flow measurement solutions RIM10 series rotor insertion flowmeters

Size: px
Start display at page:

Download "flow measurement solutions RIM10 series rotor insertion flowmeters"

Transcription

1 flow measurement solutions RIM10 series rotor insertion flowmeters

2 R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough for almost any challenge Spirax Sarco s RIM10 rotor insertion flowmeters combine the volumetric, mass and energy flow monitoring of gases, liquids and steam into one device. The RIM10 is hot tap compatible making it versatile for installation into virtually any application; ultimately it avoids the expense and unnecessary disruption to critical processes often associated with installation of flowmetering equipment. The sensor is easy to install and maintain in pipelines ranging from 3" to 80" (75 mm to 2000 mm) under full flow conditions without process shutdown. The RIM10 is especially economical for large pipe diameters of 8" (300 mm) and upwards, where inline installation costs may be prohibitive. Even when the RIM10 has been selected for use in smaller pipeline sizes, the low maintenance liability makes the total cost of ownership attractive. Turndown of 25:1, plus outstanding linearity at low flowrates is achieved through the six field-installable rotor assemblies constructed of high grade stainless steel with different turbine pitches. The benefit of this technology is the accuracy you get, even in the more difficult applications, delivering reliable performance with high pressure flows and high process temperatures up to 750 F (400 C). The RIM10 multi-variable electronics also incorporate an RTD to provide a compensated mass flowrate of liquid, gas and steam, so any fluctuations in pressure can be taken into account to consistently provide error-free flowmetering.

3 spiraxsarco.com/us Introducing the RIM10 range As well as being able to set the velocity range by choosing from six rotor pitches, you can choose from three RIM10 types to ensure that you select the correct flowmeter to best suit your application. The key differentiators are highlighted adjacently. RIM RIM RIM Maximum temperature 400 F (204 C) 600 F (306 C) 750 F (400 C) Maximum pressure 125 psig (8.6 bar g) 2000 psig (138 bar g) Flange rating Available pipe sizes 3" to 20" (75 mm to 500 mm) 3" to 80" (75 mm to 2000 mm) 3" to 80" (75 mm to 2000 mm) Seal type Ethylene-Propylene Elastomer Swagelok Grafoil 3

4 R I M 1 0 Some of the products may not be available in certain markets.

5 spiraxsarco.com/us A single device that measures all process variables to provide outstanding accuracy Key features of the RIM10 rotor insertion flowmeter: Rugged insertion-style mounting in pipeline sizes of 3" to 80" (75 mm to 2000 mm) Fixed mount or hot-tappable configurations (including outdoors) Key benefits Typical savings compared to full-bore flowmeters: - 80% for the 24" (600 mm) pipelines and - 50% for 10" (250 mm) pipelines. Suitable for installation and servicing under full flow conditions. Unique, low-mass rotor machined from a solid block of stainless steel No welds for maximum service life and flow sensitivity. The positioning of the sensor head within the pipeline s flow profile, plus six field-installable rotor assemblies each comprising a calibrated cartridge Fits where other technologies cannot perform Highly accurate. Outstanding for low-flowrate (Re > 5,000) and wide-turndown applications. Minimal flow obstruction Negligible pressure drop and energy loss. Excellent pressure / temperature limitations Process pressure up to psi g (137.8 bar g) and Process temperatures up to 750 F (400 C). Bidirectional rate / total (optional), with the rotor calibrated Forward and reverse flow. Advanced algorithms developed from independent research and flow standards Delivering accurate measurements for excellent energy management. Set-up and running quickly with simplified commissioning Through an easy to use local display or remote configuration and monitoring via Ethernet / HTTP web interface. Simultaneous measurement signals by Ethernet, Modbus RTU via RS485 serial, Modbus TCP / IP Suitable for many applications. FM, ATEX and CE approval pending Fit for purpose at the standard required for your business. 5

6 R I M 1 0 Whether for indoor or outdoor use, in fixed mount or hot tap installation, there is a RIM10 configuration for your application, with a range of three options: RIM10-600, RIM and RIM Spirax Sarco's RIM10 rotor insertion flowmeters provide you with the management information you need to operate your plant at peak efficiency by helping you pinpoint where the biggest consumers of energy are located so you can monitor the associated costs and make adjustments across the plant to save energy. Since the RIM10 is also easy to install under full flow conditions and without process shutdown, a limited numbers of flowmeters could cycle through many locations for extra cost efficiency. How the RIM10 works Installation The RIM10 s stainless steel rotor is accurately positioned and the kinetic energy in the fluid stream causes it to spin in direct proportion to flow. As each turbine blade rotates past the magnetic pickup coils, the magnetic field is broken which generates a small voltage pulse that can be translated into flowrate data. The integral RTD provides real-time temperature monitoring for sensor calibration and accurate flowrate monitoring, as well as for the flow computer to output a true density-compensated mass flow signal accurate to ±1.5% of rate with liquids and ±2.0% of rate with gas and steam. The installation location should be selected to minimize turbulence and swirl. The extent of these flow disturbances depends upon the piping configuration. Valves, elbows, pumps and other piping components may add disturbances to the flow. The rotor insertion flowmeter may be installed in vertical, horizontal, or angled pipe sections, but not mounted upside-down. The tap size is 48 mm (1 4") minimum diameter. For liquid service, the fluid must completely fill the pipe. For more details of how the RIM10 rotor insertion flowmeter can help you take control of your energy environment, contact your Spirax Sarco Sales Engineer today. Alternatively visit our website at

7 spiraxsarco.com/us Hot tapping Accessories The RIM10 can be installed quickly and easily under full flow conditions without process shutdown. First, a sock-o-let is welded to the line, then a flange to the sock-o-let. A gate valve is mounted to the flange and a hot tap enters the pipeline. The flowmeter is then installed on the valve and the measuring element extended into the pipeline with the aid of a reference scale. The RIM10 requires only 10 pipe diameters of straight length after a single bend in the pipeline. For a detailed layout of the pipeline requirements based on pipeline configurations, see the Installation and Maintenance Instructions (IM-P US) supplied with the product; alternatively search our website to download or view at your convenience: Typical pipeline requirements for the different technologies are shown below. Comparison of pipe requirements for different flow technologies on saturated steam Orifice plate Vortex RIM10 TVA Flow Flow Flow Flow 10D 6D 15D 3D 20D The RIM10 requires only ten pipe diameters of straight pipe upstream and five downstream, making it a compact ideal choice for any application and saves time and money on installation costs and downtime. 5D 5D 7D D = Pipe diameter The RIM10 is a trusted, field proven member of the well established and comprehensive family of Spirax Sarco flowmeters that has been used in industrial flowmetering applications for more than 30 years. As it may be specified with several accessories to accommodate different applications, the RIM10 is one of the most adaptable flowmeters available. Gate valve for the RIM This 2" (DN50) double-flanged, raised-face, full-port gate valve enables the flow sensor to be inserted and removed from the pipe under full-flow conditions. Isolation valve for the RIM (included) A 2" (DN50) full-port bronze gate valve makes this model fully installable and maintainable under full-flow conditions. Pressure tap and bleed valve Standard ¼" NPT pipe nipple with ¼" stainless steel bleed valve provides connections for mounting an optional pressure transmitter. Model PT pressure transmitter (optional) This instrument can be mounted to the ¼" NPT bleed valve connection, eliminating the need for a separate pressure tap. A 4-20 ma output, scaled to the desired pressure range, is provided. All pressure transmitters include a siphon tube, bleed valve, plug, nipple, and tee. Remote mount electronics The RMT option includes 100 ft (30 m) of signal cable and U-bolts. A ¾" NPT conduit connection is provided. FM approval Pending: FM Class I, Division 2, Groups A, B, C and D; Classes II, III, Division 2, Groups F and G NEMA 4 x locations; ATEX and CE. 7

8 spiraxsarco.com/us US Regional Offices Northeast 500 W Wilson Bridge Road Suite 135 Worthington, OH Phone: Mid-Atlantic 4647 Saucon Creek Road Suite 102 Center Valley, PA18034 Phone: Southeast 400 Northeast Drive, Unit O 2021 Business Center Columbia, SC Phone: Southwest 203 Georgia Avenue Deer Park, TX Phone: West 8141 E. Kaiser Blvd Suite 311 Anaheim Hills, CA Phone: Miller Drive Longmont, CO Phone: Midwest 1500 Eisenhower Lane Suite 600 Lisle, IL Phone: Spirax Sarco, Inc Northpoint Blvd., Blythewood, SC T or F SPB1057 Copyright 2012 Spirax Sarco is a registered trademark of Spirax-Sarco Limited printed in USA 4/2012

control & instrumentation solutions RIM10 series rotor insertion flowmeters

control & instrumentation solutions RIM10 series rotor insertion flowmeters control & instrumentation solutions RIM10 series rotor insertion flowmeters E X P E R T I S E S O L U T I O N S S U S T A I N A B I L I T Y R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough

More information

The AEL6 series smart electric actuator

The AEL6 series smart electric actuator controls and instrumentation solutions The AEL6 series smart electric actuator A E L 6 AEL6 series Our newly launched smart electric actuator The AEL6 series of smart electric linear actuators are suitable

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

RIM20 Rotor Insertion Flowmeter

RIM20 Rotor Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems 9303 W. Sam Houston Parkway, Houston, TX 77099 INTRODUCTION The insertion turbine meter is well suited for

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

RUN ACCUM. TOTAL STOP BAT LOW HIGH

RUN ACCUM. TOTAL STOP BAT LOW HIGH TURBOPULSE TURBINE FLOWMETER INSTRUCTION MANUAL gal RUN ACCUM. TOTAL STOP BAT LOW HIGH RESET > PROGRAM ENTER ACCUM TOTAL ^ RATE TOTAL TP050 TABLE OF CONTENTS 1. INTRODUCTION Overview 1 1.1 Model number

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to

More information

BARTON 7400 Precision Gas Turbine Flow Meters

BARTON 7400 Precision Gas Turbine Flow Meters TECHNICAL SPECIFICATIONS BARTON 7400 Precision Gas Turbine Flow Meters BARTON Model 7400 Precision Turbine Flow Meters are designed for gas service in a wide range of industrial, commercial, pipeline and

More information

F-2500 SERIES VORTEX METER

F-2500 SERIES VORTEX METER F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

LCMass Series Mass Flow Sensor

LCMass Series Mass Flow Sensor LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller

More information

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment VORTAB FLOW CONDITIONERS For Flow Meters, Pumps and Other Flow Profile Critical Equipment Reduce flow meter straight-run requirements into just a few diameters Balance pump inlet flow to eliminate premature

More information

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs s Meriam s Flow Sensors are lab-tested and field-proven flow elements perfect for gas, liquid or steam service. With thousands in use worldwide, the continues to be the right choice when ease of installation,

More information

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed

More information

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage

More information

Fundamental Training. Flow Con t

Fundamental Training. Flow Con t Fundamental Training Flow Con t 1 Contents Topics: Slide No: Velocity flow meters 3-11 Mass flow meters 12-17 Displacement meters 18 Exercise 19-20 2 Velocity Meter Magnetic Flowmeter Faraday s Law of

More information

Propeller. Flowmeter. Technology. For the Real World.

Propeller. Flowmeter. Technology. For the Real World. Propeller Flowmeter Technology For the Real World. Propeller Flowmeters Long-lasting Stainless Steel Ball Bearings. Factory lubricated and protected from flow stream. Epoxy-Coated Carbon Steel Body. All

More information

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BULLETIN 20-5100-68 BYPASS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BYPASS ROTOMETERS SK bypass Rotameter systems are designed for the accurate measurement of fluid rate of flow in pipelines 11/2

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas

More information

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT) Gas and Liquid Measurement Catalog SOLUTIONS FOR: - PRODUCTION - REFINERIES - DISTILLERY - TRANSPORTATION AND STORAGE - OIL DEPOTS - DISTRIBUTION. Engineered Solutions. ORIFICE METERS ULTRASONIC METERS

More information

Direct Contact Desuperheaters

Direct Contact Desuperheaters Control Description Spirax Sarco direct contact desuperheaters reduce the temperature of superheated steam to produce steam temperatures approaching saturation temperature to cool the superheated steam,

More information

Flow Measurement Catalog

Flow Measurement Catalog www.spiraxsarco.com/us Flow Measurement Catalog Flow Measurement Catalog Product Catalog Sixth Edition 1 Copyright 2011 by Spirax Sarco, Inc. Flow Measurement Product Catalog Sixth Edition All rights

More information

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide Measurement Products Measurement made easy Swirl flowmeters FS4000 Simply fitting your purpose Application guide Swirl flowmeters Serving your application Exceeding your expectations about modern field

More information

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions 1930051/2 IM-P193-03 MI Issue 2 TFA meter for Saturated Steam Service Installation and Maintenance Instructions This guide must be read in conjunction with the Installation and Maintenance Instructions

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

Model Turbo-Bar General Specification

Model Turbo-Bar General Specification 11.4 11.4 11.4 11.4 Model General Specification TMP-600/60S TMP-700 TMP-800/80S TMP-910/960 Features! Fluid types: liquid, gas or steam! Pipe sizes: 3 to 80 in. (80 to 000 mm)! Rugged construction! Interchangeable

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

Hydro-Flow Model 3100

Hydro-Flow Model 3100 Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

MODEL 1100 TURBINE FLOW METER

MODEL 1100 TURBINE FLOW METER MODEL 1100 TURBINE FLOW METER INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Phone: 800.433.5263 Fax: 800.245.3569 www.hedland.com 2 OPERATIONAL START-UP Fluid entering

More information

Vortex Flow Meter Model DVH

Vortex Flow Meter Model DVH Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Pressure reducing valves

Pressure reducing valves Pressure reducing valves Pilot Operated 25 Series The Spirax Sarco 25-Series regulators are a versatile family of self-acting pressure regulators with control pilots and interchangeable main valves for

More information

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:TRQSMAN16 Table of Contents Contents Table of Contents... 2

More information

VAD Variable Area Desuperheaters

VAD Variable Area Desuperheaters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell Transmitters Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell Oldest design, developed during WW 2. Can be used for flow, level, and pressure, vent low side. Several ranges 0 to

More information

Vortex Flowmeter Model DVE

Vortex Flowmeter Model DVE Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement Velocity Averaging Sensors True Performance in Measurement ...Advanced DP Measurement The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology,

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

Gauges, Sight Glasses and Vacuum Breakers

Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure

More information

Rosemount Orifice Series Differential Pressure Flow

Rosemount Orifice Series Differential Pressure Flow Rosemount Orifice Series Differential Pressure Flow Innovative Offering for Better Measurement Revolutionizing the Industry Workhorse Orifice Plate Technology It s no coincidence that orifice plates are

More information

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower

More information

Model 1100 Turbine Flow Meter

Model 1100 Turbine Flow Meter Model 1100 Turbine Flow Meter INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 www.hedland.com TABLE

More information

NC State University Design and Construction Guidelines Division 23 Energy Management

NC State University Design and Construction Guidelines Division 23 Energy Management 1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have

More information

Electronic Control Valves

Electronic Control Valves 131 Series (Full Internal Port) 631 Series (Reduced Internal Port) MODEL Electronic Control Valves Model 131-01/631-01 Simple Proven Design Quality Solenoid Pilot Controls Ideal For SCADA Systems Multi-Function

More information

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online... Multivariable Mass Vortex Flow Meter Features Volumetric or mass flow monitoring of gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Ideal for steam applications

More information

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C

More information

TURBINE FLOW METER SELECTION GUIDE

TURBINE FLOW METER SELECTION GUIDE TURBINE FLOW METER SELECTION GUIDE I. MODEL NUMBERING SYSTEM Format: F(B)-XX YY SERIES F-11 Single Turbine, Insertion Type (1¼" and larger pipes) F-12 Dual Turbine Insertion Type (2½" and larger pipes)

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

OPTIMASS 2000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics

More information

Spiraflo Steam flowmeters

Spiraflo Steam flowmeters Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

VERIS FLOW MEASUREMENT GROUP

VERIS FLOW MEASUREMENT GROUP 1 VERIS FLOW MEASUREMENT GROUP Flow Meter Considerations 1. Pipe Size 2. Media Being Measured 3. Flow Rates 4. Pressure 5. Temperature 6. Outputs? 2 3 Flowmeter Sizing 4 Application Data Sheets How Verabar

More information

Experiment No.3: Flow through orifice meter. Background and Theory

Experiment No.3: Flow through orifice meter. Background and Theory Experiment No.3: Flow through orifice meter Background and Theory Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters (Head flow meters)

More information

Model 8800C Vortex Installation Effects English Rev. CA

Model 8800C Vortex Installation Effects English Rev. CA Model 8800C Vortex Installation Effects 00816-0100-3250 English Rev. CA Model 8800C Vortex Installation Effects MODEL 8800C VORTEX INSTALLATION EFFECTS One of the perceived limitations of vortex meters

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters Product Specifications Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters PSS 3-5A1 E MODEL CO WITH TRADITIONAL STRUCTURE MODEL CO WITH LOW PROFILE STRUCTURE (LP1) MODEL CO

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-

More information

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Product Data Sheet PS-001041, Rev. F February 2010 Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Micro Motion ELITE High Capacity Coriolis meters offer unparalleled flow and density

More information

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual COMPANY Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:SANITARYMAN16 Mechanical Specifications Measuring Accuracy ± 1.0%

More information

DY-LWGY Liquid turbine flow meter

DY-LWGY Liquid turbine flow meter Typical Application: liquid with no impurities and no corrosion, such as water, diesel, methanol. DY-LWGY Liquid turbine flow meter One. Overview DY-LWGY series Turbine Flow has its simple structure, light

More information

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Insertion turbine INSTRUCTION SHEET.   TECHNICAL PRODUCT TECHNICAL PRODUCT INSTRUCTION SHEET Insertion turbine OVERVIEW These insertion flow transducers provide a cost effective and simple means of measuring the flow of a wide range of low viscosity liquids.

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements meters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allow for easy installation Minimize permanent pressure

More information

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together

More information

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density

More information

TX 115/215 Hot-tap Insertion Turbine Instructions

TX 115/215 Hot-tap Insertion Turbine Instructions TX 115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics THORNTON Leading Pure Water Analytics Sanitary Sensors Sanitary Sensors Temperature Sensors 3A Sanitary Turbine Flow Sensors Pressure Sensors Tank Level Sensors High Quality, Precision Sanitary Sensors

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits. GE Measurement & Control Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically for custody

More information

Rosemount 8800 Vortex Installation Effects

Rosemount 8800 Vortex Installation Effects Technical Data Sheet Rosemount 8800 Rosemount 8800 Vortex Installation Effects One of the perceived limitations of vortex meters is that they are highly sensitive to installation effects. Since it is true

More information

RCM. Direct Reading Flowmeter. for Liquids or Gases

RCM. Direct Reading Flowmeter. for Liquids or Gases Direct Reading Flowmeter for Liquids or Gases measuring monitoring analyzing RCM Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas)

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information