In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings

Size: px
Start display at page:

Download "In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings"

Transcription

1 In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings Date: Job Name: Contractor: Contractor or Order No.: Engineer: Agent: Agent P.O. No.: Date Ordered: Date Required: Walter Meier (Climate USA) Inc. 826 Proctor Ave., Odgensburg, NY Tel: nortec@waltermeier.com Walter Meier (Climate Canada) Ltd Fenton Road, Ottawa, Ontario K1T3T7 Tel: Fax: NORTEC B l 04 OCT 2011

2 Airflow Nozzle Manifolds Valve Controller Stainless steel duct liner 0-10V Signal Humidistat or BMS Air Proving Switch High Limit Humidistat 24 VAC Safety Loop Drain Pan Drains Mist Eliminator or Cooling Coil Bottom of duct To be sloped towards drain Valve Block Assembly Drain 2 (5.1 cm) taller than static pressure Water Inlet 3/4 NPT Pump module mounted remotely. Ensure high pressure line length is kept as short as possible. Max Inlet Pressure: 60 psig (Stainless steel pumps) 90 psig (Brass pumps) Use ½ stainless steel high pressure piping. 3 feet of high pressure flexible hose is recommended at the pump outlet and valve block inlet to minimize vibrations. 1/2 NPT High-Pressure Outlet Drain 1/4 NPT Power Inlet HP HVAC Typical Installation July 21,

3 Airflow Nozzle Manifolds Valve Controller Stainless steel duct liner 0-10V Signal Humidistat or BMS Air Proving Switch High Limit Humidistat 24 VAC Safety Loop Drain Pan Drains Mist Eliminator or Cooling Coil Bottom of duct To be sloped towards drain Valve Block Assembly Drain 2 (5.1 cm) taller than static pressure Pump module mounted remotely. Ensure high pressure line length is kept as short as possible. Max Inlet Pressure: 60 psig (Stainless steel pumps) 90 psig (Brass pumps) Use ½ stainless steel high pressure piping. 3 feet of high pressure flexible hose is recommended at the pump outlet and valve block inlet to minimize vibrations. Power Inlet Water Inlet 3/4 NPT Drain 1/4 NPT 1/2 NPT High-Pressure Outlet HP HVAC Typical Installation July 21,

4 Oil lubricated, triplex ceramic plunger pump no Variable Frequency Drive Model Pump Frame Volts Phase Hz Amps KW Max. Circ. Protection G500PM Medium G500PM Medium G500PM Medium G500PM Medium G500PM Medium G850PM Medium G850PM Medium G850PM Medium G850PM Medium G850PM Medium G1100PM Medium G1100PM Medium G1100PM Medium G1100PM Medium G1550PM Medium G1550PM Medium G1550PM Medium G1550PM Medium G2300PM Medium G2300PM Medium G2300PM Medium G3500PM Large G3500PM Large G5450PM Large G5450PM Large G5450PM Large Oil lubricated, triplex ceramic plunger pump with Variable Frequency Drive GVFD950PM Large GVFD950PM Large GVFD950PM Large GVFD1650PM Large GVFD1650PM Large GVFD1650PM Large GVFD2100PM Large GVFD2100PM Large GVFD2100PM Large GVFD3500PM Large GVFD3500PM Large GVFD3500PM Large GVFD6500PM Large GVFD6500PM Large GVFD6500PM Large Water lubricated, stainless steel pump with no Variable Frequency Drive D500PM Medium D500PM Medium D500PM Medium D500PM Medium D500PM Medium D500PM Medium D1100PM Medium D1100PM Medium D1100PM Medium D1100PM Medium D1100PM Medium D1100PM Medium D1800PM Medium D1800PM Medium D1800PM Medium D1800PM Medium D1800PM Medium D2900PM Large D2900PM Large D2900PM Large D2900PM Large D3650PM Large D3650PM Large D3650PM Large D3650PM Large Water lubricated, stainless steel pump with Variable Frequency Drive DVFD500PM Large DVFD500PM 460-3* Medium DVFD500PM 380-3* Medium DVFD500PM Large DVFD1100PM Large DVFD1100PM 460-3* Medium DVFD1100PM 380-3* Medium DVFD1100PM Large DVFD1800PM Large DVFD1800PM 460-3* Medium DVFD1800PM 380-3* Medium DVFD1800PM Large DVFD2900PM Large DVFD2900PM 460-3* Large DVFD2900PM 380-3* Large DVFD2900PM Large DVFD3650PM Large DVFD3650PM 460-3* Large DVFD3650PM 380-3* Large DVFD3650PM Large *Requires DVDF Programming Kit. (One kit is interchangeable for multiple pumps) Pump Modules - 4 -

5 Water Inlet 3/4 NPT (f) Optional Cover on Large Pumps (109.7 cm) Detail View Drain 1/4 NPT (m) HP Outlet 1/2 NPT (m) (132.8 cm) This pump can either be a stainless steel pump (as shown) or a triplex ceramic plunger pump (64.5 cm) Motor shown here is equipped with an optional variable frequency drive. HP HVAC - Large Pump Module Dimensional Drawing August 8,

6 16.64 (42.3 cm) Standard Cover on Medium Pumps (107.3 cm) HP Outlet 1/2 NPT (m) Drain 1/4 NPT (m) Water Inlet 3/4 NPT (f) (36.8 cm) This pump can either be a stainless steel pump (as shown) or a triplex ceramic plunger pump. Motor shown here is equipped with an optional variable frequency drive. HP HVAC - Medium Pump Module Dimension Drawing August 8,

7 Valve Controller for HP HVAC Nozzle Applications (30.1 cm) 8.00 (20.3 cm) 0.78 (2.0 cm) 1.00 (2.5 cm) Ø0.25 (0.635 cm) 9.87 (25.1 cm) (30.1 cm) Key Lock On/Off Power Knock outs for Control / Power Wiring 3 Status Iights indicate Active valves. Voltage: 120V/1ph/60Hz Full load current: 2.7 A Weight: 15 lbs (6.8 kg) HP HVAC - Valve Controller 1 Stage - Part Stage - Part Stage - Part April 9,

8 Valve Block Installation for HP HVAC Nozzle Applications The NORTEC Valve block can be installed either inside the of duct or outside of the duct. It features between one, two, or three, 3-way valves, and a flush valve. All connections to the block are compression type, and are clearly labeled on the valve block. Refer to the installation drawings provided with each system to determine which manifolds should be connected to each valve. Connections: Inlet: ½ O.D. compression Drain: ½ O.D. compression Valves: 3/8 O.D. Compression Nortec HP HVAC Valve Installation Rev. A October 7,

9 1 Stage Valve Assembly for HP HVAC Nozzle Systems 6.6 in. ( 168 mm ) 4.5 in. ( 114 mm ) 3.6 in. ( 92 mm ) 6.8 in. ( 171 mm) 8.0 in. ( 203 mm ) 8.4 in. ( 214 mm ) 2.6 in. ( 66 mm ) 3/8" Compression 1.4 in. ( 34 mm ) 4.0 in. ( 102 mm ) 2.5 in. ( 63 mm ) 1/2" Compression 8.0 in. ( 203 mm ) Voltage: 24VDC Power: 18 W per coil, 3 coils total Inlet Connection: ½ compression fitting Drain Connection: ½ compression fitting Manifold Connection: 3/8 compression fitting Max. Pressure: 2000 psig (138 bar) Min. Flow: 0.3 gpm (1 Lpm) Max. Flow: 7.9 gpm (30 Lpm) Pressure Loss: 36 max flow (2.5 bar) Weight: 16 lbs (7 kg) Material: 304 stainless steel and plastic Nortec HP HVAC 1 Stage Valve Assembly Rev. A April 12,

10 3 Stage Valve Assembly for HP HVAC Nozzle Systems 6.6 in. ( 168 mm ) 4.5 in. ( 114 mm ) 3.0 in. ( 75 mm ) 1.5 in. ( 39 mm ) 1/2" Compression O 0.4 in. ( 10 mm ) 4.1 in. ( 105 mm ) 2.1 in. ( 55 mm ) 6.8 in. ( 171 mm ) 3.6 in. ( 92 mm ) 2.3 in. ( 57 mm ) 3/8" Compression 8.4 in. ( 214 mm ) 6.0 in. ( 152 mm ) 4.0 in. ( 100 mm ) 1.4 in. ( 34 mm ) 3.2 in. 2.3 in. ( 80 mm ) ( 57 mm ) 1.5 in. ( 39 mm ) 6.0 in. ( 152 mm ) 2.6 in. ( 66 mm ) 8.0 in. ( 203 mm ) Voltage: 24VDC Power: 18 W per coil, 5 coils total Inlet Connection: ½ compression fitting Drain Connection: ½ compression fitting Manifold Connection: 3/8 compression fitting Max. Pressure: 2000 psig (138 bar) Min. Flow: 0.3 gpm (1 Lpm) Max. Flow: 7.9 gpm (30 Lpm) Pressure Loss: 36 max flow (2.5 bar) Weight: 28 lbs (13 kg) Material: 304 stainless steel and plastic Nortec HP HVAC 3 Stage Valve Assembly Rev. B April 12,

11 6 Stage Valve Assembly for HP HVAC Nozzle Systems 6.6 in. ( 168 mm ) 4.5 in. ( 114 mm ) 3.0 in. ( 75 mm ) 1.5 in. ( 39 mm ) O 0.4 in. ( 10 mm ) 1/2" Compression 4.9 in. ( 123 mm ) 2.9 in. ( 74 mm ) 3.6 in. ( 92 mm ) 6.8 in. ( 171 mm) 0.9 in. ( 24 mm ) 2.3 in. ( 57 mm ) 3/8" Compression 8.4 in. ( 214 mm ) 6.0 in. ( 152 mm ) 4.0 in. ( 100 mm ) 3.2 in. ( 80 mm ) 1.4 in. ( 34 mm ) 2.3 in. ( 57 mm ) 2.6 in. ( 66 mm ) 1.5 in. ( 39 mm ) Voltage: 24VDC Power: 18 W per coil, 7 coils total Inlet Connection: ½ compression fitting Drain Connection: ½ compression fitting Manifold Connection: 3/8 compression fitting Max. Pressure: 2000 psig (138 bar) Min. Flow: 0.3 gpm (1 Lpm) Max. Flow: 7.9 gpm (30 Lpm) Pressure Loss: 36 max flow (2.5 bar) Weight: 38 lbs (17kg) Material: 304 stainless steel and plastic 8.0 in. ( 202 mm ) 8.0 in. ( 203 mm ) Nortec HP HVAC 6 Stage Valve Assembly Rev. B April 12,

12 3 STAGES Drain High-Pressure Water Inlet 6 STAGES Drain High-Pressure Water Inlet * For 1 Stage Systems (On/Off) connect all manifolds together (not shown). Nortec HP HVAC 3 Stage & 6 Stage Nozzle Manifolds September 18,

13 Vibration Clamp for HP HVAC Nozzle Applications 3/8" OD 1.1 in. ( 28 mm ) 1.4 in. ( 34 mm ) 1.2 in. ( 30 mm ) Nortec HP HVAC Vibration Clamp Rev. A April 9,

14 Mounting Rail Kit for HP HVAC Nozzle Applications Mounting Rail QTY: in. ( 11 mm ) 1.2 in. ( 31 mm ) 1.1 in. ( 29 mm ) 2.5 in. ( 64 mm ) 0.2 in. ( 6 mm ) 96.0 in. ( 2438 mm ) Mounting Rail Gusset QTY: in. ( 154 mm ) 1.2 in. ( 31 mm ) D 3.1 in. ( 78 mm ) 0.3 in. ( 8 mm ) D 0.3 in. ( 8 mm ) Note: Kit also includes 4x (1/4 Bolt) and 4x (1/4 Locknut) Nortec HP HVAC Mounting Rail Kit Rev. A April 9,

15 Mounting Rail Installation for HP HVAC Nozzle Applications Nortec HP HVAC Mounting Rail Installation Rev. A April 9,

16 Mounting Rail Extension Kit Kit Includes: 1x HP Mounting Rail 4x Bolt, 1/4-20 UNC x x Lock Nut, 1/4-20 UNC Material Specifications: Rail: 304 Stainless steel, 16 gauge HP Mounting Rail Extension Kit Rev. A May 3,

17 Nortec HP HVAC Nozzle Specification Data Sheet Nortec HP HVAC nozzles are impeller-type nozzles and produce a very fine mist without the use of impingement pins or compressed air. Water at 1000psig is sprayed though a (0.20 mm) or 0.005" (0.13 mm) orifice producing droplets between 10 and 40 microns in size, with 95% of the droplets at 15 microns. The nozzle and impeller are constructed from 316 stainless steel for long life. A raised impeller insert helps shed water after the nozzle has stopped fogging, which will reduce possible nozzle blockage. A Viton o-ring is used to create a leak free seal, and allows nozzles to be installed or removed without tools. To prevent dripping after the system has shut down, the nozzles are screwed into anti-drip check valves. The nozzles are made in the USA to tolerances of ( mm), and tested for quality prior to shipping. Proper Spray Pattern Nozzle Anti-Drip Assembly 2" (5.1 cm) NOZZLE ANTI-DRIP SPRING ANTI-DRIP BODY O-RING ANTI-DRIP CHECK BALL O-RING 2" (5.1 cm) Specifications Insert Length: (4.95 mm mm) Insert Diameter: (4.78 mm mm) Wall Thickness: (2.22 mm mm) Thread Pitch 12/24 NC Flow Rate.008 (0.020 cm) orifice.025 GPM (0.45 Lpm) or 12 lbs/hr (5.4 kg/hr) at 1000 PSI (68.9 Bar).005 (0.013 cm) orifice.015 GPM (0.57 Lpm) or 5 lbs/hr (2.3 kg/hr) at 1000 PSI (68.9 Bar) Part Numbers , HP HVAC Nozzle April 12,

18 Mist Eliminator for HP HVAC Nozzle Applications The NORTEC Mist Eliminator is a single bank droplet removal system, designed to capture water within its media. Entrained water is either evaporated by the passing airflow, increasing water efficiency, or flows down towards the drain pan at the bottom of the duct section. The Mist Eliminator is commonly installed at a slight upstream angle (10-30 ). When installed in this way, the top of the Mist Eliminator is farther upstream than the bottom, and airflow drives the water downwards to the drains. For duct sizes in between the standard sizes, the next largest Mist Eliminator is ordered and trimmed to fit during installation. Media Specifications: Color: White Coatings: Antimicrobial UV: Compatible with UV duct sterilization Thickness: 1 nominal Initial Resistance: 300 fpm Basis Weight: 1 oz. per square foot UL Rating: Class 2 Size (ft) Part Number Width Height Pressure Drop Across Wet Mist Eliminator (in. H 2O) Air Velocity (FPM) HP HVAC Mist Eliminator September 18,

19 HP HVAC Mist Eliminator - Typical Installation January 2, 2008

20 L1 L2 L3 Contactor L3 L2 L1 Overload Relay T3 T2 T1 L3 L2 L1 MOTOR 24VAC Contactor Primary Line Voltage 24vac 3 Amps 24vac COM. Connected to Cabinet GND G Humid ON Indicator Lamp Off/Auto/Manual SW Water Pressure Switch Manual COM W NO NC R Bk Push to reset hour counter AUTO Warm Water Relief Valve Thermostatic Sensor G Humid Active Indicator Lamp L1 N I1 I2 I3 I4 I5 I6 (Make connection to force shutdown 100 hours after maintenance warning) R Humid Fault Indicator Lamp Q1 Q2 Q3 Q4 24 VAC Cooling Fan for Totally Enclose Model only Y Humid Service Indicator Lamp Humid ON Relay Humid Active Relay Humid Service Relay Humid Fault Relay Manifold Control Connection Humid ON Humid Active N/O Humid Service COM N/C Humid Fault Pump Control WD Rev. F 08/19/

21 L1 L2 L3 3 Amp s s s 1 Amp 1 Amp Primary Line Voltage 24vac 24vac COM. Connected to Cabinet GND G Contactor L3 L3 V L2 L1 24VAC Contactor Humid ON Indicator Lamp Off/Auto/Manual SW Manual Overload Relay T3 T2 T Water Pressure Switch COM NO NC R W Bk + - Pressure Transmitter (4-20 ma) Variable Speed Controller L2 W L1 U Analog input (0-20mA) 60 [ VLT 2800 only ] Analog input (0-20mA) [ VLT FC 200 only ] Com. Analog output Com. Analog input Star/Stop Digital input (other) 24 vdc Supply VDC VDC Supply Push to reset hour counter L3 L2 L1 MOTOR AUTO L1 N I1 I2 I3 I4 I5 I6 Warm Water Relief Valve Thermostatic Sensor G Humid Active Indicator Lamp R Humid Fault Indicator Lamp Q1 Q2 Q3 Q4 24 VAC Cooling Fan for Totally Enclose Model only Y Humid Service Indicator Lamp Humid ON Relay Humid Active Relay Humid Service Relay Humid Fault Relay Manifold Control Connection Humid ON Humid Active Humid Service N/O COM N/C Humid Fault Pump Controller with Danfoss VLT 2800 or VLT Aqua FC 200 WD Rev. G 03/07/11

22 L1 L2 L3 Contactor Overload Relay Variable Speed Controller L3 T3 L3 T3 L3 L2 L1 T2 T1 L2 L1 T2 T1 L2 L1 MOTOR Primary Line Voltage 24vac 3 Amp s 24vac COM. Connected to Cabinet GND G 24VAC Contactor Humid ON Indicator Lamp Off/Auto/Manual SW Water Pressure Switch 1 Pressure Transmitter 2 + (4-20 ma) - X101 1 Analog input (0-20mA) 2 Analog input (0-10 V) 3 Digital input 4 Star/Stop 5 Digital iput (other) 6 24 vdc Supply 10 vdc Supply V for terminals 1-7 and 9 Analog (0-20 ma) output Manual COM W NO NC R Bk Push to reset hour counter AUTO Warm Water Relief Valve Thermostatic Sensor G Humid Active Indicator Lamp L1 N I1 I2 I3 I4 I5 I6 (Make connection to force shutdown 100 hours after maintenance warning) R Humid Fault Indicator Lamp Q1 Q2 Q3 Q4 24 VAC Cooling Fan for Totally Enclose Model only Y Humid Service Indicator Lamp Humid ON Relay Humid Active Relay Humid Service Relay Humid Fault Relay Manifold Control Connection Humid ON Humid Active N/O Humid Service COM N/C Humid Fault Pump Controller with Danfoss Integrated VFD WD Rev. D August 19,

23 L+ M I-1 I-2 I-3 I-4 I-6 I-7 I-8 I-5 PLC UNIT #1 Q1 Q2 Q3 Q4 2/6 1/3 ON/OFF Power Switch 2/5 1/2 _ V + V 24Vdc output Power On Green 24 V Valve # 1 On Yellow 24 V 24Vdc Power Supply N L N L Input Voltage 120Vac 60Hz 2.7A INTERNAL EXTERNAL ON/OFF LOOP 24 Vdc _ Vdc * V1 N/C + + V1 N/O Pump Control + FLUSH INTERNAL EXTERNAL * For time proportioning control, connect 0-10 Vdc humidistat. For on/off control, jumper between 1 and 4 and put humidistat on 1 and 2 ON/OFF loop NOTE: Valve Voltage: 24 Vdc Valve Power Consumption: 18 W each 1 Stage Valve Controller WD Rev. D June 25,

24 L+ M I-1 I-2 I-3 I-4 I-5 I-6 I-7 I-8 L+ M I-1 I-2 I-3 I-4 I-5 I-6 I-7 I-8 PLC UNIT #1 PLC UNIT #2 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 2/6 1/3 2/5 1/2 ON/OFF Power Switch Power On Green 24 V Valve # 1 On Yellow 24 V _ V + V 24Vdc output 24Vdc Power Supply Valve # 2 On Yellow 24 V N L N L Input Voltage 120Vac 60Hz 2.7A INTERNAL EXTERNAL ON/OFF LOOP 24 Vdc Vdc V1 N/C V1 N/O - - V2 N/C V2 N/O Pump Control + - FLUSH INTERNAL EXTERNAL Valve #1 Valve #2 Valve #3 Valve #4 Valve #5 NOTE: Valve Voltage: 24 Vdc Valve Power Consumption: 18 W each 3 Stage Valve Controller Wiring Diagram No REV. D June 25,

25 L+ M I-1 I-2 I-3 I-4 I-5 I-6 I-7 I-8 L+ M I-1 I-2 I-3 I-4 I-5 I-6 I-7 I-8 PLC UNIT #1 PLC UNIT #2 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 2/6 1/3 2/5 1/2 ON/OFF Power Switch Power On Green 24 V Valve # 1 On Yellow 24 V _ V + V 24Vdc output 24Vdc Power Supply N L Valve # 2 On Yellow 24 V Valve # 3 On Yellow 24 V N L Input Voltage 120Vac 60Hz 2.7A INTERNAL EXTERNAL ON/OFF LOOP 24 Vdc Vdc V1 N/C V1 V2 V2 V3 V3 N/O N/C N/O N/C N/O FLUSH Pump Control INTERNAL EXTERNAL NOTE: Valve Voltage: 24 Vdc Valve Power Consumption: 18 W each 6 Stage Valve Controller Wiring Diagram No REV. C June 25,

Steam Distributor Submittal Drawings

Steam Distributor Submittal Drawings Steam istributor Submittal rawings ate: Job Name: Contractor: Contractor or Order No.: Engineer: Agent: Agent P.O. No.: ate Ordered: ate Required: Walter Meier (Climate USA) Inc. 826 Proctor Ave., Odgensburg,

More information

HP Series. Installation and Operation Manual

HP Series. Installation and Operation Manual Important: Read and save these instructions. This guide to be left with equipment owner. HP Series Installation and Operation Manual Includes installation, operation maintenance and troubleshooting information

More information

2016 PRODUCT CATALOG. Fogco Systems, Inc Fogco.com FOGCO

2016 PRODUCT CATALOG. Fogco Systems, Inc Fogco.com FOGCO 2016 PRODUCT CATALOG 1 2016 PRODUCT CATALOG SYSTEMS, INC. Fogco provides integrated solutions for commercial and industrial climate control projects. Applications include humidification, dust/odor control,

More information

Oil Streak Air-Oil Generating Unit

Oil Streak Air-Oil Generating Unit Oil Streak Air-Oil Generating Unit GENERAL The Air-Oil Generating system delivers high efficiency lubrication for high-speed spindles and other applications requiring accurate oil deliveries, in combination

More information

Fog Misting System. Misting systems have been used in outdoor cooling applications for decades. These systems can provide outdoor cooling

Fog Misting System. Misting systems have been used in outdoor cooling applications for decades. These systems can provide outdoor cooling Aquashi have teamed up with Fogco USA to provide you with one of the best mist and fog systems available in the market today. Fogco is a manufacturer of high pressure mist and fog systems for industrial,

More information

Nessie Water Mist Nozzles

Nessie Water Mist Nozzles Data Sheet Nessie Water Mist Nozzles Applications The nozzles are tailored to atomize water in high pressure water mist systems. The nozzles are very suitable for applications within e.g.: Humidification

More information

STEAM INJECTION HUMIDIFIER LIVESTEAM. Submittal Drawings

STEAM INJECTION HUMIDIFIER LIVESTEAM. Submittal Drawings STEAM INJETION HUMIDIFIER LIVESTEAM Submittal Drawings Date: Job Name: ontractor: ontractor or Order No.: Engineer: Agent: Agent P.O. No.: Date Ordered: Date Required: U.S.A. 2207 90th St., Sturtevant,

More information

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

VSO - MI thermally compensated proportional valve

VSO - MI thermally compensated proportional valve The VSO - MI is a miniature proportional valve specifically designed for medical device manufacturers and incorporates thermal compensation to provide precise flow control and stability over a wide operating

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

Nortec EL SPARE PARTS LIST. Contents. IMPORTANT! This document to be left with the equipment.

Nortec EL SPARE PARTS LIST. Contents. IMPORTANT! This document to be left with the equipment. 2582959_C_EN_608 Nortec EL SPARE PARTS LIST Proprietary Notice This document and the information disclosed herein are proprietary data of Nortec Humidity Ltd. Neither this document nor the information

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN Operating manual LPS Humidifies and Cools ÁLPS.ENzÈ LPS.EN 4.2.4 Atomising nozzles Desalinated water at a pressure of up to 16 bar reaches the nozzles where the water is atomised to form ultra-fine mist-like

More information

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG Q UA L I T Y VA LV E S A N D C O N T R O L S. TO D AY A N D TO M O R R O W. Texas Industrial Remcor, Inc. CATALOG NO. 33 The new RC2 control system: Ensures no potential leaks in the tractor cab when using

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS Ogdensburg, New York, U.S.A. 1-866-NORTEC-1 Ottawa, Ontario, Canada 1-866-NORTEC-1 ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS The LS Series is a cost effective way to provide precise humidity control,

More information

QUALITY MISTING PUMPS

QUALITY MISTING PUMPS DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

MODEL 10LH SPECIFICATION

MODEL 10LH SPECIFICATION MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard)

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783 Model Number:

More information

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE EM101 LOW FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101 LOW-FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101-025 EM 101-038 EM 101-050 GENERAL INFORMATION The EM101 is a small plastic-bodied electromagnetic

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology Technical Bulletin TB-ACV-LFF11RFP_SentryPlus LEAD FREE * LFF11RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology Installed upstream of Reduced Zone Backflow Preventer.

More information

Hamilton 3VO Submittal

Hamilton 3VO Submittal Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM Complete Product Line A cost-effective solution for extending the life of batteries and reducing lift truck electrical problems

More information

Pneumatic atomizing nozzles ViscoMist flat fan, external mix Series 176

Pneumatic atomizing nozzles ViscoMist flat fan, external mix Series 176 nozzles ViscoMist flat fan, external mix Versatile design with builtin pneumatic needle valve for liquid flow control and automatic clean-out. Three nozzle body configurations offer flexible tailoring

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS TECHNICAL BROCHURE BSPDDRIVE C U L US Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS Aquavar SPD variable speed, constant pressure pump controller

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP ES--LFFFP Job Name Contractor Job Location Approval Engineer Contractor s P.O. No. Approval Representative LEAD FREE * LFFFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

More information

70.03 Victaulic Vortex TM

70.03 Victaulic Vortex TM Series 951 Combination Box with Ball Valve Series 951 Combination Box with Solenoid Patent 7,686,093 - Dual Extinguishment fire suppression system using high velocity low pressure emitters. oreign patents

More information

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual Mechanical Specifications Flow Meter with Polypropylene Body (ES version) Maximum Operating Pressure: 150 PSIG Maximum

More information

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER FH Series The FH-series line of fire hose testers, offers testing pressures up to 1,000 PSI, with flow rates up to 10 GPM. Gas, Electric, and Diesel driven models, designed to safely test fire hose up

More information

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Users Manual Certified Series Direct Drive Pump 1-7 LPM Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com

More information

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL 60100-HDE-1PH-230VFD SAFETY, GENERAL INFORMATION, ELECTRICAL DEFINITIONS WARNING CAN cause DEATH, SEVERE INJURY or substantial property damage.

More information

Submittal. Front View Side View

Submittal. Front View Side View RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION Packaged Pump Sets for Diesel/Fuel Oil Application Page 2 Description Simplex SPS Series Packaged

More information

Increase Turbine Output. Gas Turbine Inlet Cooling

Increase Turbine Output. Gas Turbine Inlet Cooling Increase Turbine Output Gas Turbine Inlet Cooling AMCO GAS TURBINE DIRECT SPRAY INLET COOLING AMCO provides extensive engineering, manufacturing, and application knowledge of Inlet direct spray cooling

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:PADDLEMAN082416 Mechanical Specifications Flow Meter with Polypropylene

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

ACTIVE CHILLED BEAM 6 1/4" HEATING 9 1/2" DISCHARGE DIRECTION. 1 7/8" u 1/4" NOZZLE SIZE:

ACTIVE CHILLED BEAM 6 1/4 HEATING 9 1/2 DISCHARGE DIRECTION. 1 7/8 u 1/4 NOZZLE SIZE: LINEAR 24" WIDE Submittal Sheet WATER COIL CONNECTIONS 9 1/2" 6 1/4" HEATING 9 3/8" COOLING PRIMARY AIR CONNECTION DISCHARGE DIRECTION 17 1/16" FACE WIDTH 23 3/4" 2-WAY SHOWN DISCHARGE DIRECTION MOUNTING

More information

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve NEOTHERM Hydronic Boiler NTH Hydronic Boiler Date: Indoor Sizes 285-850 Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Large LCD display

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV BLADE MASTER AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV.020112 "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS The "Blade Master is a high-volume, low-energy, (U.L. /C.S.A.,

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

TotalPac 3 Deluge, Electric release Remote controlled system

TotalPac 3 Deluge, Electric release Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Non interlock Preaction system Pneumatic release (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

QUALITY MISTING PUMPS

QUALITY MISTING PUMPS TOTALLY ENCLOSED DIRECT DRIVE 60030KH, 60031KH, 60050KH, 60051KH 60100KH, 60101KH, 60150KH, 60151KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION,

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS OV300E MINI RACK OVEN ML-132155 OV300E A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43051 Rev. C (July 2017) F-43051 Rev. C (July 2017)

More information

THE JOB PRO PARTS LIST FOR JP-1002/1502-0ME1. Motor Horsepower: Nozzle Size: Copyright 2003, Mi-T-M Corporation

THE JOB PRO PARTS LIST FOR JP-1002/1502-0ME1. Motor Horsepower: Nozzle Size: Copyright 2003, Mi-T-M Corporation THE JOB PRO PARTS LIST FOR JP-1002/1502-0ME1 Motor Horsepower: jp-1002-0me1: jp-1502-0me1: Pump Oil Grade: Pump Oil Capacity: Nozzle Size: jp-1002-0me1: jp-1502-0me1: 1.5 H.P. 2.0 H.P. Mi-T-M Pump Oil

More information

Miniature Proportional Valve. Non-Thermally Compensated Proportional Valve

Miniature Proportional Valve. Non-Thermally Compensated Proportional Valve MD PRO Miniature Proportional Valve Non-Thermally Compensated Proportional Valve Typical Applications O 2 Concentrators/Conservers Ventilators Anaesthesia Delivery Pressure & Control Patient Monitors The

More information

PSF50 Paddle flow switch

PSF50 Paddle flow switch Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up

More information

AD-830. Parts Manual thru 1997

AD-830. Parts Manual thru 1997 AD-830 Parts Manual 1995 thru 1997 American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9010 / Fax: (508) 678-9447 E-mail address: service@amdry.com 072696 092497DX/abe

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER FH Series The FH-series line of fire hose testers, offers testing pressures up to 1,000 PSI, with flow rates up to 10 GPM. Gas, Electric, and Diesel driven models, designed to safely test fire hose up

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Electrical Components

Electrical Components Table of Contents ELECTRICAL COMPONENTS Electrical Components 3 ELECTRICAL COMPONENTS 1 Electrical Cables.... 3-1 - 3-2 Hitch Ball & Grounding Jumpers.... 3-3 Fuses... 3-4 - 3-6 Fuse Packages... 3-7 Cord

More information

New Fan Coil Piping Packages

New Fan Coil Piping Packages New Fan Coil Piping Packages SO BUILT TOUGH, TOUGH. WE BUILT GUARANTEE TO LAST. IT. www.superiorrex.com Piping Packages Table of Contents General Notes and Legend... 3 Piping Package Code Descriptions

More information

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-10A & FTI-20A Single Tank Installation Manual

More information

Product Instructions. Mixing Station. Features. Specifications. Materials

Product Instructions. Mixing Station. Features. Specifications. Materials Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal

More information

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) PACKAGED PUMP SYSTEM WITH CAPACITIES TO 300GPM, PRESSURE BOOST TO 100PSI* WITH UP TO 25HP ON EACH PUMP AVAILABLE IN DUPLEX, AND TRIPLEX CONFIGURATION, AND

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only GENERAL These split-system condensing units are designed to

More information

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER 30GX-5SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GX-5SB Supersedes 30GX-4SB Printed in U.S.A. 5-98 Catalog No.

More information

PARTS MANUAL CYNCRA MODEL Synesso, Inc. 309 S. Cloverdale, C41, Seattle, WA Tel: / Fax

PARTS MANUAL CYNCRA MODEL Synesso, Inc. 309 S. Cloverdale, C41, Seattle, WA Tel: / Fax PARTS MANUAL CYNCRA MODEL 2008 Synesso, Inc. 309 S. Cloverdale, C41, Seattle, WA 98108 Tel: 206.764.0600 / Fax 206.764.0601 www.synesso.com 2 TABLE OF CONTENTS Body...4-7 Hydraulic components...8-15 Electrical

More information

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG Productinformatie A.U.K. MÜLLER GMBH & CO. KG Solenoid valves Control valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)211-7391-0 Fax: +49(0)211-7391-281

More information

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units WWW.KRUEGER-HVAC.COM PIPING PACKAGES For Chilled and Hot Water Fan Coil Units PROVIDING YOU WITH AIR DISTRIBUTION AND EQUIPMENT SOLUTIONS TABLE OF CONTENTS General Notes... 4 Code Descriptions... 5 Guide

More information

DME Valve Gate Controls

DME Valve Gate Controls DME ENERGY EFFICIENT, RELIABLE AND COMPACT HYDRAULIC AND PNEUMATIC CONTROLS 30 DME Valve Gate Controller Products and Solutions DME Valve Gate Controller Products and Solutions Solid-state timers and relays

More information

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines Installation and Users Manual For the following Prelube Kits: VARNA Products P/N 6423 Kit for 208 VAC 3 Phase VARNA Products

More information

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 23 74 13 PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

VSO Thermally Compensated Proportional Valve

VSO Thermally Compensated Proportional Valve 4 VSO Thermally Compensated Proportional Valve Typical Applications Gas Chromatography Mass Spectrometry Ventilators O 2 Concentrators/Conservers Anaesthesia Delivery & Monitors Pressure & Control Mass

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS GENERAL Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 00, HB 60 / 80 / 600, HF-25, HL-0 / -0 / -50 Models These split-system condensing units

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

PIPING PACKAGES TABLE OF CONTENTS

PIPING PACKAGES TABLE OF CONTENTS PIPING PACKAGES TABLE OF CONTENTS ITEM PAGE General Notes and Legend........................................................ 3 Piping Package Code Descriptions & Diagrams VAV Products and HL, HP, VF, and

More information

Series PRV-71H Pressure Reducing Valve Operation and Maintenance Manual

Series PRV-71H Pressure Reducing Valve Operation and Maintenance Manual Series PRV-71H Pressure Reducing Valve Operation and Maintenance Manual All Hydro Instruments Chemical Feed systems are carefully designed and tested for years of safe, accurate field service. All Hydro

More information

SAM-e. Engineering Manual

SAM-e. Engineering Manual Your guide to selecting and specifying Nortec SAM-e Short Absorption Manifolds! SAM-e Engineering Manual Includes technical specifications, guidelines, and options for selection and application of SAM-e

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 00, HB 60 / 80 / 600, HF-25, HL-0 / -0 / -50 Models GENERAL These split-system condensing units

More information

NV Direct Coupled Globe Valve Actuator

NV Direct Coupled Globe Valve Actuator 70396 Rev. C Non-spring return, on/off, floating point, proportional control NV Direct Coupled Globe Valve Actuator NV24-3 US NVD24-3 US NV24-MFT US NVD24-MFT US Application For on/off, floating point

More information