2 Page 2 of 8 CONTENTS 2.1 Introduction Scope Guidelines Applicable Documents General description Identification of the PCDU main features PCDU customization Primary power bus Heaters command interfaces Switching and Distribution Battery Interface Heaters interface... 6
3 Page 3 of Introduction The management of the Sentinel 5P power bus is ensured by the PCDU which interconnects the Solar array and the Battery to a central point called STAR POINT This document is based on the AS250 PCDU specification [AD-04] and defines the modifications which shall be considered for Sentinel 5 Precursor. 2.2 Scope The present specification only provides the differences from the AS250 PCDU specification [AD-04]. Three cases are considered: when AS250 PCDU requirements are applicable, they are not repeated within this specification. when a requirement or complete section of the AS250 specification are not applicable, they are declared as Not Applicable. [777] when a requirement of the AS250 specification is modified (customised), they are identified by a specific requirement number and associated to the original AS250 requirement number as explained below. 2.3 Guidelines [778] The Doors requirement Number is presented under the following format -PCDU-yyy/ /a,b/ where: yyy is the requirement number from the original requirement in the AS250 PCDU specification [AD-04] (if any), a,b are the intended verification methods. 3 APPLICABLE DOCUMENTS [779] [AD-04] DIV-SP T-ASTR (Issue3 September 2010) AS250 Generic Power Conditioning and Distribution Unit (PCDU) Requirement Specification 4.1 General description [25] The Power Conditioning and Distribution Unit (PCDU) is in charge of the following activities: conditioning of primary power source from SA and battery, Battery charge control by hardware control loop implementation of the power distribution star point and filtering, distribution of protected and unregulated voltage outlets towards users. Voltage range between 26V and 33.6V during nominal operational mode and between 22V and 33.6V during acquisition and safe modes. distribution of switched, protected and unregulated power lines towards heaters Bus undervoltage protection Battery connection/disconnection to the primary bus Battery modules coupling actuation of release initiators On-ground operability communication with the on-board computer interfacing a redunded MIL-Std-1553 bus [6] [774] [775] [776]
4 Page 4 of Identification of the PCDU main features AS250 generic PCDU SA input power range Maximum current at battery interface Distribution maximum output power Bus voltage range Number of deployment devices actuation up to 50A 50A 1500W 22-37V (16 N + 16R) Distribution configuration min MAX (note) Number of distributed protected outputs at least to 56 (note) [30] Number of heating outlets at least (36N+36R) up to (56N+56R) (note) note: If number of LCLs is higher than 50, number of avialble heater lines will be lower than (56N+56R) Table 4.2-1: AS250 PCDU main features 4.4 PCDU customization [620] The PCDU customisation is performed by fulfilling the values specific to the project in the Table in Column "Project" If some additional modifications are required, the procedure described in section 2.3 shall be used. [618] The Table provides for a set of keys parameters: the AS250 range (columns " Generic" min/max) the corresponding AS250 PCDU requirement number (columns "Generic" requirement number) the customized value (column "Project"). AS250 PCDU Specification Sentinel 5P Generic Parameters min max (note2) requirement number Total number of SA sections PCDU-133 Maximum current at SA interface 57-50A (8.33A per section) PCDU-391 Number of battery modules PCDU-183 Maximum total current at battery interface 30A - 50A PCDU- 324,325&403 Battery charge current limitation 30A 15A 50A PCDU-324 Battery charge current safety limitation 30A - 50A PCDU-325 Battery voltage limitation 33.6V 29.6V 33.6V to 36V(note1) PCDU-318 Battery voltage safety limitation 33.6V 33.6V to 36.4V(note1) PCDU-319 Battery impedance 60 mohm 8 mohm 120 mohm PCDU nh nh Bus voltage 22-35V 22V 35V to 37V PCDU-378 Satellite maximum consumption W PCDU-382 Number of LCL & FCL to 56 (note3) PCDU- 235,703,744,748, 749 Number of heater lines (Nominal+Redundant) (56+56) (36+36) (56+56) (note3) PCDU-293 & 703 Number of heater lines of maximum bus voltage (1+1) - (1+1) (note3) Number of heater lines of maximum bus voltage (11+11) (12+12) (15+15) (note 3) Number of heater lines of maximum bus voltage (44+44) (24+24) (40+40) (note3) PCDU- 409,378,703, 744, 751 Number of deployment devices actuation ( ) (16+16) PCDU-267 Deployment device type Heating De vice EED or Heating device PCDU-271 (note1) depending of Battery technology used (note2) without extra board (note3) if number of LCL is higher than 50, number of available heater lines will be lower than (56+56) [612] Table 4.4-1:PCDU customisation
5 Page 5 of Primary power bus -PCDU-197 / / T,R / Modified The PCDU shall be designed to provide a 28V non-regulated primary power bus FCL & LCL functional requirements -PCDU-232 / / R / Modified PCDU shall distribute a total of at least 50 protected and switched outputs. 5.9 Heaters command interfaces -PCDU-293 / / R / Modified Each nominal and redundant section shall be able to drive at least 56 non cross-strapped isolated heaters. -PCDU-294 / / T,R / Modified The heaters of each section shall be split in at least 6 groups supplied each by distinct primary power lines, each one being protected by a LCL of the bistable type. 6.4 Switching and Distribution -PCDU-235 / / R / Modified The allocation of LCLs/FCLs to classes for the minimum configuration of Table (48 LCL/FCL and 2x36 heater lines) shall be as specified in the table here below: LCL Classes LCL FCL Limiter/Breaker With rearmable breaker Automatic rearming Class up to among 30 LCL can be configured as FCL class up to 2 Class up to 6 9 N/A Class up to 8 3 N/A Class up to 10 6 N/A Total 48 The quantities of LCL per classes are defined according classes definition in PCDU-337 & PCDU PCDU-748 / / R / Modified The allocation of LCLs/FCLs to classes for the maximum configuration of Table (50 LCL/FCL and 2x56 heater lines) shall be as specified in the table here below: LCL Classes LCL FCL Limiter / Breaker With re-armable breaker Automatic rearming Up to (and including) among 30 LCL can be configured as FCL class up to 2 Up to (and including) 6 11 N/A Up to (and including) 8 3 N/A Up to (and including) 10 6 N/A Total 50 The quantities of LCL per classes are defined according classes definition in PCDU-337 & PCDU- 340.
6 Page 6 of generic -PCDU-378 / / T / Modified The PCDU shall provide a maximum power within a voltage range of 22V to 35V DET -PCDU-391 / / T,A,R / Modified PCDU shall be designed for a maximum input current at SA interface of 57A -PCDU-395 / / T,R / Modified The number of Solar array sections is equal to 6 as required in PCDU-133. The PCDU design shall be compatible with a 6 sections Solar Array configuration (9.5A maximum per section) Battery Interface -PCDU-403 / / T / Modified The PCDU shall interface with the Battery composed of two modules, connected in parallel within the PCDU, with the following characteristics: the battery voltage will be in the range V the battery total discharge current will be lower than 30 A battery impedance: 8m <R<120m DC 3000n H AC The minimum battery impedance corresponds to a 156Ah battery module composed by two 78Ah battery modules in paralell or one 156Ah battery module. The maximum battery impedance corresponds to one battery module of 78Ah connected at PCDU output Heaters interface -PCDU-409 / / T,R / Modified Each section as specified in PCDU-293 is composed of a total of 36 lines split as follow: 12 lines of 35V 24 lines of 35V -PCDU-751 / / T,R / Modified Each section of extra lines as specified in PCDU-703 is composed of a total of 20 lines maximum split as follow: 1 line of Vbus=35V 3 lines of Vbus=35V 16 lines of Vbus=35V The heaters of each section shall be split in up to 3 groups supplied each by distinct primary power lines, each one being protected by a LCL of the bistable type.
7 Page 7 of 8
8 Page 8 of 8 DOCUMENT CHANGE DETAILS DISTRIBUTION LIST INTERNAL EXTERNAL Configuration Management
ELECTRICAL POWER, DIRECT CURRENT, SPACE VEHICLE DESIGN REQUIREMENTS
MIL-STD-1539 (USAF) 1 AUGUST 1973 MILITARY STANDARD ELECTRICAL POWER, DIRECT CURRENT, SPACE VEHICLE DESIGN REQUIREMENTS FSC 1810 Electrical Power, Direct Current, Space Vehicle Design Requirements MIL-STD-1539
More informationSP PRO KACO Managed AC Coupling
SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load
More informationPERFORMANCE SPECIFICATION SHEET BATTERY, RECHARGEABLE, NICKEL CADMIUM, VENTED, 1.2-VOLT, 13 AMPERE- HOUR, BB-475/A CELL
INCH-POUND 25 FEB 2011 PERFORMANCE SPECIFICATION SHEET BATTERY, RECHARGEABLE, NICKEL CADMIUM, VENTED, 1.2-VOLT, 13 AMPERE- HOUR, BB-475/A CELL This specification is approved for use within Army CECOM Life
More informationCustom Power Solar Radian Battery Energy Storage System
1442A Walnut St #368 Berkeley, CA 94709 (510) 912-4662 http://www.custompowersolar.com October 8, 2017 Custom Power Solar Radian Battery Energy Storage System Custom Power Solar provides residential energy
More informationE61, E63, E64 BMW AG - TIS
VS-42 je Baugruppe/Group: 61 meeknet.co.uk/e64 Power supply E60, E61, E63, E64 61 07 03 (029) weltweit Datum/Date: 06/2003 Update 02/2006 Introduction The power supply on the BMW 5- and 6-Series is similar
More informationSINGLE-POLE SWITCHES SWITCHES
SINGLE-POLE SWITCHES SWITCHES MITEQ offers a broad line of switches covering multioctave bands from 0.2 to 18 GHz. Single-pole, single-throw through single-pole, seven-throw switches are available as standard
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,
More informationSTAR. series. 2-Stage Servovalve Rated flows up to 120 l/m. Features
STR series 11 2-Stage Servovalve Rated flows up to 12 l/m Features Maximum operating pressure 5 bar Electric feedback at main stage spool ISO 441-5-5-4 mounting pattern (NG1) Internal or pilot supply &
More informationComplex Modeling of Li-Ion Cells in Series and Batteries in Parallel within Satellite EPS Time Dependent Simulations. Patrick Bailey, ENNEAD, LLC
Complex Modeling of Li-Ion Cells in Series and Batteries in Parallel within Satellite EPS Time Dependent Simulations Patrick Bailey, ENNEAD, LLC Aerospace Space Power Workshop April 16-19, 2012 Manhattan
More informationSeminar 12! The Future of Space Flight! Spacecraft Power & Thermal Control!
Seminar 12! The Future of Space Flight! Spacecraft Power & Thermal Control! Robert Stengel! FRS 112, From the Earth to the Moon! Princeton University, 2015! " NASA s Strategic Direction! Rationales and
More informationA NOVEL IN-FLIGHT SPACE BATTERY HEALTH ASSESSMENT SYSTEM Brandon Buergler (1), François Bausier (1)
A NOVEL IN-FLIGHT SPACE BATTERY HEALTH ASSESSMENT SYSTEM Brandon Buergler (1), François Bausier (1) (1) ESA-ESTEC, Keplerlaan 1, 2200 AG Noordwijk, NL, Email: brandon.buergler@esa.int, francois.bausier@esa.int
More informationMaxi and Mini DC-DC Converter Evaluation Board
BRICK FAMILY USER GUIDE Maxi and Mini DC-DC Converter Evaluation Board Features...1 Introduction...2 Set Up + OUT, OUT...3 + S, S...3 Secondary Control (SC)...3 Primary Control (PC)...4 Parallel (PR)...4
More informationPreliminary Design of the Electrical Power Subsystem for the European Student Moon Orbiter Mission
Preliminary Design of the Electrical Power Subsystem for the European Student Moon Orbiter Mission Steve Ulrich Jean-François Veilleux François Landry Corbin Picture courtesy of ESA Presentation Outline
More informationSAFT VES16 SOLUTION FOR SMALL GEO
SAFT VES16 SOLUTION FOR SMALL GEO Emmanuel Bonneau (1), Stéphane Remy (1) (1) Saft, Space and Defence Division, Rue Georges Leclanché 86060 Poitiers France, Email: emmanuel.bonneau@saftbatteries.com, stephane.remy@saftbatteries.com
More informationOASIS. Standby Instrument System. Installation Manual. Aerosonic Corporation September 18, N. Hercules Ave. Clearwater, FL USA
OASIS Standby Instrument System Installation Manual Aerosonic Corporation September 18, 2012 1212 N. Hercules Ave. Clearwater, FL 33765 USA INSTALLATION MANUAL OASIS Original Aerosonic Standby Instrument
More informationInverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.
Inverter / Charger Accessory for Steca Solarix PLI 5000-48 3-Phase / Parallel Kit Installation and operating instructions GB Z01 17.31 Table of Contents About this Manual... 2 Purpose... 2 Scope... 2 Keywords
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationSynthesis Twin. from 6 to 20 kva
Synthesis Twin from 6 to 20 kva Maximum safety for high-risk applications Increased security Synthesis Twin, featuring parallel configuration compatibility of up to 3 units, provides a higher level of
More informationNASA Glenn Research Center Intelligent Power System Control Development for Deep Space Exploration
National Aeronautics and Space Administration NASA Glenn Research Center Intelligent Power System Control Development for Deep Space Exploration Anne M. McNelis NASA Glenn Research Center Presentation
More informationFirst Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network
First Responder System Identification Quiz Presented by the NY-SUN PV Trainers Network SYSTEM 1 Questions: 1) Is there a solar electric system at the site? 2) What is your next step? SYSTEM 1 3) Given
More informationGEO Dual Mode PPU & LEO HEMPT PPU
GEO Dual Mode PPU & LEO HEMPT PPU EPIC Workshop 2017 Madrid 24-25 Oct 1 Presentation Plan Thales Alenia Space in Belgium, previously named ETCA was created in 1963, 54 years' experience in power supplies
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationFigure 3: Schematic (switch shown installed on both MLB Lower Ring & Upper Ring). Switch is SPDT-DB (Form Z)
Feature Significant spaceflight heritage Sealed, Sub-Miniature, Snap- Action Meets MIL-PRF-8805 enclosure design symbol 3 Gold contacts Test verified Variable installation Benefit TRL9. More than 200 have
More informationN-03 STEERING GEAR CONTROL SYSTEMS
Guideline No.: N-03(201510) N-03 STEERING GEAR CONTROL SYSTEMS Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements,
More informationSP PRO ABB Managed AC Coupling
SP PRO ABB Managed AC Coupling Introduction The SP PRO ABB Managed AC Coupling provides a method of linking the ABB PVI-3.0/3.6/4.2- TL-OUTD and ABB PVI-5000/6000-TL-OUTD string inverters to the SP PRO
More informationMSR01. Water heating controller with solar panel support
MSR01 Water heating controller with solar panel support version 1.4 trading Czech Republic Czech Republic 1 Content 1. Device description...3 2. Device interface...3 2.1. Inputs...3 2.2. Low tariff...3
More informationPlug Into the Current Future
Green Energy Solutions & Electric Mobility Plug Into the Current Future enquiries@freedomwon.co.za +27(0)71 890 9958 +27(0)82 256 7430 www.freedomwon.co.za Leading Lithium (LiFePO4) battery energy storage
More informationIRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION
IRT quality IN MOTION www.irtsa.com 4000 AT-S/M/L Technical Manual IRT quality IN MOTION E2 0 8 4 1 5 September 2013-Rev. 5 UL Requirements Drives Series 2000 / 4000 AT 1. Field wiring terminal to use
More informationTeam 2228 CougarTech 1. Training L2. Electrical Design and Control System Wiring
Team 2228 CougarTech 1 Training L2 Electrical Design and Control System Wiring Team 2228 CougarTech 2 Objectives Understand: Understand the electrical design process Understand the control system wiring
More informationPlug Into the Current Future
Green Energy Solutions & Electric Mobility Plug Into the Current Future enquiries@freedomwon.co.za +27(0)71 890 9958 +27(0)82 256 7430 www.freedomwon.co.za Leading Lithium (LiFePO4) battery energy storage
More informationseries 2-Stage Servovalve Rated flows up to 20 l/m Features
series 46 2-Stage Servovalve Rated flows up to 2 l/m Features Standard & high response versions Maximum operating pressure 15 bar ISO 441---4 mounting pattern Internal pilot supply (4 port) Suitable for
More informationEFFEKTA Power Supplies
EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power
More informationS. Jabez Dhinagar Ph.D Vice President. TVS Motor Company Ltd. 21 st November 2008, NI Bangalore
S. Jabez Dhinagar Ph.D Vice President Advanced Engineering TVS Motor Company Ltd. 21 st November 2008, NI Bangalore CONTROL SYSTEM DEVELOPMENT CYCLE System Definition System Testing Rapid Prototyping Hardware
More informationIES GRID FEED-IN LIMITER
IES GRID FEED-IN LIMITER Installation and User Manual Models SPS01101-ABB SPS01303-ABB CONTAINS IMPORTANT INSTALLATION AND TESTING PROCEDURES THAT MUST BE FOLLOWED TO ENSURE COMPLIANCE WITH ENERGEX AND
More informationPOWER CONTROL SYSTEM FOR THE AGILE SATELLITE
POWER CONTROL SYSTEM FOR THE AGILE SATELLITE G. Ebale (1), A. Lamantia (1), M. La Bella (1) (1) Blu Electronic s.r.l. via Gallarate,150. 20151 Milano (Italy), Email: giorgio.ebale@bluelectronic.it; antonio.lamantia@bluelectronic.it;
More informationIndustrial Chargers and
Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines
More informationDefinitions. Scope. Customer Generation Interconnection Requirements
Updated 02/1 Page 1 Scope The purpose of this document is to describe Idaho Power s requirements for the installation and testing of Customer Generation acilities that are interconnected with Idaho Power
More informationBattery Management System (BMS) Installation guide and manual
Battery Management System (BMS) Installation guide and manual BMS manual with software version 3.32BT - 1-23.03.2012 General safety informations when operating with the Battery Management System BMS: Control
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201705) E-15 Uninterruptible Power Systems (UPS) Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,
More informationAPPLICATION NOTES DELOMATIC
APPLICATION NOTES DELOMATIC 400 Safety system Document no.: 4189340885B SW version 1.33.3 or later Table of contents 1. ABOUT THIS DOCUMENT... 3 GENERAL PURPOSE... 3 INTENDED USERS... 3 CONTENTS/OVERALL
More informationProportional pressure reducing valve, in 3-way version
roportional pressure reducing valve, in 3-way version RE 29184/06.11 Replaces: 12.02 1/12 ype 3DRE and 3DREE Size 6 Component series 2X Maximum operating pressure Maximum flow 100 bar 15 l/min able of
More informationPowerware Master Modbus
Powerware Master Modbus Map 164201391 Rev D This document describes the format of the data contained in the Modbus messages. Not all registers apply to all UPS modules. Please consult the individual UPS
More informationseries 2-Stage Servovalve Rated flows up to 55 l/m Features
series 456 2-Stage Servovalve Rated flows up to 55 l/m Features Standard & high response versions Maximum operating pressure 15 bar Special mounting pattern Internal pilot supply (4 port) Suitable for
More informationCopyright 2003 Advanced Power Technologies, Inc.
Overview of the Standard for Interconnecting Distributed Resources with Electric Power Systems, IEEE 1547 and it s potential impact on operation of the Distributed Generation (DG) systems and on the design
More informationMcQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997
Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call
More informationPhosphate-base Lithium-ion Battery Pack Model:LFP V 1350Ah Product Specifications Lithium Energy Solution 1/8
Phosphate-base Lithium-ion Battery Pack Model:LFP1350-48 48V 1350Ah Product Specifications Lithium Energy Solution 1/8 1. Product overview LFP1350-48 Products are mainly for customized development of high
More informationMar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)
2101 Commonwealth Blvd, Suite B Ann Arbor, MI 48105-5759 www.med.umich.edu/facilities/plan/ 263010-H: SUPPLEMENTAL PARALLELING GEAR (16315-H) Related Sections Basis Guideline: N/A For an explanation of
More informationSTAR. series. 2-Stage Servovalve Rated flows up to 7 l/m. Features
STAR series 2 2-Stage Servovalve Rated flows up to 7 l/m Features Miniature design Maximum operating pressure 315 bar ISO 1372-1-1--92 mounting pattern Internal pilot supply (4 port) Suitable for 3-way
More informationEuropean Technical Standard Order (ETSO)
Date: 28/11/2008 European Aviation Safety Agency European Technical Standard Order (ETSO) Subject: BATTERY BASED EMERGENCY POWER UNIT (BEPU) 1 - Applicability This ETSO gives the requirements which Battery
More informationSTAR. series. 2-Stage Servovalve Rated flows up to 20 l/m. Features
STAR series 454 2-Stage Servovalve Rated flows up to 2 l/m Features Standard & high response versions Maximum operating pressure 15 bar ISO 172-2-2-2 mounting pattern Internal pilot supply (4 port) Suitable
More informationFOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E
Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...
More informationDER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.
Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.3, 5/16/18 1.0 Scope This document is currently limited in scope to inverter interfaced PV installations
More informationFeasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation
Feasibility Study Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection J.E.D. Solid Waste Management Facility Holopaw Substation September 2013 1 of 12 Table of Contents GENERAL... 3 SHORT
More informationPresented at the 2012 Aerospace Space Power Workshop Manhattan Beach, CA April 16-20, 2012
Complex Modeling of LiIon Cells in Series and Batteries in Parallel within Satellite EPS Time Dependent Simulations Presented at the 2012 Aerospace Space Power Workshop Manhattan Beach, CA April 16-20,
More informationNR Electric Uses RT-LAB Real-time Simulator to Test the Control and Protection System for the Zhoushan Multiterminal
NR Electric Uses RT-LAB Real-time Simulator to Test the Control and Protection System for the Zhoushan Multiterminal MMC-HVDC Project Located in Zhoushan, Zhejiang Province, China, the Zhoushan MMC-HVDC
More informationMA-4025 Solar Charger Patent pending
Features Portable Fast-Charge Solar Battery Charger Maximum Power Point Tracking Up to 30% more power No User Input Required Fully Ruggedized Design Over Temperature Protection Wide-Range DC Input Capable
More informationTECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT
TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters
More informationBETA Low-Voltage Circuit Protection
BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature
More informationOpen Rack Hardware v0.6
Open Rack Hardware v0.6 Authors: Pierluigi Sarti, System Designer Jon Ehlen, Mechanical Engineer 1 Scope This document describes the technical specifications for the custom rack that houses Open Compute
More informationUser Assembly and Operation Manual
ITEM: DESCRIPTION: 5800200 User Assembly and Operation Manual Part One Safe Use and Operation Page 2 Part Two Parts Identification Page 3 Part Three Assembly and Installation Page 4 Installation Tips:
More informationMILITARY SPECIFICATION MICROCIRCUITS, LINEAR, CMOS, ANALOG SWITCH WITH DRIVER, MONOLITHIC SILICON
INCH-POUND 4 February 2004 SUPERSEDING MIL-M-38510/116 16 April 1980 MILITARY SPECIFICATION MICROCIRCUITS, LINEAR, CMOS, ANALOG SWITCH WITH DRIVER, MONOLITHIC SILICON This specification is approved for
More informationEmergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1
pplication description EN Emergency-off application Manual motor starter MS116/MS132 Undervoltage release U1 The emergency-off application allows machine and job safety for nominal currents up to 32 all
More informationSolar Inverter Manual
Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage
More informationPower Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva
Power Safety Protect 8. Industrial UPS Protect 8.31 Single Phase output 10 kva 120 kva Protect 8.33 Three Phase output 10 kva 120 kva 400 V AC input 220 V DC The Building Block UPS Engineering is our Business
More informationA. General Specifications. B. Dimensional Layout. BTU International Specification: Model 150Nz12 Reflow Solder System Date: 11/05/09 Page: 1/6
Page: 1/6 A. General Specifications Maximum temperature rating (all zones): 350 C Nominal operating temperature: 80-350 C Number of controlled heated zones: 12 Top 12 Bottom Oven atmosphere: Air/N 2 Working
More informationContents. 1 Introduction. 2 General Product Information. 3 General Test Requirements
1 Introduction 1.1 Purpose......................................... 1 1 1.1.1 Reasons for Issue 2............................... 1 2 1.2 Scope.......................................... 1 2 1.3 Environmental
More informationCompression load cell Inteco, converter Connexx, mounting kits PR 6001, PR 614x
Compression load cell Inteco, converter Connexx, mounting kits PR 6001, PR 614x The versatile, innovative weighing solution for silo and vessel weighing The load cell Inteco represents a consistent enhancement
More informationL I T H I U M B AT T E R Y
VERSION 1.5 L I T H I U M B AT T E R Y ENERGY SOLUTION I N C O R P O R A T I N G Installation Guide LG CHEM MODEL NO. EM48126P3S ABB DC DISTRIBUTION BOARDS Contents 3. Notices 4. Before You Begin 7. Bill
More informationBUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.
BUSSMANN SERIES Pre-production and sample electric vehicle power fuses 500 Vdc, 50-400 A 2011/65/EU Agency information Designed to: JASO D622 ISO 8820-8 Manufactured under a IATF 16949 quality system for
More informationRTDS Implementation of Notional Four Zone MVDC Shipboard Power System
RTDS Implementation of Notional Four Zone MVDC Shipboard Power System Document for the ESRDC Team RTDS Implementation of Notional Four Zone MVDC Shipboard Power System 02/22/2018 Version 1.0 Personnel
More informationTHE KOREASAT5 PROGRAM
THE KOREASAT5 PROGRAM - Design, AI&T, Launch and Operation KT CORPORTION Contents I. Introduction II. Design III. Assembly, Integration and Test (AI&T) IV. Launch V. Operation VI. Q & A THE KOREASAT 5
More informationGUIDE TO BACK UP POWER
GUIDE TO BACK UP POWER Considerations for Energy Storage Assets CHIP PALOMBINI cpalombini@dynapower.com Power Outages Cost the United States Tens of Billions of Dollars Each Year C & I bears 98% of the
More informationQS20.241, QS C1
QS2.21, QS2.21C1 QSeries 27. APPLICATION NOTES 27.1. REPETITIVE PULSE LOADING Typically, a load current is not constant. It varies over time. For pulse load compatibility, following rules must be met:
More informationType 2000 Transducer Product Instructions
Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two
More informationIntelligence in Substation Automation
Wolfgang Wimmer ABB Switzerland Intelligence in Substation Automation Summer Workshop of Swiss Chapter of IEEE PES, 05-06-02 ABB Switzerland AG - 1 - Contents ABB Switzerland AG - 2 - The role of Substation
More informationProportional pressure relief valve Type DBETRE
RE 9 68/.99 Proportional pressure relief valve Type DBETRE Nominal size 6 Series X Max. operating pressure 5 bar Max. flow up to L/min H/A/D 67/99 Type DBETRE-X/ G4KA with integrated control electronics
More informationExomars Orbiter Module Bus OMB
Exomars Orbiter Module Bus OMB TAS-F 23rd Sept 2010 Exomars Industrial day- Turin 1 Exomars OMB definition Exomars OMB will: serve as a carrier to deliver the EDM at the right landing latitude in the 2016
More informationBehaviour of battery energy storage system with PV
IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. Issue 9, September 015. ISSN 348 7968 Behaviour of battery energy storage system with PV Satyendra Vishwakarma, Student
More information2-way proportional throttle valve for block installation
-way proportional throttle valve for block installation RE 90/07.05 Replaces: 03.00 / Types FE; FEE Size 6 Component series X Maximum operating pressure 35 bar Maximum flow 90 L/min bei p = 0 bar H4538
More informationPower Electronics & Drives [Simulink, Hardware-Open & Closed Loop]
Power Electronics & [Simulink, Hardware-Open & Closed Loop] Project code Project theme Application ISTPOW801 Estimation of Stator Resistance in Direct Torque Control Synchronous Motor ISTPOW802 Open-Loop
More informationSWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)
PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Issue 3 2012 SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) www.energynetworks.org 2012 Energy Networks
More informationSMC Standard SMC-S June Supersedes: New issue. Air Force Space Command SPACE AND MISSILE SYSTEMS CENTER STANDARD
BY ORDER OF THE COMMANDER SMC Standard SMC-S-007 13 June 2008 ------------------------ Supersedes: New issue Air Force Space Command SPACE AND MISSILE SYSTEMS CENTER STANDARD SPACE BATTERY APPROVED FOR
More informationSMPPT. Solar Charge Controller with Maximum Power Point Tracking. Installation & Operation Manual
SMPPT Solar Charge Controller with Maximum Power Point Tracking 10A/20A/30A 12V/24V Installation & Operation Manual 1 Dear Consumer: Thank you very much for using our product! We will offer you the permanent
More informationPower conversion systems for energy storage. Engineering that stores
Power conversion systems for energy storage Engineering that stores INDRIVETEC Innovative Drive Technologies AG The Company Indrivetec specialises in development and manufacture of high-performance storage
More informationPOWERSTRIP SOLAR HEATING
HOT SUN INDUSTRIES INC. NOVEMBER 2013 www.h2otsun.com POWERSTRIP SOLAR HEATING 2013 CATALOG Solar swimming pool heating systems Solar hot water heating systems Web based controls and monitoring Components
More informationProduct Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control
GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional
More informationImplications of Digital Control and Management for a High Performance Isolated DC/DC Converter
MPM-07:000199 Uen Rev A Implications of Digital Control and Management for a High Performance Isolated DC/DC Converter March 2007 Technical Paper Digital control implemented in an isolated DC/DC converter
More informationInterruption Technology of Breakers for High-voltage Direct Current
Interruption Technology of Breakers for High-voltage Direct MORIAI Hiroshi ABSTRT Applications for direct current () electric distribution have been spreading along with the increase of data centers and
More informationWG5Kxxx Modular DC-converter system
Short description WG5Kxxx Modular DC-converter system General characteristics The modular DC converter system is useful for the DC coupling of various electrical components (sources, sinks, storages) with
More informationDEPARTMENT OF THE ARMY TECHNICAL MANUAL DEPARTMENT OF THE AIR FORCE TECHNICAL ORDER TECHNICAL MANUAL
DEPARTMENT OF THE ARMY TECHNICAL MANUAL DEPARTMENT OF THE NAVY PUBLICATION DEPARTMENT OF THE AIR FORCE TECHNICAL ORDER * TO-35C2-3-463-4 TECHNICAL MANUAL Organizational, Intermediate (Field) (Direct and
More informationPERFORMANCE SPECIFICATION SHEET BATTERY, STORAGE, AIRCRAFT, MAINTENANCE-FREE, 24-VOLT, 1.5-AMPERE-HOUR
METRIC MIL-PRF-8565/6A (AS) 25 June 2001 SUPERSEDING DOD-B-8565/6(AS) 26 June 1987 PERFORMANCE SPECIFICATION SHEET BATTERY, STORAGE, AIRCRAFT, MAINTENANCE-FREE, 24-VOLT, 1.5-AMPERE-HOUR This specification
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationMKN-DSP SERIES - THREE PHASE
Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /
More informationBattery Cabinet Hardware v1.0
Battery Cabinet Hardware v1.0 Author: Pierluigi Sarti, Technical Lead, Power 1 Scope This specification defines the requirements for a 75KW stand-alone battery cabinet, with 48VDC nominal voltage, self
More informationSentronic D 608 Series and 609 Series
Sentronic D 608 Series and 609 Series Proportional Technology www.asco.com PRESSURE CONTROL: 608/609 SERIES SENTRONIC D Sentronic D Sentronic D is a digitally operated pressure regulator valve. Sentronic
More informationCIPHERING & DECIPHERING UNITS
CIPHERING & DECIPHERING UNITS High throughput Ciphering / Deciphering Unit Telecommand Deciphering Unit HIGH THROUGHPUT CIPHERING / DECIPHERING UNIT Satellite Telecommand / Telemeasure Protection, Spreading
More informationTechnical Specification SENTINEL PRO
Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES
More informationGEO Dual Mode PPU & LEO HEMPT PPU
GEO Dual Mode PPU & LEO HEMPT PPU EPIC Workshop 2018 London 15-17 Oct 1 Presentation Plan Thales Alenia Space in Belgium, previously named ETCA was created in 1963, 54 years' experience in power supplies
More informationImplications of. Digital Control. a High Performance. and Management for. Isolated DC/DC Converter. Technical Paper 003.
Implications of Digital Control and Management for a High Performance Isolated DC/DC Converter Technical Paper 003 March 2007 Digital control implemented in an isolated DC/DC converter provides equal or
More information