1 Water Irrigation Products A Complete Product Range for Irrigation Applications w w w. i t r o n. c o m Water resource is more and more sollicited by increased withdrawals of many origins, especially for irrigation purpose. It is now more and more vital to better manage this resource in order to preserve it for the future. Better management means accurate metering of withdrawals in agriculture and how they are shared in order to increase their efficiency. Itron offer to the irrigation scheme managers consists in a full range of metering instruments and regulation devices, all adapted for raw irrigation water types. This range covers needs for equipment of under pressure collective irrigation networks (hydrants) as well as equipments for individual pumpings (meters and accessories). The range comprises: Irrigation Hydrants Hydrants (type A, A, B, B) are giving access to an irrigation network under pressure. They allow to share the resource by individual consumptions metering and by controlling key contractual parameters such as pressure and flow-rate. An irrigation hydrant is a compact and modular device including the following functionalities: connection to the collective network, valve closing apparatus, fitting of to outlets allowing individual metering, pressure regulation and flow-rate limitation. Pressure Regulating Devices Pressure regulators are spring cartridge type, they reduce and control network pressure in order to protect end user installations from downstream pressure variations. Flow Limiters Flow limiters are rubber ring deforming type. They limit water withdrawals to a pre-set contractual flow-rate in order to equilibrate the network, whatever the upstream/downstream pressure variations. Meters Irrimag is a proportional mechanical meter ideally suited for abrasive meters met in irrigation applications. Irrimag is pre-equipped for communication. Various modules can be fitted to it in order to remote read the index by Radio Frequency, give access to pulses allowing flow-rate calculation for display or integration in remote control chains. For raw water applications involving low flow-rates (gardening, micro-irrigation, ), we complement our offer with turbine type meters (multi-jets) or propeller type meters (Woltmann).

2 Water Table of contents > Irrigation Hydrants... 3 > Hydrants type A and B - Description... - Head loss A hydrant dimensions... - B hydrant dimensions... 3 > Hydrant type A - Description... - Head loss... - Dimensions... 8 > Hydrant type B - Description Head loss... - Dimensions... 3 > References - Hydrant A... - Hydrant B A outlet DN B outlet DN Hydrant B... 8

3 Irrigation Hydrants Itron hydrants allow an efficient sharing of the water resource in pressurized collective irrigation network. > Valve closing system Each hydrant allows: > Connection of individual user to the collective network, > Simultaneous water consumption by many users thanks to the various outlets, > A set of regulation functions in order to share the resource among the simultaneous users. An hydrant is made of a body, comprising a valve closing apparatus, and provisions for outlet connections. Outlets are featuring metering, pressure regulation, flow limitation, quick coupling functionalities. Detailed Functionalities > Hydrant meter Nominal Diameter : 5 and 00 mm Max. flow: 0 to 80 m 3 /h - Connection In certain areas, it might be needed to bury the collective network deeper to prevent frost damages. Itron hydrants are offered in two height variants through additionnal sleeve length in order to match the depth of installation. - Valve Closure Device The valve closing system opens backflow, network pressure is then naturally closing the valve in absence of command. This allows maintenance on the head of the hydrant without closing and purging the whole network. Maintenance on the field is significantly eased (). The valve closing system is designed in such a way as to avoid water hammers. It is fully made of brass to ensure corrosion-free durable tightness. The large handwheel and specific design of the valve base are easing manual operation. () All types excluding A model. > Pressure Regulator device for outlet Nominal Diameter : 5 mm Valve setpoint : 3 to bar 3 - Metering Proportionnal technology metering is particularly well adapted to abrasive irrigation water. Meter is pre-equipped as standard with Cyble technology. Cyble modules such as Cyble RF or Cyble pulser allow to remote read the index through Radio Frequency or to get access to flow-rate processing through pulse output. - Pressure Regulator Pressure regulator is spring cartridge type. It reduces network pressure for the end user and protects it from downstream pressure variations. 5 - Flow-rate Limiter Flow limiter is rubber ring deforming type. It prevents water supplies above the contractual flow-rates in order to equilibrate the overall network and whatever the pressure variations in the collective network. > Flow Limiter for outlet Nominal Diameter : 5 mm Setting :.5 to l/s 3

4 Water > Hydrant type A Hydrant range characteristics are summarized in the table below. Hydrant type A and B Hydrant A and B are able to receive many outlets in DN5 or DN00 according type. They are then adapted for irrigation of multiple areas from the same point. They are made of a modular body with various base connections, optionnal anti-frost height. The body receives one to four compact outlets featuring metering, pressure regulation, flow limitation functionalities. The valve closure device is common to both types. > Hydrant type B Type Base connection Number and type of outlets PFA SC A DN5, 80, 00 or 50 to x DN5 B DN00 or 50 to x DN00 or to x DN5 + x DN00 0 bar 0 or 0 m 3 /h per outlet DN5 depending on the outlet model 0 bar 80m 3 /h per outlet DN00 Hydrant type A Hydrant A is a single outlet DN5 type for single area. It is made of a single piece body allowing to connect one outlet DN5. Type Base connection Number and type of outlets PFA SC A DN0/5 ((oblong holes) x DN5 bar 0 m 3 /h > Hydrant type A Hydrant type B Hydrant type B allows to reach high to very high flow-rates for large areas. It is made of a modular body with various base connections, optionnal anti-frost height. The outlet is composed by the assembly of an Irrimag meter, a pressure regulator and a flow limiter that can operate separately. Type Base connection Number and type of outlets PFA SC B DN00 or x DN00 or 0 bars 0 m 3 /h DN50 x DN m 3 /h > Low-Flow outlet > Hydrant type B

5 Irrimag () > Irrimag The Irrimag is a measuring element with > free flow in the main body > no gearing in the metered water > by-pass meter protected by deflector > low headloss The turbine type meter is connected in by-pass to the main body. The flow in the body generates a pressure difference derivating part of water into the by-pass meter that operates by proportional measurement. Irrimag is standard pre-equipped with Cyble technology. Various communication modules can be fitted to the meter without dismounting any part and breaking any seal. The communication modules allow remote read of the volume index in difficult-to-access locations, flow-rate calculation, or integration in remote control chains. DN mm Max. flow rate (permanent) m 3 /h Accuracy ± 5% m 3 /h Starting flow m 3 /h Δp at permanent flow rate bar Connection Flange PN0/ Flanges PN0 or PN Pressure Regulator In the presence of flow, a spring cartrdrige opens and closes on a metallic seat to compensate upstream pressure variations. At zero flow, the cartridge shuts tight on its metallic seat and regulates the downstream pressure at the set value increased by maximum 30%. DN mm Adjustment values (PAC) - bar 3 to - to various pre-settings in the indicated range () adjustable on site 3 to to 0 Regulation range bar 0/,xPAC + 0,5 (for flow-rates above Min operating fow-rate) 0/,3xPAC (in absence of flow for Pupstream-PAC<7 bar) Min. operating flow-rate (Rmin) l/s.5 5 Min. operating pressure 5 bar Connection Flange PN Flow-rate Limiters Flow limiter is rubber ring deforming type. The rubber ring deforms under the action of downstream pressure and reduces the bore hole section. The head loss generated reduces the flow-rate to the adjustment pre-set value. > Flow Limiters DN mm () Adjustment values (NL) - various pre-settings in the indicated range () l/s (m 3 /h) 0. () to. (8).8 (0) 3.9 () (7) to (75) Limitation range 0 to,5xnl 0 to,xtr Max. differential pressure bar Class (5 bar) Class ( bar) Connection Inlet/Outlet female thread G B Inlet/Outlet female thread G /B In-between flange assembly (specific seals supplied) () refer to specific brochures for more details. () DN80 and DN50 on demand, contact us. 5

6 Water Hydrant Type A and B > Modular design of hydrant bodies > Backflow valve closing operation > Large choice of outlets designed for various applications > Hydrant A The Itron range of hydrants has a modular design to offer a large choice of inlet/outlet combinaisons with a wide range of operating flow-rates, while limiting the number of spare parts for maintenance to the minimum. Modular design The A and B hydrant types share common base and valve closing system. The hydrant base is available with various diameters for easy connection to the collective network. The body could optionally include an antifrost sleeve length for connection to deep buried networks, it is prepared for automatic purge valve fitting (supplied as an option). The choice between A or B types will depends on the number of end-users connected to the hydrant as well as on the maximum flow-rate required for each of them. > the A type has outlets 5mm allowing connection of to end-users with individual flow-rates up to 0 m 3 /h > the B type has outlets 00mm allowing connection of to end-user with individual flow-rates from 0 to 80 m3/h. Each 00mm outlet can be reduced or divided in two outlets with individual flow-rates up to 0 m 3 /h. The large handwheel and specific design of the valve base are easing manual operation. The common valve system used for A and B hydrants reduce the number of spare parts used for maintenance. Hydrant Outlets The outlets are compact and modular assemblies of devices that can be mounted on hydrant heads to compose complete hydrant product. They include on request the following functionalities: metering, flow limitation, pressure regulation, and quick coupling for connection to end user network. > the A «low flow-rate» outlet 5mm is specifically designed to improve metering accuracy in applications with flow-rate up to 0 m 3 /h. > the A outlet 5mm is designed for most standard irrigation applications with flow-rate from 0 to 0 m 3 /h > the B outlet 00mm is designed for applications requiring higher flow-rates up to 80 m 3 /h > Hydrant B Valve Closure Device The valve closing system opens backflow, network pressure is then naturally closing the valve in absence of command. This allows maintenance on the head of the hydrant without closing and purging the whole network. Maintenance on the field is significantly eased. The valve closing system is designed in such a way as to avoid water hammers. It is fully made of brass to ensure corrosionfree durable tightness.

7 Technical Characteristics Hydrant Type A B Number and type of outlets to x A outlets to x B outlets x B outlet + x A outlet x B outlet + x A outlets Connection to irrigation network DN5,DN80,DN00 or DN50 - PN (PN5 on demand) With or without anti-frost sleeve (ATG) Max admissible operating pressure (PFA) 0 bar Test pressure (Pt) 3 bar Weight (only hydrant body) Pressure release valve for outlet 5 to 50 kg ATG version : + 5 kg 3 to 8 kg ATG version : + 5 kg optionnal Dimensions > Hydrant A with anti-frost sleeve 55 without anti-frost sleeve Outlet Type* A low flowrate A B Overload flowrate per outlet (SC) 0 m 3 /h 0 m 3 /h 80 m 3 /h DNP 5mm 00mm Outlet connection A flanges DN5 or / coupling «Guillemin» type A flanges DN00 or / coupling «Guillemin» type Max admissible operating pressure (PFA) 0 bar 0 bar Test pressure (Pt) 3 bar 3 bar Weight (complete version) kg 38 kg * refer to specific brochure for more details. > Hydrant B Anti-frost sleeve Conditions of Installation 0 > Tighten hydrant body after assembly on the network under pressure (concrete tubing with gravels, supporting,...). > In case of purge valve use, ensure that water flowing is possible. > Allways purge the network before assembly of the outlets, re-use of body outlet obturator bolts and nuts is possible. > Meter, Flow limiter, Pressure regulator are sealed on hydrant outlet. All characteristics are indelebly printed on each of the items. 950 with anti-frost sleeve 30 without anti-frost sleeve with anti-frost sleeve 55 without anti-frost sleeve Anti-frost sleeve > Backflow valve closing operation 7

8 Water A, B Hydrants Head Loss Global head loss of an hydrant Exemple: B hydrant equipped with outlets : > Outlet n DNP 00 flow limiter NL= 5 l/s > Outlet n DNP 5 flow limiter NL= l/s Head loss calculation for outlet n Individual head loss values: > Flow limiter at 5 l/s =,9 > Pressure regulator at 5 l/s =, > Outlet body at 5 l/s = > Hydrant body at 9 l/s = 0,5 > Total head loss (Δh) 9,5 decibar > Flow limiter DNP 5 mm m 3 /h l/s > Flow limiter DNP 00 mm m 3 /h l/s 8

9 > Pressure Regulator DNP 5 mm (Full opening) m 3 /h l/s > Pressure Regulator DNP 00 mm (full opening) 3,5,5 0,8 0, 0, 0, 0, m 3 /h l/s > Outlet DNP 5 mm equipped with meter m 3 /h l/s 9

10 Water > Outlet DNP 00 mm equipped with meter 3,5,5 0,8 0, 0, 0, 0, m 3 /h l/s > B hydrant body (full opening) 3,5,5 0,8 0, 0, 0, 0, BASE DN 00 OR 50 mm m 3 /h l/s > A hydrant body (full opening) BASE DN 80 OR 00 mm m 3 /h l/s 0

11 > Pressure variation at the hydrant outlet The sketch below is showing the pressure variation at the end user connection versus flow-rate, considering various outlet options: with or without flow limiter. Regulated downstream pressure (PAR), PAC + 0,5 P AC R' R S' S m 3 /h, NL T, NL l/s R'S' RST NL P AC : Without flow limiter : With flow limiter : nominal flow-rate of the flow-rate limiter : setpoint downstream pressure

12 Water Hydrant type A dimensions with anti-frost sleeve 55 without anti-frost sleeve 30 Anti-frost sleeve

13 Hydrant type B dimensions with anti-frost sleeve 30 without anti-frost sleeve with anti-frost sleeve 55 without anti-frost sleeve 0 Anti-frost sleeve 3

14 Water Hydrant type A Irrigation hydrant with one outlet DN5 > Connects the end user to the irrigation water network > Includes flow limitation and pressure regulation functionality > Includes metering function, adapted to abrasive irrigation water and standard pre-equipped for remote reading Type A is composed of a single piece body with: > a flanged end for connection to the irrigation water network, > a valve closing system and command, > a head connection for one outlet DN5. The body is prepared for automatic purge valve fitting (supplied as an option). The outlet DN5 will include on request the following functionalities: metering, flow limitation, pressure regulation, quick coupling for connection to end user network. Hydrant Outlet DN5 Proportionnal technology metering is particularly well adapted to abrasive irrigation water. Conditions of Installation > Tighten hydrant body after assembly on the network under pressure (concrete tubing with gravels, supporting,.). > In case of purge valve use, ensure that water flowing is possible. > Allways purge the network before assembly of the outlets, re-use of body outlet obturator bolts and nuts is possible. > Meter, Flow limiter, Pressure regulator are sealed on hydrant outlet. All characteristics are indelebly printed on each of the items. The meter is standard pre-equipped with Cyble technology. Cyble modules such as radio or pulse modules allow to remote read the index through Radio Frequency or to get access to flow-rate processing through pulse output. Pressure regulator is spring cartridge type. It reduces network pressure to the end user and protects him against downstream pressure variations. The device is closing in absence of flow, limiting downstream pressure to the adjustment value, hence protecting the end user installation. Flow limiter is rubber ring deforming type. It prevents water supplies above the contractual flow-rates in order to equilibrate the overall network and whatever the pressure variations in the network. The outlet end might be equipped by a quick Guillemin coupling type or by a flange PN for connection to the end user network.

15 Technical Characteristics > Dimensions Hydrant Type Number of outlets Connection to irrigation network Max admissible operating pressure (PFA) Test pressure (Pt) Weight A x DN5 A Flange DN0/5 (oblongs holes) bar 5 bar kg Outlet Type Size/DNP End connection Max admissible operating pressure (PFA) Test pressure (Pt) Weight (full version) A low flowrate 5 mm A Flanged DN5 or / coupling «Guillemin» type 0 bar 3 bar kg Meter Overload flow-rate (SC) 0 m 3 /h Maximum admissible error +/- 5% from 0,7 to 0 m 3 /h Starting flow 0,5 m 3 /h Index capacity m 3 Pressure Regulating Device Version Setpoint downstream pressure (PAC) Regulation range Minimum operating flowrate (Rmin) Minimum operating pressure Stabilizer: closing in the absence of flow 3 to bar adjustable on site (pre-set values: 3-3,5--5- bar) to bar adjustable on site (pre-set values: -7, bar) - 0 to,xpac+0,5 (for flow-rate above l/s) - 0 to,3xpac (in absence of flow for Pdownstream-PAC < 7bar) L/s 5 bar Flow Limiter Adjustment values (NL) L/s (m 3 /h),38 (5) / (7) / 3(0) Limitation range 0 to,xnl Max differential pressure Class ( bar) Accessories Hydrant and Outlet uick coupling key tool Pressure release valve for outlet Automatic purge valve for hydrant optional standard optional 5

16 Water A Hydrant Head Loss Global head loss of a A hydrant: Example: A hydrant equipped with outlet DNP5 with flow limiter NL= l/s Head loss calculation: Individual headloss values: Flow limiter l/s = Pressure Regulator at l/s =, Outlet body at l/s =, Hydrant body at l/s = 0,3 Total head loss (Δh),9 decibar > Flow Limiter DN m 3 /h l/s > Pressure Regulator DN5 (full opening) m 3 /h l/s

17 > Outlet DN5 equipped with meter m 3 /h l/s > A hydrant body (full opening) m 3 /h > Pressure variation at the hydrant outlet The sketch below is showing the pressure variation at the end user connection versus flow-rate, considering various outlet options: with or without flow limiter, Regulated downstream pressure (PAR), PAC + 0,5 P AC R' R S' S m 3 /h, NL T, NL l/s R S : Without flow limiter RST : With flow limiter NL : Nominal flow-rate of the flow-rate limiter P AC : setpoint downstream pressure 7

18 Water Hydrant type A dimensions

19 Hydrant type B Modular irrigation hydrant with one large outlet Type B is composed of: > A body with a flanged end for connection to the irrigation water network, the base including the valve closing system, > A head supporting and guiding the valve command system, fitted with the following elements in DN00 or DN50: meter Irrimag, pressure regulator or stabilizer, flow limiter, quick coupling. The body could optionnally include an anti-frost sleeve length for connection to deep buried networks, it is prepared for automatic purge valve fitting (supplied as an option). Pressure Stabilizer (refer to specific brochure) Pressure regulating device is spring cartridge type. It reduces network pressure to the end user and protects it from downstream pressure variations. Flow Limiter (refer to specific brochure) Flow limiter is rubber ring deforming type. It prevents water supplies above the contractual flow-rates in order to equilibrate the overall network and whatever the pressure variations in the network. > Connects the end user to the irrigation water network > Includes flow limitation and pressure regulation functionnality > Includes metering function, adapted to abrasive irrigation water and standard pre-equipped for remote reading Valve Apparatus The valve closing system opens backflow, network pressure is then naturally closing the valve in absence of command. This allows maintenance on the head of the hydrant without closing and purging the whole network. Maintenance on the field is significantly eased. The valve closing system is designed in such a way as to avoid water hammers. It is fully made of brass to ensure corrosionfree durable tightness. The large handwheel and specific design of the valve base are easing manual operation. End Connector The outlet end might be equipped by a quick Guillemin coupling type or by a flange PN for connection in DN00 or DN50 to the end user network. Irrimag Irrimag is a proportional technology meter, particularly well adapted to abrasive irrigation water. Irrimag is standard preequipped with Cyble technology. Cyble modules such as Cyble RF or Cyble pulser allow to remote read the index through Radio Frequency or to get access to flow-rate processing through pulse output. 9

20 Water Dimensions > DN00 with anti-frost sleeve Technical Characteristics Hydrant Type Number of outlets Connection to irrigation network Max. admissible pressure Testing pressure Weight DN Height B in DN00 or DN50 DN00 or DN50 PN With or without anti-frost height 0 bar 3 bar DN00: 7 kg (0 kg with anti-frost sleeve) DN50: 0 kg (75 kg with anti-frost sleeve) 700 with anti-frost sleeve 350 without anti-frost sleeve 700 with anti-frost sleeve 380 without anti-frost sleeve > DN50 with anti-frost sleeve Meter Irrimag DN00 Irrimag DN50 Maximum operating flow-rate 00 m 3 /h 500 m 3 /h Maximum admissible error +/- 5% from 8 m 3 /h to 00 m 3 /h +/- 5% from 0 m 3 /h to 500 m 3 /h Starting flow 3 m 3 /h 7.5 m 3 /h Index capacity m 3 Pressure Regulator DN00 DN50 Version Regulator (not closing in absence of flow) or stabilizer (closing in absence of flow) Adjustment values (PAC) bar 3--, , to be selected among to be selected among Regulation range - 0 /, x PAC + 0,5 (for flow-rates above Min operating fow-rate) - 0 /,3 x PAC (stabilizer version in absence of flow for Pdownstream-PAC < 7bar) Minimum operating flow-rate l/s 5 l/s Minimum operating pressure PAC + bar Flow Limiter DN00 DN50 Adjustment values (NL) l/s 7(5)-9(30)-0(35)-(0)-(50)- (50)-8(0)-0(70) (m 3 /h) 7(0)-(75) to be chosen among 3(80)-5(90)-30(00) 35(0) to be chosen among Limitation range 0/, x NL Max. differential pressure Class ( bar) Accessories Hydrant and Outlet End connection Automatic purge valve for hydrant uick coupling key tool flange DN00 or / coupling Guillemin type optionnal optionnal flange DN50 or coupling Guillemin type Head Guillemin Coupling 3 Flow Limiter Pressure regulating device 5 Meter Anti-Frost sleeve 7 Base Conditions d installation/montage > Tighten hydrant body after assembly on the network under pressure (concrete tubing with gravels, supporting, ). > In case of purge valve use, ensure that water flowing is possible. > Allways purge the network before assembly of the outlet, re-use of body outlet obturator bolts and nuts is possible. 0

21 B Hydrant Head Loss Global headloss of a B hydrant Example: B hydrant equipped with > Hydrant body base DN00 > Irrimag meter DN00 > Pressure regulator DN00 > Flow limiter DN00 at l/s Head loss calculation Individual headloss values: > Hydrant body DN00 = 0,0 > Irrimag DN00 = 0,05 > Pressure Regulator = 0,3 > Flow limiter =,0 > Total head loss,88 decibar > Flow limiter DN m 3 /h l/s > Pressure regulator DN00 > Pressure regulator DN mm mm m 3 /h l/s m 3 /h l/s

22 Water > Pressure stabilizer DN mm 50 mm m 3 /h l/s > Irrimag DN00-50 > B hydrant body (full opening) mm 50 mm 3,5,5 0,8 0, 0, BASE DN00 BASE DN m l/ 0, 0, m 3 /h l/s > Pressure variation at the hydrant outlet The sketch below is showing the pressure variation at the end user connection versus flow-rate, considering various outlet options: with or without flow limiter, Regulated downstream pressure (PAR), PAC + 0,5 P AC R' R S' S R S : Without flow limiter RST : With flow limiter NL : Nominal flow-rate of the limiter P AC : setpoint downstream pressure m 3 /h, NL T, NL l/s

23 Hydrant type B dimensions DN with anti-frost sleeve 350 without anti-frost sleeve Head Guillemin coupling 3 Flow limiter Pressure regulating device 5 Meter Anti-frost sleeve 7 Base dimensions DN with anti-frost sleeve 380 without anti-frost sleeve

24 Water Hydrant type A A outlet DNP5 outlets DNP5 3 Inlet DNB5, DNB80, or DNB00 Hydrant reference Tag Description Inlet DNB Outlet DNP Reference ++3 A Hydrant body with anti-freeze height 5 x A Hydrant body with anti-freeze height 80 x A Hydrant body with anti-freeze height 00 x A Hydrant body (short height) 5 x A Hydrant body (short height) 80 x A Hydrant body (short height) 00 x A Hydrant body (short height) 50 x

25 Hydrant type B A outlet DNP5 B outlet DNP00 outlets DNP00 3 Inlet DNB00 or DNB50 Hydrant reference Tag Description Inlet DNB Outlet DNP Reference ++3 B Hydrant body with anti-freeze height 00 x B Hydrant body with anti-freeze height 50 x B Hydrant body (short height) 00 x B Hydrant body (short height) 50 x Accessoires Tag Description Inlet DNB Outlet DNP Reference Y reducer DN00 -> two outlets DN5 00 x reducer DN00 -> one outlet DN5 00 x

26 Water A outlet DN5 5 7 Outlet main reference Tag Description Reference A outlet DN5 TUBAE Water meter Tag Description Reference with bypass meter DN5 SC= 0 m 3 /h H78 without bypass meter (obturator) H00 Pressure regulating device (PAC) Tag Description Reference 5 Adjustable cartridge 3/ bars adjusted at 3 bars HSIEGRR + HCART5 3/ 3B 5 Adjustable cartridge 3/ bars adjusted at 3,5 bars HSIEGRR + HCART5 3/ 3,5B 5 Adjustable cartridge 3/ bars adjusted at bars HSIEGRR + HCART5 3/ B 5 Adjustable cartridge 3/ bars adjusted at,5 bars HSIEGRR + HCART5 3/,5B 5 Adjustable cartridge 3/ bars adjusted at 5 bars HSIEGRR + HCART5 3/ 5B 5 Adjustable cartridge 3/ bars adjusted at bars HSIEGRR + HCART5 3/ B 5 Adjustable cartridge / bars adjusted at bars HSIEGRR + HCART5 / B 5 Adjustable cartridge / bars adjusted at 7,5 bars HSIEGRR + HCART5 / 7,5B 5 Adjustable cartridge / bars adjusted at 9 bars HSIEGRR + HCART5 / 9B 5 Adjustable cartridge / bars adjusted at 0 bars HSIEGRR + HCART5 / 0B 5 Adjustable cartridge / bars adjusted at bars HSIEGRR + HCART5 / B 5 without cartridge (obturator) H00 Flow limiter (NL) Tag Description Reference 5 m 3 /h (.5 L/s) H m 3 /h ( L/s) H m 3 /h (3 L/s) H m 3 /h ( L/s) H m 3 /h (5 L/s) H m 3 /h ( L/s) H m 3 /h (7 L/s) H m 3 /h (7.5 L/s) H m 3 /h (9 L/s) H m 3 /h (0 L/s) H m 3 /h ( L/s) H without limiter H00 Accessories Tag Description Reference 7 coupling «Guillemin» type H007

27 B outlet DN Outlet main reference Tag Description Reference Tubulure B DN00 TUBBE Water meter Tag Description Reference with bypass meter DN00 SC= 80 m 3 /h H78 without bypass meter (obturator) H00 Pressure regulating device (PAC) Tag Description Reference 5 3 bar H0 + H ,5 bar H0 + H bar H0 + H bar H0 + H bar H0 + H bar H0 + H bar H0 + H bar H0 + H without pressure stabilizer (obturator) H07 Flow limiter (NL) Tag Description Reference 5 m 3 /h (7 L/s) H m 3 /h (9 L/s) H m 3 /h (0 L/s) H m 3 /h ( L/s) H m 3 /h ( L/s) H m 3 /h (7 L/s) H m 3 /h ( L/s) H without limiter H00 Accessories Tag Description Reference 7 coupling «Guillemin» type H08 7

28 Hydrant type B 5a 3 Outlet DNP00 or DNP50 5b Outlet DNP00 or DNP50 Inlet DNB00 or DNB50 Hydrant reference Tag Description Inlet DNB Outlet DNP Reference ++3 B Hydrant body with anti-freeze height 00 x BRL B Hydrant body with anti-freeze height 50 x BRL00 +3 B Hydrant body (short height) 00 x BRL00 Water meter Tag Description Inlet DNB Outlet DNP Reference IRRIMAG DN00 SC= 00 m 3 /h IRRI00TVM Flow limiter (NL) Tag Description Inlet DN Outlet DN Reference 5b 5 m 3 /h (7 L/s) H b 30 m 3 /h (9 L/s) H b 35 m 3 /h (0 L/s) H a 0 m 3 /h ( L/s) H a 50 m 3 /h ( L/s) H a 0 m 3 /h (7 L/s) H a 75 m 3 /h ( L/s) H Pressure regulating device (PAC) Tag Description Inlet DN Outlet DN Reference 3 bar H bar H bar H bar H bar H bar H bar H bar H Accessories Tag Description Inlet DN Outlet DN Reference 7 coupling «Guillemin» type H03 About Itron Inc. Itron Inc. is a leading technology provider to the global energy and water industries. Our company is the world s leading provider of metering, data collection and utility software solutions, with nearly 8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water. Our products include electricity, gas and water meters, data collection and communication systems, including automated meter reading (AMR) and advanced metering infrastructure (AMI); meter data management and related software applications; as well as project management, installation, and consulting services. To know more, start here: For more information, contact your local sales representative or agency., Boulevard Pasteur 7500 Haguenau France Phone: Fax: Copyright 00, Itron. All Rights Reserved. - Itron reserves the right to change these specifications without prior notice. WA EN-05.0

MONOVAR is the energy dissipating valve.

MONOVAR is the energy dissipating valve. MONOVAR is the energy dissipating valve. Features Extremely simple design (patented) Excellent cavitation characteristics Very accurate flow or pressure control Manual or automatic control Suitable for

More information

CONTROL BALL VALVES NPS 6 28 Class

CONTROL BALL VALVES NPS 6 28 Class CONTROL BALL VALVES NPS 6 28 Class - 900 APPLICATION Control Ball Valves are designed to control working medium parameters (pressure, flowrate) by throttling flow at pipelines. Depending on their application

More information

Available in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class B multi-jet turbine meter for commercial and industrial applications.

Available in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class B multi-jet turbine meter for commercial and industrial applications. Multimag TM Multi-jet Turbine Water Meter DN 25 to DN 50 mm haracteristics Velocity type meter Direct magnetic transmission lass ISO 4064 vailable in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

Liquid filters _ 302. Deaerators. Product Bulletin

Liquid filters _ 302. Deaerators. Product Bulletin Liquid filters Deaerators _ 32 Product Bulletin WWW.VAF.NL Introduction VAF Instruments liquid filters/deaerators are used in combination with VAF flowmeters. The use of liquid filters protects downstream

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

AUTOMATIC CONTROL VALVES BY RAPHAEL

AUTOMATIC CONTROL VALVES BY RAPHAEL CONTROL VALVES AUTOMATIC CONTROL VALVES BY RAPHAEL RAF PRESSURE RAF PRESSURE offers the possibility of controlling an upstream pressure, a downstream pressure or both. RAF PRESSURE REDUCING reduces and

More information

FLOW CONTROL. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS

FLOW CONTROL. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS www.rwc.co.uk. PRODUCT GUIDE 2018 WATER CONTROLS FOR A MODERN WORLD TEMPERATURE CONTROL FLOW CONTROL HEATING SYSTEM COMPONENTS WASHROOM SYSTEMS HEATING & COOLING DISTRIBUTION SYSTEMS PLUMBING SYSTEMS Flow

More information

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions - Plastic Hydraulic/Electric Control Valves Water Control Solutions Plastic Hydraulic/Electric Control Valves for residential, commercial and agricultural irrigation systems. The BERMAD plastic control

More information

Residential Water Meters

Residential Water Meters EnergyMetering Residential Water Meters Multi-jet wet dial meters Multi-jet dry dial meters Positive displacement meters AMR-technology All that counts. Technology of the highest standard Quality and reliability

More information

TECHNICAL MANUAL MT029

TECHNICAL MANUAL MT029 Ed.2008 Rev.B REFLUX 919 TECHNICAL MANUAL MT029 INSTALLATION, COMMISSIONING AND MAINTENANCE ISTRUCTIONS TABLE OF CONTENTS Chapter Page 1. AIM 4 2. DESCRIPTION OF THE VALVE 4 3. IDENTIFICATION OF THE VALVE

More information

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid

More information

ULTRASONIC HEAT METER

ULTRASONIC HEAT METER MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.

More information

tprime TM Series 280T

tprime TM Series 280T MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.

More information

SSV SL-022 Safety Shut-off Valve

SSV SL-022 Safety Shut-off Valve SSV SL-022 Safety Shut-off Valve These shut-off valves are designed for transmission and distribution networks, as well as commercial and industrial use. KEY BENEFITS High accuracy shut-off Low pressure

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03 Double check valves for medium hazard rated applications Flanged and roll grooved end connections FEATURES GENERAL APPLICATION The DC0 provides protection from both backsiphonage and backpressure of the

More information

LS Rotary Piston flow meter

LS Rotary Piston flow meter LS Rotary Piston flow meter Model LS rotary piston flow meter (hereafter for short called flow meter) is a kind of volumetric flow-measuring instrument, mainly used to measure volume flow of liquid. Its

More information

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600 STUF-280W Features: Wear-free ultrasonic measurement. No moving parts. No maintenance needed Proprietary robust sensor design. Not impacted by water impurity Counts each drop. Very low start flowrate Excellent

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

CBV Series. Circuit Balancing Valves

CBV Series. Circuit Balancing Valves CBV Series Circuit Balancing Valves FILE NO: 36.10IN DATE: Dec. 15, 2010 SUPERSEDES: 36.10IN DATE: Nov. 05, 2009 CBV Series Circuit Balancing Valves - Introduction Circuit balancing valves (CBVs) combine

More information

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48 DOROT PLASTIC VALVES PRINCIPLE OF OPERATION -Way Control System The main valve is controlled by a manually, electrically or pressure actuated selector that: (1) Introduces the upstream pressure or an external

More information

Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER

Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER H5000: The World s Most Accurate Commercial Hybrid Meter The H5000 s true hybrid design has the widest measuring range of any water metering

More information

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation. Page 1 of 7 Application The (High Corrosion Resistant) Valves are particularly designed and manufactured for automatic balancing in Industrial applications. An integral part of the Valve is the ALPHA Cartridge,

More information

Initial Start-Up. What We Will Cover

Initial Start-Up. What We Will Cover 03 03 Initial Start-Up Once you have a firm grasp on the components of the assembly head and drip line, it s time for the initial installation. When installing your head assembly, there are a few different

More information

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions High Performance Plastic Valves ater Control Solutions 100 Series hyflow High Performance Plastic Hydraulic Control Valves Features and Benefits Durable industrial grade valve design and construction uses

More information

Delta Commercial & Industrial Rotary Meter

Delta Commercial & Industrial Rotary Meter Delta Commercial & Industrial Rotary Meter Itron's Delta range of rotary gas meters comprises innovative and high quality products. Characterized by compact dimensions and easy maintenance, the Delta

More information

PRESSURE REDUCING VALVES

PRESSURE REDUCING VALVES 14.01 Part No. 536 536 WRAS APPROVED BRASS BODY WITH BSP THREADED CONNECTIONS SUITABLE FOR WATER & AIR The 536 pressure reducing valve is a economical and reliable solution for water and air applications.

More information

aquaconcept Product features Customer benefits

aquaconcept Product features Customer benefits aquaconcept The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration into your specific

More information

Safety Shut-Off Valve HON 711 S2

Safety Shut-Off Valve HON 711 S2 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications Safety device in gas pressure regulating stations Applicable for use with natural gas according

More information

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

ERHARD is a company of. Datasheet ERHARD ball valve

ERHARD is a company of. Datasheet ERHARD ball valve ERHARD is a company of Datasheet The economical solution for high pressures and high flow rates Especially with high flow velocities up to 5 m/s and pressure ratings up to PN 4, the offers the ideal and

More information

TOPAS PMW-basic. Customer benefits. Product features

TOPAS PMW-basic. Customer benefits. Product features TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration

More information

Pressure independent combined control and balancing valves with independent EQM characteristics

Pressure independent combined control and balancing valves with independent EQM characteristics Combined control & balancing valves TA-FUS1ON-P Pressure independent combined control and balancing valves with independent EQM characteristics Pressurisation & Water Quality Balancing & Control Thermostatic

More information

BIOVENT. Hygienic Valve

BIOVENT. Hygienic Valve BIOVENT BIOVENT Committed to perfection in every detail Powerful valve actuator BIOVENT control valves are usually combined with pneumatic multi-spring ARCAPAQ actuator type 813. Not only is it cost effective,

More information

Servotronic Digital 615 Series

Servotronic Digital 615 Series Servotronic Digital 615 Series Proportional Technology www.asco.com PRESSURE CONTROL: 615 SERIES SERVOTRONIC Digital Servotronic Digital Greater versatility in automated production processes: Due to electronics,

More information

Float valve with balanced single seat Mod. ATHENA

Float valve with balanced single seat Mod. ATHENA Float valve with balanced single seat Mod. ATHENA The ATHENA is an equilibrium, single seat upstream pressure balanced float valve, which automatically controls the constant level of a tank or reservoir,

More information

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15

More information

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions Hydraulic Control Valves 900 series - Hydrometers Water Control Solutions Company Profile Experience and proven results have made BERMAD synonymous with water, and other fluid, control and management.

More information

LBTC Series Positive Displacement Rotary Vane Flow Meters

LBTC Series Positive Displacement Rotary Vane Flow Meters LBTC Series Positive Displacement Rotary Vane Flow Meters Summary LBTC Series positive displacement rotary vane flow meters are independently designed and manufactured by our company on the base of absorbing

More information

flow measurement solutions RIM10 series rotor insertion flowmeters

flow measurement solutions RIM10 series rotor insertion flowmeters flow measurement solutions RIM10 series rotor insertion flowmeters R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough for almost any challenge Spirax Sarco s RIM10 rotor insertion flowmeters

More information

Pressure reducing valves

Pressure reducing valves Pressure reducing valves Pilot Operated 25 Series The Spirax Sarco 25-Series regulators are a versatile family of self-acting pressure regulators with control pilots and interchangeable main valves for

More information

Dry Pillar Hydrant Type ADR with pre-set break. Technical Bulletin. code. General description

Dry Pillar Hydrant Type ADR with pre-set break. Technical Bulletin. code. General description Dry Pillar Hydrant Type ADR with pre-set break General description Type ADR with pre-set break off point and automatic shut-off in case of breakage to prevent water escape. Above ground section 360 rotational

More information

KLINGER BALLOSTAR KHE

KLINGER BALLOSTAR KHE KLINGER KHE 2-piece ball valves DN 0 (1/2" 8") www.klinger.kfc.at MF 01 KLINGER FLUID CONTROL Today for tomorrow As a subsidiary of the KLINGER Group, KLINGER Fluid Control has been developing, manufacturing

More information

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up

More information

Accumulator charging valves & kits

Accumulator charging valves & kits accumulator charging valves & kits HYDROTECHNIK UK LIMITED Accumulator charging valves & kits Minimess gas charging valves Nitrogen pressure regulators & charging devices Nitrogen accumulator gas charging

More information

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K Table of Contents Automatic Section Automatic Balance Valves Installation Operation Maintenance Instructions / Warranty Technical Information How To Order Coil Piping Packages Package Types How To Order

More information

Quantometer MZ. Description

Quantometer MZ. Description Quantometer MZ < High accuracy budget meter < Flow rate up to 10000 m 3 /h < Pressure range up to 100 bar < Equipped as standard with the cyble target. < Various options available: Low and high frequency

More information

SMA. Automatic Minimum Flow System PN 250-PN 400 ANSI look at info overview. 180 bar < < 400 bar

SMA. Automatic Minimum Flow System PN 250-PN 400 ANSI look at info overview. 180 bar < < 400 bar Automatic Minimum Flow System look at info overview PN 250-PN 400 ANSI 1500-2500 180 bar < < 400 bar 7 V R The Automatic Minimum Flow System SMA 63/64 is a protection device for pump protection. It automatically

More information

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67 VALVE FEATURES The resilient seat gate valve type is dedicated to the shut off of clear water and sewage water pipes. The motorization with the REGADA actuator allows the automation and the remote control

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Heating and Cooling Catalog

Heating and Cooling Catalog Heating and Cooling Catalog KNOWLEDGE TO SHAPE YOUR FUTURE At Itron, the phrase «Knowledge to shape your future» is more than a simple slogan. It s a fundamental tenet of who we are, and it helps define

More information

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2 8) KLINGER BALLOSTAR KHE 2-piece ball valves DN 15 0 (1/2" 8") www.klinger.kfc.at MF 01 KLINGER FLUID CONTROL Today for tomorrow As a subsidiary of the KLINGER Group, KLINGER Fluid Control has been developing,

More information

PRESSURE CONTROL VALVES SABS 198

PRESSURE CONTROL VALVES SABS 198 PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge

More information

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function FLOWCAL Automatic flow balancing valve with polymer cartridge 121 series REGISTERED BSI EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01141/11 NA Function The FlowCal automatic

More information

Hydrovar and Packaged Hydrovar

Hydrovar and Packaged Hydrovar Hydrovar and Packaged Hydrovar MOTOR MOUNT VARIABLE SPEED PUMP CONTROLLER AND INTEGRATED PUMP PACKAGES BRHYDROVAR R3 Goulds Water Technology Hydrovar and Packaged Hydrovar Hydrovar Variable Speed Drives

More information

Globe valves Shut-off check valve 200 AE/BE PN DN Globe valves Lift check valve 240 MT PN DN 10-50

Globe valves Shut-off check valve 200 AE/BE PN DN Globe valves Lift check valve 240 MT PN DN 10-50 Globe valves Shut-off check valve 200 AE/BE PN 10-160 DN 10-50 Globe valves Lift check valve 240 MT PN 10-160 DN 10-50 Admissible operating pressure [bar] at design temperature [ C] 1) Material PN -200-60

More information

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features Double check valves for medium hazard rated applications BSP screwed connections Features General application The DC03 provides protection from both backsiphonage and backpressure of the potable water

More information

ES-ISO ES-NEW GENERATION BACK PULL-OUT END SUCTION PUMPS

ES-ISO ES-NEW GENERATION BACK PULL-OUT END SUCTION PUMPS ES-ISO ES-NEW GENERATION BACK PULL-OUT END SUCTION PUMPS Conforms to ISO 2858 Conforms to ISO 5199 Optimized for capacity Efficiency as per Hydraulic Institute & Europump Norms Many product variants -

More information

AUTOMATIC CONTROL VALVES. TIS asia

AUTOMATIC CONTROL VALVES. TIS asia AUTOMATIC CONTROL VALVES VALVES DEDICATED TO THE WATER DISTRIBUTION NETWORK AND HYDROPOWER SECTOR WE DO NOT SELL JUST VALVES, WE SELL A SOLUTION FOR THE EFFICIENCY OF THE WATER NETWORK TIS asia MADE IN

More information

Process Industry. Diaphragm Seal Solutions

Process Industry. Diaphragm Seal Solutions Process Industry Diaphragm Seal R Overview Diaphragm Seal Systems Provide Protection to Ensure Safety, Reliability Diaphragm seal systems protect gauges from hot, viscous, contaminated or corrosive media.

More information

General information Gate valves

General information Gate valves General information Gate valves In 1957, Hawle invented the resilient-seated gate valve with multiple O-ring sealing of the valve spindle and had it patented. Today, this type of gate valve is the standard

More information

FIXED CONE VALVE. The flow is guided by the inner vanes, in order to decrease the vortex and the vibration;

FIXED CONE VALVE. The flow is guided by the inner vanes, in order to decrease the vortex and the vibration; BEI JI NG JOI NTFLOW SYSTEM CO. FI XEDCONEVALVE The Fixed cone Valve is typically operated by a manual, electric or hydraulic actuator mounted above the bevel gear. The bevel gear transmits torque to the

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

AMIAD "HydroTAF" FILTER SERIES

AMIAD HydroTAF FILTER SERIES AMIAD "HydroTAF" FILTER SERIES 2"/3" Hydraulic automatic filters for flow rates up to 50 m 3 /h (220 USgpm) This compact self-cleaning filter operates on water pressure and does not need any external source

More information

Venting valves. Valves. Manually actuated. Venting valves. Installation elements

Venting valves. Valves. Manually actuated. Venting valves. Installation elements Installation elements Venting Manually actuated Venting For manually venting small vacuum chambers Valve opens and closes easily by loosening/ tightening the screw cap FVB = Venting valve HA = Manually

More information

LCMass Series Mass Flow Sensor

LCMass Series Mass Flow Sensor LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006

More information

British Standard institute-bs Valve Standards

British Standard institute-bs Valve Standards BS 341-1:1991 Transportable gas container valves. Specification for industrial valves for working pressures up to and including 300 bar (REPLACED by BS EN 14189:2003), BS 341-3:2002), BS EN 849:1997),

More information

OLYMPUS. Gas Turbine Fuel Controls. Building of complete custom designed fuel systems. Single or serial production quantities

OLYMPUS. Gas Turbine Fuel Controls. Building of complete custom designed fuel systems. Single or serial production quantities OLYMPUS Gas Turbine Fuel Controls Gas Fuel Throttle Valve Liquid Fuel Throttle Valve Liquid Fuel Metering Pump Gas & Liquid Fuel Throttle Assemblies Building of complete custom designed fuel systems Single

More information

PB & PM Impact Crushers & Impact Mills. For top crushing performance

PB & PM Impact Crushers & Impact Mills. For top crushing performance PB & PM Impact Crushers & Impact Mills For top crushing performance Headquarters of BHS-Sonthofen The company BHS-Sonthofen, headquartered in Sonthofen, Germany, is an owner-operated group of companies

More information

Innovative Firefighting Products

Innovative Firefighting Products Innovative Firefighting Products TFT Offers Flow Efficient Water Supply and Innovative Appliance Solutions to Responders Worldwide Flow efficiency, a lightweight compact design, and long-term corrosion

More information

House Hydrant V1 FROST-FREE OUTDOOR WALL HYDRANT. aqu r FLUSH-MOUNT NON-FREEZE SELF-DRAINING.

House Hydrant V1 FROST-FREE OUTDOOR WALL HYDRANT. aqu r FLUSH-MOUNT NON-FREEZE SELF-DRAINING. House Hydrant V1 FROST-FREE OUTDOOR WALL HYDRANT FLUSH-MOUNT NON-FREEZE SELF-DRAINING www.aquorwatersystems.com Overview and Feature List HOUSE HYDRANT V1 - IN-WALL OUTDOOR FAUCET SYSTEM Flush-mounted

More information

VALVE WITH UV ELECTRIC ACTUATOR

VALVE WITH UV ELECTRIC ACTUATOR 762-763 VALVE WITH UV ELECTRIC ACTUATOR CHARACTERISTICS The 762-763+UV ball valve is dedicated to the automatic opening/shut-off of pipes carrying medium pressure unloaded industrial fluids. This full

More information

Automatic balancing valves ASV-PV DN (3rd gen.)

Automatic balancing valves ASV-PV DN (3rd gen.) Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance

More information

PRODUCT IDENTIFICATION & COMPANY

PRODUCT IDENTIFICATION & COMPANY TECHNICAL DATA SHEET PRODUCT NAME : FLOW METERS SECTION 1 PRODUCT IDENTIFICATION & COMPANY Product Name Flow Meters ( FLOWTECH & BLUE & WHITE) Supplier EZ Water Technology Address 1647 S, Main St. Suite

More information

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch. VA 500/ 520 Flow sensors for compressed air and gases incl. temperature Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) Even under pressure, the ow sensor VA

More information

ERHARD is a company of. Data sheet ERHARD needle valves

ERHARD is a company of. Data sheet ERHARD needle valves ERHARD is a company of Data sheet ERHARD needle valves ERHARD RKV needle valves The innovative needle valve with the four positive points Based on decades of experience in the design and production of

More information

PIPELINE INJECTION PRODUCTS

PIPELINE INJECTION PRODUCTS PIPELINE INJECTION PRODUCTS DURABLE & RELIABLE SOLUTIONS PIPELINE INJECTION PUMP GP-10 & GP-1 SERIES Flows up to: 210 GPM / BPH / 7,20 BPD (nominal flow) BUSHINGS BACK PULL OUT SEAL HEAD DRIVER SHAFT DRIVEN

More information

Expert tip: UNPARALLELED PROTECTION AND VERSATILITY UNDERGROUND IRRIGATION PROGRAMMABLE SOLENOID CONTROL UNIT 1 F. PROGRAMMABLE SOLENOID VALVE.

Expert tip: UNPARALLELED PROTECTION AND VERSATILITY UNDERGROUND IRRIGATION PROGRAMMABLE SOLENOID CONTROL UNIT 1 F. PROGRAMMABLE SOLENOID VALVE. Masters of Water PROGRAMMABLE SOLENOID Expert tip: The new detachable control units have been redesigned to meet IP 68 standard: the highest level of filter against water, grit and dirt. The new units

More information

Static Balancing Valve

Static Balancing Valve Static Balancing Valve Series W-JP45X-16Q Sizes: DN50-DN300 APPLICATION The Series W-JP45X Static Balancing Valve is designed for flow balancing in cooling, heating or process water systems. Its measuring

More information

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE Table of Contents Features, Applications and Specifications...3 Installation...4 Operation...5 Testing Procedure...6

More information

Gas pressure regulator R 100 / R 100U / R 100UD

Gas pressure regulator R 100 / R 100U / R 100UD Gas pressure regulator R 100 / R 100U / R 100UD Product information Subject to modifications! Reprint prohibited! Table of Contents Application, Characteristics, Technical Data 4 Application 4 Characteristics

More information

MUELLER ECCENTRIC PLUG VALVE

MUELLER ECCENTRIC PLUG VALVE MUELLER INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS 1 MUELLER System Design The life of the valve is dependent on its application, frequency of use and freedom from misuse. The properties of the

More information

Sleeve Valves Energy Dissipaters

Sleeve Valves Energy Dissipaters Sleeve Valves Energy Dissipaters Engineering Creative Solutions for Fluid Systems Since 1901 A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years

More information

VALVES WITH UV ELECTRIC ACTUATOR

VALVES WITH UV ELECTRIC ACTUATOR 505-507 VALVES WITH UV ELECTRIC ACTUATOR CHARACTERISTICS The 505+UV and 507+UV cast iron ball valves are dedicated to the automatic opening/shut-off of pipes carrying low pressure unloaded common fluids.

More information

VBK 2596/12E/RSF. Thickness and Width Gauge for Strip and Profile. Operating- & Service Instructions. (with lateral guide rollers)

VBK 2596/12E/RSF. Thickness and Width Gauge for Strip and Profile. Operating- & Service Instructions. (with lateral guide rollers) Thickness and Width Gauge for Strip and Profile (with lateral guide rollers) VBK 2596/12E/RSF Operating- & Service Instructions erstellt am 5.2.1998 freigegeben am Bemerkungen Rev.01 Seiten:16 Name: Rietdorf

More information

ERHARD is a company of. Datasheet ERHARD ERK tilting-disc check valve

ERHARD is a company of. Datasheet ERHARD ERK tilting-disc check valve ERHARD is a company of Datasheet ERHARD ERK tilting-disc check valve The universal check valve with double excentric valve disc A key component of the is the valve disc which has a freely oscillating,

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

ANDERSON GREENWOOD TYPE 4410 SIDE ENTRY ATMOSPHERIC VACUUM RELIEF VALVES

ANDERSON GREENWOOD TYPE 4410 SIDE ENTRY ATMOSPHERIC VACUUM RELIEF VALVES Weight or spring loaded valves with a side inlet capable of high capacity vacuum relief. Designed to work closer to a tank's MAWV, increasing productivity, reducing emissions and product evaporation FEATURES

More information

Air service units filters, regulators and lubricators

Air service units filters, regulators and lubricators filters, regulators and lubricators Legris offers an extensive range of filters, regulators and lubricators, including individual units and combinations. s - eliminate dust and coagulation from compressed

More information

Sentronic PLUS 614 Series

Sentronic PLUS 614 Series Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately

More information

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF VERSION UF-5xx d INSTALLATION MANUAL ISO 9001:2008 CONTENTS Page INTRODUCTION... 3 1. SAFETY INSTRUCTIONS... 4 2. MOUNTING PREPARATION... 4 3. MOUNTING REQUIREMENTS...

More information

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

CT3202.0_01 EN February 2018

CT3202.0_01 EN February 2018 UNDERFLOOR HEATING / RADIATOR HEATING COMPACT BRASS MODULAR MANIFOLDS (centre distance 37 mm) CT3202.0_01 EN February 2018 o o o Super compact: e.g. 11 ways (version code 3211.06.10) in just 60 cm; Insertion

More information