quick Start 2 1) General Information 4 Materials rovided 4 Optional quipment 4 2) Safety Information

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail US odel: DIN-US 12-5 Installation/peration anual Table of Contents Section age Section age Quick Start 2 1) General Information 4 aterials rovided 4 ptional ccessories 4 2) Safety Information

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS!

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS! RAD AD FLLW ALL SAFTY ISTRUCTIS! SAV THS ISTRUCTIS! IMRTAT SAFGUARDS RAD AD FLLW ALL SAFTY ISTRUCTIS. Do not use outdoors. Do not let power supply cords touch hot surfaces. Do not mount near gas or electric

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER INSTRUCTION MANUAL FILE: IM_091-120-XX-XX-(XXX)(XX)_revA.P65 REV: A REVISED BY: PSS DATE: 07-19-13 AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER R MODEL #091-120-XX-XX-(XXX)(XX) 3 YEAR WARRANTY 170 Cherry

More information

INSTRUCTION MANUAL CAUTION

INSTRUCTION MANUAL CAUTION FILE: IM_091-128-12E-40-115 Rev B., 2-16-2006 INSTRUCTION MANUAL AUTO CHARGE ODY q AUTOMATIC BATTERY CHARGER MODEL #091-128-12E-40-115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

SBC / 2140 / Stage Battery Charger User Manual

SBC / 2140 / Stage Battery Charger User Manual SBC - 2130 / 2140 / 2150 3 Stage Battery Charger User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

Power Distribution System User s Manual. Model: PDS-100

Power Distribution System User s Manual. Model: PDS-100 Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...

More information

Installation Instructions

Installation Instructions AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in

More information

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101194 Document revision: D DCN number: 105128 Date: 3/23/2006 1840 Industrial Circle Longmont, CO 80501 Fax: 303-678-7504 Tel: 303-678-7500

More information

All In one uninterruptible power supply solutions

All In one uninterruptible power supply solutions All In one uninterruptible power supply solutions For the life of your systems with Battery Care concept Integrated Electronic Solution Yet another strong proposition from Adelsystem, result of the continuing

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

CBI All in One DC UPS Power Solutions

CBI All in One DC UPS Power Solutions CBI All in One Power Solutions Everything and more! More efficiency of the battery thanks to continuous control over time. More monitoring in main connection nodes: input, output load, battery. Event logging:

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.

More information

Pure Sine Wave Inverter Charger

Pure Sine Wave Inverter Charger Pure Sine Wave Inverter Charger Renogy 1000W 2000W Pure Sine Wave Inverter Charger Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.6 1 Important Safety Instructions Please save

More information

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY SMT WITH MPPT TECHNOLOGY Installation and Operation Manual Model:SMT SMT Dimensions Specification Summary System Voltage 12 V/24V Rated Battery Current 12V, 5A 8A 10A 15A 20A 25A 24V, 5A 8A 10A 15A Rated

More information

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 4000 LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER Unit supplied with this display MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 45 Amps File:

More information

Intelligent Charging System Series

Intelligent Charging System Series R Intelligent Charging System Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models Amperage No. Of Banks Volts 16061 s 1 Bank 12 16102 6,s 2 Banks 12 or 24 16153 6,6,s 3 Banks 12 or 24 or 36 16202 10,10

More information

CX Series User s Manual

CX Series User s Manual CX Series User s Manual Advanced Converter / Charger Legal Provisions Copyrights 2016 COTEK Electronic IND. CO. All Rights Reserved. Any part of this document may not be reproduced in any form for any

More information

Eclipse Solar Suitcase

Eclipse Solar Suitcase Eclipse Solar Suitcase Renogy 100W 200W 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.0 Important Safety Instructions Please save these instructions. This manual contains important

More information

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct

More information

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating 530-101760 REV C 0808-03C December 7, 2012 Westell FUSE PANEL Technical Practice 180108-N-0808 8 Position Type 70 130 VDC Floating FEATURES Single floating input distributing power via Type-70 fuses each

More information

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

FUM-24xxCBP Series 3 Stage Battery Charger User Manual FUM-24xxCBP Series 3 Stage Battery Charger User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct use

More information

Installation Instructions

Installation Instructions Installation Instructions AQU243-8C1R -8F8R -8C8R 24VDC/3.3Amp Supervised (AC & Battery) Power Supply/Charger Module, 85-264vac, 14 x 9 x 3.5" Enclosure, UL294, UL603 & UL1481 Listed AQU243 with one PDB-8C1R

More information

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in

More information

AUTO CHARGE LPC SERIES

AUTO CHARGE LPC SERIES INSTRUCTION MANUAL FILE: IM_091-206-12_revB REV: B REVISED BY: THN DATE: 09-17-2012 AUTO CHARGE LPC SERIES MODEL #091-206-12 LPC STANDARD DISPLAY INPUT: 115 volt, 50/60 Hz, 13 amps OUTPUT: 80 AMPERES 3

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller Rover Series Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller 0 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.5 Important Safety Instructions Please save these

More information

AC CONVERTER / BATTERY CHARGER

AC CONVERTER / BATTERY CHARGER AC CONVERTER / BATTERY CHARGER User s Manual MODEL #: CON120AC12/24VDC Listed to UL 458 and CSA 22.2 NO. 107.1 Standards Contents INTRODUCTION... 3 Important Safety Instructions... 3 1. General Description...

More information

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,

More information

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL 7 Stage Automatic Smart Battery Charger Desulphuration& Maintainer (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1 IMPORTANT

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. IntelliCharge Battery Charger Series INSTRUCTION MANUAL 855-342-000 Models: ICT24012-30BC2, ICT24012-30BC2M ICT24012-15BC2, ICT24012-15BC2M ICT24024-15BC2, ICT24024-15BC2M

More information

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. PD9100 / 9200 SERIES POWER CONVERTER OWNERS MANUAL PROGRESSIVE DYNAMICS, INC. POWER CONVERTER LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power converter to be free from

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries DESIGNED FOR WORKSHOPS AND WAREHOUSES User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries. THIS MANUAL

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL PUMP PLUS 2000 PLC AUTOMATIC DUAL OUTPUT BATTERY CHARGER Supplied with Dual Bar Graph Display MODEL #: 091-237-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15 or 18

More information

Self-Testing Industrial Series

Self-Testing Industrial Series Series: AS-I (Maint.-Free) Self-Testing Industrial Series Emergency Lighting Equipment Instructions for INSTALLATION OPERATION SERVICE SPECIFICATIONS 1300650 1300654 1300666 1300754 1300823 1300886 Hubbell

More information

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A The Tender Light Weight On- Board 12 Volt, 6 Amp 24 Volt, 3 Amp GENERAL DESCRIPTION: The lightweight, on-board, power tender, battery charger is

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

BS20 BATTERY CHARGER For lead-acid batteries

BS20 BATTERY CHARGER For lead-acid batteries BS20 BATTERY CHARGER For lead-acid batteries User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries. THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

HPP1 MK5 Owner s Manual

HPP1 MK5 Owner s Manual J Wolmarans Page 1 2017/03/07 Page 1 of 10 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Features...3 5 Contents...3 6 Installation...3 6.1 Mounting the unit:...3 6.2 Connecting

More information

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL PUMP PLUS 1000 PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-215-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15

More information

OD10 10A Outdoor Solar Charge Controller

OD10 10A Outdoor Solar Charge Controller OD10 10A Outdoor Solar Charge Controller CHC-OD12-10 User s Manual Page 1 of 14 windynation Revision 2 Table of Contents 1.1 Features...3 1.2 Safety Information...4 1.3 Specifications...4 1.3.1 Electrical

More information

The Power of Reliability INSTRUCTION MANUAL

The Power of Reliability INSTRUCTION MANUAL The Power of Reliability INSTRUCTION MANUAL SAFETY & WARNINGS Read this manual carefully and understand all Warnings and Cautions before connections are made to the Inverter. If unsure about any aspects

More information

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual MAXIMUM POWER POINT TRACKING. Model: SS-MPPT-15L

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual MAXIMUM POWER POINT TRACKING. Model: SS-MPPT-15L SUNSAVER MPPT TM WITH TRAKSTAR TM MPPT TECHNOLOGY Installation and Operation Manual MAXIMUM POWER POINT TRACKING Model: SS-MPPT-15L 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com

More information

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 40 LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-200-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 40

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Spectron Industrial Series

Spectron Industrial Series 1300650 1300654 1300666 1300754 1300823 1300886 Table B Constant Value per Voltage System Wire Size (Maximum Voltage Drop 5%) System 6 Volt 12 Volt 24 Volt Wire Size #12 #10 #8 #6 #12 #10 #8 #6 #10 #12

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

SCCP PWM Charge Controller/Load Manager Owner s Manual

SCCP PWM Charge Controller/Load Manager Owner s Manual SCCP05-050 PWM Charge Controller/Load Manager Owner s Manual NOTE: Follow instructions in order. Charge batteries at least once a week. Use reducers to connect larger wires disconnect to terminals. battery

More information

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + - Instruction Manual Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + - Optional - Switch to disconnect solar panel when engine alternator

More information

Solar Charge Controller

Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Type Battery Type Code SC-600W MPPT Bulk Voltage Floating Voltage Vented 01 28.6 V 26.4 V Sealed 02 28.6 V 26.8 V Gel 03 28.6 V 27.4 V NiCd 04 28.6

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

Duo Battery Charge Controller

Duo Battery Charge Controller Duo Battery Charge Controller RENOGY 10A 20A Pulse Width Modulation Solar Charge Controller Manual 1 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 Version: 1.2 Important Safety Instructions

More information

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This

More information

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL UM LUS 1200 AUTOMATIC SINGLE OUTUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-193-12 INUT: 120 Volt, 60 Hz, 10 Amps OUTUT: 40 Amps File: IM_091-193-12_revH.indd

More information

GCU-10. Automatic Engine Control Unit Operators Manual

GCU-10. Automatic Engine Control Unit Operators Manual GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,

More information

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MODEL ELC-12/40-CVM-D BATTERY CHARGER NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current

More information

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC. USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT Galley Power LLC www.galleypower.com Table of Contents Safety Notice... 3 Disclaimer... 3 Safety Instructions... 4 1. Introduction... 5 1.1 Features and

More information

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET LESTRONIC II BATTERY CHARGER TAYLOR-DUNN 79-301-10 MODEL 13110-32 TYPE 24LC25-8ET AC Supply: DC Output: Battery Capacity: Specifications 120 volts, 60 Hertz, single-phase 24 volts, 32 amps Use only on

More information

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative percentage

More information

BatteryMINDer 1500* & BatteryMINDer Plus 1510*

BatteryMINDer 1500* & BatteryMINDer Plus 1510* BatteryMINDer 1500* & BatteryMINDer Plus 1510* both with SmarTECHnology 12 Volt 1500 ma Charger - Maintainer - Desulfator INCLUDES: Auto-Temp Compensation Sensor, installed (1500 & 1510) Optional Permanent

More information

AccuPower AQU126B Installation Instructions

AccuPower AQU126B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

PM Series Power Module Power Supply/Battery Charger

PM Series Power Module Power Supply/Battery Charger PM Series Power Module Power Supply/Battery harger INSTALLATION / OPERATION MANUAL MODELS: PM-24-80, PM-48-50 Table Of ontents Topic Page QUIK REFERENE ONTENTS 2 I) OVERVIEW 3 II) A POWER QUALITY AND EMI

More information

www.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions. MPPT Solar System Controller ISC3040 Installation and Operating Instructions MPPT Solar System Controller ISC3040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s

More information

GXSeries. User Guide DANGER

GXSeries. User Guide DANGER GXSeries User Guide DANGER PRIOR TO USE, READ AND UNDERSTAND PRODUCT SAFETY INFORMATION. Failure to follow the instructions may result in ELECTRICAL SHOCK, EXPLOSION, or FIRE, which may result in SERIOUS

More information

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester Charge & Testing Integrated Electronic Solutions Connect Multimediality The new ADELSystem platform communication ADELBus

More information

HPP1 MK5 Owner s Manual

HPP1 MK5 Owner s Manual J Wolmarans Page 1 2016/09/15 Page 1 of 9 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Contents...3 5 Installation...3 5.1 Mounting the unit:...3 5.2 Connecting the battery:...3

More information

SureFire SLR Lubricator

SureFire SLR Lubricator Sureire SR ubricator utomatic, Oil eneral he Sureire SR automatic lubricator is a robust and durable pump that can handle oil and soft greases. Its compact size is designed to fit your space requirements

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

AUTO CHARGE 1200 PUMP PLUS

AUTO CHARGE 1200 PUMP PLUS FILE: 091-193-12.pmd REV: B REVISED BY: MFG DATE: 2-14-2011 INSTRUCTION MANUAL AUTO CHARGE 1200 PUMP PLUS AUTOMATIC BATTERY CHARGER MODEL #091-9-1200 INPUT: 115 volt, 50/60 Hz, 10 amps OUTPUT: 40 AMPERES

More information

Informer Compact Series

Informer Compact Series IMPORTANT SAFETY INSTRUCTIONS Informer Compact Series LINE-INTERACTIVE SINEWAVE UPS Uninterruptible Power System WARNING : (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions.

More information