Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

Size: px
Start display at page:

Download "Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A"

Transcription

1 Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A The Tender Light Weight On- Board 12 Volt, 6 Amp 24 Volt, 3 Amp GENERAL DESCRIPTION: The lightweight, on-board, power tender, battery charger is a high frequency switching power converter that has a true DC output at a maximum power level of approximately 70 watts. The most common output voltage and current configurations are defined as models in the title block. Check with the factory for other output voltage and current configurations that may be available. Also, a variety of software configurations are available: Standard; Sealed, VRLA, GRT, AGM (Hawker/Optima); and GEL. OUTPUT CABLE CONNECTIONS: The battery charger is equipped with an SPT-2 type output cable with two output leads. The positive polarity output lead has a 3/8" diameter ring terminal with a red molded polymer insulation cylinder. The negative polarity output lead has a 5/16" diameter ring terminal with a black molded polymer insulation cylinder. The standard unit does not have a quick disconnect output cable harness. Quick disconnect output cable harnesses may be available on a special order basis. The price for units with this modification will be higher than those units shown on the standard price list. The price will depend on the volume purchased. STATUS INDICATOR LIGHTS: The following describes the operation of the status indicator lights: RED - When the red light is on, the battery charger is in the process of fully charging the battery. In order to properly charge large capacity batteries, the charger may remain in this mode for several hours or even days. GREEN FLASHING (Hawker/Optima [Sealed, GRT, AGM] Models only) - When the green light is flashing, and the red light is on, the battery is greater than 80% charged and may be removed from the charger and used if necessary. Leave the Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 1 of 10

2 battery on charge until the green light is solid whenever possible. This will occur approximately 8 hours after the green light begins flashing. GREEN - When the green light is lit, the battery charger is in the storage mode of charge. In this mode the charger will maintain the battery at full charge. If the battery becomes partially discharged due to an external current draw or excessive internal battery losses, the charger will automatically switch itself back to the charge mode of operation. ALTERNATING RED AND GREEN - When the lights switch back and forth, the battery charger is connected to the battery with the polarity reversed. SPECIAL TROUBLESHOOTING INFORMATION: 1) NEITHER OF THE CHARGER STATUS INDICATOR LIGHTS TURN ON: a) Disconnect the charger AC power plug from the AC outlet and recheck that the battery charger alligator clips or ring terminals are connected to the correct polarity battery terminals and that they are making a clean, tight connection. b) Check to make sure that the AC outlet is supplying power by plugging in another appliance like a lamp, or check the outlet voltage with a voltmeter. 2) THE STORAGE/FLOAT MAINTENANCE STATUS INDICATOR LIGHT (GREEN LIGHT) GOES ON IMMEDIATELY WHEN CHARGING A BATTERY KWN TO BE DISCHARGED: a) The battery may be defective. Take the battery to the dealer to be tested. b) The electrical connections between the charger and the battery may not be completely secured. 3) AFTER THE STORAGE/FLOAT MAINTENANCE STATUS INDICATOR LIGHT (GREEN LIGHT) HAS BEEN ON, AND THE AC POWER IS REMOVED FROM THE CHARGER AND THEN IMMEDIATELY RECONNECTED, IT SEEMS TO TAKE TOO MUCH TIME FOR THE GREEN LIGHT TO COME ON AGAIN. a) This is RMAL OPERATION for the LWOB Power Tender. b) Whenever AC power is removed from the charger, including momentary AC power outages, the charge cycle resets. Therefore, depending on the software version, several hours may elapse (8 hours on the Sealed, VRLA, GRT, AGM, Hawker, Optima) before the green light stops flashing. 4) AFTER THE STORAGE/FLOAT MAINTENANCE STATUS INDICATOR LIGHT (GREEN LIGHT) HAS BEEN ON, THE RED LIGHT COMES ON. a) This is RMAL OPERATION for the LWOB Power Tender. b) There has been a momentary AC power outage that reset the charge cycle. c) There is some other load or appliance drawing power from the battery. When the battery voltage drops below 12.0V to V (on 12 volt models), the charge cycle resets. Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 2 of 10

3 Lightweight On Board (Power Tender) 12V, 24V, STD Charger Specification Summary SOFTWARE: STANDARD Deltran Part Number: , , -2 Nominal Output: : 12 Volts 24 Volts : 6 Amps 3 Amps Input : with 1 part number suffix 90 to 132 VAC (Factory Selectable) with 2 part number suffix 180 to 264 VAC Input Frequency: 47 to 62 Hz Maximum Input : VAC VAC Nominal Efficiency: 80% Nominal Power Factor: 0.6 Charger Output: Maximum 25 C 70 Watts (+2, -5) Watts Maximum : 6.0 Amps 3.0 Amps During Bulk Charge (+/- 10%) (+/- 10%) Absorption : 14.5 VDC = (2.42 vpc) 28.8 VDC = (2.4 vpc) Absorption to Float Charge drops: below 3.0 Charge drops: below 1.0 Amp. Amps. Equalization : NA Float : 13.2 VDC = (2.2 vpc) 26.4 VDC = (2.2 vpc) Charge Reset: Threshold: 12 to VDC (2 to 2.08 vpc) 24 to 24.5 VDC (2 to 2.04 vpc) Output Regulation: Line (Typical): 1% Electrical Isolation: Input / Output: Input / Chassis: Output / Chassis: 500 VAC Operating Temp: -20 C to 50 C Dimensions: 5 in(127)l x 4.9 in(125)w x 2 in(51)h Weight: 21 oz. Carton Size: 6 in(153 mm)l x 6 in(153 mm)w x 6 in(153 mm)h Shipping Weight: 2 lbs. Enclosure: Powder Coated Aluminum Chassis Special Features: Short Circuit Protection: Reverse Polarity Protection: Spark Proof: Temperature Compensation: Agency Listings: UL, ETL, CSA, etc. Selected models are listed to UL-1236 and CSA 22.2 Contact the office in DeLand, FL for information on agency listings. Phone: Table 1 Spec Sheet: LWOB Power Tender (12V, 24V Standard) Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 3 of 10

4 Lightweight On Board (Power Tender) 12V, 24V, AGM Charger Specification Summary SOFTWARE: Sealed/VRLA/GRT/AGM (Valve Regulated Lead Acid / Gas Recombinant Technology /Absorbed Glass Matte) Deltran Part Number: , , -2 Nominal Output: : 12 Volts 24 Volts : 6 Amps 3 Amps Input : with 1 part number suffix 90 to 132 VAC (Factory Selectable) with 2 part number suffix 180 to 264 VAC Input Frequency: 47 to 62 Hz Maximum Input : VAC VAC Nominal Efficiency: 80% Nominal Power Factor: 0.6 Charger Output: Maximum 25 C 70 Watts (+2, -5) Watts Maximum : 6.0 Amps 3.0 Amps During Bulk Charge (+/- 10%) (+/- 10%) Absorption : 14.9 VDC = (2.48 vpc) 29.8 VDC = (2.48 vpc) Absorption to Float Absorption Charge Duration is Fixed at 8 Hours. Equalization : NA Float : 13.6 VDC = (2.27 vpc) 27.2 VDC = (2.27 vpc) Charge Reset: Threshold: 12 to VDC (2 to 2.08 vpc) 24 to 24.5 VDC (2 to 2.04 vpc) Output Regulation: Line (Typical): 1% Electrical Isolation: Input / Output: Input / Chassis: Output / Chassis: 500 VAC Operating Temp: -20 C to 50 C Dimensions: 5 in(127)l x 4.9 in(125)w x 2 in(51)h Weight: 21 oz. Carton Size: 6 in(153 mm)l x 6 in(153 mm)w x 6 in(153 mm)h Shipping Weight: 2 lbs. Enclosure: Powder Coated Aluminum Chassis Special Features: Short Circuit Protection: Reverse Polarity Protection: Spark Proof: Temperature Compensation: Agency Listings: UL, ETL, CSA, etc. Selected models are listed to UL-1236 and CSA 22.2 Contact the office in DeLand, FL for information on agency listings. Phone: Table 2 Spec Sheet: LWOB Power Tender (12V, 24V AGM) Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 4 of 10

5 Lightweight On Board (Power Tender) 12V GEL Charger Specification Summary SOFTWARE: GEL Deltran Part Number: , -2 Nominal Output: : 12 Volts : 6 Amps Input : with 1 part number suffix 90 to 132 VAC (Factory Selectable) with 2 part number suffix 180 to 264 VAC Input Frequency: 47 to 62 Hz Maximum Input : VAC VAC Nominal Efficiency: 80% Nominal Power Factor: 0.6 Charger Output: Maximum Power: C (+2, -5) Watts Maximum : 6.0 Amps During Bulk Charge (+/- 10%) Absorption : 14.1 VDC = (2.35 vpc) Absorption to Float Charge drops: below 3.0 Amps. Equalization : NA Float : Charge Reset: Threshold: Output Regulation: Line (Typical): 1% Electrical Isolation: 13.2 VDC = (2.2 vpc) 12 to VDC (2 to 2.08 vpc) Input / Output: Input / Chassis: Output / Chassis: 500 VAC Operating Temp: -20 C to 50 C Dimensions: 5 in(127)l x 4.9 in(125)w x 2 in(51)h Weight: 21 oz. Carton Size: 6 in(153 mm)l x 6 in(153 mm)w x 6 in(153 mm)h Shipping Weight: 2 lbs. Enclosure: Powder Coated Aluminum Chassis Special Features: Short Circuit Protection: Reverse Polarity Protection: Spark Proof: Temperature Compensation: Agency Listings: UL, ETL, CSA, etc. Selected models are listed to UL-1236 and CSA 22.2 Contact the office in DeLand, FL for information on agency listings. Phone: Table 3 Spec Sheet: LWOB Power Tender (12V GEL) Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 5 of 10

6 Light Weight On-Board (Power Tender) 12V6A Models: 12V6A STANDARD: Stage 1) Bulk Charge: Red Light On, Green Light Off, = 5.5 Amps, Transition to Stage 2, Absorption Charge when battery voltage reaches 14.5 VDC. Stage 2) Absorption Charge: Red Light On, Absorption = 14.5 VDC Transition to Float Charge when battery charging current drops below 3.0 amps. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 13.2 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 12.0 to VDC, then the charge cycle restarts Terminal (VOLTS) Light Weight On-Board (Power Tender) 12 Volt 6 Amp DC Output Charging Algorithm STANDARD Charging (AMPS) = 2.42 vpc (14.5 V) Float = 2.20 vpc = 14.5 Volts = 3 Amp (13.2 V) BULK ABSORPTION FLOAT 10 Limit (6 A) Recharge Times shown to Fully Recharge a 16 Ah Pack (3 A) (50 to 100 ma) Charging Time (Hours) Figure 1 Charging Graph: LWOB Power Tender 12V6A STD Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 6 of 10

7 12V6A Sealed/VRLA/GRT/AGM (Hawker/Optima): Stage 1) Bulk Charge: Red Light On, = 5.5 Amps, Transition to Stage 2, Absorption when battery voltage reaches 14.9 VDC. Stage 2) Absorption Charge: Red Light On, Green Light Flashing, Absorption = 14.9 VDC Transition to Float Charge 8 hours after entering stage 2. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 13.6 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 12.0 to VDC, then the charge cycle restarts Terminal (VOLTS) Light Weight On-Board (Power Tender) 12 Volt 6 Amp DC Output Charging Algorithm AGM / GRT Charging (AMPS) = 14.9 Volts = 2.48 vpc (14.9 V) Fixed 8 Hour ABSORPTION Float = 2.27 vpc (13.6 V) After 8 Hour Absorption BULK ABSORPTION FLOAT 10 Limit (6 A) Recharge Times shown to Fully Recharge a 16 Ah Pack (50 to 100 ma) Charging Time (Hours) Figure 2 Charging Graph: LWOB Power Tender 12V6A AGM Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 7 of 10

8 12V6A GEL: Stage 1) Bulk Charge: Red Light On, Green Light Off, = 5.5 Amps, Transition to Stage 2, Absorption Charge when battery voltage reaches 14.1 VDC. Stage 2) Absorption Charge: Red Light On, Absorption = 14.1 VDC Transition to Float Charge when battery charging current drops below 3.0 amps. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 13.2 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 12.0 to VDC, then the charge cycle restarts Terminal (VOLTS) Light Weight On-Board (Power Tender) 12 Volt 6 Amp DC Output Charging Algorithm GEL Charging (AMPS) = 2.35 vpc (14.1 V) = 14.1 Volts = 3 Amp Float = 2.20 vpc (13.2 V) BULK ABSORPTION FLOAT 10 Limit (6 A) Recharge Times shown to Fully Recharge a 16 Ah Pack (3 A) (50 to 100 ma) Charging Time (Hours) Figure 3 Charging Graph: LWOB Power Tender 12V6A GEL Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 8 of 10

9 Light Weight On-Board (Power Tender) 24V3A Models: 24V3A STANDARD: Stage 1) Bulk Charge: Red Light On, Green Light Off, = 3.0 Amps, Transition to Stage 2, Absorption Charge when battery voltage reaches 29.0 VDC. Stage 2) Absorption Charge: Red Light On, Absorption = 29.0 VDC Transition to Float Charge when battery charging current drops below 1.0 amp. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 26.4 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 24.0 to 25.0 VDC, then the charge cycle restarts Terminal (VOLTS) Light Weight On-Board (Power Tender) 24 Volt 3 Amp DC Output Charging Algorithm STANDARD Charging (AMPS) = 2.42 vpc (29.0 V) Float = 2.20 vpc = 29.0 Volts (26.4 V) = 1 Amp BULK ABSORPTION FLOAT Limit (3 A) Recharge Times shown to Fully Recharge a 16 Ah Pack (1 A) (50 to 100 ma) Charging Time (Hours) Figure 4 Charging Graph: LWOB Power Tender 24V3A STD Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 9 of 10

10 24V3A Sealed/VRLA/GRT/AGM (Hawker/Optima): Stage 1) Bulk Charge: Red Light On, = 3.0 Amps, Transition to Stage 2, Absorption when battery voltage reaches 29.8 VDC. Stage 2) Absorption Charge: Red Light On, Green Light Flashing, Absorption = 29.8 VDC Transition to Float Charge 8 hours after entering stage 2. Stage 3) There is no Equalization Charge, Go directly to stage 4. Stage 4) Float Charge: Red Light Off, Green Light On. Float = 27.2 VDC. If an external load is applied to the battery while the charger is in stage 4, Float Charge, and if the battery voltage drops below a range between 12.0 to VDC, then the charge cycle restarts Terminal (VOLTS) Light Weight On-Board (Power Tender) 24 Volt 3 Amp DC Output Charging Algorithm AGM / GRT Charging (AMPS) = 2.48 vpc (29.8 V) Float = 2.27 vpc Fixed 8 Hour ABSORPTION (27.2 V) = 29.8 Volts After 8 Hour Absorption BULK ABSORPTION FLOAT Limit (3 A) Recharge Times shown to Fully Recharge a 16 Ah Pack (50 to 100 ma) Charging Time (Hours) Figure 5 Charging Graph: LWOB Power Tender 24V3A AGM Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL Page 10 of 10

Heavy Duty, Portable, Single & Dual Output DV Chargers: Models: Single: 12V20A Dual: 12V20A

Heavy Duty, Portable, Single & Dual Output DV Chargers: Models: Single: 12V20A Dual: 12V20A Heavy Duty, Portable, Single & Dual Output DV Chargers: Models: Single: 12V20A Dual: 12V20A The Tender Heavy Duty, Portable Dual Output DVD-40 12 Volt, 20 Amp The Tender Heavy Duty, Portable Single Output

More information

High Frequency SMT Golf Car Chargers Battery Tender Battery Charger Models: 12 Volt 20 Amp, 24 Volt 20 Amp, 36 Volt 15 Amp, 48 Volt 10 Amp

High Frequency SMT Golf Car Chargers Battery Tender Battery Charger Models: 12 Volt 20 Amp, 24 Volt 20 Amp, 36 Volt 15 Amp, 48 Volt 10 Amp Deltona Transformer Corporation High Frequency SMT Golf Car Chargers Battery Tender Battery Charger Models: 12 Volt 20 Amp, 24 Volt 20 Amp, 36 Volt 15 Amp, 48 Volt 10 Amp IMPORTANT SAFETY INSTRUCTIONS

More information

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL 7 Stage Automatic Smart Battery Charger Desulphuration& Maintainer (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1 IMPORTANT

More information

SPECIFICATIONS LOW COST 2404R CHARGER

SPECIFICATIONS LOW COST 2404R CHARGER SPECIFICATIONS LOW COST 2404R CHARGER Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 Volts, 2 Amp Constant Current (Equivalent to 4A tapered

More information

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER SONEIL INTERNATIONAL LIMITED 3 180 Advance Blvd., Brampton, Ontario, L6T 4J4 Ph.: 905-565-0360 Fax: 905-799-6821 http://www.soneil.com Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY

More information

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System Designed for Six-cell and three-cell Flooded/AGM/GEL Lead-Acid Batteries and Four-Cell Lithium Iron Phosphate (LiFePO4) Batteries

More information

SPECIFICATIONS SRF

SPECIFICATIONS SRF 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8 e-mail: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS - 2416SRF Totally Automatic

More information

SPECIFICATIONS LOW COST 2404S CHARGER

SPECIFICATIONS LOW COST 2404S CHARGER 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, e-mail: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS LOW COST 2404S CHARGER Totally

More information

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2 TRICKLE CHARGER MODEL NO: ATC12VB PART NO: 6266012 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0618 ISS 2 INTRODUCTION Thank you for selecting this Clarke Trickle Charger. Read this manual

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.

More information

Specification of Soneil Battery Charger

Specification of Soneil Battery Charger SONEIL INTERNATIONAL LIMITED 3 180 Advance Blvd., Brampton, Ontario, L6T 4J4 Ph.: 905-565-0360 Fax: 905-799-6821 http://www.soneil.com Specification of Soneil Battery Charger MODEL: CS3603SR 36V1.2A BATTERY

More information

BRAVO Inverter/Battery Charger. Table of Contents

BRAVO Inverter/Battery Charger. Table of Contents BRAVO 1050 Inverter/Battery Charger Table of Contents Introduction... 2 General Description... 2 Specifications... 3 Installation: Hardwire Units... 4 Operation: Hardwire Units... 5-6 Installation: GFCI

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC Automatic Battery Charger Switching mode with Micro-controlled Input:100-140Vac / Output: 12Volt DC User s Manual and Important Safety Information Model: #20085 (SW121080-06) FEATURES Congratulations on

More information

SPECIFICATIONS SRF SuperchargerPlus

SPECIFICATIONS SRF SuperchargerPlus SPECIFICATIONS - 2412SRF Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 V, 6Amp Constant Current (equivalent to 12A tapered charger in charging

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. IntelliCharge Battery Charger Series INSTRUCTION MANUAL 855-342-000 Models: ICT24012-30BC2, ICT24012-30BC2M ICT24012-15BC2, ICT24012-15BC2M ICT24024-15BC2, ICT24024-15BC2M

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries 8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A Charges & Maintains Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries USER S MANUAL 5 User s Manual And Guide To Professional Battery Charging

More information

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER.

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER. CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER. For your personal safety, read, understand and follow the information provided in this instruction manual and on the battery charger.

More information

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ Owner s Manual Contents 1.0 Installation Overview... 2 2.0 Warnings... 2 3.0 Choosing a Location...3 4.0 Installation Instructions... 3 5.0 Operating Instructions...4 6.0 Frequently Asked Questions (FAQs)...6

More information

SPECIFICATIONS CAA Supercharger

SPECIFICATIONS CAA Supercharger SPECIFICATIONS - 2408CAA Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 V, 4A Constant Current (equivalent to 8A tapered charger in charging

More information

SPECIFICATIONS SR CHARGER

SPECIFICATIONS SR CHARGER 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, Email: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS - 2409SR CHARGER Totally

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This

More information

Battery Booster Pack. Instruction Manual for P/N

Battery Booster Pack. Instruction Manual for P/N Important: Please ensure that you read and save this instruction manual before using this product. Incorrect operation or misuse of this Battery Booster Pack may damage the equipment or create hazardous

More information

AC CONVERTER / BATTERY CHARGER

AC CONVERTER / BATTERY CHARGER AC CONVERTER / BATTERY CHARGER User s Manual MODEL #: CON120AC12/24VDC Listed to UL 458 and CSA 22.2 NO. 107.1 Standards Contents INTRODUCTION... 3 Important Safety Instructions... 3 1. General Description...

More information

Owner s Manual. Contents GP-PWM-10-SQ

Owner s Manual. Contents GP-PWM-10-SQ Owner s Manual Contents 1.0 Installation Overview... 2 2.0 Warnings... 2 3.0 Choosing a Location... 3 4.0 Installation Instructions... 3 5.0 Operating Instructions... 4 6.0 Frequently Asked Questions (FAQs)...

More information

Battery Chargers - Phase Three Series

Battery Chargers - Phase Three Series Battery Chargers - Phase Three Series Three Stage Smart Chargers Phase Three Smart battery charging technology is now available in a wide range of power levels, allowing you to select the right size, features

More information

SPECIFICATIONS SRL CHARGER

SPECIFICATIONS SRL CHARGER SONEIL 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, Email: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at http://soneil.com SPECIFICATIONS - 2403SRL CHARGER

More information

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC Automatic Battery Charger Switching mode with Micro-controlled Input:220-260Vac / Output: 12Volt DC User s Manual and Important Safety Information Model: OC-SW121080 / OC-SW121160 / OC-SW121210 FEATURES

More information

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC Automatic Battery Charger Switching mode with Micro-controlled Input:220-260Vac / Output: 12Volt DC User s Manual and Important Safety Information Model: OC-SW121080 / OC-SW121160 / OC-SW121210 FEATURES

More information

Manual. EN Appendix. Blue Smart IP65 Charger 120V 12/7 12/10 12/15 24/8

Manual. EN Appendix. Blue Smart IP65 Charger 120V 12/7 12/10 12/15 24/8 Manual EN Appendix Blue Smart IP65 Charger 120V 12/7 12/10 12/15 24/8 IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for Blue

More information

BatteryMINDer 1500* & BatteryMINDer Plus 1510*

BatteryMINDer 1500* & BatteryMINDer Plus 1510* BatteryMINDer 1500* & BatteryMINDer Plus 1510* both with SmarTECHnology 12 Volt 1500 ma Charger - Maintainer - Desulfator INCLUDES: Auto-Temp Compensation Sensor, installed (1500 & 1510) Optional Permanent

More information

12 Volt 1500 ma Convertible Charger - Maintainer - Desulfator*

12 Volt 1500 ma Convertible Charger - Maintainer - Desulfator* 1215C 12 Volt 1500 ma Convertible Charger - Maintainer - Desulfator* INCLUDES: Auto-Temp Compensation Sensor, installed Optional Permanent Mounting Brackets and screws Battery Clips (Fully-Insulated 6

More information

Power Conversion. Battery Chargers. Model

Power Conversion. Battery Chargers. Model Power Conversion www.curtisinstruments.com 1 The Curtis high frequency battery chargers are portable and allow easy charging of industrial vehicle batteries from 24 VDC to 48 VDC using any standard outlet

More information

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY SMT WITH MPPT TECHNOLOGY Installation and Operation Manual Model:SMT SMT Dimensions Specification Summary System Voltage 12 V/24V Rated Battery Current 12V, 5A 8A 10A 15A 20A 25A 24V, 5A 8A 10A 15A Rated

More information

Eclipse Solar Suitcase

Eclipse Solar Suitcase Eclipse Solar Suitcase Renogy 100W 200W 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.0 Important Safety Instructions Please save these instructions. This manual contains important

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

Digital Intelligent Battery Charger OPERARATOR S MANUAL

Digital Intelligent Battery Charger OPERARATOR S MANUAL Digital Intelligent Battery Charger OPERARATOR S MANUAL WARNING! Before you install and use your Nitro Battery Charger, be sure to read and save these safety instructions. INTRODUCTION The Sinergex Nitro

More information

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions 335 E Warner Rd. STE 3 Chandler, AZ 85225 www.elitepowersolutions.com ABC Operation Manual Page 1 Table of Contents

More information

FlexCharger Battery Chargers

FlexCharger Battery Chargers FlexCharger Battery Chargers Operating Instructions Definitions (as used in these instructions) Flooded Battery Lead-acid battery with liquid electrolyte that requires open-venting and regular water replacement.

More information

SPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER

SPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, Email: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS - 2403SRM10 24V 0.5A MEDICAL

More information

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual CBC-9130 / 9215 12V 30A / 24V 15A Pro. Charger Operation manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct

More information

BATTERY CHARGER Plus Battery maintainer & Rejuvenator

BATTERY CHARGER Plus Battery maintainer & Rejuvenator BATTERY CHARGER Plus Battery maintainer & Rejuvenator For lead-acid batteries \\ Model No: 60132 1 WARNING The charger is designed to charge and maintain 12 Volt batteries only. (VRLA), AGM, Calcium, Gel

More information

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function. User Manual Design Features: 1. PFC function. except BC-1215HT / BC-2407HT 2. LCD remote control. BC-1215HT / BC-2407HT 3. Battery temperature sensor function. 4. Tri-LED color indicator for different

More information

Mobility. Energy. Anytime. Anywhere.

Mobility. Energy. Anytime. Anywhere. Mobility Energy. Anytime. Anywhere. INDEX Introduction 3 The Impulse II charger 4 Impulse II mobility charger 6 About Victron Energy 7 2 Energy. Anytime. Anywhere. Introduction Mobility and independence

More information

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell UPS 12-1121 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per APPLICATIONS Data Centers Network Operations Centers Industrial Process Control

More information

SBC / 2140 / Stage Battery Charger User Manual

SBC / 2140 / Stage Battery Charger User Manual SBC - 2130 / 2140 / 2150 3 Stage Battery Charger User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

Power Conversion. Battery Chargers. Model

Power Conversion. Battery Chargers. Model Power Conversion Model 1624 www.curtisinstruments.com 1 The Curtis Model 1624 is a high-frequency battery charger that is ideal for use in material handling, airport, golf, aerial lift, sweeper/scrubber,

More information

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500 INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE P/No.s IC700, IC700W, IC1000, IC1500 IMPORTANT SAFETY INFORMATION Please read this manual thoroughly before use and store in a safe place for future

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

2012 Battery Chargers Program

2012 Battery Chargers Program 2012 Battery Chargers Program www.bs-battery.com SPECIFICATIONS P/No. BA 10 BS 20 BS 40 BS 80 BS 160 BS 210 BK 10 Type: Automatic Smart Pro-Smart Bank Input Range: 100-240 Vac 100-240 Vac 100-240 Vac 100-240

More information

Solar Controller / Battery Charger User s Manual

Solar Controller / Battery Charger User s Manual Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

SPECIFICATIONS SR

SPECIFICATIONS SR 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8 e-mail: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS - 4812SR Totally Automatic

More information

Solar Charge Controller

Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Type Battery Type Code SC-600W MPPT Bulk Voltage Floating Voltage Vented 01 28.6 V 26.4 V Sealed 02 28.6 V 26.8 V Gel 03 28.6 V 27.4 V NiCd 04 28.6

More information

INSTRUCTION MANUAL CAUTION

INSTRUCTION MANUAL CAUTION FILE: IM_091-128-12E-40-115 Rev B., 2-16-2006 INSTRUCTION MANUAL AUTO CHARGE ODY q AUTOMATIC BATTERY CHARGER MODEL #091-128-12E-40-115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the

More information

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES. IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES. SPECIFICATIONS: For technical assistance, call your Dealer with the

More information

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4) Important: Please ensure that you read and save this instruction manual before using this product. Incorrect operation or misuse of this Battery Booster Pack may damage the equipment or create hazardous

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

Specification of Soneil Battery Charger

Specification of Soneil Battery Charger SONEIL INTERNATIONAL LIMITED 6033 Shawson Dr., Unit 29, Mississauga, Ontario, Canada L5T 1H8 Ph.: (905) 565-0360 Fax: (905) 565-0352 http://www.soneil.com Revision No.: R01 06/13/2008 Specification of

More information

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability Replace nearly any charger without

More information

INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE

INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE P/No.s IC700, IC700W, IC1000, IC1500 IMPORTANT SAFETY INFORMATION Please read this manual thoroughly before use and store in a safe place for

More information

Duo Battery Charge Controller

Duo Battery Charge Controller Duo Battery Charge Controller RENOGY 10A 20A Pulse Width Modulation Solar Charge Controller Manual 1 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 Version: 1.2 Important Safety Instructions

More information

Acura NSX 2016 Honda Motor Co., Ltd All rights reserved. BAM

Acura NSX 2016 Honda Motor Co., Ltd All rights reserved. BAM Acura NSX 2016 Honda Motor Co., Ltd All rights reserved. BAM03342-07 12V BATTERY CHARGER USER S INFORMATION MANUAL Introduction Thank you for purchasing this Acura accessory. This User s Information Manual

More information

PHOTO VOLTAIC CHARGE MODULE MULTI POINT TRACKING

PHOTO VOLTAIC CHARGE MODULE MULTI POINT TRACKING FEATURES Multi Point Tracking (MPT)/ Pulse Width Modulation (PWM) is a six stage solar charge controller. Drop-in PWM replacement for the PVCM-25D two stage solar charge controller. Works with the PVDM4-LC,

More information

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER The Intronics Power Inc. MPPT75HV Solar Charge Controller continually tracks the maximum power point of the solar panel array, adjusting

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current

More information

CX Series User s Manual

CX Series User s Manual CX Series User s Manual Advanced Converter / Charger Legal Provisions Copyrights 2016 COTEK Electronic IND. CO. All Rights Reserved. Any part of this document may not be reproduced in any form for any

More information

SPECIFICATIONS SR CHARGER

SPECIFICATIONS SR CHARGER 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, Email: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at http://soneil.com SPECIFICATIONS - 1212SR CHARGER Totally

More information

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries 15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries MB-3622 READ THESE INSTRUCTIONS BEFORE USE AND RETAIN FOR FUTURE REFERENCE! 1 CAUTION! When working

More information

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit) Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION Warranty Service

More information

SCCP PWM Charge Controller/Load Manager Owner s Manual

SCCP PWM Charge Controller/Load Manager Owner s Manual SCCP05-050 PWM Charge Controller/Load Manager Owner s Manual NOTE: Follow instructions in order. Charge batteries at least once a week. Use reducers to connect larger wires disconnect to terminals. battery

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

Intelligent Charging System Series

Intelligent Charging System Series R Intelligent Charging System Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models Amperage No. Of Banks Volts 16061 s 1 Bank 12 16102 6,s 2 Banks 12 or 24 16153 6,6,s 3 Banks 12 or 24 or 36 16202 10,10

More information

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array. EN Appendix Manual IMPORTANT Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array. Use for 24V battery system only 24V (72 cells) solar panel array. BlueSolar

More information

WF-5110R True Sine Wave Inverter

WF-5110R True Sine Wave Inverter Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION

More information

CBI All in One DC UPS Power Solutions

CBI All in One DC UPS Power Solutions CBI All in One Power Solutions Everything and more! More efficiency of the battery thanks to continuous control over time. More monitoring in main connection nodes: input, output load, battery. Event logging:

More information

Harness the Power of the Sun

Harness the Power of the Sun Harness the Power of the Sun Solar Controller / Battery Charger User s Manual Nominal Voltage: 12Volts Rated Solar Current: 30Amps / 40Amps Nominal Voltage: 12Volts / 24Volts Auto Rated Solar Current:

More information

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazard(s) of various risk levels or to important

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR!

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR! CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR! For your personal safety read, understand and follow the information provided in this instruction manual and on the solar regulator. 1

More information

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION Introduction Congratulations and thank you for purchasing Marlec s HRDi Charge Regulator. This is the latest technology for charge regulation of

More information

Clamps. Eyelets M8. Temperature sensor female connector. Battery cable female connector - 2

Clamps. Eyelets M8. Temperature sensor female connector. Battery cable female connector - 2 MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions. MPPT Solar System Controller ISC3040 Installation and Operating Instructions MPPT Solar System Controller ISC3040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s

More information

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers Sail Away with Peace of Mind Dolphin Series II Smart Battery Chargers DOLPHIN II SMART BATTERY CHARGERS OVERVIEW Small Power Chargers (small frame housing) Featuring two selectable outputs for charging

More information

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Guardian Battery Charger Series. Installation and Operations Manual Section 75 Guardian Battery Charger Series Installation and Operations Manual 00-02-0615 02-29-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

WF-5110R True Sine Wave Inverter

WF-5110R True Sine Wave Inverter Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION

More information

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual RNG Group Inc. (Renogy) 14288 Central Ave., Suite A Chino, CA 91710 1-800-330-8678 Product Description The Renogy Solar Suitcases combine

More information

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer 12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer For lead-acid batteries THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR 12V BATTERY CHARGER: YUA1201000 / INT1201000 KEEP

More information

Super PWRgate PG40S Spring City Drive Waukesha, WI

Super PWRgate PG40S Spring City Drive Waukesha, WI Super PWRgate PG40S www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2015, All rights reserved. All trademarks are the property of their respective

More information

EASY CHARGE Waterproof portable Battery Charger

EASY CHARGE Waterproof portable Battery Charger EASY CHARGE Waterproof portable Battery Charger 1.1 AND 4.3 AMP MODELS EN NL, DE, FR, ES, IT USER S MANUAL WWW.MASTERVOLT.COM/EASYCHARGE-PORTABLE 10000009117/04 2 EN / EasyCharge 1.1 and 4.3 Amp - User

More information