According to IEC According to EN60598,EN55015 VIGOROSO EMERGENCY UNIT FOR LIGHTING TECHNOLOGY. Tel: Fax:
|
|
- Beatrice Burns
- 5 years ago
- Views:
Transcription
1 VIGOROSO EMERGENCY UNIT FOR LIGHTING TECHNOLOGY Tel: Fax: Skype:pwmwm1234 According to IEC According to EN60598,EN55015
2 Product Features: i. LED emergency modules,including inverter and batteries,be installed in the lighting fixture or metal box ii. iii. iv. Suitable to LED light with external driver,it is belonged to VL series emergency kits. LED indicator,test switch are equipped,easy to know the work state,test if the lamp have proper functioning Capacity of battery control the emergency time.we use NICD battery 12v for the case to make emergency time 1/2/3 hours 12v Battery VL SERIES constant current for led light v. When mains supply is normal,the battery will charge in full. When power failure will happen, then automatically the load will be powered by the kit (through the battery). If electricity will be restored at any time, the battery will cycle to charge.the emergency modules operate from - 20 degree to 50 degree.constant current mode,deep discharge protection vi. vii. User can cut off AC or use test switch to test the work state of emergency modules User can connect on/off switch to control the lamp with emergency kits. It s maintained emergency modules, switch on/off signal will be monitored accordingly, so anyone will be able to switch off the lights without Product technical Data:(Model number:vl103c018) Input Voltage:AC 85V-277V(+-10%) Batteries: 12v Output voltage:dc 15-80V 50-60HZ Emergency currect:50mah-600mah Lighting source: Spot light downlight, panel, LED tube with external power supply Emergency time:1-10hours Size=155*30*40mm(inverter) Normal function Indicating LED Equipped Emergency Function Testing Device Equipped Battery Technical Data: Please charge batteries over 24 hours when the first time,we have over-charge Protection.The charge currect is 0.05c Battery When lighting turn dark,maybe the batteries have no power,please connect to the main power and charge batteries Capacity Emergency time Emergency power 12v 1500mAh 1/2/3 hours 15w/7w/5w 12v 3000mAh 2/3hours 20w/10w 12v 4000mAh 3hours 13w 12V 5000mAh 3hours 15w
3 Product Features: i. LED emergency modules,including inverter and batteries,be installed in the lighting fixture or metal box ii. iii. iv. Suitable to LED light with external driver,it is belonged to VL series emergency kits. LED indicator,test switch are equipped,easy to know the work state,test if the lamp have proper functioning Capacity of battery control the emergency time.we use Nicd battery 6v for the led light with smaller power to make emergency time 1/2/3 hours 6v Battery(smaller) VL SERIES constant current for led light v. When mains supply is normal,the battery will charge in full. When power failure will happen, then automatically the load will be powered by the kit (through the battery). If electricity will be restored at any time, the battery will cycle to charge.the emergency modules operate from - 20 degree to 50 degree.constant current mode,deep discharge protection vi. vii. User can cut off AC or use test switch to test the work state of emergency modules User can connect on/off switch to control the lamp with emergency kits. It s maintained emergency modules, switch on/off signal will be monitored accordingly, so anyone will be able to switch off the lights without activating the emergency mode. Product technical Data:(Model number:vl053c018 ) (For smaller power with smaller size) Input Voltage:AC 85V-277V(+-10%) Batteries: 6v Output voltage:dc 15-80V 50-60HZ Emergency currect:50mah-200mah Emergency power:2w-8w Lighting source: Spot light downlight, panel, LED tube with external power supply Emergency time:1-10hours Size=155*30*40mm(inverter) Normal function Indicating LED Equipped Emergency Function Testing Device Equipped Battery Protection Device Equipped LED Driver Not Included Start-up Charging Time 24 hours Battery Technical Data: Please charge batteries over 24 hours when the first time,we have over-charge Protection.The charge currect is 0.05c When lighting turn dark,maybe the batteries have no power,please connect to AC and charge batteries Capacity Emergency time Emergency power 6v 1500mAh 1/2/3 hours 8w/4w/2w 6v 2500mAh 1/2/3hours 12w/6w/4w 6v 4000mAh 2/3hours 9w/7w 6V 5000mAh 3hours 8.5w
4 Product Features: i. LED emergency modules,including inverter and batteries,be installed in the lighting fixture or metal box ii. iii. iv. Suitable to all the LED light from 1w to 50w,it is belonged to VH series emergency kits. LED indicator,test switch are equipped,easy to know the work state,test if the lamp have proper functioning Capacity of battery control the emergency time.we use NICD battery 12v for the case to make emergency time 1/2/3 hours VH SERIES v. When mains supply is normal,the battery will charge in full. When power failure will happen, then automatically the load will be powered by the kit (through the battery). If electricity will be restored at any time, the battery will cycle to charge.the emergency modules operate from -20 degree to 50 degree.deep discharge protection vi. User can cut off AC or use test switch to test the work state of emergency modules 12v Battery AC/DC Output vii. User can connect on/off switch to control the lamp with emergency kits. It s maintained emergency modules, switch on/off signal will be monitored accordingly, so anyone will be able to switch off the lights without activating the emergency mode. Product technical Data:(Model number:vh103c018) Input Voltage:AC 85V-277V(+-10%) Batteries: 12v Output voltage:dc/ac 220V 50-60HZ Emergency power: Full power Lighting source: Spot light downlight, panel, LED tube Emergency time:1/2/3hours Size=210*30*40mm(inverter) Normal function Indicating LED Equipped Emergency Function Testing Device Equipped Battery Protection Device Equipped LED Driver Not Included Start-up Charging Time 24 hours Battery Technical Data: Please charge batteries over 24 hours when the first time,we have over-charge Protection.The charge currect is 0.05c When lighting turn dark,maybe the batteries have no power,please connect to AC and charge batteries Capacity Emergency time Emergency power 12v 1500mAh 1/2/3 hours 15w/7w/5w 12v 3000mAh 1/2/3hours 30w/15w/10w 12v 4000mAh 1/2/3hours 40w/20w(18w)/13w 12V 5000mAh 1/2/3hours 50w/25w(23w)/15w(18w)
5 Lighting source The emergency kits are suitable to different lamp LED Bulb LED Spotlight LED Downlamp LED Ceiling lamp LED Tri-proof lamp LED Strip light LED Tube Light LED Flood Light LED Panel Light PL lamp Fluorescent lamp
6 Vigoroso Technology Accessories Battery Holder Battery connector LED indicator Outer Box1 connector lug Binding Post DC connector Power Line Outer Box2 connector lug Test Switch Earthing Lug Outer Box3
ISO9001 DC TO AC POWER INVERTER. DC 12V TO AC Instruction Manual Please read user manual before use. CAUTION
DC TO AC POWER INVERTER POWER: 100W/150W/175W/200W/250W 300W/400W/500W/600W/800W 1000W/1200W/1500W/1800W 2000W/3000W CAUTION (A) PALACE THE INVERTER IN A WELL VENTILATED ENVIRONMENT (B) DON'T EXPOSED THE
More information1set of Lighting Fixture Unit (40W) X 8 hours = more than 4 trees planted
LEDLITEK CO.,LTD. E-mail w9jung@ledlitek.com www.ledlitek.com Tel +82-70-4331-3550 Fax +82-43-263-3308 Address Buyong District Industrial Complex 246 Kumho-ri Buyong-myeon, Cheongwon-gun, Chungcheongbuk-do,
More informationINSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical
More informationThe Reflex professional adjustable iguzzini
Adjustable s with circular shape. Available in versions with rim for ceiling-mounted installation and without rim for ceiling-flush installation. Professional optics for low voltage lamps and discharge
More informationMAGNETIC TROFFER RETROFIT KIT
PROJECT NAME: PROJECT NOTES: LED SOLUTIONS, INC. www.jaykal.net 26832 Lewes Georgetown Hwy, Building 2, Unit E Harbeson, DE 19951 (P) 302-295-0015 (F) 302-295-0016 DESCRIPTION: The simple design of the
More informationLIGHTING & ELECTRICAL FOR STANDARD BOOTH
LIGHTING & ELECTRICAL FOR STANDARD BOOTH Electrical equipment for Standard Booth package (Inclusive of Power Consumption) ITEM Early Rate Stantdard On-site by 20 Jul 18 21 Jul 25 Aug to 24 Aug 18 to 11
More informationIndividually styled Beautifully built
Individually styled Beautifully built Bessacarr Motorhomes Dunswell Road, Cottingham, East Yorkshire HU16 4JX. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftleisure.co.uk website: www.bessacarrmotorhomes.co.uk
More informationSTANDARD ONDUFIL TM MULTI-TURN SPRING WASHER RANGE
per turn RD0223S320025IX 22.0 18.0 2.0 x 0.25 3.5 3 5.8 3.0 4.0 1.4 RD0223S420025IX 4 7.8 4.0 4.0 1.0 RD0223S520025IX 5 9.6 4.3 4.0 0.7 RD0223S620025IX 6 11.0 5.0 4.0 0.7 RD0223S720025IX 7 12.7 5.8 4.0
More informationSwift Motorhomes website:
Quality with Style Swift Motorhomes Dunswell Road, Cottingham, East Yorkshire HU16 4JX. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftgroup.co.uk website: www.swiftmotorhomes.co.uk A member of
More informationLIGHTING & ELECTRICAL FOR STANDARD BOOTH
LIGHTING & ELECTRICAL FOR STANDARD BOOTH Electrical equipment for Standard Booth package (Inclusive of Power Consumption) Early Rate Stantdard On-site 1 AUG 17 2 AUG 22 AUG to 21 AUG 17 to 10 SEP 17 Standard
More informationEnjoy the freedom Issued January A member of the Swift Group
Enjoy the freedom 1080780 Issued January 2008 Ace Motorhomes Dunswell Road, Cottingham, East Yorkshire HU16 4JX. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftleisure.co.uk website: www.acemotorhomes.co.uk
More informationECO Spot 2500 User Manual
ECO Spot 2500 User Manual Thank you for choosing an ECO Spot 2500 Profile Spot. The projector part is based on a modified ETC Source Four and most of the available standard Source Four equipment, such
More informationECO Spot 2500 User Manual
ECO Spot 2500 User Manual Thank you for choosing an ECO Spot 2500 Profile Spot. The projector part is based on a modified ETC Source Four and most of the available standard Source Four equipment, such
More informationLED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting
LEDAZ Solution meets clients every lighting requirement, covering a wide range of product portfolio including LED Reflector, LED Downlight, LED Tube, LED Plug-in Tube, LED Sensor Batten and LED Floodlight.
More informationBRIDGE HARDWARE (WHOLESALE SUPPLIES) Tel: Fax: PRODUCT GUIDE
BRIDGE HARDWARE (WHOLESALE SUPPLIES) Tel: 01406 351249 Fax: 01406 351658 PRODUCT GUIDE ELECTRICAL, FITTINGS, CABLE, CABLE CLIPS AND LAMPS CONTENTS PAGE 67 ELECTRICAL PAGE 1 PAGE 68 ELECTRICAL PAGE 2 PAGE
More informationLighting Price List. LED Bulbs LED Battens LED Panels LED Spot Lights
Lighting Price Li Effective 1 Oct' 2018 LED Bulbs LED Battens LED Panels LED Spot Lights LED Lamps PRO ECO PRO ECO PRO ECO DECO LED 0.5W LED Lamp Amber Eco B22d White 48 29 75 0.5W LED Lamp Amber Eco B22d
More informationInstruction/Installation Manual
Instruction/Installation Manual Retrofit:LED Tube Lamp 4ft. Fluorescent T8/T10 Replacement 1 SECTION 1 - General Information Kit components:1-led Tube, 1-Label and 1-Set of Instructions Models were only
More informationAVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips
AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug
More informationOEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose
OEM Emergency Portfolio Product Guide Emergency components for LED, fluorescent and auxiliary purpose Contents Introduction to this guide 3 LED Modules 4 PHL-EL3 PHL-EL3-80 PHL-EL3-D PHL-EL3-D80 PHL-EL3-4
More informationCHENGEE TECHNOLOGY. 5W GU5.3 Base MR16 LED Spotlight Bulb. LED Lighting CCB1 Series CCB1-05 C - 1
TECHNOLOGY LED Lighting CCB1 Series CCB1-05 5W GU5.3 Base MR16 LED Spotlight Bulb Suitable for 12V AC/DC Equal to 50W Conventional MR16 Fully compatible with halogen MR16 Long lifetime up to 25,000 hours
More information2017 Eurolite (Pty) Ltd.
2017 Eurolite (Pty) Ltd. 01 LED Bulbs 02 Emergency Lantern 02 LED Round Panel 03 LED Floodlight 04 LED Tube 04 Empty Fixtures for LED * Fluorescents * Weather Proof * Recessed d 05 LED Flat Linear Light
More informationHPP1 MK6-15A/20A R00 Owners Manual
J Wolmarans Page 1 2018/10/23 Page 1 of 7 TABLE OF CONTENTS Page 1 Introduction...2 2 Model...2 3 Safety warnings...2 4 Contents...2 5 Features...2 6 Installation...3 6.1 Mounting the unit:...3 6.2 Connecting
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More informationSIZES The size of a bulb is determined by the measurement of its diameter. This measurement is expressed in increments of an eighth of an inch.
Below you ll find some helpful information to clarify some of the different fixture types, and how we retrofit them for maximum energy savings. SIZES The size of a bulb is determined by the measurement
More informationPIB5 PIB6 PIB7. Pg
7.2 Emergency 7.2 7.3 7.3 PEM6 PEM7 PEM8 PEM2 7.4 7.4 7.5 7.5 PIB1 PIB2 PIB3 PIB4 7.5 7.6 7.6 PIB5 PIB6 PIB7 7.7 7.7 1.9 1.9 1.10 1.10 1.11 1.11 1.12 1.10 Pg7 LEGAL REQUIREMENTS The Occupational Health
More informationIllumina LED. Luminaires with anti-black out rechargeableleds, and battery charger function
110 Illumina LED Luminaires with anti-black out rechargeableleds, and battery charger function Illumina LED is a contemporary take on portable torches for domestic use, which also combine emergency lighting.
More informationTrustSight LED Emergency Lighting
TrustSight Emergency ar 20-95V 3W/6W Datasheet TrustSight LED Emergency Lighting TrustSight ar 20-95V 3W/6W The application of LED technology within the lighting sector also requires integration of reliable
More informationProduct Installation Instruction LED Tube Lamp Retrofit Kits
Regular T8 internal driver single end Product Installation Instruction LED Tube Lamp Retrofit Kits 1 General Description LED Tube Light adopts the new type LED as the light source, using the standard T8
More informationTHE ENERGY SAVING COLLECTION
For details of your nearest stockist tel: +44 (0)845 0340780 THE ENERGY SAVING COLLECTION Avery multi-function labels, number: 3421 the future of lighting technology EDITION NUMBER 02 Introduction What
More informationUnit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace
Assessment Requirements Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace Content: Basic electrical principles a. Explain the direction of current flow
More information20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2
20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2 Part #: HAL-24-16W-LED Page: 1 Buy American Compliant The Larson Electronics HAL-24-16W-LED is a low profile
More information150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord
150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord Part #: EPLC2-LED-150W-RT-JB2-25C The Larson Electronics EPLC2-LED-150W-RT-JB2-25C Explosion Proof LED Flood Light
More informationSpecification, Wiring Diagrams. Spirit of Adventure
Spirit of Adventure Sprite Caravans Dunswell Road, Cottingham, East Yorkshire, HU16 4JX. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftgroup.co.uk website: www.swiftgroup.co.uk A member of the
More informationPLUTO SPOTLIGHT - LED. Features include. Applications. Benefits
Spotlight LED SPOTLIGHT - LED PLUTO Pluto is a designed LED light for industrial and other applications where a small size & flexibility is of importance. Typical application areas: machine tools, vehicles,
More informationEmergency 830 MAESTRO 1.0
Emergency 830 MAESTRO 1.0 Emergency Escape Lighting EMergency 831 Range Index Emergency Escape Route Fled_E Fled_W Fled_P Fled_O 834 835 836 837 Escape Signals Onsight_W Onsight_SF Onsight_RF EMergy 839
More informationMALSR APPROACH LIGHTING. Medium-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS AND STEADY BURNING LIGHTS
Medium-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS AND STEADY BURNING LIGHTS Compliance with Standards FAA: Uses Designed according to FAA-E-2325 The approach lighting system with
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationTubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22
Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation
More informationBAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination
BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationElegance & Continental Technical Handbook
Swift Group Dunswell Road Cottingham East Yorkshire HU16 4JX Tel 01482 847332 Fax 01482 841042 email enquiry@swiftgroup.co.uk For more information visit www.swiftgroup.co.uk Issued July 2014 Elegance &
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationVENETIA STUDIUM ICARO 3 TIERS
220-240V VENETIA STUDIUM ICARO 3 TIERS 126CAR-2 Mounting Instructions INDEX p. 3...contents of the box p. 4...warnings p. 5...electrical connections p. 6...installing the fixture p. 11...cleaning and maintenance
More informationBathroom Lighting 105
Bathroom Lighting 105 Ocean 6097 4 light flush 6096 2 light bar 6095 single spot 106 Ocean Spot IP44 Rated Model No Max Wattage Diam (mm) Length (mm) Proj (mm) 6095 1x 12v/20w MR11 120 6096 2x 12v/20w
More informationChallenger Sport - Eccles Sport Technical Handbook
Swift Group Dunswell Road Cottingham East Yorkshire HU16 4JX Tel 01482 847332 Fax 01482 841042 email enquiry@swiftgroup.co.uk For more information visit www.swiftgroup.co.uk Issued July 2012 Challenger
More informationSprite. Specification, Wiring Diagrams & Bulb Chart
Touring Caravans Touring Caravans Sprite Specification, Wiring Diagrams & Bulb Chart Swift group Dunswell Road, Cottingham, East Yorkshire, HU16 4JS. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftgroup.co.uk
More informationUL AND CODE COMPLIANCE
BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing
More informationChallenger Sport Eccles Sport
Touring Caravans Touring Caravans Challenger Sport Eccles Sport Specification, & Bulb Chart Swift Group Dunswell Road, Cottingham, East Yorkshire, HU16 4JX. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftgroup.co.uk
More informationDECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LAMPS
DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LAMPS 173 Storm LED 8383 3 light flush 8384 4 light bar 8382 2 light bar 174
More informationDECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING
DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING LIGHTING 129 Ocean 6097 4 light flush 6097 4 light flush 6096 2
More informationSanitary Ware Expert, Your best choice!
(VI) Telephone function (optional) When the machine is turned on, the icon will flicker on the panel if there is an incoming call; meanwhile, the speaker will play the ring tone. Touch the button on the
More informationIdaho Profile System - Trimless
3 4/16 82mm DIRECT 3 9/16 90mm 3 6/16 85mm L3ID-TRI-SYS DR OP Article # Distribution Diffuser Length Voltage Linear Electrical Mounting Brackets Lighting Control Product Distribution Diffuser Length Voltage
More informationS HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming
S HINE V ENTURE L IGHTING S LED LAMPS Quality retrofit LED lighting products from a leader in the lighting industry Full range dimming Longer life and up to 90% energy savings Long product life and improved
More informationIntroducing a sustainable and energy efficient replacement for power consuming 35W and 50W Halogen Spotlights. An extensive range of LED Spotlights
LED Spotlights Introducing a sustainable and energy efficient replacement for power consuming 35W and 50W Halogen Spotlights. An extensive range of LED Spotlights (1.2W-8W) Product Features Uses 80% less
More informationThe modular structure makes it possible to build at least 5 configurations for each visual lens unit
180 SERIES Modular visual and audible indicators A simple bayonet system simplifies the mounting and maintenance, which can be performed in complete safety The wiring unit can be easily reached and extracted,
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
, INC. ECOLUX 6600 Series 6600/5 Explosion Protected Fluorescent Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationCEAG GuideLed AT. Cost-eff icient and environment-friendly exit sign luminaire
CEAG GuideLed AT Cost-eff icient and environment-friendly exit sign luminaire Overview GuideLed AT 1 4 2 5 2 CEAG GuidElEd At www.ceag.de Overview GuideLed AT 1 LED Lightguide technology Uniform brightness
More informationEmergency lighting units EM INVERTER
T5 T8 TC-DEL TC-SEL TC-TEL TC-L TC-DD EM, 230 240 V 50/60 Hz version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions (28
More informationFocus 54 Minor Surgery & Exam Lights
Focus Series Focus 54 Minor Surgery & Exam Lights Features: Fitted With: 150-watt halogen bulb provides 500-hr. average bulb life on standard setting Luminous Power: - 54,000 Lux (5000fc) / 39.4 (1m) -
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationCONTENT LED BULB LED SPOTLIGHT LED FILAMENT BULB LED PANEL LIGHT LED DOWN LIGHT LED CEILING LIGHT LED TUBE 25-26
Guangbo Group was founded in 1992, with a total assets of over 10 billion RMB and more than 8000 employees world wide.guangbo Group is a comprehensive enterprise, one of the top 500 private enterprises
More informationClass I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -
Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) - Part #: HALP-EMG-24-2L-BX Made in the USA The Larson Electronics HALP-EMG-24-2L-BX Hazardous Area Fluorescent
More information36 & 48 ISLAND AND WALL CANOPY RANGE HOODS
KAC-30 TECHNICAL EDUCATION 36 & 48 ISLAND AND WALL CANOPY RANGE HOODS JOB AID 4317332 FORWARD This Job Aid, KitchenAid 36 and 48 Island And Wall Canopy Range Hoods, (Part No. 4317332), provides the technician
More informationISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationModel Number Description Voltage Load Type Minimum Load Maximum Load. Incandescent / Halogen. General Purpose Fan
5 A 2-Button RF Switch 369787a 1 03.11.14 The 5 A 2-Button RF Switch controls the load automatically through wireless sensors and wireless remote controls which provides a system that delivers energy savings,
More informationTable of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4
Data sheet Integrated emergency converter for fluorescent lamps zone 2 Ex 100,000 h suitable for zone 2 hazardous areas For mains and battery supply Integrated battery management inear V inear V Emergency
More informationBAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination
BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert
More informationChallenger Sport - Eccles Sport Technical Handbook
Swift Group Dunswell Road Cottingham East Yorkshire HU16 4JX Tel 01482 847332 Fax 01482 841042 email enquiry@swiftgroup.co.uk For more information visit www.swiftgroup.co.uk Issued July 2013 Challenger
More informationChallenger SE - Eccles SE & Conqueror Technical Handbook
Swift Group Dunswell Road Cottingham East Yorkshire HU16 4JX Tel 01482 847332 Fax 01482 841042 email enquiry@swiftgroup.co.uk For more information visit www.swiftgroup.co.uk Issued July 2014 Challenger
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More information(COMMERCIAL) (12 / 24 / - 12V / 24V
CONTENTS Adaptors (EXTRA LOW VOLTAGE) Aluminium Profile / Extrusion Automotive Head Lights Awning Lights Cabinet Light Bars and Lift Kits Ceiling and Reading Lights Down Lighting - (DOMESTIC) Drivers /
More informationSuper Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation
Super Brain 977 AC/DC Charger with Dual Output and Discharge Function User s Manual Model Rectifier Corporation 80 Newfield Avenue Edison, NJ 08837-3817 Phone: 732-225-6360 www.modelrectifier.com Please
More informationThe 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.
1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL
More information7 Lighting Technology
7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting
More informationChapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976
1 Title Chapter 14:08 Factories and Works (Electrical) Regulations, 1976 2 Interpretation of terms 3 Fencing and enclosure 4 Notices 5 Safety precautions 6 Switch-boards 7 Portable electric tools and lights
More informationBolero / E500 Series. Specification, Wiring Diagrams & Bulb Chart
Motorhomes Motorhomes Bolero / E500 Series Specification, Wiring Diagrams & Bulb Chart swift group Dunswell Road, Cottingham, East Yorkshire, HU16 4JX. Tel: 01482 875740 Fax: 01482 840082 email: enquiry@swiftgroup.co.uk
More informationThe Hallmark of Excellence
The Hallmark of Excellence Sterling Caravans, Dunswell Road, Cottingham, East Yorkshire HU16 JX. Tel: 0182 87570 Fax: 0182 80082 email: enquiry@swiftleisure.co.uk website: www.sterlingcaravans.co.uk A
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More information2014 / Verlichting
14 / 15 Verlichting SPOTLIGHT - HALOGEN SUNNEX HT 10W HALOGEN Sunnex HT is a small and convenient universal light which is ideally suited for all types of precision work. Supplied with a 10W halogen bulb,
More informationG2 MAGNETIC RETROFIT KIT
PROJECT NAME: PROJECT NOTES: LED SOLUTIONS, INC. www.jaykal.net 26832 Lewes Georgetown Hwy, Building 2, Unit E Harbeson, DE 19951 (P) 302-295-0015 (F) 302-295-0016 DESCRIPTION: The simple design of the
More information56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof
56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications - 7000 Lumens - IP67 Waterproof Part #: GVP-48-2L-LED Page: 1 The Larson Electronics GVP-48-2L-LED is similar to our popular explosion proof
More informationReflex. Reflex. Chip on Board (C.o.B.) frame / minimal page 90/96/100. Wall Washer optic. Adjustable optic. Fixed optic. ø 242. ø 212. ø 153.
Reflex Reflex frame / minimal page 90/96/100 Fixed optic Wall Washer optic Adjustable optic ø 242 Super Comfort White reflector ø 153 Super Comfort White reflector ø 96 White reflector ø 75 White reflector
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
ECOLUX 6608 Series 6608/5 Explosion Protected Fluorescent Emergency Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More information3200 SERIES BACK LIT CONVEYOR Special Capabilities Specification Sheet
975 Cottonwood Ave., PO Box 20, Hartland, Wisconsin 53029-0020, USA www.dorner.com info@dorner.com BACK LIT CONVEYORS A light fixture is installed inside the conveyor frame and emits light through a translucent
More informationPNL LED Underwater Light
PNL-70071 LED Underwater Light IMPORTANT: This manual includes essential information on the safety measures to be implemented for installation and start-up. Therefore, the installer, as well as the user,
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationMicro Lighting Inverter
Micro Lighting Inverter IMP/IMP-M Series Modified Sine Wave RATINGS TABLE MODEL # MOUNTING DC Voltage 12V S = SERIES SP = SERIES PARALLEL Input/Output Voltage IMP-M 50 T Grid 12V S 120 V IMP-M 50 Recessed
More information18 Watt LED Fixture for Industrial Lighting - Aluminum Housing 120/277 or 12/24VDC - IP65 Waterproof
18 Watt LED Fixture for Industrial Lighting - Aluminum Housing 120/277 or 12/24VDC - IP65 Waterproof Part #: LEDBLT-18W Page: 1 The Larson Electronics LEDBLT-18W is a low profile industrial lighting solution
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationSPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E
SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500
More informationSPECIFICATION FOR VH F CONTENTS
CONTENTS 1/ SCOPE 2/ GENERAL ELECTRICAL CHARACTERISTICS 3/ GENERAL MECHANICAL CELL SPECIFICATION 4/ CAPACITY 5/ CHARGE RECOMMENDATIONS 6/ CYCLE LIFE 7/ CELL AND BATTERY MANAGEMENT 8/ SPECIFICATION APPROVALS
More informationEmergency lighting units PC COMBO
TC-DD PC CFL E COMBO, 230 240 V 50/60 Hz Compact fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For TC-DD compact fluorescent lamps For manual testing
More informationRecessed Downlights. Zas
IN Recessed Downlights 2.4 Zas Recessed small downlight with a square frame and with Cardan system. Great energy savings in general lighting applications. Guidance system that provides multiple options
More informationCombined ballast. Combined ballast XCU 16 XCR 17 XHF Batteries 20. Combined ballast.
Combined ballast Combined ballast XCU 16 XCR 17 XHF 18-19 Batteries 20 15 Combined ballast XCU The XCU combined units together with the appropriate inverter circuits For Linear and TC-L fluorescent lamps
More informationFiberSource Q150. user manual P/N
FiberSource Q150 user manual P/N 510260 1997, 1998 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing
More information09 Undershelf & Cabinet 9_Undershelf_Cabinet_29.indd /08/ :39
09 Undershelf & Cabinet 175 177 180 181 Skyblade 4W Skyblade 8W T5 Undershelf LV Undershelf 9_Undershelf_Cabinet_29.indd 173 24/08/2015 17:39 Unique edge lit LED undershelf lighting Suitable for single
More informationCATALOG RECHARGEABLE LED LANTERNS. Pages INSECT KILLERS. Pages 06-15
CATALOG 2018 Pages 01-05 RECHARGEABLE LED LANTERNS Pages 06-15 INSECT KILLERS www.fanelite.com RECHARGEABLE LED LANTERNS KN-6120LSMD EAN 3 760158 351924 RECHARGEABLE 120 LED LANTERN Battery White Ideal
More information