ELECTRICAL HAZARD EXAMPLES

Size: px
Start display at page:

Download "ELECTRICAL HAZARD EXAMPLES"

Transcription

1 ELECTRICAL HAZARD EXAMPLES UNFORTUNATELY, THE EVENTS LISTED BELOW ARE MORE COMMON THAN YOU WOULD EXPECT Circuit breaker does not open the circuit when operated manually or remotely. The contacts within single and three phase breakers may not open. One or more poles can and do occasionally stick in the closed (energized) position. Test before you touch any conductive material and test the load side of the circuit breaker after you place it in the open (de-energized) position. Disconnect switch does not open the circuit when operated manually or remotely. On three phase, gang operated disconnect switches one or more poles can and do stick in the closed position. Visually inspect and confirm ALL blades of the disconnect switch moved as expected. Test before you touch any conductive material and test the load side of the disconnect switch after you place it in the open position. Power Plant generator destroyed due to reverse power. Worker inadvertently closed the generator circuit breaker while the generator was at standstill. Power from the electrical grid flowed through the closed generator disconnect switch, then through the generator circuit breaker, reverse powering the generator and causing catastrophic failure. Plant personnel previously deactivated reverse power relay protection. Worker burned when multi-meter leads created arc/blast. Worker used test leads that did not have insulation on the end connected to the meter. While performing the test, one of leads unplugged from the meter and contacted the conductive compartment metal. The other end of the lead came into contact with 480 volts during the test. Use test leads that have insulation on both ends. Two workers killed when crane contacted high voltage overhead conductor. Crane operator caused serious burning/arcing between crane, conductor, and ground. Another worker tried to rescue crane operator and was immediately electrocuted. Plan to avoid contact when working near any nearby conductors. Teach safe rescue techniques and warn workers of hazards. Do not touch energized persons or equipment. Page 1 of 5

2 Worker electrocuted when rolling-up 120-volt extension cord. Worker did not un-plug the extension cord from the feed receptacle. The extension cord had a defect that exposed energized conductors. Un-plug cord before winding or un-winding. Inspect cords for defects. Worker seriously shocked and burned when digging postholes. Worker was using a powered auger to dig holes and made contact with an energized underground 4kv cable. The auger welded itself to the cable and tripped the power supply. The worker was taken to a hospital burn center for treatment. Worker did call the appropriate number to have underground utilities identified. The underground utility locating company representative did not identify the 13kv cable. Operating toggle on the molded case circuit breaker is broken. This prevents proper operation of the circuit breaker from the operating handle on the front of the circuit breaker compartment door. Even though the handle on the front of the compartment door moves to the desired position, it does not position the circuit breaker in the desired position. The linkage from the handle on the front of the compartment door to the circuit breaker toggle could also be defective or misaligned. Always open the circuit breaker compartment door and test the load side of the circuit breaker after you place it in the open position. Opening or Closing a high energy disconnect switch under load. Most disconnect switches are not designed as load break disconnects. Always use the associated circuit breaker or other safe methods to make or break load. Worker electrocuted trying to save person in contact with energized conductor. Never touch a person or equipment while it is energized. Take appropriate steps to de-energize the conductor before touching the person or equipment. Use specially designed rescue hooks or other appropriate insulating material to remove a person from contact with energized equipment. Racking-out or Racking-in a high-energy circuit breaker in the closed position. Most circuit breaker manufacturers incorporate systems that are designed to prevent racking-out (withdrawing) or racking-in (inserting) a high-energy circuit breaker into its compartment, in the closed position. On rare occasions, these systems may fail, or personnel may intentionally defeat these systems. Never rack-in or rack-out a high-energy circuit breaker while it is in the closed position. Use remote racking mechanisms.

3 Power Plant generator circuit breaker exploded. While troubleshooting the generator circuit breaker, the worker initiated a slow closing of the circuit breaker. The generator was near synchronous speed but the slow closure of the circuit breaker caused an out-of-sync condition stressing the generator and causing the circuit breaker to explode catastrophically. Two workers were severely burned when the oil in the circuit breaker ignited. This incident could have been avoided by simply opening the associated generator disconnect switch during the troubleshooting effort. Worker seriously injured using improper voltage tester. Worker used a voltage tester rated at 600 volts to test a 13kv conductor. Tester exploded and worker was burned. Arc/Blast severely injures several workers in and near circuit breaker compartment. While troubleshooting cause of a 4kv circuit breaker tripping, workers caused a tremendous arc/blast inside of the circuit breaker compartment. Using an insulation tester, the worker inadvertently inserted the probes into the bus (energized) ports and caused the air to ionize and create a phase-to-phase fault. Should have used insulating barriers and lockout/tagout to prevent this incident. Working on the wrong (energized) equipment. Worker did not confirm equipment was properly de-energized. Incorrect circuit breaker was locked-out/tagged-out. Worker did not test before touch. High Voltage detector did not indicate presence of voltage. One type of proximity voltage detector did not indicate when positioned at certain angles between conductors. Manufacturer claims there is a field cancelling effect that causes this problem. Read manufacturers warnings and use personal protective equipment. Working on the wrong (energized) equipment. Compartment doors were interchanged during previous station outage. Circuit breaker identification was not accurate. Serious attention to detail issue. More reason to TEST BEFORE TOUCH! Circuit breaker exploded when racked-in the compartment. 13kv circuit breaker exploded due to excessive dirt and moisture on the circuit breaker. Circuit breaker was not properly stored when outside of compartment.

4 Worker seriously burned when closing a disconnect switch. Worker did not know that someone failed to remove temporary protective grounding cables. Closing the disconnect switch initiated a ground fault and serious arc/blast. Workers killed working in and near circuit breaker compartment. Worker entered circuit breaker cubicle and caused an electrical arc/blast that burned him and two other workers near the compartment. All three died from serious burn injuries. Cause was not determined since all three workers died. De-energize entire bus when working in high-energy circuit breaker compartments. Use personal protective equipment to avoid or minimize injury. Worker lost arm when he came in contact with energized 13kv bushing on transformer. Someone moved a ladder that was used for several days to access top of a 13kv transformer. Worker assumed he was on the correct isolated/de-energized transformer. Lock ladders in-place. Rope-in safe work area. Attention to detail. Circuit breaker will not trip when trip mechanism is activated. Do not try to remove/rack-out a breaker that will not trip/open. De-energize the bus and follow approved procedures to remove defective circuit breakers. Use lockout/tagout and use personal protective equipment. Use remote racking mechanisms. Worker shocked after contact with energized 480-volt conductor. Worker used a high voltage detector with a threshold voltage of 1200 volts (this type of detector does not indicate voltage below 1200 volts), to test a 480-volt system. Proper selection, testing, and use of voltage testers/detectors are essential for safe performance. 13kv Generator destroyed when worker closed the generator disconnects. Worker was removing lockout/tagout components as prescribed on an approved form. Generator was off and worker did not realize that maintenance personnel left the generator circuit breaker in the closed position after they performed maintenance on the circuit breaker. The closed disconnect switch allowed energy to flow from the electrical grid through the disconnect switch, through the circuit breaker causing serious damage to the generator (reverse power), and disconnect switch. Worker avoided serious injury.

5 Worker swallowed wire connector (wire nut) while working on lamp ballast. Worker tried to replace lamp ballast while still energized. He had a wire nut in his mouth when he received an electrical shock that caused him to swallow the wire nut. He also suffered serious burn injuries to both hands. Lockout/tagout. Worker seriously burned while removing electrical meter from meter socket. Several cases involving meter socket arc/blasts have occurred in recent years. Remove the load before installing or removing the meter. Wear FR clothing and equipment to avoid burn injuries. Worker electrocuted while disconnecting 480-volt cord and plug connected equipment. Cord and plug connected equipment could cause serious arcs, and/or shock when operated under load. De-energize the equipment before connecting or disconnecting equipment that is cord and plug designed. Special connectors are available to make or break electrical connections under load. Many manufacturers offer equipment with interlocks that ensure the power or load is off before cord and plug equipment is connected or disconnected. MOST OF THE FATALITIES AND INJURIES SHOWN IN THESE EXAMPLES COULD HAVE BEEN AVOIDED/PREVENTED WITH THE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT (PPE). EVEN IF YOU MAKE A MISTAKE, PROPER FR CLOTHING AND EQUIPMENT MIGHT PROTECT YOU WHEN EXPOSED TO THE INTENSE HEAT OF AN ARC. LOCKOUT/TAGOUT AND OTHER PROCEDURES ARE ESSENTIAL FOR PREVENTING MOST OF THE INCIDENTS SHOWN IN THESE EXAMPLES. Page 5 of 5

AVOIDING ELECTROCUTION HAZARDS

AVOIDING ELECTROCUTION HAZARDS Print AVOIDING ELECTROCUTION HAZARDS MODULE DESCRIPTION This module will provide information that helps you recognize and avoid common electrocution hazards in your work environment. OBJECTIVES After completing

More information

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2012

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2012 Safety Services 16 th floor, Commerce Place Tel: 1-866-421-6929 10155 102 nd Street Fax: 780-427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS ELECTRICAL INCIDENTS IN ALBERTA January 1 to December 31,

More information

Definitions. Exposed part. Live or energized part. De-energized part

Definitions. Exposed part. Live or energized part. De-energized part Electrical Safety Definitions Exposed part Live or energized part De-energized part 1a Definitions De-energized exposed parts that are not locked/tagged are considered to be energized exposed parts 1b

More information

BP-Husky Refinery Toledo, OH

BP-Husky Refinery Toledo, OH BP-Husky Refinery Toledo, OH Document Type: Procedure Refinery Wide Procedure No.: SAF 095 Effective Date: 2/25/16 Owner: D. Clark Working on or near Energized Electrical Equipment Rev. No.: 6 Auth. By:

More information

ELECTRICAL SAFET Y FOR CONTRACTORS

ELECTRICAL SAFET Y FOR CONTRACTORS ELECTRICAL SAFET Y FOR CONTRACTORS TABLE OF CONTENTS Electricity Demands Respect... 2 Before Starting to Work Let Us Help You...2 Basic Rules for Electrical Safety...2 Common Dangers for Contractors...3

More information

Arc-Flash Mitigation Technologies. Dennis Balickie

Arc-Flash Mitigation Technologies. Dennis Balickie Arc-Flash Mitigation Technologies Dennis Balickie The purpose of the session is to provide an overall understanding of the strategic impact of arc-flash. Special focus is on the tactical means to minimize

More information

Safety Training Topic ELECTRICAL SAFETY

Safety Training Topic ELECTRICAL SAFETY Safety Training Topic Purpose of Meeting To remind workers that electrical hazards can result in a serious injury. To reinforce electrical safety rules. To consider ways to protect yourself from electrical

More information

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.

More information

STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA to

STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA to Safety Services th 16 floor, Commerce Place Tel 1-866/421-6929 10155 102 nd Street Fax 780/427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA 01 01 to 12 31 Regulations

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

Surface Regulations and Policies

Surface Regulations and Policies Surface Regulations and Policies COAL FATALITIES 1970-2002 350 300 250 200 150 100 50 0 1970 1973 1976 1979 1982 1985 1988 1991 1994 1997 2000 From January 1, 1970 through today, a total of 240 coal miners

More information

Electrical Hazard Three factors determine the resistance of a substance to the flow of electricity: conductors insulators extreme caution

Electrical Hazard Three factors determine the resistance of a substance to the flow of electricity: conductors insulators extreme caution Electrical Safety Electrical Hazard Three factors determine the resistance of a substance to the flow of electricity: What it is made of. Its size. Its temperature. Substances with very little resistance

More information

ELECTRICAL SAFETY-RELATED WORK PRACTICES

ELECTRICAL SAFETY-RELATED WORK PRACTICES ELECTRICAL SAFETY-RELATED WORK PRACTICES This checklist is provided to assist organizations in reviewing compliance with OSHA Standard 29 CFR 1910.331 through 1010.335. Refer to the complete Standard for

More information

Stay Safe Around Electricity Teacher s Guide

Stay Safe Around Electricity Teacher s Guide Stay Safe Around Electricity Teacher s Guide INTRODUCTION The Stay Safe Around Electricity activity booklet can be used as a follow-up to an electric utility presentation or as a stand-alone piece to teach

More information

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE Duty B: Power Distribution (600V and below) B-03: Troubleshoot 480V System Issued 06/01/98 Task Preview Troubleshoot 480V System The 480V distribution

More information

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2013

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2013 Safety Services 16 th floor, Commerce Place Tel: 1-866-421-6929 10155 102 nd Street Fax: 780-427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS ELECTRICAL INCIDENTS IN ALBERTA January 1 to December 31,

More information

Arc flash hazard mitigation

Arc flash hazard mitigation Low Voltage Products Arc flash hazard mitigation Each year more than 2,000 people are treated in burn centers with severe arc flash injuries. ABB designs and manufactures products and solutions to provide

More information

STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA to

STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA to Safety Services 16 th floor, Commerce Place Tel 1-866/421-6929 10155 102 nd Street Fax 780/427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA 01 01 to 12 31 Regulations

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

Unrestricted. S.Mukhopadhyay

Unrestricted. S.Mukhopadhyay Unrestricted S.Mukhopadhyay 10.09.15 Electrical safety A report says that every year 5500 Indians die due to electric shock and 800 due to electric fire. 12% work place death due to electrocution ELECTRICAL

More information

IB PowlVac ITE-HK Remote Racking Device

IB PowlVac ITE-HK Remote Racking Device IB-51802 PowlVac ITE-HK Remote Racking Device for use with ITE-HK 5kV & 15kV Circuit Breakers and PowlVac ITE-HK 5kV & 15kV Replacement Circuit Breakers Powered by Safety PowlVac ITE-HK Remote Racking

More information

Basic Electrical Safety

Basic Electrical Safety Basic Electrical Safety Concerned About Electricity? How many sets of holiday lights do you plug into one extension cord? Do you still use your hot and sparking electric drill? Is your vacuum cleaner s

More information

"ELECTRICAL SAFETY IN THE WORKPLACE"

ELECTRICAL SAFETY IN THE WORKPLACE MAJOR PROGRAM POINTS "ELECTRICAL SAFETY IN THE WORKPLACE" Part of the "GENERAL SAFETY SERIES" Quality Safety and Health Products, for Today...and Tomorrow Outline of Major Points Covered in the "Electrical

More information

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT All electrical systems and electrically energized equipment

More information

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock

More information

PRILIMINARY REPORT ON THE ACCIDENT AT RANTAMBE 132 KV SWITCHYARD 21 ST FEBRUARY 2011

PRILIMINARY REPORT ON THE ACCIDENT AT RANTAMBE 132 KV SWITCHYARD 21 ST FEBRUARY 2011 PRILIMINARY REPORT ON THE ACCIDENT AT RANTAMBE 132 KV SWITCHYARD 21 ST FEBRUARY 2011 DGM (MAHAWELI COMPLEX OFFICE) CEYLON ELECTRICITY BOARD MAHAWELI COMPLEX 07 th MARCH 2011 1 Detail of Accident The bus

More information

ELECTRICAL SAFETY. Safety Training For The Non-Qualified

ELECTRICAL SAFETY. Safety Training For The Non-Qualified ELECTRICAL SAFETY Safety Training For The Non-Qualified LANGUAGE OF ELECTRICITY Electricity: Negatively Charged Particles Moving Over A Conductor Current: Movement Of Electrons Along A Conductor Ground

More information

Electrical Hazards in Construction

Electrical Hazards in Construction Electrical Hazards in Construction WELCOME Tim Dawson Presentation developed by Dawson Safety Services - 2013 Dangers of Electrical Shock Currents above 10 ma* can paralyze or freeze muscles. Currents

More information

Illinois State University. Electrical Safety Procedure

Illinois State University. Electrical Safety Procedure Illinois State University Electrical Safety Procedure Illinois State University Facilities Management Revision Date: May 2014 Illinois State University Facilities Management Electrical Safety Procedure

More information

Could also be a Near Hit

Could also be a Near Hit A near miss is an unplanned event that did not result in a fatal injury but had the potential to do so. Only a fortunate break in the chain of events prevented an injury, fatality or damage; in other words,

More information

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET LESTRONIC II BATTERY CHARGER TAYLOR-DUNN 79-301-10 MODEL 13110-32 TYPE 24LC25-8ET AC Supply: DC Output: Battery Capacity: Specifications 120 volts, 60 Hertz, single-phase 24 volts, 32 amps Use only on

More information

Transfer Switch TS-50. Owner s Manual

Transfer Switch TS-50. Owner s Manual Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer

More information

Transfer Switch GPTS 30

Transfer Switch GPTS 30 Transfer Switch GPTS 30 Owner s Manual Table of Contents Introduction 2 Installation 3 Operational Testing 7 Troubleshooting 8 Hi-Pot Testing 9 Generator Note 10 Medical Appliances 10 Caution 10 Warranty

More information

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise Arc flash solutions catalogue Australia Safety solutions - Protecting employees and the enterprise The risk of an arc flash event is real An arc flash hazard is a proven significant and dangerous threat

More information

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification Table 3-3.9.1 Hazard Risk Classification Table 3-3.9.1 Hazard Risk Classification Panelboards rated 240 V and below Notes 1 and 3 - - - Circuit breaker (CB) or fused switch operation with covers on 0 N

More information

Electrical Safety. Introduction

Electrical Safety. Introduction Electrical Safety Introduction Electrical hazards 300 electrocutions every year in the U.S. Leading cause is insufficient training ALL were preventable What is Electricity? How Electricity Works Created

More information

Appendix B PCC Electrical Safety Training

Appendix B PCC Electrical Safety Training Appendix B PCC Electrical Safety Training ELECTRICAL SAFETY TRAINING OBJECTIVES OSHA regulations have been adopted on electrical safety-related work practices for general industry. These new standards

More information

Electrical Awareness for Construction Activities. Overhead Power Lines & Underground Cables

Electrical Awareness for Construction Activities. Overhead Power Lines & Underground Cables Electrical Awareness for Construction Activities Overhead Power Lines & Underground Cables Electrical Awareness for Construction Activities Electrical appreciation Agenda Overview of the electrical distribution

More information

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures NIGHT-LITE PRO II Electrical System Troubleshooting Guide and Procedures Allmand Bros. Inc. PO Box 888 1502 W. 4 th Ave. Holdrege NE 68949 USA 308-995-4495 Phone 800-562-1373 Toll-Free www.allmand.com

More information

What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES

What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES Electrical Safety What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES 2015 2 There are two forms of electricity Static electricity

More information

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION Page: 1 Instructions for the Type VCP-W Ground & Test Device (Simple) Upper Terminal Set Version IB131007EN Effective May 2015 Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear

More information

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL SAE J1772 AC Level 2 EVSE Model: 30A EVoCharge EVSE Wall Mount P/N: EV072-300-001A Version 2.0 IMPORTANT Read this manual thoroughly

More information

SAFETY BULLETIN ELECTRICITY THE RULES HOW TO STAY SAFE WHEN WORKING AROUND POWER LINES AMERICAN CONCRETE PUMPING ASSOCIATION

SAFETY BULLETIN ELECTRICITY THE RULES HOW TO STAY SAFE WHEN WORKING AROUND POWER LINES AMERICAN CONCRETE PUMPING ASSOCIATION SAFETY BULLETIN ELECTRICITY THE RULES HOW TO STAY SAFE WHEN WORKING AROUND POWER LINES AMERICAN CONCRETE PUMPING ASSOCIATION WWW.CONCRETEPUMPERS.COM Electricity The Rules 1. You MUST maintain 20 feet clearance

More information

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER SPECIFICATIONS: *Photo for reference only* Part number 8890439 Mode Select: Selects Battery Type Refer to Section 6. IMPORTANT: READ

More information

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod Eaton Corporation Moon Twp, PA. U.S.A. 15108 1 INTRODUCTION READ AND UNDERSTAND

More information

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

24 VOLT AUTOMATIC BATTERY CHARGER PART NO 24 VOLT AUTOMATIC BATTERY CHARGER PART NO. 957732 AC Input: DC Output: Battery Type: Specifications 230 volts, 50 hertz, 3.5 amps, single-phase 24 volts, 20 amps initially tapering to 6 amps 24 volt, 12

More information

LESTRONIC II BATTERY CHARGER MODEL 07210

LESTRONIC II BATTERY CHARGER MODEL 07210 LESTRONIC II BATTERY CHARGER MODEL 07210 PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read and be familiar with this entire manual

More information

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1 Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)

More information

EEI Occupational Safety & Health Committee Conference Public Safety Issues and Trends

EEI Occupational Safety & Health Committee Conference Public Safety Issues and Trends EEI Occupational Safety & Health Committee Conference Public Safety Issues and Trends Anthony J. Calega Vice President, Loss Control October 7, 2008 A E G I S AssociatedElectric Gas Insurance Services

More information

ELECTRICAL SAFETY. Leader s Guide. Marcom Group Ltd.

ELECTRICAL SAFETY. Leader s Guide. Marcom Group Ltd. 1902 ELECTRICAL SAFETY Leader s Guide Marcom Group Ltd. Structure and Organization Information in this program is presented in a definite order so that employees will see the relationships between the

More information

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards, Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards, battery charging, and battery maintenance. Although

More information

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ITS-50R TRANSFER SWITCH OWNER S MANUAL ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard

More information

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2017

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2017 Community and Technical Support 16 th floor, Commerce Place Tel: 1-866-421-6929 10155 102 nd Street Fax: 780-427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS ELECTRICAL INCIDENTS IN ALBERTA January

More information

OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER 1) INTRODUCTION 2) CAUTIONS 3) RECEIVING A) UNPACKING B) INSPECTION C) HANDLING D) STORAGE 4) INSTALLATION A) PRE-INSTALLATION

More information

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1 SAFETY FACT SHEETS Electrical Hazards Safety Non Negotiable G-HS-ST-00752 Electrical Hazards Safety Non-Negotiables (SNN) Zinfra Group is committed to providing a safe workplace in line with our number

More information

EZ Hauler 2500 Training & Procedure Manual

EZ Hauler 2500 Training & Procedure Manual EZ Hauler 2500 Training & Procedure Manual Load Capacity One of the most important considerations when operating this machine is the Load Capacity of the EZ Hauler 2500 s boom. The maximum weight capacity

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Electrical Safety World Video Teacher s Guide

Electrical Safety World Video Teacher s Guide Electrical Safety World Video Teacher s Guide The Electrical Safety World video explains electric science concepts and how to use electricity safely in daily life. The content addresses many state and

More information

ELECTRICAL. 60 Minutes

ELECTRICAL. 60 Minutes ELECTRICAL 60 Minutes AGENDA Electrical definitions Electrical shocks, burns and secondary injuries Electrical hazards in the workplace Safety devices and prevention steps Do s and Don ts INTRODUCTORY

More information

ESSENTIAL SAFETY RESOURCES

ESSENTIAL SAFETY RESOURCES ESSENTIAL SAFETY RESOURCES GS-3029 Originator: Safety Advisor s Signature: Type Name Approval: HSE Manager s Signature: Type Name Approval: Operations Manager s Signature: Type Name Table of Contents PURPOSE...

More information

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: 30A EVoCharge EVSE Model Number: EV072-300-001A Product Safety Certification: UL and cul Listed Description: SAE J1772 AC Level

More information

Electrical Safety. Facilitator Guide

Electrical Safety. Facilitator Guide Electrical Safety Facilitator Guide Contents Overview...................................................2 Tips For Conducting An Effective Training Session..................... Successful Safety Programs.......................................

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

CAL/OSHA ELECTRICAL LOW VOLTAGE

CAL/OSHA ELECTRICAL LOW VOLTAGE Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 7 Purpose The purpose of this program is to prevent injuries due to electrical exposure to low voltage (less than or equal to

More information

P80074 (150 amp connectors) P80071 (300 amp connectors)

P80074 (150 amp connectors) P80071 (300 amp connectors) Overview: The Restore-Lite Temporary Power Restoration System is a compact mobile transformer unit that contains a single-phase, floating-tap transformer designed to restore power to customers who have

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 1163714 1.5 AMP 12VOLT TRICKLE 1.5 AUTOMATIC AMP AUTOMATIC TRICKLE 1.5 AMP AUTOMATIC 12V12VOLT BATTERY CHARGER IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This product offers a wide range

More information

ELECTRICAL GROUNDING SAFETY PROGRAM

ELECTRICAL GROUNDING SAFETY PROGRAM ELECTRICAL GROUNDING SAFETY PROGRAM PURPOSE / SCOPE The purpose of this program is to ensure the proper installation, maintenance, inspection, and testing of equipment grounding conductors on construction

More information

OPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

OPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER OPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER 1) INTRODUCTION 2) CAUTIONS 3) RECEIVING A) UNPACKING B) INSPECTION C) HANDLING D) STORAGE 4) INSTALLATION A) PRE-INSTALLATION

More information

When power interruptions happen.

When power interruptions happen. When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage

More information

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S VOLTMETERS PHASERS a n d A C C E S S O R I E S Operating and Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E WA U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. PHONE 847.473.4980

More information

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version IB131018EN Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version Contents Description Page 1. Introduction...2 2. Description...2

More information

OBAE, OBAEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBAE, OBAEXU, ON BOARD Battery Chargers INTRODUCTION: The OBAE line of chargers are designed for the permanent installation on battery powered

More information

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE MODEL 600A 6 VOLT BATTERY CHARGER ASSOCIATE IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for the battery charger you have purchased.

More information

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

36 VOLT AUTOMATIC BATTERY CHARGER PART NO 36 VOLT AUTOMATIC BATTERY CHARGER PART NO. 957727 AC Supply: DC Output: Battery Type: Specifications 120 volts, 60 Hertz, 10 amps, single-phase 36 volts, 20 amps initially tapering to 6 amps 36 volt, 18

More information

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A. OPERATOR S MANUAL JUMP STARTER and DC Power Source Model No. 71489 CAUTION: Read and follow all Safety Rules and Operating Instructions before Every Use of this Product. SAVE THESE INSTRUCTIONS. Sears,

More information

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards Robert P. Hansen, P.E., PhD GE Specification Engineer Introduction Switchboards are a widely used type of equipment

More information

What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES

What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES Electrical Safety What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES 2015 2 There are two forms of electricity Static electricity

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program Medford Area Public School District 124 West State St School District: Medford, WI 54451 715 748 4620 Review Date(s): January 2018 Program Dave Makovsky Coordinator: Purpose and

More information

120-ELECTRICAL SAFETY PROGRAM

120-ELECTRICAL SAFETY PROGRAM 120.1 PURPOSE A. To set forth procedures for the safe use of electrical equipment, tools, and appliances at Central New Mexico Community College (CNM). 120.2 SCOPE A. This program applies to all CNM employees

More information

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC. INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material

More information

MODEL 6017 OPERATOR'S MANUAL

MODEL 6017 OPERATOR'S MANUAL MODEL 6017 OPERATOR'S MANUAL ASSOCIATE D IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for the battery charger you have purchased.

More information

Energized Electrical Work

Energized Electrical Work Manitoba STANDARD PROCEDURE INSTRUCTION Title Energized Electrical Work Department Supersedes SPI Dated N/A SPI 32-4 Effective Date MAR 30, 2012 Energized Electrical Work SPI 32-4 Page 1 of 9 STANDARD

More information

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers Instructions for Load Break Air Switch, Type LBF, for Power Centers The Westinghouse Type LB 1 F Switch is an air insulated, gang operated, three pole, two position link type load interrupter switch. The

More information

JBBA Incident 1-NOV Saih Al Ahmar Incident 12-May Barka Incident 10-SEP-2011.

JBBA Incident 1-NOV Saih Al Ahmar Incident 12-May Barka Incident 10-SEP-2011. JBBA Incident 1-NOV-2011. Saih Al Ahmar Incident 12-May-2001. Barka Incident 10-SEP-2011. Incident Detail Date of Incident : 1-NOV-2011 Location : JBBA District Saih AL-Ula. Actual Severity : 3 Fatalities.

More information

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM _ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take

More information

Hazards SAFETY CORNER. of Establishing an. Work Condition

Hazards SAFETY CORNER. of Establishing an. Work Condition Hazards of Establishing an Electrically Safe Work Condition Written By Tony Demaria & Dean Naylor, Tony Demaria Electric, Mose Ramieh, III, Power Generation & Testing When working around electrical equipment,

More information

NFPA 70E Electrical Safety in the Work Place. R. Casey 2/1/05

NFPA 70E Electrical Safety in the Work Place. R. Casey 2/1/05 NFPA 70E Electrical Safety in the Work Place R. Casey 2/1/05 The Other Electrical Hazard Arc flash: high-intensity intensity flash (eye damage) and superheated ball of gas (skin burns and melting)created

More information

Electrical test equipment for use on low voltage electrical systems

Electrical test equipment for use on low voltage electrical systems Electrical test equipment for use on low voltage electrical systems Guidance Note GS38 (Fourth edition) This general series guidance note is aimed at people (including electricians, electrical contractors,

More information

Safety Working with LV Drives

Safety Working with LV Drives US1008e_LV Drive Safety_C, April 2009 Safety Working with LV Drives Intended Audience Only qualified electricians and engineers are allowed to install and maintain a LV Drive Students of this training

More information

PSJ-2212, PSJ-3612, PSJ-4424

PSJ-2212, PSJ-3612, PSJ-4424 Model: PSJ-2212, PSJ-3612, PSJ-4424 Jump Starter and DC Power Source OWNER S MANUAL PSJ-2212 PLEASE SAVE THIS OWNER S MANUAL AND READ BEFORE EACH USE. This manual will explain how to use your jump starter

More information

The Shocking Truth About Electrical Safety Teacher s Guide

The Shocking Truth About Electrical Safety Teacher s Guide The Shocking Truth About Electrical Safety Teacher s Guide FOUR SIMPLE CONCEPTS ABOUT ELECTRICAL SAFETY 1. Electricity travels in a closed loop called a circuit. 2. Electricity flows easily through conductors,

More information

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance National Grid UK Electricity Transmission plc NATIONAL SAFETY INSTRUCTION and HIGH VOLTAGE METAL CLAD SWITCHGEAR WITH SPOUTS Copyright National Grid plc 2014, all rights reserved. No part of this publication

More information

Electrical Safety For Everyone. Leader s Guide

Electrical Safety For Everyone. Leader s Guide 4609 Electrical Safety For Everyone Leader s Guide ELECTRICAL SAFETY FOR EVERYONE This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION:

More information

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit

More information

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best. Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution

More information

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector

More information

Battery. Charger Model: Save Important Safety Instructions

Battery. Charger Model: Save Important Safety Instructions Owner's Manual Battery Charger Model: SS-51A-PE, 10 Amp Fully Automatic Battery Charger For 12 Volt Marine Deep Cycle & Automotive Batteries Save Important Safety Instructions Read Rules for Safe Operation

More information

DIY 15 Amp Portable Generator Transfer Switch

DIY 15 Amp Portable Generator Transfer Switch DIY 15 Amp Portable Generator Transfer Switch ------------------------------------------------------------------------------------------------- WARNING You MUST read these warnings before proceeding. This

More information

QPET, QPETXU Battery Chargers

QPET, QPETXU Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QPET, QPETXU Battery Chargers INTRODUCTION: The QPET line of chargers are designed for general purpose deep cycle batteries. They are an electronically

More information

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety SM-1700 Secondary Shunt Trip Coil Assembly Powered by Safety SM-1700 Secondary Shunt Trip Coil Assembly SM-1700 Contact Information Powell Electrical Systems, Inc. www.powellind.com info@powellind.com

More information