MARUSON TECHNOLOGY. Uninterruptible Power Supply.

Size: px
Start display at page:

Download "MARUSON TECHNOLOGY. Uninterruptible Power Supply."

Transcription

1 MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: FAX: Copyright 2016 All Rights Reserved. Maruson is a registered trademark of Maruson Technology (U.S Trademark Register No. 3,150,957). All other trademarks are the property of their respective owners. Maruson reserves the right to modify product information or specifications without previous notice. Not all products have these regulatory certificate. Battery backup time is based on a basic PC or half load and varies with equipment, configuration, battery age, temperature, etc. V

2 COMPANY INTRODUCTION Maruson Technology Corporation (MTC) was established in 2003 with ISO 9001:2008 certification and trademark registered in the U.S.A. (Reg. No. 3,150,957). We design, manufacture, distribute and service power protection equipment including: uninterruptible power supply (UPS), automatic voltage regulator (AVR), power distribution units (PDU), and power inverters, which are employed across various sectors such as home, office, networking, datacenter, commercial, industrial, medical, etc. Our headquarters locate in Los Angeles, California, U.S.A. with additional office and factory in Taiwan and China to better service our customers globally. The Maruson team applies over 25 years of professionalism and knowledge in power solution industry to innovate continuously our product line, offer superior quality products and provide excellent customer service. Our motto, "Power solutions for all your needs", along with our unique and high quality standards are what our customers know us by. Choosing Maruson can help you find the right product for your applications and market demand. We also show how to maximize their productivity, provide professional after-sales service, and a variety of marketing programs to our distributors. When you need clean, reliable, power products for your equipment choose Maruson to fulfill your needs. TABLE OF CONTENTS LINE INTERACTIVE UPS Surveillance UPS Series 3 Power UPS Series 4 Power Office Series 5 Micro UPS Series 6 PowerPro UPS Series 7 SmartNet Series 8 SmartNet RT Series 9 ON-LINE UPS Ultima RT Series (1-10K) Ultima W Series (1-10K) Ultima Plus Series (6-10K) 14 Tacoma HV Series (1-3K) 15 Tacoma Series (6-20K) Ultima 31 Series (10-30K) 18 Ultima 33 Series (10-20K) 19 UltimaPro 33 Series (30-200K) ElementKin 33 Series (10-120K, Low Transformer Type) ElementAce 33 Series (10-200K, Low Industrial Grade) AUTOMATIC VOLTAGE REGULATOR Micro AVR Series (Relay Type) 26 Digital AVR Series (Toroidal Transformer Type) 27 Digital Plus AVR Series (Servo-Motor Type) 28 Mega 33 AVR Series (Servo-Motor Type, 3 Phases) 29 INVERTER UPS Security UPS Series (Option NC / NO Dry Contact & 12 VDC Port) 30 Power Home & Smart Home Series 31 Power Guard Inverter Series (Optional 50A PWM Solar Charger) 32 Smart Guard UPS Series (Toroidal Transformer Type) 33 Smart Power Inverter Series (Built In PWM Solar Charger) 34 Smart Solar Inverter Series (Built In PWM or MPPT Solar Charger) 35 Smart Grid Inverter Series (Built In PWM or MPPT With AVR) 36 MODULAR 3 PHASE ON LINE UPS Matrix SX33 HV10K Modular UPS (10 ~ 90 KVA) (Phase 1 In / 1 Out or 3 In / 1 Out Available) Matrix PX33 HV10 / 15 / 20K Modular UPS (10 ~ 400 KVA) Matrix RX33 HV25 / 30K Modular UPS (25 ~ 900 KVA) Brochure available upon request or at PDU Basic / Surged / Metered / Monitored / Switch / ATS / MBS PDU Series Brochure available upon request or at Authorized Distributor By: l i n e U P S 2 〡 Register Online O n 2 Year Warranty BEST MARUSON TECHNOLOGY CORP.BEST Power Protection

3 Surveillance UPS Series CCTV Power Distribution And UPS For Cameras And DVR / NVR 12 VDC / 24 VAC battery power backup for CCTV cameras Two boost one buck AVR with wide input operation voltage and stable output voltage 12 ~ 13 VDC adjustable output voltage to enhance video quality for long-distance cameras installation 9 / 18 ports overload protection (fuse optional) Batteries are hot swappable (cameras, DVR, & monitors are always on) Multi-LED display for AC / DC power supply and UPS status 2 Amp fuse or PTC (breaker) power protection Two AC outlet (NEMA 5-15R or IEC) with battery backup and surge protection for DVR and monitor AC power failure and cameras DC power failure notification through DVR / NVR or alarm system SUR-809 / 1218 / 1518UPS Built-in maintenance bypass switch Security key lock (Optional) Surveillance Systems DVR / NVR Equipment 12 VDC / 24 VAC Cameras Monitoring Systems SURVEILLANCE UPS SPECIFICATION MODEL SUR-809UPS SUR-1218UPS SUR-1518UPS Capacity 500 VA / 250 W 700 VA / 360 W 700 VA / 360 W Nominal 110 / 120 VAC or 220 / 230 / 240 VAC, 50 / 60 Hz (auto sensing) Input Range 80 ~ 145 VAC or 154 ~ 280 VAC (12 VDC / CCTV) DC (Programmable) 12 ~ 13 VDC (manually select 12,12.5,13 VDC) Watts 120 W 168 W Port 9 Ports (10 Amps) 14 Ports (14 Amps) 18 Ports (14 Amps) (24 VAC / CCTV) Watts None 100 W None Port None 4 Ports None (AC UPS ) Output Range 110 / 120 VAC ±10% or 220 / 230 / 240 VAC ±10% Outlets (Battery Backup) NEMA 5-15R or IEC x 1 (DVR / NVR), NEMA 5-15R or IEC x 1 (LCD monitor) Waveform (Battery Mode) Simulated sine wave (not included) Battery Capacity 7 Ah x 1 (7 Ah X 2 option) 7 Ah x 2 (9 Ah X 2 option) Backup Time (Basic DVR / Camera) 35 ~ 50 minutes 55 ~ 75 minutes 60 ~ 80 minutes Recharge Time < 6 hours to 90% capacity < 12 hours to 90% capacity < 12 hours to 90% capacity INDICATOR LED For UPS UPS status, battery mode, fault LED For Camera 7 x Green LED (DC 1 Amp) 2 x Amber LED (DC 2 Amp) 10 x Green LED (12 VDC 1 Amp) 4 x Amber LED (12 VDC 2 Amp) 4 x Amber LED (24 VAC 1 Amp) 14 x Green LED (DC 1 Amp) 4 x Amber LED (DC 2 Amp) Dimension (H x W x D) (mm / in) 102 x x 343 / 4.0 x 12.8x 13.5 Net Weight (kg / lb) 10 / / / 24.0 Power Solutions for All Your Needs 〡 3

4 Power UPS Series Line Interactive UPS With Compact Design 500 VA ~ 2200 VA line interactive UPS Microprocessor controlled for high reliability Advanced Battery Management (ABM) to increase battery longevity, performance, and reliability POW-1100A(S) / 1600AS / 2200AS Personal Computers P.O.S POW-500A / 700A / 900A Network Devices Alarm & Phone Systems Automatic voltage regulation (AVR) for wide input peration voltage and stable output voltage (for 500 ~ 2200 VA models) USB communications interface with power management software (AS models only) Auto restart while AC is recovering Overload, over discharge, and overcharge protection DC cold start function Off-mode charging Generator compatible (Optional) MODEL POW-500A POW-700A POW-900A POW-1100A(S) POW-1600AS POW-2200AS Capacity 500 VA / 250 W 700 VA / 360 W 900 VA / 480 W 1100 VA / 600 W 1600 VA / 900 W 2200 VA / 1200 W 110 / 120 VAC or 220 / 230 / 240 VAC Range 81 ~ 142 VAC or 162 ~ 284 VAC 81 ~ 145 VAC or 162 ~ 290 VAC 50 / 60 Hz (auto sensing) 110 / 120 VAC or 220 / 230 / 240 VAC 50 / 60 Hz Regulation (Battery Mode) ±10% Regulation (Battery Mode) ±1 Hz Output Waveform (Battery Mode) Simulated sine wave Battery Type & Number 12 V / 4.5 Ah x 1 12 V / 7 Ah x 1 12 V / 9 Ah x 1 12 V / 7 Ah x 2 12 V / 9 Ah x 2 12 V / 9 Ah x 2 Backup Time (Basic PC) Up to 18 minutes Up to 30 minutes Up to 40 minutes Up to 60 minutes Up to 85 minutes Up to 90 minutes Recharge Time 4 hours to 90% capacity 4 ~ 6 hours to 90% capacity 2 ~ 6ms (typical) INDICATOR AC Mode Green lighting Green lighting Battery Mode Green flashing Yellow flashing Fault N / A Red lighting PROTECTION TEL / Fax / Network Surge Protection N / A RJ-11 / 45 combo port Full Protection Overload, over discharge, and overcharge protection USB Port N / A Optional Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Dimension (D x W x H) (mm / in) 279 x 101 x 142 / 11.0 x 4.0 x x 130 x 182 / 12.6 x 5.1 x 7.2 Weight (kg / lb) 3.6 / / / / / / 〡 POWER LINE INTERACTIVE UPS SPECIFICATION

5 Power Office Series Line Interactive UPS With USB Charger Socket type POF-800 / 1000CSA POF-800 / 1000AU 800 VA ~ 1000 VA line interactive UPS 3 LEDs indicates UPS statuses, including normal, charging, back-up, battery low, fault, and overload Advanced battery management to increase battery longevity, performance and reliability Two boost and one buck automatic voltage regulator for high and low voltage DC cold start function for greater mobility Auto restart while AC is recovering 2 USB charging ports for USB devices RJ-11 / 45 combo telephone / fax / network line protection port Off-mode charging USB communication port with power management software to control & monitor UPS status (CSA models) Coaxial surge protection (Optional for CSA models) POF-800 / 1000U(S)A PC / Gaming Computers Surveillance & Security P.O.S. A / V & Home Theater POWER OFFICE LINE INTERACTIVE UPS SPECIFICATION MODEL POF-800AU POF-1000AU POF-800CSA POF-1000CSA Capacity 800 VA / 400 W 1000 VA / 500 W 800 VA / 400 W 1000 VA / 500 W 220 / 230 / 240 VAC Range -30% ~ +25% 50 / 60 Hz (auto sensing) 220 / 230 / 240 VAC Regulation (Battery Mode) ±10% 50 / 60 Hz Regulation (Battery Mode) ±1 Hz Waveform (Battery Mode) Simulated sine wave Typical 2 ~ 6ms (typical) Outlets 6 UK or 6 Schuko or 6 Australia (3 backup&surge + 3 surge only) or 9 Thailand (5 backup&surge + 4 surge only) Battery Type & Quantity 12 V / 7 Ah x 1 12 V / 9 Ah x 1 12 V / 7 Ah x 1 12 V / 9 Ah x 1 Backup Time (Basic PC) Up to 20 minutes Up to 30 minutes Up to 20 minutes Up to 30 minutes Typical Recharge Time < 5 Hours to 90% capacity PROTECTION Full Protection Over discharge protection & short circuit protection Tel / Fax / Network Suppression RJ-11 / 45 combo port Lighting & Surge Protection 175 Joules 480 Joules Coaxial Protection N / A Optional USB Charging Interface (2 Ports) 5 VDC / 2.1Amp (max.) charge current Monitoring Software N / A Communication software for windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10 Dimension (D x W x H) (mm / in) 290 x 94 x 170 / 11.4 x 3.7 x 6.7 Net Weight (kg / lb) 5 / / / / 13.0 Power Solutions for All Your Needs 〡 5

6 Micro UPS Series Line Interactive UPS With High Reliability Design Multiple LEDs indicates UPS statuses, including normal, charging, back-up, battery low, fault, and overload MIC-1100 / 1600 / 2200A(S) MIC-500 / 700 / 900A(S) Two boost and one buck AVR to stabilize input voltage Advanced battery management increases longevity, performance, and reliabillty Automatic restart of UPS while connected to AC power recovering DC cold start & off-mode charging function USB communications interface with power management software (AS models only) Friendly battery door design for easy batteries replacement (1100 VA ~ 2200 VA) 140 ~ 295 VAC wide input voltage range version (Optional for 220 V / W models) Green power function for energy saving (Optional) Desktop PCs Surveillance & Security P.O.S. Telephone Equipment MICRO LINE INTERACTIVE UPS SPECIFICATION MODEL MIC-500A MIC-700A(S) MIC-900A(S) MIC-1100A(S) MIC-1600A(S) MIC A(S) Capacity 500 VA / 250 W 700 VA / 360 W 900 VA / 480 W 1100 VA / 600 W 1600 VA / 900 W 2200 VA / 1200 W 110 / 115 / 120 VAC or 220 / 230 / 240 VAC Range 80 ~ 145 VAC or 154 ~ 280 VAC standard (Optional 140 ~ 295 VAC wide range version for 220 / 230 / 240 VAC models) 50 / 60 Hz (auto sensing) 110 / 115 / 120 VAC or 220 / 230 / 240 VAC 50 / 60 Hz Regulation (Battery Mode) ±10% Regulation (Battery Mode) ±1 Hz Waveform (Battery Mode) Simulated sine wave Battery Type & Number 12 V / 4.5 Ah x 1 12 V / 7 Ah x 1 12 V / 9 Ah x 1 12 V / 7 Ah x 2 12 V / 9 Ah x 2 12 V / 9 Ah x 2 Backup Time (Basic PC) Up to 18 minutes Up to 30 minutes Up to 40 minutes Up to 60 minutes Up to 85 minutes Up to 90 minutes Charging 13.7 VDC ±2% 13.7 VDC ±2% 13.7 VDC ±2% 27.4 VDC ±2% 27.4 VDC ±2% 27.4 VDC ±2% Recharge Time 5 hours to 90% after complete discharge TRANSFER TIME Typical < 6ms (typical) PROTECTION AC Surge Protection 175 Joules Phone / Fax / Network Surge Protection N / A RJ-11 (1 in & 1 out) RJ-11 / 45 (1 in & 1 out) Optional USB Port (AS Model) N / A Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Dimension (D x W x H) (mm / in) x 100 x 141 / 12.4 x 3.9 x x 135 x 208 / 13.5 x 5.3 x 8.2 Weight (kg / lb) 3.5 / / / / / / 〡

7 PowerPro UPS Series Line Interactive UPS With Power Management Solution Advanced battery management increases longevity, performance, and reliability PRO-1100 / 1600 / 2200LCD PRO-450 / 650 / 850LCD Two boost and one buck AVR to stabilize input voltage LCD displays UPS status, including voltage, load, and battery statuses Automatic restart of UPS while AC power recovering Off-mode charging function USB communications interface with power management software Friendly battery door design for easy batteries replacement (1100 VA ~ 2200 VA) DC cold start function 140 VAC ~ 295 VAC wide input voltage range version (Optional for 220 V / W models) Green power function for energy saving (Optional) Desktop PCs Small Server P.O.S. Gaming Computer POWERPRO LINE INTERACTIVE UPS SPECIFICATION MODEL PRO-450LCD PRO-650LCD PRO-850LCD PRO-1100LCD PRO-1600LCD PRO-2200LCD Capacity 450 VA / 250 W 650 VA / 360 W 850 VA / 480 W 1100 VA / 600 W 1600 VA / 900 W 2200 VA / 1200 W 110 / 115 / 120 VAC or 220 / 230 / 240 VAC Range 80 ~ 145 VAC or 154 ~ 280 VAC standard (Optional 140 ~ 295 VAC wide range version for 220 / 230 / 240 VAC models) 50 / 60 Hz (auto sensing) 110 / 115 / 120 VAC or 220 / 230 / 240 VAC 50 / 60 Hz Regulation (Battery Mode) ±10% Regulation (Battery Mode) ±1 Hz Waveform (Battery Mode) Simulated sine wave Battery Type & Number 12 V / 4.5 Ah x 1 12 V / 7 Ah x 1 12 V / 9 Ah x 1 12 V / 7 Ah x 2 12 V / 9 Ah x 2 Backup Time (Basic PC) Up to 18 minutes Up to 30 minutes Up to 40 minutes Up to 60 minutes Up to 85 minutes Up to 90 minutes Charging 13.7 VDC ±2% 13.7 VDC ±2% 13.7 VDC ±2% 27.4 VDC ±2% 27.4 VDC ±2% 27.4 VDC ±2% Recharge Time 5 Hours to 90% after complete discharge INDICATOR Display LCD displays UPS status, including voltage, load, and battery statuses TRANSFER TIME Typical < 6ms (typical) PROTECTION AC Surge Protection 320 Joules 480 Joules Phone / Fax / Network Surge Protection RJ-11 (1 in & 1 out) RJ-11 / 45 combo port (1 in & 1 out) Dimension (D x W x H) (mm / in) x 100 x 141 / 12.4 x 3.9 x x 135 x 208 / 13.5 x 5.3 x 8.2 Weight (kg / lb) 3.5 / / / / / / 25.1 Power Solutions for All Your Needs 〡 7

8 SmartNet Series Line Interactive UPS With Pure Sine Wave Output 750 VA ~ 2000 VA true sine wave UPS Built-in smart charger (6 hours to 90% charged) Charging ability at low input voltage (2 times more powerful than others) NET-1500 / 2000LCD NET-750 / 1000LCD Smart microprocessor control guarantees high reliability Boost and buck AVR for voltage stabilization Off-mode auto charging Cold start function (DC power on) Perfect power protection for servers, point-of-sale and work stations RJ-11 / 45 internet & network protection Built-in USB & RS-232 communication port Support external SNMP adapter for remote monitoring Midsize Servers ATM Machines Telecom & Networking Slot Machine SMARTNET LINE INTERACTIVE UPS SPECIFICATION MODEL NET-750LCD NET-1000LCD NET-1500LCD NET-2000LCD Capacity 750 VA / 480 W 1000 VA / 700 W 1500 VA / 1050 W 2000 VA / 1400 W 110 / 120 VAC or 220 / 230 / 240 VAC Range 81 ~ 145 VAC / 162 ~ 290 VAC 50 / 60 Hz (auto sensing) 110 / 120 VAC or 220 / 230 / 240 VAC AC Regulation (Battery Mode) ±10% 50 / 60 Hz Regulation (Battery Mode) ±1 Hz Waveform (Battery Mode) Pure sine wave TRANSFER TIME Typical 2 ~ 6ms Battery Type 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah 12 V / 10 Ah Battery Number Backup Time Up to 40 minutes Up to 60 minutes Up to 85 minutes Up to 90 minutes Typical Recharge Time 6 hours recover to 90% capacity INDICATOR LCD Display AC mode, battery mode, load level, battery level, input voltage, output voltage, overload, fault, and low battery PROTECTION Full Protection Overload, over discharge and overcharge protection USB & RS-232 Port Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Dimension (D x W x H) (mm / in) 350 x 146 x 160 / 13.8 x 5.7 x x 146 x 205 / 15.6 x 5.7 x 8.1 Net Weight (kg / lb) 6.8 / / / / 〡

9 SmartNet RT Series Line Interactive Rack / Tower Pure Sine Wave UPS NET-800 / 1500 / 2500RT NET-1100 / 2000 / 3000(L)RT Microprocessor-based line interactive design Pure sine wave output User-friendly and easy-shift LCD display Built-in boost and buck AVR to stabilize output voltage Output power factor 0.9 and 3:1 crest ratio Hot-swappable battery design Programmable power management outlets ECO operation for energy saving Emergency Power Off Function (EPO) Built-in USB & RS-232 communication port Long run (L) models available USB communication port with power management software and monitor UPS status Intelligent slot allows SNMP card (Optional) for remote power management Server Rooms Office Equipment Telecom Station Surveillance & Security SMARTNET RT LINE INTERACTIVE UPS SPECIFICATION MODEL NET-800RT NET-1100 (L) RT NET-1500RT NET-2000 (L) RT NET-2500RT NET-3000 (L) RT Capacity 800 VA / 720 W 1100 VA / 990 W 1500 VA / 1350 W 2000 VA / 1800 W 2500 VA / 2250 W 3000 VA / 2700 W 110 / 115 / 120 / 127 VAC or 208 / 220 / 230 / 240 VAC, 50 / 60 Hz (auto-sensing) Range 81 ~ 152 VAC or 162 ~ 290 VAC 110 / 115 / 120 / 127 VAC or 208 / 220 / 230 / 240 VAC Regulation (Battery Mode) ±1.5% (before low battery alarm) Harmonic Distortion 2% 100% linear load / 5% 100% non-linear load (before low battery alarm) 2 ~ 6ms (Typical) EFFICIENCY Battery Mode 88% 90% Type & Number 12 V / 7 Ah x 2 12 V / 9 Ah x 2 12 V / 7 Ah x 4 12 V / 9 Ah x 4 12 V / 7 Ah x 6 12 V / 9 Ah x 6 Standard Charging Current (max.) 1.5 A Model Charging 27.4 VDC ±1% 54.8 VDC ±1% 82.1 VDC ±1% Typical Recharge Time 4 hours recover to 90% capacity Long Run (L) Model Charging Current (max.) N / A 1 A / 2 A / 4 A / 6 A / 8 A N / A 1 A / 2 A / 4 A / 6 A / 8 A N / A 1 A / 2 A / 4 A / 6 A / 8 A INDICATOR LCD Display AC mode, battery mode, load level, battery level, input & output voltages, overload, fault, and low battery PROTECTION Full Protection Overload, over discharge, and overcharge protection Smart RS-232 / USB Port Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Standard Model Dimension (D x W x H) (mm / in) 410 x 438 x 88 / 16.1 x 17.2 x x 438 x 88 / 20.1 x 17.2 x x 438 x 88 / 24.8 x 17.2 x 3.5 Net Weight (kg / lb) 12.9 / / / / / / 64.6 Long Run (L) Model Dimension (D x W x H) (mm / in) N / A 410 x 438 x 88 / 16.1 x 17.2 x 3.5 N / A 410 x 438 x 88 / 16.1 x 17.2 x 3.5 Net Weight (kg / lb) N / A 9 / 19.8 N / A 10.8 / 23.8 N / A N / A 510 x 438 x 88 / 20.1 x 17.2 x LV 410 x 438 x 88 / 16.1 x 17.2 x HV 13.9 / 30.6@LV 11.9 / 26.2@HV Power Solutions for All Your Needs 〡 9

10 Ultima RT Series Double Conversion Online Rack / Tower UPS ULT-1 / 2 / 3K(L)RT ULT-6 / 10KLRT ULT-1 / 2 / 3K(L)RT ULT-6 / 10KRT Server Rooms Office Equipment Telecom & Networking Surveillance System 10 〡 ULTIMA RT ON-LINE UPS SPECIFICATION MODEL ULT-1KRT ULT-1KLRT ULT-1.5KRT ULT-1.5KLRT ULT-2KRT ULT-2KLRT ULT-3KRT ULT-3KLRT Capacity 1000 VA / 900 W 1500 VA / 1350 W 2000 VA / 1800 W 3000 VA / 2700 W Nominal 200 / 208 / 220 / 230 / 240 VAC Range 110 ~ 300 VAC ±5% Range 40 ~ 70 Hz Power Factor nominal voltage (100% load) Output 200 / 208 / 220 / 230 / 240 VAC Current Crest Ratio 3:1 (max.) Harmonic Distortion 2% THD (linear load) Transfer Time Line mode < - > Battery mode Inverter to Bypass Zero 4ms (typical) EFFICIENCY AC Mode 90% 91% Battery Mode 88% 89% 88% 90% ECO Mode 97% Battery Type 12 V / 9 Ah Depending on 12 V / 9 Ah Depending on 12 V / 9 Ah Depending on 12 V / 9 Ah Depending on Battery Numbers 2 The capacity of 3 The capacity of 4 The capacity of 6 The capacity of Typical Recharge Time 4 Hours recover to external batteries 4 Hours recover to external batteries 4 Hours recover to external batteries 4 Hours recover to external batteries 90% capacity 90% capacity 90% capacity 90% capacity Charging Current (max.) 1.5 A 1 A / 2 A / 4 A / 8 A 1.5 A 1 A / 2 A / 4 A / 8 A 1.5 A 1 A / 2 A / 4 A / 8 A 1.5 A 1 A / 2 A / 4 A / 8 A Charging 27.4 VDC ±1% 41.1 VDC ±1% 54.8 VDC ±1% 82.1 VDC ±1% INDICATOR LCD Panel Load level, battery level, AC mode, battery mode, bypass mode, and fault indicator Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser 410 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 410 x 438 x 88 / 630 x 438 x 88 / 510 x 438 x 88 / Dimension (2U) (D x W x H) (mm / in) 16.1 x 17.2 x x 17.2 x x 17.2 x x 17.2 x x 17.2 x x 17.2 x 3.5 Net Weight (kg / lb) 11.6 / 6.4 / 14.5 / 6.5 / 19.5 / 6.5 / 27.4 / 10.5 /

11 True double-conversion pure sine wave online UPS 0.9 Output power factor DSP control technology (6 KVA ~ 10 KVA models) ECO and advanced ECO mode for energy saving Easy-shift LCD display for rack / tower models Programmable power management outlets (1 KVA ~ 3 KVA models) 50 / 60 Hz frequency converter mode Emergency Power Off (EPO) function Intelligent slot allows SNMP card (Optional) for remote power management N + X parallel redundancy up to 3 units for 6 KVA & 10 KVA models (Optional) External PDU / maintenance bypass switch (Optional) Extendable runtime feature ("L" model) ULTIMA RT ON-LINE UPS SPECIFICATION MODEL ULT-6K(L)RT ULT-6K(L)RTD ULT-10K(L)RT ULT-10K(L)RTD Capacity 6000 VA / 5400 W VA / 9000 W Nominal 200 / 208 / 220 / 230 / 240 VAC Range 176 ~ 300 VAC at 100% load; 110 ~ 175 VAC de-rating up to 50% load Range 46 ~ 54 Hz or 56 ~ 64 Hz Power Factor Nominal voltage (100% load) Output 200 / 208 / 220 / 230 / 240 VAC (104 / 110 / 115 / 120 VAC) x / 208 / 220 / 230 / 240 VAC (104 / 110 / 115 / 120 VAC) x 2 Current Crest Ratio 3:1 (max.) Harmonic Distortion Transfer Time Line mode < - > Battery mode Inverter< - > Bypass 2% THD (linear load), 4% THD (non-linear load) 3.5% THD (linear load), 7% THD (non-linear load) 2% THD (linear load), 4% THD (non-linear load) Zero Zero 3.5% THD (linear load), 7% THD (non-linear load) EFFICIENCY Line Mode 91% 85% 91% 85% Battery Mode 88% 82% 88% 82% ECO Mode 96% 87% 96% 87% Standard Model Long Run (L) Model Nominal INDICATOR LCD Panel Smart RS-232 / USB Optional SNMP 240 VDC Battery Type 12 V / 7 Ah 12 V / 9 Ah Numbers 20 (18 ~ 20 pcs Programmable) 20 (18 ~ 20 pcs Programmable) Typical Recharge Time 7 Hours recover to 90% capacity 9 Hours recover to 90% capacity Charging Current (max.) Float Charging Battery Type And Numbers Charging Current (max.) Float Charging Dimension (3U) (D x W x H) (mm / in) Net Weight (kg / lb) UPS Unit / Battery Bank : 606 x 438 x 133 / 23.9 x 17.2 x 5.2 UPS Unit: 20 / 44.1 Battery bank: 58 / A 273 VDC (based on battery numbers at 20 pcs) Depending on applications 4.0 A 273 VDC (based on battery numbers at 20 pcs) UPS status, load level, battery level, input / output voltage, discharge timer, and fault conditions Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Power management from SNMP manager and web browser UPS Unit / Battery Bank / ISO Bank 606 x 438 x 133 / 23.9 x 17.2 x 5.2 UPS Unit: 20 / 44.1 Battery Bank: 58 / ISO Bank: 61 / EXTERNAL MAINTENANCE BYPASS SWITCH MBS-610RM UPS Unit:686 x 438 x 133 / 27.0 x 17.2 x 5.2, Battery Bank: 606 x 438 x 133 / 23.9 x 17.2 x 5.2 UPS Unit: 23.5 / 51.8 Battery Bank: 65 / MBS-123RM UPS Unit / ISO Bank: 686 x 438 x 133 / 27.0 x 17.2 x 5.2, Battery Bank: 606 x 438 x 133 / 23.9 x 17.2 x 5.2 UPS Unit: 23.5 / 51.8 Battery Bank: 65 / ISO Bank: 90 / Power Solutions for All Your Needs 〡 11

12 Ultima W Series Double Conversion Online Tower UPS ACCESSORY ITEM MBS-123TW True double-conversion technology Microprocessor control optimizes reliability Input power factor correction Pure sine wave output Wide input voltage (110 ~ 300 VAC) Converter mode available ECO mode for energy saving Generator compatible Charger capacity expandable up to 6 A for long runtime (L) models Comprehensive display allows easy monitoring and access of UPS status ULT-W3K(L) ULT-W2K(L) ULT-W1K(L) Smart SNMP (card option) simultaneously works well with USB or RS-232 together External PDU / maintenance bypass switch (Optional) Server Rooms Office Equipment Telecom & Networking Security System ULTIMA W ON-LINE UPS SPECIFICATION MODEL ULT-W1K(L) ULT-W2K(L) ULT-W3K(L) Capacity 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 200 / 208 / 220 / 230 / 240 VAC Range 160 ~ 280 VAC at 100% load; 110 ~ 300 VAC at 50% load Range 40 ~ 70 Hz 200 / 208 / 220 / 230 / 240 VAC Range 47 ~ 53 Hz or 57 ~ 63 Hz (synchronized range) Current Crest Ratio 3:1 Harmonic Distortion 3% THD (linear load) / 6% THD (non-linear load) Zero (AC mode to battery mode), typical 4ms (inverter to bypass) EFFICIENCY To AC Mode 88% 90% To Battery Mode 83% 87% 88% Type & Number 12 V / 9 Ah x 2 12 V / 9 Ah x 4 12 V / 9 Ah x 6 Standard Model Typical Recharge Time 4 hours recover to 90% capacity Charging Current (Max.) 1.0 A Charging 27.4 VDC ±1% 54.7 VDC ±1% 82.1 VDC ±1% Long Run (L) Model Charging Current (Max.) 1.0 A / 2.0 A / 4.0 A / 6.0 A LCD Display Load level, battery level, AC mode, battery mode, bypass mode, and fault indicators Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Standard Model Dimension (D x W x H) (mm / in) 282 x 145 x 220 / 11.1 x 5.7 x x 145 x 220 / 15.6 x 5.7 x x 190 x 318 / 16.6 x 7.5 x 12.5 Net Weight (kg / lb) 9.8 / / / 60.9 Long Run (L) Model Dimension (D x W x H) (mm / in) 282 x 145 x 220 / 11.1 x 5.7 x x 145 x 220 / 15.6 x 5.7 x 8.7 Net Weight (kg / lb) 4.1 / / / 〡

13 Ultima W Series Double Conversion Online Tower UPS ULT-W6KL / ULT-W10KL ULT-W6K / ULT-W10K True double-conversion technology Microprocessor control optimizes reliability Input power factor correction Pure sine wave output Wide input voltage (110 ~ 300 VAC) Converter mode available Generator compatible Emergency power off (EPO) function Charger capacity expandable up to 6 A for long runtime (L) models Smart SNMP (card option) simultaneously works well with USB or RS-232 together Comprehensive display allows easy monitoring and access of UPS status External PDU / maintenance bypass switch (Optional) Server Rooms Professional Workstation Telecom & Networking Office Equipment ULTIMA W ON-LINE UPS SPECIFICATION MODEL ULT-W6K ULT-W6KL(D) ULT-W10K ULT-W10KL(D) Capacity 6000 VA / 4800 W VA / 8000 W Nominal 208 / 220 / 230 / 240 VAC Range 176 ~ 300 VAC at 100% load; 110 ~ 300 VAC at 50% load Range 46 ~ 54 Hz or 56 ~ 64 Hz 208 / 220 / 230 / 240 VAC & 120 VAC available in (D) model Range 46 ~ 54 Hz or 56 ~ 64 Hz (synchronized range) Current Crest Ratio 3:1 (max.) Harmonic Distortion w / o ISO 3% THD (linear load) / 5% THD (non-linear load) Zero EFFICIENCY Line Mode w / o ISO 92% 93% Battery Mode w / o ISO 90% 91% Battery Type 7 Ah (9 Ah optional) Depending on applications 9 Ah Depending on applications Numbers 16 pcs 16 ~ 20 pcs (Programmable) 16 pcs (20 pcs optional) 16 ~ 20 pcs (Programmable) Typical Recharge Time 8 hours recover to 90% capacity Depending on the capacity of external batteries 8 hours recover to 90% capacity Depending on the capacity of external batteries Charging Current Default:1.0 A ±10% 1 / 2 / 4 / 6 16 pcs Default:1.0 A ±10% 1 / 2 / 4 / 6 pcs Float Charging VDC ±1% 273 VDC ±1% (Based on 20 pcs batteries) VDC ±1% 273 VDC ±1% (Based on 20 pcs batteries) INDICATOR LCD Panel Load level, battery level, AC mode, battery mode, bypass mode, and fault indicators Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Dimension (D x W x H) (mm / in) w / o ISO 369 x 190 x 688 / 14.5 x 7.5 x x 190 x 318 / 14.5 x 7.5 x x 190 x 688 / 17.4 x 7.5 x x 190 x 318 / 17.4 x 7.5 x 12.5 UPS Net Weight (kg / lb) w / o ISO 61 / / / / 35.3 Power Solutions for All Your Needs 〡 13

14 Ultima Plus Series Double Conversion Online UPS With DSP Technology ULT-P6KL / P10KL Server Rooms Automation Equipment ULT-P6K / P10K Telecom & Networking Office Equipment Online double conversion technology DSP technology guarantees high performance Pure sine wave output 1.0 output power factor High efficiency up to 94% 3-Stage extendable charging design for optimized battery performance Generator compatible Wide input voltage range (110 ~ 300 VAC) 0.99 active input power factor correction 50 / 60 Hz frequency converter mode Emergency power off function (EPO) Build-in maintenance bypass switch Optional N + X parallel redundancy Optional OVCD ( over voltage cut-off device) protection 14 〡 ULTIMA PLUS ON-LINE UPS SPECIFICATION MODEL ULT-P6K ULT-P6KL ULT-P10K ULT-P10KL Capacity 6000 VA / 6000 W VA / W Nominal 208 / 220 / 230 / 240 VAC Range 176 ~ 300 VAC at 100% load ; 110 ~ 300 VAC at 60% load Range 46 ~ 54 Hz or 56 ~ 64 Hz Power Factor 100% load 208 / 220 / 230 / 240 VAC Current Crest Ratio 3:1(max.) Harmonic Distortion 1% THD (linear load) 1% THD (linear load) 1% THD (linear load) 1% THD (linear load) Zero EFFICIENCY Line Mode 94% Battery Mode 91% Battery Type 12 V / 7 Ah (9 Ah optional) Depending on applications 12 V / 9 Ah Depending on applications Numbers 16 pcs 16 ~ 20 (Programmable) 16 pcs 16 ~ 20 (Programmable) Typical Recharge Time 8 hours recover to 90% capacity Depending on ext. Batt. Capacity 8 hours recover to 90% capacity Depending on ext. Batt. Capacity Charging Current Default: 1.0 A Max.: 2.0 A Float Charging VDC ±1% Max. 4.0 A 273 VDC ±1% (Based on 20 pcs batteries) Default: 1.0 A Max.: 2.0 A VDC ±1% Max. 4.0 A 273 VDC ±1% (Based on 20 pcs batteries) INDICATOR LCD Panel UPS status, load level, battery level, input / output voltage, discharge timer, and fault conditions Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Dimension (D x W x H) (mm / in) 369 x 190 x 688 / 14.5 x 7.5 x x 190 x 318 / 14.5 x 7.5 x x 190 x 688 / 17.4 x 7.5 x x 190 x 318 / 17.4 x 7.5 x 12.5 Net Weight (kg / lb) 54 / / / / 35.3

15 Tacoma HV Series Double Conversion Online UPS With DSP Technology TAC-HV2 / 3K(L) TAC-HV1K(L) True double-conversion technology 0.9 output power factor High efficiency mode (ECO) DSP controlled for advance maintenance Pure sine wave output converter mode Wide input voltage (110 ~ 300 V) Input THDi < 5% and Output THDv < 3% Output voltage regulation < 2% Fan speed controller based on UPS load Extendable runtime feature ("L" model) USB ports for power management software SNMP card (Optional) Emergency Power Off function (EPO) ATM Server Rooms Telecom & Networking Office Equipment TACOMA HV ON-LINE UPS SPECIFICATION MODEL TAC-HV1K TAC-HV1KL TAC-HV2K TAC-HV2KL TAC-HV3K TAC-HV3KL Capacity 1000 VA / 900 W 2000 VA / 1800 W 3000 VA / 2700 W Range 110 ~ 300 VAC Range 45 ~ 55 Hz / 54 ~ 66 Hz THDi < 5% with full load Power Factor nominal voltage (100% load) 200 / 208 / 220 / 230 / 240 VAC Current Crest Ratio 3:1 Harmonic Distortion < 3% THD (linear load); < 5% THD (non-linear load) EFFICIENCY Line Mode > 88% BAT Mode > 85% ECO Mode > 93% > 94% Number of Batteries Battery Type 12 V / 7 Ah Depending on 12 V / 7 Ah Depending on 12 V / 7 Ah Depending on the capacity of the capacity of the capacity of Backup Time > 5 minutes external batteries > 9 minutes external batteries > 5 minutes external batteries Recharge Time 5 hours to 90% 5 hours to 90% 5 hours to 90% Charging Current 1 A 8 A 1 A 8 A (12 A optional) 1 A 8 A (12 A optional) TRANSFER TIME BAT < -- > LINE 0ms INV < -- > BYPASS < 4ms INDICATOR LCD Display Load / battery / input / output / operating mode information USB Software Supports windows family, Linux, Sun Solaris, IBM, Aix, Compaq True64, SGIIRIX, FreeBSD, HP-UX, MAC External Slot External type of SNMP or AS400 card EPO Emergency power off Dimension (W x H x D) (mm / in) / 5.7 x 8.7 x / 7.6 x 13.7 x 18.1 Net Weight (kg / lb) 13 / / / / / / 28.7 Power Solutions for All Your Needs 〡 15

16 Tacoma Series 1 / 1 or 3 / 1 Input Phase Selectable Online UPS 6KVA ~ 20KVA DSP, true double conversion UPS DSP control technology greatly reduces harmonic TAC-10K31 / 20K31 TAC-6 / 10K(L) distortion in non-linear loads without manual intervention for advanced maintenance. True double conversion UPS provides clean, high quality power, ideal for sensitive applications. High efficiency mode (ECO) Energy-saving, Efficiency Corrective Optimizer(ECO) mode, allows efficiency up to 98% (TAC-10K31 & TAC-20K31) and 96% (TAC-6K(L) & TAC-10K(L)) for more cost effective UPS system. converter mode Input / Output accepts different frequency. Server Rooms Office Equipment Telecom & Networking Automation Equipment 16 〡 TACOMA ON-LINE UPS SPECIFICATION MODEL TAC-6K TAC-6KL TAC-10K TAC-10KL Capacity 6 KVA / 5.4 KW 6 KVA / 5.4 KW 10 KVA / 9 KW 10 KVA / 9 KW Input Range 110 ~ 276 VAC Range 45 ~ 55 Hz / 54 ~ 66 Hz Phase Single phase with ground Power Factor > 100% load 208 / 220 / 230 / 240 VAC Current Crest Ratio 3:1 Harmonic Distortion linear load / non-linear load Output Waveform Pure sine wave Parallel Up to 4 EFFICIENCY Line Mode > full load and battery fully charged BAT Mode > full load and 12 VDC / battery Number of Internal Batteries Per Set 20 pcs 20 pcs Battery Type 12 VDC / 7.2 Ah Depend on the capacity 12 VDC / 9 Ah Depend on the capacity Backup Time > 5 minutes of external batteries > 5 minutes of external batteries Recharge Time 5 hours charge to 90% 5 hours charge to 90% Charging Current (max) 1.2 A 4.0 A 1.2 A 4.0 A Rated Battery 240 VDC TRANSFER TIME LINE < -- > BAT 0ms INV < -- > BYPASS 0ms INDICATORS LCD Panel Load level / battery voltage / battery mode / AC mode / bypass mode information RS-232 / USB Software Software supports windows family / Linux / Sun Solaris / IBM / Aix / CompaqTrue64 / SGIIRIX / FreeBSD / HP-UX / MAC Intelligent Slot SNMP / AS400 / relay card Dimension (W x H x D) 260 x 708 x 550 / 10.2 x 27.9 x 21.7 Net Weight (kg / lb) 90 / / / / 90.4

17 Input THDi < 5% and output THDv < 2% Low Total Harmonic Distortion (THD) for low electrical distortion to provide pure power for sensitive applications and other critical applications. Fan speed controller based on UPS load Fan automatically turns on based on UPS load and adjusts speed based on load. N + X Parallel redundancy Connect up to 4 units for parallel redundancy. Extendable runtime feature Long back-up time models available for extended run time and larger charger for critical equipment. SNMP slot & card (Optional) SNMP card allows easy monitoring of multiple UPS control and monitoring through RJ-45 network connection for remote management, warning alarms, historic data log, and password security protection. Emergency Power Off (EPO) EPO safety feature allows immediate power down of UPS and equipment in case of emergency to protect connected equipment. AC input phase selectable: 1 / 1 or 3 / 1 (TAC-10K31 & TAC-20K31 models) Selectable input phase for high flexibility in single phase and three-phase setups. RS-232 and USB ports for power management software Easily monitor the current status of the UPS with WinPower software for control and monitor multiple UPS. Output voltage regulation < 1% Provides quality, stable output power. 0.9 High output power factor The 0.9 output power factor provides higher performance and efficiency to critical applications. TACOMA ON-LINE UPS SPECIFICATION MODEL TAC-10K31 TAC-20K31 Capacity 10 KVA / 9 KW 20 KVA / 18 KW Input Range 110 ~ 276 VAC depends on load level for single phase input / 190 ~ 478 VAC depends on load level for three phase input Range 45 ~ 55 Hz / 54 ~ 66 Hz Phase Three phase with ground (combo) Power Factor > 0.99@ 100% load 200 / 208 / 220 / 230 / 240 VAC Current Crest Ratio 3:1 Harmonic Distortion linear load / non-linear load Output Waveform Pure sine wave Parallel Up to 4 EFFICIENCY Line Mode > full load and battery full charged BAT Mode > full load and 12 VDC / battery Number of Internal Batteries Per Set 24 pcs x 1 group 24 pcs x 2 groups Battery Type 12 VDC / 9 Ah 12 VDC / 9 Ah Backup Time (Full Load) > 5 minutes > 5 minutes Recharge Time 5 hours charge to 90% Charging Current (Max) 2 A (Expandable) 4 A (Expandable) Rated Battery 288 VDC TRANSFER TIME LINE < -- > BAT 0ms INV < -- > BYPASS 0ms INDICATOR LCD Load level / battery voltage / battery mode / AC mode / bypass mode information RS-232 / USB Software supports windows family / Linux / Sun Solaris / IBM / Aix / CompaqTrue64 / SGIIRIX / FreeBSD / HP-UX / MAC Intelligent Slot SNMP / AS400 / relay card Dimension (W x H x D) (mm / in) 350 x 890 x 650 / 13.8 x 35 x 25.6 Net Weight (kg / lb) 115 / / Power Solutions for All Your Needs 〡 17

18 Ultima 31 Series 1 / 1 or 3 / 1 Input Phase Selectable Online UPS ULT-30K31 ULT-30K(L)31 ULT-15 / 20K31 ULT-10K(L) & 15 / 20KL31 True double-conversion pure sine wave output Output power factor 0.9 DSP technology guarantees high performance Active power factor correction in all phases Built-in phase auto adapt function simplifies wire installation 50 / 60 Hz frequency converter mode ECO mode operation for energy saving Programmable power management outlets Emergency power off function (EPO) Generator compatible SNMP + USB + RS-232 multiple communications AC input / output phase can be set to 1 / 1 by factory Optional N + X parallel redundancy Data Centers Automation Equipment Telecom & Networking Office Equipment 18 〡 ULTIMA 31 ON-LINE UPS SPECIFICATION MODEL ULT-10K(L)31 ULT-15K(L)31 ULT-20K(L)31 ULT-30K(L)31 Phase 3-phase in / 1-phase out Capacity VA / 9000 W VA / W VA / W VA / W Nominal 3 x 400 VAC (3Ph+N) Range 305 ~ 478 VAC (3-phase) at 100% load; 190 ~ 520 VAC (3-phase) at 50% load Range 46 ~ 54 Hz or 56 ~ 64 Hz Power Factor 100% load THDi < 100% load Output 208 / 220 / 230 / 240 VAC Current Crest Ratio 3:1 (max.) Harmonic Distortion 2% THD (linear load), 5% THD (Non-linear load) Zero EFFICIENCY AC Mode 91.5% 91.8% 92.1% Battery Mode 87% 88% 89% Battery Type 12 V / 9 Ah Standard Model Numbers 20 pcs (18 ~ 20 pcs adjustable) 20 pcs (18 ~ 20 pcs adjustable) x 2 strings Typical Recharge Time 9 hours recover to 90% capacity 20 pcs (18 ~ 20 pcs adjustable) x 3 strings Charging Current (max.) 1 A 2 A 4 A Charging 273 VDC ±1% (Based on 20 pcs batteries) Long Run (L) Model Charging Current (max.) 4 A 8 A 12 A INDICATORS LCD Display UPS status, load level, battery level, input / output voltage, discharge timer, and fault conditions Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Standard Model Long Run (L) Model Dimension (D x W x H) (mm / in) 592 x 250 x 576 / 23.3 x 9.8 x x 250 x 826 / 32.1 x 9.8 x x 300 x 1000 / 32.1 x 11.8 x 39.4 Net Weight (kg / lb) 83 / / / 516 Dimension 592 x 250 x 576 / 592 x 250 x 576 / 815 x 250 x 826 / (D x W x H) (mm / in) 23.3 x 9.8 x x 9.8 x x 9.8 x 32.5 Net Weight (kg / lb) 28 / / / 141.1

19 Ultima 33 Series 3 Phase UPS With Double Conversion Technology ULT-10 / 15 / 20KL33 ULT-10 / 15 / 20K33 DSP technology guarantees high performance 0.9 output power factor Active power factor correction in all phases Pure sine wave output 50 / 60 Hz frequency converter mode ECO mode operation for energy saving Emergency power off function (EPO) Generator compatible SNMP + USB + RS-232 multiple communications Adjustable battery numbers Build-in maintenance bypass switch Optional N + X parallel redundancy Optional isolation transformer offers full isolation and complete common mode noise rejection Small Data Centers Automation Equipment Telecom & Networking Factory Equipment ULTIMA 33 ON-LINE UPS SPECIFICATION MODEL ULT-10K(L)33 ULT-15K(L)33 ULT-20K(L)33 Phase 3 Phase input / 3 phase output Capacity VA / 9000 W VA / W VA / W Nominal 3 x 400 VAC (3Ph+N) Input Range 305 ~ 478 VAC (3-phase) at 100% load / 190 ~ 520 VAC (3-phase) at 50% load Range 46 ~ 54 Hz or 56 ~ 64 Hz Power Factor 100% load Output 3 x 400 VAC (3Ph+N) Current Crest Ratio 3:1 (max.) Harmonic Distortion 2% THD (linear load); 5% THD (non-linear load) Zero EFFICIENCY AC Mode 90.5% 91.5% Battery Mode 87% 88% Battery Type 12 V / 9 Ah Standard Model Numbers Typical Recharge Time 16 pcs 16 pcs x 2 strings 9 hours recover to 90% capacity Charging Current (max.) 1 A Charging VDC ±1% Long Run (L) Model Charging Current (max.) 4 A / 273 VDC ±1% (based on 20 pcs batteries) INDICATORS LCD Display UPS status, load level, battery level, input / output voltage, discharge timer, and fault conditions Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Standard Model Long Run (L) Model Dimension (D x W x H) (mm / in) 592 x 250 x 826 / 23.3 x 9.8 x 32.5 Net Weight (kg / lb) 96 / / Dimension (D x W x H) (mm / in) 592 x 250 x 576 / 23.3 x 9.8 x 23.0 Net Weight (kg / lb) 32 / / 77.2 Power Solutions for All Your Needs 〡 19

20 UltimaPro 33 Series 3 Phase UPS With Double Conversion Technology True double-conversion technology True double conversion UPS provides clean, high quality power, ideal for sensitive applications. When the utility is lost accidentally, the UPS system will use the power from battery to output without interruption. DSP control guarantees high performance DSP control technology greatly reduces harmonic distortion in non-linear loads without manual intervention for advanced maintenance. Active power factor correction in all phases By cancelling input current harmonics, the harmful effects of harmonic injection into the power network is eliminated. Lower power losses would result in reduced consumption and lower operation and maintenance costs. ULT-P200KL33 ULT-P160KL33 ULT-P100KL33 ULT-P120KL33 ULT-P30K33 ULT-P40K33 ULT-P60KL33 ULT-P80KL33 ULT-P30KL33 ULT-P40KL33 Medium / Large Data Center Management & Monitoring Center Telecom & Networking Business Equipment 20 〡 ULTIMAPRO 33 ON-LINE UPS SPECIFICATION MODEL ULT-P30K(L)33 ULT-P40K(L)33 ULT-P60KL33 ULT-P80KL33 Phase 3-Phase in / 3-phase out Capacity 30 KVA / 27 KW 40 KVA / 36 KW 60 KVA / 54 KW 80 KVA / 72 KW Nominal 3 x 380 / 400 / 415 VAC (3 Ph + N) Range 190 ~ 520 VAC 50% Load; 305 ~ 478 VAC 100% Load Range 46 ~ 54 Hz or 56 ~ 64 Hz Power Factor 100% Load THDi ~ 130 VAC or 205 ~ input THDU < 1.6% and full linear load condition with battery fully charged Output (Pure Sine Wave) 3 x 360 / 380 / 400 / 415 VAC (3 Ph+N) AC Regulation (Batt. Mode) ±1% Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz Current Crest Ratio 3:1 Harmonic Distortion 2% THD (Linear Load), 5% THD (Non-linear Load) AC Mode <=> Batt. mode & Inverter <=> bypass Overload AC Mode 100 ~ 110% for 10 min, 110 ~ 130% for 1 min, > 130% for 1 second Battery Mode 100 ~ 110% for 30 seconds, 110 ~ 130% for 10 seconds, > 130% for 1 second EFFICIENCY AC Mode 95% ECO Mode 98% Battery Mode 92% Battery Type 12 V / 7 Ah 12 V / 9 Ah Standard Model Long-run Model Numbers (2 x 16) pcs x 2 strings (2 x 16) pcs x 2 strings Typical Recharge Time 9 hours recover to 90% capacity Charging Current (Max.) 2 A Charging ±218.4 VDC (13.65 VDC x 32 pcs) Battery Type Depending on the capacity of external batteries Numbers 2 x (16 ~ 20) pcs (Adjustable) Charging Current (Max.) 4 A 8 A Charging ±13.65 V x N (N=16 ~ 20) INDICATORS LCD Display UPS status, Load level, Battery level, Input / Output voltage, Discharge timer, and Fault Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Standard Dimension (D x W x H) (mm / in) 815 x 300 x 1000 / 32.1 x 11.8 x 39.4 N / A Model Net Weight (kg / lb) 205 / / Long Run Dimension (D x W x H) (mm / in) 592 x 250 x 576 / 23.3 x 9.8 x x 360 x 900 / 31.1 x 14.2 x 35.4 Model Net Weight (kg / lb) 43 / / / N / A

21 0.9 high output power factor The 0.9 output power factor provides higher performance and efficiency to critical applications. ECO mode operation for energy saving (ECO) Energy-saving, Efficiency Corrective Optimizer (ECO) mode, allows efficiency up to 98% for more cost effective UPS system. Emergency power off function (EPO) EPO safety feature allows immediate power down of UPS and equipment in case of emergency to protect connected equipment. 50 / 60 Hz frequency converter mode Input / Output accepts different frequency 3-stage extendable charging design for optimized battery performance Adjustable battery numbers for long-run model Built-in Maintenance bypass function Optional parallel operation up to 3 units Connect up to 3 units for parallel redundancy. Extendable runtime feature long back-up time models available for extended run time and larger charger for critical equipment. Optional isolation transformer Optional 7" touch LCD panel SNMP + USB + RS-232 multiple communications The UPS is also built-in multiple communications including RS-232, USB and intelligent slot. With free download software, this UPS provides complete power solution of monitoring and controlling remotely. Generator compatible ULTIMAPRO 33 ON-LINE UPS SPECIFICATION MODEL ULT-P100KL33 ULT-P120KL33 ULT-P160KL33 ULT-P200KL33 Phase 3-Phase in / 3-phase out Capacity 100 KVA / 90 KW 120 KVA / 108 KW 160 KVA / 144 KW 200 KVA / 180 KW Nominal 3 x 380 / 400 / 415 VAC (3 Ph + N) Range 190 ~ 520 VAC 50% Load; 305 ~ 478 VAC 100% Load Range 46 ~ 54 Hz or 56 ~ 64 Hz Power Factor 100% Load THDi ~ 130 VAC or 205 ~ input THDU < 1.6% and full linear load condition with battery fully charged Output (Pure Sine Wave) 3 x 360 / 380 / 400 / 415 VAC (3 Ph+N) AC Regulation (Batt. Mode) ±1% Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz Current Crest Ratio 3:1 Harmonic Distortion 2% THD (Linear Load), 5% THD (Non-linear Load) AC Mode <=> Batt. mode & Inverter <=> bypass Overload AC Mode 100 ~ 110% for 10 min, 110 ~ 130% for 1 min, > 130% for 1 second Battery Mode 100 ~ 110% for 30 seconds, 110 ~ 130% for 10 seconds, > 130% for 1 second EFFICIENCY AC Mode 95% ECO Mode 98% Battery Mode 92% 93% Battery Type Standard Model Long-run Model Numbers Typical Recharge Time Charging Current (Max.) Charging Battery Type Numbers N / A Depending on the capacity of external batteries 2 x (16 ~ 20) pcs (Adjustable) Charging Current (Max.) 12 A 16 A Charging ±13.65 V x N (N=16 ~ 20) INDICATORS LCD Display UPS status, Load level, Battery level, Input / Output voltage, Discharge timer, and Fault Smart RS-232 / USB Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser Standard Dimension (D x W x H) (mm / in) N / A Model Net Weight (kg / lb) N / A Long Run Dimension (D x W x H) (mm / in) 850 x 550 x 1500 / 33.5 x 21.7 x x 550 x 1700 / 37.4 x 21.7 x x 650 x 2100 / 39.4 x 25.6 x 82.7 Model Net Weight (kg / lb) 150 / / / Power Solutions for All Your Needs 〡 21

22 ElementKin 33 Series 3 Phase Online UPS with Low Architecture Optional 7" touch LCD Online double-conversion This UPS series is a double conversion system with sine wave output. It supplies continuous, stable, clean power for commercial and industrial environments. When the utility is lost accidentally, the UPS system will use the power from battery to output without interruption. ELM-K120KHV ELM-K60 / 80 / 100KHV Factory Equipment Industrial Equipment ELM-K30 / ELM-20KHV 40KHV Telecom & Networking Data Center ELM-K10 / 15KHV ELEMENTKIN 33 ON-LINE UPS SPECIFICATION MODEL ELM-K10KHV ELM-K15KHV ELM-K20KHV ELM-K30KHV ELM-K40KHV Capacity 10 KVA / 8 KW 15 KVA / 12 KW 20 KVA / 16 KW 30 KVA / 24 KW 40 KVA / 32 KW Nominal 3 x 380 / 400 VAC (3 Ph+N) Acceptable Range 285 ~ 475 VAC 50 / 60 Hz ±10% INVERTER Nominal 3 x 380 / 400 VAC (3Ph + N) Precision Stationary: ±1%, Transitory: ±5% (load variations %) 50 / 60 Hz synchronised ±1% With mains absent ±0.1 Hz Max. Synchronisation Speed ±1 Hz / s Waveform Pure sine wave Total Harmonic Distortion (THDv) < 2% (Linear load); < 5% (non-linear load) Phase Displacement 120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load) Dynamic Recovery Time 3 cycles at 90% of the static value Admissible Overload 110% for 10min; 150% for 60sec; > 160% for 200ms Admissible Crest Factor 3:1 Admissible Power Factor 0.6 ~ 1 (inductive or capacitive) Imbalance 100% Unbalanced Load < 1% Current Limit High overload, short-circuit: RMS voltage limit; high crest-factor current: peak voltage limit STATIC BYPASS Type Solid state 3 x 380 / 400 VAC (3Ph + N) 50 / 60 Hz Activation Criterion Microprocessor control Zero Admissible Overload 150% for 1 hour; 180% for 30sec; > 200% for 200ms Transfer to Bypass Immediate, for overloads above 160% Retransfer Automatic after alarm clear MAINTENANCE BYPASS Type Without interruption 3 x 400V (3Ph + N) 50 / 60 Hz Overall Efficiency Line Mode 92% 90% 91% Battery Mode 93% & CHARGER Battery Type and Numbers 12 VDC x 32 pcs (29 ~ 32 pcs adjustable) Nominal Battery 384 VDC (Based on 32 pcs batteries) Charging Method CC / CV Charging Current Default 10 A, max. = Capacity / Battery Default 10 A, max. 40A Charging 432 VDC (Based on 32 pcs batteries) Dimensions, D x W x H (mm / in) 656 x 405 x 817 / 25.8 x 15.9 x x 405 x 941 / 25.8 x 15.9 x x 432 x 1159 / 32.3 x 17.0 x 45.6 Net Weight (Kg / lb) 118 / / / / / 〡

23 DSP technology guarantees high reliability with true galvanic isolation transformer design This system is applied an advanced digital controller to control the double conversion system, and with an isolated transformer at the output to protect the load and the UPS itself. Control designed to withstand all kinds of loads This UPS series uses low-frequency and true galvanic isolation circuit architecture applicable to all kinds of loads. Variety of communication options available The UPS is also built-in multiple communications including RS-232, RS-485, USB, EPO, Dry Contact and intelligent slot. With free download software, this UPS provides complete power solution of monitoring and controlling remotely. The details are listed as below: Adjustable battery numbers Intelligent battery management to prolong battery lifecycle Redundant fan design and independent ventilation enhance durable operation under harsh environment Suitable the wider operating environment Ambient temperature: 0 ~ +55 C Storage temperature: -15 ~ 60 C Relative humidity: 5 ~ 95% Altitude: If the UPS is installed within 1000m, the UPS power will not be de-rated. When the height is over 1000m, the output power will be de-rated by following the table: Altitude(m) Coefficient 100% 95% 91% 86% 82% 78% 74% 70% 67% Accept dual-mains input The line input and bypass input are separated routes in this UPS. Users can apply different power sourced into these two input routes and set up a dual-input system. Users also can connect the same power source to these two inputs. Once the utility fails, no Line input and bypass input is available at the same time. Then, it will transfer to battery mode. Parallel operation with up to 4 units (option) 7" touch LCD screen (option) ELEMENTKIN 33 ON-LINE UPS SPECIFICATION MODEL ELM-K60KHV ELM-K80KHV ELM-K100KHV ELM-K120KHV Capacity 60 KVA / 48 KW 80 KVA / 64 KW 100 KVA / 80 KW 120 KVA / 96 KW Nominal 3 x 380 / 400 VAC (3 Ph+N) Acceptable Range 285 ~ 475 VAC 50 / 60 Hz ±10% INVERTER Nominal 3 x 380 / 400 VAC (3Ph + N) Precision stationary: ±1%, transitory: ±5% (load variations %) 50 / 60 Hz synchronised ±1% with mains absent ±0.1 Hz Max. Synchronisation Speed ±1 Hz / s Waveform Pure sine wave Total Harmonic Distortion (THDv) < 2% (Linear load); < 5% (non-linear load) Phase Displacement 120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load) Dynamic Recovery Time 3 cycles at 90% of the static value Admissible Overload 110% for 10min; 150% for 60sec; > 160% for 200ms Admissible Crest Factor 3:1 Admissible Power Factor 0.6 ~ 1 (inductive or capacitive) Imbalance 100% Unbalanced Load < 1% Current Limit high overload, short-circuit: RMS voltage limit ; high crest-factor current: peak voltage limit STATIC BYPASS Type Solid state 3 x 380 / 400 VAC (3Ph + N) 50 / 60 Hz Activation Criterion Microprocessor control Zero Admissible Overload 150% for 1 hour; 180% for 30sec; > 200% for 200ms Transfer to Bypass Immediate, for overloads above 160% Retransfer Automatic after alarm clear MAINTENANCE BYPASS Type Without interruption 3 x 400 V (3Ph + N) 50 / 60 Hz Overall Efficiency Line Mode 92% Battery Mode 93% 93% & CHARGER Battery Type and Numbers 12 VDC x 32 pcs (29 ~ 32 pcs adjustable) Nominal Battery 384 VDC (Based on 32 pcs batteries) Charging Method CC / CV Charging Current Default 10 A, max. 40 A Charging 432 VDC (Based on 32 pcs batteries) Dimensions, D x W x H (mm / in) 975 x 554 x 1286 / 38.4 x 21.8 x x 635 x 1326 / 38.4 x 25.0 x 52.2 Net Weight (Kg / lb) 400 / / / / Power Solutions for All Your Needs 〡 23

24 ElementAce 33 Series 3 Phase UPS For Industrial Applications ELM-A100 / 120KHV Industrial Equipment Military application ELM-A10 / 15 / 20 / 30 / 40 / 60 / 80KHV Energy Industry Infrastructures ELM-A160 / 200KHV On-line double conversion UPS with DSP control ElementAce 33 applies online double conversion technology to effectively insulate against power line noise / spikes / transients disturbances and enables higher system load uptime. The DSP control provides solution with high performance. Strong electrical performance to prevent damage from top and bottom connections This UPS is designed to accept wide input voltage and frequency range to cope with the worst utility conditions. It's capable to support heavy duty equipment, production equipment and DCS (Distributed Control System) system. Variation types : 3 phase / 1 phase 220 VDC (10 KVA ~ 120 KVA) 3 phase / 1 phase 384 VDC (10 KVA ~ 120 KVA) 3 phase / 3 phase 384 VDC (10 KVA ~ 200 KVA) 3 phase / 3 phase 480 VDC (100 KVA ~ 800 KVA) 24 〡 ELEMENTACE 33 ON-LINE UPS 384 VDC SPECIFICATION MODEL ELM-A10KHV ELM-A15KHV ELM-A20KHV ELM-A30KHV ELM-A40KHV ELM-A60KHV Phase 3-phase in / 3-phase out Capacity 10 KVA / 8 KW 15 KVA / 12 KW 20 KVA / 16 KW 30 KVA / 24 KW 40 KVA / 32 KW 60 KVA / 48 KW Nominal 3 x 380 / 400 / 415 VAC (3Ph + N or 3Ph + N + G) Acceptable Range 304 ~ 456 VAC 50 Hz ±5 Hz (±10%) Nominal (Pure Sine Wave) 3 x 380 / 400 / 415 VAC (3Ph + N + G) Output Stability ±1% (steady state), ±5% (transient state) Stability 50 Hz ± 1 % Synchronization Range ±5 Hz (Equal to bypass working range) & slew rate 1 ~ 2 Hz / s Crest Factor 3:1 Total Harmonic Distortion (THDv) < 2% (linear load), < 4% (non-linear load) Dynamic in-rush Range 0%- > 100%- > 0% (R load) < ±5%: 20%- > 100%- > 20% (R load) < ±3% Dynamic Recovery Time (III Grade) 0 ~ 100% RCD load: < 60ms recover to 90% of nominal voltage Phase Displacement 120º ±1% (balanced load), 120º ± 2% (imbalances 50% of the load) 0ms Overload Capability 0 ~ 110% continuous running; 110 ~ 150% for 10min ~ 1min; > 160 % for 200ms Short-circuit Capability 60 ~ 100ms Transient Response Time < 5ms BYPASS Input Range 220 VAC ±25% Overload Capability 1.5In ~ 1.8In 1h ~ 30s SYSTEM Efficiency (At Linear Load) 90% 91% EPO Function Yes Standard IEC protection surge, IEC EMC / EMI, IEC safety & CHARGER Charger Type 6 pulse Rated Output 384 VDC Charger 395 ~ 435 VDC (adjustable) Charging Current (max.) 20 A 40 A Battery Type Support VRLA battery Battery Numbers 32 pcs (29 ~ 32 adjustable) Modbus RS-232/RS485 Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Dry Contacts 6 outputs and 2 inputs Optional SNMP Power management from SNMP manager and web browser IP Protection IP20 (default), IP21 / IP31 (option) Dimension (D x W x H) (mm / in) 800 x 800 x 1800 / 31.5 x 31.5 x 70.9 Net Weight (kg / lb) 350 / / / / / /

25 Facile battery configuration adapts different applications Battery numbers can be adjusted flexibly according to different power demands. High short-circuit and overload capabilities This UPS is built-in high short-circuit protection. Once short circuit occurs, this protection device will be activated. The load will stay protected and the UPS will remain intact. High overload protection supports 110% for 60 minutes and 125% for 10 minutes. Handy integration into existing electrical networks or generator ElementAce series is allowed for either top or bottom wiring connection depending on various environment condition. Besides, this UPS is fully compatible with generator. Parallel capability up to 4 units Up to 4 units in parallel can be operated without adding additional hardware, increasing system capacity as well as operation reliability for power redundancy. Admissibility dual-mains inputs ElementAce series is allowed to connect two separate power inputs to increase operation reliability. Screw less cabinet design and fully coating PCBAs to withstand harsh environment The outside cabinet is designed only with locks without any screws and all PCBAs are coated for anti-moisture, anti-electric leakage, anti-dust and anti-corrosion. Its robust design is suitable for high temperature, high humidity, dusty, salty and vibrated of harsh environment. Excellent ventilation design for effective heat dissipation Unique ventilation design allows heat flowing to top as natural convection. Therefore, the UPS cabinets can be added in parallel side by side for space-saving. Front access makes maintenance and replacement easily An important consideration has been given to allow generous access to the unit s electronic cards and power components. All the boards are accessible by front panel for easily maintenance and replacement. ELEMENTACE 33 ON-LINE UPS 384 VDC SPECIFICATION MODEL ELM-A80KHV ELM-A100KHV ELM-A120KHV ELM-A160KHV ELM-A200KHV Phase 3-phase in / 3-phase out Capacity 80 KVA / 64 KW 100 KVA / 80 KW 120 KVA / 96 KW 160 KVA / 128 KW 200 KVA / 160 KW Nominal 3 x 380 / 400 / 415 VAC (3Ph + N or 3Ph + N + G) Acceptable Range 304 ~ 456 VAC 50 Hz ±5 Hz (±10%) Nominal (Pure Sine Wave) 3 x 380 / 400 / 415 VAC (3Ph + N + G) Output Stability ±1% (steady state), ±5% (transient state) Stability 50 Hz ±1% Synchronization Range ±5 Hz (Equal to bypass working range) & slew rate 1 ~ 2Hz / s Crest Factor 3:1 Total Harmonic Distortion (THDv) < 2% (linear load), < 4% (non-linear load) Dynamic in-rush Range 0%- > 100%- > 0% (R load) < ±5%: 20%- > 100%- > 20% (R load) < ±3% Dynamic Recovery Time (III Grade) 0 ~ 100% RCD load: < 60ms recover to 90% of nominal voltage Phase Displacement 120º ±1% (balanced load), 120º ±2% (imbalances 50% of the load) 0ms Overload Capability 0 ~ 110% continuous running; 110 ~ 150% for 10 min ~ 1 min; > 160% for 200ms Short-circuit Capability 60 ~ 100ms Transient Response Time < 5ms BYPASS Input Range 220 VAC ±25% Overload Capability 1.5In ~ 1.8In 1h~30s SYSTEM Efficiency (At Linear Load) 92% 88% EPO Function Yes Standard IEC protection surge, IEC EMC / EMI, IEC safety & CHARGER Charger Type 6 pulse 6 pulse or 12 pulse Rated Output 384 VDC Charger 395 ~ 435 VDC (adjustable) Charging Current (max) 40A 50A Battery Type Support VRLA battery Battery Numbers 32 pcs (29 ~ 32 adjustable) Modbus RS-232/RS485 Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix and MAC Dry Contacts 6 outputs and 2 inputs Optional SNMP Power management from SNMP manager and web browser IP Protection IP20 (default), IP21 / IP31 (option) Dimension (D x W x H) (mm / in) 800 x 800 x 1800 / 31.5 x 31.5 x x 1200 x 1800 / 31.5 x 47.2 x x 1600 x 1800 / 31.5 x 63.0 x 70.9 Net Weight (kg / lb) 790 / / / / / Power Solutions for All Your Needs 〡 25

26 Micro AVR Series AVR For Stable Power Protection 800 VA ~ 5000 VA, two boost and one buck relay type AVR for voltage stabilization AVR-800 / 1200 / 2000 VA Home Application System Personal Computers AVR-3000 / 4000 / 5000LCD Network Peripherals Printers & Copiers Input voltage and output voltage LCD display (3000 ~ 5000 VA) 6 Outlets for 800 ~ 2000 VA & 8 outlets (3000 ~ 5000 VA) Resettable circuit breaker for overload protection Selectable delay time setting (2 / 10 / 30 seconds) (3000 ~ 5000 VA) Cable management (800 ~ 2000 VA) RJ-11 / 45 combo telephone / fax / network line protection port (3000 ~ 5000 VA) Optional coaxial cable line protection Optional USB charging ports (800 ~ 2000 VA) MICRO AVR SPECIFICATION MODEL AVR-800VA AVR-1200VA AVR-2000VA AVR-3000LCD AVR-4000LCD AVR-5000LCD Capacity 800 VA / 400 W 1200 VA / 600 W 2000 VA / 1000 W 3000 VA / 1500 W 4000 VA / 2000 W 5000 VA / 2500 W AC Nominal 220 / 230 / 240 VAC 120 / 220 VAC Input Range 161 ~ 288 VAC 95 ~ 150 VAC or 172 V ~ 276 VAC Phase 1 phase 2 wires 50 / 60 Hz (auto sensing) AC Nominal 220 / 230 / 240 VAC 120 / 220 VAC Output Range 207 ~ 253 VAC 108 ~ 129 VAC or VAC Phase 1 phase 2 wires 50 / 60 Hz DC Output Range 5 VDC (±2%) N / A OUTLETS Surge only 3 pcs N / A AVR + Surge Protection 3 pcs 8 pcs PROTECTION Surge Suppression N / A 240 Joules Network Surge Suppression RJ-11 / RJ-45 Overload Manual reset circuit switch Over Current Manual reset circuit switch Short Circuit Manual reset circuit switch LCD SCREEN Input Display N / A Showing input voltage Output Display N / A Showing output voltage after stabilized Dimension (D x W x H) (mm / in) 280 x 120 x 80 / 11 x 4.7 x x 150 x 250 / 6.2 x 5.9 x 9.8 Net Weight (kg / lb) 1.4 / / / / 11 6 / / 〡

27 Digital AVR Series AVR For Stable Power Protection C.R.G.O. TRANSFORMER DIG-1 / 1.5 / 2KVA CHASSIS VARIATION Desk top (DT type) DIG-3 / 5 / 8 / 10KVA DIG-15 / 20KVA Wall mount (WM type) 1KVA ~ 20KVA automatic voltage regulator Authentic zero-crossing technology catches real current zero-crossing Taylor-made C.R.G.O. toroidal transformer High efficiency, low loss, low rising temperature, and long lifespan High performance and high speed MCU control for lower power consumption and better efficiency Resettable circuit breaker for overload protection Full function, graphic LED display indicator for easy status reading Selectable delay time settings: 6 sec. delay for computers appliances, 180 sec. for home & motorized equipments Optional W Series for input range of 100 ~ VAC and 65 ~ VAC Chassis variation: Desk top DT type and wall mount WM type (optional) Office Equipment Factory Application Home Appliances Industrial DIGITAL AVR SPECIFICATION MODEL DIG-1KVA DIG-1.5KVA DIG-2KVA DIG-3KVA DIG-5KVA DIG-8KVA DIG-10KVA DIG-15KVA DIG-20KVA Capacity 1000 VA 1500 VA 2000 VA 3000 VA 5000 VA 8000 VA VA VA VA 98 ~ 142 VAC or 140 ~ 260 VAC 140 ~ 260 VAC 50 / 60 Hz (auto sensing) Phase Single phase 110 / 115 / 120 VAC or 220 / 230 / 240 VAC 220 / 230 / 240 VAC 50 / 60 Hz Phase Single phase Outlets Terminal block Efficiency 98% Precision ±8% ~ ±10% TRANSFORMER Transformer Taylor-made, C.R.G.O., toroidal transformer DISPLAY Digital Display Display indicates input load, output load, frequency, and load level PROTECTION Delay Time Setting Selectable between 6 / 180 seconds Overload Yes Over Current Yes High Temperature Yes High / Low Yes Short Circuit Yes Cooling Fan N / A Smart cooling Dimension (D x W x H) (mm / in) 237 x 146 x 170 / 9.3 x 5.7 x x 220 x 230 / 13.2 x 8.7 x x 220 x 230 / 13.8 x 8.7 x 9.1 Net Weight (@ 220 VAC) (kg / lb) 3.0 / / / / / / / / / 46.1 Net Weight (@ 120 VAC) (kg / lb) 3.5 / / / / / 19.8 N / A Power Solutions for All Your Needs 〡 27

28 Digital Plus AVR Series AVR For Stable Power Protection SERVO TYPE STABILIZER 3 KVA ~ 20 KVA automatic voltage regulator Hybird servo motor plus AVR for combined high precision without instant high voltage surge and fast response Authentic zero-crossing technology catches real current zero-crossing Taylor-made C.R.G.O. toroidal transformers High performance and high speed MCU control for lower power consumption and better efficiency High efficiency, low loss, low rising temperature, and long lifespan DIG-P3 / P5KVA DIG-P8 / P10KVA DIG-P15 / P20KVA Independent SMT processing technology Resettable circuit breaker for overload protection Full function, graphic LED display indicator for easy status reading Optional W Series for input range of 110 ~ VAC Office Equipment Factory Application Home Appliances Industrial DIGITAL PLUS AVR SPECIFICATION MODEL DIG-P3KVA DIG-P5KVA DIG-P8KVA DIG-P10KVA DIG-P15KVA DIG-P20KVA Capacity 3000 VA 5000 VA 8000 VA VA VA VA 130 ~ 270 VAC 50 / 60 Hz Phase Single phase 50 / 60 Hz (auto sensing) 220 VAC Outlets Terminal block Phase Single phase Efficiency 98% Precision ±1% ~ ±3% TRANSFORMER Transformer Taylor-made, C.R.G.O., toroidal transformer DISPLAY Digital Display Working and loading PROTECTION Delay Time Setting Yes, selectable between 6 / 180 seconds Overload Yes High Temperature Yes High / Low Yes Short Circuit Yes Cooling Fan Yes, smart cooling Dimension (D x W x H) (mm / in) 305 x 204 x 200 / 12.0 x 8.0 x x 220 x 250 / 14.0 x 8.7 x x 220 x 335 / 17.9 X 8.7x 8.7 x 13.2 Net Weight (kg / lb) 9.1 / / / / / / 〡

29 Mega 33 AVR Series Three Phase AVR For Stable Power Protection 9 KVA ~ 60 KVA three phase automatic voltage regulator Hybird servo motor plus AVR for combined high precision without instant high voltage surge and fast response Authentic zero-crossing technology catches real current zero-crossing Taylor-made C.R.G.O. toroidal transformer for compact size and efficiency High performance and high speed MCU control with accurate detection for lower power consumption and better efficiency High efficiency, low loss, low rising temperature, and long lifespan MGA-HV45 / 60K33 Resettable circuit breaker for overload protection MGA-HV9 / 15K33 Full function, graphic LED display indicator for easy status MGA-HV25 / 30K33 reading Optional W Series for input range of 3 phase 190 ~ 465 VAC (line to line) Factory & Office equipment Three-Phase Load Device Air Conditioning & Motor Industrial Equipment MEGA 33 AVR SPECIFICATION MODEL MGA-HV9K33 MGA-HV15K33 MGA-HV25K33 MGA-HV30K33 MGA-HV45K33 MGA-HV60K33 Capacity 9 KVA 15 KVA 25 KVA 30 KVA 45 KVA 60 KVA 225 ~ 465 VAC (3 phase+n+g) Inlet Terminal block 50 / 60 Hz (auto sensing) 380 VAC (3 phase+n+g) Outlet Terminal block Efficiency 98% Precision ±1% ~ ±3% TRANSFORMER Transformer Taylor-made, C.R.G.O. Toroidal transformer DISPLAY Digital Status Display Normal working / Time delay / Overheat / Unusual / Overload / Over voltage / Under voltage PROTECTION Delay Time Setting Yes, selectable between 6 / 180 seconds Overload Yes High Temperature Yes High / Low Yes Short Circuit Yes Cooling System Yes Dimension (D x W x H) (mm / in) x x 297 / 9.0 x 18.3 x x 590 x 420 / 13.8 x 23.2 x x 480 x / 15.1 x 18.9 x 25.3 Net Weight (kg / lb) 27.2 / / / / / / Power Solutions for All Your Needs 〡 29

30 Security UPS Series Line Interactive UPS With Long Runtime Availability 600 VA / 1 KVA / 2 KVA simulated sine wave output Wide input voltage range (140 ~ 300 VAC) Excellent microprocessor control guarantees high reliability Boost and buck AVR for voltage stabilization Selectable charging current Large charging current design for external big capacity battery application SEC-600AL SEC-1000 / 2000AL Advanced Battery Management (ABM) to increase battery longevity, performance, and reliability Over discharge and overcharge protection Auto restart while AC is recovering DC cold start function Overload and short circuit protection NC / NO x 3 sets dry contact communication ports (Optional) 12 VDC output port connect to an external buzzer (Optional) Alarm & Phone Systems Professional Workstations Surveillance & Security P.O.S. SECURITY LINE INTERACTIVE UPS SPECIFICATION MODEL SEC-600AL SEC-1000AL SEC-2000AL Capacity 600 VA / 360 W 1000 VA / 600 W 2000 VA / 1200 W 220 / 230 VAC Range 140 ~ 300 VAC Range 50 Hz / 60 Hz (Auto Sensing) Reg. (Battery Mode) ±10% Freq. Reg. (Battery Mode) 50 Hz ±1 Hz Typical 4 ~ 8ms Waveform (Battery Mode) Simulated sine wave Battery 12 VDC 24 VDC Floating Charging 13.7 VDC ±2% 27.4 VDC ±2% Max. Charging Current 2.5 A / 6 A / 10 A (Adjustable from manufacturer) 5 A / 10 A / 15 A / 20 A (Adjustable from manufacturer) PROTECTION Full Protection Overload, over discharge, and over charge protection INDICATOR Line Mode Green lighting Battery Mode Yellow flashing Fault Red lighting ALARM Low Battery Sounding every second Overload Sounding every 0.5 second Battery Replacement Alarm Sounding every 2 seconds Fault Continuously sounding Dimension (D x W x H) (mm / in) x 96.8 x / 14.1 x 3.8 x x 145 x 220 / 15.6 x 5.7 x 8.7 Net Weight (kg / lb) 5.8 / / / 〡

31 Power Home & Smart Home Series Long Runtime & High Performance Inverter POWER HOME 850 VA / 1.5 KVA simulated sine wave inverter Selectable input voltage range for home appliances and personal computers 12 VDC or 24 VDC available Selectable charging current Generators & Computer-related devices compatible Auto restart while AC is recovering Overload and short circuit protection Cold start function LED panel for status indicator SMART HOME 700 VA / 1.2 KVA pure sine wave inverter Selectable input voltage range for home appliances and personal computers Selectable charging current Generators & Computer-related devices compatible Auto restart while AC is recovering Overload and short circuit protection Smart battery charger design for optimized battery performance Cold start function UPS-850HL / 1500HL UPS-700SW / 1200SW Personal Computers Campus Home Appliances Portable AC TVs & Copiers Motorized Appliances Home & Office Appliances Portable AC POWER HOME & SMART HOME INVERTER SPECIFICATION SERIES POWER HOME SMART HOME MODEL UPS-850HL UPS-1500HL UPS-700SW UPS-1200SW CAPACITY 850 VA / 600 W 1500 VA / 1050 W 700 VA / 500 W 1200 VA / 840 W 120 / 230 VAC 230 VAC Range (Selectable) 90 ~ 145 VAC / 180 ~ 260 VAC (UPS mode), 50 ~ 160 VAC / 100 ~ 300 VAC (inverter mode) 50 / 60 Hz (auto sensing) 170 ~ 280 VAC (UPS mode), 90 ~ 280 VAC (inverter mode) Regulation (Battery Mode) 120 VAC ±10% or 230 VAC ±10% 230 VAC ± 5% 10ms (UPS mode), 20ms (inverter mode) Waveform (Battery Mode) Simulated sine wave Pure sine wave (Not Included) Battery 12 VDC 24 VDC 12 VDC Floating Charge 13.7 VDC ±2% 27.4 VDC ±2% 13.5 VDC ±2% Low Battery Alarm 10.2 VDC ±2% 20.4 VDC ±2% 11.5 VDC ±2% Shutdown 9.9 VDC ±2% 19.8 VDC ±2% 10.5 VDC ±2% Overcharge Protection 15.0 VDC ± 2% 30.0 VDC ± 2% 15.0 VDC ±2% Maximum Charge Current 10 A or 20 A (select Able) 10 A or 15 A (select Able) 10 A or 20 A (select Able) PROTECTION Full Protection Overload and short circuit protection INDICATORS AC Mode Green lighting Low Battery Yellow flashing LCD Indicates line mode, battery mode, load level, battery capacity, input voltage, output voltage, fault, and low battery Fault Red lighting Dimension (D x W x H) (mm/in) 289 x 290 x 127 / 11.4 x 11.4 x 5.0 Net Weight (w/o Battery) (kg/lb) 6.99 / / / / 10.6 Power Solutions for All Your Needs 〡 31

32 Power Guard Series Long Runtime & High Performance Inverter PWG-H1200(S) PWG-H2400(S) 1.2 KVA / 2.4 KVA off-grid inverter Built-in AVR for voltage regulation 12 VDC / 24 VDC available Simulated sine wave output Selectable charging current Auto restart while AC is recovering Overload, short circuit and reverse polarity protection Cold start function Wide input voltage range Smart charger design for optimized battery performance Internal 50 A PWM solar charger (Only for S models) Home Appliances Professional Workstations Surveillance & Security Business Store POWER GUARD INVERTER SPECIFICATION MODEL PWG-H1200(S) PWG-H2400(S) Capacity 1200 VA / 720 W 2400 VA / 1440 W 230 VAC Input Range 90 ~ 280 VAC Range 50 / 60 Hz (Auto sensing) Output voltage Regulation (Batt. Mode) 230 VAC ±10% Range (Batt. Mode) 50 / 60 Hz ±1 Hz 20ms typical Waveform (Battery Mode) Simulated sine wave Battery 12 VDC 24 VDC Acceptable Battery Type Rechargeable lead-acid and deep discharge battery Acceptable Input Range for Charger 90 ~ 280 VAC DC Start > 11 VDC > 22 VDC AC CHARGER Constant Current Charge 14.3 VDC ±2% 28.6 VDC ±2% Floating Charge 13.7 VDC ±2% 27.4 VDC ±2% Maximum Charge Current 10 A / 20 A (Selectable) SOLAR CHARGER FOR (S) MODELS Maximum PV Array Open Circuit 40 VDC 60 VDC Operating Range 15 ~ 18 VDC 30 ~ 32 VDC Maxmum Solar Charge Current 50 A PROTECTION Full Protection Overload, short circuit and reverse polarity protection Dimension (D x W x H) (mm / in) 300 x 360 x 88 / 11.8 x 14.2 x 3.5 Net Weight (kg / lb) 6.1 / / 16.3 Power Solutions for All Your Needs 〡 32

33 Smart Guard UPS Series Line Interactive UPS With Long Runtime Applications Home Appliances Office Equipment SMG-500 / 800 / 1000 / 1500AL SMG-2000 / 2500 / 3000 / 5000AL Motorize Equipment Medical Equipment 500 VA ~ 5 KVA pure sine wave output Wide input voltage range (140 ~ 275 VAC) Toroidal Transformer (C.R.G.O. Transformer) technology, more energy-saving Integrated frequency automatic tracking technology, generator compatible Excellent microprocessor control guarantees high reliability AVR function for voltage stabilization Large charging current design for external big capacity battery application Advanced battery management to increase battery longevity, performance and reliability Over discharge and overcharge protection Overload and short circuit protection Very low unloading current and audible noise Very low electromagnetic interference Battery connector reversed polarity protection (Optional) SMART GUARD LINE INTERACTIVE UPS SPECIFICATION MODEL SMG-500AL SMG-800AL SMG-1000AL SMG-1500AL SMG-2000AL SMG-2500AL SMG-3000AL SMG-5000AL Capacity 500 VA / 300 W 800 VA / 500 W 1000 VA / 700 W 1500 VA / 1050 W 2000 VA / 1400 W 2500 VA / 1800 W 3000 VA / 2100 W 5000 VA / 3500 W 220 VAC Range 140 ~ 275 VAC Range 45 ~ 65 Hz 220 VAC ± 3% for inverter; 190 ~ 245 VAC for AVR 50 / 60 Hz ± 0.3 Hz, subject to the main 4ms Waveform Pure sine wave Harmonic Distortion 3% TRANSFORMER Transformer C.R.G.O. toroidal transformer EXTERNAL Battery 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 48 VDC 48 VDC Charge 13.8 V ± 0.5 V 13.8 V ± 0.5 V 13.8 V± 0.5 V 27.6 V ± 0.6 V 27.6 V ± 0.6 V 27.6 V ± 0.6 V 55 V ± 1 V 55 V ± 1 V Low Battery Limit 10.9 V ± 0.3 V 10.9 V ± 0.3 V 10.9 V ± 0.3 V 21.8 V ± 0.6 V 21.8 V ± 0.6 V 21.8 V ± 0.6 V 42 V ± 1 V 42 V ± 1 V Battery Low Protection Point 10.2 V ± 0.3 V 10.2 V ± 0.3 V 10.2 V ± 0.3 V 20.5 V ± 0.6 V 20.5 V ± 0.6 V 20.5 V ± 0.6 V 41 V ± 1 V 41 V ± 1 V Charging Current (Programmable) 10 / 15 A 10 / 15 A 10 / 15 / 20 A 10 / 15 A 10 / 15 / 20 A 10 / 15 / 20 A 10 / 15 A 10 / 15 A PROTECTION Full Protection Overload / high temperature / output high voltage / output low voltage / battery low voltage / short circuit / over-charge / over-discharge / reversed polarity (optional) INDICATOR Display LED graphic Display Status Working & loading & battery Dimension (D x W x H) (mm / in) 340 x 146 x 210 / 13.4 x 5.7 x x 220 x 275 / 15.1 x 8.7 x 10.8 Net Weight (kg / lb) 6.7 / / / / / / / / 48.3 Power Solutions for All Your Needs 〡 33

34 Smart Power Series Pure Sine Wave Inverter With PWM Solar Charger 1000 VA ~ 5000 VA pure sine wave inverter Built-in 50 A internal PWM solar charge controller Selectable input voltage range for home appliances and personal computers Selectable charging current based on applications Configurable AC / Solar input priority via LCD setting Compatible to mains voltage or generator power Auto restart while AC is recovering Overload and short circuit protection INV-SP1000 PARALLEL FEATURE INV-SP2000/3000 INV-SP4000/5000(P) Parallel feature available with up to 6 units for INV-SP4000P / SP5000P model only (parallel card and cable are optional) Smart battery charger design for optimized battery performance Cold start function Home Equipment Office Equipment Lighting Systems Professional Workstations SMART POWER INVERTER SPECIFICATION MODEL INV-SP1000 INV-SP2000 INV-SP3000 INV-SP4000(P) INV-SP5000(P) CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 4000 VA / 3200 W 5000 VA / 4000 W 230 VAC Range (Selectable) 170 ~ 280 VAC (for personal computers) 90 ~ 280 VAC (for home appliances) Range 50 Hz / 60 Hz (auto sensing) Nominal 230 VAC AC Regulation (Batt. Mode) ± 5% 50 Hz / 60 Hz Surge Power 2000 VA 4000 VA 6000 VA 8000 VA VA Efficiency (Peak) 90% 93% 10ms (for personal computers) 20ms (for home appliances) Waveform Pure sine wave Battery 12 VDC 24 VDC 48 VDC Floating Charge 13.5 VDC 27 VDC 54 VDC Overcharge Protection 15.5 VDC 31 VDC 60 VDC Maximum AC Charge Current 10 A or 20 A (selectable) 20 A or 30 A (selectable) 60 A SOLAR CHARGER Charging Current 50 A Maximum PV Array Open Circuit 50 VDC 60 VDC 105 VDC Standby Power Consumption 1 W 2 W 2 W Dimension (D x W x H) (mm/in) 95 x 240 x 316 / 3.7 x 9.4 x x 272 x 355 / 3.9 x 10.7 x x 295 x 468 / 4.7 x 11.6 x 18.4 Net Weight (w/o Battery) (kg/lb) 5.0/ / / / /21.6 Power Solutions for All Your Needs 〡 34

35 Smart Solar Series Pure Sine Wave Inverter With Solar Charger 3000 ~ 5000 VA pure sine wave solar inverter Wide DC input range Configurable max. charging current by selecting AC charging current and solar charging current INV-S3000P INV-S3000M Home Equipment Office Equipment INV-S3000ML INV-S5000P INV-S5000M Lighting Systems Professional Workstations Built-in internal PWM or MPPT solar charge controller Configurable AC / Solar input priority via LCD setting Selectable input voltage range: wide range for home appliances or standard range for computers Compatible to mains voltage or generator power Auto restart while AC is recovering Overload and short circuit protection Cold start function Smart battery charger design for optimized battery performance SMART SOLAR INVERTER SPECIFICATION MODEL INV-S3000P INV-S3000M INV-S3000ML INV-S5000P INV-S5000M Capacity 3000 VA / 2400 W 5000 VA / 4000 W 230 VAC Range (Selectable) 170 ~ 280 VAC (for computers), 90 ~ 280 VAC (for home appliances) Range 50 / 60 Hz (auto sensing) AC Regulation (Battery Mode) 230 VAC ±5% Surge Power 6000 VA VA Efficiency (Peak) 90 ~ 93% 10ms (for computers); 20ms (for home appliances) Waveform Pure sine wave Battery 24 VDC 48 VDC Floating Charge 27 VDC 54 VDC Overcharge Protection 32 VDC 63 VDC SOLAR CHARGER & AC CHARGER Solar Charger Type PWM MPPT PWM MPPT Max. PV Array Open Circuit 75 VDC 100 VDC 145 VDC 105 VDC 145 VDC Max. Solar Charge Current 50 A 40 A 60 A 50 A 60 A Max. AC Charge Current 25 A 60 A Combined AC & Solar Max. Charge Current 70 A 60 A 120 A 110 A 120 A Interface USB Monitoring Software Various operating systems supported Dimension (D x W x H) (mm / in) 100 x 334 x 285 / 3.9 x 13.1 x x 440 x 300 / 3.9 x 17.3 x 11.8 Net Weight (kg / lb) 6.4 / / / / 〡

36 Smart Grid Series Pure Sine Wave Inverter With Solar Charger INV-G3000P INV-G3000M INV-G5000P INV-G5000M 3000 VA ~ 5000 VA pure sine wave solar inverter Configurable max. charging current by selecting AC charging current and solar charging current Built-in internal PWM or MPPT solar charge controller Boost and buck AVR User-configurable setting from LCD panel Selectable input voltage range: wide range for home appliances or standard range for computers Compatible to mains voltage or generator power Auto restart while AC is recovering Overload and short circuit protection Cold start function Smart battery charger design for optimized battery performance Intelligent slot: Option SNMP card or USB / RS-232 serial card for power monitoring management Parallel redundancy operation up to 6 units for INV-G5000P / INV-G5000M (optional) Home Equipment Office Equipment Lighting Systems Professional Workstations SMART GRID INVERTER SPECIFICATION MODEL INV-G3000P INV-G3000M INV-G5000P INV-G5000M Capacity 3000 VA / 2400 W 5000 VA / 4000 W 230 VAC Selectable Range 170 ~ 280 VAC (for computers), 90 ~ 280 VAC (for home appliances) Range 50 / 60 Hz (auto sensing) AC Regulation (Batt. Mode) 230 VAC ±5% AC Regulation (AVR Mode) 230 VAC ±10% Surge Power 6000 VA VA Efficiency (Peak) 90 ~ 93% 10ms (for computers); 20ms (for home appliances) Waveform Pure sine wave Battery 24 VDC 48 VDC Floating Charge 27 VDC 54 VDC Overcharge Protection 32 VDC 60 VDC SOLAR CHARGER Solar Charger type PWM MPPT PWM MPPT Max. PV Array Open Circuit 75 VDC 100 VDC 105 VDC 145 VDC Max. Solar Charge Current 50 A 40 A 50 A 80A Max. AC Charge Current 30 A 60 A Combined AC & Solar Max. Charge Current 80 A 70 A 110 A 140A Dimension (D x W x H) (mm / in) 340 x 380 x 88 / 13.4 x 15.0 x x 397 x 120 / 16.5 x 15.6 x 4.7 Net Weight (kg / lb) 12 / / / / 〡

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

MARUSON TECHNOLOGY. Uninterruptible Power Supply. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

MARUSON TECHNOLOGY. Uninterruptible Power Supply. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

MARUSON TECHNOLOGY. Uninterruptible Power Supply. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

MARUSON TECHNOLOGY.

MARUSON TECHNOLOGY. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

MARUSON TECHNOLOGY.

MARUSON TECHNOLOGY. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

On-line, Single Phase, Double Conversion UPS

On-line, Single Phase, Double Conversion UPS V Series Standard Universal Tower/Rack Mount 1, 2, 3 kva On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven Digital Signal Processor (DSP) achieving high reliability, while

More information

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. On-line, Single-phase Parallel Redundant UPS System.   6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set

More information

POWER UPS SOLAR INVERTER NEVER ENDS STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

POWER UPS SOLAR INVERTER NEVER ENDS STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY FSP Power Solution GMBH. Version 1.0 POWER NEVER ENDS STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY UPS SOLAR INVERTER FSP Group is the leading

More information

POWER NEVER ENDS UPS SOLAR INVERTER STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

POWER NEVER ENDS UPS SOLAR INVERTER STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY FSP Power Solution GMBH. Version 2.0 POWER NEVER ENDS STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY UPS SOLAR INVERTER FSP Group is the leading

More information

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven

More information

Series 120/120VAC Universal Tower/Rack Mount

Series 120/120VAC Universal Tower/Rack Mount V Series 120/120VAC Universal Tower/Rack Mount Standard 1000VA, 1500VA, 2000VA & 3000VA LB Extended Models 900VA, 1250VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features

More information

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Tower On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set user

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL ULTIMA W SERIES 1K/2K/3K Online UPS USER MANUAL Maruson Technology Corporation 18557 East Gale Avenue City of Industry, California 91748, U.S.A. Tel: +1-626-912-8388 Fax: +1-626-912-8680 Toll Free: 1-888-MARUSON

More information

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS MODEL NUMBER: S3M60KX Highlights Best-in-class footprint and power density minimize space requirements for up to 60kVA

More information

YOUR POWER IN SAFE HANDS. E Series UPS

YOUR POWER IN SAFE HANDS. E Series UPS E Series UPS YOUR POWER IN SAFE HANDS E Series UPS Secure Power The E Series UPS range from Dale Power Solutions Contents 1 Introduction 2 E-Series UPS Power Matrix 4 E200 Series 1 3kVA 6 E200 Series 6

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT40K Highlights On-line double-conversion topology, VFI operation

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired MODEL NUMBER: SU20K3/3 Description Tripp Lite's SU20K3/3 20kVA SmartOnline

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity

More information

In our world, everything is built to last.

In our world, everything is built to last. - DC UPS - Standby UPS - Line Interactive UPS - - Outdoor UPS - AVR In our world, everything is built to last. Advancing Power VOLTRONIC POWER TECHNOLOGY CORP. Taiwan: No. 406, Xinhu 1st Road, Neihu District,

More information

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3 User Manual PF0.9 1K/2K/3K Online UPS Uninterruptible Power Supply System Version: 1.3 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation...

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Onfiniti. 1 Phase UPS

Onfiniti. 1 Phase UPS Onfiniti 1 Phase UPS Today's business continuity demands a cost-effective power protection solution, for ensuring Power Continuity and Power Quality with optimal Total Cost of Ownership (TCO). The UPS

More information

» Sophisticated» Reliable» Intelligent

» Sophisticated» Reliable» Intelligent PowerGem Pro Series Single and Three Phase Input & Single Phase Output True Online Double Conversion UPS 6kVA 30kVA PowerGem Pro Series» Sophisticated» Reliable» Intelligent VFI The PowerGem Pro is the

More information

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS Product Catalog www.cyberpower.com www.cyberpower.com ONLINE S 3-PHASE SERIES (15/20KVA, 3 PHASE IN 1 PHASE OUT) VERSATILE POWER PROTECTION

More information

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications True double-conversion online single-phase UPS PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications Safeguarding your power supply has never been easier One factor has become increasingly

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation

More information

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) Local Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and

More information

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility OFF-GRID PV IVERTERS EssenSolar & Expert series Solution on Unstable or Remote Area without 1kW-5kW FSP Off-Gird Inverters: EssenSolar & Expert series An ideal Off-Grid inverter for households, FSP Off-Grid

More information

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass APC Smart-UPS VT, 24 kw / 30 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA Est.1968 ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA Maximise your availability with ComPower Mini Designed and Published by Thycon. ComPower Mini is a midsize, three-phase UPS system that delivers premium

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection

More information

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA Important Safety Information Before installing UPS Endure 500VA/750VA/1000VA/2000VA, please read the operating instructions carefully.

More information

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS magellan commercial UPS solutions Magellan Power Modular - Flexible UPS Commercial UPS Solutions 2 MPM3320-60kVA MPM3320-100kVA MPM3320-200kVA MPM3340-400kVA MPM3340-520kVA 2015 W www.magellan-power.com.au

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4 USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL GXT4 5000 & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL 1.1 SUMMARY This specification shall define the electrical and mechanical characteristics and requirements for a continuousduty,

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Alphapower HTU UPS. Some key features include:

Alphapower HTU UPS. Some key features include: The is a durable, high operating temperature UPS, ideal for outdoor applications. It is a combination of an inverter, battery charger and AC transfer switch in one complete system with a peak conversion

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED 2033A Series UNINTERRUPTIBLE POWER SUPPLY SYSTEMS Where Reliability Breeds Confidence ISO 9001 CERTIFIED Superior Performance, Reliability and Safety Come from Experience. Our Uninterruptible Power Supply

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

Inform Company Profile

Inform Company Profile Inform Company Profile Inform Electronic, one of the European leading power solution specialist, is established in 1980 with the aim of designing and building industrial electronic systems. Soon after,

More information

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC) TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)

More information

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual www.powershield.com.au 0 Introduction Thank you for choosing PowerShield. PowerShield Centurion UPS series are designed to provide

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01

More information

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K User M anual Rack/Tower Online UPS 1K/1.5K/2K/3K Uninterruptible Power Supply System Version: 1.2 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3.

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications Three-phase UPS system DPA UPScale ST 10 200 kw The modular UPS designed for lowand medium-power applications DPA UPScale ST always protecting your critical applications Up to 10 modules in parallel per

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems 3 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 500-3000VA, 120V and 230V. On-Line

More information

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms) LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES BM Plus Series BMLM 10-20 kva Single-phase BMLT 10-120 kva Three-phase CASH REGISTERS TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP)

More information

MERU Solar Off-Grid Inverters

MERU Solar Off-Grid Inverters 1 kva / 2 kva Off-Grid Solar Inverters with LCD and LED displays 24 / 48 VDC battery versions for 1 kva and 48 VDC for 2 kva Pure sine wave with highest efficiency Fully configurable (PV / Grid priority

More information

Liebert GXT MT+ User Manual VA Installer/User Guide

Liebert GXT MT+ User Manual VA Installer/User Guide Liebert GXT MT+ User Manual - 1000-3000 VA Installer/User Guide Table of Contents 1. Important Safety Warning 1 1-1. Transportation 1 1-2. Preparation 1 1-3. Installation 1 1-4. Operation 1 1-5. Maintenance,

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models and uses

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The Supreme series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models

More information

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution 10kVA - 60kVA Compact, Efficient, and Reliable Power Solution Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS SINGLE-PHASE SOLUTIONS INNOVATIVE UPS SOLUTIONS FOR CRITICAL APPLICATIONS Toshiba Uninterruptible Power Systems (UPS) features a specialized suite of

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

User Manual V1.0 MaxiFlex 3000

User Manual V1.0 MaxiFlex 3000 User Manual V1.0 MaxiFlex 3000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2 1-5. Maintenance,

More information

Inform Company Profile

Inform Company Profile Inform Company Profile Inform Electronic, one of the European leading power solution specialist, is established in 1980 with the aim of designing and building industrial electronic systems. Soon after,

More information

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount FN Series Scalable N+ UPS kva to kva Rackmount Advanced Features: * Parallel Rackmount Units with a Single of up to kva * True N+ Redundancy * ECO Mode: 97% Efficiency * DSP Double-Conversion On-line Sinewave

More information

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL CSI 263353.01EDR Static Uninterruptible Power Supply Systems Endeavor Series MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.1 SUMMARY

More information

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS Elektra Series (3/3, H.F) (10KVA~500KVA) Elektra Series I.T Grade On Line Double Conversion UPS

More information

Master DIALOG INDUSTRY RANGE

Master DIALOG INDUSTRY RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications

More information

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerWave 33 Efficient power protection for today s IT and process-related work environments ARTICLE OR CHAPTER TITLE PowerWave 33 Efficient power protection for today s IT and process-related work environments Cooling fan UPS control panel Maintenance bypass isolator Input supply isolator Slot

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems. SENTRY HPS HM/HT provides maximum protection for vital mission-critical networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation SUN MAGIC + SUN MAGIC + is a state of art PCU product from ENERTECH product basket with Global standards. This unit will give operational flexibility to its customers to enjoy the benefits of advanced

More information

Up to 98% efficient under full load Similar runtimes to the previous 3u model

Up to 98% efficient under full load Similar runtimes to the previous 3u model New Model replacing the PS6003rm3uXL Up to 98% efficient under full load Similar runtimes to the previous 3u model @ 1,000 800 600 400 200 : ' 100 e 80 " E 60 ~ " "' 40 20 10 8 500 1,000 1,500 2,000 2,500

More information

1. Important Safety Warning

1. Important Safety Warning Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation... 1 1-5. Maintenance, service and faults... 2 2. Installation and

More information

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices Enhanced Power Services Limited Local Area Networks (LAN) Servers Data Centres Cash Registers Telecomunication Devices e-business (Server Farms, ISP/ASP/POP) Industrial PLCs Electro Medical Devices Emergency

More information

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online online UPS 10 20 kva single/single-phase and three/single-phase 10 120 kva three/three-phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS INTERNET CENTERS (ISP/ASP/POP) TELEcOMmUNICATIoN DEVICES E-BUSINESS

More information

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters

More information

USER MANUAL DN / DN

USER MANUAL DN / DN USER MANUAL DN-170040/ DN-170041 Online UPS Uninterruptible Power Supply System Version:1.0 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation...

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

Solar Inverter Manual

Solar Inverter Manual Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage

More information