1 Your Peace of Mind is Our Top Priority Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX Louisville, KY SHIP TO: 3649 Cane Run Road Louisville, KY (502) (800) 928-PUMP FAX (502) visit our web site: SECTION: Z ZM Supersedes New REPLACEMENT PARTS LIST FOR 7011 GRINDER E V 1 PHASE I V 1 PHASE F V 3 PHASE G V 3 PHASE J V 3 PHASE BA V 3 PHASE TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION: Model Number. Part Number of Pump. Part Number and Description of part. POWER CORD SENSOR CORD (CORD MAY BE 4 OR 5 CONDUCTOR) (WITH OR WITHOUT GROUND) (GREEN GROUND WIRE CLIPPED FLUSH TO OUTER JACKET) POWER CORD SENSOR CORD (CORD MAY BE 4 OR 5 CONDUCTOR) (WITH OR WITHOUT GROUND) (GREEN GROUND WIRE CLIPPED FLUSH TO OUTER JACKET) * L1 L2 L3 GRD COVER BLACK RED ORANGE BLUE GREEN GREEN RED ORANGE BLACK COVER BLACK RED GREEN GREEN RED ORANGE BLACK T1 T2 M1 M T1 T2 M1 M T1 T2 M1 M T1 T2 M1 M2 MOTOR /BLACK TRACER /RED TRACER /RED TRACER /BLUE TRACER THERMOSTAT MOTOR BLACK OR BLUE BROWN OR TAN OR ORANGE THERMOSTAT OVERLOAD AUXILIARY WINDING MAIN WINDING MOTOR BLACK OR /BLACK TRACER BLACK OR /BLACK TRACER WINDINGS MOTOR BLACK OR /BLACK TRACER BLACK OR /BLACK TRACER SEAL SENSOR FAILURE PROBES 330K OHMS RESISTANCE SEAL SENSOR FAILURE PROBES 330K OHMS RESISTANCE (BEFORE 6/2000 N/O) (BEFORE 6/2000 N/O) *Thermostat Optional WIRING DIAGRAM FOR MODELS E7011 All Revisions I7011 All Revisions 1 WIRING DIAGRAM FOR MODELS F7011 All Revisions G7011 All Revisions J7011 All Revisions BA7011 All Revisions
2 REPLACEMENT PARTS LIST FOR MODELS E7011 E7011-A 1 COVER & CORD 200/230V/1PH GRINDER HOUSING,MTR-& STR 230V/1PH OIL,DIELECTRIC-(57 OZ CAN) ROTOR ASM 200/230V/1PH CORDAGE TERM&SEAL/ SEAL,CORD-ASM CORDAGE TERM&SEAL/ IMPELLER-MACH HOUSING,PUMP-MACH SCREW, X 1 LG HH SS (NYLOCK PRE-COAT 80) RESISTOR REBUILD KIT ) Housing, MTR & Stator (Item 4) is preassembled at factory and must be replaced as a unit. Stator is permanently attached to the Motor Housing. Plug (Item 14) and Seal, Wall Term. (Item 3) are replaceable. 2
3 REPLACEMENT PARTS LIST FOR MODELS I7011 I7011-A 1 COVER & CORD 200/230V/1PH GRINDER HOUSING,MTR-& STR 200V/1PH OIL,DIELECTRIC-(57 OZ CAN) ROTOR ASM 200/230V/1PH CORDAGE TERM&SEAL/ SEAL,CORD-ASM CORDAGE TERM&SEAL/ IMPELLER-MACH HOUSING,PUMP-MACH RESISTOR REBUILD KIT ) Housing, MTR & Stator (Item 4) is preassembled at factory and must be replaced as a unit. Stator is permanently attached to the Motor Housing. Plug (Item 14) and Seal, Wall Term. (Item 3) are replaceable. 3
4 REPLACEMENT PARTS LIST FOR MODELS F7011 F7011-A 1 COVER & CORD 200/230/460/575V/3PH GRINDER HOUSING,MTR-& STR 230V/3PH OIL,DIELECTRIC-(67 OZ CAN) ROTOR ASM 200/230/460/575V/3PH CORDAGE TERM&SEAL/ SEAL,CORD-ASM/SENSOR CD CORDAGE TERM&SEAL/ IMPELLER-MACH HOUSING,PUMP-MACH RESISTOR REBUILD KIT CONDUCTOR SENSOR CORD ) Housing, MTR & Stator (Item 4) is preassembled at factory and must be replaced as a unit. Stator is permanently attached to the Motor Housing. Plug (Item 14) and Seal, Wall Term. (Item 3) are replaceable. 4
5 REPLACEMENT PARTS LIST FOR MODELS G7011 G7011-A 1 COVER & CORD 200/230/460/575V/3PH GRINDER HOUSING,MTR-& STR 460V/3PH OIL,DIELECTRIC-(67 OZ CAN) ROTOR ASM 200/230/460/575V/3PH CORDAGE TERM&SEAL/ SEAL,CORD-ASM/SENSOR CD CORDAGE TERM&SEAL/ IMPELLER-MACH HOUSING,PUMP-MACH RESISTOR REBUILD KIT CONDUCTOR SENSOR CORD ) Housing, MTR & Stator (Item 4) is preassembled at factory and must be replaced as a unit. Stator is permanently attached to the Motor Housing. Plug (Item 14) and Seal, Wall Term. (Item 3) are replaceable. 5
6 REPLACEMENT PARTS LIST FOR MODELS J7011 J7011-A 1 COVER & CORD 200/230/460/575V/3PH GRINDER HOUSING,MTR-& STR 200V/3PH OIL,DIELECTRIC-(67 OZ CAN) ROTOR ASM 200/230/460/575V/3PH/ CORDAGE TERM&SEAL/ SEAL,CORD-ASM/SENSOR CD CORDAGE TERM&SEAL/ SEAL,SQ-RING SEAL PLATE IMPELLER-MACH HOUSING,PUMP-MACH RESISTOR REBUILD KIT 5 CONDUCTOR SENSOR CORD ) Housing, MTR & Stator (Item 4) is preassembled at factory and must be replaced as a unit. Stator is permanently attached to the Motor Housing. Plug (Item 14) and Seal, Wall Term. (Item 3) are replaceable. 6
7 REPLACEMENT PARTS LIST FOR MODELS BA7011 BA7011-A 1 COVER & CORD 200/230/460/575V/3PH GRINDER HOUSING,MTR-& STR 575V/3PH 1 4, OIL,DIELECTRIC-(67 OZ CAN) ROTOR ASM 200/230/460/575V/3PH CORDAGE TERM&SEAL/ SEAL,CORD-ASM/SENSOR CD CORDAGE TERM&SEAL/ SEAL,CORD-ASM ADAPTER ASM GRINDER PLATE,SEAL-MACH IMPELLER-MACH HOUSING,PUMP-MACH RESISTOR REBUILD KIT CONDUCTOR SENSOR CORD ) Housing, MTR & Stator (Item 4) is preassembled at factory and must be replaced as a unit. Stator is permanently attached to the Motor Housing. Plug (Item 14) and Seal, Wall Term. (Item 3) are replaceable. 5) When ordering these parts, customer must identify if G.E. or EMD. 6) When ordering this part, customer must determine if an adapter with wings is required and specify when placing order. 7
8 REPLACEMENT PARTS ILLUSTRATION FOR ALL MODELS OR "WINGS" ARE APPLICABLE FROM 11/93 TO 08/ SK1382 8
TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION: Model Number. Part Number of Pump. Part Number and Description of part.
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 37 Louisville, KY 025-037 SHIP TO: 39 Cane Run
More informationTO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION: Model Number. Part Number of Pump. Part Number and Description of part.
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 37 Louisville,
More informationConsult factory for all other models TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION:
Your Peace of Mind is Our Top Priority Product information presented of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: SHIP TO: visit our web site: www.zoeller.com SECTION:
More informationREPLACEMENT PARTS LIST FOR MODELS:
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationConsult factory for all other models TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION:
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationREPLACEMENT PARTS LIST FOR GRINDER MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 17 Louisville, KY 025-07 SHIP TO: 9 Cane Run
More informationREPLACEMENT PARTS LIST FOR GRINDER MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 17 Louisville, KY 025-07 SHIP TO: 9 Cane Run
More informationREPLACEMENT PARTS LIST FOR MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationREPLACEMENT PARTS LIST FOR MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 364
More informationREPLACEMENT PARTS LIST FOR GRINDER MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 17 Louisville, KY 025-07 USA SHIP TO: 9 Cane
More informationREPLACEMENT PARTS LIST FOR MODELS: M161 AUTOMATIC 115V D161 AUTOMATIC 230V N161 NONAUTOMATIC 115V E161 NONAUTOMATIC 230V
Your Peace of Mind is Our Top Priority Product information presented of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: SHIP TO: visit our web site: www.zoeller.com SECTION:
More informationREPLACEMENT PARTS LIST FOR MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 634 Louisville, KY 40256-034 SHIP TO: 3649 Cane
More informationL2 BLACK SWITCH COM RELAY LS R S L WHITE RED BLUE BLUE RED MOTOR O.L. START RUN
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 1634
More informationREPLACEMENT PARTS LIST FOR MODELS:
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 1634
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationOWNER S MANUAL MODEL 404/4404 AND
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationREPAIR MANUAL CAUTION
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 647 Louisville, KY 4056-047 SHIP TO: 649 Cane
More informationTurbine STEP System SIMPLEX OR DUPLEX
3649 Cane Run Road Louisville, KY 211-1961, USA 1-800-928-7867 1-502-778-2731 Fax: 1-502-774-3624 www.clarusenvironmental.com SECTION: C1.20.120 CL0019 0816 Supersedes 1212 Turbine STEP System SIMPLEX
More information50/60 Hz REPAIR MANUAL 61 HD SERIES HEAVY-DUTY SOLIDS HANDLING PUMPS. Table of Contents. Safety Instructions. To Order Replacement Parts
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationQWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.065 Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication.
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationOWNER S MANUAL 71 SERIES SUBMERSIBLE GRINDER UNITS SAFETY INSTRUCTIONS TABLE OF CONTENTS OWNER S INFORMATION. visit our web site:
Notice to installer: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationSPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationREPAIR MANUAL 71 SERIES SUBMERSIBLE GRINDER UNITS
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here re flects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationQWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.064 Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication.
More informationOWNER S MANUAL 6680 SERIES SUBMERSIBLE NON-CLOG UNITS
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationPREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationREPAIR MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS CAUTION
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationSPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationOWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationDRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Notice to Installer: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationOWNER S MANUAL 62 HD SERIES SUBMERSIBLE NON-CLOG UNITS. Table of Contents. Safety Instructions. Owner s Information
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationS MANUAL 61 HD SERIES SUBMERSIBLE NON-CLOG UNITS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. Register your Zoeller Engineered Product on our website: http://reg.zoellerengprod.com/
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 1637 Louisville, KY 06-037 SHIP TO: 369 Cane
More informationS MANUAL 64 HD SERIES SUBMERSIBLE NON-CLOG UNITS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. Register your Zoeller Engineered Product on our website: http://reg.zoellerengprod.com/
More informationCAUTION PREINSTALLATION CHECKLIST. visit our web site: Your Peace of Mind is Our Top Priority. Section: 6.10.
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationOWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Safety Instructions. Table of Contents. Owner s Information
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More information12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More information12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationDRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131
Notice to Installer: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationOWNER S MANUAL Commercial Duty Pumps
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. Register your Zoeller Engineered Product on our website: http://reg.zoellerengprod.com/
More informationMODEL 510 THE BASEMENT SENTRY II 12 VOLT DC BACKUP PUMP
NOTICE TO INSTALLER: Instructions must remain with Installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationMODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC
4V, 4R, 4VH, 6VH 4VC, 6VC MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with GE motor. NOTE! To the installer: Please make sure you
More information50 Hz Products. Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories. Trusted. Tested. Tough.
Hz Products Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories Trusted. Tested. Tough. WHAT SETS ZOELLER PUMPS APART? Since 199, Zoeller Company has been manufacturing
More informationOWNER S MANUAL MODELS 810 & 815 PROGRESSING CAVITY GRINDER PUMPS
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationMODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationOWNER S MANUAL X71 HAZARDOUS ENVIRONMENT SERIES CLASS I, DIVISION 1, GROUP C & D SUBMERSIBLE GRINDER UNITS CAUTION
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationREPAIR MANUAL 69 HD SERIES HEAVY DUTY SOLIDS HANDLING PUMPS. Safety Instructions. Table of Contents. To Order Replacement Parts. Short Term Storage
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationMPE 750 Turbo Marine - Closed Loop
- This spare parts catalogue is valid for the following engine variants: Document No: 00 ETK Revision: 00_I MAR TC- DS V 00.. Date of Issue:.0.00 Table of Contents 00 Crankcase 0 Case 0 Front Cover 00
More informationMPE 750 Turbo Marine - Open Loop
- This spare parts catalogue is valid for the following engine variants: Document No: 00 ETK Revision: 00_MPE 0 Marine SO.. Date of Issue: 0.0.00 00_ETK_Rev._000 Table of Contents 00 Crankcase 0 Case 0
More informationSPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001
Performance SPD50H/100H RPM: 3450 Discharge: 2" Solids: 3/4" Wholesale Products Page: 6130-1 Section: Performance Dated: April 2002 Supersedes: January 2001 SPD50H SPD100H The curves reflect maximum performance
More informationMPE 750 Turbo Marine - Open Loop
- This spare parts catalogue is valid for the following engine variants: Document No: 00 ETK Revision: 00_MPE 0 Marine SO.. Date of Issue: 0.0.00 00_ETK_Rev._000 Table of Contents 00 Crankcase 0 Case 0
More informationPOLYPROPYLENE PUMP TUBE SP-PP SERIES
POLYPROPYLENE PUMP TUBE SP-PP SERIES * * * 0 * V-seal - Viton Pump coupling Drive shaft, " (00 mm) Discharge housing Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can
More informationGR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)
U.S.A. 505 Woodland Rd., Mt. Pocono, PA 18344 Phone: (570) 851-0075 Fax: (570) 216-4570 www.grinderpumpsusa.com sales@grinderpumpsusa.com GRINDER PUMPS GPU2-21 2 HP Grinder Pump 2 Piece Motor Housing
More informationGR NDER PUMPS. Technical Catalog
Technical Catalog GR NDER PUMPS U.S.A. 505 Woodland Rd., Mt. Pocono, PA 18344 Phone: (570) 851-0075 Fax: (570) 216-4570 www.grinderpumpsusa.com sales@grinderpumpsusa.com GRINDER PUMPS GPU2-21 1½ HP Grinder
More informationMYERS MODELS 4V AND 4VX
MYERS MODELS 4V AND 4VX SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4V) AND HAZARDOUS LOCATION (4VX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4V AND 4VX Solids Handling Wastewater Pumps The Right Choice
More informationPump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon
Pump Specifications 1100-Series Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon 1100-P1 R2/19/2013 Copyright 2013 Liberty Pumps Inc. All rights reserved. Specifications subject to change without
More informationMYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent
The Myers heavy-duty series pumps are designed for residential raw sewage and light commercial applications. The non-clogging two-vane impeller delivers high-efficiency pumping and easily handles trashy
More informationMYERS MODELS 4R AND 4RX
MYERS MODELS 4R AND 4RX SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4R) AND HAZARDOUS LOCATION (4RX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4R AND 4RX Solids Handling Wastewater Pumps The Right Choice
More informationOWNER S MANUAL MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL FAHRENHEIT SK-F & SKX-F SERIES SHREDDER PUMPS Electric Submersible Pumps
INSTALLATION, OPERATION & MAINTENANCE MANUAL FAHRENHEIT SK-F & SKX-F SERIES SHREDDER PUMPS Electric Submersible Pumps Single Phase 208V & 230V CAST IRON SINGLE PHASE SK1500C-F 316 STAINLESS STEEL SINGLE
More informationHYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT
PERFORMANCE DATA Wholesale Products Page: 6130-1 Supersedes: April 2002 RPM: 3450 Discharge: 2 Solids: ¾ SPD50H SPD100H HEAD-METERS 18 12 6 TOTAL HEAD IN FEET 60 40 20 0 0 Capacity-U.S. G.P.M. SPD50H SPD100H
More informationKW Submersible, Single-Vane Impeller
Sewage Pumps KW Submersible, Single-Vane Impeller Performance Curve Total Head (FT) Up to 2 Solids-Handling Heavy-Duty, Silicon Carbide Seals Stainless Steel Keyed Shaft Flows to 325 GPM / Heads to 95
More informationPotable Water Submersible Turbine Pumps
Notice to installer: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationHYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR
SK75/100 PERFORMANCE DATA Wholesale Products Page: 6300-1 RPM: 1750 Discharge: 2 Solids: 2 12 40 HEAD-METERS 9 6 3 TOTAL HEAD IN FEET 30 20 10 SK75 SK100 0 0 Capacity-U.S. G.P.M. 0 20 40 60 80 100 120
More informationKG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)
Grinder Pumps 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) The KEEN PUMP series centrifugal grinder pumps easily handle residential, commercial or industrial sanitary waste,
More informationOWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationMODEL NO REPAIR PARTS FRAME
FRAME 37 FRAME Key No. Part No. Description 90 198573X479 COVER, BOTTOM 91 198574 SCREW, 1/4--20X.63 103 406364X008 IDLER ASSEMBLY, AUGER 105 198576 PIN, HAIR.38DIAX1.64LG 106 198580 PIN, CLEVIS 3/16 DIA
More informationDI DI PUMP PARTS PRICE LIST
ITEM 1 2 2A 5050 Pump Body, 2" NPT Mech. Seal 1 40091 1 5050 Pump Body, 2" 150# RF Flg. Mech. Seal 1 40791 1 5050 Pump Body, 2" NPT, Packing 1 40088 1 5050 Pump Body, 2" 150# RF Flg., Packing 1 40793 1
More informationSpare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators
ENTEC WEST, INC. Spare Parts List EW-3500-C and D EW-4200-C and D Marine Diesel Generators Every generator produced by Entec West, Inc. has been recorded in a master computer file by serial number. This
More informationNOTICE TO INSTALLER: Instructions must remain with installation. SECTION: FM2369
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.063 FM2369 Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS ELECTRIC AND GAS BRAISING PANS MODELS VG30 VG40 VE30 VE40 ML-126847 ML-126848 ML-126849 ML-126850 For additional information on Vulcan-Hart Company or to locate an authorized
More informationPressure Booster System Models 350 & 351
Notice to Installer: Instructions must remain with installation. Product information presented here refl ects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationOWNER S MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS. Safety Instructions. Table of Contents. Owner s Information
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here refl ects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
More informationDI PUMP PARTS PRICE LIST
ITEM 1 2 2A PUMP 5040 Pump Body, 1-1/2" NPT Mech. Seal 1 40058 1 5040 Pump Body, 1-1/2" NPT, Packing 1 40057 1 5040 Pump Body, 1-1/2" 150# Flg., Mech. Seal 1 40787 1 5040 Pump Body, 1-1/2" 150# Flg., Packing
More informationPump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp
Pump Specifications ELV Series Submersible Sump Pump with OilTector Control ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp ELV_ P1 R1/24/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS MODEL VFB6 ELECTRIC FLASHBAKE OVEN MODELS VFB6 VFB6 ML-26877 W/POWER CORD ML-26879 W/O POWER CORD For additional information on Vulcan-Hart Company or to locate an authorized
More information507/53 507/98 CAUTION. NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationLITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE
TOTAL HEAD IN FEET TOTAL HEAD IN METERS Pump Specifications PRG - SERIES Residential Grinder Pump 60 LITERS PER MINUTE 0 20 40 60 80 100 120 140 160 180 18 50 16 14 40 12 30 10 8 20 6 10 4 2 0 0 0 10 20
More informationSUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH
Installation and Service Manual SUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH For use with product built with Regal Beloit motor. Effective 04/01/09 NOTE! To the installer: Please make sure you
More informationSECTION 5 PARTS LISTS & EXPLODED VIEWS
Model 506 (UC Ice Maker) Parts Lists & Exploded Views SECTION 5 PARTS LISTS & EXPLODED VIEWS 5-1 #3752200 - Revision B - May, 2006 Parts Lists & Exploded Views Model 506 (UC Ice Maker) 506 CABINET, LINER
More informationOVEN PARTS For Models: KEBS107DBL4, KEBS107DWH4, KEBS107DBAL4 (BLACK) (WHITE) (ALMOND)
OVEN PARTS 30" BUILT IN ELECTRIC OVEN SELF CLEAN THERMAL CONVECTION 11 97 Litho in U.S.A.(dmz) 1 Part No. OVEN PARTS 1 Trim, Side (Right Hand) 4450844 Black Model 4449747 Screw 4450845 White Model 4450846
More informationHYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual
Pump Installation and Service Manual HYDROMATIC G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this
More informationPump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump
Head (Feet) Head (Meters) Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump 70 Flow (Liters Per Minute) 0 38 76 114 151 189 227 265 303 341 379 21 FLH 60 60 FL 60 18 50 15 40 12 30
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL FARHENHEIT SK-F & SKX-F SERIES SHREDDER PUMPS Electric Submersible Pumps
INSTALLATION, OPERATION & MAINTENANCE MANUAL FARHENHEIT SK-F & SKX-F SERIES SHREDDER PUMPS Electric Submersible Pumps Three Phase 208V, 230V, 460V & 575V CAST IRON THREE PHASE SK08C-F SK15C-F SK22C-F SK37C-F
More informationXFL70 FLOW RATE (LPM) Flow Rate (GPM)
Pump Specifications XFL70 Series ¾ HP Submersible Effluent Pump For Hazardous Locations Class 1, Division 1 Groups C & D Class 1, Zone 1 and Groups IIA & IIB 50 XFL70 FLOW RATE (LPM) 0 50 100 150 200 250
More informationCENTERLINE DISCHARGE. Technical Data 5730 MV 490 FRAME PULL-UP SUBMERSIBLE,
Technical Data 5730 MV 490 FRAME PULL-UP SUBMERSIBLE, CENTERLINE DISCHARGE CABLE Power and control cable are UL Listed and CSA Approved. ELECTRICAL CONNECTION Double-seal system with strain relief, consisting
More informationMAIN ELECTRIC MOTOR 900 HP 4000 V 60 HZ MAKE: RELIANCE ELECTRIC
MAIN ELECTRIC MOTOR 9 HP 4 V 6 HZ MAKE: RELIANCE ELECTRIC E.I DUPONT DE NEMOURS & CO. COOPER RIVER PROJECT PROJ: 76P PO: # LCRCP-5W RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER B795 588 9 P 6
More informationOWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class 1, Division 1, Groups C & D Applications) Explosion Proof Motors
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here re fl ects con di tions at time of publication. Consult factory re gard ing dis crep an cies or in con
More informationHYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT
PERFORMANCE DATA Wholesale Products Page: 6650-1 RPM: 3450 Discharge: * Solids: ⅟₁₆ 8 GPM 500 3/4 HP 0 2 4 6 8 10 12 14 16 18 20 HP ¾ 1 12 GPM Voltage Pump Model HE8-51 HE8-52 HE8-72 HE8-12 25 GPM 0 0
More information41-747G. Figure 1: Type DGF Relay without case (Photo)
Figure 1: Type DGF Relay without case (Photo) 2 183A113 EDSK 205342 Figure 2: Internal Schematic of the Type DGF Relay in the FT21 Case. When a ground appears in the generator field, the dc milliammeter
More informationXLE50 FLOW RATE (LPM) Flow Rate (GPM)
Pump Specifications XLE50 Series ½ HP Submersible Sewage Pump For Hazardous Locations Class 1, Division 1 Groups C & D Class 1, Zone 1 and Groups IIA & IIB 25 XLE50 FLOW RATE (LPM) 0 100 200 300 400 500
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL FAHRENHEIT J-F & JX-F SERIES SIDE DISCHARGE Electric Submersible Pumps
INSTALLATION, OPERATION & MAINTENANCE MANUAL FAHRENHEIT J-F & JX-F SERIES SIDE DISCHARGE Electric Submersible Pumps Three Phase 208V, 230V, 460V & 575V CAST IRON THREE PHASE J08-F J15H-F J15-F J22H-F J22-F
More informationA. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.
PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the
More informationProduct Information Packet ECP40802S HP,3600,2300/4000,TEFC-SD,
Product Information Packet ECP40802S-2340 800 HP,3600,2300/4000,TEFC-SD, Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationBonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits
PhysicalSupport.D 1/21/08 2:10 PM Page 121 GB4X12TMGB GB4X20TMGB GB4X12TMGBKIT Telecommunications Main Ground Bars and Kits Manufactured of 1/4 thick electrolytic tough pitch 110 alloy copper bar. Includes
More informationMultiquip Submersible Pump Model ST-3050D
OPERATION AND PARTS MANUAL Multiquip Submersible Pump Model ST-3050D COPYRIGHT 2002, MULTIQUIP INC. Revision #1 (11/18/02) MULTIQUIP INC. 18910 WILMINGTON AVENUE CARSON, CALIFORNIA 90746 310-537-3700 800/421-1244
More informationMODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL
MODELS WG/WGX20* *Used in Hazardous Locations Class I, Division 1, Groups C & D GRINDER PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner
More informationMixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL
Mixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL Document Ref M-004 Rev 0 June 2004 Contents 1 - General Instructions GF 37 Gear Drive Portable Mixer Drawing No H-3022-1 1.1 Inspection 1.2
More informationMODELS WGL20, WGL20H and WGL20F
MODELS WGL20, WGL20H and WGL20F GRINDER PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party
More information