Product Installation Instruction LED Tube Lamp Retrofit Kits
|
|
- Maximilian Banks
- 6 years ago
- Views:
Transcription
1 Regular T8 internal driver single end Product Installation Instruction LED Tube Lamp Retrofit Kits
2 1 General Description LED Tube Light adopts the new type LED as the light source, using the standard T8 tube s end caps, makes it easy to install and replace the traditional fluorescent lamp. The models is T8 LED Tube Lamp; the rating is 100~277Vac, 50/60 Hz, 9 W for Model FY-T8-600NX, the whole length is 0.6m; 14 W for Model FY-T8-900NX and FY-T8-1200NXS, the whole length is 0.9m and 1.2m, 18W for Model FY-T8-1200NX, the whole length is 1.2m; 22W for Model FY-T8-1200NXB and FY-T8-1500NX,the whole length is 1.2m and 1.5m; 26W for Model FY-T8-1800NX, the whole length is 1.8m; 36W for Model FY-T8-2400NX, the whole length is 2.4m; The package of Model FY-T8-600NX, FY-T8-900NX, FY-T8-1200NXS, FY-T8-1200NX, FY-T8-1200NXB is consists of LED Tube Lamp (1 pcs), installation instruction (1 pcs). Label (1 set). The package of Model FY-T8-1500NX,FY-T8-1800NX,FY-T8-2400NX is consists of LED Tube Lamp (1 pcs), installation instruction (1 pcs). Label (1 set), metal brackets (2 set), mounting screws (2 set) - A non-user replaceable light source and is known as a self-ballasted LED Tube Lamp. - An electronic LED Driver was built inside the unit. - For dry and damp location. - Has been evaluated for use with ceiling fixtures. - Not for use with light dimmers. - These lamps should be installed by an electrician; - These lamps work on line voltage and require all ballasts and starters to be removed before the bulb is to be installed in the fixture;. - Use in -20~45 degrees C environmental conditions; - Do not install in a raceway or a luminaire marked for through branch wiring. - These devices are not intended for use with emergency exits. - Always connect ground lead to fixture where applicable. - These LED tube lamps are intended to retrofit maximum 4 lamps, Type IC or Non-IC Recessed, or surface-mounted fluorescent luminaire that use straight tubular maximum 4-foot lamp with or without diffuser. - The LED Tube was connected to the branch circuit by pins on one end of lamp base; the pins on the other end of lamp base is only for mechanical support. - Please connect your authorized dealer, distributor, or rethink Environmental if you have any questions not addressed in these instructions. I
3 2 WARNING IMPORTANT SAFETY INSTRUCTIONS Danger Risk Of Shock Disconnect Power Before Installation. WARNING - Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when drilling for installation of reflector kit hardware. Check for enclosed wiring and components. WARNING - Risk of fire or electric shock. LED Retrofit kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. WARNING -To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. The end retrofit luminaire has been modified and can no longer operate the originally intended lamp. WARNING - Risk of fire or electric shock. Do not use this retrofit employing shunted bi-pin lampholders kit in luminaires Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. WARNING - To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lampholders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words Instant Start or I.S. marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer. WARNING - Fig.1 it means DOUBLE INSULATION Fig. 1 II
4 Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors. THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. Has been evaluated for use with ceiling luminaires and type IC recessed luminaires where the lamps can be totally enclosed (i.e. Can be installed in luminaires with a diffuser). 3 Installation Instructions (1) CONFIGURATIONS Outside Measurement(Dimensions shown in see Fig. 2 (mm)): Model A B FY-T8-600xxx 588±1mm 602±1mm FY-T8-900xxx 894±1mm 908±1mm FY-T8-1200xxx 1198±1mm 1212±1mm FY-T8-1500xxx 1498±1mm 1512±1mm FY-T8-1800xxx 1760±1mm 1774±1mm FY-T8-2400xxx 2369±1mm 2383±1mm Fig 2 (2)LED TUBE LIGHT FIXED DIAGRAM LED tube Fixed & Install method comply with traditional fluorescent s, LED tubes in various sizes and different weight, to guarantee the safety in used, adopting fixable Clips to fixed the following special models: FY-T8-1500NX& FY-T8-1800NX& FY-T8-2400NX. Detailed Installation Guide: Making diameter holder Ф3.2mm, using diameter Ф3.0mm screw, to connected fixable Clips by screwed, two Clips used, Clips install position refer to following diagram(see Fig 3), and then installate the LED tube(see fig 4) III
5 Fig 3 Fig 4 4 Installing (1). Installation procedure; Step 1: Remove ballast and starter where applicable, and the corresponding wires including branch circuit wires and ballast wires. If existing lampholder terminals are shorted by a jumper (as in instant start circuit), then remove the jumper. Step 2: According to the Schematic wiring diagram, connect the wire of L N in AC V with either lampholder at the end of fixture, then labeled the Output Input (refer to the below picture), in order to identify the direction for installation. Followings are installation of 3 different fixtures. IV
6 A. Luminaire with starter (See fig.6) Fig. 6 B. Luminaire with electronic ballast (See fig.7): Fig.7 C. These LED tubes can retrofit maximum four lamps in one luminaire. The revised circuit diagram as shown in Fig.8. Please see Fig.6 and Fig.7 to cut wires and to connect wires as follows: V
7 Fig.8 (2).Lamping Replacement Marking Label, See fig.9. Fig.9 After modification completes and then installs the retrofit LED Tube Lamp, then affix the Lamping Replacement Marking label to painted surface and base aluminum, located this where visible during relamping either on the ballast tray or retrofit. 5 Application Replacement tube light to be used in the office building, factories, shopping malls, schools, supermarkets, hotels, underground parking lots, subways, governmental projects and so on. VI
LED 2/3/4ft T8 Tube 120V
E-T8-1200-YR LED 2/3/4ft T8 Tube 120 Our LED Tubes utilize the latest LED chips as the light source, whilst using the standard T8 end caps, which makes it easy to install and replace traditional fluorescent
More informationTECTONIC LED CORP. ISO
TECTONIC TECTONIC LED CORP. ISO 9001:2000 Products RoHs Compliance Instruction Menu Retrofit:LED Tube Lamps SECTION 1 - General Information Kit components: 1-LED Tube, 1-Label and 1-Set of Instructions
More informationInstruction/Installation Manual
Instruction/Installation Manual Retrofit:LED Tube Lamp 4ft. Fluorescent T8/T10 Replacement 1 SECTION 1 - General Information Kit components:1-led Tube, 1-Label and 1-Set of Instructions Models were only
More informationSolid State T8 tube is the smart alternative to a
Solid State T8 tube Ideal for decorative and ambient lighting in retail outlets, hotels, restaurants, government buildings, and multi-unit residences L Prize Winner Solid State T8 tube Direct Replacement
More informationInstallation Instructions: Memory-Dimmable SEP T8 Tube Lamps
Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps Installation Notes & Precautions: Memory-Dimmable SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.
More informationwww.greenelectricalsupply.com 1x4 2x2 & 2x4 Read all instructions and warnings before attempting installation. RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES
More informationInstallation Instructions: External-Driver SEP T8 LED Tube Lamp
Installation Instructions: External-Driver SEP T8 LED Tube Lamp Installation Notes & Precautions: External-Driver SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.
More informationINSTALLATION INSTRUCTIONS
LED LIGHT ENGINE APPLICATION PROGRAM INSTALLATION INSTRUCTIONS LED Light Engine Kit Model: 9 Round Engine 120V: TRIAC DIMMING TKT120025RDxx-01 TKT120025RDxx-11 TKT120021RDxx-01 TKT120021RDxx-11 TKT120025RDxx-02
More informationInstallation Guide. WARNINGS Read all instructions and warnings before attempting installation
Installation Guide WARNINGS Read all instructions and warnings before attempting installation ALWAYS MAKE ABSOLUTELY SURE THE POWER IS OFF WHEN PERFORMING THE FIXTURE MODIFICATION. DURING INSTALLATION,
More informationULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS
Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components
More informationUniversal Retrofit System Installation Instructions Revised:
Universal Retrofit System Installation Instructions Revised: 20150624 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to
More informationSTOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY
STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY WARNING Risk of fire or electrical shock. LED retrofit installations require knowledge of luminaire electrical systems. If not qualified,
More informationStrip Fixture URS Light Bar Retrofit Installation Instructions Revised:
Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency
More informationLUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS
More informationStik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS
Stik Families Qwik Stik, Street Stik, Slim Stik, Tap Out Stik Product Retrofit Guide WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property
More informationINSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02
INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02 Important safety information - read all instructions before installation. WARNING Risk of fire or electric shock. Luminaire wiring and
More informationT8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr
T8 Tube Light Ideal for decorative and ambient lighting in retail outlets, hotels, warehouses, government buildings, and multi- unit residences T8 Tube Light UL LISTED & cul LISTED & DLC LISTED Germany
More informationINSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit
10W DirectAC Engine TJT120010ACxyyB 15W DirectAC Engine TJT120015ACxyyB INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit TJT120010ACxyyB TJT120015ACxyyB TJT120023ACxyyB TJT120010ASxyyC TJT120010ACxyyC
More informationLUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS consist
More informationLED Recessed Troffer Retrofit Kit
Model # TRK series LED Recessed Troffer Retrofit Kit Installation Instructions PACKAGE CONTENTS A B E Part Item Name Qty. A Retrofit assembly 1 B Bracket 2 C Sheet metal screw 4 D Wire nuts 5 E Gap channel
More informationOPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS
OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS 99-24283-I001 Table of Contents 1. 24V LED Approved Drivers 5 1.1. 24V LED Driver (60-19910-0002).. 5 2. Optimax Radiant 24V LED Lighting. 6 2.1. OP30 6 2.2.
More informationInstallation Instructions BLTR and 2BLTR Relight Assembly
UT4540 Rev. B Installation Instructions BLTR and 2BLTR Relight Assembly This Relight assembly was engineered to upgrade most recessed fixtures mounted in T-grid ceiling installations, including most parabolic
More informationLED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling
More informationOptimax Pro Retrofit Instructions
Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part
More informationMAXLITE RKT LED Retrofit Kit
MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent
More informationAsymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.
support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Installation Instructions 2RTLEDR/2RTLEDRT Relight Assembly READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. IMPORTANT SAFETY INSTRUCTIONS WARNING:
More informationLED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards
GE ighting ED T8 BP Tubular lamps DATA SHEET Product information The GE ED T8 range offers safe, reliable and affordable energy saving alternatives to standard Fluorescent T8 lamps. Available in 60cm,
More informationS HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming
S HINE V ENTURE L IGHTING S LED LAMPS Quality retrofit LED lighting products from a leader in the lighting industry Full range dimming Longer life and up to 90% energy savings Long product life and improved
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION
UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL
More informationAssembly Instructions Retrofitting
Assembly Instructions Retrofitting These instructions are for replacing existing lighting fixtures or systems with our new, higher efficiency TLS, drivers and controls. www.tls-lumisign.com 514-858-6556
More informationLED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)
LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY
More informationLED. High-performance streetlight. -afortable and reliable
LED High-performance streetlight -afortable and reliable DESIGNED FOR FUNCTIONAL LIGHTING OF OUTDOOR ROADS WHERE ENERGY SAVING, LOW MAINTENANCE AND PRECISE LIGHT CONTROL CONSIDERATIONS ARE IMPORTANT FACTORS.
More informationLumination TM LED Luminaire LUR Series
Installation Guide Lumination TM LED Luminaire LUR Series BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Turn power off before inspection,
More informationECO EXT (DIMMABLE)
Not all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. ECO EXT (DIMMABLE) www.trulygreensolutions.com
More informationIMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Installation Instructions RT8RT/RT5RT Relight Assembly READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. IMPORTANT SAFETY INSTRUCTIONS WARNING: FAILURE
More informationINSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F
SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.
More informationLED microwave sensor T8 tube light
LED microwave sensor T8 tube light Product Feature Microwave sensor LED T8 offers a driver and radar sensor intergrated technology. The new technology helps the LED tube save more energy. LED tube will
More informationTRUET5 EXT (DIMMABLE)
t all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. TRUET5 EXT (DIMMABLE) www.trulygreensolutions.com
More informationINSTALLATION INSTRUCTIONS
INDIGO-CLEAN TECHNOLOGY RETROFIT KIT INSTALLATION INSTRUCTIONS 1 IMPORTANT SAFETY INFORMATION Risk of shock. Disconnect power before installation. DANGER- RISQUE DE CHOC- COUPER L ALIMENTATION AVANT L
More informationINSTALLATION GUIDE Works in double and single ended wiring.
ISTAATIO GUIDE Works in double and single ended wiring. -1- Safety Precautions For your and others safety, please read the precaution carefully before installation: (1). Product should be installed by
More informationAnthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A
Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A 99-16999-0000 Table of Contents 1. Removing Fluorescent Lighting... 4 1.1. Detach the lens assembly... 4 1.2. Remove
More informationKT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all repalcment lamp types marked on the installed luminaire
More informationSubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M
SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Type A design complies with AS/NZS 60598.2.1:2014/
More information3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all replacement lamp types marked on the installed luminaire
More informationTechnical Application Guide for UP-SHINE LED Downlight
Technical Application Guide for UP-SHINE LED Downlight UP-DL36-42W(1 inch) Introduction Up-shine DL36 downlight retrofit kits are designed with CREE COB LED chip, utilization of high efficient reflector
More informationUL AND CODE COMPLIANCE
BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Champ Fluorescent Luminaires DMVFB Auxiliary Series - 52, 64, & 84 Watt Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1713 IMPORTANT SAFEGUARDS READ AND FOLLOW
More informationLED Fluorescent Replacement
LED Fluorescent Replacement Find the perfect LED alternative for fluorescent lamps while eliminating mercury content from your lighting system. Increased energy efficiency makes these lamps the ideal replacement
More informationPDX and PX Retrofit Series
UNIQUE LIGHTING SOLUTIONS PDX and PX Retrofit Series PDX1-1-12-XX PX1-1-12-X-X-XX-65 RETROFIT INSTALLATION GUIDE PDX and PX Series Retrofit WARNING -Retrofit installation must only be performed by a licensed
More informationGeneral Installation Instructions LED
General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings
More informationINSTALLATION INSTRUCTIONS STEP-DOWN TRANSFORMER HOUSING KIT
Rev NSTLLTON NSTRUCTONS STP-DOWN TRNSFORMR HOUSN KT Step-Down Transformer Housing Kit Compatibility: Step-Down Transformer Housing Kit Step-Down Transformer High-ay Conversion Kit HHLPQ32840 HHLSSD1125V
More informationINSTALLATION INSTRUCTION W Track Recessed 120V Flangeless
W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL SAFETY INSTRUCTION Read all of these instructions before installing the track system. Turn off power at main switch before installing or modifying
More informationBeam lights & conversion kits
.0 Overview... 81.1 Planete 2000... 82.2 Beamlite... 83.3 Gemini Junior... 84.4 EL40... 8. Conversion Kit... 86 Emergency lighting design handbook revision 4 dh_el_rev.4_eng July 2014 79 80 Emergency lighting
More informationFOR INDOOR/SEASONAL USE ONLY
9' Warm White /Multi LED Color Changing One Plug Tree V66362-60 INSTRUCTION MANUAL Thank you for purchasing a SYLVANIA Pre-lighted Tree. This tree assembles in minutes and is decorated with energy saving
More informationLED SMD CANOPY FLAT FIXTURE
ASD LED Canopy Lights are designed to withstand the elements while producing a lot of light. Our low profile canopy has an acrylic lens which is UV resistant and vandal-resistant. This is an ideal replacement
More informationLUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed
Installation Guide LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Description The LUNERA VERTICAL E26 LED FLOODLIGHT is a line driven
More information(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000
Applicable Cooler Door Models: WATTS (NOMINAL) MODEL LIFE (L 70 ) DIMENSIONS (L x W x H) Nom CCT 9 36RDLxx 3ft x 1in x ¾ H 12 48RDLxx 4ft x 1in x ¾ H 15 60RDLxx 5ft x 1in x ¾ H 18 72RDLxx 6ft x 1in x ¾
More informationLightWave Lighting Technology
LightWave Lighting Technology About the company Since the inception of the company in 1998, LightWave has utilizes its expertize in lighting technology to make products that are energy efficient, cleaner
More informationSURE-LITES FBP140XLP Instruction Manual
SURELITES Instruction Manual IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION:
More informationESLED4, ESLED5 Instructions
ESLED4, ESLED5 Instructions ESLED4-1.2M (20W) ESLED5-1.5M (24W) Dimensions ( mm ): Model Cap Size (mm) A B C D Max Max Max Max ESLED4-1.2M G13 26 1200 1199.4 1206.5 1213.6 26 ESLED5-1.5M G13 26 1500 1500
More informationINSTRUCTION MANUAL SINKER. By HAY
INSTRUCTION MANUAL SINKER By HAY INTRODUCTION An elemental looking light available as either a small or large pendant. The fabric cord comes with a magnetic moulded ceiling cap in a textured finish. The
More informationIdaho Profile System - Trimless
3 4/16 82mm DIRECT 3 9/16 90mm 3 6/16 85mm L3ID-TRI-SYS DR OP Article # Distribution Diffuser Length Voltage Linear Electrical Mounting Brackets Lighting Control Product Distribution Diffuser Length Voltage
More informationAssembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM
GENERAL REMARKS ON SAFETY: Read all of these instructions before installing fixtures. Keep all of the instructions for future reference. Turn off power before installing fixture. Installation is to be
More informationWHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:
SURE-LITES Installation Instructions For FBP-1-40X IMPTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: 1. READ AND FOLLOW ALL
More informationLED Indoor Lighting Product Guide
LED Indoor Lighting Product Guide 120 Rowell Road Hampshire, IL 60140 847-302-8998 Phone 847-683-8002 www.ledrite.com LT Model T8 Series T8 LED TYPE C EXTERNAL DRIVER 2FT X 2 RETROFIT KIT This T8 LED 2FT
More informationBALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST
BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST APPLICATION The BALT5-800 low-profile fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures
More informationWARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
2 Please read the safety and installation instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Photo-catalytic Air Purifier. WARNING: FAILURE
More informationIconic LED, LLC. "All in one T8" Compatible with or without ballast. WorkswithSingleEndandDoubleEnd
Iconic ED, ISTED "All in one T8" ompatible with or without ballast. WorkswithSingleEndandDoubleEnd PRODUT SPEIFIATIO DESRIPTIO: ED T8 TUBE SERIES PRODUT MODE: WHD-T8-0WB, WHD-T8-8WB, WHD-T8-WB BASI PARAMETERS
More informationBAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:
1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be
More informationIvalo Finiré 3 LED Recessed Lighting Installation Instructions
IMPORTANT INFORMATION Please Read Before Installing 367-2578e 1 09.20.16 Important Notes IC fixtures must be used for installations containing insulating materials and must be mounted away from heat producing
More informationLM79 LM80 L70:5+ YEARS
1.30.18 Want to make your shop Highly Efficient, too? Reduce install mistakes and improve efficiency by transforming your shop with our 24volt System. With our 24volt PhxNRG MODULES, our 24volt PhxNRG
More informationPRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)
Please indicate which products and services your company can supply by checking the appropriate box(es). Check only the first box if your company can supply all of the products and services shown for this
More information6. Easy for maintenance & drivers replacement. Detachable in 1 minute. Part No. Power Luminous Input Voltage PF CRI Diffuser Certificate
Features 1.70% energy saving compared with fluorescent lamps. 2. Super brightness SMD2835 LEDs with LM80 report. 3.Soft and uniform light.no glare & no flickering Wide beam angle@ 160 4.Premium & optical
More informationHBC-20 - LED HIGH BAY
To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA.) in Canada. Risk of fire or
More informationBAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination
BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert
More informationSpecification sheet of T8 LED Tube
Specification sheet of T8 LED Tube Brief Introduction Special designed lockable 90-180 degree rotating end caps Lighting efficiency up to 100-110lm/W, Saves up to 70% Energy, Good a l t e rn at i ve to
More informationStandards Update Notice (SUN) Issued: June 6, 2017
Standard Information Standard Number: UL 153 Standard Name: Portable Electric Luminaires Standard Edition and Issue Date: 13 th Edition Dated March 3, 2014 Date of Revision: January 20, 2017 Date of Previous
More informationINSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical
More informationLinear Tubes Compacts
Linear Tubes Compacts How to order lamps from RAB Our model numbers are easy to build and understand. Simply choose from the descriptions below each section of a matrix as seen below, and be sure to include
More informationLED Flat Panel Luminaires
LED Flat Panel Luminaires Great Features/Benefits TCP s LED Flat Panel Luminaires feature a slim, low-profile design with full panel diffusion and superior uniformity. These DLC Premium listed flat panels
More informationInstallation Instructions: Eco-Fit T8 LED Tube Lamp
Installation Instructions: Eco-Fit T8 LED Tube Lamp Key Features Ballast-ready Compatible with existing fluorescent ballasts No mercury or UV Long 50,000-hour life UL, cul, RoHS Rugged, solid-state design
More informationTechnical Application Guide for UP-SHINE LED Tube Light
Technical Application Guide for UP-SHINE LED Tube Light UP-T836W24-R Introduction Up-shine AL+PC LED Tube light adopts LM- 8 2835 SMD LED with high brightness and slight light decay..8mm thickness AL663
More informationDreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet
Product datasheet Dreamer Series LED bulb A60 Product benefits Eye cared lamp design, no UV and IR, reducing photobiology harmful effects to a lower, meet and passed IEC/EN 62471 certification Easeful
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
ECOLUX 6608 Series 6608/5 Explosion Protected Fluorescent Emergency Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationMEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:
MEDIA LED Pendant Standard Mount WARNING: Disconnect main power at the source prior to installation! Thread gripper base onto 1 /4 20 stud, or with #8 screw. Depress gripper nozzle to insert aircraft cable.
More informationMotion and Light Sensor Kit LHBAS51
Motion and Light Sensor Kit LHBAS51 Installation Instructions For Linear Low and High Bay Fixtures PLEASE READ THESE INSTRUCTIONS BEFORE SAFETY INSTRUCTIONS AND WARNINGS WARNING: READ CAREFULLY BEFORE
More informationAOD T5 LED Batten Luminaire is an environment-friendly semiconductor light which possesses a number of
AOD T5 LED Batten Luminaire is an environment-friendly semiconductor light which possesses a number of advantages over the conventional ones such as no flashing, comfortable light and high color-rendering
More information50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW
50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW Part #: WAL-SL-5-LED-12.3 Page: 1 The Larson Electronics WAL-SL-5-LED-12.3 Work Area Lighting LED String Light
More informationIncentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )
Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * ) Energy Trust offers cash incentives to help you implement approved energy efficient lighting measures. If
More information16in. WAREHOUSE BARN LIGHT
16in. WAREHOUSE BARN LIGHT OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationVision Profile System - Surface
4 1/8 105mm DIRECT 1 15/16 49mm L3VI-SUR-SYS DR OP X Article # Mounting Distribution Diffuser Length Angle Voltage Linear Spot x Qty Electrical Finishes Accessories Type Couplers / Lighting Control Product
More informationLED Tube Lights. Product Features. Applications
LED Tube Lights V-TAC s LED Tube Series fits perfectly into existing linear fixtures, providing better light quality and energy efficiency compared to linear fluorescent systems. Product Features Cost
More information150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B
150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B Part #: HBLP-REMG-1MLED-B-PND Page: 1 Made in Texas The Larson Electronics HBLP-REMG-1MLED-B-PND LED
More informationQuick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases
Quick Installation Guide Affinium LED Modules LFM300 for Refrigerated Display Cases Important Please take the time to read this installation guide before you install the Affinium LED modules and LED power
More information16 Inch Hanging Pendant Barn Light
16 Inch Hanging Pendant Barn Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationConcealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions
Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should always be followed: Read and
More informationLED Security Wallpack Installation Instruction
Featuring a slim modern design with an aluminum housing and a polycarbonate lens that is resistant to fading and cracking, this wall pack illuminates driveways, patios, loading areas, and warehouses. ASD
More information