1 IMPORTANT INSTRUCTIONS INSTALLATION AND STARTUP MODEL GDCP-A CONTROL PANEL WARNING USE OF HOUSING FOR FIELD WIRING WILL VOID THE FACTORY WARRANTY. Transmitter is considered water resistant only when the housing is connected to the conduit tubing with conduit access ports, (outlet bodies), rated for splicing, and compression fittings. Make all connections inside outlet bodies and secure all covers.
2 INSTALLATION and STARTUP INSTRUCTIONS GDCP-A CONTROL PANEL AND S To properly install this panel system, perform the following steps.. Determine the mounting location for the GDCP-A panel. 2. Determine the mounting location for all transmitters assigned to the panel. 3. Install the GDCP-A panel and all transmitters using the templates and mounting dimensions enclosed in the Important Papers package. 4. Open the door of the GDCP-A s cabinet. Using a small pair of cutters, clip and remove the plastic tie-downs at the right hand corners of the front panel/keypad door. Lift the front panel up and to the left to gain access to the panel P.C. boards. Connect each transmitter using a parallel, (daisy-chain), wiring scheme. Connect the panel to one of the closest transmitters in the group. All connections between the transmitters, and transmitter to panel, must be made using a five conductor, shielded cable. This cable should be composed of 8 AWG stranded conductors. The shield connection should be unbroken between cables, and the shield should be connected to earth ground at the GDCP-A panel only. See Fig. for more details. 5. Install a disconnect switch at the panel and connect a dedicated, 20 VAC, 50/60Hz. supply to the input of this device. Connect the output of the switch to the input power terminal strip, (), of the panel. This terminal strip is located at the top, left corner of the Power Supply/Relay board located on the inside, back of the GDCP-A s P.C. package. See Fig. 3 for the location of this P.C. board. Fig. 4 shows the typical wiring for the system. Connect the 20 VAC hot lead to the terminal marked L. Connect the neutral lead to the terminal marked. Any of the four terminals marked can connect to the supply s earth ground lead. 6. Determine the active zones for the system. Each zone has available two SPST dry contacts that are used to actuate the ventilation equipment controlled by the GDCP-A panel. Obtain a control voltage source, (maximum of 25 VAC), and connect to the appropriate relay terminal strips. There are six output control zones available, and each terminal strip is labeled with its zone number. Each strip is also labeled with the terms LA,, and. The terminals LA and are connected to the contacts for the Low Alert relay, while terminals and are connected to the contacts for the High Alert relay of that zone number. Most single fan systems will only use the LA and terminals. Staged fan systems may use both the LA/ and the / terminals. The control voltage is connected to the controlled device, (motor starter coil, etc.), with a wire connected to the appropriate or terminals.
3 7. If the system includes an external alarm device, connect the alarm control voltage and the alarm lead to the terminals marked AL and A at the center, right edge of the Power Supply/Relay board. 8. Perform a final, visual check of the system s wiring and correct any mistakes. After checking to make sure that the GDCP-A s power switch is in the OFF, (down), position, activate both the panel s 20 VAC supply and the zone control voltage source. Using a known good volt meter, measure the AC voltage at, terminals L and. This voltage should be 20 volts AC, +/- 2 volts. Also measure the zone control voltage level between LA and/or and the control voltage neutral or common lead. Determine that this voltage is also correct. 9. Once you have satisfied yourself that the wiring and the voltage levels are correct, place the power switch to the ON, (up), position. Close the door to the P.C. package, and inspect the front panel of the GDCP-A for the following: The green power indicating lamp is glowing. The display is indicating a date and time. The display s third and fourth line indicates that the system is warming up and asking you to wait until it has finished. This display will last for approximately 2 ½ minutes. No front panel keys will be active during this time. Depending upon the program, there may be specific zone Low Alert lamps and relays active. Whether this is the case depends upon the settings of the Power Back programming routine. After the 2 ½ minute period has elapsed, the system will enter the monitoring mode. All transmitters will be initially poled to determine the type and the present concentration. If all transmitters are responding properly, the panel s display will place the message, PRESS MENU FOR OPTIONS, on the third and fourth display lines. If any transmitters are not responding, the panel s display will indicate that it has found one or more inoperable transmitters. See the Installation/Operation manual, page 25, for the keystroke sequence on checking the transmitter status. Any transmitter that is not functioning can be identified using the status checking routine. 0. Unless you have requested that the GDCP-A panel arrive with a specific program installed, the panel will operate using the default program. See the manual for the specifics of this program, and how to change the parameters of the program to suit your specific requirements. Any questions that arise can be answered by contacting your Brasch distributor, or the Brasch service department. You can find the appropriate contact information on the GDCP-A s front panel label.
4 CAUTION This compartment contains hot wiring terminals, switches and fuses. Disconnect all remote supply sources before servicing this compartment. ATTENTION Ce compartment contient des branchements, interrupteurs et fusibles sous tension. De'brancher toutes les alimentetions avant d'effecteur toute re'paration. CAUTION This compartment contains hot wiring terminals, switches and fuses. Disconnect all remote supply sources before servicing this compartment. ATTENTION Ce compartment contient des branchements, interrupteurs et fusibles sous tension. De'brancher toutes les alimentetions avant d'effecteur toute re'paration. CAUTION This compartment contains hot wiring terminals, switches and fuses. Disconnect all remote supply sources before servicing this compartment. ATTENTION Ce compartment contient des branchements, interrupteurs et fusibles sous tension. De'brancher toutes les alimentetions avant d'effecteur toute re'paration. NOTES:. Remove power before opening housing. 2. See manual for installation/operation details. 3. Electrostatic sensitive device, observe proper handling procedures. NOTES:. Remove power before opening housing. 2. See manual for installation/operation details. 3. Electrostatic sensitive device, observe proper handling procedures. NOTES:. Remove power before opening housing. 2. See manual for installation/operation details. 3. Electrostatic sensitive device, observe proper handling procedures. Sensing Port Sensing Port Sensing Port Model: GSE-CM-DIG Model: GSE-CM-DIG CARBON MONOXIDE CARBON MONOXIDE NITROGEN DIOXIDE Model: GSE-ND-TRA Manufacturing Company, Inc. 880 Dorsett Road Maryland Heights, MO (866) MADE IN U.S.A. Mfg. Date: Mfg. Date: BRASCH Manufacturing Company, Inc. 880 Dorsett Road Maryland Heights, MO (866) MADE IN U.S.A. Mfg. Date: BRASCH S/N: BRASCH S/N: Manufacturing Company, Inc. 880 Dorsett Road Maryland Heights, MO (866) MADE IN U.S.A. S/N: SHIELD TO EARTH GROUND Using transmitter housing for field wiring will void warranty. Use conduit access ports, (outlet bodies), and compression fittings to connect transmitters to conduit and to complete all connections. Replace all covers to maintain water resistance. -M +M DIGITAL BOARD SEE FIG. 2 FOR LOCATION TO NEXT IN SEQUENCE, IF ANY. RED GREEN BLACK N/C +M BROWN -M BLUE TS2 CABLE LENGTHS UP TO 500 FEET CAN BE CONNECTED AS STRAIGHT DAISY CHAIN OR STAR PATTERN. LENGTHS ABOVE 500 FEET MUST BE STRAIGHT DAISY CHAIN AND TERMINATION RESISTORS OF 20 OHMS MUST BE PLACED AT THE PANEL AND AT THE FURTHERMOST IN THE CHAIN. SUGGESTED TERM. COLOR -M JP KEYPAD +M AND TS2 CAN BE USED TO CONNECT S. CONNECT UP TO TWO CABLES TO EACH TERMINAL STRIP, AS NEEDED. AND TS2 S FIG. : GDCP-A wiring diagram showing transmitters wired in "daisy chain" fashion, and location of terminal strips and TS2. See Fig. 2 for terminal strip locations.
5 DIGITAL BOARD BACKLIGHT POWER IN TP TS ma OUTPUT 6 MAX. SENSOR JP KEYPAD +M -M TS2 TRANS POWER IN JP3 + - JP2 POWER IN TP5 ZONE RELAYS +M -M P.C. PACKAGE FIG. 2: GDCP-A internal bottom view with cabinet door and P.C. package door open, indicating location of, transmitter wiring terminal strip.
6 L T T T XFMR- XFMR- XFMR- BACK BACK 2 XFMR- XFMR- XFMR- POWER TS9 OFF L POWER ON ZONE LA POWER POINTS SW OFF T T T ON ZONE LA P.C. PACKAGE POWER SUPPLY/ RELAY BOARD FIG. 3: GDCP-A power connection terminals.
7 20 VAC, 50/60 Hz. L DISCONNECT SWITCH SUPPLIED BY OTHERS L TS2 TS3 LA LA LA ZONE ZONE 2 25 VAC MAX. VENTILATION CONTROL VOLTAGE CONTROL RELAY COIL (Typical Connection) TS4 ZONE 3 LA TS5 ZONE 4 LA TS6 ZONE 5 TS9 POWER SUPPLY/ RELAY BOARD TS7 TS8 LA AL A ZONE 6 ALARM DIGITAL BOARD TS ma OUTPUT 4-20 Milliamp Multiplexed Output To BMS 6 MAX. SENSOR JP KEYPAD +M -M TS2 -M +M TO SYSTEM S FIG. 4: GDCP-A overall wiring schematic/diagram
8 TOP GDCP-A MOUNTING DIMENSIONS USE AT LEAST # 0 SCREWS. USE ALL FOUR MOUNTING HOLES. MOUNT ONLY INDOORS ON A SOLID FOUNDATION. BOTTOM GDCP-A cabinet mounting dimensions. GSE-TRA MOUNTING DIMENSIONS BACK VIEW GSE-CM-TRA and GSE-ND-TRA transmitter mounting dimensions.
TRAC-3 TENSION READOUT AND CONTROL
Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL TRAC-3 READOUT AND CONTROL For Control of Magnetic Particle
More informationACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit
More informationOptimized Idle Aftermarket Installation Kits On-Highway Truck Applications (P/N: )
18SP655 Optimized Idle Aftermarket Installation Kits On-Highway Truck Applications (P/N: 23538534) KIT DESCRIPTION The Optimized Idle Aftermarket Installation Kit provides the components necessary for
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18
Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationAssembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM
GENERAL REMARKS ON SAFETY: Read all of these instructions before installing fixtures. Keep all of the instructions for future reference. Turn off power before installing fixture. Installation is to be
More informationPRODUCT INFORMATION BULLETIN
724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery
More informationHP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control
SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains
More informationGeneral Description. Product Specification. Document Digital Temperature Interlock
Document 474751 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the
More informationExcel 15 W7760A BUILDING MANAGER
Excel W0A BUILNG INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The Excel W0A Building Manager is a freely configurable controller that can be used to monitor and control H equipment and other miscellaneous
More informationSentinel Field Satellite Controller
WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning
More informationHYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS
HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS INTRODUCTION... 2 SPECIFICATIONS... 2 INSTALLATION... 3 PC Board Mounting...3 Sensor Installation...3 Manifold Assembly...4
More informationPowerLogic High Density Metering System 4-Meter Enclosure Installation Guide
PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment
More informationGSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version
GSC300 Auto Start Engine Controller Installation and User Manual for the GSC300 Auto Start Engine Controller Full Version File: GSC300rev2.4.doc Dec. 08, 2005 2 Thank You For Purchasing This DynaGen Product
More informationINSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.
103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com
More informationE.S.P. Embedded Sensing Probes for Motor Brushes
E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14
Zone Sensors Submittal Data English Language/IP Units SD1582EW 10/14 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationMETROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide
METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide Copyright 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced,
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationPre-plumbed Blowdown Assembly ½ Model
Pre-plumbed Blowdown Assembly ½ Model 7760013 The pre-assembled blowdown configurations reduce installation time and component placement error. Each part of the assembly may also be ordered separately.
More informationUL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD
UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you
More informationRAPID Environment Control INSTALLATION GUIDE. Ver 99C. RAPID Environment Control. Creep
RAPID Environment Control INSTALLATION GUIDE Ver 99C RAPID Environment Control 1 2 3 4 5 6 7 8 9 0 Room Ambient Creep S Y S T E M S Variable Ouput 2 Indicator Variable Ouput 1 Indicator S Y S T E M S Increase
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More informationmodel ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION
MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.
More information60 Series Engine Controls
ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery
More informationSeries BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1
Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]
More informationOperations Manual. Zero Speed Switch Sensor Model ZS09P
Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P
More informationInlet Controller SB3500 USER'S MANUAL
Inlet Controller USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice
More informationACC Series Power Conditioner OPERATION & INSTALLATION MANUAL
ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide
More informationProduct Data Sheet. Damper Interface. Features
Damper Interface Product Data Sheet Features Damper Motor drive and limit switch monitoring integrated into a single unit Dual limit switch inputs for confirmation of damper-fully-open and damperfully-closed
More informationCIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT
GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS
More informationInstallation & Instruction Manual for PCS-2000 Proofer Control System
June 2001 Installation & Instruction Manual for PCS-2000 Proofer Control System W. H. Cooke & Co., Inc. 6868 York Rd. Hanover, PA 17331 Phone: 1-800-772-5151 www.whcooke.com Table of Contents Introduction....................................
More informationMAXLITE RKT LED Retrofit Kit
MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent
More informationCV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY
CV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY 1 TABLE OF CONTENTS 1.0 Specification 5 2.0 Installation 7 2.1 Rack Mounted 7 2.2 Cooling 7 2.3 Filament Module 8 2.4 Electrical Power Input 8 2.5 Grounds
More informationSAX Electronic Valve Actuator
SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires
More informationFan Coil Unit (FCU) Fan Motor Control
Fan Coil Unit (FCU) Fan Motor Control Fan Relay Board 2 (FRBii) Installation, Operation, and Maintenance The Fan Relay Board assembly (FRBii) provides electronic control for the fan motor and various connections
More informationPART B BRAND SPECIFIC MANUAL
SPA OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS PART B BRAND SPECIFIC MANUAL ELECTRICAL CONNECTION KEYPAD OPERATION 200 Series 200-M-B-16 Read in conjunction with Part A General Manual to form a complete
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More information3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter
pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color
More informationINSTRUCTION MANUAL A141 High Level Audible Warning System / Battery backup
Control Panel Unit Type No. A141AC230GB Input Voltage: 115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP65 Marking: Control Unit weight : 23kg 3) Installation Requirements
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the CO level and outputs a 4-20 ma signal. The standard product features a 2- wire loop-powered output. Optionally, the device
More informationTWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A
TWIN FAN Installation and Wiring Instructions Models:- ITC and ITC-DS Maximum load : 220-240V 50Hz ~ 9A and 380-415V 50Hz 3 ~ 9A IMPORTANT - READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION.
More informationHAN-L62 MOUNTING PLATE
DATE : 23/01/2013 BULLETIN NO : L62-132E-INST-REV11 SUPERSEDES : 30/11/2012 Z ABN 92 431 001 201 INSTALLATION INSTRUCTIONS FOR MODEL HAN-L62 / PCB-132 WITH EARTH SHIELD CABLE MICROPROCESSOR AIR CONDITIONING
More informationIMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE
USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General
More informationRequirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING
CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO
More informationCascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75
Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve
More informationA.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual
Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323
More informationSE8300 Series Installation Guide 24 Vac Low Voltage
Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification
More information- Wiring Brochure tn4 Gateway 483
- Wiring Brochure Gateway 483 W 483 03/10 1 Infmation Brochure Application Brochure Choose controls to match application Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring Brochure
More informationFan Relay Board (FRBii) Assembly
Fan Relay Board (FRBii) Assembly Installation, Operation, and Maintenance Instructions PK-FCU030-0, PK-FCU050-0 Part No. 24-10143-1221, Rev. A Issued February 2017 Application Refer to the QuickLIT website
More informatione-ask electronic Access Security Keyless-entry
e-ask electronic Access Security Keyless-entry Multiplex System Multiplex System Installation & Instructions (UM15 ~ 22272-03) Table of Contents Introduction... 1 Standard e-fob Operation and Features...
More informationPrecision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL
POWER CONVERSION/DISTRIBUTION Precision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL 3 Phase 15 kva - 225 kva 50 & 60 Hz TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has
More informationCSD Series Current Devices Split Core
CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch
More informationPower Supplies. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high effi ciency and compact size with new visual diagnostic LEDs
More informationInstallation Instructions
Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates
More informationInstallation Instructions & Users Manual
Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL
More informationModel H30 Operation Manual
Model H30 Operation Manual Model H30 Version 1.0 August 1, 2007 2 135 West Davenport Street Rhinelander WI 54501 Phone: 866.441.7997 Fax: 866.278.0036 info@houstonst.com www.houstonst.com 3 Table of Contents
More informationDigital Room Thermostats with Touch Screen LCD
TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),
More informationELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators
ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators BECAUSE CLEAN AIR MATTERS Note: Factory trained or suitably qualified personnel must perform this installation. General:
More information1100 Series Piston Type Differential Pressure Gauges
1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.
More informationArt. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2
SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...
More informationL5000 Plus. Installation & Setup Guide
L5000 Plus Page 1 of 16 JDE1945 IssB s1 May 2009 Contents Description Page Safety... 3 Installation Standards 4 Specification. 4 Installation Procedure Pump Box. 6 Auxiliary Pump Boxes... 7 Connecting
More informationModel APS-25CH Installation Manual
Model APS-25CH Installation Manual Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver s do pin switch in der to begin the passive arming sequence. RF Programmable
More informationRequirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING
CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions
More informationCOMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012
COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER
More informationAutomatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit
Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.
More informationExcel 10 W7751J Smart VAV Actuator
Excel 0 W775J Smart VAV Actuator BEFORE INSTALLATION INSTALLATION INSTRUCTIONS The W775J Smart VAV Actuator is a factory-combined Excel 0 Variable Air Volume (VAV) Box Controller and an ML66B Direct-Coupled
More informationInstallation Instructions
Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationHomeWorksR QS Wired MaestroR Architectural Local Controls
HomeWorks QS Wired Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationGSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.5
GSC400 Series Automatic Gen-Set Controller Manual Revision 2.5 GSC400 Automatic Gen-Set Controller Installation and User Manual Full Version File: GSC400 User Manual Rev2.5.doc, December 2009 2 of 98 Thank
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE
More informationApplication. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)
TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2600 SASH SENSING VAV FUME HOOD SYSTEM MODEL 2600: Variable volume control based on sash position utilizes microprocessor based electronics and linear air control
More informationPF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016
PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication
More informationUser Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring
User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationRP-4000 Reserve Power Control
Instruction Manual IM-0580 RP-4000 Reserve Power Control Table of Contents General Information... 2-3 Introduction... 2 Cautions... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Identification
More informationFreedom egen System End-of- Line Functional Checklist
U Freedom egen System End-of- Line Functional Checklist 976-0361-01-01 Rev A April 2018 DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This checklist is in addition to, and incorporates
More informationQ&A FOR Webinar on Electrical Basics & Boiler Wiring
Q&A FOR Webinar on Electrical Basics & Boiler Wiring 4-20-16 Q: Is a dual fuel burner flame guard system more complicated than the one you showed us today? A: Not really. If the boiler is equipped for
More informationD4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -
Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head
More informationComfortPoint Programmable Lon, VAV/Unitary Controllers
ComfortPoint Programmable Lon, VAV/Unitary Controllers Controller Model Programmable Type Universal Inputs (UI) Table 1. Controller configurations. Digital Inputs (DI) PRODUCT DESCRIPTION INSTALLATION
More information- Wiring Brochure Zone Manager 335
- Wiring Brochure W 335 12/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications Rough-in Wiring Rough-in wiring instructions 3 4 Wiring
More informationHandyman Motor Capacitor Meter PART NO
Handyman Motor Capacitor Meter PART NO. 2225174 To test a motor-run capacitor in the field with no capacitance meter at hand, you had to hook up the capacitor through an extension cable to a 120V wall
More informationOEM Manual. 4042SA Leak Detecting Spill Alarm Instruction manual
OEM Manual 4042SA Leak Detecting Spill Alarm Instruction manual 1 These instructions generally describe the installation, operation, and maintenance of, subject equipment. The manufacturer reserves the
More informationSturdy Truck Body Poultry Shipping Truck - Operations Manual August 2003
1.0 Introduction The Sturdy ventilation controller is designed to automatically control indoor air quality including: temperature, relative humidity, carbon dioxide and oxygen in the interior of the vehicle
More informationESV. Electronic Steam Valve Control Modulates One or Two Actuators. Installation and Operation Manual ESV. Control Module
Installation and Operation Manual Electronic Steam Valve Control Modulates One or Two Actuators ESV ACTUATOR SIGNAL 8psi 9psi BACK MENU/SET INPUT RATINGS: 120VAC 60HZ, 48 VA ESV Control Module Warning
More information- Wiring Brochure Zone Manager 336
- Wiring Brochure W 336 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring Brochure Wiring
More informationTS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY
TS1 SMARTBOB REMOTE UNIT INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 No. 98th Street P.O. Box 29709 Lincoln, NE 68507 Lincoln, NE 68529 (402) 434-9102
More informationGP Dimming Panels 230 Volt (CE)
GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim.
More informationPowerware Vdc Extended Battery Cabinet User s Guide.
Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital
More informationElectro-Mechanical Swing Operator. Table of Contents
*640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product
More informationFM SECURITY AND REMOTE START SYSTEM
FM SECURITY AND REMOTE START SYSTEM INSTALLATION MANUAL BEFORE INSTALLING THIS PRODUCT PLEASE READ THIS INSTALLATION MANUAL THOROUGHLY!! This system is intended for installation on vehicles equipped with
More informationARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI
II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,
More informationEvolution. ECM Motor. T Control CONTROLS INC. EVO /ECM-DTC16. Differential Temperature Control. Specifications. Applications
T Control CONTROLS INC. EVO /ECM-DTC16 Differential Temperature Control The EVO/ECM-DTC16 sets the ECM motor speed depending on the temperature difference measured by two temperature sensors. The DTC16
More informationCHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR
WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. Supersedes: 160.80-PW4 (1099) Form: 160.80-PW4 (215) FIELD CONNECTIONS ROTARY SCREW CHILLER WITH GRAPHIC CONTROL CENTER AND YORK MOD
More informationYG101 SWING GATE OPENER OWNER S MANUAL
YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician.
More information