EPD30 Electromagnetic Flow Meter.

Size: px
Start display at page:

Download "EPD30 Electromagnetic Flow Meter."

Transcription

1 EPD0 Electromagnetic Flow Meter

2 FLOW MEASUREMENT FIELD FineTek is the only inspection institution that owns a Class flow test laboratory in Taiwan. With the most professional R&D and Design Team, it can design and develop highaccuracy electromagnetic flow meters. Moreover, it conducts calibration in Class Flow Laboratory of the National Measurement Laboratory (ITRI Measurement Center), so as to guarantee the flow accuracy on the measurement field. FineTek s flow laboratory has received certification from the Taiwan Accreditation Foundation and conforms to the regulations of international organizations such as ILAC and APALC. It has the complete ability of uncertainty testing and rating for flow test.

3

4

5 ELECTROMAGNETIC FLOW METER EPD electromagnetic flow meter is a highaccuracy flow meter manufactured based on the latest international technology. It is widely applied in papermaking, chemical industry, metallurgical industry, drainage, waste water treatment, liquid highpressure metering, medical care, food, and environmental protection industries. It is used to measure the nonmagnetic liquid and plasma in the enclosed pipe. WORKING PRINCIPLE The working principle of the electromagnetic flow meter is based on the Faraday law of electromagnetic induction. When the conducting liquid flows in the orthogonal direction of the magnetic line direction, it will cut the magnetic lines and generate induced voltage, which shows linear relationship with the flowing speed. Thus, the fluidic volume flow can be calculated. EPD electromagnetic flow meter is mainly composed of the sensor and transmitter. The measuring tube of the sensor is equipped with the excitation coils upward and downward. The transmitter supplies the excitation current, which generates the magnetic field which goes through the measuring tube once it is powered on. A pair of induction electrodes installed on the inner side of the measuring tube comes in contact with the liquid to guide the induced voltage to the sensor. FEATURES The measurement results are not affected by the change in liquid density, viscosity, temperature, pressure and conductivity. Powersaving and low fault rate: The measuring tube is without baffle and movable parts, so it won t cause pressure loss and jam. It can be widely applied in the conducting liquids that may contain fiber, solid granules and suspended matters. It is easytoinstall with low requirements for the straight tube section (Front D and rear 5D). The wide measurement turndown ratio can reach :00, which can be set randomly and achieve high accuracy for small flow measurement. Protection rating: Integrated type DN0~DN00 (IP67/NEMA X) Highlyintegrated backlit display of two rows, dual isolation, parameter setting, menutype operation, memory function, reliable programming, password lock and access, small signal elimination, nonlinear correction and twoway measurement. Smart selfdetection and selfdiagnosis function, as well as various alarms. Various outputs: Current output ~0 ma/0~0 ma, frequency output ~khz and RS5 communication. Various options of bushing and electrode material, applicable to different media. APPLICATIONS Waste water treatment Tapped water purification Sewerage Sea water desalination module Dyeing machines Solar energy and PCB wet processing Food manufacturing Pharmaceutical machines

6 SPECIFICATION Item Display Buttons Communication interface Accuracy Medium temperature Ambient temperature Fluidic conductivity Measuring scope Current output accuracy Current output mode Analog output Maximum load of current output Alarming current Frequency output scope Pulse width Pulse mode Time constant Control output (DO) Control input (DI) Baud rate Protection rating Enclosure material Input power Power consumption Wire inlet specification Excitation mode EPD0 LCM *6 pixel backlit type Tributton operation RS5 (Modbus) (Optional support for ZigBee Pro wireless transmission) ±0.5% of optional) 0 ~ 0 BC 0 ~ 70 BC >5 us/cm 0.m/s ~ 0m/s 0.% of Pulse Output Accuracy Temperature coefficient (0ppm/BC) Proactive ~ 0mA < 700Ω.5mA or ma 0.0 ~,000 Hz Automatic (pulse width 50%) NPN transistor output vdc/00ma 0.~0 s NPN transistor output vdc/00ma ;CH Dry contact ON< 00Ω ;,000Ω< OFF ; CH 00 ~ 00 bps IP67 / NEMA X Aluminum alloy AC 00~0 Vac < 0W M0 x.5* Female Pulse DC Vibration regulation IEC 6006 EMC regulation IEC/EN 66 Class A table It can t display when LCM is lower than 0.

7 MATERIAL SELECTION Electrode material Electrode material Stainless steel (6L) Hastelloy alloy Anticorrosion property It is applied in water, sewage and organic and nonorganic corrosive medium. It is resistant to the corrosion of the medium mixture of oxidizing acid such as Nitric acid, mixed acid or Sulfuric acid. Moreover, it is resistant to the corrosion of the + + oxidizing salt such as Fe Cu or other substances containing oxidants such as the salt solution of hypochlorous acid above the ambient temperature and sea water. Titanium It is resistant to the corrosion of sea water, various oxides, salt solution of hypochlorous acid, oxidating acid (including fuming Nitric acid) and organic acid and alkane. It is not resistant to the corrosion of pure reducing acid (such as Sulfuric acid and Hydrochloric acid). However, the anticorrosion property will be greatly degraded if the acid contains some oxidants. Bushing material Bushing material PTFE Main properties. Stable chemical properties, resistant to various acid, alkane, and salt solutions and various organic solvents. It is not tolerant to the corrosion of CIF, hightemperature OF and highspeed liquid oxygen and ozone.. The antiabrasion property is average. Application scope. 0~0BC. Strong corrosive medium such as concentrated acid and alkane.

8 APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION t t H H H fd fc H fd fnqh fc L fnqh q L q DN0~0 DN00~00 Connection specification Nominal diameter(mm) Bushing material JIS 0K 0 00 PTFE Length External diameter L fd PCD fc Flange thickness t Inclined angle of screw hole q Diameter of screw hole qh Quantity of screw holes N Height of sensor casing H Total height H Weight (kg) Length External diameter PCD Connection specification Nominal diameter(mm) Flange thickness Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Bushing material Inclined angle of screw hole L fd fc t q qh N H H ANSI 50Lbs PTFE Remarks: For DN0~DN0, the bushing protective ring is mm, so the total length of the flow meter shall be increased by mm. For DN00~DN00, the bushing protective ring is 0.5mm, so the total length of the flow meter shall be increased by mm

9 PIPE DIAMETER, FLOW RANGE AND ACCURACY SELECTION Pipe diameter (mm) Flow range ( m /h) Flowing speed.0~0m/s.5~5. 7.~7.9~9.~.~.~ 6.6~66 ~0 5

10 INSTALLATION INSTRUCTIONS. The flow meter must be free from strong electromagnetic field. The magnetic intensity of the flow meter installation site must be smaller than 00A/m (It should not be installed near large motors or transformers).. It should be installed at the lower point and the vertically upward point of the horizontal pipe. Don t install it at the highest point and the vertically downward point of the pipe.. It should be installed at the rising point of the pipe.. It should be installed at the lower point of the pipe when it is installed on the pipe with opening for drainage. 5. If the pipe gap exceeds 5m, the air release valve should be installed at the downstream of the sensor. The downstream of the sensor should have some back pressure. Air Release Valve 6. The control valve and cut valve should be installed at the downstream of the sensor rather than the upstream. 7. The sensor should be installed at the pump outlet rather than the inlet.. The fluidic must flow towards the arrow direction of the flow meter. 9. The axial line of the measuring electrode must be approximate to the horizontal direction (The angle of from the horizontal direction). 0. The measuring pipe must be completely filled with liquid. 6

11 . The straight tube section is required to be at least 5D (internal diameter of the flow meter) on the front side, and at least D on the rear side.. When measuring the mixture of different media, the distance between the mixing point and the flow meter must be 0D at least.. For convenient cleaning and maintenance of the flow meter, a bypass pipe must be installed.. When installing the sensor, it should ensure that the measuring pipe and the process pipe must be on the same axial line. For the flow meter with the pipe meter of 50mm or below, the axial line deviation should not exceed mm. For those of DN65~DN50, the axial line deviation should not exceed mm. For those of DN00, the axial line deviation should not exceed mm. 5. The shim installed between the flanges should have excellent anticorrosion property. The shim should not intrude in the pipe, which will affect the fluidic in the pipe. 6. The sensor and transmitter should be equipped with highquality independent grounding wire (The section area of the copper core is.6mm). The grounding resistance should be <0Ω. If the grounding is poor, it won t work normally. The grounding ring is needed if the pipe connecting with the sensor is insulating, and the material of the grounding ring should be the same as that of the electrode. If the test medium is abrasive, the neck grounding ring should be selected. 6. It is for installing the flow meter on the metal pipe not coated with insulating layer internally. 6. When installing the flow meter on the protective pipe of the cathode, the pipe with the protection of electrolytic corrosion generally has insulating walls and protruding sides. Thus, during installation, the grounding ring and the flanges on the pipe should be insulating. 6. When installing the flow mater on the plastic pipe or the pipe with insulating coating material, paints or bushing, grounding rings on both ends of the sensor should be installed. 7

12 ORDERING INFORMATION EPD0 5 E L N J F 0 Pipe Diameter 00: 0mm 050: 50mm 065: 65mm 00: 0mm 00: 00mm 50: 50mm 00: 00mm Connection Specification M: 5kg/cm V: 7.5Kg/ cm N:0Kg/cm F:6Kg/cm G:0Kg/cm O: 50Lbs P:00Lbs H:600Lbs S:Special Casing and Flange Material 5: Carbon Steel W: PN0 X : PN6 Y : PN5 Z : PN0 Bushing Material E: PTFE Electrode Material L: SUS6L H: Hastelloy alloy C76 T: Titanium Electrode Type N: Normal Type Power Supply and Signal Transmission J: Integrated Flow Meter, 00~0 Vac 50/60Hz, 0mA, pulse output, RS5 Accuracy A: 0.% F: 0.5% G:.0% Grounding Ring : None 0: SUS 0 L: SUS6L H: Hastelloy alloy C76 T: Titanium

13 SETTING VALUES Easy Setting No. Parameter Option Unit 備註 Default ValueRemarks Device Tag Num none 0000 Zero adjustment m/s actual Flow Span Permitted maximum value Flow Rate Unit Liter 5 Low flow Cutoff % Damping Time Pulse Output Unit Total reset Second Unit/pulse 0.0L Cancel Basic Setting Parameter Option No. Unit Default ValueRemarks Device Tag Num none 0000 Zero adjustment m/s actual KFactory.000 Tube Size 0~00 mm 5~500 mm mm mm actual actual 5 Flow Rate Unit Liter 6 Flow Span Permitted maximum value 7 Liquid Density g/cm.0000 Low flow Cutoff Flow Direction Forward 0 Total Unit M Total Mode Forward Total Reset Cancel Fwd. Total Init. 0 Rev. Total Init. 0 I/O Signal Setting Parameter Option No. Unit Default ValueRemarks Damping Time Second Pulse Output Mode Pulse NO Pulse Output Unit Unit/pulse 0.0 L Max. Frequency HZ Output Curr. Mode 0 6 ma FineTune count 0 7 0mA FineTune count 0 Digital In Func None 9 Digital In Type NO Modbus ID BaudRate ModBus Comm. Data bit bit Parity none Stop bit bit 9

14 Alarm Setting No. Parameter Option Unit Default ValueRemarks Max. Flow Rate Min. Flow Rate Empty Tube Detct Disable Output func. Higher than the upper limit of flow rate 5 Output type NO 6 Output func. Higher than the upper limit of flow rate 7 Output type NO Curr. Func. N/A 9 Alarm Curr. Val. ma NO System Setting Parameter Option No. Unit Default ValueRemarks System language System info. Recovery Default Status of measuring pipe Current flowing speed m/s Traditional Chinese actual actual Selfdiagnosis Cancel Cancel Simulation Parameter Option No. Unit Default ValueRemarks Flow Speed Flow Rate Output Curr. Output Freq. Output status Output status Digital In Set m/s ma Hz ON ON ON Infomation Parameter Option No. Unit Default ValueRemarks Converter No. Firmware version actual actual 0

15 TUCHENG PLANT/YILAN PLANT

16 Global Network Germany China Taiwan U.S. U.S. Singapore Indonesia Asia North America Europe Taiwan FINETEK CO., LTD. Taipei Head Quarter No.6, Tzuchiang St., Tucheng Industrial Park New Taipei City 6, Taiwan TEL: FAX: California, U.S. APLUS FINETEK SENSOR INC. US Office 55 S. Lemon Ave, Suite D, Walnut, CA 979 TEL: FAX: Germany FineTeK GmbH Germany Office Frankfurter Str. 6, OG D65 Ruesselsheim, Germany TEL: +9(0)67600 FAX: +9(0) FINETEK CO., LTD. ILan Factory TEL: FAX: FINETEK CO., LTD. Taichung Branch TEL: 6705 FAX: 6706 Illinois, U.S. APLUS FINETEK SENSOR INC. TEL: 5 6 FAX: info@aplusfine.com FINETEK CO., LTD. Kaohsiung Branch TEL: FAX: China FINE AUTOMATION CO., LTD. Shanghai Factory No.5 DuHui Rd, MinHang District, Shanghai, China 009 TEL: FAX: info.sh@finetek.com Singapore FINETEK PTE LTD. Singapore Office No. 60 Kaki Bukit Place, #0706 Eunos Techpark Lobby B, Singapore 5979 TEL: FAX: info.sg@finetek.com Distributor: Indonesia FINETEK CO., LTD. Indonesia Office Ruko Golden Blok H No.0 Gading Serpong, Tangerang, Indonesia TEL: 6 (0)96 FAX: 6 (0)99 info.id@finetek.com 0EPD0B0EP, 0/0/06

Thermal Dispersion & Paddle Type Flow Switch.

Thermal Dispersion & Paddle Type Flow Switch. Thermal Dispersion & Paddle Type Flow Switch www.fine-tek.com PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch

More information

Thermal Dispersion Flow Switch.

Thermal Dispersion Flow Switch. Thermal Dispersion Flow Switch www.fine-tek.com PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch s probe contains

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

Thermal Dispersion & Paddle Type Flow Switch

Thermal Dispersion & Paddle Type Flow Switch www.fine-tek.com Thermal Dispersion & Paddle Type Flow Switch PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch

More information

PRODUCTS GUIDE. Total solutions for monitoring liquid levels in the Marine Industry

PRODUCTS GUIDE. Total solutions for monitoring liquid levels in the Marine Industry PODUCTS GUIDE Total solutions for monitoring liquid levels in the Marine Industry visit our website FineTek Co., Ltd. No.16, Tzuchiang St., Tucheng Industrial Park, New Taipei City 36, Taiwan. TEL: 886

More information

Pressure Level Transmitter.

Pressure Level Transmitter. Pressure Level Transmitter www.fine-tek.com C H 1 C H C H 1 C H PRODUCT INTRODUCTION FEATURES 1. FineTek Models include: extension cable transducer, Anti-corrosive model, flanged models & pressure transducers..

More information

Thermal Dispersion & Paddle Type Flow Switch. visit our website

Thermal Dispersion & Paddle Type Flow Switch. visit our website Thermal Dispersion & Paddle Type Flow Switch visit our website PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

INTRODUCTION FEATURES WORKING PRINCIPLE

INTRODUCTION FEATURES WORKING PRINCIPLE www.fine-tek.com INTRODUCTION ORKING PRINCIPLE The purpose of the rotary paddle level switch is to detect the presence of solid/powdery material in most kinds of tanks, bins and containers. The unit is

More information

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic Inductive Flowmeter EP / UMF2 (B) Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode

More information

Thermal Dispersion & Paddle Type Flow Switch.

Thermal Dispersion & Paddle Type Flow Switch. Thermal Dispersion & Paddle Type Flow Switch www.fine-tek.com PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

ISO-9001:2000 certified Aplus Finetek Sensor, Inc. SE3 Series Compact Rotary Paddle Point Level Sensor ISO-9001:2000 certified Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION PRINCIPLE The SE3 series is a compact rotary paddle point level sensor that uses

More information

Pressure Switch. visit our website

Pressure Switch. visit our website Pressure Switch visit our website SPST TYPE CE (need to add anti-dust cover SQA-1130. CE (need to add anti-dust cover SQA-1130. CE (need to add anti-dust cover SQA-1130. TYPE Hex length Body material rating

More information

Pressure Switch. visit our website

Pressure Switch. visit our website Pressure Switch visit our website SPST TYPE CE (need to add anti-dust cover SQA-1130. CE (need to add anti-dust cover SQA-1130. CE (need to add anti-dust cover SQA-1130. TYPE Hex Length Body rating (Max.)

More information

Rotary Paddle Level Switch

Rotary Paddle Level Switch www.fine-tek.com Rotary Paddle Level Switch INTRODUCTION WORKING PRINCIPLE The purpose of the rotary paddle level switch is to detect the presence of solid/powdery material in most kinds of tanks, bins

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WB Magnetic Flowmeter System Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Liquid Turbine Flow Meter OwnerÊs Manual

Liquid Turbine Flow Meter OwnerÊs Manual Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...

More information

SITRANS F M flow sensors 711/A and 711/911E

SITRANS F M flow sensors 711/A and 711/911E s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law

More information

Paddle Wheel Flow Meter

Paddle Wheel Flow Meter www.fine-tek.com Paddle Wheel Meter FineTek Lab FineTek is the company who owns a Second lass flow test laboratory in Taiwan. With the most professional R& team, FineTek develops various high precision

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Detector (for water measurement applications)

Detector (for water measurement applications) WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter

More information

Electromagnetic Flow Meter Owner s Manual HARDWARE

Electromagnetic Flow Meter Owner s Manual HARDWARE Electromagnetic Flow Meter Owner s Manual HARDWARE Compact Magnetic Flowmeter (Flange Connection) Sanitary Magnetic Flowmeter (Tri clamp Connection) Part No. 910000 Rev.C Content 1. GENERAL INFORMATION...2

More information

SHENITECH, LLC

SHENITECH, LLC SHENITECH, LLC Features and Benefits 100-H Tower Office Park, Woburn, MA 01801 Mag888 Electromagnetic Flow Converter The Mag888 flow converter is used together with the Mag888 flow sensor to form a complete

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

F6700 ELECTROMAGNETIC METER

F6700 ELECTROMAGNETIC METER EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy

More information

MagFlux Q 8200 Series

MagFlux Q 8200 Series MagFlux Q 8200 Series 3.06 ELECTROMAGNETIC FLOW METER General MagFlux Q Electromagnetic Flow Meter, created in composite materials, designed with an optimized construction which secures optimal performance.

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

Superstatic 440. Static Heat- and Cooling Meter. Application

Superstatic 440. Static Heat- and Cooling Meter. Application Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

UniMag DT Series Electromagnetic Flow Tubes

UniMag DT Series Electromagnetic Flow Tubes Description Spirax Sarco s UniMag DT Magnetic Flow Meter System consists of the patented UniMag Flow Tube and EFT10 Flow Transmitter. UniMag sensors are unique because they do not require a liner and can

More information

Solid / Liquid Level Measurement for Field Application Pneumatic Vibrator/Air Shocker Solution Temperature Controller/ Counter /Digital Panel Meter

Solid / Liquid Level Measurement for Field Application Pneumatic Vibrator/Air Shocker Solution Temperature Controller/ Counter /Digital Panel Meter Solid / Liquid Level Measurement for Field Application Pneumatic Vibrator/Air Shocker Solution Temperature Controller/ Counter /Digital Panel Meter By-pass Level Transmitter EF Series Material SUS316,

More information

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Electromagnetic Flowmeter Detector for Sanitary use MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable

More information

Electromagnetic flowmeter EMKO E

Electromagnetic flowmeter EMKO E Electromagnetic flowmeter EMKO E - Quality design - High corrosion resistance - Reliable measurement principle Doc. no.: 70, en_cat_emkoe, 8/2015 Description Electromagnetic Flowmeter EMKO E consists of

More information

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely

More information

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode

More information

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics Density Solution TDF Series Direct Insertion Density Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION flowmeter with paddle wheel, ELEMENT design INSERTION flowmeter with paddle wheel, design Up to PN, size of measurement pipes: DN to DN400 Configurable outputs: one or two transistor output(s) and single or dual 4... ma analog output(s) Removable

More information

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Botlek Studiegroep Basics Electro Magnetic Flowmeters Arjan Meerveld, ABB b.v. / 2 juni 2016 Botlek Studiegroep Basics Electro Magnetic Flowmeters ABB Group 8 June 2016 Slide 1 Measuring Principle of EMF Faraday s law (year 1831) Measurement electrodes Magnetic

More information

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters EMF Series ELECTROMAGNETIC FLOWMETER Description Introduction for EMF Series of Electromagnetic Flowmeters The Electromagnetic Flowmeters(EMF) can be used to accurately measure the flowrate of liquids,

More information

Electromagnetic flowmeter. Descriptions. Specifications

Electromagnetic flowmeter. Descriptions. Specifications Descriptions The EFM Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in HVAC, municipal or industrial water, wastewater, pump stations and packaged

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

RCM - Direct Reading Flowmeters

RCM - Direct Reading Flowmeters Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Electromagnetic amplifier type ModMAG M10 for all detectors

Electromagnetic amplifier type ModMAG M10 for all detectors Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors

More information

PMG MAGNETIC FLOWMETER

PMG MAGNETIC FLOWMETER PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Model TUR-200D Turbine Flowmeter

Model TUR-200D Turbine Flowmeter General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for diaphragm seal operation, Type series CI4330 Features Application area General process engineering Chemical and petrochemical industry General process

More information

VORTEX IN-LINE FLOW METERS

VORTEX IN-LINE FLOW METERS VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase

More information

Magnetic Inductive Flow

Magnetic Inductive Flow GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Magnetic Inductive Flow Characteristics

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

WATERFLUX 3000 Technical Datasheet

WATERFLUX 3000 Technical Datasheet WATERFLUX 3000 Technical Datasheet Electromagnetic flowmeter Easy installation without straight inlet or outlet lengths For installation in small spaces Wide range of approvals for potable water The documentation

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

BERMAD Waterworks. Insertion Flow Meter Device (IFM) IFM-MUT1222PRV BERMAD's IFM-MUT1222-PRV SENSOR is designed for measuring the flow rate of valves sized DN80 to DN600 (3-24 ). This document describes the installation process of the sensor. For larger

More information

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting

More information

HH5 Variable Area Flow meter

HH5 Variable Area Flow meter HH5 Variable Area Flow meter General Information HH5 series variable area flowmeteris a kind of measuring meter which the flow rate is changing along with the area and is widely used in the process control

More information

Electromagnetic flowmeters for water and seewage

Electromagnetic flowmeters for water and seewage 09/97 Electromagnetic flowmeters for water and seewage Primary head Compact flowmeters Installation instructions AQUAFLUX F 0 K 020 K 080 K CONTENTS Storage and transport Pagesn 3-4 Installation in the

More information

ProcessAutomatic EZ-Mag

ProcessAutomatic EZ-Mag ProcessAutomatic EZ-Mag THE EZ-CHOICE Robust Design: The highly robust and compact EZ-Mag is designed to be able to cope with tough environments. Whether installed in-house or on a vehicle, you can be

More information

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

Ultrasonic Flow Meter Series Smart-IN US. Features. Description Features Series 7200 is single-board, self-contained and state-of -the-art ultrasonic flow meter. It has the notable characteristics of high precision, high reliability, high performance, low price etc..

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

Flow - magnetic inductive - probe form

Flow - magnetic inductive - probe form GHM Messtechnik GmbH Hans-Sachs-Str. 6 938 Regenstauf Germany Fon +9 (0) 90-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - magnetic inductive - probe form Characteristics System

More information

MINI BY-PASS LEVEL INDICATOR

MINI BY-PASS LEVEL INDICATOR MINI BY-PASS LEVEL INDICATOR APPLICATIONS AND FEATURES It can be easily observed from the change of the flag color. Safer device comparing to glass type level gauge. Compact type, easy to install. Magnetic

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

Design and application

Design and application Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow

More information

RCM. Direct Reading Flowmeter. for Liquids or Gases

RCM. Direct Reading Flowmeter. for Liquids or Gases Direct Reading Flowmeter for Liquids or Gases measuring monitoring analyzing RCM Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas)

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Technical Information Proline Promag 10L

Technical Information Proline Promag 10L TI00100D/06/EN/1816 71326694 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with a weight-optimized sensor and highly cost-effectiveness Application The measuring

More information

Differential Pressure and Flow meters Accessories for the Media Series

Differential Pressure and Flow meters Accessories for the Media Series Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Instructions EM 101 Low Flow Electromagnetic Flow Meters PDF Published June 3, 2004 Instructions EM 101 Low Flow Electromagnetic Flow Meters Installation Mounting The EM 101 model has a flow meter unit and a separate control unit containing a LCD display. The

More information

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM Industrial Conductivity (Electric Conductivity) Detector A5/A6 type (For general multipurpose) AR4/AR5 type (for small purified water equipment) Dual electrode conductivity (electrical conductivity) detector

More information

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement process measurement solutions 7829 Visconic industrial viscosity transmitter on line real time viscosity measurement IP7001 w On-line real time viscosity measurement w Hazardous area approvals w 4-20mA

More information

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers

More information

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference

More information