1 Integration of Large Wind Farms into Electric Grids Dr Mohammad AlZoubi

2 Introduction

3 Development

4

5 WHAT IS NEXT!! Over the next 12 years, Europe must build new power capacity equal to half the current total.

6 WIND ENERGY ON LINE

7

8 WHAT WE ARE TALKING ABOUT?

9

10

11 Components

12

13 Disk Break System

14 Rotors

15

16

17 From where the problem of integration has been started?

18 0.66/11kV N

19 Reactive power requirements. Reactive power requirements. IG Q 1 P 1 P 2 Q 2 Infinite Bus P 3 P 4 consumer Q 3 Q 4 consumer

20 PFC 0.66/11kV N

21 FSWT vs VSWT

22

23 Wind and grid

24 Impact of Wind Power on the Angular Stability of a Power System There is no general statement possible. The stability depends on location of wind resources and the problem has to be analyzed individually for each case. The effect of type of generator technology in transit stability is very significant and the DFIG generator presents more performance than a other induction generators

25 HOWEVER HOWEVER

26

27

28

29

30

31 Single-line diagram of grid connected wind farm with synchronous generators

32 Single line diagram for HOFA WF

33 Wind Farms Best wind sites versus Weak Network. This has implications for the variation in network voltage caused by the constant changes in P and Q output of the WF. Despite the variation of wind speed due to wake, the large distances filter these variations. A strong correlation exists between the voltage variations and the stability of the system. Instability can cause the wind farm to shut down

34 Typical Arrangement of WF

35 An integrated wind energy conversion system

36

37

38

39

40 VOLTAGE INSTABILITY The main cause for voltage stability reduction is the demand of reactive power to the wind generators

41 Voltage and Torque profiles

42

43

44

45

46

47 F< <F< <F<47 47<F< <F< <F< <F< <F< <F<51.7 F>51.7 Frequency Hz INSTANTANEOUS 0.35 s 2 s 10 s 1.5 min 11 min permanent 11 min 1.5 min Instantaneous duration The requirement regarding the ability of protection systems to withstand the frequency variations listed in this Table is also applicable to any WF connected to TS through the DS.

48 Requirements of higher penetration Voltage stability

49 impact of fault location distance from IG bus on the voltage dip Voltage, [p.u] Fault location distance from IG bus (m) Fault location distance from IG, [m] (The fault is on the same feeder connected to IG) (The fault is on different feeder connected to IG)

50 Voltage drop Fault ride-through recovery profile The wind turbines must be able to continue uninterrupted operation under a transient voltage variation similar to the one illustrated below. 75% voltage drop for 250 ms Transient voltage sag 75% -250 ms 95% -0,5 sec. after fault 95% Seconds Small reduction of Output power (10%)

51 Voltage Sag Compensation Most WTs are programmed to disconnect themselves from the grid if voltage drops by 30% for 50ms The transmission system operators in many countries require ride-through capability for the wind farms to be integrated into the power network. Solution Power electronics substation or on-board electronics that can help wind farms ride-through faults by generating extra reactive power to hold the line voltage

52 Behavior at unbalanced grid faults Some grid codes such as the British Grid Code explicitly require that the wind park must ride through unbalanced faults without tripping offline. During such faults, reactive current needs to be injected as well.

53 Yearly frequency fluctuations histogram for a WF

54 Key aspects of WT behavior from the electricity industry perspective Starting transients Fluctuations in power output while operating Stopping transients

55 Sources of starting transients Starting transients arise from the (1) Initial imbalance between mechanical and electrical power flows (2) magnetic inrush phenomenon for IGs. Starting transients can be reduced by soft-start techniques.

56 Sources of Fluctuations in power output Fluctuations in power output arise from the (1) fluctuations in wind speed and direction (2) fluctuations in terminal voltage or frequency.

57 Sources of stopping transients Stopping transients arise from the (1) WT disconnection from an electricity NK. (2) Voltage and/or frequency disturbance propagating through the NK which may exceed voltage ratings or expose the rotor to unacceptable accelerating power.

58 Size and frequency of starting and stopping transients Size of starting and stopping transients of wind farm depends on the (1) Individual WT Size rather than wind farm. Whereas The frequency of starting and stopping transients is a function of the number of WTs in a farm.

59 STATCOM Solution STATCOM devices are pure power electronic devices made from IGBT, IGCT or GTO based converters to directly generate reactive currents. Compared to SVCs, STATCOMs are faster, smaller, and have better performances at reduced voltages. STATCOMS have the capability to address transient events.

60 Starting sequence for nine WTs in a 2MW wind farm

61 Output power of 2 wind farms located 80km apart over a 14-day period

62 Output power of 2 wind farms located 80km apart over a 3-day period

63 Prediction Problem

64 Example time series of online measurement and forecasts of wind power generation in Germany; forecasts with different forecast horizons are shown

65 Example time series of monitored and forecast power output for Germany

66 Compensation Schemes 1. Mechanically switched shunt capacitors 2. Static var Compensators (TCR, TCSC) 3. STATCOM 4. Power electronics converters (Inverter/Rectifier-DC link-inverter) Steady State events Transients events The power electronics interface depends on the source characteristics

67 The problem of harmonics The variable speed WTs are associated with usual problems of harmonic currents and reactive power demand of such equipment. Although of concern it appears that these disadvantages may be overcome especially if 12 pulse conversion equipment is used

68

69

70 WIND FARM CONFIGURATION

71 WIND FARM CONFIGURATION

72 Thank you for your patience

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,

More information

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators Abstract: G. Thrisandhya M.Tech Student, (Electrical Power systems), Electrical and Electronics Department,

More information

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1 Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1 CONTENTS Introduction Types of WECS PQ problems in grid connected WECS Battery

More information

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 61 CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 3.1 INTRODUCTION The modeling of the real time system with STATCOM using MiPower simulation software is presented in this

More information

ELG4125: Flexible AC Transmission Systems (FACTS)

ELG4125: Flexible AC Transmission Systems (FACTS) ELG4125: Flexible AC Transmission Systems (FACTS) The philosophy of FACTS is to use power electronics for controlling power flow in a transmission network, thus allowing the transmission line to be loaded

More information

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011 EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Fall 2011 Overview Environmental pressures have led many countries to set ambitious goals of renewable energy generation. Wind energy is the dominant renewable

More information

Targeted Application of STATCOM Technology in the Distribution Zone

Targeted Application of STATCOM Technology in the Distribution Zone Targeted Application of STATCOM Technology in the Distribution Zone Christopher J. Lee Senior Power Controls Design Engineer Electrical Distribution Division Mitsubishi Electric Power Products Electric

More information

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA Philippe Maibach, Alexander Faulstich, Markus Eichler, Stephen Dewar ABB Switzerland Ltd CH-5300 Turgi, Switzerland Phone: +41

More information

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE Yunqi WANG, B.T. PHUNG, Jayashri RAVISHANKAR School of Electrical Engineering and Telecommunications The

More information

Statcom Operation for Wind Power Generator with Improved Transient Stability

Statcom Operation for Wind Power Generator with Improved Transient Stability Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 4, Number 3 (2014), pp. 259-264 Research India Publications http://www.ripublication.com/aeee.htm Statcom Operation for Wind Power

More information

Analysis of Low Voltage Ride through Capability of FSIG Based Wind Farm Using STATCOM

Analysis of Low Voltage Ride through Capability of FSIG Based Wind Farm Using STATCOM Analysis of Low Voltage Ride through Capability of FSIG Based Wind Farm Using STATCOM Roshan Kumar Gupta 1, Varun Kumar 2 1(P.G Scholar) EE Department KNIT Sultanpur, U.P (INDIA)-228118 2 (Assistant Professor)

More information

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

ELECTRICAL POWER SYSTEMS 2016 PROJECTS ELECTRICAL POWER SYSTEMS 2016 PROJECTS DRIVES 1 A dual inverter for an open end winding induction motor drive without an isolation transformer 2 A Robust V/f Based Sensorless MTPA Control Strategy for

More information

Integrating Large Supplies of Wind Power - System Performance and Maintaining Quality of Supply in the Transmission Network

Integrating Large Supplies of Wind Power - System Performance and Maintaining Quality of Supply in the Transmission Network Grid Planning Dr. Winter Integrating Large Supplies of Wind Power - System Performance and Maintaining Quality of Supply in the Transmission Network ETG Conference Reliability of Power Supply on 5 February

More information

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN International Journal of Scientific & Engineering Research, Volume 6, Issue 0, October-05 Voltage stability of self excited wind induction generator using STATCOM Bharat choyal¹, R.K. Gupta² Electrical

More information

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Journal of American Science 2015;11(11)   Integration of wind Power Plant on Electrical grid based on PSS/E Integration of wind Power Plant on Electrical grid based on PSS/E S. Othman ; H. M. Mahmud 2 S. A. Kotb 3 and S. Sallam 2 Faculty of Engineering, Al-Azhar University, Cairo, Egypt. 2 Egyptian Electricity

More information

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Experience on Technical Solutions for Grid Integration of Offshore Windfarms Experience on Technical Solutions for Grid Integration of Offshore Windfarms Liangzhong Yao Programme Manager AREVA T&D Technology Centre 18 June 2007, DTI Conference Centre, London Agenda The 90MW Barrow

More information

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC Rong Cai, Mats Andersson, Hailian Xie Corporate Research, Power and Control ABB (China) Ltd. Beijing, China rong.cai@cn.abb.com,

More information

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid K. B. Mohd. Umar Ansari 1 PG Student [EPES], Dept. of EEE, AKG Engineering College, Ghaziabad, Uttar Pradesh, India

More information

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 01 July 2015 ISSN (online): 2349-784X Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC Ravindra Mohana

More information

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG C.Nikhitha 1, C.Prasanth Sai 2, Dr.M.Vijaya Kumar 3 1 PG Student, Department of EEE, JNTUCE Anantapur, Andhra Pradesh, India.

More information

Grid code Compliance and Renewable Energy Projects. Mick Barlow, Business Development Director, S&C Electric, United Kingdom

Grid code Compliance and Renewable Energy Projects. Mick Barlow, Business Development Director, S&C Electric, United Kingdom Grid code Compliance and Renewable Energy Projects Mick Barlow, Business Development Director, S&C Electric, United Kingdom Why Grid Codes? Permit the development of and operation of an efficient and economical

More information

THE IMPORTANCE OF INTEGRATING SYNCHRONOUS COMPENSATOR STATCOM IN WIND POWER PLANT CONNECTED INTO THE MEDIUM VOLTAGE GRID

THE IMPORTANCE OF INTEGRATING SYNCHRONOUS COMPENSATOR STATCOM IN WIND POWER PLANT CONNECTED INTO THE MEDIUM VOLTAGE GRID JOURNAL OF SUSTAINABLE ENERGY VOL. 7, NO. 1, MARCH, 016 THE IMPORTANCE OF INTEGRATING SYNCHRONOUS COMPENSATOR STATCOM IN WIND POWER PLANT CONNECTED INTO THE MEDIUM VOLTAGE GRID BERINDE I., BRAD C. Technical

More information

Possibilities of Distributed Generation Simulations Using by MATLAB

Possibilities of Distributed Generation Simulations Using by MATLAB Possibilities of Distributed Generation Simulations Using by MATLAB Martin Kanálik, František Lizák ABSTRACT Distributed sources such as wind generators are becoming very imported part of power system

More information

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Workshop on Grid Integration of Variable Renewable Energy: Part 1 Workshop on Grid Integration of Variable Renewable Energy: Part 1 System Impact Studies March 13, 2018 Agenda Introduction Methodology Introduction to Generators 2 Introduction All new generators have

More information

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR 120 CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR 6.1 INTRODUCTION For a long time, SCIG has been the most used generator type for wind turbines because of

More information

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network Nwozor Obinna Eugene Department of Electrical and Computer Engineering, Federal University

More information

Implementation of FC-TCR for Reactive Power Control

Implementation of FC-TCR for Reactive Power Control IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 5, Issue 5 (May. - Jun. 2013), PP 01-05 Implementation of FC-TCR for Reactive Power Control

More information

Effect of crowbar resistance on fault ride through capability of doubly fed induction generator

Effect of crowbar resistance on fault ride through capability of doubly fed induction generator ISSN: 2347-3215 Volume 2 Number 1 (January, 2014) pp. 88-101 www.ijcrar.com Effect of crowbar resistance on fault ride through capability of doubly fed induction generator V.Vanitha* and K.Santhosh Amrita

More information

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment 2012 2nd International Conference on Power and Energy Systems (ICPES 2012) IPCSIT vol. 56 (2012) (2012) IACSIT Press, Singapore DOI: 10.7763/IPCSIT.2012.V56.2 Wind Power Plants with VSC Based STATCOM in

More information

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 201

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP (  201 Study And Analysis Of Fixed Speed Induction Generator Based Wind Farm Grid Fault Control Using Static Compensator Abstract 1 Nazia Zameer, 2 Mohd Shahid 1 M.Tech(Power System) Scholar, Department of EEE,

More information

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Wind Energy 101: See Video Link Below http://energy.gov/eere/videos/energy-101- wind-turbines-2014-update Wind Power Inland and Offshore Growth in Wind

More information

A Review on Reactive Power Compensation Technologies

A Review on Reactive Power Compensation Technologies IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 11, 2017 ISSN (online): 2321-0613 A Review on Reactive Power Compensation Technologies Minal Dilip Sathe 1 Gopal Chaudhari

More information

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 12, Issue 3 Ver. II (May June 2017), PP 124-129 www.iosrjournals.org Comparative Analysis

More information

Electrical grid stability with high wind energy penetration

Electrical grid stability with high wind energy penetration ECOWAS Regional Workshop on WIND ENERGY Praia, Cape Verde. November 4 5, 2013 Electrical grid stability with high wind energy penetration Fernando CASTELLANO HERNÁNDEZ Head of Wind Energy Section Renewable

More information

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid Lluís Trilla PhD student Current topology of wind farm Turbines are controlled individually Wind

More information

Power Protection Discrete Automation & Motion South Africa

Power Protection Discrete Automation & Motion South Africa Carel Oberholzer, ABB South Africa, May 2013 PCS100 Power Protection Discrete Automation & Motion South Africa May 13, 2013 Slide 1 Power Protection Agenda 1. Introduction of power protection 2. Overview

More information

The Application of Power Electronics to the Alberta Grid

The Application of Power Electronics to the Alberta Grid The Application of Power Electronics to the Alberta Grid Peter Kuffel, Michael Paradis ATCO Electric APIC May 5, 2016 Power Electronics Semiconductor devices used in power transmission systems Types: Thyristor

More information

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Power Quality Improvement Using Statcom in Ieee 30 Bus System Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 3, Number 6 (2013), pp. 727-732 Research India Publications http://www.ripublication.com/aeee.htm Power Quality Improvement Using

More information

Regenerative Utility Simulator for Grid-Tied Inverters

Regenerative Utility Simulator for Grid-Tied Inverters Regenerative Utility Simulator for Grid-Tied Inverters AMETEK s RS & MX Series with the SNK Option provides the solution Testing of grid-tied inverters used in solar energy systems is emerging as a major

More information

Electric Power Delivery To Big Cities

Electric Power Delivery To Big Cities Problem Definition Electric Power Delivery To Big Cities a) Socio-economic incentives are a major factor in the movement of population to big cities b) Increasing demand of electric power has strained

More information

Critical Clearing Time and Voltage Stability of DG Integration in Lebanon: A Simulation Using MATLAB/SIMULINK

Critical Clearing Time and Voltage Stability of DG Integration in Lebanon: A Simulation Using MATLAB/SIMULINK Sep. 2013, Volume, No. (Serial No. ) Journal of Energy and Power Engineering, ISSN 1934-8975, USA Critical Clearing Time and Voltage Stability of DG Integration in Lebanon: A Simulation Using MATLAB/SIMULINK

More information

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS Prof. Suryanarayana Doolla Department of Energy Science and Engineering Indian Institute of Technology Bombay OUTLINE Intoduction Grid

More information

ABB FACTS Grid connection of Wind Farms

ABB FACTS Grid connection of Wind Farms Christian PAYERL ABB FACTS Grid connection of Wind Farms May 28, 2010 Slide 1 ABB Power of Wind May 28, 2010 Slide 2 ABB FACTS 300 engineers, highly skilled in the following disciplines: Development Marketing

More information

Overview of Flexible AC Transmission Systems

Overview of Flexible AC Transmission Systems Overview of Flexible AC Transmission Systems What is FACTS? Flexible AC Transmission System (FACTS): Alternating current transmission systems incorporating power electronic-based and other static controllers

More information

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality Surabaya Seminar 2014 Ferdinand Sibarani, Surabaya, 30 th October 2014 Power Quality Content 1. Power quality problems 2. ABB s low voltage (LV) solution PCS100 AVC (Active Voltage Conditioner) PCS100

More information

Renewable Energy Grid Integration and Distributed Generation Specialization Syllabus

Renewable Energy Grid Integration and Distributed Generation Specialization Syllabus Renewable Energy Grid Integration and Distributed Generation Specialization Syllabus Contents: 1. DISTRIBUTED GENERATION 2. GENERATION AND STORING TECHNOLOGIES 3. CONTROL TECHNIQUES AND RENEWABLE ENERGY

More information

Grid Stability Analysis for High Penetration Solar Photovoltaics

Grid Stability Analysis for High Penetration Solar Photovoltaics Grid Stability Analysis for High Penetration Solar Photovoltaics Ajit Kumar K Asst. Manager Solar Business Unit Larsen & Toubro Construction, Chennai Co Authors Dr. M. P. Selvan Asst. Professor Department

More information

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008 NB Power Customer Service and Distribution June 2008 Prepared by: Steven Wilcox Revised by: Steven Wilcox TABLE OF CONTENTS 1.0 Introduction 4 2.0 NB Power Policy on Independent Power Production 4 3.0

More information

PQC - STATCON The ultra fast Power Quality Compensator

PQC - STATCON The ultra fast Power Quality Compensator PQC - STATCON The ultra fast Power Quality Compensator PQC - STATCON The ultra fast power quality compensator PQC - STATCON is based on IGBT voltage source inverter technology. It is a shunt connected

More information

Doubly fed electric machine

Doubly fed electric machine Doubly fed electric machine Doubly fed electric machines are electric motors or electric generators that have windings on both stationary and rotating parts, where both windings transfer significant power

More information

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS) ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS) A wind energy conversion system (WECS) is composed of blades, an electric generator, a power electronic converter, and a control

More information

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE Richa jain 1, Tripti shahi 2, K.P.Singh 3 Department of Electrical Engineering, M.M.M. University of Technology, Gorakhpur, India 1 Department

More information

Standby Power Systems

Standby Power Systems Source: Power Quality in Electrical Systems Chapter 13 Standby Power Systems The term standby power systems describes the equipment interposed between the utility power source and the electrical load to

More information

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator Buletin Teknik Elektro dan Informatika (Bulletin of Electrical Engineering and Informatics) Vol. 2, No. 4, December 2013, pp. 272~277 ISSN: 2089-3191 272 A Variable Speed Wind Generation System Based on

More information

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation Dynamic Reactive Compensation Providing stability, security, and reliability to the grid Installing a STATCOM at one

More information

Wind Generation and its Grid Conection

Wind Generation and its Grid Conection Wind Generation and its Grid Conection J.B. Ekanayake PhD, FIET, SMIEEE Department of Electrical and Electronic Eng., University of Peradeniya Content Wind turbine basics Wind generators Why variable speed?

More information

Tiruchengode, Tamil Nadu, India

Tiruchengode, Tamil Nadu, India A Review on Facts Devices in Power System for Stability Analysis 1 T. Tamilarasi and 2 Dr. M. K. Elango, 1 PG Student, 3 Professor, 1,2 Department of Electrical and Electronics Engineering, K.S.Rangasamy

More information

[Kadam, 3(2): February, 2014] ISSN: Impact Factor: 1.852

[Kadam, 3(2): February, 2014] ISSN: Impact Factor: 1.852 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Stability and Power Compensation Techniques in Wind Farm Kadam D.P *1, Dr. Kushare B.E. 2 *1,2 Department of Electrical K. K.

More information

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM 1 Rohit Kumar Sahu*, 2 Ashutosh Mishra 1 M.Tech Student, Department of E.E.E, RSR-RCET, Bhilai, Chhattisgarh, INDIA,

More information

Introduction CONTENT Future of offshore wind energy in Europe Offshore wind energy in Spain Alternatives to the transmission system to the grid Compar

Introduction CONTENT Future of offshore wind energy in Europe Offshore wind energy in Spain Alternatives to the transmission system to the grid Compar OFFSHORE WIND FARM CONNECTIONS TO THE GRID Energy to Quality S.L. Santiago Arnaltes Gómez Introduction CONTENT Future of offshore wind energy in Europe Offshore wind energy in Spain Alternatives to the

More information

A Grid-Connected Dual Voltage Source Inverter with Power Quality Improvement Features Abstract

A Grid-Connected Dual Voltage Source Inverter with Power Quality Improvement Features Abstract Page number 1 A Grid-Connected Dual Voltage Source Inverter with Power Quality Improvement Features Abstract A voltage regulation and power flow control scheme for a wind energy system (WES) is proposed.

More information

POWER QUALITY ISSUES IN WIND DIESEL HYBRID POWER GENERATION SYSTEMS

POWER QUALITY ISSUES IN WIND DIESEL HYBRID POWER GENERATION SYSTEMS POWER QUALITY ISSUES IN WIND DIESEL HYBRID POWER GENERATION SYSTEMS BUNDA Ș. *University of Oradea, Universităţii no.1, Oradea, sbunda@uoradea.ro Abstract The purpose of this paper is to present main power

More information

Novel Control of PV Solar and Wind Farm Inverters as STATCOM for Increasing Connectivity of Distributed Generators

Novel Control of PV Solar and Wind Farm Inverters as STATCOM for Increasing Connectivity of Distributed Generators Western University Scholarship@Western Electronic Thesis and Dissertation Repository May 2013 Novel Control of PV Solar and Wind Farm Inverters as STATCOM for Increasing Connectivity of Distributed Generators

More information

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015 e EPRLAB FAQ v1.0 Page 1 / 8 e EPRLAB Electric Power Research Laboratory, EPRLAB is a high-tech power electronics company that has been specialized on design, manufacturing and implementation of industrial

More information

Experimental Resultsofa Wind Energy Conversion Systemwith STATCOM Using Fuzzy Logic Controller

Experimental Resultsofa Wind Energy Conversion Systemwith STATCOM Using Fuzzy Logic Controller Bulletin of Electrical Engineering and Informatics ISSN: 2302-9285 Vol. 5, No. 3, September 2016, pp. 271~283, DOI: 10.11591/eei.v5i3.593 271 Experimental Resultsofa Wind Energy Conversion Systemwith STATCOM

More information

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 100 CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 6.1 INTRODUCTION Conventional energy resources are not sufficient to meet the increasing electrical power demand. The usages of

More information

Transient Stability Improvement of a FSIG Based Grid Connected wind Farm with the help of a SVC and a STATCOM: A Comparison

Transient Stability Improvement of a FSIG Based Grid Connected wind Farm with the help of a SVC and a STATCOM: A Comparison International Journal of Computer and Electrical Engineering, Vol.4, No., February 0 Transient Stability Improvement of a FSIG Based Grid Connected wind Farm with the help of a SVC and a : A Comparison

More information

EPE 18 ECCE Europe: LIST OF KEYWORDS

EPE 18 ECCE Europe: LIST OF KEYWORDS EPE 18 ECCE Europe: LIST OF KEYWORDS AC machine AC-cable AC/AC converter Accelerators Acoustic noise Active damping Active filter Active Front-End Actuator Adaptive control Adjustable speed drive Adjustable

More information

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT 2 nd International Conference on Energy Systems and Technologies 18 21 Feb. 2013, Cairo, Egypt ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT Mohamed Ebeed 1, Omar NourEldeen

More information

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems Ben Huckaba, P.E. President & Principal Engineer 317-273-9841 benh@alphaeng.us Indiana University Bloomington,

More information

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System Raju Pandey, A. K. Kori Abstract FACTS devices can be added to power transmission and distribution systems at appropriate

More information

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System Mrs. Aparimita Pati,

More information

Dynamic Control of Grid Assets

Dynamic Control of Grid Assets Dynamic Control of Grid Assets ISGT Panel on Power Electronics in the Smart Grid Prof Deepak Divan Associate Director, Strategic Energy Institute Director, Intelligent Power Infrastructure Consortium School

More information

Module 3: Types of Wind Energy Systems

Module 3: Types of Wind Energy Systems Module 3: Types of Wind Energy Systems Mohamed A. El-Sharkawi Department of Electrical Engineering University of Washington Seattle, WA 98195 http://smartenergylab.com Email: elsharkawi@ee.washington.edu

More information

Robust Control Technique for Grid-connected Power Conditioner

Robust Control Technique for Grid-connected Power Conditioner Hitachi Review Vol. 63 (2014), No. 8 483 Featured Articles Robust Control Technique for Grid-connected Power Conditioner Hikaru Meguro Kazuya Tsutsumi Masaya Ichinose Tomomichi Ito Akira Kikuchi OVERVIEW:

More information

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads PQC-STATCON PPHVC-Power Quality Solutions Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads Contents What is poor power quality? Reasons for investing

More information

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID ROHIT GAJBHIYE 1, PRALAY URKUDE 2, SUSHIL GAURKHEDE 3, ATUL KHOPE 4 1Student of Graduation, Dept. of Electrical Engineering, ITM College of engineering,

More information

FACTS FOR GRID INTEGRATION OF LARGE OFFSHORE WIND FARMS BY MEANS OF AC

FACTS FOR GRID INTEGRATION OF LARGE OFFSHORE WIND FARMS BY MEANS OF AC FACTS FOR GRID INTEGRATION OF LARGE OFFSHORE WIND FARMS BY MEANS OF AC Rolf Grünbaum, Per Halvarsson ABB Power Technologies AB Introduction After decades in the starting block, wind power is finally taking

More information

Primary frequency control by wind turbines

Primary frequency control by wind turbines Presented at 22 3rd IEEE PES ISGT Europe, Berlin, Germany, October 4 7, 22 Primary frequency control by wind turbines DiplIng Michael Wilch Prof DrIng István Erlich Institute of Electrical Power Systems

More information

Distributed Energy Resources

Distributed Energy Resources Distributed Energy Resources WECC Data Subcommittee Rich Hydzik, Avista (ERSWG/DER Subgroup Lead) June 29, 2018 Why Are We Concerned About DER? Concern about changing generation fleet Large coal fired

More information

CIGRE US National Committee 2013 Grid of the Future Symposium. Facilitating Bulk Wind Power Integration Using LCC HVDC

CIGRE US National Committee 2013 Grid of the Future Symposium. Facilitating Bulk Wind Power Integration Using LCC HVDC CIGRE US National Committee 2013 Grid of the Future Symposium Facilitating Bulk Wind Power Integration Using LCC HVDC Introduction Many states in US need to meet their renewable energy mandate Wind energy

More information

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC Int. J. of P. & Life Sci. (Special Issue Engg. Tech.) Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC Durgesh Kumar and Sonora ME Scholar Department of Electrical

More information

Stability Study of Grid Connected to Multiple Speed Wind Farms with and without FACTS Integration

Stability Study of Grid Connected to Multiple Speed Wind Farms with and without FACTS Integration International Journal of Electronics and Electrical Engineering Vol. 2, No. 3, September, 204 Stability Study of Grid Connected to Multiple Speed Wind Farms with and without FACTS Integration Qusay Salem

More information

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS 88 CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS 5.1 INTRODUCTION The advances in power electronics technology have enabled the use of variable speed induction generators for wind energy

More information

Power Generation. PowerStore Renewable microgrid stabilization

Power Generation. PowerStore Renewable microgrid stabilization Power Generation PowerStore Renewable microgrid stabilization PowerStore Renewable microgrid stabilization ABB`s microgrids and renewable integration platform provides a modular and scalable solution that

More information

Essential Reliability Services Engineering the Changing Grid

Essential Reliability Services Engineering the Changing Grid Essential Reliability Services Engineering the Changing Grid Robert W. Cummings Senior Director Engineering and Reliability Initiatives i-pcgrid March 39, 2016 Change is Coming Characteristics and behavior

More information

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc. ASHRAE - Variable Speed Drives By Dan Watkins, LEED BD+C Bornquist, Inc. Adjustable Frequency Drive Fundamentals How does a VFD actually work VS Pumping Analysis VS Pumping Features Harmonics VFDs and

More information

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM Shaila Arif 1 Lecturer, Dept. of EEE, Ahsanullah University of Science & Technology, Tejgaon, Dhaka,

More information

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL 123 CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL 5.1 INTRODUCTION Wind energy generation has attracted much interest

More information

Transient Stability Improvement of Squirrel Cage Induction Wind Turbine Generator using Plugging Mode

Transient Stability Improvement of Squirrel Cage Induction Wind Turbine Generator using Plugging Mode International Journal for Research in Engineering Application & Management (IJREAM) Transient Stability Improvement of Squirrel Cage Induction Wind Turbine Generator using Plugging Mode 1 Soumitra S. Kunte,

More information

High Voltage Direct Current and Alternating Current Transmission Systems Conference. August Nari Hingorani

High Voltage Direct Current and Alternating Current Transmission Systems Conference. August Nari Hingorani High Voltage Direct Current and Alternating Current Transmission Systems Conference at EPRI Palo Alto CA August 30 31 2011 Scope of VSC Based Technology in HVDC and FACTS Nari Hingorani HVDC and FACTS:

More information

Transmission Problem Areas. Bulk power transfer over long distances Transmission Limitations/Bottlenecks have one or more of the following:

Transmission Problem Areas. Bulk power transfer over long distances Transmission Limitations/Bottlenecks have one or more of the following: Transmission Problem Areas Bulk power transfer over long distances Transmission Limitations/Bottlenecks have one or more of the following:» Steady-state stability limits» Transient stability limits» Power

More information

Steady State Voltage Stability Enhancement Using Shunt and Series FACTS Devices

Steady State Voltage Stability Enhancement Using Shunt and Series FACTS Devices University of New Orleans ScholarWorks@UNO University of New Orleans Theses and Dissertations Dissertations and Theses Summer 8-13-2014 Steady State Voltage Stability Enhancement Using Shunt and Series

More information

Hamdy S. K. El-Goharey, Walid A. Omran, Adel T. M. Taha

Hamdy S. K. El-Goharey, Walid A. Omran, Adel T. M. Taha 1 Military Technical College Kobry El-Kobbah, Cairo, Egypt 10 th International Conference on Electrical Engineering I. ICEENG 2016 Voltage Stability Investigation of the Egyptian Grid With High Penetration

More information

Lab Validation of PV Solar Inverter Control as STATCOM (PV-STATCOM) Rajiv K. Varma and Ehsan Siavashi

Lab Validation of PV Solar Inverter Control as STATCOM (PV-STATCOM) Rajiv K. Varma and Ehsan Siavashi 1 Lab Validation of PV Solar Inverter Control as STATCOM (PV-STATCOM) Rajiv K. Varma and Ehsan Siavashi The University of Western Ontario London, ON, CANADA rkvarma@uwo.ca Novel Concept Utilization of

More information

ABB Wind Power Solution

ABB Wind Power Solution Feng Li, Wind ISI, CNABB, November, 2016 ABB Wind Power Solution November 13, 2016 Slide 1 ABB deliveries from A to Z into the wind industry Wind power generation, transmission and integration, control

More information

INTRODUCTION. In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators,

INTRODUCTION. In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators, 1 INTRODUCTION 1.1 GENERAL INTRODUCTION In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators, there is a great need to improve electric

More information

Performance of FACTS Devices for Power System Stability

Performance of FACTS Devices for Power System Stability Indonesian Journal of Electrical Engineering and Informatics (IJEEI) Vol. 3, No. 3, September 2015, pp. 135~140 ISSN: 2089-3272 135 Performance of FACTS Devices for Power System Stability Bhupendra Sehgal*

More information

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT Prof. Chandrashekhar Sakode 1, Vicky R. Khode 2, Harshal R. Malokar 3, Sanket S. Hate 4, Vinay H. Nasre 5, Ashish

More information

Systematic Survey for Role of Reactive Power Compensating Devices in Power System

Systematic Survey for Role of Reactive Power Compensating Devices in Power System MIT International Journal of Electrical and Instrumentation Engineering, Vol. 3, No. 2, August 2013, pp. 89 94 89 Systematic Survey for Role of Reactive Power Compensating Devices in Power System Gaurav

More information