1 123 CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL 5.1 INTRODUCTION Wind energy generation has attracted much interest during the last few years. Large wind farms have been planned and installed in various locations around the world. Many of these wind farms are based on the Doubly Fed Induction Generator (DFIG) technology with converter ratings around 30 percent of the generator ratings. DFIG have more advantages over synchronous and induction generators when used in wind farms, such as robustness, reliability, low price, variable speed operation, active and reactive power control, relatively high efficiency, and lower converter cost. DPC technique based on grid voltage orientation has been proposed in this chapter. The DPC gets the same control performances as vector control, but has better robustness and simple structure. This DPC approaches the Instantaneous Reactive Power (IRP) p-q theory, which is based on the Clarke transform of voltages and currents in three-phase systems into α and β orthogonal coordinates. In this proposed control, DPC is used to control both active power and reactive power under steady state condition. Simulation is accomplished using MATLAB/Simulink software. The simulations are verified with laboratory hardware setup.

2 OPERATION OF DFIG A three-phase wound-rotor induction machine can be setup as a doubly-fed induction motor. In this case, the machine operates like asynchronous motor whose synchronous speed can be varied by adjusting the frequency of the ac currents fed into the rotor windings. The same woundrotor induction machine setup can also serve as a doubly-fed induction generator. In this case, mechanical power at the machine shaft is converted into electrical power supplied to the ac power network via both the stator and rotor windings. Furthermore, the machine operates like a synchronous generator whose synchronous speed (speed at which the generator shaft must rotate to generate power at the AC power network frequency) can be varied by adjusting the frequency of the AC currents fed into the rotor windings. In a conventional three-phase synchronous generator, when an external source of mechanical power (prime mover) makes the rotor of the generator rotate, the static magnetic field created by the DC current fed into the generator rotor winding rotates at the same speed as the rotor. As a result, a continually changing magnetic flux passes through the stator windings as the rotor magnetic field rotates, inducing an alternating voltage across the stator windings. Mechanical power applied to the generator shaft by the prime mover is thus converted to electrical power that is available at the stator windings. In conventional (singly-fed) induction generators, the relationship between the frequency of the ac voltages induced across the stator windings of the generator and the rotor speed is expressed using the Equation (5.1). - Frequency of the ac voltages induced across the stator windings

3 125 Speed of rotor in rps Number of poles in the DFIG per phase From the above Equation (5.1), it is very clear that, when the speed of the generator rotor is equal to the generator synchronous speed, the frequency of the AC voltages induced across the stator windings of the generator is equal to the frequency of the ac power network. The same operating principles apply in a doubly-fed induction generator as in a conventional (singly-fed) induction generator. The only difference is that the magnetic field created in the rotor is not static (not static means, it is created using three-phase AC current instead of DC current), but rather rotates at a speed proportional to the frequency of the AC currents fed into the generator rotor windings. This means that the rotating magnetic field passing through the generator stator windings not only rotates due to the rotation of the generator rotor, but also due to the rotational effect produced by the AC currents fed into the generator rotor windings. Therefore, in a DFIG both the rotation speed of the rotor and the frequency of the AC currents fed into the rotor windings determine the speed of the rotating magnetic field passing through the stator windings, and thus, the frequency of the alternating voltage is induced across the stator windings. Taking into account the principles of operation of doubly-fed induction generators, it can thus be determined that, when the magnetic field at the rotor rotates in the same direction as the generator rotor, the rotor speed and the speed of the rotor magnetic field add up. The frequency of the voltages induced across the stator windings of the generator can thus be calculated using the Equation (5.2).

4 126 - Frequency of rotor current fed into the rotor of DFIG Conversely, when the magnetic field at the rotor rotates in the direction opposite to that of the generator rotor, the rotor speed and the speed of the rotor magnetic field are subtracted from each other. The frequency of the voltages induced across the stator windings of the generator can thus be calculated using the Equation (5.3) DFIG Generate Fixed Frequency Voltages In other words, the frequency of the AC voltages produced at the stator of a DFIG is proportional to the speed of the rotating magnetic field at the stator. The speed of the stator rotating magnetic field itself depends on the rotor speed (resulting from the mechanical power at the rotor shaft) and the frequency of the AC currents fed into the machine rotor. When a DFIG is used to produce power at the AC power network voltage and frequency, any deviation of the generator rotor speed from the synchronous speed is compensated by adjusting the frequency of the AC currents fed into the generator rotor windings so that the frequency of the voltage produced at the stator remains equal to the AC power network frequency. In other words, the frequency is adjusted so that the speed of the rotating magnetic field passing through the stator windings remains constant. Consequently, to maintain the voltage produced at the stator equal to the AC power network voltage, a specific magnetic flux value must be maintained in the machine.

5 127 This can be achieved by applying a voltage to the generator rotor windings that is proportional to the frequency of the voltages applied to the rotor windings (it maintains the V/f ratio constant and ensures a constant magnetic flux value in the machine). The value of the V/f ratio is generally set; so that the reactive power at the stator is equal to zero. This is similar to the common practice used with conventional (singly-fed) synchronous generators where the exciter current is adjusted so as to zero the reactive power at the stator Advantages of Using DFIG for Wind Power Applications Using a DFIG instead of an asynchronous offers the generator in wind turbines following advantages: 1. Operation at variable rotor speed while the amplitude and frequency of the generated voltages remain constant. 2. Optimization of the amount of power generated as a function of the wind available up to the nominal output power of the wind turbine generator. 3. Virtual elimination of sudden variations in the rotor torque and generator output power. 4. Generation of electrical power at lower wind speeds. 5. Control of the power factor. On the other hand, the DFIG requires complex power conversion circuitry which the asynchronous generator does not need. Also, the slip rings on the wound-rotor induction machine used to implement the DFIG require periodic maintenance while no such rings are required on the rotor of the

6 128 squirrel-cage induction machine used to implement the asynchronous generator. Use of synchronous generator in wind turbines offers the same advantages as when a DFIG is used. Both types of generator require two AC/DC converters. However, the two AC/DC converters in DFIG are significantly smaller than those in synchronous generators of comparable output power. This is because the AC/DC converters in DFIG convey only about 30% of the nominal generator output power while the AC/DC converters in synchronous generators convey 100% of the nominal generator output power DFIG for Variable Speed Application DFIG s come into play for wind power conversion, as they allow the generator output voltage and frequency to be maintained at constant values. This is achieved by feeding ac currents of variable frequency and amplitude into the generator rotor windings. Iwanski & Koczara (2008) addressed, by adjusting the amplitude and frequency of the AC currents fed into the generator rotor windings, it is possible to keep the amplitude and frequency of the voltages (at stator) produced by the generator constant, despite variations in the wind turbine rotor speed caused by fluctuations in wind speed By doing so, this also allows operation without sudden torque variations at the wind turbine rotor, thereby decreasing the stress imposed on the mechanical components of the wind turbine and smoothing variations in the amount of electrical power produced by the generator. Using the same means, it is also possible to adjust the amount of reactive power exchanged between the generator and the AC power network. This allows the power factor of the system to be controlled. Finally, a doubly-fed induction

7 129 generator in variable-speed wind turbines allows electrical power generation at lower wind speeds than with fixed-speed wind turbines using an asynchronous generator. 5.3 DFIG MODEL The DFIG has two sets of three-phase windings that display self and mutual inductances. Mutual inductances change as the machine turns and the angle between stator and rotor circuits varies with time, which ultimately leads to a time-varying mathematical model of the machine. This angle dependency in DFIG s model and the associated complexities can be surmounted by making a transformation from three-phase magnitudes to twoaxis magnitudes (Clark s transformation) and transforming the magnitudes into direct and quadrature components referred to a synchronously rotating reference frame (Park s transformation). The DFIG model in the synchronous reference frame can be expressed as Equations (5.4) to (5.12), where the model corresponds to the angular speed of the rotating reference frame.

8 130 ( ) Mathematical Representation of DFIG Ganti et al (2012) addressed the mathematical model, which is similar to the squirrel cage induction machine; the only difference is that the rotor voltage is non-zero in DFIG. In order to simulate the Wind Energy Conversion System a proven method is needed to represent the characteristics of DFIG. The rest of this section is devoted to the mathematical equations that describe a DFIG. The voltage equations to represent a 3-phase induction machine can be expressed by, [ ] [ ][ ] [ ] [ ] [ ][ ] [ ] [ ] [ ] Where ν, r, i, and ψ respectively refer to the voltage, resistance, current, and flux linkage of the phase windings. The subscripts a, b, and c refer to their phase component. The subscripts r and s refer to the stator and rotor windings. The term ρ represents the derivative (d/dt). The flux linkages shown in Figure 5.1 for a linear magnetically coupled circuit are expressed as Equation (5.17) to (5.20).

9 131 Figure 5.1 Equivalent circuit of induction machine in d-q reference frame Where and are rotor and stator voltages and are rotor and stator fluxes, are rotor and stator resistance & inductance. = Mutual inductance are Rotor & Synchronous angular speed In rotating reference frame the machine model is,

10 132 The mechanical part of the model is, The active and reactive powers inputs from the network can be calculated as, [ ]

11 133 [ ] 5.4 BASIC CONFIGURATION Figure 5.2 shows the basic configuration of DFIG. Based on the operation such as sub synchronous, synchronous and super synchronous speed of the DFIG, the power flow is from rotor to grid or grid to rotor. The total power supplied to grid is sum of the power from stator and rotor power. Figure 5.2 Basic configuration of DFIG wind turbine DFIG supplied the power to grid from its stator when P s > 0. Rotor received the power from grid when r< s, it means that P r < 0. Rotor also supplied power to grid when P r > s, it means that P r > 0. Here r, s, P r, P s are rotor speed, stator speed, power from rotor and power from stator respectively. Hence by operating the DFIG in sub synchronous, synchronous and super synchronous modes and the outputs in terms of rotor powers are Pr < 0, Pr = 0 and Pr > 0 respectively. 5.5 CONTROL METHODS Different control methods are popular in the industry, such as scalar method (V/f), vector control, direct and indirect field oriented control,

12 134 rotor and stator flux control, adaptive flux observer, stator flux orientation and field weakening control. All the said methods are complex, for reducing the complexity to choose the direct power control scheme to control the machine. The DFIG control level performs the control of the rotor side and the grid-side back-to-back converters. A vector control approach is adopted for the rotor controller, while two cross coupled controllers adjust the speed and power of the system. The goals of such controllers are to track the optimum operation point, limit the power in the case of high wind speeds, and control the reactive power exchanged between the wind turbine generator and the grid. The control of the grid-side converter keeps a constant DC-link voltage while injecting the active power to the grid. Internal current loops in both converters are typically using proportional integral (PI) controllers. DTC and DPC schemes have been presented as alternative methods which directly control machine flux and torque via the selection of suitable voltage vectors. It has been shown that DPC is a more efficient approach compared to modified DTC. However, the DPC method also depends on the estimation of machine parameters and it requires a protection mechanism to avoid over current during a fault in the system. In induction wind generators, unbalanced three phase stator voltages cause a number of problems, including overheating and stress on the mechanical components from torque pulsations. Therefore, beyond a certain amount of imbalance (6%), induction wind generators are switched out of the network. In DFIG control of rotor currents allows for adjustable speed operation and reactive power control. In addition, it is possible to control the rotor currents to correct the problems caused by unbalanced stator voltages. This research presents a new controller design for a doubly-fed induction generator that provides adjustable speed and reactive power control while greatly reducing torque pulsations.

13 Rotor Side Converter The RSC supplies the voltage to the rotor windings of the DFIG. The purpose of the rotor-side converter is to control the rotor currents such that the rotor flux position is optimally oriented with respect to the stator flux in order that the desired torque is developed has been studied by Jiabing Hu et al (2011). The rotor-side converter uses a torque controller to regulate the wind turbine output power and the voltage (or reactive power) measured at the machine stator terminals. The power is controlled in order to follow a pre-defined turbine power-speed characteristic to track the maximum power point. The actual electrical output power from the generator terminals, added to the total power losses (mechanical and electrical) is compared with the reference power obtained from the wind turbine characteristic. Usually, a Proportional-Integral (PI) regulator is used at the outer control loop to reduce the power error (or rotor speed error) to zero. The output of this regulator is the reference rotor current i rqref that must be injected in the rotor winding by rotor-side converter. This q-axis component controls the electromagnetic torque Te. The actual i rq component of rotor current is compared with i rqref and the error is reduced to zero by a current PI regulator at the inner control loop. Figure 5.3 shows the rotor side converter control scheme. The output of this current controller is the voltage v rq generated by the rotor-side converter. With another similarly regulated i rd and v rd component the required 3-phase voltages applied to the rotor winding are obtained.

14 136 Figure 5.3 Rotor side converter control scheme Control of Real and Reactive Power Using the RSC The grid side converter is used to partly control the flow of real and reactive power from the turbine system to the grid. The grid-side converter feeds the grid through a set of interfacing inductors. The grid-side converter (a voltage source inverter) can generate a balanced set of threephase voltages at the supply frequency and that the voltage (E) can have a controllable magnitude and phase. Load angle control is used to illustrate the basics of real and reactive power control, though in practise, a more sophisticated control is used which provides superior transient response. Essentially, load angle control uses the angle ( ) between the voltage generated by the grid-side converter (E) and the grid voltage (V). The steady-

15 137 state equations relate to the real and reactive power flow from the grid-side converter to the grid are shown in Equation (5.35) and (5.36). Showing that P can be controlled using load angle δ l, and Q can be controlled using the magnitude of E. The combination of control and power electronics enables the grid-side converter to produce the necessary voltage magnitude (E) and load angle (δ l), in order to meet a required P s and Q s demand set by the main system controller. The controller should be able to synchronise the grid frequency and phase, in order to connect and supply power. At any instance, the power exported by the GSC is determined by the state of the DC- link voltage. The grid-side converter controller monitors the DC- link voltage. If the DC- link voltage rises, the grid-side converter can export more real power by increasing the load angle in order that the DC- link voltage moves back towards it nominal value. If more power is being exported by the GSC than is currently being generated by the RSC, the DC link voltage will fall below its nominal value has been dealt by Jiabing Hu et al (2013). The grid-side controller will then reduce the exported real power to allow the DC link voltage to recover to its nominal value. In this sense, the DC link voltage indicates power flow balance between the generated energy and the exported energy in the rotor side. If the input and output power to the DC link capacitor do not match, then the DC link voltage will change. The quality of the energy supplied to the network must meet basic requirements and it will be set by the grid code in force at the PCC.

16 138 The grid code specifies many performance indicators of the quality of the energy supplied by the grid-side converter, along with other important issues such as fault level. The relevant grid code(s) in operation must be determined prior to tendering for work on the turbine power electronics and control. The grid code has important implications on the control system of the turbine. If the generator-side controller continues to generate power, the DC link capacitance will be over charged. Therefore, a grid fault will require the generator to stop generating energy, which then means that there is no longer a restraining torque to control the blade speed. In a wind turbine, a loss of supply will cause an over speed condition, as the blade system will accelerate due to the aerodynamic torque produced by the blades. Shorting resistors, or a crowbar circuit, is often switched across the rotor circuit of the generator in order that the energy generated by the blade system can be absorbed and the high speed condition controlled to a safe and manageable level. In addition, there are often aerodynamic (pitch control) and mechanical braking mechanisms included in wind turbines as an additional over-speed safety measure Grid Side Converter Different control strategies are used to perform the control of the grid side converter. They all are focused on the same topics, the control of the DC-link voltage, active and reactive power delivered to the grid, grid synchronization and to ensure high quality of the injected power.they can be classified depending on the reference frame used in the control structure. In this research, the focus is on the synchronous and stationary reference frame control strategies. In both cases, the control strategy contains two cascaded loops. Figure 5.4 shows the grid side converter control scheme.

17 139 The inner loops control the grid currents and the outer loops control the DC-link voltage and the reactive power. The current loops are responsible for the power quality, thus harmonic compensation can be added to the action of the current controllers to improve it. The outer loops regulate the power flow of the system by controlling the active and reactive power delivered to the grid. The total current delivered into the grid is the sum of the currents from stator side and grid side. Since the negative-sequence current of the DFIG stator is eliminated with the effective control of GSC has been described by Jun Yao et al (2008). Figure 5.4 Grid side converter control scheme Direct Power Control The DPC inherits most of its theoretical background from the DTC. DPC also exploits the geometrical relationship between stator and rotor fluxes and the fact that the rotor flux can be fully controlled through the RSC.

18 140 This distinction change in the control approach has a significant impact on the robustness and simplicity of the DPC strategy, whose main features include: 1) Independence from machine parameters 2) Reduced number of electrical magnitudes to be measured and 3) No need for reference frame transformations P Q Controller Operation Once the voltage is induced in the stator, it is compared with the grid voltage at the other side of the coupling reactance and the stator current is calculated. Starting from the value of the stator voltages and currents, the actual active P and reactive Q powers interchanged with the grid are calculated. These powers are compared with their respective references, P* and Q*, so that a regulator can correct the error in the next calculation to be performed on the voltages needed to be induced in the stator. Once the machine is connected to the grid, the system may be operated in two different modes in order to set the commands for the active and reactive powers. Manual mode setting of P and Q references is one method and the other one is the activation of the maximum power point tracking operating mode. The second case, the quaintest essential is to operate the generator with zero reactive power reference. 5.6 SIMULATION RESULT Simulations of the proposed control strategy for a DFIG based wind power generation system were carried out, using MATLAB/Simulink. Discrete models were used with a simulation time step of 1.5s. The DFIG is rated at 1.3 kw. Choose the DC link capacitor as 1200µF, 600V. The nominal

19 141 converter DC- link voltage was set at 300V. The grid side converter has to maintain a constant DC-link voltage, and it is controlled by a method similar to the DC voltage controller in a PWM voltage source rectifier. During simulations, a sampling frequency of 10 khz was used for the proposed control strategy. A high-frequency ac filter is connected to the stator side to absorb the switching harmonics generated by the two converters. Figure 5.5 Simulink diagram of back to back converter with DFIG Figure 5.5 shows the SIMULINK modelling of back to back converter with DFIG. The filter is a single-tuned one with inductance and resistance connected in parallel instead of series, which results in a wide band filter having impedance at high frequencies limited by the resistance. In a practical system, voltages and currents are sampled at the beginning of each sampling period. The required rotor control voltage for the sampling period is

20 142 then calculated and passed to the SVM (Support Vector Machine) module. Impossible to avoid, there is a time delay between the instant sampling and SVM modulator s receiving the required rotor control voltage and updating its register values. Figure 5.6 Grid side converter phase volt and current for a sub synchronous speed (135 rad/s) Rotor voltage calculation of the proposed DPC strategy is relatively simple, and the time delay should be adroit small. In spite of that, the calculated output rotor voltage is delayed by 4 ms (one sampling period) to closely represent a practical DPC control system. During the simulation, the grid side converter is enabled first, so that the converter DC-link voltage is regulated. The generator is then excited by rotor-side converter with the rotor rotating at a fixed speed till the stator voltage matches with the network voltage, such that the DFIG system is switched into grid-connected operation.

21 143 Figure 5.7 Grid side converter phase volt and current for synchronous speed (157 rad/s) Figure 5.8 Grid side converter phase volt and current for super synchronous speed (179 rad/s)

22 144 Figure 5.9 Rotor side converter phase voltage and current for sub synchronous speed (135 rad/sec) The Figures 5.6 to 5.8 shows the grid side converter phase volt and current for a sub synchronous, synchronous and super synchronous speed. respectively. Figure 5.10 Rotor side converter phase voltage and current for synchronous speed (157 rad/sec)

23 145 Figure 5.11 Rotor side converter phase voltage and current for super synchronous speed (179 rad/sec) The Figures 5.9 to 5.11 shows the rotor side converter phase volt and current for a sub synchronous, synchronous and super synchronous speed respectively. The Figure 5.12 to 5.14 shows the stator phase volt and current for a sub synchronous, synchronous and super synchronous speed respectively. Figure 5.12 Stator phase volt and current for sub synchronous speed (135 rad/sec)

24 146 Figure 5.13 Stator phase volt and current for synchronous speed (157 rad/sec) Figure 5.14 Stator phase volt and current for super synchronous speed (179 rad/sec) Figure 5.15 to 5.17 shows the constant reactive power for a sub synchronous, synchronous and super synchronous speed respectively.

25 147 Figure 5.15 Constant reactive power with variable active power for sub synchronous speed (135 rad/sec) Figure 5.16 Constant reactive power with variable active power for synchronous speed (157 rad/sec)

26 148 Figure 5.17 Constant reactive power with variable active power for super synchronous speed (179 rad/sec) 5.7 DESCRIPTION OF THE EXPERIMENTAL WORK-BENCH As it can be seen in the picture shown in Figure 5.18, the bench is composed of two controlled electrical drives: one is the wind turbine emulator (DC motor) and the other is the electric generator (DFIG), coupled on the same shaft. The wind turbine emulator (WTE) consists of a DC motor driven by a Siemens AC/ DC converter that can be easily configurable. Figure 5.19 shows a proposed grid connected DFIG with all supporting components like GSC, RSC, measuring units (Power quality analyser) and FPGA - controller. The specific components used in the presented proposed grid connected DFIG are: A 1.3 kw, 220 V, 1500 rpm, DC shunt machine. It is mechanically coupled to the generator to transmit the desired torque.

27 149 Figure 5.18 DFIG and DC motor coupled on the same shaft Figure.5.19 Experimental test rig of DFIG An AC/DC Siemens converter for DC drives. It supplies the suitable voltage or current to the DC machine in order to achieve the specified torque reference. A 1.3 kw, 1410 rpm, 4 poles, 415 V wound rotor asynchronous machine an AC/DC, 1200 V, 25 A three-phase controlled IGBT converter. When working below the synchronous speed, it rectifies the

28 150 voltage or currents from the grid to feed the DC bus from which the generator converter will feed the wind generator rotor. Above that speed, it will control the DC bus voltage delivering power to the grid. At all times, the control system of this converter regulates the reactive power exchanged with the grid to which the generator s rotor is connected. A DC/AC 1200 V, 25 A, three-phase controlled IGBT s converter feeds the DFIG s rotor with AC obtaining the energy from the DC bus. The control system calculates how the rotor phases must be fed so that the generator s stator delivers the maximum electric power associated to different wind conditions to the grid. The control system also regulates the reactive power exchanged with the grid through the generator s stator by means of this converter. A FPGA - Spartan 6 based control system composed development board has been used as controller. This hardware allows for the simultaneous controlling of the IGBT firing signals in the DC/AC generator side converter and those of the AC/DC grid side converter. The interface included with this system allows for the real-time tracking of the change of any variable in the entire generation system. A Hall Effect sensors box for adapting voltage and current measurements to the FPGA input channels System Operation The described system is designed to be operated in the following manner 1. The DC machine coupled with DFIG act as wind turbine emulator and is initiated using a specific wind reference. The wind turbine emulator control system (Siemens control) reads the turbine speed from the generator control system (FPGA).

29 When the generator control system detects the minimum speed at which the DFIG must be started, both the grid converter and the generator converter are started in order to prepare the system for connection to the grid. 3. Once the DFIG stator generates three voltages equal to those of the grid to which it will be connected, the grid connection switch is closed. 4. When the generator stator is connected to the grid, the generator control system can operates the specified active and reactive power (zero). 5. At the same time, the grid converter control system maintains the DC bus voltage equivalent to the reference value. 6. From this point, the system works automatically and the only parameter that can be modified is the DC machine current or torque reference. 7. At any turbine speed, the DFIG will deliver the maximum active power established by a reference table, including the higher speed values at which the pitch angle must be changed. The generator control system operates to maintain zero reactive power interchanged with the grid. 8. According to the grid converter control system, it is important to remember that when the wind turbine operates below the synchronous speed, this converter (GSC) acts as a rectifier, allowing the energy to flow from the grid to the rotor. But when the turbine speed increases above the synchronous value, it works as an inverter, delivering power from the rotor to the grid. Moreover, this converter also collaborates in the global reactive power control.

30 Hardware Results To demonstrate the operating possibilities of this system, we present the results of a specific test consisting of the production of an increment of the wind speed while operating the system on manual reference mode. The test results are presented in Figures 5.20 and Figure 5.20 Stator voltage, stator current and rotor current for sub synchronous speed as 135 rad/sec The intention of this test is that the wind increases carries an increment of the machine rotating speed which increases from 1288 rpm, under synchronous speed 1500 rpm, to a super-synchronous speed 1702 rpm.

31 153 Figure 5.21 Stator voltage, stator current and rotor current for synchronous speed as 157 rad/sec Figure 5.22 Stator voltage, stator current and rotor current for super synchronous speed as 179 rad/sec

32 154 Figure 5.20 and 5.22 shows the evolution of the voltage amplitude, the frequency, and the three phase currents injected into the grid, as well as the value of the active (P) and reactive (Q) power interchanged with the grid through the stator for different rotor frequencies, whose values follow at all times the constant references established for this test. Figure 5.23 shows the rotor side converter voltage, which is 350 volts line to line. Figure 5.23 Stator voltage, stator current and rotor side converter line voltage for super synchronous speed as 179 rad/sec 5.8 SUMMARY The operation of DFIG was reviewed and the mathematical model for real and reactive powers are derived from its equivalent circuit. The control circuit for GSC and RSC have been prepared by using direct power control scheme and implemented. The simulation of a 1.3 kw DFIG based GCWECS with PI controller is carried out using MATLAB/SIMULINK. The

33 155 steady state behaviour of system was analysed for synchronous (157 rad/sec), sub synchronous (135 rad/sec) and super synchronous speed (179 rad/sec). The reactive power supplied by DFIG for three modes of operations (synchronous, sub synchronous and super synchronous speeds) is zero, and has been justified by the simulation results. The hardware results also confirmed the simulation results.

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,

More information

Principles of Doubly-Fed Induction Generators (DFIG)

Principles of Doubly-Fed Induction Generators (DFIG) Renewable Energy Principles of Doubly-Fed Induction Generators (DFIG) Courseware Sample 86376-F0 A RENEWABLE ENERGY PRINCIPLES OF DOUBLY-FED INDUCTION GENERATORS (DFIG) Courseware Sample by the staff

More information

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM 47 CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM 4.1 INTRODUCTION Wind energy has been the subject of much recent research and development. The only negative

More information

Doubly fed electric machine

Doubly fed electric machine Doubly fed electric machine Doubly fed electric machines are electric motors or electric generators that have windings on both stationary and rotating parts, where both windings transfer significant power

More information

INTRODUCTION. I.1 - Historical review.

INTRODUCTION. I.1 - Historical review. INTRODUCTION. I.1 - Historical review. The history of electrical motors goes back as far as 1820, when Hans Christian Oersted discovered the magnetic effect of an electric current. One year later, Michael

More information

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators Abstract: G. Thrisandhya M.Tech Student, (Electrical Power systems), Electrical and Electronics Department,

More information

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS) ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS) A wind energy conversion system (WECS) is composed of blades, an electric generator, a power electronic converter, and a control

More information

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 100 CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 6.1 INTRODUCTION Conventional energy resources are not sufficient to meet the increasing electrical power demand. The usages of

More information

Modelling and Simulation of DFIG with Fault Rid Through Protection

Modelling and Simulation of DFIG with Fault Rid Through Protection Australian Journal of Basic and Applied Sciences, 5(6): 858-862, 2011 ISSN 1991-8178 Modelling and Simulation of DFIG with Fault Rid Through Protection F. Gharedaghi, H. Jamali, M. Deisi, A. Khalili Dashtestan

More information

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011 EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Fall 2011 Overview Environmental pressures have led many countries to set ambitious goals of renewable energy generation. Wind energy is the dominant renewable

More information

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System Sugali Shankar Naik 1, R.Kiranmayi 2, M.Rathaiah 3 1P.G Student, Dept. of EEE, JNTUA College of Engineering, 2Professor,

More information

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS 88 CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS 5.1 INTRODUCTION The advances in power electronics technology have enabled the use of variable speed induction generators for wind energy

More information

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Wind Energy 101: See Video Link Below http://energy.gov/eere/videos/energy-101- wind-turbines-2014-update Wind Power Inland and Offshore Growth in Wind

More information

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM A THESIS Submitted in partial fulfilment of the requirements for the award of the degree of DOCTOR OF PHILOSOPHY

More information

Effect of crowbar resistance on fault ride through capability of doubly fed induction generator

Effect of crowbar resistance on fault ride through capability of doubly fed induction generator ISSN: 2347-3215 Volume 2 Number 1 (January, 2014) pp. 88-101 www.ijcrar.com Effect of crowbar resistance on fault ride through capability of doubly fed induction generator V.Vanitha* and K.Santhosh Amrita

More information

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT 2 nd International Conference on Energy Systems and Technologies 18 21 Feb. 2013, Cairo, Egypt ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT Mohamed Ebeed 1, Omar NourEldeen

More information

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator Buletin Teknik Elektro dan Informatika (Bulletin of Electrical Engineering and Informatics) Vol. 2, No. 4, December 2013, pp. 272~277 ISSN: 2089-3191 272 A Variable Speed Wind Generation System Based on

More information

Statcom Operation for Wind Power Generator with Improved Transient Stability

Statcom Operation for Wind Power Generator with Improved Transient Stability Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 4, Number 3 (2014), pp. 259-264 Research India Publications http://www.ripublication.com/aeee.htm Statcom Operation for Wind Power

More information

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION International Journal of Latest Research in Science and Technology Volume 3, Issue 1: Page No.68-74,January-February 2014 http://www.mnkjournals.com/ijlrst.htm ISSN (Online):2278-5299 POWER QUALITY IMPROVEMENT

More information

Asian Journal on Energy and Environment ISSN Available online at

Asian Journal on Energy and Environment ISSN Available online at As. J. Energy Env. 2005, 6(02), 125-132 Asian Journal on Energy and Environment ISSN 1513-4121 Available online at www.asian-energy-journal.info Dynamic Behaviour of a Doubly Fed Induction Machine with

More information

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios Trivent Publishing The Authors, 2016 Available online at http://trivent-publishing.eu/ Engineering and Industry Series Volume Power Systems, Energy Markets and Renewable Energy Sources in South-Eastern

More information

Inverter control of low speed Linear Induction Motors

Inverter control of low speed Linear Induction Motors Inverter control of low speed Linear Induction Motors Stephen Colyer, Jeff Proverbs, Alan Foster Force Engineering Ltd, Old Station Close, Shepshed, UK Tel: +44(0)1509 506 025 Fax: +44(0)1509 505 433 e-mail:

More information

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System Mrs. Aparimita Pati,

More information

Chapter 2 Literature Review

Chapter 2 Literature Review Chapter 2 Literature Review 2.1 Introduction Electrical power is the most widely used source of energy for our homes, workplaces, and industries. Population and industrial growth have led to significant

More information

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS Lucian Mihet-Popa "POLITEHNICA" University of Timisoara Blvd. V. Parvan nr.2, RO-300223Timisoara mihetz@yahoo.com Abstract.

More information

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 12, Issue 3 Ver. II (May June 2017), PP 124-129 www.iosrjournals.org Comparative Analysis

More information

Synchronous Motor Drives

Synchronous Motor Drives UNIT V SYNCHRONOUS MOTOR DRIVES 5.1 Introduction Synchronous motor is an AC motor which rotates at synchronous speed at all loads. Construction of the stator of synchronous motor is similar to the stator

More information

VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS

VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS Dhayalan A #1 and Mrs. Muthuselvi M *2 # PG Scholar, EEE, Velammal Engineering college, chennai,india * Assistant

More information

Possibilities of Distributed Generation Simulations Using by MATLAB

Possibilities of Distributed Generation Simulations Using by MATLAB Possibilities of Distributed Generation Simulations Using by MATLAB Martin Kanálik, František Lizák ABSTRACT Distributed sources such as wind generators are becoming very imported part of power system

More information

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR Velimir Nedic Thomas A. Lipo Wisconsin Power Electronic Research Center University of Wisconsin Madison

More information

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid Research Inventy: International Journal of Engineering And Science Vol.6, Issue 1 (January 2016), PP -17-24 Issn (e): 2278-4721, Issn (p):2319-6483, www.researchinventy.com Simulation Modeling and Control

More information

Performance Analysis of DFIG Based Wind Power Generation under Unbalanced Conditions

Performance Analysis of DFIG Based Wind Power Generation under Unbalanced Conditions Performance Analysis of DFIG Based Wind Power Generation under Unbalanced Conditions ANJU. M 1 R. RAJASEKARAN 2 1, Department of EEE, SNS College of Technology, Coimbatore. 2, Department of EEE, SNS College

More information

ELG4125: Flexible AC Transmission Systems (FACTS)

ELG4125: Flexible AC Transmission Systems (FACTS) ELG4125: Flexible AC Transmission Systems (FACTS) The philosophy of FACTS is to use power electronics for controlling power flow in a transmission network, thus allowing the transmission line to be loaded

More information

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

Study of DFIG based Wind Turbine for Reactive Power Generation Capability Study of DFIG based Wind Turbine for Reactive Power Generation Capability Janarthanan.S Assistant Professor, Department of EEE-M, AMET University, Chennai Abstract: In this paper to enhance the ability

More information

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM Ms. Dipali A. Umak 1, Ms. Trupti S. Thakare 2, Prof. R. K. Kirpane 3 1 Student (BE), Dept. of EE, DES s COET, Maharashtra,

More information

Modeling of doubly fed induction generator (DFIG) equipped wind turbine for dynamic studies

Modeling of doubly fed induction generator (DFIG) equipped wind turbine for dynamic studies Modeling of doubly fed induction generator (DFIG) equipped wind turbine for dynamic studies Mattia Marinelli, Andrea Morini, Andrea Pitto, Federico Silvestro Department of Electric Engineering, University

More information

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG C.Nikhitha 1, C.Prasanth Sai 2, Dr.M.Vijaya Kumar 3 1 PG Student, Department of EEE, JNTUCE Anantapur, Andhra Pradesh, India.

More information

Renewable Energy Systems 13

Renewable Energy Systems 13 Renewable Energy Systems 13 Buchla, Kissell, Floyd Chapter Outline Generators 13 Buchla, Kissell, Floyd 13-1 MAGNETISM AND ELECTROMAGNETISM 13-2 DC GENERATORS 13-3 AC SYNCHRONOUS GENERATORS 13-4 AC INDUCTION

More information

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE Richa jain 1, Tripti shahi 2, K.P.Singh 3 Department of Electrical Engineering, M.M.M. University of Technology, Gorakhpur, India 1 Department

More information

Overview of Flexible AC Transmission Systems

Overview of Flexible AC Transmission Systems Overview of Flexible AC Transmission Systems What is FACTS? Flexible AC Transmission System (FACTS): Alternating current transmission systems incorporating power electronic-based and other static controllers

More information

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load,,, ABSTRACT- In this paper the steady-state analysis of self excited induction generator is presented and a method to calculate

More information

CHAPTER 2 MODELLING OF SWITCHED RELUCTANCE MOTORS

CHAPTER 2 MODELLING OF SWITCHED RELUCTANCE MOTORS 9 CHAPTER 2 MODELLING OF SWITCHED RELUCTANCE MOTORS 2.1 INTRODUCTION The Switched Reluctance Motor (SRM) has a simple design with a rotor without windings and a stator with windings located at the poles.

More information

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop] Power Electronics & [Simulink, Hardware-Open & Closed Loop] Project code Project theme Application ISTPOW801 Estimation of Stator Resistance in Direct Torque Control Synchronous Motor ISTPOW802 Open-Loop

More information

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50

More information

Modeling Of DFIG and Improving the LVRT Capability Of System Using Crowbar And Battery Energy Storage System

Modeling Of DFIG and Improving the LVRT Capability Of System Using Crowbar And Battery Energy Storage System Modeling Of DFIG and Improving the LVRT Capability Of System Using Crowbar And Battery Energy Storage System 1 T. Santhiya, 2 S. Nithya 1 Assistant Professor, 2 Assistant Professor 1 Department of EEE,

More information

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 61 CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 3.1 INTRODUCTION The modeling of the real time system with STATCOM using MiPower simulation software is presented in this

More information

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim Dept. of Electrical Engineering Kwangwoon University, Korea Summary

More information

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 201

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP (  201 Study And Analysis Of Fixed Speed Induction Generator Based Wind Farm Grid Fault Control Using Static Compensator Abstract 1 Nazia Zameer, 2 Mohd Shahid 1 M.Tech(Power System) Scholar, Department of EEE,

More information

CONTROL OF DOUBLY FED INDUCTION GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

CONTROL OF DOUBLY FED INDUCTION GENERATOR BASED WIND ENERGY CONVERSION SYSTEM CONTROL OF DOUBLY FED INDUCTION GENERATOR BASED WIND ENERGY CONVERSION SYSTEM R.Rajeswari PG Student, Research Scholar, Dept. of Electrical and Electronics Engineering, College of Engineering Guindy, Anna

More information

Fault Rid Through Protection of DFIG Based Wind Generation System

Fault Rid Through Protection of DFIG Based Wind Generation System Research Journal of Applied Sciences, Engineering and Technology 4(5): 428-432, 212 ISSN: 24-7467 Maxwell Scientific Organization, 212 Submitted: September 14, 211 Accepted: October 15, 211 Published:

More information

Simulation of Indirect Field Oriented Control of Induction Machine in Hybrid Electrical Vehicle with MATLAB Simulink

Simulation of Indirect Field Oriented Control of Induction Machine in Hybrid Electrical Vehicle with MATLAB Simulink Simulation of Indirect Field Oriented Control of Induction Machine in Hybrid Electrical Vehicle with MATLAB Simulink Kohan Sal Lotf Abad S., Hew W. P. Department of Electrical Engineering, Faculty of Engineering,

More information

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK International Journal Of Engineering Research And Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 14, Issue 1 (January 2018), PP.59-63 Dynamic Behaviour of Asynchronous Generator

More information

Real-time Simulation of Electric Motors

Real-time Simulation of Electric Motors Real-time Simulation of Electric Motors SimuleD Developments in the electric drive-train have the highest priority, but all the same proven development methods are not consequently applied. For example

More information

Matlab Modeling and Simulation of Grid Connected Wind Power Generation Using Doubly Fed Induction Generator

Matlab Modeling and Simulation of Grid Connected Wind Power Generation Using Doubly Fed Induction Generator ISSN (e): 2250 3005 Vol, 04 Issue, 7 July 2014 International Journal of Computational Engineering Research (IJCER) Matlab Modeling and Simulation of Grid Connected Wind Power Generation Using Doubly Fed

More information

Grid Connected DFIG With Efficient Rotor Power Flow Control Under Sub & Super Synchronous Modes of Operation

Grid Connected DFIG With Efficient Rotor Power Flow Control Under Sub & Super Synchronous Modes of Operation Grid Connected DFIG With Efficient Power Flow Control Under Sub & Super Synchronous Modes of D.Srinivasa Rao EEE Department Gudlavalleru Engineering College, Gudlavalleru Andhra Pradesh, INDIA E-Mail:dsrinivasarao1993@yahoo.com

More information

Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique

Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique Australian Journal of Basic and Applied Sciences, 7(7): 370-375, 2013 ISSN 1991-8178 Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique 1 Mhmed M. Algrnaodi,

More information

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL 3.1 Introduction Almost every mechanical movement that we see around us is accomplished by an electric motor. Electric machines are a means of converting

More information

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M] Code No:RT32026 R13 SET - 1 III B. Tech II Semester Regular Examinations, April - 2016 POWER SEMICONDUCTOR DRIVES (Electrical and Electronics Engineering) Time: 3 hours Maximum Marks: 70 Note: 1. Question

More information

Wind Turbine Emulation Experiment

Wind Turbine Emulation Experiment Wind Turbine Emulation Experiment Aim: Study of static and dynamic characteristics of wind turbine (WT) by emulating the wind turbine behavior by means of a separately-excited DC motor using LabVIEW and

More information

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER K.Kalpanadevi 1, Mrs.S.Sivaranjani 2, 1 M.E. Power Systems Engineering, V.S.B.Engineering College, Karur, Tamilnadu,

More information

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR 120 CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR 6.1 INTRODUCTION For a long time, SCIG has been the most used generator type for wind turbines because of

More information

Wind Farm Evaluation and Control

Wind Farm Evaluation and Control International society of academic and industrial research www.isair.org IJARAS International Journal of Academic Research in Applied Science (2): 2-28, 202 ijaras.isair.org Wind Farm Evaluation and Control

More information

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS R. Vinu Priya 1, M. Ramasekharreddy 2, M. Vijayakumar 3 1 PG student, Dept. of EEE, JNTUA College

More information

Neural network based control of Doubly Fed Induction Generator in wind power generation.

Neural network based control of Doubly Fed Induction Generator in wind power generation. International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 Neural network based control of Doubly Fed Induction Generator in wind power generation. Swati A. Barbade 1,

More information

Sliding Mode Control of a Variable Speed Wind Energy Conversion System based on DFIG

Sliding Mode Control of a Variable Speed Wind Energy Conversion System based on DFIG Sliding Mode Control of a Variable Speed Wind Energy Conversion System based on DFIG Nihel Khemiri 1, Adel Khedher 2,4, Mohamed Faouzi Mimouni,1 1 Research unit ESIER, Monastir, Tunisia. khemirin@yahoo.fr

More information

Unit III-Three Phase Induction Motor:

Unit III-Three Phase Induction Motor: INTRODUCTION Unit III-Three Phase Induction Motor: The three phase induction motor runs on three phase AC supply. It is an ac motor. The power is transferred by means of induction. So it is also called

More information

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG) Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG) 1 Mali Richa Pravinchandra, 2 Prof. Bijal Mehta, 3 Mihir D. Raval 1 PG student, 2 Assistant Professor,

More information

UNC-Charlotte's Power Engineering Teaching lab

UNC-Charlotte's Power Engineering Teaching lab 1 UNC-Charlotte's Power Engineering Teaching lab B. Chowdhury Panel Session Title: Existing and Proposed Power Systems Laboratories for the Undergraduate Curriculum PES GM 2015 2 Outline Background - Energy

More information

Mathematical Modeling of DFIG for Reactive Power Loss Analysis and Controlling

Mathematical Modeling of DFIG for Reactive Power Loss Analysis and Controlling International Journal of Electrical Engineering. ISSN 0974-2158 Volume 4, Number 7 (2011), pp. 837-851 International Research Publication House http://www.irphouse.com Mathematical Modeling of DFIG for

More information

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment 2012 2nd International Conference on Power and Energy Systems (ICPES 2012) IPCSIT vol. 56 (2012) (2012) IACSIT Press, Singapore DOI: 10.7763/IPCSIT.2012.V56.2 Wind Power Plants with VSC Based STATCOM in

More information

International Journal of Advance Engineering and Research Development A THREE PHASE SENSOR LESS FIELD ORIENTED CONTROL FOR BLDC MOTOR

International Journal of Advance Engineering and Research Development A THREE PHASE SENSOR LESS FIELD ORIENTED CONTROL FOR BLDC MOTOR Scientific Journal of Impact Factor (SJIF): 4.72 e-issn (O): 2348-4470 p-issn (P): 2348-6406 International Journal of Advance Engineering and Research Development Volume 4, Issue 11, November -2017 A THREE

More information

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid Lluís Trilla PhD student Current topology of wind farm Turbines are controlled individually Wind

More information

Electrical Machines II. Week 5-6: Induction Motor Construction, theory of operation, rotating magnetic field and equivalent circuit

Electrical Machines II. Week 5-6: Induction Motor Construction, theory of operation, rotating magnetic field and equivalent circuit Electrical Machines II Week 5-6: Induction Motor Construction, theory of operation, rotating magnetic field and equivalent circuit Asynchronous (Induction) Motor: industrial construction Two types of induction

More information

H02P /00 Arrangements for stopping or slowing electric

H02P /00 Arrangements for stopping or slowing electric CPC H H02 COOPERATIVE PATENT CLASSIFICATION ELECTRICITY ( omitted) GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER H02P CONTROL OR REGULATION OF ELECTRIC MOTORS, ELECTRIC GENERATORS OR DYNAMO-ELECTRIC

More information

St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad

St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad-500 014 Subject: STATIC DRIVES Class : EEE III TUTORIAL QUESTION BANK Group I QUESTION BANK ON SHORT ANSWER QUESTION UNIT-I 1 What is meant by electrical

More information

International Journal of Advance Research in Engineering, Science & Technology. Comparative Analysis of DTC & FOC of Induction Motor

International Journal of Advance Research in Engineering, Science & Technology. Comparative Analysis of DTC & FOC of Induction Motor Impact Factor (SJIF): 3.632 International Journal of Advance Research in Engineering, Science & Technology e-issn: 2393-9877, p-issn: 2394-2444 Volume 3, Issue 4, April -2016 Comparative Analysis of DTC

More information

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Workshop on Grid Integration of Variable Renewable Energy: Part 1 Workshop on Grid Integration of Variable Renewable Energy: Part 1 System Impact Studies March 13, 2018 Agenda Introduction Methodology Introduction to Generators 2 Introduction All new generators have

More information

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application Issue #WP102: Technical Information from Cummins Generator Technologies Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application White Paper Ram Pillai

More information

Whitepaper Dunkermotoren GmbH

Whitepaper Dunkermotoren GmbH Whitepaper Dunkermotoren GmbH BG MOTORS WITH FIELD-ORIENTED CONTROL DR. BRUNO BASLER HEAD OF R&D PREDEVELOPMENT I DUNKERMOTOREN GMBH Dunkermotoren GmbH I Allmendstr. 11 I D-79848 Bonndorf I www.dunkermotoren.de

More information

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems LECTURE 19 WIND POWER SYSTEMS ECE 371 Sustainable Energy Systems 1 GENERATORS Blades convert the wind kinetic energy to a shaft power to spin a generator and produce electricity A generator has two parts

More information

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II REV. NO. : REV. DATE : PAGE: 1 Electro-mechanical Energy Conversion II 1. To perform no load and blocked rotor tests on a three phase squirrel cage induction motor and determine equivalent circuit. 2.

More information

International Journal of Advance Research in Engineering, Science & Technology

International Journal of Advance Research in Engineering, Science & Technology Impact Factor (SJIF): 3.632 International Journal of Advance Research in Engineering, Science & Technology e-issn: 2393-9877, p-issn: 2394-2444 (Special Issue for ITECE 2016) Field Oriented Control And

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 CONSERVATION OF ENERGY Conservation of electrical energy is a vital area, which is being regarded as one of the global objectives. Along with economic scheduling in generation

More information

ECE 325 Electric Energy System Components 6 Three Phase Induction Motors. Instructor: Kai Sun Fall 2016

ECE 325 Electric Energy System Components 6 Three Phase Induction Motors. Instructor: Kai Sun Fall 2016 ECE 325 Electric Energy System Components 6 Three Phase Induction Motors Instructor: Kai Sun Fall 2016 1 Content (Materials are from Chapters 13-15) Components and basic principles Selection and application

More information

CHAPTER 5 ANALYSIS OF COGGING TORQUE

CHAPTER 5 ANALYSIS OF COGGING TORQUE 95 CHAPTER 5 ANALYSIS OF COGGING TORQUE 5.1 INTRODUCTION In modern era of technology, permanent magnet AC and DC motors are widely used in many industrial applications. For such motors, it has been a challenge

More information

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS 66 CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS 4.1 INTRODUCTION In this chapter, the prototype hardware development of proposed

More information

DC CIRCUITS ELECTROMAGNETISM

DC CIRCUITS ELECTROMAGNETISM DC CIRCUITS 1. State and Explain Ohm s Law. Write in brief about the limitations of Ohm s Law. 2. State and explain Kirchhoff s laws. 3. Write in brief about disadvantages of series circuit and advantages

More information

IJSER. 1. Introduction. 2. Power flow of Doubly fed Induction Generator (DFIG) K. Srinivasa Rao 1 G. Kamalaker 2

IJSER. 1. Introduction. 2. Power flow of Doubly fed Induction Generator (DFIG) K. Srinivasa Rao 1 G. Kamalaker 2 International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May-2015 798 Hybrid Protection to Enhance the LVRT Capability of a Wind Turbine Based DFIG K. Srinivasa Rao 1 G. Kamalaker

More information

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER XXXX H02 GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER XXXX CONTROL OR REGULATION OF ELECTRIC MOTORS, GENERATORS, OR DYNAMO-ELECTRIC CONVERTERS; CONTROLLING TRANSFORMERS, REACTORS OR CHOKE

More information

Artificial-Intelligence-Based Electrical Machines and Drives

Artificial-Intelligence-Based Electrical Machines and Drives Artificial-Intelligence-Based Electrical Machines and Drives Application of Fuzzy, Neural, Fuzzy-Neural, and Genetic-Algorithm-Based Techniques Peter Vas Professor of Electrical Engineering University

More information

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June-2016 971 Speed control of Single-Phase induction motor Using Field Oriented Control Eng. Mohammad Zakaria Mohammad, A.Prof.Dr.

More information

A Simple Position-Sensorless Algorithm for Rotor-Side Field-Oriented Control of Wound-Rotor Induction Machine

A Simple Position-Sensorless Algorithm for Rotor-Side Field-Oriented Control of Wound-Rotor Induction Machine 786 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 48, NO. 4, AUGUST 2001 A Simple Position-Sensorless Algorithm for Rotor-Side Field-Oriented Control of Wound-Rotor Induction Machine Rajib Datta and

More information

Technical Guide No. 7. Dimensioning of a Drive system

Technical Guide No. 7. Dimensioning of a Drive system Technical Guide No. 7 Dimensioning of a Drive system 2 Technical Guide No.7 - Dimensioning of a Drive system Contents 1. Introduction... 5 2. Drive system... 6 3. General description of a dimensioning

More information

3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015)

3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015) 3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015) A High Dynamic Performance PMSM Sensorless Algorithm Based on Rotor Position Tracking Observer Tianmiao Wang

More information

Synchronous Generators I. EE 340 Spring 2011

Synchronous Generators I. EE 340 Spring 2011 Synchronous Generators I EE 340 Spring 2011 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is

More information

Lab Electrical Power Engineering I

Lab Electrical Power Engineering I INSTITUT FÜR ELEKTRISCHE MASCHINEN RHEINISCH-WESTFÄLISCHE TECHNISCHE HOCHSCHULE AACHEN Lab Electrical Power Engineering I Test 3: Induction machine with squirrel cage rotor and slip ring rotor 1 Experiment

More information

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors Journal of Magnetics 21(2), 173-178 (2016) ISSN (Print) 1226-1750 ISSN (Online) 2233-6656 http://dx.doi.org/10.4283/jmag.2016.21.2.173 Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal

More information

Control Strategy for DFIG Wind Turbine to Enhance LVRT under Various Faults

Control Strategy for DFIG Wind Turbine to Enhance LVRT under Various Faults Control Strategy for DFIG Wind Turbine to Enhance LVRT under Various Faults Gayathri.S.Nair 1, Krishnakumari.T 2 M.Tech Scholar, Dept. of EEE, ASIET Kalady, Mahatma Gandhi University, Kottayam, Kerala,

More information

SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC

SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC Fatih Korkmaz Department of Electric-Electronic Engineering, Çankırı Karatekin University, Uluyazı Kampüsü, Çankırı, Turkey ABSTRACT Due

More information

Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer. Public Information

Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer. Public Information Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer Content Introduction Electric Machines Basic and Advance Control Techniques Power Inverters and Semiconductor Requirements