Products Under Mandatory Labeling with Self-Declaration of Conformity As required under Republic Act No (Consumer Act) HOUSEHOLD APPLIANCES
|
|
- Brooke Skinner
- 5 years ago
- Views:
Transcription
1 Products Under Mandatory Labeling with Self-Declaration of Conformity As required under Republic Act No (Consumer Act) The following are the required information to be included in the label common to products in this list: 1. Tradename/Brandname 2. Trademark 3. Model or type 4. Name and address of importer or manufacturer 5. Country of manufacture 6. Direction for use, where applicable HOUSEHOLD APPLIANCES Image Additional Labeling Requirements Title Scope of CoC Sampling 1 Air conditioners 396-1: Energy Efficiency Ratio 2. Cooling capacity in kilojoules per hour 3. Rated voltage in volts 4. Rated current in amperes 5. Power input in watts 6. Rated frequency in hertz 7. Number of phase e.g. single-phase or three-phase Household appliances - Energy efficiency ratio (EER) and labeling requirements - Part 1 : Non-ducted airconditioners Window & Split-type (wall & floor mounted) up to 36,000 KJ/hr cooling capacity 1 unit per model 2 Refrigerators 396-2:1997 Amd. 01: Energy efficiency factor in liters per kilowatt hour 2. Total storage volume in liters 3. Rated voltage in volts 4. Rated current in amperes 5. Energy consumption in kilowatt hour 6. Rated frequency in hertz 7. Rated power input in watts Household appliances - Energy efficiency factor (EEF) and labeling requirements - Part 2 : Refrigerators and freezers Storage volume: 142 liters to 227 liters (5 to 8 cu. ft.) only 1 unit per model 1 of 6
2 LAMPS AND RELATED PRODUCTS Reference Image Additional Labeling Requirements Title Scope of CoC Sampling 3 Ballast (Preheat, Magnetic & Electronic) :2007 IEC 60921: ) IEC 60929: ) 1. Ballast efficacy factor 2. Total power input in watts 3. Rated supply voltage or voltage range 4. Supply frequency equipment Energy labeling requirements Part 4: Ballast For use with ratings from 10W to 40W for T12, T10, T9, T8 & T5 halophosphate and triphosphate fluorescent lamps with G13 & G5 caps 6 pieces 4 CFL/Selfballasted lamps for general lighting services :2007 IEC 969:2006 (IEC published 1988) 1. Light output in lumens 2. Efficacy in lumens per watt 3. Color appearance 4. Average life in hours 5. Total power input in watts 6. Rated supply voltage or voltage range 7. Supply frequency equipment energy efficiency and labeling requirements Part 2: Self-ballasted lamps for general lighting services Watts: 60W & below Voltage: up to 250V AC Edison screw base E14 & E27 25 pieces 2 of 6
3 Image Additional Labeling Requirements Title Scope of CoC Sampling Fluorescent lamps (Doublecapped) : IEC 60081: ) with IEC 60081:2006 Amd (IEC published 2002 Amd. 02:2003) & IEC 60081:2006 Amd. 03: Amd. 03:2005) 1. Light output in lumens 2. Efficacy in lumens per watt 3. Color appearance 4. Average life in hours 5. Total power input in watts 6. Rated supply voltage or voltage range 7. Supply frequency equipment - Energy efficiency and labeling requirements part 1-1: Double -capped fluorescent lamps Linear fluorescent lamps T12, T8 & T5 halophosphate & triphosphate with G13 & G5 caps, 10W up to 65W, V AC 12 pieces 3 of 6
4 Image Additional Labeling Requirements Title Scope of CoC Sampling Fluorescent lamps (Singlecapped) : IEC 1996) IEC Amd. 01: Amd. 01:1997) & IEC Amd. 02: Amd. 02:2000) & 1. Light output in lumens 2. Efficacy in lumens per watt 3. Color appearance 4. Average life in hours 5. Total power input in watts 6. Rated supply voltage or voltage range 7. Supply frequency equipment Energy labeling requirements Part 1-2: Single-capped fluorescent lamps Circular fluorescent lamps 12 pieces IEC Amd. 03: Amd. 03:2004) 4 of 6
5 CONSTRUCTION PRODUCTS Image Additional Labeling Requirements Title Scope of CoC Sampling 5 Ceramic Tiles ISO 13006:2007 with Amd. 01: Mark to indicate quality i.e. Class A, Class B 2. Type of tile and reference to the appropriate annex in the international standards i.e wall tiles, floor tiles 3. Nominal and work sizes, modular (M) or non-modular 4. Nature of the surface, i.e. glazed (GL) or unglazed (UGL) 5. The method of shaping Ceramic Tiles Definitions, Classification, Characteristics & Markings Ceramic Tiles 30 pieces per type 6 Flat Glass 193: Thickness 2. Type and Class Flat Glass - Type I (Transparent) Type II (Patterned and Wired) 4 pieces equivalent sheet 7 upvc rigid electrical conduit 14:1983 Amd. 01: Application (Electrical conduit/thinwall or thickwall) 2. Nominal outside diameter in mm Unplasticized polyvinyl chloride (upvc) electrical conduit Thick wall and thin wall pipes 3 pieces by 1.2 meters per type 5 of 6
6 Image Additional Labeling Requirements Title Scope of CoC Sampling 8 Plywood 196: Type of Plywood 2. Class 3. Thickness 4. Moisture Content Plywood Type I & II plywood products and blackboard, strip boards 10 panels (top, middle, bottom) per type 9 Steel sheets for roofing 67: Coating designation 2. Thickness, in mm 3. Width, in mm 4. Date of manufacture (month and year) 5. The term FOR ROOFING USE 6. Estimated service life Hot-dipped metalliccoated steel sheets for roofing - Hot-dipped metallic steel sheets for roofing 3 units (top, middle, bottom) per type 10 Steel wires (low carbon) 113: Zinc-coating base: (class 1, 2, 3, 4) 2. Process (electrolytic or hot-dipped galvanized) 3. Wire diameter 4. Net weight per coil, in kilogram 5. Date of manufacture Low carbon steel wires plain, annealed & galvanized - Steel wires 3 pieces by 2 meter length 11 Wire nails 136: Length and diameter, in mm 2. Net weight, 25 kg per box 3. Year and date of manufacture 4. The number of standard, 136 Steel - Wire nails Common nails and finishing nails 1 kilo per type 6 of 6
Lessons Learned in Lighting Equipment Testing in the Philippines
Lessons Learned in Lighting Equipment Testing in the Philippines Engr. Arturo M. Zabala, PEE Fuels and Appliance Testing Laboratory DEPARTMENT OF ENERGY Lessons Learned in Asia: Regional Symposium on Energy
More informationStandards, Regulations and Labelling Requirements for Lighting Products Irosha S. Kalugalage
Standards, Regulations and Labelling Requirements for Lighting Products Irosha S. Kalugalage Sri Lanka Sustainable Energy Authority Content of Presentation 2 Lighting Products with National Standards in
More informationLEGISLATIVE FRAMEWORK
PHILIPPIN I. RATIONAL FOR RGULATION COUNTRY RATIONAL FOR RGULATION Philippines Upgrade the quality of products. Protect and safeguard the interest of consumers especially in matters of health and safety.
More informationORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL
PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL Order in Council No. 089, Approved and Ordered March 6, 2018 Executive Council Chambers, Victoria Lie~ Governor On the recommendation
More informationHigh Efficiency Lighting units
High Efficiency Lighting units Current Eligibility Criteria Various combinations of Lighting Fitting with Associated Control Gear and Lamp(s) meet the criteria for a High Efficiency lighting Unit. For
More informationSHEDULE 1(A) Serial No. Serial No. HS Codes Article Column III Article Column IV. HS Codes Article Column III Article Column IV
SHEDULE 1(A) 1 0402.21 0402.10 0402.29 2 0402.99.10 0402.99.90 Full Cream Milk Powder Low Fat Milk Powder Non-Fat (Skimmed) Milk Powder Condensed Milk SLS 731 Specification for Milk Powder SLS 179 Specification
More informationLighting Tables for New Equipment 2/24/2015
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---
More informationASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES
ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,
More informationLighting Tables for New Equipment 3/9/2016
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION
More informationTable 3:List of Mandatory Omani Standards
2/3/1978 6/99 1/1977 - Precast concrete blocks 2/1982 - Aggregates from natural sources for concrete 3/1977 777/1997 Cement flooring tiles and wood base materials 4/1978 - Building sands from natural sources.
More informationN2XY IEC XLPE PVC 0.6/1kV Cable
N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to
More informationLE Fluorescent Ballast
HF-PERFORMER II Electronic ballasts (flat) for TL5 lamps Definition Flat, Slim, lightweight highfrequency electronic ballast for TL-5 fluorescent lamps, based on EII technology. Description The combination
More informationCELMA Guide for the application of the Commission Regulation (EC) No. 245/2009 on Tertiary lighting sector products
Federation of National Manufacturers Associations for Luminaires and Electrotechnical Components for Luminaires in the European Union CELMA Guide for the application of the Commission Regulation (EC) No.
More informationLighting Tables for New Equipment 1/1/2018
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
17065:2012 to provide product conformity certification 1, Place des Alpes CH-1211 Geneva Switzerland Contact: Patricia Lumbreras Tel: +(511) 221 1159 E-Mail: patricia.lumbreras@sgs.com Locations where
More informationOkSolar LED Outdoor Luminaires
OkSolar 488500 LED Outdoor Luminaires 1.0 PURPOSE The purpose of this specification is to provide the minimum performance requirements for the LED Outdoor Luminaire Fixture. This specification refers to
More informationLighting Tables for Existing/Base Equipment 4/15/2011
T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031
More information2017/SOM3/SCSC/JRAC/010 Agenda Item: 6a
2017/SOM3/SCSC/JRAC/010 Agenda Item: 6a Mutual Recognition Arrangement on Conformity Assessment of Electrical and Electronic Equipment - APEC EEMRA Information Interchange Format Part 1 Thailand Purpose:
More informationCentral Battery Systems
Central battery system based emergency lighting is ideal for medium to large installations. For projects where central control and testing is desirable, a central battery system is a viable and cost effective
More informationT5 Watt-Miser Linear Fluorescent lamps
GE Lighting T5 Watt-Miser Linear Fluorescent lamps DATA SHEET T5 Watt-Miser High Efficiency 14W, 21W, 28W, 35W T5 Watt-Miser High Output 24W, 39W, 49W, 54W, 80W Product information T5 Watt-Miser lamps
More informationLED Tubes Dimmable SMD technology and specs
U. S. W Y LED Tubes 2010 Dimmable SMD technology and specs First LED tubes tested and listed by: UL 1993 Standard ISO9001:2000 ISO14001:2004 For the most affordable prices, please contact the U.S.WAY Lighting
More informationCentral Battery Systems
Central battery system based emergency lighting is ideal for medium to large installations. For projects where central control and testing is desirable, a central battery system is a viable and cost effective
More informationAmendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts
Revision 1 Date: 28/01/2016 Amendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts In the said schedule, (i) in paragraph 7, for sub-paragraph (i) the following shall be substituted,
More informationUsing Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.
Using Electricity Summary Notes Section Content 1. From the Wall Socket Household appliances. Earth wire and safety. 2. Alternating and Direct Battery and transformer. Current Circuit diagrams. Current
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61325 First edition 1995-03 Insulators for overhead lines with a nominal voltage above 1 000 V Ceramic or glass insulator units for d.c. systems Definitions, test methods and
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationUNEP en.lighten program: Pacific Regional Status Report. GEORGE WILKENFELD & ASSOCIATES Regional Efficient Lighting Meeting Fiji September 22, 2014
UNEP en.lighten program: Pacific Regional Status Report GEORGE WILKENFELD & ASSOCIATES Regional Efficient Lighting Meeting Fiji September 22, 2014 AIMS REGIONAL LIGHTING STATUS REPORT Review lighting patterns
More informationEfficient fluorescent lighting with improved color rendering
Lighting Efficient fluorescent lighting with improved color rendering The lamp offers more lumens per watt and better color rendering than TL-D standard colors. Furthermore, it has a lower mercury content.
More informationINTERACTIVE SCIENCE 2A
INTERACTIVE SCIENCE 2A Workbook Solutions (Enrichment Edition) Chapter 8 MAKING USE OF ELECTRICITY Part A Sectional Exercise 8.1 & 8.2 Concept checking p.35 1. False 2. True 3. False 4. True 5. True Questions
More informationP6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units
TM TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-2-3382-8 Edition 3.2 and IEC corr. 1 IEC 0309-1:2012 Edition.2 and corr. 1 SOUTH AFRICAN NATIONAL STANDARD Plugs, socket-outlets and couplers for industrial purposes This national standard is
More informationENVIRONMENT AND DEVELOPMENT PLANNING ACT (CAP. 504) Waste Management (End of Life Vehicles) (Amendment) Regulations, 2013
B 4223 L.N. 346 of 2013 ENVIRONMENT AND DEVELOPMENT PLANNING ACT (CAP. 504) Waste Management (End of Life Vehicles) (Amendment) Regulations, 2013 BY VIRTUE of the powers conferred by articles 61and 62
More informationICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical
ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical
More informationToLEDo T8 ToLEDo T8 V4 5FT 27W 2700LM
Image not found. Product features Energy efficient and affordable LED T8 solution to replace conventional fluorescent T8 lamps. Omnidirectional 320 uniform light distribution thanks to glass tube construction
More informationIMPORTS SUBJECT TO SRI LANKA STANDARDS
IMPORTS SUBJECT TO SRI LANKA STANDARDS 0402.10 Skimmed Milk Powder SLS 731:Specification for Milk Powder 0402.21 Full Cream Milk Powder SLS 731:Specification for Milk Powder 0402.29 0402.99.01 Condensed
More informationSo, You re Thinking About Converting to LEDs?
So, You re Thinking About Converting to LEDs? For More Information Please contact: Roberts Research & Consulting, Inc. 3 Garrison Road, Burnt Hills, NY 12027 vic25@robertsresearchinc.com Don t forget to
More informationSeleCCTable LED Direct Mount Collection. RL Recessed Downlight. Direct Mount
SeleCCTable LED Direct Mount Collection RL Recessed Downlight Direct Mount HALO SeleCCTable Family 2700K 3000K 3500K 4000K 5000K RL-DM SeleCCTable Series RL4069S1EWHDM 4 LED Retrofit Baffle-Trim, Direct
More informationP4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units
TM TECHNICAL SPECIFICATIONS P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units The P4 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationHU20 Undercabinet lighting
HU20 Undercabinet lighting HU20 Magnetic Puck LED Undercabinet Halo introduces the next generation of HU20 to address your LED Undercabinet and task lighting needs. Ideal for task, accent, office, cove,
More informationASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES
ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,
More informationVolume 2 Charts, Formulas, and Other Useful Information
Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase
More information31-SDMS-02 REV. 01 SPECIFICATIONS FOR
31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P
More informationASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES
ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,
More informationShatterfree fluorescent lighting
Shatterfree fluorescent lighting MASTER TL5 HE Secura This TL5 High Efficiency Secura lamp (tube diameter 16 mm) has a protective coating that keeps glass and lamp components together in the event of accidental
More information4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.
CHAPTER 17 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?
More informationUF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 UF103WG250 10/3 WG Uf Cable-250' Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category
More informationMN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012
1. LISTING REQUIREMENTS MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL) as defined by the U.S.
More informationM OTO R. The electric motor. DC - direct current voltage.
TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily
More informationGQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS GQ4SD Series Single Packaged Heat Pump 13 SEER The GQ4 Series single packaged units are high efficiency self contained cooling and heating units that can be installed on a roof
More informationOverhead transmission lines Tension clamp
SVENSKA KRAFTNÄT T~ SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AFL, Asset Management Lines OUR REFERENCE TR05-06E DATE 2016-06-09 CONSULTÅTIONS m /j(j TECHNICAL GUIDELINE REVISION 3 Td APPROVED Overhead
More informationELECTRONIC FLUORESCENT BALLASTS
ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts AmbiStar SmartMate Standard T5HO PureVOLT 1 Lighting s Atlas -11 ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts Fluorescent allasts - - High-efficiency
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-29808-1 SOUTH AFRICAN NATIONAL STANDARD Kerosene for domestic heating and illuminating WARNING This standard references other documents normatively. Published by SABS Standards Division
More informationEnergy Storage. Electrochemical Cells & Batteries
Energy Storage These notes cover the different methods that can be employed to store energy in various forms. These notes cover the storage of Electrical Energy, Kinetic Energy, and Pneumatic Energy. There
More informationMOTOR. The electric motor. DC - direct current voltage.
TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily
More informationElectrical power. Objectives. Assessment. Assessment. Equations. Physics terms 5/27/14
Electrical power Objectives Use the equation for electrical power to solve circuit problems. Understand basic concepts for home electricity usage and wiring. Calculate the power used by electric circuit
More informationLighting Tables for Existing/Base Equipment 4/15/2011
T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031
More information483 mm (19 ) Server Cabinet Unique Series. Abstract. Features. 1.5 mm strong steel sheet. Load capacity up to 1000 kg. Standard colors grey and black
483 mm (19 ) Server Cabinet Unique Series 1.5 mm strong steel sheet Load capacity up to 1000 kg Standard colors grey and black Large range of equipment available DN-19 SRV-42U-8/12 Abstract 483 mm (19
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationLighting Tables for Existing/Base Equipment 1/1/2014
T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO
More informationMay 13, 2008 Physics - Electricity & Magnetism. Title: Hot Dog Circuits Demonstration 1. Abstract:
May 13, 2008 Physics - Electricity & Magnetism Title: Hot Dog Circuits Demonstration 1 Abstract: This demonstration is a way to help students understand Ohm's Law and relationships between power and current.
More informationNema Head We light your world
Nema Head We light your world 03.15.18 THD 80 PF >.95 10kV Surge Protector + 5-40 C~50 C 35,000 Warranty YEAR LED Nema Head 44w/65w Advances in LED technology allow us to create
More informationElectrical Energy and Power Ratings
Section 1 - From the Wall Socket Electrical Energy and ower Ratings Batteries and the mains are sources of electrical energy. Electrical appliances can then convert this into other forms of energy. e.g.
More informationSeleCCTable LED Direct Mount Collection
SeleCCTable LED Direct Mount Collection HLB Ultra-thin Recessed Downlight HALO HLB ultra-thin The HLB is an ultra-thin LED lens downlight with a remote driver / junction box ideal for new construction
More informationQTi DALI/DIM / QTi GII / QTP5
osram.com LUMILUX T5 HO High Lumen Output LUMILUX T5 HO QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01 Benefits Impressive luminous flux High efficiency Very good luminous flux maintenance throughout
More informationA R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S
T A B L E O F C O N T E N T S A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S WL700R - Wall Luminaire with Open Faceplate G2.1 WL730R - Wall Luminaire with Cross Bar G2.2 WL755R - Wall Luminaire
More informationAnthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A
Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A 99-16999-0000 Table of Contents 1. Removing Fluorescent Lighting... 4 1.1. Detach the lens assembly... 4 1.2. Remove
More informationDEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016
Trade and Industry, Department of/ Handel en Nywerheid, Departement van 438 National Regulator for Compulsory Specifications Act (5/2008): Amendments to the Compulsory Specification for Earth Leakage Protection
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SE Series M1200 Product Line Single Packaged Heat Pump 14 SEER - 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE - 12 YEAR
More informationSKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition
Annex J - Specific requirements for PVT collector Certification 1. Introduction and definition PVT collectors (named hybrid collectors in ISO 9806) generate heat and electric power at the same time. They
More information34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise
DirectAC UNV Retrofit Kit Engines Integrated AC Direct Drive (No DC Driver) culus Classified 1598C Universal Voltage (10~77) AC Engine culus Recognized 8750 Suitable for open or fully enclosed luminaires
More informationVMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT
5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded
More informationPerformance Rating of Single Package Vertical Air-Conditioners And Heat Pumps
ANSI/AHRI Standard 390 2003 Standard for Performance Rating of Single Package Vertical Air-Conditioners And Heat Pumps IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60884-1 Edition 3.1 2006-07 Edition 3:2002 consolidated with amendment 1:2006 Plugs and socket-outlets for household and similar purposes Part 1: General requirements IEC 2006
More informationLED. High-performance streetlight. -afortable and reliable
LED High-performance streetlight -afortable and reliable DESIGNED FOR FUNCTIONAL LIGHTING OF OUTDOOR ROADS WHERE ENERGY SAVING, LOW MAINTENANCE AND PRECISE LIGHT CONTROL CONSIDERATIONS ARE IMPORTANT FACTORS.
More informationEdition Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.
osram.com Reduce up to 10% of Energy usage even in existing systems QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01 Benefits Energy savings up to 10% compared to standard T5 HO lamps Good economy
More informationUnderstanding Electrical Terms
Understanding Electrical Terms Complimentary brochure from Understanding Electrical Terms In today s computer-intensive work environments, a critical issue is clean, reliable power. Powerlite is the industry
More informationLUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.
WSV600 Wall Luminaire with Open faceplate 2007.4.13 Applications: Oval Surface Wall Sconce Luminaires are ideal for indoor or outdoor applications in, residential, commercial, or architectural installations
More informationTMU140055CL8xxA 44 LINEARHO DC MODULE, 1400mA MAX CURRENT
44 LINEARHO DC MODULE, 1400mA MAX CURRENT For use in UL Class 2 lighting systems Suitable for DLC Applications: L70 >60,000hrs/L90 40,000hrs Meets UL8750 Recognized Compliant Extruded Aluminum material
More informationVMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT
22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded
More informationA direct current (DC) circuit. L 26 Electricity and Magnetism [4] Alternating Current (AC) Direct Current DC. AC power
L 26 Electricity and Magnetism [4] A direct current (DC) circuit simple electrical circuits direct current DC Alternating current (AC) vs direct current (DC) electric power distribution household electricity
More informationLinear Replacement Lamps
Linear Replacement Lamps PLEASE NOTE: DLC DEFINES ALL TUBE-STYLE LED PRODUCTS THAT USE THE LAMP HOLDERS (I.E. SOCKETS OR TOMBSTONES ) IN THE LUMINAIRE TO MECHANICALLY OR ELECTRICALLY CONNECT TO THE FIXTURE
More informationTMU125050CL8xxA 22 LINEARHO DC MODULE, 1250mA MAX CURRENT
22 LINEARHO DC MODULE, 1250mA MAX CURRENT For use in UL Class 2 lighting systems Suitable for DLC Applications: L70 >60,000hrs/L90 40,000hrs Meets UL8750 Recognized Compliant Extruded Aluminum material
More informationScience 10-Electricity & Magnetism Activity 12 Worksheet on Electrical Energy and Power
Science 10-Electricity & Magnetism Activity 12 Worksheet on Electrical Energy and Power Name Due Date Show Me Hand In 20 Correct and Hand In Again By Note: Information for this worksheet can be found on
More informationSouthwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper
More informationVMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT
46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded
More informationVMU240095LP8xxA 44 LP-LINEARHO DC MODULE, 2400mA MAX CURRENT
44 LP-LINEARHO DC MODULE, 2400mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded
More information12.7 Power in Electric Circuits
1.7 1.7 Power in Electric Circuits To predict the amount of energy used by an electrical device, such as a radio, stove, lights, or television, we first need to know the amount of time the device will
More informationARAI Date of hosting on website: 27 th October 2015 Last date for comments: 27 th November 2015
ARAI Date of hosting on website: 27 th October 2015 Last date for comments: 27 th November 2015 CHECK LIST FOR PREPARING AMENDMENT TO AUTOMOTIVE INDUSTRY STANDARD (AIS) Draft Amd. No 01 to AIS-099 : Approval
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More informationHOW IS LIGHT PRODUCED
HOW IS LIGHT PRODUCED The fluorescent lamp produces light by the passage of an electric current flowing through a vapor of mercury. 1.Electron emitted from electrode collides with mercury atom. 2.Impact
More informationLSW9 Hydraulic lighting tower
LSW9 Hydraulic lighting tower The LSW9 is a compact trailer-mounted light tower with a narrow design thought for cost-effective transportation and storage. It is equipped with a 9 meter adjustable with
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION IEC TS 62735-1 Edition 1.0 2015-08 colour inside Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres
More informationELECTRONIC FLUORESCENT BALLASTS
ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic
More informationANNEX B TECHNICAL SPECIFICATIONS PORTABLE SOLAR-POWERED LIGHTS
ANNEX B TECHNICAL SPECIFICATIONS PORTABLE SOLAR-POWERED LIGHTS ITB/2017/869 1 GENERAL SPECIFICATION 1. There shall be 2 categories of lights for evaluation under this tender : A. With Mobile Device Charging
More informationProduct Submittals for Project
Product Submittals for Project May 011-1 Couplings Figure 577 Light Weight Rigid Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building
More informationLANCE-KASHIAN & COMPANY River Park Plaza Parking Lot Lighting Retrofit Fresno, CA May 21, 2013
LANCE-KASHIAN & COMPANY River Park Plaza Fresno, CA May 21, 2013 Project Overview On May 21 th 2013, USIGT, in conjunction with D5 Enterprises, retrofitted the existing High Pressure Sodium (HPS) parking
More informationShatterfree fluorescent lighting
Shatterfree fluorescent lighting MASTER TL-D This TL-D lamp has a protective coating that keeps glass and lamp components together in the event of accidental breakage. The lamp is easily identifiable by
More informationPVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper
THHN/THWN-2/MTW/T90 PVC Insulation with Nylon Jacket Solid or Stranded Soft-annealed Uncoated Copper Specifications ASTM (American Society for Testing & Material ASTM B3 Class B, B8 (sizes 6 and larger),
More informationPart 11: Wheelchairs. Test dummies
INTERNATIONAL STANDARD ISO 7176-11 Second edition 2012-12-01 Wheelchairs Part 11: Test dummies Fauteuils roulants Partie 11: Mannequins d essai Reference number ISO 2012 COPYRIGHT PROTECTED DOCUMENT ISO
More informationGP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS GP5RD Series Single Packaged Air Conditioner, Single Phase GP5RD-13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 60,000 Btuh The GP5 Series single packaged air conditioners
More information