1 Don t Forget Fluorescent! Better Buildings by Design 2012 Howard Wolfman, PE February 8, 2012

2 Efficiency Vermont is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES for AIA members. Certificates of Completion for both AIA members and non-aia members are available upon request. This program is registered with AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

3 Disclaimer Although I list several manufacturers and models, these are examples and none are endorsed Also, I do not have any financial arrangement or consulting agreements with any of these manufacturers (friendships with some yes)

4 Fluorescent Remember Monty Python the Holy Grail Bring out your dead Well, Fluorescent isn t dead, yet!

5 Lighting Goal To safely place the correct amount and type of light where it is needed, when it is needed, and for the lowest life cycle cost To achieve goal, need Consistency in products Reliability in products Right products Cost effective products Then products will Allow interchangeability of system components Provide superior lighting

6 Learning Objectives Learn about the most innovative new lamp, ballast, and luminaire product introductions. Understand how these advances in technology compare to existing technology. Understand new technological and legislative trends in lamp and ballast design. Identify new lamp and ballast types and understand their implications for how lighting is designed and used.

7 Vermont

8 Efficient Lighting Fundamentals This morning s presentation will be Aimed towards commercial applications Targeted at the introductory level The presentation will cover Lamps Ballasts Some controls Luminaires aka fixtures, troffers Sustainability, Environmental, and maintenance

9 Energy Use and Cost for Lighting Systems in Commercial Buildings Cost of lamps (bulbs & tubes) and labor cost to replace them is small percentage of total operating costs. Electricity to operate lighting systems far outweighs lamp and labor costs. The higher purchase price of efficient lamps is quickly recovered through lower electricity costs. Source: BOC

10 Light Levels: Considerations Proper light levels required IESNA recommendations State/local standards Where light levels are correct, visual tasks are easier. Too little is bad cannot see, eye strain too much is bad glare, wastes energy Source: BOC

11 Some Definitions

12 Lamp Characteristics: LPW & Average Rated Life Lumens Per Watt (LPW) LPW = light output (lumens) power input (watts) Average Rated Life for Incandescent, HID, and Fluorescent is the point in time at which 50% of a large group of lamps have failed. Ratings in catalogs are result of standard lab tests. (Ex: Fluorescent lamps 20,000 3 hrs./start) Rated life for LED is when lumen output has dropped to 70%, or L70 Source: BOC

13 Light Source Efficacy (LPW) Source: BOC

14 Lamp Characteristics: Lumen Maintenance (lumen light depreciation) Most lamps lose ability to produce light after burning for some time Lumen maintenance measures the rate of depreciation and indicates the remaining light output LLD = mean lumens initial lumens* Ex: 32-w T8 Fluorescent 2,610 LLD = = ,900 *Initial lumens measured at 100 hrs. Source: BOC

15 Color Temperature of Fluorescent Lamps The color temperature represents the appearance of a lamp as rated in degrees Kelvin (K). Phosphor coating sets color temperature and CRI. Colors: 3000K (warm) 3500K (neutral) 4100K (cool) 5000K (daylight) 6500K (daylight) 8000K (SkyWhite) Source: BOC

16 Lamp Characteristics: Color Rendering Index (CRI) Appearance of colored objects when viewed under a light source compared to when viewed under daylight (of same color temp) Relative measure of up to 100 The higher the CRI, the truer the object colors appear. Source: BOC

17 Ballast Factor (BF) Is a value comparing the light output of a given fluorescent lamp and ballast combination, to the light output from the same lamp operating on a laboratory (perfect reactor) ballast. Light output is directly proportional to BF. Use BF to calculate light level for re lighting, or retrofit projects. Ballast factor computed by manufacturers and published in manufacturer s catalogs (or websites) Source: BOC

18 Light Source Color Summary CRI CCT ( K) Natural daylight o 8500 o Mercury vapor o 6000 o Metal halide o 6500 o Fluorescent o 8000 o Incandescent o 3000 o Induction o 5000 o Standard HPS o LED o 8000 o Low pressure sodium o Source: BOC

19 Florescent Lamps

20 Linear lamp sales (4 ft.)

21 Fluorescent Lamps: How they Work Source: BOC

22 T8 Fluorescent Lamps 1 diameter Linear lamps avail in 2, 3, 4, 5 & 8 lengths U tubes have 1 5/8 leg spacing Require ballast that supplies 265 ma (mostly electronic ballast) Retrofit U tube has 6 leg spacing Source: BOC

23 Reduced Wattage T8 Lamps Energy Saving T8 30 w, 28 w, 25 w Designed for spaces that can tolerate less light Advantages: Lower wattage, saves energy Disadvantages: Can be replaced with less expensive 32 w lamps Can be used with dimming ballasts (most lamps) Can not be used below 60 o F Source: BOC

24 Sylvania XP, SS and XPS lamps Rated life increased from 36,000 to 40,000 hours at 3 hours/start on PS ballast 24,000 to 37,500 hours at 1 hour/start 12,000 to 31,000 hours at 15 minutes/start Source: LFI 2011

25 Sylvania 23W, 25W, 28W, 30W Octron SuperSaver T8 lamps Dimmable! Source: LFI 2011

26 Sylvania 23W Octron SuperSaver T8 lamps 4 ft. 23W T8 lamps 2000 lumens 95% lumen maintenance 24,000/36,000 hours on IS 36,000/42,000 hours on PS 85 CRI 3500K, 4100K, 5000K Source: LFI 2011

27 Innovation: improving lamp life Extended life 4 ft. T8 lamps (XL, XLL, SXL) Up to 50,000 hours at 12 hours/start on IS ballast (industry average is 24,000 hours) Up to 55,000 hours at 12 hours/start on PS ballast (industry average is 30,000 hours) Improved life at shorter lamp cycles T5HO lamps are beginning to extend life: up to 60,000 hours at 12 hours/start Source: LFI 2011

28 Sylvania 800XP/XL T8 lamps 4 ft. 25W, 28W, 32W T8 lamps 50,000 hour rated life at 12 hours/start on instant start ballast 55,000 hours at 12 hours/start on programmed start ballast 44,000 hours at 30 minutes/start CRI 3500K, 4100K, 5000K Dimmable Source: LFI 2011

29 T5 Fluorescent Lamps 5/8 diameter lamp w/mini bi pin base Millimeter lengths Peak light output at 35C (95F) Operate on electronic ballasts Most effective in cove, indirect, & high-bay fluorescent fixtures Standard T5 most efficient 12 18% higher than T8 ( LPW) T5HO more lumens 10 15% less efficient than standard T5 About same efficiency as T8 Source: BOC

30 Innovation: efficient T5HO lamps Philips Energy Advantage: 49W T5HO (5W power reduction for same light output) GE T5HO Watt Miser: 51W (3W reduction for same light output) Sylvania Pentron SuperSaver Ecologic: 51W (3W reduction for same light output) GE T5HO Watt Miser Plus: 47W (7W reduction for 4% lower output) Sylvania Pentron HO SuperSaver: 47W (7W reduction for about 8% lower output) Source: LFI 2011

31 Philips Energy Advantage T5HO Extreme Temperature 49W direct replacements for 54W T5HO lamps Same light output >90% of rated lumens over ambient temperature of 65 F to 170 F Rated life of 35,000 hours Source: LFI 2011

32 Sylvania Pentron HO XL 4 ft. 54W T5HO lamps 60,000 hours at 12 hours/start Operates on same ballast 93% lumen maintenance 82 CRI 3000K, 3500K, 4100K, 5000K, 6500K Source: LFI 2011

33 Sylvania 2 and 3 ft. T5HO 20W and 35W energy saving T5HO lamps Replace 24W and 39W standard lamps respectively for up to 17% energy savings Replace lamp and keep ballast 85 CRI K Source: LFI 2011

34 Philips 25W Energy Advantage T5 Fluorescent Direct replacements for 28W T5 lamps to achieve 11% energy savings Same light output No ballast change required 3000K, 3500K, 4100K Rated life of 25,000 hours Source: LFI 2011

35 Legislation/Regulation 2009 DOE regulations will eliminate in 2012: most 4 ft. linear and 2 ft. U shaped T12 many 8 ft. T12 and T12HO some low CRI 4 ft. T8 BBD 2012 Copywrite 2012 Howard Wolfman, PE Lumispec Consulting Source: LFI 2011

36 LINEAR REPLACEMENT LAMPS

37 LED T8s There are hordes of sales people trying to sell these, because of potential huge volume and profit Often Pinocchio nose marketing hype But the DOE has not tested one yet is nearly as good as high performance fluorescent T8s with high performance ballasts Lamp cost can often range from $40 to $150 with proposed up to 50,000 hour realistic life Source: Stan Walerczyk LIGHTING WIZARDS:

38 LED T8s May void UL listing of fixture, that got UL listing as a fluorescent fixture How they are connected Some use existing fluorescent ballast, which consumes extra wattage, and the ballast would have to be replaced when it burns out Ballasts typically have a 50,000 60,000 hour rated life Some have internal driver, which requires removing existing fluorescent ballast and rewiring to lamp holders UL has found fire danger with some LED T8s with internally shunted lamp holders Some come with their external drivers Source: Stan Walerczyk LIGHTING WIZARDS:

39 Compact Fluorescent Lamps (CFLs) Screw base (numerous shapes 2 w to 200 w) Integral (ballast built in), or modular (detachable ballast) Twin and quad tube Preheat (5 w to 26 w) 2 pin, starter in base (blink blink on) Twin, triple, quad and hex tube RS (9 w to 120 w) 4 pin, instant on, dimmable (on electronic dimming ballasts) Source: BOC

40 SB Compact Fluorescent Lamps (CFL) Spring lamps One piece w/built in electronic ballast in base Sold under several name brands Disadvantages: Some made for residential market have shorter life ratings Source: BOC

41 CFLs Although some people give CFLs a bad wrap, CFLs are quite good in many applications Screw ins can often cost $0.25 with upstream rebates Lumens per watt are quite good CRI is quite good, typically in the 80s Life is much longer than incandescents Mercury is really not that much of an issue Although quite good, there are some drawbacks, and maybe best to consider a temporary solution Until LEDs or something else becomes ready for prime time Source: Stan Walerczyk LIGHTING WIZARDS:

42 CFLs New nice looking CFL Plumen BBD 2012 Copywrite 2012 Howard Wolfman, PE Lumispec Consulting Source: Stan Walerczyk LIGHTING WIZARDS:

43 CFL CFLs are reasonably efficacious, but Not nearly efficacious as high performance T8 systems Most are only rated for 10,000 12,000 hours Many recessed can fixtures for them have very bad fixture efficiency Like 50 60% But there are some CFL recessed cans with more like 75% fixture efficiency Usually best to try to Have just one lamp per fixture Minimize lamp types Source: Stan Walerczyk LIGHTING WIZARDS:

44 Induction Lamps Electrodeless Induction coil generates highfrequency field within lamp Similar to Fluorescent, mercury vapor generates UV energy, converted to visible light by phosphor coating 80 LPW; 85 CRI Discharge Vessel Phosphor Coating Power Coupler Source: BOC

45 Fluorescent Ballasts

46 Retrofit/Replacement vs. OEM (fluorescent ballast shipments) Source: LFI 2011

47 Ballasts Electrical devices to start and operate fluorescent lamps Functions: 1. Provides correct voltage to start arc discharge 2. Limits lamp current to design value 3. Provides energy to heat cathodes (fluorescent rapid start & program start only) A ballast prevents the destruction of a lamp by limiting lamp current Source: BOC

48 Fluorescent Lamps: How they Work Source: BOC

49 Fluorescent Ballasts Starting Modes Instant start (most popular) Rapid start (being phased out) Programmed start (replacing rapid start, designed for switching) Common Types Standard Magnetic (no longer made; no PCBs since 1979) Energy Saving Magnetic (1990 s) Hybrid Magnetic (stop gap technology) Electronic (high frequency operation of lamps) Dimming (electronic; new models are programmed start) Source: BOC

50 Programmed Start Electronic Ballasts Cost effective for switching applications Maintains energy efficiency while providing optimum starting conditions to obtain up to 100,000 starts Starts lamps by the precise application of voltage to heat cathodes for precise time before lamp ignition Reduces cathode voltage once the lamp has ignited Source: BOC

51 Ballast Factor & Light Output BF Performance Comparison of 2 F32T8 Lamps High Power Ballast Lumens / lamp 77 Watts Lumens / lamp 64 Watts Lumens / lamp 58 Watts Reference Ballast Normal Power Ballast Lumens / lamp 51 Watts Low Power Ballast Lumens Source: BOC

52 Extra Efficient Ballasts (NEMA Premium Ballasts) Extra efficient ballasts consume 3 6 watts less than generic electronic ballasts (GEB) Cost $1 $4 more Save $20 $40 in electric cost over ballast life Most new fixtures come with GEB (lowest cost) Source: BOC

53 High Performance T8 Systems: Super T8 From CEE and NEMA Premium Combination: high lumen, extended life lamps low BF, reduced wattage electronic ballast 15 20% more efficient than standard T8 systems Savings up to 40% when replacing 34 w T12 systems Identification: lamps with initial lumen ratings starting at 3100 lumens high lumen maintenance > 90% ( barrier coat technology) Source: BOC

54 Universal s Ultim8 highefficiency ballasts T8 lamps High efficiency electronic (NEMA Premium Ballast) 1, 2 and 3 and 4 lamp Programmed start operation Lamp start time near 0.5 seconds NEMA Premium Ballast Source: LFI 2011

55 Lutron EcoSystem reducedwattage ballast Digital 1% electronic dimming ballast Designed to operate reducedwattage T8 lamps (25W, 28W, 30W) Can operate standard and extendedlife lamps Factory tuned ballast with nonstandard ballast factors available Source: LFI 2011

56 LumenErgi ib 107 Intelligent dimming ballast Operates in DALI or 0 10VDC control modes High ballast factor (1.2 BF) Same ballast can operate 1, 2 or 3 T5 or T5HO lamps Universal voltage ( V at 50 or 60 Hz) Connects directly to occupancy and photosensors Source: LFI 2011

57 Innovation: tunable output Low BF Typically 0.77 or 0.78 High >1.0 BF Typically Normal BF Typically 0.87 or 0.88 New! 0.5+, 0.6, 0.71, 1.0 BF for T8 Source: LFI 2011

58 Sylvania 1.0 BF ballasts Two lamp high efficiency T8 instant start electronic ballast Medium BF of about % higher light output than typical normal BF ballast NEMA Premium Ballast Source: LFI 2011

59 GE UltraStart ballast T8 electronic ballast Programmed start, with same efficiency as instant start Specifiable with 0.6, 0.71, 0.89 and 1.15 BF Starts lamps in 0.5 seconds Operates lamps in parallel Universal voltage: V NEMA Premium Source: LFI 2011

60 Innovation: programmed start parallel lamp operation 4-Lamp Ballast Non-Parallel Parallel one lamp fails Source: LFI 2011

61 Programmed start parallel highefficiency T8 T8 lamp operation 1, 2 and 3 and 4 lamp Programmed start operation Parallel operation NEMA Premium Ballast Universal Ultim8 Sylvania PROStart Philips Optanium Source: LFI 2011

62 Programmed start parallel highefficiency T5HO T5HO lamp operation 4 lamp configuration Programmed start operation Parallel wiring with two lamps in series and two in parallel Philips Optanium Sylvania Quicktronic ProStart GE HE UltraStart Source: LFI 2011

63 Dimming Fluorescent Fluorescents with dimming ballasts can dim Input power is reduced, but lumens per watt gets worse, because the more dimming, the more power has to go to heating the cathodes of the lamps Dimming ballasts are more expensive CFLs have some special characteristics Dedicated dimmable screw ins usually cannot dim below 20% CFLs turn grayish or bluish when dimmed Source: Stan Walerczyk LIGHTING WIZARDS:

64 Dimming Fluorescent Ballasts Linear fluorescent Low voltage (2 wire, 0 10V) Power Line control from incandescent wall box dimmers Line control (extra 120V lead) (Lutron) Energy management applications 100% to 10% dimming range NEMA LL Dim to 10% Architectural dimming applications 100% to 1% Compact Fluorescent 4 pin rapid start lamps 18 w, 26 w quad lamps 32 w, 42 w triple lamps Source: BOC

65 Sylvania Quickstep Bilevel T8 Switching High efficiency programmed start T8 step dimming ballast Switch 100% to 50% power 1 or 2 4 ft, 3 ft, or 2 ft T8 lamps Low BF: 0.77BF, 0.25BF Normal BF: 0.87BF, 0.34BF NEMA Premium Ballast Source: LFI 2011

66 GE instant start load shed dim and bilevel UltraMax T8 load shed variable dimming ballast: Dim 100% 60% UltraMax hi/lo switching ballast: Switch 100% 60% 2, 3 and 4 lamp models being added to 6 lamp already available Both: Instant start operation, suitable for hi bay, 20 F cold start temp, 95% efficiency (NEMA Premium) Source: LFI 2011

67 Philips EssentiaLine dimming ballasts 0 10VDC dimming ballast 2 lamp T8 models with 0.88 BF Dim lamps from 100% to 20% Programmed start operation NEMA Premium Ballast Source: LFI 2011

68 GE s dimmable programmedstart parallel 0 10V dimming 100% to 3% light output 1, 2, 3 and 4 lamp T8 Multi voltage, normal (0.88) and high (1.18) ballast factor Fast start time of 0.7 seconds Parallel lamp operation NEMA Premium Ballast Source: LFI 2011

69 Sylvania QUICKTRONIC QHE DALI High efficiency dimming ballast for T5 lamps Dimming to 1% Operates 1 or 2 lamps Operates on DALI protocol Reports end of lamp life (when used with appropriate controls) Universal voltage ( V) Source: LFI 2011

70 Lutron H Series Digital 1% electronic dimming ballast Works with wired or wireless sensors Factory tuned ballast with non standard ballast factors available 0.5 BF up to published maximum in 0.01 increments 4 ft. T8 (1, 2 and 3 lamp) available in 1.0 and 1.17 BF Recent expansion includes 347V and universal voltage 3 T8 Source: LFI 2011

71 Electronic Ballast Advantages Higher efficiency (no transformer losses) Cooler operation (no transformer heat) Less weight (no core and coil) No noticeable flicker Smaller size 3 and 4 lamp designs (as well as 1 and 2 lamp) Parallel wiring models Colder starting (down to 0 degrees F) Dimming capabilities (down to 1% of output) (high frequency operation) (lower profile, less weight) (non burned out lamps remain on) Source: BOC

72 Legislation/Regulation Energy Policy Act of 2005 eliminates: Most magnetic ballasts for 4 and 8 ft. T12 lamps Ballast Rule of November 2011, effective November 2014: Changes the metric from BEF* to BLE* In addition to T12 ballasts, covers T8 and T5 ballasts *BEF (Ballast Efficacy Factor) = BF/Pin **BLE (Ballast Luminous Factor) = Pout/Pin BBD 2012 Copywrite 2012 Howard Wolfman, PE Lumispec Consulting Source: LFI 2011

73 Fluorescent Fixtures Source: BOC

74 TROFFERS

75 T8 Fluorescent There is a new generation of high performance 2x4 1F32T8 troffers that can be installed in typical 8x10 spacing Depending on BF and if instant or program start high efficient ballasts, are, used, wattage can range from with direct relationship to lumens Manufacturers and models include Deco DPL C (but may not be in website yet) Finelite HPR Source: Stan Walerczyk LIGHTING WIZARDS:

76 T8 Fluorescent Office with Finelite HPRs Source: Stan Walerczyk LIGHTING WIZARDS:

77 T8 Fluorescent Existing 2x4 troffers can be cost effectively retrofitted down to 1F32T8 Standard lensed troffers can often get a 1 cove white reflector About $55 $60 total installed cost Parabolic troffers can get upscale kits Such as ALP s RHT kit About $110 $120 total installed cost Source: Stan Walerczyk LIGHTING WIZARDS:

78 SUSPENDED INDIRECT/DIRECT FIXTURES

79 T8 Fluorescent Well designed suspended indirect/direct fixtures with 1F32T8 per cross section Can provide quite low power densities Total installed cost often less than individual troffers When can have relatively long rows in new construction and gut rehabs One lamp per cross section is usually much better than two or three for Optimal light distribution Usually batwing Best fixture efficiency Lowest wattage Lowest fixture cost Fixture cost may be $25 $40 per linear foot depending on type of fixture, quantity, etc. Source: Stan Walerczyk LIGHTING WIZARDS:

80 T8 Fluorescent Make sure fixture reflectors are designed for T8s and not for T5s/T5HOs There are many good manufacturers and models For example, Finelite offers several good models, including Series 12, 15 and 16 These are photos of Series 12 with white cross blade Source: Stan Walerczyk LIGHTING WIZARDS:

81 Wiring Tips Ground Fixtures Safety (required by NEC to protect personnel EMI Protection (discharge from Capacitors to ground) Provide Disconnects Protects personnel Easy maintenance Required by NEC Source: BOC

82 Fluorescent Lampholders (Sockets) Sockets in new fixtures with electronic ballasts cut into lamp pins line up indicator on tube with socket notch Excellent connection for high frequency Use shunted sockets for instant start ballasts Non shunted for dimming or programmed start incorrect correct incorrect Lamps not seated can cause them to malfunction Maintenance personnel can be shocked when touching bare pins Source: BOC

83 Retrofit vs. Re lighting Retrofit Re lighting Upgrade existing fixtures with efficient lamps, ballasts,.. If asbestos present in ceiling, then it s more cost effective Limited to lamp/ballast improvements Can be difficult to improve fixture efficiency Retrofit option can be more sustainable than re lighting due to material re use Improved when long life, high efficiency lamps are used Opportunity to optimize efficiency and change layout Opportunity to change more parameters of lighting system Number of lamps/fixture Number of fixtures/system Change to LED s? More electrical contractors know how to install new fixtures than know how to retrofit properly. Source: BOC

84 Retrofit: Reflectors Fluorescent kits available Example: 2x2 w/2 U tubes to 2 or 3,17 w T8 lamps, 2x4 w/4 lamps to 2 lamps Improve troffer efficiency Relocate lamps for max performance You must Perform trial installation Evaluate cost of retrofit fixtures versus replacement Source: BOC

85 Retrofit 400 MH to T8 Fluorescent Example Before After High-bay fixtures e/w 400-w metal halide (458-watts/fixture) 30 FC CRI = 65 Industrial fixtures e/w 6 F32T8 lamps (224-watts/fixture) 50 FC CRI = 85 Source: BOC

86 HID & Incandescent to T5HO Fluorescent Before 54, 400-w HPS HB fixtures 465-w 6, 400-w MH HB fixtures 458-w 4, 500-w Incand fixtures 500-w After 42, 4-lamp T5HO fixtures 234-w 4, 6-lamp T5HO fixtures 351-w (all e/w wire grills) Source: BOC

87 TASK AMBIENT LIGHTING Task ambient lighting is having relatively low Footcandle ambient lighting and additional task lighting when and where need it Light levels drop off exponentially as distance increases between source and task For example if double distance, 1/4 the footcandles Much less wattage getting high light levels from a task light 2 away from task, than from ceiling fixtures 6 away from task This strategy may be the most cost effective way to have very low power densities while providing good quality lighting In typical offices, usually watts per square foot is easily attainable Source: Stan Walerczyk LIGHTING WIZARDS:

88 TASK AMBIENT LIGHTING Ambient, in offices, works very well with either New or retrofitted 2x4 high performance troffers that have 1 high performance & often high Kelvin 32W F32T8 and high performance parallel wired program start ballasting Maybe tandem wire ballast per pair of troffers New or retrofitted suspended indirect/direct fixtures with 1 high performance & often high Kelvin 32W F32T8 per cross section and high performance parallel wired program start ballasting Ambient lighting can provide footcandles on desks Often more light is worse than less light, because more light can cause more glare and higher contrast ratios Source: Stan Walerczyk LIGHTING WIZARDS:

89 TASK AMBIENT LIGHTING For a long time most modular office systems had fluorescent under cabinet task lights But most of these fixtures Use way too much wattage Are glare bombs Provide too much light Often difficult to replace ballasts Sometimes still T12s with magnetic ballasts or T8s with magnetic ballasts There are some good CFL desk mount task lights But way too many people still use energy hog incandescent or quartz halogen Source: Stan Walerczyk LIGHTING WIZARDS:

90 TASK AMBIENT LIGHTING There are also integral or one piece fluorescent task ambient lighting systems One example is Tambient Source: Stan Walerczyk LIGHTING WIZARDS:

91 Fluorescent If you have T12 systems, definitely REPLACE Many existing T8 systems do not have the most efficient lamps or ballasts High performance T8 lamp and ballast systems can often save 20% wattage compared to old, generic T8 systems In many applications could go with a bi level system controlled by an occupancy sensor Before jumping into LEDs, good to raise the bar and see if they are cost effective compared to high performance T8 systems Source: Stan Walerczyk LIGHTING WIZARDS:

92 Sustainability, Environmental, and Maintenance

93

94

95

96 ARE LEDS REALLY MORE ENVIRONMENTALLY FRIENDLY? Yes, fluorescent, have mercury But the manufacturers have been doing a very good job reducing it Many states require recycling Many fixtures can be kept for a long time, because lamps and ballasts can be easily replaced LEDs do not contain any mercury But there are toxic chemicals used in production There is usually a lot of valuable aluminum or other metals used for heat sinks Many fixtures are currently not designed to be easily and cost effectively retrofitted Source: Stan Walerczyk LIGHTING WIZARDS:

97 More on Environmental No matter what you specify or buy, RoHS (Restriction of Hazardous Substances) compliant is highly recommended Already mandated in Europe For example, eliminates lead in solder Also mercury, cadmium, etc. Source: Stan Walerczyk LIGHTING WIZARDS:

98 What about long term Maintenance? Fluorescent fixtures can easily and cost effectively get new lamps and ballasts to last decades For example, parts and labor for a 2F32T8 fixture Group relamping every 25,000 hours may cost $10 Group reballasting every 50,000 hours may cost $40 $60 total at 50,000 hours with brand new lamps and ballast $70 total at 75,000 hours with brand new lamps and 1/2 old ballast $120 total at 100,000 hours with brand new lamps and ballast Source: Stan Walerczyk LIGHTING WIZARDS:

99 What about long term Maintenance? At 75,000 hours LED troffer Now with at least the Cree CR 2x2, 2x4 or 1x4 $325 initial parts and labor cost + $175 parts and labor retrofit cost = $500 High performance troffer with 1 F32T8 $225 initial parts and labor cost + $70 parts and labor relamping and reballasting = $295 Source: Stan Walerczyk LIGHTING WIZARDS:

100 Fluorescent Remember Monty Python the Holy Grail Bring out your dead Well, Fluorescent ain t dead, yet!

101 Course Evaluations In order to maintain high quality learning experiences, please access the evaluation for this course by logging into CES Discovery and clicking on the Course Evaluation link on the left side of the page.

102 Thank You are there any questions?????? Howard Wolfman, PE

103 Supplementary Data and Information

104 GE HL ,000 36,000 36,000 42,000 GE SXL ,000 40,000 40,000 46,000 PHILIPS ADV ,000 30,000 30,000 36,000 PHILIPS PLUS ,000 36,000 36,000 42,000 PHILIPS ADV XLL ,000 40,000 40,000 46,000 SYLVANIA XP ,000 40,000 40,000 42,000 SYLVANIA XPS ,000 40,000 40,000 42,000 SYLVANIA XP/XL ,000 52,000 60,000 62,000 GE SPX 28W ,000 30,000 36,000 42,000 PHILIPS ADV 28W ,000 30,000 30,000 36,000 SYLVANIA XP 28W ,000 40,000 40,000 42,000 SYLVANIA XP XL 28W ,000 52,000 60,000 62,000 GE SPX 25W ,000 40,000 40,000 46,000 PHILIPS ADV 25W ,000 30,000 30,000 36,000 PHILIPS ADV XLL 25W ,000 40,000 40,000 46,000 SYLVANIA XP 25W ,000 40,000 40,000 42,000 SYLVANIA XP XL 25W ,000 52,000 60,000 62,000 F28T , * * ,000 40,000 F54T5HO , * * ,000 40,000 Lamp manufacturers may alter rated lamp life and lumen specifications, so get updates from manufacturers. Source> w w w.lightingw izards.com Source: Stan Walerczyk LIGHTING WIZARDS:

105 lumen F32T8 basic grade F32T8 30W F32T8 28W F32T8 25W F32T8 extra long life 25W F32T G IS % EE IS % G IS % EE IS % G IS % EE IS % G IS % EE IS % G IS % EE IS % G IS % EE % PS EE % PS EE % PS EE #### % high lumen F28T typical F28T PS % W F28T5 26W high lumen F28T5 51W F54T5HO PS typical F54T5HO PS #### % F34T RS E % F34T12 CW RS M % notes: Lumens, lumen maintenance, ballast factors and wattages may vary among various manufacturers. In enclosed fixtures, since reduced wattage F32T8s consume less heat they can often operate closer to optimal 77 degrees F temperature, so may provide more light than this table shows compared to full wattage. Although efficacy can be improved with IS and RS ballasts with T5s and T5HOs, lamp life can be greatly reduced and lamp manufacturers may not warranty lamps. 93% is used as an average EOL lumen maintenance for T5HOs. 90% - 94% range among manufacturers. All wattages based on 277V. EE IS is extra efficient instant start. G IS is generic instant start. EE PS is extra efficient program start. PS is program start. RS E is rapis start electronic. RS M is rapid start magnetic. Extra long life is 36,000 hours with IS and 40,000 hours with PS ballasts at 3 hour cycles. Source: Source: Stan Walerczyk LIGHTING WIZARDS:

106 LED vs. FLUORESCENT T8s lumen 17W LED T8s ,000 (iffy in enclosed fixture) $43.89 $13.30 $ $ F34T12 CW 2650 lumen lamps, lumen long life 32W fluorescent F32T8s in outboard lamp holders & 2-lamp.89 BF high performance parallel wired program , $49.67 $15.05 $ ####### lamp energy start ballast lumen extra long life 32W saving fluorescent F32T8s in outboard lamp magnetic 144 $ , holders & 2-lamp 1.00 BF high 5428 ballasts, performance parallel wired program angled sides start ballast with good lumen long life 32W , $45.62 $13.83 $ ####### white paint & clear prismatic fluorescent F32T8s, 2-lamp.89 BF high performance parallel wired program start ballast & white , $49.67 $15.05 $ ####### lens reflector lumen long life 32W fluorescent F32T8s, 2-lamp 1.00 BF high performance parallel wired program start ballast & white reflector , $45.62 $13.83 $ ####### footnotes: Numbers in colored boxes can be changed, which automatically alters computations. Copyright of Stan Walerczyk, LC, principal of Lighting Wizards much less light long term Source: Stan Walerczyk LIGHTING WIZARDS:

107 LED vs. FLUORESCENT T8s $0.15 blended rate 3500 annual hours 1.1 reduced AC savings x $0.05 /KWH saved incentive 15 existing proposed type w atts appr. lamp life end of end of end of lamp life annual improved watt 3 life life 3 incenelect. retrofit and relamping options thermals watts reduc- elect. hour lamp lamp fixture hour tive cost and tion savings cycles lumens lumens lumens cycles fixture 3 basic grade 2800 lumen F32T8s, generic 3- lamp.88 BF electronic instant start ballast, angled sides with good white paint & clear prismatic lens 89 $ , lumen 17W LED T8s lumen long life 32W fluorescent F32T8s in outboard lamp holders & 2-lamp.89 BF high performance parallel wired program start ballast lumen extra long life 32W fluorescent F32T8s in outboard lamp holders & 2-lamp.89 BF high performance parallel wired program start ballast lumen long life 32W fluorescent F32T8s, 2-lamp.71 BF high performance parallel wired program start ballast & white 2x4 lensed troffer with 3 basic grade F32T8s reflector lumen long life 32W fluorescent F32T8s, 2-lamp.89 BF high performance parallel wired program start ballast & white reflector footnotes: Numbers in colored boxes can be changed, which automatically alters computations. Copyright of Stan Walerczyk, LC, principal of Lighting Wizards. November 11, 2011 version. 50,000 (iffy in enclosed fixture) cumulative years in long term benefit notes appr. installed cost payback (yrs) comprehensive long term benefit $21.95 $6.65 $ $ , $17.90 $5.43 $ $ , $17.90 $5.43 $ $ , $24.83 $7.53 $ $ , $17.90 $5.43 $ $ much less long term light Source: Stan Walerczyk LIGHTING WIZARDS:

108 $0.15 blended KWH rate 1.00 additional air conditioning savings (1.00 is none) $0.05 /KWH saved first year rebate 15 existing proposed application and fixture type watts annual hours annual electric cost option retrofit option description TYPICAL OFFICE 12' long x 10' wide x 9' high rated lamp life 3 hour cycles watts (some averaged) watts per square foot watts reduction % watts reduction annual unit electric cost savings appr installed cost rebate per year maintenance savings benefit for comprehensive long term benefit and payback per year improved worker productivity from improved lighting quality benefit for comprehensive long term benefit and payback per year combined maintenance savings and improved worker productivity benenfit for long term benefit and payback years of long term benefit payback in years just electricty payback in years comprehensive long term benefit just electricity long term benefit comprehensive A Retrofit each troffer with 3 25W F32T8 5000K lamps &.71 BF extra efficient program start parallel wired ballast 30,000-36, % $31 $120 $10 $2 $2 $ $349 $399 B Retrofit each troffer with upscale kit which eliminates parabolic louvers, 1 high lumen F32T8 5000K lamp & 1.15 BF extra efficient program start ballast 30,000-36, % $46 $230 $15 $6 $25 $ $474 $ x 10 x 9 office area with 2 2x4 18 cell parabolic troffers, each with 3 32W ,000 hour rated F32T8s and generic.88 BF ballasting (1.51 watts per square foot) $81.00 B1 B2 C C1 C2 F2 Retrofit each troffer with upscale kit which eliminates parabolic louvers, 1 high lumen F32T8 5000K lamp &.89 BF extra efficient program start ballast. Also include 8W LED task light. Retrofit each troffer with upscale kit which eliminates parabolic louvers, 1 high lumen F32T8 5000K lamp &.71 BF extra efficient program start ballast. Also include 2 8W LED task lights. 30,000-36,000 for T8s 30,000-36,000 for T8s Remove both troffers. Install 8' suspended indirect/direct 30,000 - fixture that has 2 high lumen F32T8 5000K lamps & ,000 BF extra efficient program start ballast. Remove both troffers. Install 8' suspended direct/indirect fixture that has 2 high lumen F32T8 5000K lamps &.89 BF extra efficient program start ballast. Also include 8W LED task light. Remove both troffers. Install 8' suspended direct/indirect fixture that has 2 high lumen F32T8 5000K lamps &.71 BF extra efficient program start ballast. Also include 2 8W LED task lights. Retrofit each troffer with 3 15W LED T8 lamps. Also include 2 8W LED task lights to provide sufficient light. 30,000-36,000 for T8s 30,000-36,000 for T8s 25,000-50, % $51 $310 $17 $6 $35 $ $470 $1, % $53 $380 $18 $6 $40 $ $434 $1, % $50 $410 $17 $6 $35 $ $349 $ % $53 $490 $18 $6 $45 $ $317 $1, % $54 $560 $18 $6 $50 $ $268 $1, % $34 $600 $11 $2 $2 $ $76 -$27 G Remove both troffers. Install 2 high performance LED troffers, set at full 41W, so sufficient light at end of life. 50, % $44 $650 $15 $8 $25 $ $26 $507 G1 Remove both troffers. Install 2 high performance LED troffers, set at 34W. Also include 8W LED task light. 50, % $47 $720 $16 $8 $35 $ $5 $634 G2 Remove both t8offers. Install 2 high performance LED troffers, set at 28W. Also include 2 7W LED task lights. 50, % $50 $790 $17 $8 $40 $ $31 $673 copyright of Stan Walerczyk of Lighting Wizards, 10/1/11 version Source: Stan Walerczyk LIGHTING WIZARDS:

2001 TMT Associates 1

2001 TMT Associates 1 Emerging Lighting Technologies Thomas M. Tolen, LC IEEE 3/21/01 TMT Associates, 2001 1 Overview New Lighting Technologies AB970 and The Crisis New Title 24 IEEE 3/21/01 TMT Associates, 2001 2 New Lighting

More information

Emerging Lighting Technologies IEEE - March 21, 2001

Emerging Lighting Technologies IEEE - March 21, 2001 Emerging Lighting Technologies Thomas M. Tolen, LC Overview New Lighting Technologies AB970 and The Crisis New Title 24 IEEE 3/21/01 TMT Associates, 2001 1 IEEE 3/21/01 TMT Associates, 2001 2 New Lighting

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Lighting Tables for New Equipment 3/9/2016

Lighting Tables for New Equipment 3/9/2016 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION

More information

Lighting Tables for New Equipment 2/24/2015

Lighting Tables for New Equipment 2/24/2015 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

2011 DOE Fluorescent Ballast Rulemaking. Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA July 2012

2011 DOE Fluorescent Ballast Rulemaking. Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA July 2012 2011 DOE Fluorescent Ballast Rulemaking Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA July 2012 New U.S. DOE Fluorescent Ballast Standards 2011 DOE Fluorescent Ballast Rulemaking Finalized

More information

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants

More information

Lighting Tables for Existing/Base Equipment 1/1/2014

Lighting Tables for Existing/Base Equipment 1/1/2014 T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO

More information

Lighting Tables for New Equipment 1/1/2018

Lighting Tables for New Equipment 1/1/2018 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00

More information

LED LIGHTING LED LIGHTING. October 1 st Energy Into Action

LED LIGHTING LED LIGHTING. October 1 st Energy Into Action LED LIGHTING LED LIGHTING October 1 st 2014 Energy Into Action LED LIGHTING Agenda: -Overview-LEDs -The top applications for LEDs in the workplace from warehouses to manufacturing plants to commercial

More information

Steve Sindoni Commercial Engineer OSRAM Sylvania

Steve Sindoni Commercial Engineer OSRAM Sylvania Steve Sindoni Commercial Engineer OSRAM Sylvania Lighting Energy Efficient Product & Industry Update A Brief Overview of Energy Efficient Lighting Systems -T8 & T5 systems -Energy management ballasts

More information

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note:

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: 1. This application is for new high efficiency lighting fixtures, systems and controls. 2. Cut sheets/specifications including

More information

F32T8SPP41EC0CV 32W T8 48" 4100K Coated

F32T8SPP41EC0CV 32W T8 48 4100K Coated 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Weight per unit Product Category s Product Type F32SPP41EC0CV 32W 48" 4100K Coated G.E. Lighting

More information

CRASH COURSE ON LED TECHNOLOGY & XCEL ENERGY REBATES KYLE HEMMI & JACKIE DUCHARME

CRASH COURSE ON LED TECHNOLOGY & XCEL ENERGY REBATES KYLE HEMMI & JACKIE DUCHARME CRASH COURSE ON LED TECHNOLOGY & XCEL ENERGY REBATES KYLE HEMMI & JACKIE DUCHARME 4-5-16 AGENDA Xcel Energy- LED prescriptive rebates available LED technology trends How much can I save and why? Where

More information

Electronic Fluorescent Ballasts

Electronic Fluorescent Ballasts Electronic Fluorescent Ballasts A Complete Range of Solutions From The Name You Trust For more than 30 years, the lighting industry has relied on our TRIAD brand for the most specified, most installed,

More information

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Bob Trate - CPMR Philips/Advance Ballasts April 20, 2010 Fluorescent Ballast Overview There are several generations and design

More information

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting High Bay Lighting Solutions WORKING INSTANTLY, QUIETLY FOR REMARKABLE ENERGY SAVINGS Universal Lighting Technologies

More information

The new standards affecting the lighting industry. Educating you now and into the future.

The new standards affecting the lighting industry. Educating you now and into the future. www.sylvania.com The new standards affecting the lighting industry. Educating you now and into the future. A handy guide to understanding and complying with the new lighting legislation Federal legislation

More information

HOW IS LIGHT PRODUCED

HOW IS LIGHT PRODUCED HOW IS LIGHT PRODUCED The fluorescent lamp produces light by the passage of an electric current flowing through a vapor of mercury. 1.Electron emitted from electrode collides with mercury atom. 2.Impact

More information

4' Planar Suspended and Surface LED Light Level Outputs. Lumens Delivered. Efficacy (LPW)

4' Planar Suspended and Surface LED Light Level Outputs. Lumens Delivered. Efficacy (LPW) PLANAR S2E Series The uniquely designed Planar from Metalumen features a slim sleek profile. While the over all body height is 2.2 inches [55mm] the actual edge viewed thickness is approximately 3/4 inches

More information

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY 08625-0350 CHRIS CHRISTIE GOVERNOR KIM GUADAGNO Lt. Governor January 18, 2011 LEE A. SOLOMON

More information

QUICKTRONIC ICE Universal Voltage Systems

QUICKTRONIC ICE Universal Voltage Systems QUICKTRONIC ICE Universal Voltage Systems Electrodeless Fluorescent Systems Lamp / Ballast Guide lamp: ICE 40W QT1x40ICE/UNV lamp: ICE 70W QT1x100ICE/UNV lamps: ICE 100W QT1x100ICE/UNV QT1x150ICE/UNV lamp:

More information

FROM YE OLDEN DAYS OF EFFICIENT LIGHTING TO TODAY S STANDARDS FOR EFFICIENCY. WE LL DISCUSS WHY EACH TECHNOLOGY WAS

FROM YE OLDEN DAYS OF EFFICIENT LIGHTING TO TODAY S STANDARDS FOR EFFICIENCY. WE LL DISCUSS WHY EACH TECHNOLOGY WAS Lighting Efficiency FROM YE OLDEN DAYS OF EFFICIENT LIGHTING TO TODAY S STANDARDS FOR EFFICIENCY. WE LL DISCUSS WHY EACH TECHNOLOGY WAS BETTER, BUT MAY NOT STILL BE THE WINNER OF YOUR BATTLE TO BALANCE

More information

TRUET5 EXT (DIMMABLE)

TRUET5 EXT (DIMMABLE) t all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. TRUET5 EXT (DIMMABLE) www.trulygreensolutions.com

More information

Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN Ph:

Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN Ph: Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN 56187 Ph: 5073727331 Business Member Information Company name Billing address Phone Installation address

More information

Lighting Rebate large business retrofit Instructions for completing the Retrofit LIGHTING Rebate Worksheet

Lighting Rebate large business retrofit Instructions for completing the Retrofit LIGHTING Rebate Worksheet Instructions for completing the Retrofit LIGHTING Worksheet General Note 1. This application is for replacing existing interior lighting fixtures or systems with new higher efficiency lamps, ballast and

More information

Section A: CUSTOMER INFORMATION. Customer Name Electric Account Number Rate Application Number. Facility Address City State Zip Code

Section A: CUSTOMER INFORMATION. Customer Name Electric Account Number Rate Application Number. Facility Address City State Zip Code Commercial & Municipal Retrofit 2015 Lighting Rebate Section A: CUSTOMER INFORMATION Customer Name Electric Account Number Rate Application Number Facility Address City State Zip Service Location Identification

More information

An Another One Bites the Dust! Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA April 2012

An Another One Bites the Dust! Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA April 2012 An Another One Bites the Dust! Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA April 2012 Disclaimer for external presentations in the United States: This document constitutes neither

More information

Photo Z.Jedrus. High performance, energy-efficient linear fluorescent lamps. Philips T8 Collection

Photo Z.Jedrus. High performance, energy-efficient linear fluorescent lamps. Philips T8 Collection Photo Z.Jedrus. High performance, energy-efficient linear fluorescent lamps Philips T8 Collection Philips T8 4 foot fluorescent lamps featuring ALTO lamp technology Offering long life, the industry s

More information

CR Series and DR Series LED Downlights EASY TO INSTALL WITH UNPRECEDENTED PAYBACK

CR Series and DR Series LED Downlights EASY TO INSTALL WITH UNPRECEDENTED PAYBACK CR Series and DR Series LED Downlights EASY TO INSTALL WITH UNPRECEDENTED PAYBACK The Quality You Demand with the Savings You Deserve. Inspired by Your Needs SOLUTIONS THAT DELIVER Cree CR Series and DR

More information

Table of Contents T8 Instant Start Ballasts

Table of Contents T8 Instant Start Ballasts Table of Contents T8 Instant Start Ballasts gelighting.com Ballasts Understanding T8 Fluorescent Ballasts...10-2 Understanding Fluorescent Systems...10-3 Fluorescent Ballast Application Notes...10-5 UltraMax

More information

So, You re Thinking About Converting to LEDs?

So, You re Thinking About Converting to LEDs? So, You re Thinking About Converting to LEDs? For More Information Please contact: Roberts Research & Consulting, Inc. 3 Garrison Road, Burnt Hills, NY 12027 vic25@robertsresearchinc.com Don t forget to

More information

SubstiTUBE IPS LED T8

SubstiTUBE IPS LED T8 www.sylvania.com/led SubstiTUBE IPS LED T8 Compatible LED T8 for use with instant start and select programmed rapid start electronic T8 ballasts Key Features & Benefits Optimized glass optics available

More information

Pretest Module 15 Units 1, 2, 3, 4

Pretest Module 15 Units 1, 2, 3, 4 Pretest Module 15 Units 1, 2, 3, 4 1. What is the light-sensitive surface at the back of the eye? Retina 2. What is the transparent outer membrane surrounding the eye? Cornea 3. What four objective factors

More information

LED Lighting Initiative. Presentation for Sales February 14, Time to catch the wave!

LED Lighting Initiative. Presentation for Sales February 14, Time to catch the wave! LED Lighting Initiative Presentation for Sales February 14, 2018 Time to catch the wave! LED Lighting is EXPLODING Reduce energy consumption by up to 80% Increase product life up to 20X longer Increase

More information

VEL2P75S35I 2-F96T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2P75S35I 2-F96T12 277V Electronic Ballast Philips Advance Catalog Number VEL2P75S35I Manufacturer Philips Advance Description

More information

Be Off The Grid com Inc.

Be Off The Grid com Inc. Shoebox LED Retrofit Before 400w Metal Halide After 93w LED Retrofit screw-in Save UP To 75-80% in Energy Cost 5 Year Warranty Life Expectancy 100,000 + hrs. NO NEED TO PURCHASE A NEW FIXTURE. OURS FITS

More information

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number.

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number. Lighting Rebate 125 Minnesota Valley Electric Dr. Jordan, MN 55352 Ph: 952.492.2313 Fax 952.492.8281 Business Member Information Company name Billing address Phone Installation address (if different from

More information

Energy Saving Options for Small ISDs. Presented by Casey Stone, PE, CEM

Energy Saving Options for Small ISDs. Presented by Casey Stone, PE, CEM Energy Saving Options for Small ISDs Presented by Casey Stone, PE, CEM True Story*.. Big City ISD has lots of students & budget, and has been building new schools Each new school was carefully designed

More information

Samsung LED lighting: MR16. Samsung LED lighting: PAR. Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications

Samsung LED lighting: MR16. Samsung LED lighting: PAR. Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications Samsung LED lighting: MR16 Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications Samsung LED lighting: PAR Adjustable, high-performing, low-energy LED lamps Samsung

More information

ECO EXT (DIMMABLE)

ECO EXT (DIMMABLE) Not all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. ECO EXT (DIMMABLE) www.trulygreensolutions.com

More information

LED Lumina USA s Green Initiative

LED Lumina USA s Green Initiative 6-2017 LED Lumina USA s Green Initiative Reasons To Consider LED Replacement Bulbs vs. T8 Fluorescent Bulbs Here are 6 solid, factual based reasons why you should consider DIRECT Replacement LED Bulbs

More information

What s Next for Lighting Programs? Rocky Mountain Utility Exchange October 11, 2012

What s Next for Lighting Programs? Rocky Mountain Utility Exchange October 11, 2012 What s Next for Lighting Programs? Rocky Mountain Utility Exchange October 11, 2012 Platte River-City Relationship Residential Commercial Generation Transmission Platte River Power Authority Sole Supplier

More information

LED Indoor Lighting Product Guide

LED Indoor Lighting Product Guide LED Indoor Lighting Product Guide 120 Rowell Road Hampshire, IL 60140 847-302-8998 Phone 847-683-8002 www.ledrite.com LT Model T8 Series T8 LED TYPE C EXTERNAL DRIVER 2FT X 2 RETROFIT KIT This T8 LED 2FT

More information

LIGHTING SPECIFICATIONS

LIGHTING SPECIFICATIONS Incentives: Specifications LIGHTING SPECIFICATIONS All lighting projects are expected to comply with the Illuminating Engineering Society of North America (IESNA) recommended lighting levels or the local

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts AmbiStar SmartMate Standard T5HO PureVOLT 1 Lighting s Atlas -11 ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts Fluorescent allasts - - High-efficiency

More information

50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW

50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW 50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW Part #: WAL-SL-5-LED-12.3 Page: 1 The Larson Electronics WAL-SL-5-LED-12.3 Work Area Lighting LED String Light

More information

Performance and Efficiency

Performance and Efficiency Electronic Fluorescent Quick Guide 347V Applications Fluorescent Solutions Performance and Efficiency Electronic Fluorescent Ballasts for 347V Applications Quick Guide Contents Electronic Fluorescent Ballasts

More information

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware 14W Linear 2' LED Light - 1750 Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware Part #: WDL-24-1L-SS-2X5FT Page: 1 Made in Texas Providing 1,750 lumens of clean, crisp white light

More information

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW 100ft Temporary Construction String Light - Ten LED Work Lamps - 100 Watt LED Stringer - 12/3 SJTW Part #: WAL-SL-10-LED-12.3 Page: 1 The Larson Electronics WAL-SL-10-LED-12.3 Work Area Lighting LED String

More information

Prescriptive Lighting Rebate Application

Prescriptive Lighting Rebate Application 2017 Commercial Rebate Program Prescriptive Lighting Rebate Application (Member Information Input Page) WrightHennepin Cooperative Electric Assn., P.O. Box 330, Rockford, MN 55373 Ph: 7634773000 Business

More information

High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens

High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens Part #: GAU-HB-160LED Page: 1 The Larson Electronics GAU-HB-160LED High Bay LED Light Fixture provides operators with a powerful and energy

More information

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2S40SC35I 2 F34T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2S40SC35I 2 F34T12 277V Electronic Ballast Philips Advance Catalog VEL2S40SC35I Manufacturer Philips Advance Description

More information

1992 Energy Policy Act A Pacific Energy Center Factsheet

1992 Energy Policy Act A Pacific Energy Center Factsheet 1992 Energy Policy Act A Pacific Energy Center Factsheet The Energy Policy Act of 1992 affected all users of electric lighting. In addition to instituting requirements for electric motors, utility distribution

More information

31 SERIES Modular area fixtures. Replaces: 1000W HID

31 SERIES Modular area fixtures. Replaces: 1000W HID Replaces: 1000W HID Product Life: 75,000 hours Optic Lens: Borosilicate Glass 31 SERIES Modular area fixtures Neptun's LED parking lot /area fixtures combine architectural form and versatility to make

More information

Lighting Tables for New Equipment 7/16/2008

Lighting Tables for New Equipment 7/16/2008 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1

More information

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * ) Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * ) Energy Trust offers cash incentives to help you implement approved energy efficient lighting measures. If

More information

LED HIBAYS COMING OF AGE. Stan Walerczyk, LC, CLEP, HCLP Lighting Wizards

LED HIBAYS COMING OF AGE. Stan Walerczyk, LC, CLEP, HCLP Lighting Wizards LED HIBAYS COMING OF AGE Stan Walerczyk, LC, CLEP, HCLP Lighting Wizards July 4, 2013 1 INTRODUCTION Until early this year, I considered LED high bays, which I call hibays, really only cost effective for

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic

More information

Linear Fluorescent Lighting. Energy-Saving Lighting Systems

Linear Fluorescent Lighting. Energy-Saving Lighting Systems Linear Fluorescent Lighting Energy-Saving Lighting Systems Saving money and energy is now an important factor for business owners. Howard s Linear Fluorescent Fixtures provide those money and energy saving

More information

Linear Replacement Lamps

Linear Replacement Lamps Linear Replacement Lamps PLEASE NOTE: DLC DEFINES ALL TUBE-STYLE LED PRODUCTS THAT USE THE LAMP HOLDERS (I.E. SOCKETS OR TOMBSTONES ) IN THE LUMINAIRE TO MECHANICALLY OR ELECTRICALLY CONNECT TO THE FIXTURE

More information

Alter QHE Lighting Systems

Alter QHE Lighting Systems Alter QHE Lighting Systems ALTER HIGH EFFICIENCY (QHE)... Introducing Alter High Efficiency, the new specification-grade high-output Alter Soft Lights system developed by Lightolier. Lighting professionals

More information

LEDlescent TM T8 Ballast-Free Lamps

LEDlescent TM T8 Ballast-Free Lamps www.sylvania.com LEDlescent TM T8 Ballast-Free Lamps 2 North American Market T8 LED Options Replacement Lamps (UL Type A) Internal Driver Line Voltage Lamps (UL Type B) Single Ended Internal Driver Line

More information

Prescriptive Rebate Program

Prescriptive Rebate Program Prescriptive Rebate Program Black Hills Power Commercial Installing energy-efficient technology is a smart way for Commercial and Industrial customers to lower energy bills. Energy-efficient equipment

More information

Fixture Spec Sheet HFB3 Series 4/15/2011

Fixture Spec Sheet HFB3 Series 4/15/2011 HIGH BAY FLUORESCENT FOUR LAMP DESCRIPTION HFB3 series high-bay fluorescent fixture is a great energy saving alternative to traditional HID high-bay fixtures. This fixture operates four lamps and as a

More information

Average Retail Electricity Costs in North Carolina

Average Retail Electricity Costs in North Carolina Cents per Kwh 11 Average Retail Electricity Costs in North Carolina 10 9 8 7 6 5 Electricity, Commercial Electricity, Industrial Electricity, Residential 4 1995 2000 2005 2010 2015 Year Source: EIA Lighting

More information

Fixture Spec Sheet HFA2 Series 4/15/2011

Fixture Spec Sheet HFA2 Series 4/15/2011 HIGH BAY FLUORESCENT FOUR LAMP DESCRIPTION Factory Installed Option J HFA2 series high-bay fluorescent fixture is a great energy saving alternative to traditional HID high-bay fixtures. This fixture operates

More information

Spiral T2 10,000 & 8,000 hours

Spiral T2 10,000 & 8,000 hours GE Lighting Spiral T2 10,000 & 8,000 hours Compact Fluorescent Lamps Integrated 8W, 12W, 15W, 20W and 23W for EU DATA SHEET information The T2 10,000 & 8,000 hours spiral lamps are one of the most popular

More information

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview DL2000 High Brightness 6 LED Downlight Module Overview Heatron s Innovation Series DL2000 recessed downlight module helps luminaire manufacturers expand their product lines and bring new LED fixtures to

More information

INSTANT START BALLASTS

INSTANT START BALLASTS ULTRAMAX INSTANT START BALLASTS GE Consumer & Industrial TRANSFORMING THE POWER OF LIGHT Take Energy Savings to the MAX with Take Energy Savings to the MAX with High Efficiency Electronic Ballasts NEW

More information

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design - 3 or 4 Lamp Curved Profile Design Description HFB3 series high-bay fluorescent fixture is a great energy saving alternative to traditional HID highbay fixtures. This fixture operates three or four lamps

More information

T his chapter provides data on lighting technologies, including

T his chapter provides data on lighting technologies, including T his chapter provides data on lighting technologies, including typical prices, suggested values for hours of lamp operation in various rooms, and a worksheet that you can use to analyze the costs of using

More information

FC12T9CW 32W T9 12" Cir-C-Line 60 Cri Cool White Fluor

FC12T9CW 32W T9 12 Cir-C-Line 60 Cri Cool White Fluor 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FC12T9CW 32W T9 12" Cir-C-Line 60 Cri Cool White Fluor G.E. Lighting (Lampblst) Catalog Number Manufacturer Weight per

More information

CRI INDUCTION LUMEN MAINTENANCE LONG-LASTING BENEFITS THE EVOLUTION OF LIGHTING

CRI INDUCTION LUMEN MAINTENANCE LONG-LASTING BENEFITS THE EVOLUTION OF LIGHTING Pemco Lighting Products is very pleased to be able to offer a wide variety of Induction lamp systems, as an option, in almost all fixtures we manufacture. The following information should help you determine

More information

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent 23W Dimmable LED Bulb - 4' T8 Lamp - 2875 Lumens - Double Ended- Replacement/Upgrade for Fluorescent Part #: LEDT8-48-D-X2 The Larson Electronics LEDT8-48-D-X2 23 watt T-series Dimmable LED tube lamp is

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic

More information

Nema Head We light your world

Nema Head We light your world Nema Head We light your world 03.15.18 THD 80 PF >.95 10kV Surge Protector + 5-40 C~50 C 35,000 Warranty YEAR LED Nema Head 44w/65w Advances in LED technology allow us to create

More information

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS 83 Mini-Lynx Sticks 86 Mini-Lynx Spirals 88 Power-Lynx 89 Mini-Lynx Classico 90 Mini-Lynx Compact GLS 91 Mini-Lynx Compact Ball 92 Mini-Lynx Candle 93 Mini-Lynx Globe 94 Mini-Lynx Reflectors 96 Mini-Lynx

More information

Symetrie LED Linear Lighting Solutions

Symetrie LED Linear Lighting Solutions LED Linear Lighting Solutions Workstations, Coves & Retail Displays What is Symetrie? The Future of LED Linear Lighting, Today Lighting Science believes that financial and environmental responsibility

More information

TUNABLE SPECTRUM/TUNABLE WHITE

TUNABLE SPECTRUM/TUNABLE WHITE ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT Tunable natural white light on the Planckian curve Very high CRI and R9 values throughout range from 1650K thru 4000K (variable warm) and 2700K thru 0K (variable

More information

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens Part #: EPL-HB-25LED-RT Page: 1 The Larson Electronics EPL-HB-25LED-RT Explosion Proof High Bay light

More information

TUNABLE SPECTRUM/TUNABLE WHITE

TUNABLE SPECTRUM/TUNABLE WHITE ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT Tunable natural white light on the Planckian curve Very high CRI and R9 values throughout range from 1650K thru 4000K (variable warm) and 2700K thru 0K (variable

More information

Expanding PIER Partnerships: New Concepts for Development and Demonstration Task 2 National Guard Audit and Recommendations

Expanding PIER Partnerships: New Concepts for Development and Demonstration Task 2 National Guard Audit and Recommendations PROJECT REPORT Expanding PIER Partnerships: New Concepts for Development and Demonstration Task 2 National Guard Audit and Recommendations PROJECT DATE Californidfsdfsdfsdfa PREPARED FOR: Ken Krich Research

More information

A Designers Fountain Brand. We make Lighting Choices Simple. Commercial LED Lighting

A Designers Fountain Brand. We make Lighting Choices Simple. Commercial LED Lighting A Designers Fountain Brand We make Lighting Choices Simple Commercial LED Lighting With over 30 years in the lighting industry, DF ProPlus joins the prestigious family of Designers Fountain brands, offering

More information

20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2

20W LED Strip Light for Hazardous Location Lighting - 24 Surface Mount Bar - Class 1 Division 2 20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2 Part #: HAL-24-16W-LED Page: 1 Buy American Compliant The Larson Electronics HAL-24-16W-LED is a low profile

More information

new equipment & construction

new equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: 1. This application is for new high efficiency lighting fixtures, systems and controls. 2. Cutsheets/specifications including

More information

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B 150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B Part #: HBLP-REMG-1MLED-B-PND Page: 1 Made in Texas The Larson Electronics HBLP-REMG-1MLED-B-PND LED

More information

EDGE EX3B-WW 3 Suspended Bidirectional Linear Wall Wash

EDGE EX3B-WW 3 Suspended Bidirectional Linear Wall Wash Project Name Date Type 5-3/8 (136.5mm) EDGE EX3B-WW 3 7/16 (11.1m) 3-1/2 (88.9mm) 11/16 (17.5m) Key Features 6063-T5 Extruded aluminum housing Extruded aluminum module with miro reflector for perfect wall

More information

Recessed. EvoKit LED Retrofit Kits Gen 3

Recessed. EvoKit LED Retrofit Kits Gen 3 Project: Recessed Location: Cat.No: Type: Lamps: Qty: EvoKit LED Retrofit Kits Gen 3 2'x2' Notes: Philips EvoKit LED Retrofit Kit is an energy efficient LED alternative to traditional linear fluorescent

More information

RZT2S54 Electr DMMG Ballast

RZT2S54 Electr DMMG Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RZT2S54 Electr DMMG Ballast Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning 156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning Part #: EPL-360-3XLP24-LED-V2-100 Page: 1 Made in Texas The EPL-360-3XLP24-LED-V2-100 Portable Explosion

More information

150W Explosion Proof LED Portable Suspended Light - J-Hook Mount - 17,500 Lumens - C1D2 / C2D1

150W Explosion Proof LED Portable Suspended Light - J-Hook Mount - 17,500 Lumens - C1D2 / C2D1 150W Explosion Proof LED Portable Suspended Light - J-Hook Mount - 17,500 Lumens - C1D2 / C2D1 Part #: EPLC2-JHM-150LED-RT-100-EPP The EPLC2-JHM-150LED-RT-100-EPP from Larson Electronics is an Explosion

More information

400W High Intensity LED Light - 54,000 Lumens V AC - Bar Clamp/Trunnion Mount - Outdoor

400W High Intensity LED Light - 54,000 Lumens V AC - Bar Clamp/Trunnion Mount - Outdoor 400W High Intensity LED Light - 54,000 Lumens - 347-480V AC - Bar Clamp/Trunnion Mount - Outdoor Part #: GAU-LTL-400W-LED-480V-BC Page: 1 The GAU-LTL-400W-LED-480V-BC from Larson Electronics is a High

More information

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs The sustainable choice Optanium high-efficiency ballasts for today s T8 lighting needs A renewed focus on energy Across the country today, businesses are taking a much closer look at ways to conserve energy

More information

A Home Depot Company. Quality Lighting for Every Facility

A Home Depot Company. Quality Lighting for Every Facility A Home Depot Company Quality Lighting for Every Facility supplyworks.com Traditional Lighting: CFL SATCO SPIRAL COMPACT T2 Mini 13W 120V 82 CRI SATCO SPIRAL COMPACT T2 Mini 82 CRI Voltage Wattage Kelvin

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT One fixture converts nearly any manufacturers incandescent, CFL or H.I.D. fixtures with a rough-in inner diameter of 7-5 /8 to 8-1 /8 diameter to high efficiency

More information

COVE C CV N - - Architectural Cove Mount. Key Features CRI, CCT & OUTPUT LENGTH 1 MOUNTING VOLTAGE DRIVER CIRCUITING _ N

COVE C CV N - - Architectural Cove Mount. Key Features CRI, CCT & OUTPUT LENGTH 1 MOUNTING VOLTAGE DRIVER CIRCUITING _ N Project Name Date Type 2-13/16 2-9/16 3-15/16 Key Features Toolless 3 position adjustable head Integral Driver Wiring Quick Connection for rows 5-year limited warranty covers LED, driver and fixture UL

More information

Highbay Fluorescent - Six Lamp Flat Profile Design

Highbay Fluorescent - Six Lamp Flat Profile Design - Six Lamp Flat Profile Design Description HFA series high-bay fluorescent fixture is a great energy saving alternative to traditional HID highbay fixtures. This fixture operates six lamps and as a standard

More information

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug 25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug Part #: EXHL-SFC-LE1-50C-1227-EPP Page: 1 Made in Texas The EXHL-SFC-LE1-50C-1227-EPP from Larson Electronics is an

More information