3 Protector Laboratory Fume Hoods & Enclosures Overview Since the manufacture of our first product in 1925, the Kjeldahl Apparatus, Labconco has focused on finding effective ways to remove chemical fumes from the laboratory. That knowledge and experience led to the development of our first molded fiberglass-lined fume hoods in We continue to build on that expertise today as we refine our designs to exacting standards and adapt to the changing needs of the marketplace. The result is the broadest, most comprehensive and innovative line of laboratory ventilated enclosures available anywhere. Labconco is ISO 9001 certified, one measure of our commitment to quality and consistency in manufacturing. We back our quality products with outstanding customer service. Whether you need a single fume hood and all its required system components, a unique custom-designed fume hood to handle a special application, or an entire building of fume hoods and supporting casework, Labconco technical specialists are ready to help you throughout the process. With our worldwide network of distributors, we are dedicated to providing quality products and service to meet your requirements and exceed your expectations. Table of Contents Overview Chemical Fume Hoods and Enclosures Selection Guide Carbon-Filtered Enclosures Selection Guide Applicable Standards Protector Premier Laboratory Hoods Protector XStream Laboratory Hoods Protector XL Laboratory Hoods Protector XL Floor-Mounted Laboratory Hoods Protector ClassMate Laboratory Hoods Protector Stainless Steel Radioisotope Laboratory Hoods Protector Stainless Steel Perchloric Acid Laboratory Hoods Protector PVC Perchloric Acid & Acid Digestion Laboratory Hoods Basic Laboratory Hoods Fiberglass 30 Laboratory Hoods Paramount Filtered Enclosures Paramount Electric & Manual Hydraulic Lift Base Stands Paramount Filtered Enclosures Accessories Protector VS Ventilation Stations Protector FilterMate Mobile Stations Color-Smart Filter Cells Protector VS Ventilation Stations & Protector FilterMate Mobile Stations Accessories Demonstration Hood Canopy Hoods Fume Adsorbers Protector Work Stations SpillStopper Work Surfaces Flat Work Surfaces Base Stands & Storage Cabinets Selection Guide Telescoping Base Stands Electric & Manual Hydraulic Lift Base Stands Protector Acid Storage Cabinets Protector Solvent Storage Cabinets Protector Standard Storage Cabinets Protector Vacuum Pump Storage Cabinets Accessories Index by Catalog Number Conversion Factors Inside Back Cover Blowers Booklet Back Pocket

4 Protector Laboratory Fume Hoods & Enclosures Overview Built To Exacting Standards Protecting your laboratory environment is the foundation of our product development, and every Labconco fume hood and enclosure is designed with safety in mind. Our fume hoods are rigorously tested and conform to a long list of government and independent agency standards that specify safe construction and performance criteria for laboratory hoods: Occupational Health and Safety (OSHA) Federal Register 29 CFR Part 1910 Industrial Ventilation, American Conference of Governmental Industrial Hygienists American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) ANSI Z Scientific Equipment & Furniture Association (SEFA) National Fire Protection Association (NFPA) American Society for Testing and Materials (ASTM) E84-01 Underwriters Laboratories (UL) 1805 UL / Canadian Standards Association (CAN/CSA) C22.2 No European Community (CE) Brief explanations of these standards can be found on page 9. Throughout the catalog, the specific regulations and standards met by each style of hood are provided in the ordering information. To ensure that our hoods meet or exceed ASHRAE , Labconco engineers rigorously test newly designed fume hoods and routinely test randomlyselected hoods from our product line in Labconco s airflow test laboratory. Besides internal testing, many of our hoods undergo stringent testing and certification by an unbiased independent organization, Intertek Testing Services (ITS). ITS, which acquired ETL Testing Laboratories in 1996, is recognized by OSHA as a Nationally Recognized Testing Laboratory (NRTL) just as UL, CSA and several other independent organizations As part of ASHRAE , a tracer gas is released at an established rate and at various positions within the hood. The gas is monitored in the breathing zone of a mannequin placed at various positions in front of the hood. Based on the release rate of the tracer gas and the average exposure in the breathing zone, a performance rating is determined. An As Manufactured (AM) rating of 0.05 part per million (ppm) or less is considered effective containment. are recognized. A federal law passed in 1988 established the NRTL program to eliminate provisions that explicitly required or implicitly implied that product certification be performed only by standard-writing companies such as UL. Since each NRTL must meet the same OSHA competency requirements, NRTLs recognized for the same product safety test standard are considered equivalent in the capability to certify to that standard. Labconco fume hoods with the ETL mark have been certified to UL 1805 and/or UL / and CAN/CSA Standard C22.2 No Products that bear the ETL mark are subjected to a comprehensive safety program that includes testing, listing, labeling and quarterly follow-up inspections. For a current list of Labconco products bearing the ETL mark, go to Labconco fume hoods designed for international 230 volt, 50 Hz operation carry the CE mark. The CE mark indicates that the product conforms to all safety and other directives/specifications presently required by the Council of European Communities. The CE mark was established in 1993 to standardize European countries electrical directives into a single set of regulations, eliminating barriers to trade. Present rules require that products meet electrical safety requirements set for laboratory equipment and also pass electromagnetic emissions testing (interference signals being output by the product) and electromagnetic immunity testing (the product should not respond to outside electromagnetic interference signals). An independent outside agency tests and confirms Labconco hoods conformity to electromagnetic emissions and immunity standards. Protector first choice in hoods The Protector line of laboratory hoods offers you choice. Protector Hoods run the gamut of styles that fit a full range of applications from general chemistry to perchloric acid use. Liner materials include one-piece molded fiberglass, fiberglass-reinforced composite panel, stainless steel, PVC and tempered safety glass. Whatever your laboratory situation demands, there s a Protector Laboratory Hood to meet your needs. Defining Features Consistent among Protector Hoods are several defining features that set them apart from the rest. Sleek exteriors with durable glacier white epoxy coating complement laboratory casework and allow compatible mixing and matching of several hood types. The ergonomic air foil with Clean-Sweep openings is so unique it is patented.* The aerodynamic curve of the air foil allows air to sweep the work surface for maximum containment. Clean-Sweep openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant protective barrier that keeps contaminants away. In addition, should the operator inadvertently block the air flowing across the air foil, air continues to enter from beneath and through the Clean-Sweep openings. * U.S. Patent No. 6,461,233 1

5 Protector Laboratory Fume Hoods & Enclosures Overview 2 Side view of an air foil with Clean-Sweep openings illustrates airflow entering over, through and under the air foil. When the operator blocks the front of the air foil, air enters from under the air foil so dead-air zones are minimized and containment maintained. Protector corner posts have a streamlined shape to enhance containment and are epoxy-coated for chemical resistance. Switches and electrical receptacles mounted on the corner covers meet Americans with Disabilities Act (ADA) height requirements. Also mounted at ADA height on the corner posts are color-coded service fixtures. Each service type has a sculpted, colored knob and matching interiormounted hose connector for easy service identification and comfortable grip. Color-coded fixtures provide at-a-glance service type identification. Access plates on the corner posts provide front access to plumbing to simplify installation and service. Cover plates feature hood operating instructions, providing constant reminders to work safely in the hood. Front cover plates may be easily removed for quick access to service valves. Protector Premier Laboratory Hoods superior molded fiberglass liner Protector Premier Laboratory Hoods feature interior liners molded of specially formulated fiberglass reinforced polyester. The one-piece, glossy fiberglass liner has been the signature feature of Labconco s leading line of general chemistry fume hoods since its development by Labconco engineers in Benefits you can expect from fiberglass include durability, cleanability, high light reflectivity, fire resistance and chemical resistance. Labconco fiberglass withstands exposure to a wide range of laboratory acids, solvents and alkalies. It will not absorb spills and resists staining and discoloration. The smooth one-piece surface with radiused corners has no cracks or crevices for contaminants to collect, so maintenance is minimal. The following chart of chemical resistance for Labconco fiberglass material is based on ASTM Test C in which 4" x 5" samples are immersed in reagents for one to three months or longer. Fiberglass Chemical Resistance Protector XStream Laboratory Hoods high performance, energy savings Protector XStream Laboratory Hoods represent Labconco s newest and most innovative fume hoods. Labconco engineers adopted a unique approach when designing these high performance laboratory hoods that may operate as low as 60 fpm to provide a 40% energy savings. Patented* features work together to keep all areas behind the sash opening free of contaminants. To ensure that containment was maintained under adverse conditions, they developed variations of the ANSI/ASHRAE Standard to challenge the Protector XStream Hood. They tested the hood s containment limit by changing temperatures and face velocities, differing sash heights and adding interior obstructions, cross drafts and door movements. In every instance, the Protector XStream showed tracer gas leak levels below the acceptable ASHRAE level of less than 0.05 ppm. Labconco used computational fluid dynamics (CFD) to build a model of the Protector XStream Hood and validate successful ASHRAE test results. CFD predicts fluid flow behavior and provides a means of visualizing the airflow. Like the tracer gas in ASHRAE testing, CFD was used as a tool to test the hood s performance. Design features were fine-tuned based on CFD test results until performance was optimized. The illustrations in Figures 1 and 2 are actual CFD outputs. Reagent Satisfactory For Satisfactory For Slight Discoloration Normal Use Occasional Use with Heavy Use Acetic Acid Acetone (50%) Ammonium Hydroxide Benzene Fatty Acids Formaldehyde (44%) Hydrochloric Acid Hydrofluoric Acid Hydrogen Peroxide Naphthalene Nitric Acid (35%) Peracetic Acid Perchloric Acid Use only in Protector Stainless Steel or PVC Perchloric Acid Hood. Petroleum Ether Phosphoric Acid Tannic Acid Sulfuric Acid (50%) * U.S. Patent No. 6,461,233

6 Protector Laboratory Fume Hoods & Enclosures Overview Figure 1: The Protector XStream Hood s velocity vector at 60 fpm is shown on a plane through the center of the hood. The horizontal laminar air vectors turn downward as they reach the perforated baffle. The Protector XStream Hood shows diminished vortex roll, thereby reducing air turbulence and instability in the hood. Transparent glass backs and baffles provide a clear view through these Protector ClassMate HOPEC IV Laboratory Hoods mounted back-to-back on peninsular casework at this university laboratory. Figure 2: Sulfur hexafluoride (SF 6 ) gas is emitted from the ejector on a plane through the center of the hood at 4 liters per minute. The Protector XStream Hood is operating at 60 fpm with the sash fully open. The area near the sash plane where the operator would stand and work is dark blue indicating it is free of contaminants. The concentrations of contaminants, shown in orange, are contained deep within the interior of the hood so that contaminants can be exhausted in a single pass. Protector ClassMate Laboratory Hoods for instructional laboratories Patented* Protector ClassMate Laboratory Hoods have clear sides, back and baffle for visibility from all sides. A stationary glass viewing panel above the sash frame creates a 39" viewing height. They are ideal for advanced educational settings where students need to observe demonstrations conducted in the hood or the instructor needs to supervise students using the hood. Protector XL Laboratory Hoods broadest range of sizes and options Protector XL Laboratory Hoods have a flexible platform for customization of features and dimensions. Their liners of durable fiberglass-reinforced composite panels may be configured in a variety of widths and depths to match architect specifications. Benchtop models are offered in widths from 4 to 16 feet and three depths. Protector XL and ClassMate HOPEC IV Laboratory Hoods energy savings and enhanced accessibility Protector XL and ClassMate Hoods are available designed to HOPEC IV specifications. The hand-operated, positive energy control fume hood (HOPEC) design addresses ADA accessibility, energy and safety concerns. Using these concepts, Labconco engineers applied their ventilation expertise to the design of Protector XL HOPEC IV Laboratory Hoods and Protector ClassMate HOPEC IV Laboratory Hoods. The sash viewing area is taller than traditional hoods, which permits mounting the hood in either a high or low position while maintaining usable access. This feature is important when a hood must be mounted low for wheelchair accessibility while also being used by individuals standing at the hood. On most hoods, the sash is a combination horizontal-sliding/ vertical-rising design to reduce airflow requirements. The patented** air foil, with Clean-Sweep openings and ergonomic recessed sash track, is designed to provide user safety and comfort without excessive cabinet overhang. For energy efficiency, a sash stop limits the sash opening height to 50%. The sash stop in combination with a by-pass block reduce the total amount of air exhausted from the hood. To further limit the sash opening, the upper portion of the sash is stationary so that energy conservation does not compromise visual accessibility. Safety features include a digital airflow monitor to alert the user to low velocity conditions, a sash pocket to prevent laboratory exposure to contaminated interior sash surfaces as the sash is raised and a highly visible safety yellow air foil with integral trough to contain spills. Protector XL HOPEC IV Hoods have a unique air foil/spill trough that keeps large spills contained. This safety feature is particularly important for users with limited mobility who cannot react quickly to accidents. * U.S. Design Patent No.472,645 ** U.S. Patent No. 6,461,233 3

7 Protector Laboratory Fume Hoods & Enclosures Overview Protector XL Floor-Mounted Laboratory Hoods for maximum work area Protector XL Floor-Mounted Laboratory Hoods have additional interior height to accommodate large apparatus. Hood interior depths from 30" to 48" and widths from 4' to 16' are available. Since they mount on the floor, these hoods permit roll-in loading of heavy or bulky apparatus. Protector Special Application Laboratory Hoods for radioisotope, perchloric acid or heavy acid use Applications involving radioisotopes, perchloric acid and acid digestion require laboratory hoods with specialized features. Protector Stainless Steel Radioisotope Hoods have fully sealed integral work surfaces and coved interiors to facilitate decontamination. Labconco offers two perchloric acid hoods: the Protector Stainless Steel Perchloric Acid Hood and the Protector PVC Perchloric Acid Hood. These hoods feature washdown systems, integral work surfaces and drainage troughs so that they may be thoroughly rinsed after each use to prevent the accumulation of potentially reactive perchloric salts. Protector PVC Acid Digestion Hoods feature Lexan* sashes, recommended for hydrofluoric acid use. 4 Protector Perchloric Acid and Acid Digestion Hoods feature a built-in washdown system consisting of plumbing connected to a control knob and spray nozzles located along the top interior. Labconco offers you choices The Selection Guides on pages 6-8 provide an at-a-glance listing of the fume hoods, ventilated enclosures and carbonfiltered enclosures offered in this catalog. The discussion that follows provides some of the factors to consider when choosing a laboratory ventilation system. The Selection Guides help you find the Labconco fume hoods and enclosures with the characteristics you require for your system. Types of Exhaust Systems Fume hoods use one of two types of exhaust systems: constant air volume (CAV) or variable air volume (VAV). The fume hoods offered in this catalog have been designed to be used with a constant volume system and can be easily modified for use with a variable air volume system. Contact Labconco for ordering information on variable air volume modifications. Constant volume hoods come in conventional, by-pass, high performance by-pass and auxiliary-air types. All Labconco fume hoods feature by-pass or high performance by-pass airflow design. Protector Premier and XL Laboratory Hoods may be modified to an auxiliary-air design with an accessory Auxiliary-Air Plenum Kit (see page 110). By-Pass By-pass hoods have a movable, fullyclosing front sash and an interior baffle. These hoods are designed so that as the sash is being closed, the air entering the By-Pass Airflow Design Upper By-Pass Opening Front Sash Ergonomic Air Foil with Clean-Sweep Openings Lower By-Pass Opening hood is redistributed via by-pass openings above and below the sash. These openings help to stabilize airflow and eliminate high velocity air streams that can disturb delicate procedures or instrumentation in the hood. All Protector Premier, XL, Stainless Steel and PVC Hoods as well as Basic and Fiberglass 30 Hoods include the by-pass feature. Protector HOPEC IV Hoods have a modified by-pass design the by-pass openings above the sash are blocked to reduce air volume demand. High Performance By-Pass Protector XStream Laboratory Hoods feature high performance by-pass design. Like a by-pass hood, they have a fullyclosing sash, by-pass openings above and below the sash, and stable airflow regardless of sash position. Unique patented** features such as the Upper Dilution Air Supply, Rear Downflow Dual Baffle System, Containment-Enhancing Sash Handle and Ergonomic Air Foil with Clean-Sweep Openings contribute toward improving containment by directing airflow toward the rear of the interior in horizontal laminar flow-like patterns. Since containment is enhanced, these hoods can operate at face velocities as low as 60 fpm, thus conserving energy and providing an alternative to auxiliary-air hoods in air-starved laboratories. High Performance By-Pass Airflow Design Upper By-Pass Opening Upper Dilution Air Supply Front Sash Containment- Enhancing Sash Handle Ergonomic Air Foil with Clean-Sweep Openings Lower By-Pass Opening Size Labconco offers hoods in a range of sizes from compact Fiberglass 30 Laboratory Hoods to Protector XL Laboratory Hoods as wide as 16 feet. OSHA 29 CFR recommends laboratories provide an average of 2.5 linear feet of hood space per person. Sash Configuration Most Labconco Hoods have vertical-rising sashes. Vertical-rising sashes may be lifted to the completely open position offering the maximum area for loading materials and apparatus. During operation, the sash should be lowered to provide a barrier to protect the user from splashes and chemical reactions. Vertical-rising sash *Lexan is a registered trademark of General Electric Company. **U.S. Patent No. 6,461,233

8 Protector Laboratory Fume Hoods & Enclosures Overview Horizontal-sliding sashes allow the user to reach around both sides of the sash while using the sash as a shield. Horizontal-sliding sashes provide a smaller maximum sash opening approximately one-half the size of vertical-rising sashes. Because their sash openings are smaller and less air volume is exhausted, hoods with horizontal-sliding sashes conserve energy. Protector XL Floor-Mounted Hoods in widths from 8 to 16 feet have horizontalsliding sashes. Horizontalsliding sashes Combination vertical-rising/horizontalsliding sashes offer the advantages of both sash types. For energy conservation, the hood s air volume is based on its smaller horizontal-sliding sash opening (generally 50% of the full open position). To maintain safe face velocities, sash stops limit opening the vertical-rising sash beyond 50% except when deliberately released by the operator during loading or unloading. Protector XL and ClassMate HOPEC IV Hoods have combination sashes. Combination sashes on other hood models are available upon request. Combination verticalrising/horizontalsliding sashes Pivoting sashes are found on Paramount Filtered Enclosures and Protector VS Ventilation Stations. These enclosures have a small permanent sash opening height that restricts energy usage. The sashes may not be fully closed but may be pivoted up to a full open position for loading of materials. Pivoting sash Remote Blower vs. Built-In Blower Most laboratory hoods are designed for use with remotely located blowers. Of all the components required to complete a laboratory hood ventilation system, the blower is the most crucial to the hood s performance. Labconco offers a variety of blowers and exhaust devices sized for our hoods. The Blowers Booklet located in the back pocket of this catalog provides further information on our Coated Steel, Fiberglass and PVC Blowers, Air Ejectors, Swirlaway Fume Scrubbers and Ductwork. Selected models of Protector Premier Hoods in 4', 5' and 6' widths, Basic Hoods, Fiberglass 30 Hoods, Demonstration Hood and Carbon Filtered Enclosures have built-in blowers. Easy to install, these hoods feature blowers sized to accommodate relatively short, uncomplicated duct runs. Contact Labconco at or for technical assistance regarding the use of hoods with built-in blowers. The built-in blower in this Protector Premier Laboratory Hood is visible when the front panel is removed. Hood Liner Materials Liner Material Labconco offers a variety of liner materials. Protector Premier and Fiberglass 30 Laboratory Hoods are lined with molded, one-piece fiberglass. Protector XStream and XL Hoods have fiberglass-reinforced composite panel liners. Protector Radioisotope and Perchloric Acid Hoods have stainless steel liners. Other Protector Perchloric Acid and Acid Digestion Hoods have PVC liners. Protector ClassMate Laboratory Hoods, Protector VS Ventilation Stations and Paramount Filtered Enclosures have interiors that use tempered safety glass and epoxy-coated aluminum channel construction. Basic Laboratory Hoods are epoxy-coated steel inside and out. The best liner material for your hood should be determined by the applications, types and concentrations of chemicals that will be handled in the hood and exhaust system. Hood liners are subject to attack from acid fumes and solvent vapors by: (1) corrosion (the destruction of metal or other material by chemical or electrochemical action), (2) dissolution (a dissolving action to which coatings and plastics are subject), and (3) melting (occurs with certain plastics and coatings at elevated operating temperatures). The Hood Liner Materials table below describes the characteristics of the various liner materials found in Labconco hoods and enclosures to help you select the right ventilation product for your application. Liner Stain Moisture Chemical Heat Flame Material Resistance Resistance Resistance Resistance Spread Index* One-piece, molded fiberglass Good Excellent Excellent Very good 25 Fiberglassreinforced Good Excellent Excellent Very good 25 composite panel Tempered safety glass Excellent Excellent Excellent Very good 0 Stainless steel Good Excellent Good Excellent 0 (Type 316 or 304) resistance to a wide range, subject to attack by some acids Polyvinyl chloride (PVC) Very good Excellent Excellent Poor. 20 except for Will distort some solvents at 160 F Epoxy-coated steel Good Very good Good Very good 5 * The lower a material s flame spread index, the greater its flame-retarding capabilities. NFPA 45 Standard on Fire Protection for Laboratories Using Chemicals states that materials of construction should have flame spread of 25 or less. The flame spread index is determined using ASTM E84 test method which compares the surface flame spread and smoke development measurements of a particular material to those obtained from tests of standard calibration materials at the opposite ends of the spectrum mineral fiber cement board (flame spread index = 0) and select grade red oak flooring (smoke spread index = 100). The test specimen surface, 18" wide x 24' long, is exposed to a flaming fire for 10 minutes. Flame spread over its surface is measured and recorded. Test results are presented as the computed comparisons to the standard calibration materials. 5

9 Protector Laboratory Fume Hoods & Enclosures Overview Ducted Hoods vs. Ductless Carbon-Filtered Enclosures Protector, Basic, Fiberglass 30, Demonstration and Canopy Hoods and Protector VS Ventilation Stations require ducting to the outside so that contaminants can be dispersed and diluted above the roofline. Ducting to the outside provides the safest means to ensure that contaminants are removed from the laboratory. Other Labconco enclosures, such as the Protector VS Ventilation Stations with Protector FilterMate Mobile Stations, Paramount Filtered Enclosures, Protector Work Stations and Fume Adsorbers, return filtered exhaust air back to the laboratory. These enclosures rely on specially treated or activated carbon media that treat or adsorb chemical gases including certain organic solvents, ammonia, acids and formaldehyde. Paramount Duet Filtered Enclosures and some models of Protector VS Ventilation Stations with FilterMate use both carbon-based and HEPA filters which can be used with applications that create both gaseous and particulate contaminants. Filtered enclosures provide a practical solution for situations where ducting is not feasible, such as laboratories surrounded by interior walls and located several stories from the roof. Filtered enclosures are appropriate for light duty chemical work in air-starved laboratories where make-up air is unavailable. When placed on mobile stands, they become portable stations that can be shared by several laboratories or easily moved out of the way for storage. Whether or not a carbon-filtered enclosure is the right ventilation product for your application requires consideration of factors such as the time-weighted exposure limits of your materials. Using Labconco s exclusive chemical assessment program, our technical specialists can help you determine the right product for your application. To begin the process, please complete the chemical usage assessment form available at www. labconco.com/chemical-usage.html. In-depth Laboratory Hood System Information Available The preceding discussion on the many fume hood options available provides an overview to the detailed ordering information on specific hoods, enclosures, base cabinets, stands, work surfaces and accessories that follows. For an in-depth generic discussion on various hood selection considerations and choices, Labconco offers the How To Select The Right Laboratory Hood System booklet. Please call or or visit for your free copy of this informative guide. Product Protector Premier Protector XStream Protector XL Benchtop Protector XL HOPEC IV Protector XL Floor-Mounted Protector ClassMate Protector ClassMate HOPEC IV Protector Stainless Steel Radioisotope Protector Stainless Steel Perchloric Acid Protector PVC Perchloric Acid Protector PVC Acid Digestion Basic Fiberglass 30 Protector VS Ventilation Station Applications/ Considerations Broad range for general chemistry Broad range for general chemistry, Energy savings, Enhanced containment Broad range for general chemistry Broad range for general chemistry, Energy savings, ADA Broad range for general chemistry, Large apparatus and processes Instruction, Demonstration Instruction, Demonstration, Energy savings, ADA Low level radiochemistry Perchloric acid Perchloric acid Acid digestion, Hydrofluoric acid Light duty general chemistry, Organic chemistry General chemistry Light duty chemistry/weighing, Instruction, Organics Demonstration Low-toxicity, Instruction, Demonstration Canopy Heat, Steam, Odors, Non-toxic materials When located in a clean room, the Paramount Duet Filtered Enclosure, which uses both carbon-based and HEPA filter cells, provides a safe, self-contained work station for removal of chemical fumes or vapors while exhausting ISO Class 5 (formerly Class 100) air. Protector Work Station Histology, Pathology, Tissue grossing, Staining, Organics 6

10 Protector Laboratory Fume Hoods & Enclosures Selection Guide Chemical Fume Hoods and Enclosures Selection Guide Liner Material Nominal Interior Blower Auxiliary-Air Sash Pages Exterior Widths Depths Options Configurations One-piece 4', 5', 6', 8' 23.5" Remote, Built-in Available on Vertical-rising* molded fiberglass some models Fiberglass-reinforced 4', 5', 6', 8' 27.3" Remote Vertical-rising* composite panel Fiberglass-reinforced 4', 5', 6', 8', 24", 30", 36" Remote Available on Vertical-rising* 24-29, composite panel 10', 12', 16' some models Fiberglass-reinforced 4', 5', 6', 8' 29.5" Remote Combination 30-31, 39 composite panel Fiberglass-reinforced 4', 5', 6', 8', 30", 36", 48" Remote Vertical-rising, 32-36, composite panel 10', 12', 16' horizontal-sliding Tempered safety glass 4', 5', 6' 25.75" Remote Vertical-rising Epoxy-coated steel Tempered safety glass 4', 5', 6' 26.25" Remote Combination Epoxy-coated steel Type 304 4', 5', 6', 8' 23.5" Dedicated remote Vertical-rising stainless steel Type 316 4', 5', 6', 8' 23.5" Dedicated remote Vertical-rising stainless steel PVC 4', 6', 8' 30.0" Dedicated remote Vertical-rising PVC 4', 6', 8' 30.0" Dedicated remote Vertical-rising Epoxy-coated steel 4', 6' 18.44" Remote, Built-in Vertical-rising One-piece 30" 22.67" Remote, Built-in Vertical-rising molded fiberglass Tempered safety glass 2', 3', 4' 20.5" Remote Pivoting with Epoxy-coated aluminum permanent 10.25" opening Tempered safety glass 3' 25.0" Built-in Vertical-rising 83 Epoxy-coated steel Epoxy-coated steel 4', 6' 30.0" Remote Not applicable 84 Type 304 stainless steel, 4' 13.75" Remote, Built-in Pivoting with phenolic/melamine- permanent laminated hardboard 10" opening * Contact Labconco at or for ordering information on hoods with combination sashes. 7

11 Protector Laboratory Fume Hoods & Enclosures Selection Guide Carbon-Filtered Enclosures Selection Guide Product Filter Type(s) Applications Carbon Liner Nominal Interior Pages Filter Materials Exterior Depth Capacity Widths Paramount Carbon-Based Organic Organic chemistry, 52 lbs. Tempered 3', 6' 24.25" 68-71, Filtered Enclosure/ Histology & cytology, safety glass, 74-75, Paramount Duet Solvent cleaning, Epoxy-coated Filtered Enclosure Welding & gluing aluminum & steel Carbon-Based Acid Gases Carbon-Based Ammonia Carbon-Based Formaldehyde Acid pouring & mixing Photoengraving, Plastics production Endoscopy instrument cleaning, Pathology Paramount Duet Carbon-Based/HEPA Clean room, Critical 52 lbs. Tempered 3', 6' 24.25" 72-75, Filtered environments, safety glass, Enclosure Combination dry & Epoxy-coated liquid chemicals, aluminum Weighing chemical & steel powders, Pathology, Soldering, Solvent cleaning Protector VS Carbon-Based Organic Histology/cytology 26 lbs. Tempered 2', 3', 4' 20.5" Ventilation Station Soldering, Solvent safety glass, With Protector cleaning, Welding & Epoxy-coated FilterMate gluing aluminum Mobile Station Carbon-Based Acid Gases Acid pouring & mixing Carbon-Based Ammonia Photoengraving, Plastics production Carbon-Based Endoscopy instrument Formaldehyde cleaning, Pathology Carbon-Based/HEPA Clean room, Critical environments, Combination dry & liquid chemicals, Non-hazardous microbes with trace chemicals, Pathology, Soldering, Solvent cleaning Protector Carbon-Based Histology & cytology 18 lbs. Type 304 3' 13.75" Work Station Xylene/Toluene stainless steel, Phenolic/melamine laminated hardboard Carbon-Based Formaldehyde Pathology Fume Adsorber/ Carbon-Based Histology & cytology 6 lbs./12 lbs. Acrylic, 2', 4' 11.25" 85 Fume Adsorber-2 Epoxy-coated steel 8

12 Protector Laboratory Fume Hoods & Enclosures Applicable Standards Key aspects of standards and codes as they relate to laboratory ventilation are summarized below. Federal Register 29 CFR Part 1910 Occupational exposure to hazardous chemicals in laboratories National Research Council Recommendations Concerning Chemical Hygiene in Laboratories (Nonmandatory) from Prudent Practices. Fume hoods should have a continuous monitoring device. Face velocities should be between linear feet per minute (lfpm). Average 2.5 linear feet of hood space per person. Occupational Safety & Health Administration U.S. Department of Labor 200 Constitution Avenue, NW Washington, DC (800) Industrial Ventilation-ACGIH Fume hood face velocities between lfpm. Maximum of 125 lfpm for radioisotope hoods. Duct velocities of fpm for vapors, gases and smoke. Stack discharge height x building height. Well designed fume hood containment, loss <0.10 ppm. Industrial Ventilation: A Manual of Recommended Practice 23rd Edition, 1998 American Conference of Governmental Industrial Hygienists 1330 Kemper Meadow Drive Cincinnati, OH (513) ASHRAE Method of Testing Performance of Laboratory Fume Hoods (ANSI Approved) Evaluates fume hood s containment characteristics Three part test: Smoke generation, face velocity profile, tracer gas 4 liters per minute. Rated As Manufactured (AM), As Installed (AI) and As Used (AU). American Society of Heating, Refrigerating and Air-Conditioning Engineers 1791 Tullie Circle NE Atlanta, GA (404) ANSI Z Standard Laboratory Ventilation Covers entire laboratory ventilation system. Vertical stack fpm. New and remodeled hoods shall have a monitoring device. Ductless hoods should only be used with nonhazardous materials. American Industrial Hygiene Association 2700 Prosperity Avenue, Suite 250 Fairfax, VA (703) SEFA Laboratory Fume Hoods Recommended Practices Fume hood face velocities based on toxicity levels of chemicals. Class A materials of extreme toxicity 125 to 150 fpm. Class B standard lab chemicals 80 to 100 fpm. Class C materials of low toxicity 75 to 80 fpm. Test method face velocity profile and smoke generation. Scientific Equipment & Furniture Association 1205 Franklin Avenue Suite 320 Garden City, NY (516) NFPA 45: Standard on Fire Protection for Laboratories Using Chemicals, 2000 Edition Laboratory hoods should not be relied on for explosion protection. Fume hood exhaust air should not be recirculated. Services should be external to the hood. Canopy hoods only for non-hazardous applications. Materials of construction should have flame spread of 25 or less. National Fire Protection Association 1 Batterymarch Park P.O. Box 9101 Quincy, MA (800) ASTM E84-01 Standard Test Method for Surface Burning Characteristics of Building Materials Determines the relative burning behavior of the material by observing the flame spread along the specimen. Measures flame spread and smoke development. Material is exposed to flaming fire for 10 minutes and the results measured and recorded. Results are compared to the indexes of mineral fiber cement board (flame spread and smoke development of zero) and red oak flooring (smoke development of 100). ASTM International 100 Barr Harbor Drive P.O. Box C700 West Conshohocken, PA (610) UL 1805 Standard for Laboratory Hoods and Cabinets Hood interior constructed of nonflammable, corrosion and chemical-resistant materials. Counterbalanced sash of non-shattering material. Shielded by-pass opening. Dished work surface to contain spills. No air recirculation. Integral blower wheel of nonsparking materials. Externally-mounted electrical receptacles, light fixtures and service fixture controls. No indication of reverse flow or backflow when tested with sash at full, 2/3 and 1/3 open positions at flow rate recommended by the manufacturer. UL (formerly ) Electrical Equipment for Laboratory Use Specifies the general safety requirements for electrical equipment Based on International Electrotechnical Commission (IEC) Publication with differences noted for U.S. use. Tests for protection against electrical shock, mechanical hazards, spread of fire, radiation, liberated gases, explosion and implosion. Tests for resistance to shock, vibration, impact, heat, moisture and liquids. Underwriters Laboratories Inc. 333 Pfingsten Road Northbrook, IL (847) CAN/CSA Standard C22.2 No Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Specifies general safety requirements for electrical equipment Design and methods of construction should provide adequate protection to the operator and the surrounding area against shock or burn, mechanical hazards, excessive temperature, spread of fire from the equipment, gas liberation, explosion or implosion. Canadian Standards Association 5060 Spectrum Way Mississauga, Ontario L4W 5N6 CANADA (800) CE Marking Established in 1993 to standardize the European Community s electrical directives into a single set of regulations. Indicates an electrical apparatus conforms to all safety and other directives/specifications presently required by the Council of European Communities. Electrical safety. Electromagnetic emissions testing interference signals being output by the product. Electromagnetic immunity testing the product does not respond to outside electromagnetic interference signals. European Union European Union Delegation of the European Commission to the United States 2300 M Street, NW Washington, DC Telephone: (202)

13 Protector Premier Laboratory Hood is shown with SpillStopper Work Surface and Protector Solvent Storage Cabinet

14 Protector Premier Laboratory Hoods Features & Benefits Protector Premier Laboratory Hoods incorporate a sleek exterior with a molded one-piece fiberglass liner, the signature feature of Labconco s leading line of fume hoods since The one-piece liner of specially-formulated, fiberglass-reinforced polyester offers corrosion and fire resistance and easy clean up. Protector Premier Laboratory Hoods are offered in 4', 5', 6' and 8' widths so their dimensions exactly match standard laboratory casework or accessory Protector Base Cabinets and Stands. Choose from hoods designed to be used with a remotely-located blower or hoods that include a built-in blower. Models with built-in blower are available. Quiet built-in blower is belt-driven with molded thermoplastic housing and coated aluminum impeller that is non-sparking and corrosion-resistant. Available with explosion-proof or standard motor. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. By-pass airflow design ensures stable face velocities that meet or exceed established standards. Corrosion-resistant, molded fiberglass exhaust connection(s) on models for use with remote blowers. Pre-set baffle provides a uniform face velocity pattern across the sash opening of the hood. Large 28" sash opening offers superior viewing. When fully open, the sash does not extend above the hood. Fluorescent lighting illuminates the interior. The high efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. Explosion-proof models are supplied with an incandescent light fixture. Vertical-rising tempered safety glass sash is antiracking for smooth operation. Contact Labconco for ordering information on horizontalsliding or combination sashes. Service access panels allow accessibility to plumbing from the front of the hood. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are preplumbed on fixtured models. Each hood is factory prepared for up to eight service fixtures (four on each side). ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and CAN/CSA C22.2 No Ergonomic air foil allows air to sweep the work surface for maximum containment. Clean-Sweep* airflow openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. Durable and attractive exterior is glacier white, dry powder epoxy-coated steel. CE mark. All 230 volt, 50 Hz models conform to the CE (European Community) requirements for electrical safety and electromagnetic compatibility. One-piece molded fiberglass liner gives superior corrosion and chemical resistance, durability and light reflectivity. Its smooth, radiused corners make cleaning easy. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factorywired on 115 volt, 60 Hz fixtured models. Each hood is factory-prepared for up to four electrical duplexes and an airflow monitor. Explosionproof models are furnished without switches, electrical receptacle and wiring as these must conform to varying local codes. Performance tested to ASHRAE Exclusive Feature *U.S. Patent No. 6,461,233 pending 11

15 Protector Premier Laboratory Hoods for use with remote blower One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side (115 volt models) All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Work Surface. See pages Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Distillation Grid Kits. See page 110. Sash Stop Kits. See page 108. Snuffer Fire Extinguishers. See page 110. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. Auxiliary-Air Kits. See page 110. Protector Premier Laboratory Hood is shown with SpillStopper Work Surface , Protector Solvent Storage Cabinet and Acid Storage Cabinet Blower, ductwork, work surface and base cabinets must be ordered separately. All models feature: By-pass airflow design Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings Glacier white, dry powder epoxy-coated steel exterior One-piece molded fiberglass liner and pre-set baffle(s) with flame spread less than 25 per ASTM E-84 3/16" thick tempered safety glass vertical-rising sash(es) with epoxycoated sash handle Removable front and side panels and front access panels for access to plumbing and electrical wiring Pre-wired T8 fluorescent lighting, light and blower switches Molded fiberglass 12.81" ID exhaust connection(s) Exclusive Feature All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 CE Conformity Marking (230 volt models) Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. With Sash Full Open (28") Nominal Total Exhaust CFM and Static Pressure Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " With Sash 60% Open (18")** Nominal Total Exhaust CFM and Static Pressure Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " * U.S. Patent No. 6,461,233 pending ** Sash stop required Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 12

16 Ordering Information Protector Premier Laboratory Hoods for use with remote blower Nominal Catalog Electrical 12.81" ID Fluorescent Service Electrical Shipping Width Number Requirements Exhaust Collar(s) Sash Lamps Fixtures Duplex Weight lbs./kg 4 Feet volts, 60 Hz ea. 25 watt None None 327/ volts, 60 Hz ea. 25 watt / * 230 volts, 50 Hz ea. 25 watt None None 327/ * 230 volts, 50 Hz ea. 25 watt 2 None 337/153 5 Feet volts, 60 Hz ea. 32 watt None None 409/ volts, 60 Hz ea. 32 watt / * 230 volts, 50 Hz ea. 32 watt None None 409/ * 230 volts, 50 Hz ea. 32 watt 2 None 419/190 6 Feet volts, 60 Hz ea. 32 watt None None 486/ volts, 60 Hz ea. 32 watt / * 230 volts, 50 Hz ea. 32 watt None None 486/ * 230 volts, 50 Hz ea. 32 watt 2 None 496/225 8 Feet volts, 60 Hz ea. 25 watt / * 230 volts, 50 Hz ea. 25 watt 2 None 675/306 *International electrical configuration 4 Feet 5 Feet 48" 60" 33.20" 28" Sash Opening 59" 32.15" Viewing Height to Work Surface 38.25" Inside 28" Sash Opening 32.15" Viewing Height to Work Surface 50.25" Inside 23.5" 3.2" 6 Feet 8 Feet 37" 72" 96" Side View / All Models (Shown with accessory work surface and base cabinet available for all hood widths. Height can vary.) 28" Sash Opening 62.25" Inside 32.15" Viewing Height to Work Surface 28" Sash Opening 86.25" Inside 32.15" Viewing Height to Work Surface See additional dimensional data on page

17 Protector Premier Laboratory Hoods with built-in blower Protector Premier Laboratory Hood is shown with SpillStopper Work Surface and Protector Solvent Storage Cabinet Ductwork, work surface and base cabinet must be ordered separately. Explosion-proof models feature: Explosion-proof blower and incandescent light fixture (bulb not included). Furnished without switches, electrical receptacle and wiring as these must conform to varying local codes. Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side (115 volt models). All models feature: Built-in belt-driven, corrosion-resistant exhaust blower with adjustable sheave, molded thermoplastic housing and nonsparking, coated aluminum impeller. By-pass airflow design. Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings. Glacier white, dry powder epoxy-coated steel exterior. One-piece molded fiberglass liner and pre-set baffle(s) with flame spread less than 25 per ASTM E-84. 3/16" thick tempered safety glass vertical-rising sash with epoxycoated sash handle. Removable front and side panels and front access panels for access to plumbing and electrical wiring " ID exhaust connection (4' models); 12.81" ID exhaust connection (5' and 6' models). All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 CE Conformity Marking (230 volt models) Standard models feature: Pre-wired T8 fluorescent lighting, light and blower switches. Exclusive Feature All models require (not included): Ductwork. See back pocket. Work Surface. See pages Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Distillation Grid Kits. See page 110. Sash Stop Kits. See page 108. Snuffer Fire Extinguishers. See page 110. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. Built-In Blower Maximum External Static 100 fpm Nominal Hood Ductwork Equivalent Width CFM S.P. Diameter Resistance** 4 Feet " 10" 75 5 Feet " 12" 75 6 Feet " 12" 70 * U.S. Patent No. 6,461,233 ** Equivalent resistance in feet of straight duct pending Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 14

18 Ordering Information Protector Premier Laboratory Hoods with built-in blower Nominal Catalog Built-In Electrical Exhaust EP Incandescent Fluorescent Service Electrical Shipping Width Number Blower Requirements Collar (ID) Light Fixture* Lamps Fixtures Duplex Weight lbs./kg 4 Feet /3 HP, Std. 115 volts, 60 Hz 10.81" 2 ea. 25 watt None None 327/ /3 HP, EP 115 volts, 60 Hz 10.81" 1 ea. None None 327/ /3 HP, Std. 115 volts, 60 Hz 10.81" 2 ea. 25 watt / ** 1/2 HP, Std. 230 volts, 50 Hz 10.81" 2 ea. 25 watt None None 327/ ** 1/2 HP, Std. 230 volts, 50 Hz 10.81" 2 ea. 25 watt 2 None 337/153 5 Feet /2 HP, Std. 115 volts, 60 Hz 12.81" 2 ea. 32 watt None None 384/ /2 HP, EP 115 volts, 60 Hz 12.81" 1 ea. None None 384/ /2 HP, Std. 115 volts, 60 Hz 12.81" 2 ea. 32 watt / ** 1/2 HP, Std. 230 volts, 50 Hz 12.81" 2 ea. 32 watt None None 384/ ** 1/2 HP, Std. 230 volts, 50 Hz 12.81" 2 ea. 32 watt 2 None 394/179 6 Feet /2 HP, Std. 115 volts, 60 Hz 12.81" 2 ea. 32 watt None None 461/ /2 HP, EP 115 volts, 60 Hz 12.81" 1 ea. None None 461/ /2 HP, Std. 115 volts, 60 Hz 12.81" 2 ea. 32 watt / ** 1/2 HP, Std. 230 volts, 50 Hz 12.81" 2 ea. 32 watt None None 461/ ** 1/2 HP, Std. 230 volts, 50 Hz 12.81" 2 ea. 32 watt 2 None 471/213 *Bulb not included **International electrical configuration EP = explosion-proof 4 Feet 5 Feet 48" 60" 33.20" 65.63" 28" Sash Opening 32.15" Viewing Height to Work Surface 38.25" Inside 28" Sash Opening 32.15" Viewing Height to Work Surface 50.25" Inside 23.5" 48" 59" 3.2" 6 Feet Side View /All Models (Shown with accessory work surface and base cabinet available 72" for all hood widths. Height can vary.) 37" 28" Sash Opening 62.25" Inside 32.15" Viewing Height to Work Surface See additional dimensional data on page

19 Dimensional Data 4', 5', 6' and 8' Protector Premier Laboratory Hoods for use with remote blower 4.91" 2.27" C B 2.5" dia. Service Fixture Supply Holes 10.53" 4', 5' and 6' Hoods A B C 12.81" ID Exhaust Collar Single Point Internal Junction Box 4' Hood 48" 38.25" 24" 5' Hood 60" 50.25" 30" 6' Hood 72" 62.25" 36" TOP 33.20" Fluorescent Lights 3.00" Front Access Panel (one on each side) 28" Sash Opening 32.15" Viewing Height to Work Surface B A FRONT Service Fixture (one on each side on fixtured models) 115 Volt, 20 Amp Duplex Electrical Receptacle (one on fixtured models) 16.44" 2.00" 23.50" Sash Frame to Baffle SIDE 48" 59" 2.5" dia. Service Fixture Supply Holes 4.91" 24" 86.25" 48" 10.53" 8' Hoods 2.27" 12.81" ID Exhaust Collars 33.20" Single Point Internal Junction Box TOP C Front Fixture Panel (one on each side) Service Fixture (one on each side on fixtured models) Fluorescent Lights 33.20" 3.00" 48" 59" 28" Sash Opening 86.25" 32.15" Viewing Height to Work Surface 96" FRONT 115 Volt, 20 Amp Duplex Electrical Receptacle (one on fixtured models) 16.44" 2.00" 23.50" Sash Frame to Baffle SIDE Contact Labconco at or for detailed AutoCAD drawings. 16 AutoCAD is a registered trademark of AutoDesk.

20 Dimensional Data 4', 5' and 6' Protector Premier Laboratory Hoods with built-in blower 11.53" Exhaust Duct C 15.69" Centerline Hood 2.27" 4.91" Single Point Internal Junction Box A B C 4' Hood 48" 38.25" 10.81" ID 5' Hood 60" 50.25" 12.81" ID 6' Hood 72" 62.25" 12.81" ID TOP A 33.20" Fluorescent Lights (Standard Models) Front Access Panel (one on each side) 28" Sash Opening B 32.15" Optional Airflow Monitor Location Service Fixture (one on each side on fixtured models) 115 Volt, 20 Amp Duplex Electrical Receptacle (one on fixtured models) Explosion-proof Light Fixture (Explosion-proof models) 16.44" 2.00" 23.50" Sash Frame to Baffle 48.00" 59.00" 65.63" FRONT SIDE Contact Labconco at or for detailed AutoCAD drawings. 17

21 Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Standard Storage Cabinet

22 Protector XStream Laboratory Hoods Patented * Features & Benefits With its energy savings potential and unsurpassed containment, the patented Protector XStream is truly a high performance hood. Features, such as an upper dilution air supply, containmentenhancing sash handle, rear downflow dual baffle system and air foil, work together to decrease turbulence and enhance airflow. When operated at OSHA-approved 60 fpm face velocity, Protector XStream Laboratory Hoods provide an excellent economic payback when compared to traditional hoods running at 80 or 100 fpm. These panel-lined hoods are available in 4', 5', 6' and 8' widths. They are designed to be used with a remotely-located blower. Using the concepts of fluid dynamics, Labconco researchers engineered the Protector XStream Laboratory Hood with horizontal laminar airflow to overcome the tendencies for turbulence. The innovative and aerodynamic designs of the sash handle, air foil, upper dilution air supply and rear downflow baffle work in concert to produce horizontal airflow patterns that significantly reduce concentrations of chemical contaminants throughout the work area, particularly near the face of the hood, the operator s breathing zone and at the work surface. Depending on sash position, tendencies for air turbulence, vortexing and the roll frequently observed during traditional fume hood smoke tests are virtually eliminated. Traditional Hood Design Smoke tests on traditional hoods show the tendency for contaminants generated in the interior to roll forward producing high concentrations of contaminants behind the sash in close proximity to the user s breathing zone. Upper Dilution Air Supply The sash interior is constantly bathed with room air from the dilution supply above the work area to eliminate chemical fumes along the sash plane, near the critical breathing zone. Five to ten percent of the required air volume is introduced through the dilution air supply to ensure maximum containment and greatest worker protection. No additional blowers are required. Rear Downflow Dual Baffle System When the sash is open to the 18" working height or 28" loading height, the slots in the primary baffle direct inflow air in non-turbulent streams from the hood face into the baffle in a single pass. The secondary baffle, located between the primary baffle and the back wall, counteracts the upward air streams that create roll in traditional hoods by forcing the air movement downward before exhausting. No mechanical components are used. In contrast, smoke tests on Protector XStream Hoods show contaminants removed in a single pass and a remarkable lack of turbulence. Horizontal laminar air flowing toward the baffle forces contaminants to the rear interior, away from the user. The upper dilution air supply sweeps the upper interior to eliminate stagnant pockets of air and to prevent contaminants from concentrating in the area behind the sash. Upper Dilution Air Supply Containment-Enhancing Sash Handle Secondary Baffle Primary Baffle Ergonomic Air Foil with Clean-Sweep Openings Protector XStream Hood Design Smoke released inside the hood moves in a horizontal stream to the primary baffle slots. Containment-Enhancing Sash Handle The revolutionary sash handle design includes a perforated air passage directly atop the handle to bleed air into the hood chamber and direct chemical fume concentrations away from the Baffle user s breathing zone. The large radiused sash handle sweeps airflow into the hood with minimal turbulence. Its ergonomic design is comfortable to the touch and easy to grasp to raise and lower the sash. Exclusive Feature * U.S. Patent No. 6,461,233 At left: Arrows show how air enters under the sash handle and through slots directly atop the handle. 19

23 Protector XStream Laboratory Hoods Additional Features & Benefits Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. Fluorescent lighting illuminates the interior. The high efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. Contact Labconco for ordering information on explosionproof lighting. Durable and attractive exterior is glacier white, dry powder epoxycoated steel. Large 28" sash opening offers superior viewing. When fully open, the sash does not extend above the hood. Vertical-rising tempered safety glass sash is anti-racking for smooth operation. Chemical-resistant, fiberglassreinforced composite panel liner surpasses all national codes for flame spread and has a bright white surface for excellent light reflectivity. Service access panels allow accessibility to plumbing from the front and inside of the hood. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed on fixtured models. Each hood is factory prepared for up to eight service fixtures (four on each side). Modified by-pass airflow design ensures stable face velocities that meet or exceed established standards. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and CAN/CSA C22.2 No Sash stop located at 18" working height maximizes energy conservation by preventing the sash from being raised further unless manually released. Ergonomic air foil allows air to sweep the work surface for maximum containment. Clean-Sweep* airflow openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factory-wired on 115 volt, 60 Hz fixtured models. Each hood is factory-prepared for up to four electrical duplexes and an airflow monitor. Performance tested to ASHRAE CE mark. All 230 volt, 50 Hz models conform to the CE (European Community) requirements for electrical safety and electromagnetic compatability. Exclusive Feature * U.S. Patent No. 6,461,233 pending 20

24 Protector XStream Laboratory Hoods All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 CE Conformity Marking (230 volt models) Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side. Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Standard Storage Cabinet Blower, ductwork, work surface and base cabinets must be ordered separately. All models feature: Modified by-pass airflow design. Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings. Upper Dilution Air Supply.* Glacier white, dry powder epoxy-coated steel exterior. Chemical-resistant, fiberglass-reinforced, composite panel liner and pre-set Rear Downflow Dual Baffle System* with flame spread less than 25 per ASTM E-84. 3/16" thick tempered safety glass vertical-rising sash with epoxy-coated aluminum sash handle with large radius and perforations.* Removable front and side panels and front and interior service access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, ADAcompliant light and blower switches for 115 volt, 60 Hz operation. Sash stop located at 18" sash opening position. Epoxy-coated stainless steel, 12.81" ID exhaust connection(s). Contact Labconco at or for ordering information on explosion-proof lighting and other sash configurations and for blower sizing assistance. All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Work Surface. See pages Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Distillation Grid Kits. See page 110. Sash Stop Kits. See page 108. Snuffer Fire Extinguishers. See page 110. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. * U.S. Patent No. 6,461,233 pending Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. Exclusive Feature 21

25 Ordering Information Protector XStream Laboratory Hoods ASHRAE tests show less than 0.05 ppm leak rate when tested at 4.0 lpm; at OSHA-approved 60, 80, and 100 fpm face velocity and sash positions of 18" and 28". To ensure performance at 60 fpm, Labconco engineers challenged the Protector XStream Hood at less than ideal conditions such as 30 fpm cross drafts, modified ASHRAE test procedures and average face velocities lower than 60 fpm. Contact Labconco for a technical paper with complete ASHRAE test data. Total Exhaust CFM and Static 18" Sash Opening (60% open) Nominal CFM Savings at Total Average Annual Dollar Width 100 fpm s.p. 80 fpm s.p. 60 fpm s.p. 60 fpm vs. 100 fpm Savings at 60 fpm vs. 100 fpm* 4 feet " " " 190 $760 5 feet " " " 240 $960 6 feet " " " 300 $ feet " " " 420 $1680 Total Exhaust CFM and Static 28" Sash Opening (100% open) Nominal CFM Savings at Total Average Annual Dollar Width 100 fpm s.p. 80 fpm s.p. 60 fpm s.p. 60 fpm vs. 100 fpm Savings at 60 fpm vs. 100 fpm* 4 feet " " " 290 $ feet " " " 380 $ feet " " " 470 $ feet " " " 660 $2640 *Based on average annual dollars per CFM usage of $4.00; fume hood operating 24 hours a day and 5 days per week (6240 hours per year). Catalog Nominal Electrical Exterior Interior Fluorescent Service Electrical Exhaust Shipping Number Width Requirements Depth Working Depth Lamps Fixtures Duplex Collar(s) Wt. lbs./kg feet 115 volts, 60 Hz 39.20" 27.3" (2) 25 watt None None 12.81" ID 400/ feet 115 volts, 60 Hz 39.20" 27.3" (2) 25 watt " ID 400/ ** 4 feet 230 volts, 50 Hz 39.20" 27.3" (2) 25 watt None None 12.81" ID 400/ ** 4 feet 230 volts, 50 Hz 39.20" 27.3" (2) 25 watt 2 None 12.81" ID 400/ feet 115 volts, 60 Hz 39.20" 27.3" (2) 32 watt None None 12.81" ID 460/ feet 115 volts, 60 Hz 39.20" 27.3" (2) 32 watt " ID 460/ ** 5 feet 230 volts, 50 Hz 39.20" 27.3" (2) 32 watt None None 12.81" ID 460/ ** 5 feet 230 volts, 50 Hz 39.20" 27.3" (2) 32 watt 2 None 12.81" ID 460/ feet 115 volts, 60 Hz 39.20" 27.3" (2) 32 watt None None 12.81" ID 520/ feet 115 volts, 60 Hz 39.20" 27.3" (2) 32 watt " ID 520/ ** 6 feet 230 volts, 50 Hz 39.20" 27.3" (2) 32 watt None None 12.81" ID 520/ ** 6 feet 230 volts, 50 Hz 39.20" 27.3" (2) 32 watt 2 None 12.81" ID 520/ feet 115 volts, 60 Hz 39.20" 27.3" (4) 25 watt None None (2) 12.81" ID 700/ feet 115 volts, 60 Hz 39.20" 27.3" (4) 25 watt 2 1 (2) 12.81" ID 700/ ** 8 feet 230 volts, 50 Hz 39.20" 27.3" (4) 25 watt None None (2) 12.81" ID 700/ ** 8 feet 230 volts, 50 Hz 39.20" 27.3" (4) 25 watt 2 None (2) 12.81" ID 700/318 **International electrical configuration 4 Feet Series 5 Feet Series 6 Feet Series 8 Feet Series Side View / All Models 48" 60" 72" 96" 39.20" 28" Sash Opening 32.15" Viewing Height to Work Surface 38.25" Inside 28" Sash Opening 32.15" Viewing Height to Work Surface 50.25" Inside 28" Sash Opening 62.25" Inside 32.15" Viewing Height to Work Surface 28" Sash Opening 86.25" Inside 32.15" Viewing Height to Work Surface 27.34" 59" 3.2" (Side view shown with accessory work surface and base cabinet available for all hood widths. Height can vary.) 37" 22

26 Dimensional Data Protector XStream Laboratory Hoods 4.91" 2.27" C B 9.41" 2.5" dia. Service Fixture Supply Holes A B C 4' Hood 48.00" 38.25" 24.00" 12.81" ID Exhaust Collar Single Point Internal Junction Box 5' Hood 60.00" 50.25" 30.00" 6' Hood 72.00" 62.25" 36.00" 8' Hood 96.00" 86.25" 24.00" TOP 4', 5', 6' 4.91" 2.27" 2.5" dia. Service Fixture Supply Holes B C 48.00" 9.41" 12.81" ID Exhaust Collars Single Point Internal Junction Box A TOP 8' Fluorescent Lamps Front Access Panel (one on each side) Optional Airflow Monitor Location Upp Diluti Air Supp Upper Dilution Air Supply 59.00" 6.81" 24.00" Sash Frame to Baffle Upper Baffle 8.62" 28.00" Full Sash Opening 18.00" Sash Stop Opening 32.15" Viewing Height to Work Surface B Interior Width Service Fixture (one on each side on fixtured models) Light and Blower Switches 115 Volt, 20 Amp Duplex Electrical Receptacle (one on fixtured models) xture ach side d models) Blower Amp ectrical e xtured 16.44" 2.00" Interior Access Panel 27.34" Sash Frame to Baffle 39.18" 48.00" Interior Height 1.25" Secondary Baffle Primary Baffle, 5 Slope FRONT SIDE Contact Labconco at or for detailed AutoCAD drawings. 23

27 Protector XL Benchtop Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Solvent Storage Cabinet

28 Protector XL Laboratory Hoods Features & Benefits Protector XL Benchtop Laboratory Hoods have chemical-resistant panel liners that offer superior design flexibility. They are supplied in widths from 4 to 16 feet and three depths to meet a variety of installation and application requirements. Protector XL HOPEC IV Laboratory Hoods have unique features that address safety, ADA and energy conservation concerns. They are offered in 4', 5', 6'and 8' widths. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL Standard / , UL 1805 and CAN/CSA C22.2 No Large sash openings offer superior viewing. Benchtop hoods feature 28" opening heights and 32.15" viewing heights. HOPEC IV hoods have 30" opening and 37" viewing heights. Tempered safety glass sashes are anti-racking for smooth operation. Benchtop hoods have vertical-rising sashes. HOPEC IV hoods include combination sashes with both vertical and horizontal movement. Interior working dimensions are offered in standard and larger depths. Working depths include 24", 30", and 36" for benchtop hoods; and 29.50" for HOPEC IV hoods. Fluorescent lighting illuminates the interior. The high-efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. Contact Labconco for ordering information on explosionproof lighting. Service access panels allow easy accessibility to plumbing from the front and inside of the hood. Chemical-resistant, fiberglassreinforced composite panel liner surpasses all national codes for flame spread and has a bright white surface for excellent light reflectivity. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factory-wired on fixtured models. Each hood is factoryprepared for up to four electrical duplexes and an airflow monitor. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed on fixtured models. Each hood is factory prepared for up to eight service fixtures (four on each side). Ergonomic air foil allows air to sweep the work surface for maximum containment. Benchtop models feature patented* Clean-Sweep airflow openings that pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. Baffle provides a uniform face velocity pattern across the sash opening of the hood. Benchtop hoods have pre-set baffles. HOPEC IV hoods come standard with internally adjustable baffles. Durable and attractive exterior is glacier white, dry powder epoxycoated steel. By-pass airflow design ensures relatively stable face velocities. Performance tested to ASHRAE Exclusive Feature *U.S. Patent No. 6,461,233 25

29 Protector XL Benchtop Laboratory Hoods All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Work Surface. See page Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Distillation Grid Kits. See page 110. Sash Stop Kits. See page 108. Snuffer Fire Extinguishers. See page 110. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. Auxiliary-Air Kits. See page 110. Protector XL Benchtop Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Solvent Storage Cabinet Blower, ductwork, work surface and base cabinets must be ordered separately. Contact Labconco at or for ordering information on adjustable baffles, explosion-proof lighting, tissue screens and other sash configurations and for blower sizing assistance. 26 All models feature: By-pass airflow design. Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings. Glacier white, dry powder epoxy-coated steel exterior. Chemical-resistant molded composite panel liner and pre-set baffle(s) with flame spread less than 25 per ASTM E-84. 3/16" thick tempered safety glass vertical-rising sash(es) with epoxycoated aluminum sash handle(s). Removable front and side panels and front and interior service access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light and blower switches for 115 volt, 60 Hz operation. Epoxy-coated stainless steel, 12.81" ID exhaust connection(s). All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side. With Sash Full Open (28") Nominal Total Exhaust CFM and Static Pressure Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " 10 Feet " " 12 Feet " " 16 Feet " " With Sash 60% Open (18")** Nominal Total Exhaust CFM and Static Pressure Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " 10 Feet " " 12 Feet " " 16 Feet " " Exclusive Feature Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. *U.S. Patent No. 6,461,233 **Sash stop required

30 Ordering Information 4', 5' and 6' Protector XL Benchtop Laboratory Hoods Nominal Catalog Exterior Interior 12.81" ID Fluorescent Service Electrical Shipping Width Number Depth (A) Depth (B) Exhaust Collar Sash Lamps Fixtures Duplex Weight lbs./kg 4 Feet " 30" ea. 25 watt None None 400/ " 30" ea. 25 watt / " 36" ea. 25 watt None None 420/ " 36" ea. 25 watt / " 24" ea. 25 watt None None 380/ " 24" ea. 25 watt /177 5 Feet " 30" ea. 32 watt None None 460/ " 30" ea. 32 watt / " 36" ea. 32 watt None None 483/ " 36" ea. 32 watt / " 24" ea. 32 watt None None 437/ " 24" ea. 32 watt /203 6 Feet " 30" ea. 32 watt None None 550/ " 30" ea. 32 watt / " 36" ea. 32 watt None None 578/ " 36" ea. 32 watt / " 24" ea. 32 watt None None 523/ " 24" ea. 32 watt /242 4 Feet Series 5 Feet Series 48" 60" A 28" Sash Opening 32.15" Viewing Height to Work Surface 38.25" Inside 28" Sash Opening 32.15" Viewing Height to Work Surface 50.25" Inside B 59" 3.2" 6 Feet Series 72" 37" Side View /All Models (Shown with accessory work surface and base cabinet available for all hood widths. Height can vary.) 28" Sash Opening 62.25" Inside 32.15" Viewing Height to Work Surface See additional dimensional data on page

31 Ordering Information 8' and 10' Protector XL Benchtop Laboratory Hoods Nominal Catalog Exterior Interior 12.81" ID Fluorescent Service Electrical Shipping Width Number Depth (A) Depth (B) Exhaust Collars Sashes Lamps Fixtures Duplex Weight lbs./kg 8 Feet " 30" ea. 25 watt None None 800/ " 30" ea. 25 watt / " 36" ea. 25 watt None None 840/ " 36" ea. 25 watt / " 24" ea. 25 watt None None 760/ " 24" ea. 25 watt / Feet " 30" ea. 32 watt None None 1000/ " 30" ea. 32 watt / " 36" ea. 32 watt None None 1050/ " 36" ea. 32 watt / " 24" ea. 32 watt None None 950/ " 24" ea. 32 watt /435 8 Feet Series 96" A 28" Sash Opening 86.25" Inside 32.15" Viewing Height to Work Surface B 59" 3.2" 10 Feet Series 37" 120 " Side View /All Models (Shown with accessory work surface and base cabinet available for all hood widths. Height can vary.) " Inside 32.15" Viewing Height to Work Surface 28" Sash Opening See additional dimensional data on page

32 Ordering Information 12' and 16' Protector XL Benchtop Laboratory Hoods Nominal Catalog Exterior Interior 12.81" ID Fluorescent Service Electrical Shipping Width Number Depth (A) Depth (B) Exhaust Collars Sashes Lamps Fixtures Duplex Weight lbs./kg 12 Feet " 30" ea. 32 watt None None 1200/ " 30" ea. 32 watt / " 36" ea. 32 watt None None 1260/ " 36" ea. 32 watt / " 24" ea. 32 watt None None 1140/ " 24" ea. 32 watt / Feet " 30" ea. 25 watt None None 1600/ " 30" ea. 25 watt / " 36" ea. 25 watt None None 1680/ " 36" ea. 25 watt / " 24" ea. 25 watt None None 1520/ " 24" ea. 25 watt / Feet Series 144" A 32.15" Viewing Height to Work Surface " Inside 28" Sash Opening B 59" 3.2" Side View /All Models (Shown with accessory work surface and base cabinet available for all hood widths. Height can vary.) 37" 16 Feet Series 192" 32.15" Viewing Height to Work Surface " Inside 28" Sash Opening See additional dimensional data on page

33 Protector XL HOPEC IV Laboratory Hoods Pre-wired T8 fluorescent lighting, digital airflow monitor and light switch for 115 volt, 60 Hz operation. Epoxy-coated stainless steel, 8.69" ID exhaust connection(s). All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Work Surface. See pages Base Cabinet or Stand. See pages Protector XL HOPEC IV Laboratory Hood is shown with SpillStopper Work Surface and Protector Standard Storage Cabinets and Blower, ductwork, work surface and base cabinets must be ordered separately. All models feature: Hand operated, positive energy control design (HOPEC). Combination horizontal-sliding/verticalrising sashes* allow the operator to use the hood with sashes half open either horizontally or vertically. Sash stop located at the vertical-rising sash closed position encourages use of the horizontal-sliding sashes. Sash stop located at the vertical-rising sash half-open and fully closed positions along with a sash enclosure at the top of the hood that blocks the upper by-pass reducing the amount of air exhausted. Stationary glass viewing panel, provides sash viewing height of 37", to permit the hood to be mounted in sitting or standing position and still maintain the same visual accessibility. Meet requirements of Americans with Disabilities Act (ADA), OSHA Laboratory Standards, and other ergonomic concerns. Chemical-resistant molded composite panel liner and adjustable baffle(s) with flame spread less than 25 per ASTM E-84. Glacier white, dry powder epoxy-coated steel exterior. Epoxy-coated steel sash enclosure on top of hood for preventing laboratory exposure to contaminated interior sash surfaces. By-pass airflow through air foil with Clean-Sweep** openings. Ergonomic, highly-visible yellow air foil with low profile spill trough that requires no cabinet overhang and recessed sash track for user comfort and enhanced airflow " exterior depth (29.50" interior depth). Tissue screen located behind baffle. 1/4" thick tempered safety glass sashes framed with epoxy-coated steel and clear PVC trim. Removable front and side panels and front and interior service access panels for access to plumbing and electrical wiring. Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Snuffer Fire Extinguishers. See page 110. Ceiling Enclosure and Rear Panel Kits. See page 109. Nominal Total Exhaust CFM and Static Pressure Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " Contact Labconco at or for ordering information on explosion-proof lighting and distillation grids and for blower sizing assistance. Exclusive Feature * 4' models have single vertical-rising sash, epoxy-coated aluminum sash handle, opening height of 30" and viewing height of 37". ** U.S. Patent No. 6,461,233 with sashes 50% open 30

34 Ordering Information 4', 5', 6' and 8' Protector XL HOPEC IV Laboratory Hoods Nominal Catalog 8.69" ID Fluorescent Service Electrical Shipping Width Number Exhaust Collar(s) Lamps Fixtures Duplexes Weight lbs./kg 4 Feet ea. 25 watt None None 485/220 5 Feet ea. 32 watt None None 570/259 6 Feet ea. 32 watt None None 680/308 8 Feet ea. 25 watt None None 975/442 4 Feet Feet " 60" 1.37" 39.20" 6" Glass Viewing Panel Glass Viewing Panel 6" 37" Viewing Height to Work Surface 38.25" 50.25" 37" Viewing Height to Work Surface 1.25" 29.50" Sash Frame to Baffle 59" 1.50" 33" ADA Side View 4', 5', 6', 8' (Shown with accessory work surface and base cabinet available for all hood widths. Height can vary.) 37" Standard 6 Feet Feet " 96" Glass Viewing Panel 62.25" 37" Viewing Height to Work Surface 6" 37" Viewing Height to Work Surface Glass Viewing Panel 86.25" 6" See additional dimensional data on page

35 Protector XL Floor-Mounted Laboratory Hood Inset: Protector XL Floor-Mounted Laboratory Hood

36 Protector XL Floor-Mounted Laboratory Hoods Features & Benefits Protector XL Floor-Mounted Laboratory Hoods accommodate laboratory procedures that require cumbersome equipment or maximum work area. Applications requiring distillation racks, extraction apparatus or large drums and carboys benefit from the increased height these hoods provide. Protector XL Floor-Mounted Laboratory Hoods are supplied in three depths and several widths up to 16 feet. Depending on the model, these hoods have verticalrising or horizontal-sliding sashes. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and CAN/CSA C22.2 No Durable and attractive exterior is glacier white, dry powder epoxycoated steel. Tempered safety glass sashes are anti-racking for smooth operation. Hoods feature either vertical-rising or horizontal-sliding sashes depending on hood model. Adjustable baffles provide a uniform face velocity pattern across the sash opening of the hood. Fluorescent lighting illuminates the interior. The high-efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. Contact Labconco for ordering information on explosionproof lighting. Large sash openings offer superior viewing. Hoods have 68.15" viewing heights. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factory-wired on fixtured models. Each hood is factoryprepared for up to four electrical duplexes and an airflow monitor. Interior working dimensions are offered in standard and larger depths. Working depths include 30", 36" and 48". Performance tested to ASHRAE By-pass airflow design ensures relatively stable face velocities. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed on fixtured models. Each hood is factory prepared for up to eight service fixtures (four on each side). Service access panels allow easy accessibility to plumbing from the front and inside of the hood. Chemical-resistant, fiberglassreinforced composite panel liner surpasses all national codes for flame spread and has a bright white surface for excellent light reflectivity. 33

37 Protector XL Floor-Mounted Laboratory Hoods Protector XL Floor-Mounted Laboratory Hood Blower and ductwork must be ordered separately. Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side. Protector XL Floor-Mounted Laboratory Hood Blower and ductwork must be ordered separately. All models feature: By-pass airflow design. Glacier white, dry powder epoxy-coated steel exterior. Chemical-resistant, fiberglass-reinforced composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84. Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light and blower switches for 115 volt, 60 Hz operation. Shipped in multiple sections, top and bottom. Epoxy-coated stainless steel, 12.81" ID exhaust connection(s). 4', 5', 6' and 8' models feature: Two 3/16" thick tempered safety glass vertical-rising sashes framed with PVC (4', 5' and 6' models) or epoxy-coated aluminum (8' models). 8', 10', 12' and 16' models feature: Four 3/16" thick tempered safety glass horizontal-sliding sashes with epoxycoated aluminum frames and sash tracks. All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Snuffer Fire Extinguishers. See page 110. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 34

38 Ordering Information 4', 5', 6' and 8' Protector XL Floor-Mounted Laboratory Hoods with vertical-rising sashes Nominal Catalog Exterior Interior 12.81" ID Fluorescent Service Electrical Shipping Width Number Depth (A) Depth (B) Exhaust Collar(s) Lamps Fixtures Duplex Weight lbs./kg 4 Feet " 30" 1 2 ea. 25 watt / " 36" 1 2 ea. 25 watt / " 48" 1 2 ea. 25 watt /331 5 Feet " 30" 1 2 ea. 32 watt / " 36" 1 2 ea. 32 watt / " 48" 1 2 ea. 32 watt /381 6 Feet " 30" 1 2 ea. 32 watt / " 36" 1 2 ea. 32 watt / " 48" 1 2 ea. 32 watt /449 8 Feet " 30" 2 4 ea. 25 watt / " 36" 2 4 ea. 25 watt / " 48" 2 4 ea. 25 watt /653 Nominal Total Exhaust CFM and Static Pressure with sashes 50% open Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " 4 Feet Series 48" 5 Feet Series 60" Side View All models A 7" 58.81" Sash Opening 68.15" Viewing Height to Floor 38.25" 50.25" 68.15" Viewing Height to Floor 58.81" Sash Opening B Upper Cabinet Lower Cabinet 77" 95" 84" 36" 6 Feet Series 72" 8 Feet Series 96" 62.25" 68.15" 58.81" Viewing Sash Height to Opening Floor 86.25" 68.15" Viewing Height to Floor 59.00" Sash Opening See additional dimensional data on page

39 Ordering Information 8', 10', 12' and 16' Protector XL Floor-Mounted Laboratory Hoods with horizontal-sliding sashes Nominal Catalog Exterior Interior 12.81" ID Fluorescent Service Electrical Shipping Width Number Depth (A) Depth (B) Exhaust Collars Lamps Fixtures Duplex Weight lbs./kg 8 Feet " 30" 2 4 ea. 25 watt / " 36" 2 4 ea. 25 watt / " 48" 2 4 ea. 25 watt / Feet " 30" 2 4 ea. 32 watt / " 36" 2 4 ea. 32 watt / " 48" 2 4 ea. 32 watt / Feet " 30" 2 4 ea. 32 watt / " 36" 2 4 ea. 32 watt / " 48" 2 4 ea. 32 watt / Feet " 30" 4 8 ea. 25 watt / " 36" 4 8 ea. 25 watt / " 48" 4 8 ea. 25 watt /1579 Nominal Sashes Total Exhaust CFM and Static Pressure Width Open 100 fpm S.P. 80 fpm S.P. 8 Feet " " 10 Feet " " 12 Feet " " 16 Feet " 8 Feet Series 10 Feet Series Side View All models 96" 120" A 7" 86.25" 68.15" Viewing Height to Floor " 68.15" Viewing Height to Floor B Upper Cabinet Lower Cabinet 77" 95" 84" 36" 12 Feet Series 144" 16 Feet Series 192" " 68.15" Viewing Height to Floor " 68.15" Viewing Height to Floor See additional dimensional data on page

40 Dimensional Data 4', 5' and 6' Protector XL Benchtop Laboratory Hoods 4.91" 2.27" C B 12.81" ID Exhaust Collar TOP 2.5" dia. Service Fixture Supply Holes 10.53" Single Point Internal Junction Box A B C D E 4' Hood " 38.25" 24" 39.20" 30" " 38.25" 24" 45.20" 36" " 38.25" 24" 33.20" 24" ' Hood " 50.25" 30" 39.20" 30" " 50.25" 30" 45.20" 36" " 50.25" 30" 33.20" 24" ' Hood " 62.25" 36" 39.20" 30" " 62.25" 36" 45.20" 36" " 62.25" 36" 33.20" 24" D Fluorescent Lights 4.19" Front Access Panel (one on each side) 28" Sash Opening 32.15" A B FRONT Viewing Height to Work Surface Service Fixture (one on each side on fixtured models) 115 Volt, 20 Amp Duplex Electrical Receptacle (one on fixtured models) 16.44" 2.00" E Sash Frame to Baffle SIDE Interior Access Panel 41" 48" 59" Contact Labconco at or for detailed AutoCAD drawings. 37

41 Dimensional Data 8', 10', 12' and 16' Protector XL Benchtop Laboratory Hoods A B C D E F G 4.91" 2.27" E 2.5" dia. Service Fixture Supply Holes B D 10.53" 8' Hood , " 86.25" 42.84" 48" 24" 39.20" 30" , " 86.25" 42.84" 48" 24" 45.20" 36" , " 86.25" 42.84" 48" 24" 33.20" 24" 10' Hood , " " 54.84" 50" 35" 39.20" 30" , " " 54.84" 50" 35" 45.20" 36" , " " 54.84" 50" 35" 33.20" 24" 12.81" ID Exhaust Collars TOP (8', 10', 12') F Single Point Internal Junction Box 12' Hood , " " 66.84" 62" 41" 39.20" 30" , " " 66.84" 62" 41" 45.20" 36" , " " 66.84" 62" 41" 33.20" 24" 16' Hood , " " 44.84" End 48" 24" 39.20" 30" 46" Center Four (Four Sashes) Collars , " " 44.84" End 48" 24" 45.20" 36" 46" Center Four (Four Sashes) Collars , " " 44.84" End 48" 24" 33.20" 24" 46" Center Four (Four Sashes) Collars 2.5" dia. Service Fixture Supply Holes 4.91" E D B D 10.53" 2.27" 12.81" ID Exhaust Collars 12.81" ID Exhaust Collars F Single Point Internal Junction Box TOP (16') F 28" Sash Opening B 32.15" Viewing Height to Work Surface A FRONT C Front Fixture Panel (one on each side) Service Fixture (one on each side on fixtured models) 115 Volt, 20 Amp Duplex Electrical Receptacle (one on fixtured models) 1 Fluorescent Lights 16.44" 2.00" G Sash Frame to Baffle Interior Access Panel SIDE 41" 4.19" 48" 59" Contact Labconco at or for detailed AutoCad drawings. 38

42 Dimensional Data Protector XL HOPEC IV Laboratory Hoods 4', 5', and 6' Hoods 4.91" 2.27" A B C " 38.25" 24" " 50.25" 30" " 62.25" 36" 4.87" 4.87" B C 8.69" ID Exhaust Collar 2.5" dia. Service Fixture Supply Holes 10.53" Single Point Internal Junction Box 15" Sash Stop Opening 30" Sash Opening A 6" Viewing Panel 37" Viewing Height to Work Surface B Front Access Panel (one on each side) 1.37" 60.25" 39.20" 29.50" Sash Frame to Baffle Sash Enclosure 6.81" 41" 48" 59" TOP 4' Single Sash Not Shown FRONT 1.25" 6.28" 1.50" Trough SIDE Interior Access Panel 8' Hoods 4.87" 4.87" 86.25" 24" 48" 4.91" 2.5" dia. Service Fixture Supply Holes 10.53" 7.23" 2.98" 1.78" 2.27" 1.42".39" 1.3" 8.69" ID Exhaust Collar Single Point Internal Junction Box.75" 6.28" Trough and Air Foil Enlarged Detail 1.23" SIDE VIEW TOP 96" 1.37" 39.20" Sash Enclosure Fluorescent Lights 6.81" 30" Sash Opening 37" Viewing Height to Work Surface 6" Viewing Panel Front Access Panel (one on each side) on ide) 60.25" 29.50" Sash Frame to Baffle 41" 48" 59" 15" Sash Stop Opening 86.25" FRONT 1.25" 6.28" 1.50" Trough Interior Access Panel SIDE Contact Labconco at or for detailed AutoCAD drawings. 39

43 Dimensional Data 4', 5', 6' and 8' Protector XL Floor-Mounted Laboratory Hoods with vertical-rising sashes 4.91" 2.27" 4.91" 2.27" TOP (8') C D 12.81" ID Exhaust Collar TOP 4', 5', 6' C 10.53" 2.5" dia. Service Fixture Supply Holes E Single Point Internal Junction Box 2.5" dia. Service Fixture Supply Holes D B 12.81" ID Exhaust Collars E 10.53" Single Point Internal Junction Box A B C D E F G 4' Hood " 24" 38.25" 39.20" 30" 58.81" " 24" 38.25" 45.20" 36" 58.81" " 24" 38.25" 57.20" 48" 58.81" 5' Hood " 30" 50.25" 39.20" 30" 58.81" " 30" 50.25" 45.20" 36" 58.81" " 30" 50.25" 57.20" 48" 58.81" 6' Hood " 36" 62.25" 39.20" 30" 58.81" " 36" 62.25" 45.20" 36" 58.81" " 36" 62.25" 57.20" 48" 58.81" 8' Hood " 48" 24" 86.25" 39.20" 30" 59.00" " 48" 24" 86.25" 45.20" 36" 59.00" " 48" 24" 86.25" 57.20" 48" 59.00" A E Fluorescent Lights Front Access Panel (one on each side) 7" 68.15" Viewing Height to Floor G Sash Opening Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 2.00" Interior Access Panels Upper Cabinet Lower Base F 77" 95" 84" 36" D Sash Frame to Baffle FRONT SIDE Contact Labconco at or for detailed AutoCAD drawings. 40

44 Dimensional Data 8', 10', 12' and 16' Protector XL Floor-Mounted Laboratory Hoods with horizontal-sliding sashes A B C D E F G H 4.91" 2.27" E 2.5" dia. Service Fixture Supply Holes F D 12.81" ID Exhaust Collars G 10.53" Single Point Internal Junction Box 8' Hood " 43.25" 22.5" 48" 24" 86.25" 39.20" 30" " 43.25" 22.5" 48" 24" 86.25" 45.20" 36" " 43.25" 22.5" 48" 24" 86.25" 57.20" 48" 10' Hood " 55.25" 28.5" 50" 35" " 39.20" 30" " 55.25" 28.5" 50" 35" " 45.20" 36" " 55.25" 28.5" 50" 35" " 57.20" 48" 12' Hood " 67.25" 34.5" 62" 41" " 39.20" 30" " 67.25" 34.5" 62" 41" " 45.20" 36" " 67.25" 34.5" 62" 41" " 57.20" 48" 16' Hood " 91.25" 46.5" 48" 24" " 39.20" 30" (Four Collars) TOP 8', 10', 12' " 91.25" 46.5" 48" 24" " 45.20" 36" (Four Collars) " 91.25" 46.5" 48" 24" " 57.20" 48" (Four Collars) 2.5" dia. Service Fixture Supply Holes 4.91" E D F D 10.53" 2.27" 12.81" ID Exhaust Collars 12.81" ID Exhaust Collars G Single Point Internal Junction Box TOP (16') A Fluorescent Lights G Front Access Panel (one on each side) 7" F 68.15" Viewing Height to Floor B Max Opening C Door Width Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 2.00" Interior Access Panels Upper Cabinet Lower Base H 77" 95" 84" 36" Sash Frame to Baffle FRONT SIDE Contact Labconco at or for detailed AutoCAD drawings. 41

45 Protector ClassMate Laboratory Hood is shown with SpillStopper Work Surface and Protector Acid Storage Cabinet

46 Protector ClassMate Laboratory Hoods Features & Benefits The patented* Protector ClassMate Laboratory Hoods are designed to meet the needs of instructional laboratories. Clear back and sides and taller front viewing window provide enhanced visibility for conducting chemistry demonstrations or observing students using the hood. The clear back does not obstruct visibility when hoods are placed back-to-back in an island configuration. Protector ClassMate Hoods are offered in 4', 5' and 6' widths. HOPEC IV models with combination sashes are also available. Durable and attractive frame is glacier white, dry powder epoxy-coated steel and aluminum. Energy-efficient, rapid-start fluorescent lighting is located behind a laminated safety glass shield and outside the hood interior for corrosionresistance and easy replacement. Contact Labconco for ordering information on explosion-proof lighting. Ergonomic 5 angled sash and panel allow closer, more comfortable viewing, without glare. Clear, tempered safety glass sash, viewing panel, sides, back and baffle provide maximum visibility. All glass components except verticalrising sashes are removable for cleaning. Laminated safety glass and solid composite sides and back are also available. Contact Labconco for ordering information. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of sash position. Four service fixtures are pre-plumbed on fixtured models. Each hood is factory prepared for up to 8 service fixtures (four controlled from the front of the hood and four from the base cabinet). By-pass airflow design ensures relatively stable face velocities. Performance tested to ASHRAE Front panel may be easily removed for lamp replacement and access to electrical supply connections. Streamlined corner posts provide maximum visibility and working area. Static viewing panel above the sash frame creates a 39 viewing height, permitting the hood to be mounted in a low or high position to accommodate persons of different heights and still maintain the same visual accessibility. Anti-racking vertical-rising sash for smooth operation may be raised from closed to 29" fully open height from the work surface for loading and cleaning. A sash stop limits the working height to 18" to help conserve energy. Exhaust volume and blower sizing are based on the 18" height. When raised, the sash does not extend above the fume hood. Combination horizontalsliding/vertical-rising sashes are provided on 5' and 6' HOPEC IV models. Two sets of integral sash stops prevent raising the vertical sash above the halfopen (15") and fully-closed positions unless manually defeated by the operator. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s junction boxes. Two electrical duplex receptacles are factory-wired on fixtured models. Baffle directs airflow to the rear of the interior to provide efficient airflow. For cleaning, the entire baffle may be removed or upper baffle tilted up and the lower baffle tilted down. Low profile trough below air foil contains spills. The trough is the same depth as the work surface (1.25") and requires no cabinet overhang. The air foil pivots up for cleaning. Interior cover plates allow easy accessibility to plumbing from the front and inside of the hood. ETL-listed. Hoods carry the ETL mark signifying that they are certified to / , UL 1805 and CAN/CSA C22.2 No Ergonomic air foil allows air to sweep the work surface for maximum containment. Clean-Sweep** airflow openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. Exclusive Feature Tissue screen located directly below the exhaust outlet prevents debris from potentially damaging the remote blower. Large interior working depth of 26" and height of 48" provide ample space to conduct experiments. *U.S. Design Patent No. 472,645 **U.S. Patent No. 6,461,233 43

47 Protector ClassMate Laboratory Hoods Tissue screen located directly below exhaust outlet. Removable front panel and interior cover plates for access to plumbing and electrical wiring. Epoxy-coated steel 8.63" ID exhaust connection. All models conform to the following regulations and standards: SEFA ASHRAE ANSI Z UL / CAN/CSA C22.2 No Fixtured models feature: Four pre-plumbed service fixtures with forged brass valves; three with 0.25" copper tubing for use with cold water, air and vacuum, and one with 0.25" brass tubing for use with gas. Inlet tubing is not provided. Two pre-wired 115 volt, 20 amp electrical duplex receptacles. All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Work Surface. See pages Base Cabinet. See pages Protector ClassMate Laboratory Hood is shown with SpillStopper Work Surface and Protector Acid Storage Cabinet Blower, ductwork, work surface and base cabinet must be ordered separately. All models feature: Patented* design. By-pass airflow design. Glacier white, dry powder epoxy-coated steel and aluminum frame. Ergonomic air foil with aerodynamic Clean-Sweep** airflow openings. Low profile, ADA-compliant spill trough that requires no cabinet overhang. Removable, clear, 1/4" thick, tempered safety glass sides, back and baffle. 5 angled, tempered safety glass, 1/4" thick viewing window and 3/16" thick sash with anti-racking shaft and epoxycoated aluminum frames that provides 39" high visibility. Sash stop at 18" height from work surface (60% open). Fully open sash is 29" from work surface. Pre-wired fluorescent lighting, light switch and blower switch for 115 volt, 60 Hz, 15 amp operation. Optional accessories for on-site installation include: Distillation Grid Kits. See page 110. Guardian Jr. and Digital Airflow Monitors. See page 108. Rear Finish Panel Kits. See page 109. Service Fixtures. Contact Labconco. Exclusive Feature * U.S. Design Patent No. 472,645 ** U.S. Patent No. 6,461,233 Heights of switches, electrical receptacles and service fixtures meet requirements of ADA. 44

48 Ordering Information & Dimensional Data Protector ClassMate Laboratory Hoods Nominal Total Exhaust CFM and Static Pressure at 18" sash opening height (60% open)* Width 100 fpm S.P. 80 fpm S.P. 60 fpm S.P. 4 Feet " " " 5 Feet " " " 6 Feet " " " *Contact Labconco for other sash opening height data. Nominal Catalog Fluorescent Service Electrical Shipping Width Number Lamps Fixtures Duplexes Weight lbs./kg 4 Feet ea. 30 watt None None 400/181 4 Feet ea. 30 watt /181 5 Feet ea. 40 watt None None 460/209 5 Feet ea. 40 watt /209 6 Feet ea. 40 watt None None 550/249 6 Feet ea. 40 watt /249 B 8.63" ID Exhaust Collar with Tissue Screen 1.25".50" Electrical Junction Boxes Under Cover Plumbing Inlet Lines 7.54" 23.75" REF 2.00" REF Plumbing Inlet Lines A B C 4' Hood 48" 24" 45" 5' Hood 60" 30" 57" 6' Hood 72" 36" 69" TOP FRONT A 27.65" Fluorescent Lights 7.00" 115 Volt, 20 Amp Duplex Electrical Receptacle (one on each side on fixtured models) Service fixture (two on each side on fixtured models) 10.00" Viewing Panel 39.00" Viewing Height 29.00" Sash Opening to Work Surface 18.00" Sash Stop Height C FRONT 60.25" 48.00" Interior Height Sash to Baffle 25.75" 1.25" Trough 2.00" 23.75" 32.25" 59.00" 2.00" Plumbing Inlet Lines SIDE SIDE Contact Labconco at or for detailed AutoCAD drawings. 45

49 Protector ClassMate HOPEC IV Laboratory Hoods Epoxy-coated steel sash pocket behind the front panel. Epoxy-coated steel 8.63" ID exhaust connection. All models conform to the following regulations and standards: SEFA ASHRAE ANSI Z ADA UL / CAN/CSA C22.2 No Fixtured models feature: Pre-wired digital airflow monitor. Four pre-plumbed, WaterSaver service fixtures with forged brass valves; three with 0.25" copper tubing for use with cold water, air and vacuum, and one with 0.25" brass tubing for use with gas. Cold water fixture is left-side mounted rigid gooseneck faucet. Inlet tubing is not provided. Two pre-wired 115 volt, 15 amp electrical duplex receptacles. Protector ClassMate HOPEC IV Laboratory Hood is shown with SpillStopper Work Surface , Protector Solvent Storage Cabinet and Protector Acid Storage Cabinet Blower, ductwork, work surface and base cabinets must be ordered separately. All models feature: Patented* design. Hand operated, positive energy control (HOPEC) modified by-pass airflow design. Glacier white, dry powder epoxy-coated steel and aluminum frame. Combination horizontal-sliding/verticalrising sashes** that allow the operator to use the hood with sashes half open either horizontally or vertically. Sash stops at fully closed and 15" height from work surface (50% open). Sash stops at the 50% open (15") and fully-closed positions along with a sash pocket that blocks the upper by-pass and reduces amount of air exhausted. Highly visible yellow, ergonomic air foil with aerodynamic Clean-Sweep airflow openings and recessed sash track. Low profile, ADA-compliant spill trough that requires no cabinet overhang. Clear, 1/4" thick, tempered safety glass sides, back and baffle, all removable for cleaning. 5 angled, tempered safety glass, 1/4" thick sash and stationary viewing panel** to provide viewing height of 39" for visual accessibility regardless of mounting height. Pre-wired fluorescent lighting, light switch and blower switch for 115 volt, 60 Hz, 15 amp operation. Tissue screen located directly below exhaust outlet. Removable front panel and interior. cover plates for access to plumbing and electrical wiring. All models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. Work Surface. See pages Base Cabinet. See pages Optional accessories for on-site installation include: Distillation Grid Kits. See page 110. Rear Finish Panels. See page 109. Guardian Jr. and Digital Airflow Monitors. See page 108. Service Fixtures. Contact Labconco. Exclusive Feature *U.S. Design Patent No. 472,645 U.S. Patent No. 6,461,233 **4' models have single vertical-rising sash with opening height of 29" and stationary panel WaterSaver Faucet Company Heights of switches, electrical receptacles and service fixtures meet requirements of ADA. 46

50 Ordering Information & Dimensional Data Protector ClassMate HOPEC IV Laboratory Hoods Nominal Total Exhaust CFM and Static Pressure at 50% open horizontally or vertically Width 100 fpm S.P. 80 fpm S.P. 60 fpm S.P. 4 Feet " " " 5 Feet " " " 6 Feet " " " Nominal Catalog Fluorescent Service Electrical Digital Shipping Width Number Lamps Fixtures Duplexes Monitor Weight lbs./kg 4 Feet ea. 30 watt None None No 485/220 4 Feet ea. 30 watt 4 2 Yes 485/220 5 Feet ea. 40 watt None None No 570/259 5 Feet ea. 40 watt 4 2 Yes 570/259 6 Feet ea. 40 watt None None No 680/308 6 Feet ea. 40 watt 4 2 Yes 680/308 B 8.63" ID Exhaust Collar with Tissue Screen 1.25".50" Electrical Junction Boxes Under Cover 7.54" 2.00" REF A B C D Plumbing Inlet Lines 23.75" REF Plumbing Inlet Lines 4' Hood 48" 24" 45" N/A 5' Hood 60" 30" 57" 26" 6' Hood 72" 36" 69" 32" TOP FRONT A 27.65" Fluorescent Lights Gooseneck Faucet (on fixtured models) 115 Volt, 20 Amp Duplex Electrical Receptacle (one on each side on fixtured models) Service Fixture (two on each side on fixtured models) 10.00" Viewing Panel D 15" Sash Stop Height (4' Single Sash Not Shown) FRONT C 39.00" Viewing Height Digital Airflow Monitor (on fixtured models) 60.25" 48.00" Interior Height Sash to Baffle 26.25" 1.25" Trough 2.25" 23.75" 32.25" 7.00" 59.00" 2.00" Plumbing Inlet Lines SIDE Contact Labconco at or for detailed AutoCAD drawings. 47

51 Protector Stainless Steel Radioisotope Laboratory Hood is shown with Protector Acid Storage Cabinet

52 Protector Stainless Steel Radioisotope Laboratory Hoods Features & Benefits Protector Stainless Steel Radioisotope Laboratory Hoods provide protection from applications requiring the use of radiochemicals. Available in 4', 5', 6' and 8' widths, these benchtop hoods feature a corrosion-resistant Type 304 stainless steel interior. The onepiece liner is free of joints, cracks or crevices to prevent build-up of residue and simplify decontamination procedures. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. By-pass airflow design ensures stable face velocities that meet or exceed established standards. Durable and attractive exterior is glacier white, dry powder epoxycoated steel. Pre-set baffle has been designed to provide a uniform face velocity pattern across the sash opening of the hood. Large 28" sash opening offers superior viewing. When fully open, the sash does not extend above the hood. Vertical-rising tempered safety glass sash is anti-racking for smooth operation. Service access panels allow accessibility to plumbing from the front of the hood. Corrosion-resistant, Type 304 stainless steel liner with integral work surface provides a seamless work area. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factory-wired on fixtured models. Each hood is factoryprepared for up to four electrical duplexes and an airflow monitor. Hardboard surface to support integral work surface is included. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed. Each corner post is factory-prepared for up to 4 service fixtures (8 fixtures total per hood). Additional service fixtures require holes drilled in the liner at the factory or on site. Ergonomic air foil allows air to sweep the work surface for maximum containment. Clean-Sweep* airflow openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and CAN/CSA C22.2 No Performance tested to ASHRAE Fluorescent lighting illuminates the interior. The high-efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. Exclusive Feature * U.S. Patent No. 6,461,233 49

53 Protector Stainless Steel Radioisotope Laboratory Hoods ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 All models require (not included): Dedicated Remote Blower. See back pocket. Ductwork. Type 304 stainless steel duct is recommended. Contact Labconco for source recommendations. Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Sash Stop Kits. See page 108. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. With Sash Full Open 100 fpm Protector Stainless Steel Radioisotope Laboratory Hood is shown with Protector Acid Storage Cabinet Blower, ductwork and base cabinet must be ordered separately. All models feature: By-pass airflow design. Glacier white, dry powder epoxy-coated steel exterior. Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings. Seamless Type 304 stainless steel liner with integral work surface and pre-set baffle(s). Black enamel-coated hardboard surface to support the integral work surface. 3/16" thick tempered safety glass vertical-rising sash with frame of epoxycoated aluminum and PVC. Removable front and side panels and front access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light switch and blower switch for 115 volt, 60 Hz operation to single point internal junction box. Two pre-plumbed service fixtures with forged brass valves and chrome-plated brass serrated hose connectors, lower right side with brass tubing for gas and lower left side with copper tubing for air. Components for converting either or both fixtures to cold water and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side " OD Type 304 stainless steel exhaust connection(s). All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 Nominal Total Exhaust CFM and Static Pressure Width CFM S.P. 4 Feet " 5 Feet " 6 Feet " 8 Feet " With Sash 60% Open 100 fpm** Nominal Total Exhaust CFM and Static Pressure Width CFM S.P. 4 Feet " 5 Feet " 6 Feet " 8 Feet " Exclusive Feature * U.S. Patent No. 6,461,233 ** Sash stop required Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 50

54 Ordering Information & Dimensional Data Protector Stainless Steel Radioisotope Laboratory Hoods Nominal Catalog Electrical 11.00" OD Fluorescent Service Electrical Shipping Width Number Requirements Exhaust Collar(s) Sash Lamps Fixtures Duplex Weight lbs./kg 4 Feet volts, 60 Hz ea. 25 watt /231 5 Feet volts, 60 Hz ea. 32 watt /291 6 Feet volts, 60 Hz ea. 32 watt /318 8 Feet volts, 60 Hz ea. 25 watt / " 2.27" C B 10.53" 2.5" dia. Service Fixture Supply Holes A B C 4' Hood 48" 38.25" 24" 5' Hood 60" 50.25" 30" 11.00" OD Type 304 Stainless Steel Exhaust Collar* Single Point Internal Junction Box 6' Hood 72" 62.25" 36" 8' Hood 96" 86.25" 24"* * 8' model has two exhaust collars, 24.00" on each side of centerline TOP A 33.20".81" Fluorescent Lights Front Access Panel (one on each side) 28.00" Sash Opening 32.15" Viewing Height to Work Surface B FRONT Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 16.44" 2.00" 3.20" 23.50" Sash Frame to Baffle Hardboard Surface SIDE 48" 59" 1.25" Contact Labconco at or for detailed AutoCAD drawings. 51

55 Protector Stainless Steel Perchloric Acid Laboratory Hood is shown with Protector Acid Storage Cabinet

56 Protector Stainless Steel Perchloric Acid Laboratory Hoods Features & Benefits Protector Stainless Steel Perchloric Acid Laboratory Hoods are designed specifically for procedures involving the use of perchloric acid. They feature washdown systems, integral work surfaces and drainage troughs so that they may be thoroughly rinsed after each use to prevent the accumulation of potentially reactive perchloric salts. Available in 4', 5', 6' and 8' widths, these benchtop hoods feature a corrosion-resistant Type 316 stainless steel interior to withstand reaction from perchloric acid. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. By-pass airflow design ensures stable face velocities that meet or exceed established standards. Durable and attractive exterior is glacier white, dry powder epoxy-coated steel. Performance tested to ASHRAE Pre-set baffle has been designed to provide a uniform face velocity pattern across the sash opening of the hood. Large 28" sash opening offers superior viewing. When fully open, the sash does not extend above the hood. Vertical-rising tempered safety glass sash is antiracking for smooth operation. Service access panels allow accessibility to plumbing from the front of the hood. Corrosion-resistant, Type 316 stainless steel liner with integral work surface and drainage trough provides a seamless work area. Pre-wired electrical components. Fluorescent lights, switches and one 115 volt, 60 Hz electrical duplex receptacle are factory-wired to the hood s single point junction box. Each hood is factory-prepared for up to four electrical duplexes and an airflow monitor. Hardboard surface to support integral work surface is included. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed. Corner posts are factory-prepared for up to four remote control knobs (eight fixtures total per hood). Additional service fixtures require holes drilled in the liner at the factory or on site. Built-in washdown system facilitates the removal of hazardous perchlorates from hood interior. The system consists of pre-plumbed internal piping, spray nozzles and upper left sidemounted remote control knob. * U.S. Patent No. 6,461,233 Ergonomic air foil allows air to sweep the work surface for maximum containment. Clean-Sweep* airflow openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. Exclusive Feature Fluorescent lighting illuminates the interior. The high efficiency, instant start T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and CAN/CSA C22.2 No

57 Protector Stainless Steel Perchloric Acid Laboratory Hoods All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 All models require (not included): Dedicated remote PVC Blower. See back pocket. Wash Rings and other ductwork. See back pocket. Base Cabinet or Stand. See pages Protector Stainless Steel Perchloric Acid Laboratory Hood is shown with Protector Acid Storage Cabinet Blower, ductwork and base cabinet must be ordered separately. All models feature: By-pass airflow design. Glacier white, dry powder epoxy-coated steel exterior. Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings. Seamless Type 316 stainless steel liner (23.5" interior depth) with integral work surface, drainage trough and pre-set baffle(s). Black enamel-coated hardboard surface to support the integral work surface. 3/16" thick tempered safety glass vertical-rising sash with frame of epoxy-coated aluminum and PVC. Removable front and side panels and front access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light switch and blower switch for 115 volt, 60 Hz operation to single point internal junction box. Built-in washdown system with internal piping and spray nozzles behind the baffle and remote control fixture on upper left side. Washdown fitting located on top of hood to facilitate connection to external wash rings (wash rings not included). Two pre-plumbed service fixtures with forged brass valves and chrome-plated brass serrated hose connectors, lower right side with brass tubing for gas and lower left side with copper tubing for air. Components for converting either or both fixtures to cold water and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side. 11" OD Type 316 stainless steel exhaust connection(s). Contact Labconco at or for ordering information on additional service fixtures and blower sizing assistance. Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Sash Stop Kits. See page 108. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. With Sash Full Open 100 fpm Nominal Total Exhaust CFM and Static Pressure Width CFM S.P. 4 Feet " 5 Feet " 6 Feet " 8 Feet " With Sash 60% Open 100 fpm** Nominal Total Exhaust CFM and Static Pressure Width CFM S.P. 4 Feet " 5 Feet " 6 Feet " 8 Feet " Exclusive Feature * U.S. Patent No. 6,461,233 ** Sash stop required 54

58 Ordering Information & Dimensional Data Protector Stainless Steel Perchloric Acid Laboratory Hoods Nominal Catalog Electrical 11.00" OD Fluorescent Service Electrical Spray Shipping Width Number Requirements Exhaust Collar(s) Sash Lamps Fixtures Duplex Nozzles Weight lbs./kg 4 Feet volts, 60 Hz ea. 25 watt /238 5 Feet volts, 60 Hz ea. 32 watt /276 6 Feet volts, 60 Hz ea. 32 watt /306 8 Feet volts, 60 Hz ea. 25 watt / " 2.27" C B 10.53" 2.5" dia. Service Fixture Supply Holes A B C D E 4' Hood 48" 38.25" 24" 34" 14.88" 5' Hood 60" 50.25" 30" 46" 20.88" 11.00" OD Type 316 Stainless Steel Exhaust Collar* Single Point Internal Junction Box 6' Hood 72" 62.25" 36" 58" 26.88" 8' Hood 96" 86.25" 24"* 82" 38.88" * 8' model has two exhaust collars, 24.00" on each side of centerline TOP A 33.20".81" Fluorescent Lights Washdown Control Knob Front Access Panel (one on each side) 28.00" Sash Opening 32.15" Viewing Height to Work Surface B Drainage Trough E C L 2.12" D FRONT Service Fixture (one on each side) Volt, 20 0 Amp Duplex Electrical Receptacle 16.44" 3.20" Hardboard H Surface Washdown Nozzle 23.50" Sash Frame to Baffle 30.00" Washdown Drain 2.38" OD SIDE 59" 48" 2.85" 4.66" 6.41" 2.32" 1.25" 5.89" Contact Labconco at or for detailed AutoCAD drawings. 55

59 Protector PVC Perchloric Acid Laboratory Hood is shown with Protector Acid Storage Cabinet

60 Protector PVC Perchloric Acid & Acid Digestion Laboratory Hoods Features & Benefits Protector PVC Perchloric Acid Laboratory Hoods feature washdown systems, integral work surfaces and drainage troughs so that they may be thoroughly rinsed after each use to prevent the accumulation of potentially reactive perchloric salts. Their liners of Type 1 unplasticized polyvinyl chloride are designed to withstand reaction from perchloric acid and other highly corrosive inorganic chemicals. Protector PVC Acid Digestion Laboratory Hoods feature Lexan* sashes, which are recommended for applications involving the use of acids including hydrofluoric acid but not perchloric acid. Durable and attractive exterior is glacier white, dry powder epoxy-coated steel. By-pass airflow design ensures stable face velocities that meet or exceed established standards. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. Performance tested to ASHRAE Pre-set baffle has been designed to provide a uniform face velocity pattern across the sash opening of the hood. Large 28" sash opening offers superior viewing. When fully open, the sash does not extend above the hood. Vertical-rising tempered safety glass sash is antiracking for smooth operation. Protector PVC Acid Digestion Hoods feature a Lexan* polycarbonate sash that resists fogging or etching when exposed to hydrofluoric acid fumes. Service access panels allow accessibility to plumbing from the front of the hood. Corrosion-resistant liner of Type 1 unplasticized PVC with integral work surface provides a seamless work area. Pre-wired electrical components. Fluorescent lights, switches and one 115 volt, 60 Hz electrical duplex receptacle are factory-wired to the hood s single point junction box. Each hood is factory-prepared for up to four electrical duplexes and an airflow monitor. Hardboard surface to support integral work surface is included. Color-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed. Corner posts are factory-prepared for up to 4 remote control knobs (8 fixtures total per hood). Additional service fixtures require holes drilled in the liner at the factory or on site. Built-in washdown system facilitates the removal of hazardous perchlorates from hood interior. The system consists of pre-plumbed internal piping, spray nozzles and upper left sidemounted remote control knob. ** U.S. Patent No. 6,461,233 Ergonomic air foil allows air to sweep the work surface for maximum containment. Clean-Sweep** airflow openings pull inflow air from under the air foil so that clean air continually flows over the air foil creating a constant barrier of protection from contaminants. Exclusive Feature Fluorescent lighting illuminates the interior. The high efficiency, instant start T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and CAN/CSA C22.2 No * Lexan is a registered trademark of General Electric Company 57

61 Protector PVC Perchloric Acid & Acid Digestion Laboratory Hoods Protector PVC Acid Digestion Laboratory Hoods feature: 1/4" thick Lexan polycarbonate verticalrising sash with frame of epoxy-coated aluminum and PVC. Lexan resists etching by hydrofluoric acid fumes. All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 Protector PVC Perchloric Acid Laboratory Hood is shown with Protector Acid Storage Cabinet Blower, ductwork and base cabinet must be ordered separately. All models feature: By-pass airflow design. Glacier white, dry powder epoxy-coated steel exterior. Ergonomic air foil with aerodynamic Clean-Sweep* airflow openings. Heat-welded unplasticized PVC liner (30.0" interior depth) with integral work surface, drainage trough and pre-set baffle(s). Black enamel-coated hardboard surface to support the integral work surface. Removable front and side panels and front access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light switch and blower switch for 115 volt, 60 Hz operation to single point internal junction box. Built-in washdown system with internal piping and spray nozzles behind the baffle and remote control fixture on upper left side. Washdown fitting located on top of hood facilitates connection to external wash rings (wash rings not included). Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing and plastic serrated hose connector for gas and lower left side with copper tubing and gray PVC rigid gooseneck faucet for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side " OD PVC exhaust connection(s). Protector PVC Perchloric Acid Laboratory Hoods feature: 3/16" thick tempered safety glass vertical-rising sash with frame of epoxy-coated aluminum and PVC. Glass is suitable for perchloric acid use. All models require (not included): Dedicated remote PVC Blower. See back pocket. Wash Rings and other ductwork. See back pocket. Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 107. Electrical Duplex Kits. See page 108. Guardian Jr. and Digital Airflow Monitor Kits. See page 108. Ceiling Enclosure and Rear Finish Panel Kits. See page 109. With Sash Full Open 100 fpm Nominal Total Exhaust CFM and Static Pressure Width CFM S.P. 4 Feet " 6 Feet " 8 Feet " * U.S. Patent No. 6,461,233 Exclusive Feature 58

62 Ordering Information & Dimensional Data Protector PVC Perchloric Acid & Acid Digestion Laboratory Hoods Nominal Catalog Electrical 12.75" OD Fluorescent Service Electrical Spray Shipping Width Number Requirements Exhaust Collar(s) Sash Lamps Fixtures Duplex Nozzles Weight lbs./kg Protector PVC Perchloric Acid Laboratory Hoods 4 Feet volts, 60 Hz ea. 25 watt /170 6 Feet volts, 60 Hz ea. 32 watt /227 8 Feet volts, 60 Hz ea. 25 watt /283 Protector PVC Acid Digestion Laboratory Hoods 4 Feet volts, 60 Hz ea. 25 watt /170 6 Feet volts, 60 Hz ea. 32 watt /227 8 Feet volts, 60 Hz ea. 25 watt / " dia. Service Fixture Supply Holes 4.91" 2.27" C B 10.53" A B C D E 4' Hood 48" 38.25" 24" 34" 14.50" 12.75" OD PVC Exhaust Collar* Single Point Internal Junction Box 6' Hood 72" 62.25" 36" 58" 26.50" 8' Hood 96" 86.25" 24"* 82" 38.50" * 8' model has two exhaust collars, 24.00" on each side of centerline TOP A 39.20".25" Fluorescent Lights Washdown Control Knob Front Access Panel (one on each side) 28.00" Sash Opening 32.15" Viewing Height to Work Surface Drainage E Trough C L 2.50" D B FRONT Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 16.44" 2.00" 3.20" Hardboard Surface SIDE 30.00" Sash Frame to Baffle 36.00" Washdown Drain 2.38" OD 59" 48" 2.91" 4.66" 6.66" 2.49" 1.25" 4.03" Contact Labconco at or for detailed AutoCAD drawings. 59

63 Basic 47 Laboratory Hood is shown with Flat Solid Epoxy Work Surface and Protector Acid Storage Cabinet Inset: Basic 70 Laboratory Hood is shown with Flat Solid Epoxy Work Surface and two Protector Standard Storage Cabinets

64 Basic Laboratory Hoods Features & Benefits Basic 47 and 70 Laboratory Hoods are designed specifically for laboratories, classrooms and light duty applications where safe ventilation is required on a regular basis. Constructed of epoxy-coated steel, Basic Hoods are economical and have a smaller overall height and depth than traditional hoods so they fit in areas with low ceilings or narrow aisles. Choose from 4' and 6' widths. Front panel may be easily removed for lamp replacement and access to blower and electrical connections. Durable and attractive exterior is glacier white, dry powder epoxy-coated steel. Versatile blower mounts on top of the hood liner or in a remote location. Hoods are also available without blower. CE mark*. All 230 volt, 50 Hz models conform to CE (European Community) requirements for electrical safety and electromagnetic compatibility. Two-piece baffle is adjustable. The right side fixture panel is factory-prepared for up to three color-coded service fixtures, one duplex electrical receptacle and an airflow monitor. Vapor-proof incandescent lighting illuminates the interior. Explosion-proof models include an explosion-proof incandescent light fixture (bulb not included). Top of the hood liner is factory-prepared to accommodate two customersupplied apparatus rods. Vertical-rising tempered safety glass sash protects the operator while providing excellent visibility. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / and CAN/CSA C22.2 No The curved air foil directs airflow into the hood to minimize turbulence and ensure fume containment. The foil lifts off for cleaning. Unassembled models available. Components fit into a carton less than one half its assembled size. The compact container is more economical to ship and store than assembled hood cartons and transports readily to remote locations. Assembly is simple and fast. Unassembled models are not pre-wired. Performance tested to ASHRAE The right interior wall is factory-prepared to accommodate an accessory cupsink and turret (sold separately). Compact dimensions accommodate tight installations. The 48" height, 53" with built-in blower, makes it ideal for laboratories with lower ceiling heights. Overall depth of 25" makes it adaptable to shallow cabinetry. Durable epoxy-coated 16 gauge steel liner resists chemical degradation. Pre-wired electrical components. Incandescent lighting and switches are factory-wired to the hood s junction box. Explosion-proof models are furnished without switches and wiring as these must conform to varying local codes. * pending Exclusive Feature 61

65 Basic Laboratory Hoods Vapor-proof models feature: Pre-wired 100-watt vapor-proof incandescent light, light and blower switches. Explosion-proof models feature: Explosion-proof incandescent light fixture. (Requires installation. Bulb not included.) Furnished without switches and wiring as these must conform to varying local codes. Models with blower module feature: Belt-driven blower with adjustable sheave. Epoxy-coated steel base and housing. Corrosion-resistant coated aluminum impeller. Unassembled models feature: Basic 47 Hood carton dimensions: 51" w x 39" d x 14.5" h. Basic 70 Hood carton dimensions: 74" w x 39" d x 14.5" h. Blower carton dimensions (if applicable): 20" w x 28" d x 16" h. Basic 47 Laboratory Hood is shown with Flat Solid Epoxy Work Surface and Protector Acid Storage Cabinet Blower module is included. Ductwork, work surface and base cabinet must be ordered separately. All models feature: By-pass airflow design. Curved air foil that lifts off for cleaning. Glacier white, dry powder epoxy-coated, 16 gauge steel exterior and interior. Two-piece adjustable baffle. 3/16" thick tempered safety glass. vertical-rising sash with epoxy-coated aluminum sash handle Removable front panel for access to lighting and electrical wiring. Factory-prepared right side fixture panel for up to three service fixtures, one duplex electrical receptacle and one airflow monitor (fixtures, receptacle and monitor not included). Factory-prepared right interior wall for one cupsink and turret (cupsink and turret not included). Factory-prepared top of hood liner for two apparatus rods (rods not included). Epoxy-coated steel 10.31" ID exhaust connection. All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No CE Conformity Marking (230 volt models)* All models require (not included): Remote blower. See page 65 and back pocket.** Ductwork. See back pocket. Work Surface. See page 95. Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 65. Electrical Duplex Kits. See page 65. Guardian Jr. and Digital Airflow Monitor Kits. See page 65. Cupsink and Turret Kit. See page 65. Sash Stop Kit. See page 65. Right Side Finish Panel Kit. See page 65. Snuffer Fire Extinguishers. See page 110. * pending ** Many models include a blower module. Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 62

66 Ordering Information & Dimensional Data Basic 47 Laboratory Hoods Basic 47 Hoods with Blower Module Capable of overcoming a maximum external static pressure of.25" H 2 O at 720 CFM (100 fpm). Overall dimensions: 47.00" wide x 25.00" deep x 53.00" high (with blower module mounted on top of hood). Nominal Catalog Electrical Incandescent Blower Equivalent Assembly Shipping Width Number Requirements Lamp Motor Resistance* Configuration Weight lbs./kg 10" dia. 12" dia. 4 Feet volts, 60 Hz Vapor-Proof 1/3 hp 100' 250' Fully Assembled 370/ ** 220 volts, 50 Hz Vapor-Proof 1/2 hp 100' 250' Fully Assembled 370/ /230 volts, 60 Hz EP 1/3 hp, EP 100' 250' Fully Assembled 375/ ** 220 volts, 50 Hz EP 1/3 hp, EP 100' 250' Fully Assembled 375/ volts, 60 Hz Vapor-Proof 1/3 hp 100' 250' Unassembled 272/123 29/ ** 220 volts, 50 Hz Vapor-Proof 1/2 hp 100' 250' Unassembled 272/123 29/ /230 volts, 60 Hz EP 1/3 hp, EP 100' 250' Unassembled 272/123 41/ ** 220 volts, 50 Hz EP 1/3 hp, EP 100' 250' Unassembled 272/123 41/19 Basic 47 Hoods for use with remote blower Static pressure loss does not exceed.35" H 2 O at 100 fpm (720 CFM). Overall dimensions: 47.00" wide x 25.00" deep x 48.00" high. Nominal Catalog Electrical Incandescent Assembly Shipping Width Number Requirements Lamp Configuration Weight lbs./kg 4 Feet volts, 60 Hz Vapor-Proof Fully Assembled 275/ ** 220 volts, 50 Hz Vapor-Proof Fully Assembled 275/ volts, 60 Hz Vapor-Proof Unassembled 272/ ** 110/220 volts, 50 Hz Vapor-Proof Unassembled 272/ /230 volts, 50/60 Hz EP Unassembled 272/123 EP = explosion-proof * Maximum length of straight duct to achieve 100 fpm face velocity ** International electrical configuration Bulb not included Shipping weight of separate blower carton Exhaust Duct 10.31" OD (Hoods without Blower Module) 3.25" Exhaust Duct 10.31" OD (Hoods with Blower Module) 10.38" 3.25" Blower Module 10.13" 25.00" 22.13" TOP 24.88" TOP (Hoods (Hoods without blower module) module) Junction Box 25.00" 10.13" 22.13" TOP 24.88" TOP (Hoods with blower module) 5.88" Junction Box 48.00" 26.00" Sash Opening/ 27.13" Viewing Height to Work Surface 41.25" 53.00" 17.63" Sash Frame To Baffle Incandescent Light Blower Module Detail 43.19" Inside 47.00" FRONT SIDE 8.50" 14.50" 9.88" 4.25" 20.50" Blower Outlet 10.31" OD 16.00" 7.00" 1.00" 23.00" 26.00" 28.25" TOP Blower Inlet 10.88" ID FRONT 3.00" 14.50" SIDE 63

67 Ordering Information & Dimensional Data Basic 70 Laboratory Hoods Basic 70 Hoods with Blower Module Capable of overcoming a maximum external static pressure of.23" H 2 O at 1120 CFM (100 fpm). Overall dimensions: 70.00" wide x 25.00" deep x 53.00" high (with blower module mounted on top of hood). Nominal Catalog Electrical Incandescent Blower Equivalent Assembly Shipping Width Number Requirements Lamp Motor Resistance* Configuration Weight lbs./kg 10" dia. 12" dia. 6 Feet volts, 60 Hz Vapor-Proof 3/4 hp 45' 100' Fully Assembled 450/ ** 220 volts, 50 Hz Vapor-Proof 3/4 hp 45' 100' Fully Assembled 450/ /230 volts, 60 Hz EP 3/4 hp, EP 45' 100' Fully Assembled 455/ ** 220 volts, 50 Hz EP 3/4 hp, EP 45' 100' Fully Assembled 455/ volts, 60 Hz Vapor-Proof 3/4 hp 45' 100' Unassembled 426/193 29/ ** 220 volts, 50 Hz Vapor-Proof 3/4 hp 45' 100' Unassembled 426/193 41/ /230 volts, 60 Hz EP 3/4 hp, EP 45' 100' Unassembled 426/193 41/ ** 220 volts, 50 Hz EP 3/4 hp, EP 45' 100' Unassembled 426/193 41/19 Basic 70 Hoods for use with remote blower Static pressure loss does not exceed.57" H 2 O at 100 fpm (1120 CFM). Overall dimensions: 70.00" wide x 25.00" deep x 48.00" high. Nominal Catalog Electrical Incandescent Assembly Shipping Width Number Requirements Lamp Configuration Weight lbs./kg 6 Feet volts, 60 Hz Vapor-Proof Fully Assembled 430/ ** 220 volts, 50 Hz Vapor-Proof Fully Assembled 430/ volts, 60 Hz Vapor-Proof Unassembled 426/ ** 110/220 volts, 50 Hz Vapor-Proof Unassembled 426/ /230 volts, 50/60 Hz EP Unassembled 426/193 EP = explosion-proof * Maximum length of straight duct to achieve 100 fpm face velocity ** International electrical configuration Bulb not included Shipping weight of separate blower carton Exhaust Duct 10.31" OD (Hoods without Blower Module) 3.25" Blower Module 25.00" 10.13" 33.63" 36.38" TOP (Hoods without blower module) (Hoods without blower module) Junction Box 48.00" 26.00" Sash Opening/ 27.13" Viewing Height to Work Surface 64.25" 53.00" 17.63" Sash Frame To Baffle Incandescent Light Exhaust Duct 10.31" OD (Hoods with Blower Module) 21.88" 3.25" 66.19" Inside 70.00" FRONT SIDE 10.13" 5.88" 25.00" Junction Box 33.63" 36.38" TOP (Hoods with TOP blower module) (Hoods with blower module) 64

68 Accessories Basic Laboratory Hoods Duplex Electrical Receptacle Kits Each kit includes duplex electrical receptacle, junction box and receptacle cover plate. For mounting on the lower right side fixture panel. Electrical wiring is not included. Catalog # Kit Shipping Wt volts, 20 amps AC 4 lbs. (1.8 kg) volts, 20 amps AC, GFCI 4 lbs. (1.8 kg) Guardian Digital Airflow Monitor Kits An LCD displays actual face velocity. Audible/visual alarm alerts user to low face velocity. For installation in a factory-prepared cutout on upper portion of right side fixture panel. Shipping weight 6 lbs. (2.7 kg) Catalog # Description Guardian Digital Airflow Monitor for 115 volt, 60 Hz operation ** Guardian Digital Airflow Monitor for 230 volt, 50 Hz operation Cupsink and Turret Kit Polypropylene cupsink, 3" x 6", and chrome turret mount on right side wall. Plumbing pipe is not included. Shipping weight 0.5 lb. (0.2 kg) GUARDIAN AIRFLOW MONITOR SYSTEM ALERT NORM TEST RESET Guardian Jr. Airflow Monitor Kits Audible/visual alarm alerts user to low face velocity. For installation in a factory-prepared cutout on upper portion of right side fixture panel. Shipping weight 6 lbs. (2.7 kg) Standard Service Fixture Kits Each kit includes one remotely-controlled service fixture with 0.25" diameter valve and tubing, color-coded fixture knob and color-coded hose connector. For mounting on the right side fixture panel. Shipping weight 4 lbs. (1.8 kg.) Knob/ Catalog # Kit Tubing Valve Connector Color Cold Water (CW) Copper Brass Green Hot Water (HW) Copper Brass Red Deionized/ Stainless Nickel-Plated/ White Distilled Water (DI) Steel Stainless Steel Vacuum (VAC) Copper Brass Yellow Air (AIR) Copper Brass Orange Gas (GAS) Brass Brass Blue Nitrogen (NIT) Copper Brass Brown Argon (ARG) Copper Brass Gray Steam (STM) Copper Brass Black Catalog # Description Guardian Jr. Airflow Monitor for 115 volt, 60 Hz operation ** Guardian Jr. Airflow Monitor for 230 volt, 50 Hz operation Glass Sash Sash Stop Sash Handle ** International electrical configuration Sash Stop Kit The Sash Stop restricts how far the sash may be opened. This small plastic device may be easily installed on the left side of Basic Hoods to restrict sash opening height. Shipping weight 0.5 lb. (0.2 kg) Right Side Finish Panel Kit Includes a glacier white epoxy-coated steel panel to provide a finished appearance to the right side of the hood. The panel hides the exposed plumbing when service fixtures are installed. Not for use with Cupsink and Turret. Shipping weight 20 lbs. (9 kg) Blower Modules The Blower Module may be mounted behind the front panel of the Basic Hood, in-line in the ductwork, or remotely on the roof. Beltdriven with an adjustable sheave. Weather-resistant epoxy-coated steel base and housing. Coated aluminum impeller resists corrosion from mild to moderate chemical fumes. Explosion-proof models include an explosion-proof motor. See page 63 for dimensional data. NOTE: A Blower Module is included with all Basic Hoods except Models , , , , , , , , and Purchase a separate Blower Module only when selecting a blower for an existing hood. Catalog Numbers Motor Data CFM & RPM Ranges at Static Pressure inches H 2 O* Description HP Electrical F.L Shipping Std. E.P. Requirements Amps RPM RPM RPM Wt.(lbs./kg) Blower /3 115V/60 Hz/1ø /45 Modules /3 115/230V/60 Hz/1ø 5.8/ /45 for Basic /2 110/220V/50 Hz/1ø 9.2/ /45 Hoods /3 110/220V/50 Hz/1ø 6.2/ /45 Blower /4 115V/60 Hz/1ø /50 Modules /4 115/230V/60 Hz/1ø 11.4/ /50 for Basic /4 110/220V/50 Hz/1ø 12.0/ /50 Hoods /4 110/220V/50 Hz/1ø 11.4/ /50 E.P. = explosion-proof *External static pressure loss in addition to the hood s static pressure loss 65

69 Fiberglass 30 Laboratory Hoods Fiberglass 30 Laboratory Hood is shown with Flat Solid Epoxy Work Surface and Protector Standard Storage Cabinet Remote blower, ductwork, work surface and base cabinet must be ordered separately. Compact Fiberglass 30 Laboratory Hoods are designed for research, educational and clinical applications requiring small working space and efficient fume removal. Like the Protector Premier line, these hoods feature a corrosion-resistant, one-piece molded fiberglass liner. Ordering Information All models feature: By-pass airflow design. Durable glacier white, dry powder epoxy-coated steel exterior. One-piece molded fiberglass interior and pre-set baffle with flame spread index less than 25 per ASTM E-84. 3/16" thick tempered safety glass vertical-rising sash with epoxy-coated aluminum handle. Pivoting air foil. Right side fixture panel factory-prepared to accept up to three service fixtures, one electrical duplex and one airflow monitor (kits are sold separately). 6.69" ID fiberglass exhaust connection. All models conform to the following regulations and standards: SEFA NFPA ASTM E84-01 ASHRAE ANSI Z UL / CAN/CSA C22.2 No UL 1805 CE Conformity Marking (230 volt models)* Models and feature: Built-in corrosion-resistant, direct drive exhaust blower capable of overcoming a maximum external static pressure of.12" H 2 O at 310 CFM (100 fpm). Pre-wired 100 watt, vapor-proof incandescent light, light and blower switches. Models and : Designed for use with remote blower (not included). Static pressure loss does not exceed.14" H 2 O at 100 fpm (310 CFM). Pre-wired 100 watt, vapor-proof incandescent lamp, light and blower switches. Models and feature: Built-in corrosion-resistant, explosionproof, direct drive exhaust blower capable of overcoming a maximum external static pressure of.12" H 2 O at 310 CFM (100 fpm). Furnished without light, switches or wiring. Wiring must conform to local codes. (Explosion-proof Light Fixture Kit is available. See page 67.) All models require (not included): Ductwork. See back pocket. Work Surface. See page 95. Base Cabinet or Stand. See pages Optional accessories for on-site installation include: Service Fixture Kits. See page 67. Electrical Duplex Kits. See page 67. Guardian Jr. and Digital Airflow Monitor Kits. See page 67. Explosion-Proof Light Fixture Kit. See page 67. * pending Catalog Built-in Equivalent Electrical Vapor-Proof Dimensions Shipping Number Blower Resistance** Requirements Lamp (w x d x h) Weight lbs./kg 6" dia. 8" dia /10 HP, Std. 20' 80' 115 volts, 60 Hz 100 watt 30.00" x 30.16" x 48.00" 122/ /3 HP, Std. 20' 80' 230 volts, 50 Hz 100 watt 30.00" x 30.16" x 52.00" 122/ None 115 volts, 60 Hz 100 watt 30.00" x 30.16" x 48.00" 96/ None 230 volts, 50 Hz 100 watt 30.00" x 30.16" x 48.00" 96/ /4 HP, EP 20' 80' 115 volts, 60 Hz None 30.00" x 30.16" x 54.00" 129/ /3 HP, EP 20' 80' 230 volts, 50 Hz None 30.00" x 30.16" x 54.00" 129/59 EP = Explosion-proof ** Maximum length of straight duct to achieve 100 fpm face velocity International electrical configuration 66

70 Accessories & Dimensional Data Fiberglass 30 Laboratory Hoods Duplex Electrical Receptacle Kits Each kit includes duplex electrical receptacle, wiring, junction box and receptacle cover plate. For mounting on the lower right side fixture panel. Catalog # Kit Shipping Wt volts, 20 amps AC 4 lbs. (1.8 kg) volts, 20 amps AC, GFCI 4 lbs. (1.8 kg) 8.24" 6.69" ID Exhaust Collar 8.92" 13.05" TOP 11.65" Motor (with Built-in Blower) Standard Service Fixture Kits Each kit includes one remotely-controlled service fixture with 0.25" diameter valve and tubing, color-coded fixture knob and color-coded hose connector. For mounting on the right side fixture panel. Shipping weight 4 lbs. (1.8 kg.) 28.00" Viewing Height 20.00" Sash Opening 25.00" Inside 30.00" FRONT 48.00" 36.00" Interior Height 29.00" 22.67" Sash Frame to Baffle 30.16" SIDE Catalog # Kit Tubing Valve Knob/Connector Color Cold Water (CW) Copper Brass Green Hot Water (HW) Copper Brass Red Deionized/ Stainless Nickel-Plated/ White Distilled Water (DI) Steel Stainless Steel Vacuum (VAC) Copper Brass Yellow Air (AIR) Copper Brass Orange Gas (GAS) Brass Brass Blue Nitrogen (NIT) Copper Brass Brown Argon (ARG) Copper Brass Gray Steam (STM) Copper Brass Black Guardian Digital Airflow Monitor Kits An LCD displays actual face velocity. Audible/visual alarm alerts user to low face velocity. For installation in a factory-prepared cutout on upper portion of right side fixture panel. Shipping weight 6 lbs. (2.7 kg) Catalog # Description Guardian Digital Airflow Monitor for 115 volt, 60 Hz operation ** Guardian Digital Airflow Monitor for 230 volt, 50 Hz operation 8.92" 13.17" 8.24" 6.69" ID Exhaust Collar 28.00" Viewing Height Motor 8.92" 8.24" 6.69" ID Exhaust Collar TOP 20.00" Sash Opening 25.00" Inside 30.00" FRONT TOP 11.22" Motor 52.00" 36.00" 48.00" Interior Height 29.00" (with Built-in Blower) 22.67" Sash Frame to Baffle 30.16" SIDE and (for use with Remote Blower) GUARDIAN AIRFLOW MONITOR SYSTEM ALERT NORM TEST RESET Guardian Jr. Airflow Monitor Field Installation Kits Audible/visual alarm alerts user to low face velocity. For installation in a factory-prepared cutout on upper portion of right side fixture panel. Shipping weight 6 lbs. (2.7 kg) 28.00" Viewing Height 20.00" Sash Opening 25.00" Inside 30.00" FRONT 48.00" 36.00" Interior Height 29.00" 22.67" Sash Frame to Baffle 30.16" SIDE Catalog # Description Guardian Jr. Airflow Monitor for 115 volt, 60 Hz operation ** Guardian Jr. Airflow Monitor for 230 volt, 50 Hz operation 8.24" 6.69" ID Exhaust Collar 8.92" 13.17" 11.22" and (with Built-in Explosion-Proof Blower) Explosion-Proof Motor Explosion-Proof Light Fixture Kit For mounting on Fiberglass 30 Hood or Includes explosion-proof incandescent light fixture, mounting hardware and instructions. 13" h x 7" diameter. Bulb and electrical wiring are not included. Shipping weight 11 lbs. (5 kg) TOP Explosion-Proof Motor 54.00" ** International electrical configuration 28.00" Viewing Height 20.00" Sash Opening 25.00" Inside 30.00" FRONT 48.00" 36.00" Interior Height 22.67" Sash Frame to Baffle 30.16" SIDE 67

71 Paramount 72 Filtered Enclosure is shown with Flat Work Surface and two Base Cabinets Inset: Paramount 360 Filtered Enclosure is shown with Paramount Electric Hydraulic Lift Base Stand The Paramount Hydraulic Lift Base Stand can be lowered so that the Paramount Filtered Enclosure and Stand can pass through an 80" high doorway, ensuring portability for sharing among classrooms and laboratories or for storage.

72 Paramount Filtered Enclosures Features & Benefits Paramount Filtered Enclosures are self-contained work stations that use carbon filters to rid the laboratory of annoying or unsafe concentrations of organic solvents, formaldehyde, acid gases or ammonia. Unlike traditional fume hoods, they require no ducting and can be moved from lab to lab. Paramount Duet Filtered Enclosures use both carbon-based and 99.99% efficient HEPA filters for removing gaseous and particulate contaminants. These enclosures are suited to clean room and other applications that use chemicals that generate fumes, vapors and/or particulates yet require ISO Class 5 (formerly Class 100) conditions. Color-Smart Filter Cells used in the Paramount are sold separately and come in five types: Ammonia, Acid Gas, Organic, Formaldehyde and HEPA. See page 81 for application discussion and ordering information. LCD message center provides continuous filter status reports and displays alarm messages. Built-in blower is quiet, nonsparking and corrosion-resistant. Durable construction. Sides and sash are tempered safety glass that won t easily discolor or craze like plastic. The frame is glacier white, dry powder epoxy-coated aluminum. Programming touchpad and two built-in timers allow the user to program the filter check and change times through the LCD. Alert messages appear after the user-specified number of hours has elapsed. Filter clamping mechanism with gas-assisted lift opens effortlessly and applies uniform pressure across the entire top surface of the filter cells for leak-proof, one-step filter replacement from the front of the enclosure. Color-Smart Filter Cells are sold separately. Single-piece, two-position tempered safety glass sash is angled to allow closer, more comfortable viewing without glare. Set at 13" sash opening to work surface, face velocity is 100 fpm; at 15", velocity is 80 fpm. The sash pivots up for loading and cleaning. Convenient utility ports allow passage of tubing and electrical cords from equipment inside the enclosure through the back for connection to services. Roughing prefilters remove dust and other particulates, extending the life of the Color- Smart Filter Cells. Audible/visual alarm reminds the user to check the filters using sampling tubes or to replace the filters. The alarm can be programmed to alert after the blower has run for a preset period of time. On models with organic vapor sensors, the same alarm activates when high concentrations of organic vapors are detected by the sensors. Fluorescent lights illuminate the interior and are replaceable from the front. Air-mixing rear baffle extends filter life, ensures safe and rapid fume removal and distributes an even concentration of contaminants to the filters for uniform loading. Paramount 360 Filtered Enclosures have a clear, tempered safety glass baffle for 360 of visibility, ideal for training or classroom demonstrations. The glass baffle pivots down for cleaning. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / and CAN/CSA C22.2 No Air foil directs airflow into the hood to ensure fume containment. Performance tested to ASHRAE Fully assembled and prewired. Mount the Paramount on existing cabinetry or accessory work surface and base, install filters, plug into an electrical outlet and it s ready to use. CE mark. All 230 volt, 50 Hz models conform to the CE (European Community) requirements for electrical safety and electromagnetic compatibility. Exclusive Feature 69

73 Paramount Filtered Enclosures All models conform to the following regulations and standards: SEFA ASHRAE ANSI Z UL / CAN/CSA C22.2 No CE Conformity Marking (230 volt models) Paramount 360 Filtered Enclosure models feature: Clear, 3/16" thick tempered safety glass baffle and back panel. The baffle pivots down for cleaning. Models with vapor sensors feature: Two vapor sensors for detection of organic vapors with concentrations of 50 ppm or greater. One sensor is located in the filter bed and one in the exhaust air stream. Upon detection, the sensors activate the audible/visual alarm. Paramount 360 Filtered Enclosure is shown with Mobile Base Stand Color-Smart Filter Cells and supporting base must be ordered separately. All models feature: Glacier white, dry powder epoxy-coated aluminum construction. 3/16" thick tempered safety glass sides. Air-mixing, epoxy-coated steel rear baffle.* Two roughing pre-filters. Two 1.5" diameter utility ports with plastic plugs. Gas-assisted filter clamping mechanism. Control panel with LCD for display of filter time elapsed; programmable timer for audio/visual alarm; ALARM/MUTE switch with LED indicator; SET FILTER TIME, UP/DOWN, and ENTER programming switches; and event timer. Built-in, non-sparking motor/blower. Pre-wired with two 20-watt fluorescent lights and switches for blower and light. Angled 1/4" thick tempered safety glass sash, adjustable to two operating height positions (13" and 15" to work surface), pivots to full open position (24.25") for cleaning and transfer of material. Face velocity of 100 fpm (236 CFM) when sash opening to work surface is 13" and 80 fpm (236 CFM) when sash opening is 15". Air sampling syringe for test port. Shipped fully assembled. Exclusive Feature All models require (not included): Work Surface and Base. See pages Color-Smart Filter Cells. See pages HEPA Color-Smart Filter Cells (for Duet models only). See pages Optional accessories (see page 75): Replacement Roughing Prefilters Electrostatic Prefilters Exhaust Collar Kit (for outside ducting) * Baffle on Paramount 360 models is tempered safety glass. 70

74 Paramount Easy Order Ordering Information & Dimensional Data Paramount Filtered Enclosures Paramount Easy Order includes all the components needed for a complete Paramount Enclosure System from ceiling to floor. Order just one catalog number, , and receive the following items: Paramount Filtered Enclosure for 115 volts, 60 Hz operation as described below Mobile Base Stand as described on page Organic Color-Smart Filter Cells as described on pages Organic 360 Model Duet Model Nominal Catalog Electrical 8-Foot Power Vapor Clear Requires Shipping Width Number Requirements Cord & Plug Sensors Back & Baffle HEPA Filters Weight lbs./kg Models without Organic Sensors 3 Feet volts, 60 Hz, 3 amps 290/ * 230 volts, 50 Hz, 1.5 amps no plug 290/ volts, 60 Hz, 3 amps 290/ * 230 volts, 50 Hz, 1.5 amps no plug 290/ volts, 60 Hz, 3 amps 290/ * 230 volts, 50 Hz, 1.5 amps no plug 290/ volts, 60 Hz, 3 amps 290/ * 230 volts, 50 Hz, 1.5 amps no plug 290/132 Models with Organic Sensors volts, 50 Hz, 3 amps 290/ volts, 50 Hz, 1.5 amps no plug 290/ volts, 60 Hz, 3 amps 290/ volts, 50 Hz, 1.5 amps no plug 290/ volts, 60 Hz, 3 amps 290/ * 230 volts, 50 Hz, 1.5 amps no plug 290/ volts, 60 Hz, 3 amps 290/ * 230 volts, 50 Hz, 1.5 amps no plug 290/132 * International electrical configuration Series Models are for use when organic vapors are expected to exceed 50 ppm. For applications involving organic vapors with concentrations below 50 ppm, Series Models are recommended. For help in determining concentration levels for your applications, contact Labconco at or See pages 80 and 81 for ordering information on Color-Smart Filter Cells " 11.75" PARAMOUNT FILTERED ENCLOSURE LABCONCO Non-Duet Models 53.38" TOP 30" Viewing Height to Work Surface 13" and 15" Sash Opening Duet Models 56.88" 33.75" 24.25" 34" Interior 36" FRONT 29" SIDE 71

75 Paramount 72 Filtered Enclosures All models conform to the following regulations and standards: SEFA ASHRAE ANSI Z UL / CAN/CSA C22.2 No CE Conformity Marking (230 volt models) Paramount 360 Filtered Enclosure models feature: Clear, 3/16" thick tempered safety glass baffles and back panel. When set screws are loosened, the baffles pivot down for cleaning. Models with vapor sensors feature: Two vapor sensors for detection of organic vapors with concentration of 50 ppm or greater. One sensor is located in the filter bed. Upon detection, the vapor sensor activates the audible/visual alarm. A second sensor is located in the exhaust air stream and, upon detection, activates the audible/visual alarm. Paramount 72 Filtered Enclosure is shown with Dished Work Surface and two Base Cabinets Color-Smart Filtered Cells must be ordered separately. All models feature: Glacier white, dry powder epoxy-coated aluminum construction. 3/16" thick tempered safety glass sides. Air-mixing, epoxy-coated steel rear baffle.* Four roughing pre-filters. Four 1.5" diameter utility ports with plastic plugs. Two gas-assisted filter clamping mechanisms. Control panel with LCD for display of filter time elapsed; programmable timer for audio/visual alarm; ALARM/MUTE switch with LED indicator; SET FILTER TIME, UP/DOWN, and ENTER programming switches; and event timer. Two built-in, non-sparking motor/blowers. Pre-wired with four 20-watt fluorescent lights and switches for blower and light. Angled, 1/4" thick tempered safety glass sash, adjustable to two operating height positions (13" and 15" to work surface), pivots to full open position (24.25") for cleaning and transfer of material. Face velocity of 100 fpm (472 CFM) when sash opening to work surface is 13" and 80 fpm (472 CFM) when sash opening is 15". Air sampling syringe for test port. Shipped fully assembled. All models require (not included): Work Surface and Base. See pages Two sets of Color-Smart Filter Cells. See pages Two sets of HEPA Color-Smart Filter Cells (for Duet models only). See pages Optional accessories (see page 75): Replacement Roughing Prefilters Electrostatic Prefilters Exhaust Collar Kits (for outside ducting) Exclusive Feature * Baffle on Paramount 360 models is tempered safety glass. 72

76 Ordering Information & Dimensional Data Paramount 72 Filtered Enclosures Organic 360 Model Duet Model Nominal Catalog Electrical 8-Foot Power Vapor Clear Requires Shipping Width Number Requirements Cord & Plug Sensors Back & Baffle HEPA Filters Weight lbs./kg Models without Organic Sensors 6 Feet volts, 60 Hz, 6 amps 580/ * 230 volts, 50 Hz, 3 amps no plug 580/ volts, 60 Hz, 6 amps 580/ * 230 volts, 50 Hz, 3 amps no plug 580/ volts, 60 Hz, 6 amps 580/ * 230 volts, 50 Hz, 3 amps no plug 580/ volts, 60 Hz, 6 amps 580/ * 230 volts, 50 Hz, 3 amps no plug 580/264 Models with Organic Sensors volts, 50 Hz, 6 amps 580/ volts, 50 Hz, 3 amps no plug 580/ volts, 60 Hz, 6 amps 580/ volts, 50 Hz, 3 amps no plug 580/ volts, 60 Hz, 6 amps 580/ * 230 volts, 50 Hz, 3 amps no plug 580/ volts, 60 Hz, 6 amps 580/ * 230 volts, 50 Hz, 3 amps no plug 580/264 * International electrical configuration Series Models are for use when organic vapors are expected to exceed 50 ppm. For applications involving organic vapors with concentrations below 50 ppm, Series Models are recommended. For help in determining concentration levels for your applications, contact Labconco at or See pages 80 and 81 for ordering information on Color-Smart Filter Cells " 23.50" 11.75" TOP PARAMOUNT FILTERED ENCLOSURE LABCONCO PARAMOUNT FILTERED ENCLOSURE LABCONCO Non-Duet Models 53.38" 13" and 15" Sash Opening 30" Viewing Height to Work Surface Duet Models 56.88" 33.75" 24.25" 70" Interior 29" 72" FRONT SIDE 73

77 Paramount Electric & Manual Hydraulic Lift Base Stands Paramount Electric Hydraulic Lift Base Stand may be lowered to 21.5" high to allow for easy access to filters. Paramount Base Stands offer both height flexibility and portability for Paramount Filtered Enclosures. The hydraulic lift adjustment accommodates persons of different heights and allows for easier access to the Paramount Enclosure s upper chamber for filter testing and replacement. Manual and electric hydraulic lift models are offered. The Stands have a unique low profile, caster-mounting design so that the Paramount Filtered Enclosure may be lowered to pass through an 80" high doorway, ensuring portability for sharing among classrooms and laboratories or for storage. Paramount Electric Hydraulic Lift Base Stand Features (All Models): Support Paramount Filtered Enclosures. Support loads up to 1000 pounds. ADA-compliant. Durable 1.75" tubular, epoxy-coated steel frame with rear crossbar supports. Support frame is 2.0" x 3.0" tubular steel. Attractive glacier white finish complements laboratory casework and Paramount Filtered Enclosures. Hydraulic lift legs have infinite adjustment from 21.5" to 33.5" high. Include four 3" diameter, non-marking polyurethane casters with bearings for quiet operation. Include 1" thick gray solid epoxy work surface. Surface is dished on 3-foot models; flat on 6-foot models. Dimensions Electric ELECTRIC Lift LIFT A B FRONT MANUAL Manual LIFT Lift A FRONT 4.4" 10.3" 21.5" MIN 33.5" MAX 1.5" 5.0" 5.4" 12.8" 29.3" 23.8" SIDE 29.3" 23.8" SIDE 10.4" Features (Electric Hydraulic Lift Models): Include front-accessible, right-side mounted up/down switch. Available in two electrical configurations. Models for 115 volts, 60 Hz operation include a 12-foot, 3-wire cord and plug. Models for 230 volt, 50 Hz operation include a 12-foot, 3-wire cord and a NEMA 6-15P plug.* Electrical components are UL listed. Features (Manual Hydraulic Lift Models): Include front-accessible, right-side mounted hand crank. Turning the crank clockwise raises the stand; counterclockwise lowers it. The handle may be folded under, out of the way, when not in use. 21.5" MIN 33.5" MAX 1.5" 6.5" 5.0" 10.4" 3-Foot Models A B , , " 37.2" B FRONT Ordering Information SIDE 6-Foot Models , , " 73.2" Nominal Hydraulic Overall Electrical Shipping Width Catalog # Lift Width x Depth Requirements Weight lbs./kg For Use With: 3 feet Electric 36.0" w x 29.0" d 115 volts, 60 Hz, 2.4 amps 200/91 3' Paramount Filtered Enclosure 3 feet * Electric 36.0" w x 29.0" d 230 volts, 50 Hz, 0.8 amps 200/91 3' Paramount Filtered Enclosure 3 feet Manual 36.0" w x 29.0" d not applicable 180/82 3' Paramount Filtered Enclosure 6 feet Electric 72.0" w x 29.0" d 115 volts, 60 Hz, 2.4 amps 350/159 6' Paramount Filtered Enclosure 6 feet * Electric 72.0" w x 29.0" d 230 volts, 50 Hz, 0.8 amps 350/159 6' Paramount Filtered Enclosure 6 feet Manual 72.0" w x 29.0" d not applicable 330/150 6' Paramount Filtered Enclosure * International electrical configuration. The NEMA 6-15P plug may require replacement with a different plug to match the user s intended receptacle. 74

78 Accessories Paramount Filtered Enclosures Replacement Roughing Prefilters Remove dust and other particulates, extending the life of Color-Smart Filter Cells. Labconco recommends replacing prefilters whenever changing Color-Smart Filter Cells. 1 pair. Shipping weight 3 lbs. (1.4 kg) Electrostatic Prefilters Remove aerosols, mist and fine particles, extending the life of Color-Smart Filter Cells. These optional prefilters are used in place of Roughing Prefilters for removal of aerosols. 1 pair. Shipping weight 3 lbs. (1.4 kg) Exhaust Collar Kit Permits connection of the Paramount to 6" diameter PVC duct for optional exhausting to the outside. Includes 8" x 6" thermoplastic duct reducer and 7" diameter flexible duct connection with 2 clamps. Paramount 72 Enclosures require two collars. Remote blower is required. Contact Labconco at or for blower selection assistance. Mobile Base Stands Glacier white epoxy-coated tubular steel frame with 5" diameter, toe-locking casters. Include solid epoxy work surface. Stand is 37.2" high. Catalog # Description Dimensions Shipping Weight ' Stand with Dished Surface 36" w x 29.25" d x 1" thick 155 lbs. (70 kg) ' Stand with Flat Surface 72" w x 29.25" d x 1" thick 265 lbs. (116 kg) Dished Work Surface for 3' Paramount Filtered Enclosures For use on existing cabinetry. Included with Mobile Base Stand and Base Cabinet Gray solid epoxy " w x 29.25" d x 1.00" thick. Shipping weight 70 lbs. (32 kg) Flat Work Surface for 6' Paramount Filtered Enclosures For use on existing cabinetry or with 2 each Base Cabinets. Included with Mobile Base Stand Gray solid epoxy " w x 29.25" d x 1.00" thick. Shipping weight 160 lbs. (59 kg) Base Cabinet with 3' Dished Work Surface Epoxy-coated steel cabinet with work surface supports 3' Paramount Filtered Enclosure. Interior shelf stores one set of Filter Cells (not included). Includes four leveling feet and one 8" filler panel to increase cabinet depth from 22.00" to 30.00". Cabinet dimensions: 36.00" w x 22.00" d x " high. Work surface dimensions: 36.00" w x 29.25" d x 1.00" thick. Shipping weight 260 lbs. (118 kg) Base Cabinet without work surface Epoxy-coated steel base cabinet. Interior shelf stores one set of Filter Cells (not included). Includes four leveling feet and one 8" filler panel to increase cabinet depth from 22.00" to 30.00". Dimensions: 36.00" w x 22.00" d x " high. Shipping weight 190 lbs. (86 kg). Order two each Base Cabinets and one each Flat Work Surface to support Paramount 72 Filtered Enclosure. 75

79 Protector VS Ventilation Station is shown with Solid Epoxy Work Surface and Protector Solvent Storage Cabinet Inset: Protector VS Ventilation Station is shown with Solid Epoxy Work Surface , Telescoping Base Stand and Protector FilterMate Mobile Station

80 Protector VS Ventilation Stations Features & Benefits Protector VS Ventilation Stations are enclosures that provide an economical alternative to heavy duty fume hoods. With their low profile and clear sides, top and sash, VS Stations are well suited for classroom and educational laboratory environments where supervision or demonstrations are required. They can also be used as weighing stations, light duty fume hoods, solvent cleaning work bays, and veterinary pathology and cytology enclosures. Smaller than most fume hoods, VS Stations, in 2', 3' and 4' widths, exhaust less tempered room air than traditional hoods to conserve energy. They have no switches, wiring or service fixtures that can add significant costs. Illumination is provided by room light. Protector VS Stations may be connected to a remote blower and exhausted to the outside. When connected to the VS Station, Protector FilterMate Mobile Stations provide an alternative to outside ducting. With a carbon-based and/or HEPA filter cell installed, the FilterMate rids the work area of fumes and vapors and/or hazardous particulates. No outside ducting is required. Tempered safety glass front sash, sides and top offer excellent visibility, light and protection making the VS Station well suited for teaching demonstrations. Glass provides better fire, scratch and corrosion resistance than acrylic. Sturdy glacier white, dry powder epoxy-coated aluminum frame provides excellent stability and better corrosion resistance than acrylic models. No unreliable plastic-toplastic bonding is used. Versatile exhaust openings allow connection from top or back. Lower static pressures allow smaller blower and quieter operation. Over-the-top by-pass offers additional flow and purging of vapors through the upper interior of the enclosure. Hinged sash swings up to provide 19" (48.3 cm) opening for loading and cleaning. Ergonomic angled sash allows a closer view, reduces glare and provides a more comfortable operating position than vertical sashes " sash opening to the work surface limits exhaust demand, conserves costly tempered air and requires a smaller blower than most fume hoods. Low profile design requires less space than most ventilated enclosures. Overall height is less than 23" (58.4 cm). Performance tested to ASHRAE Epoxy-coated steel baffle s unique slot pattern provides proper distribution of air being pulled through the enclosure to ensure uniform face velocity at the front opening and containment. Convenient utility ports allow passage of tubing and electrical cords from equipment inside the VS Station through the back for connection to services. Plastic plugs seal the ports when not in use. Aerodynamic air foil improves fume containment by reducing turbulence. Air foil swings up for cleaning. Exclusive Feature 77

81 Protector VS Ventilation Stations Ordering Information Protector VS Ventilation Station is shown with Solid Epoxy Work Surface and Telescoping Base Stand Blower, ductwork, work surface and base stand must be ordered separately. Nominal Catalog Total Exhaust CFM and Static Pressure Shipping Width Number 100 fpm S.P. 80 fpm S.P. 60 fpm S.P. Wt. lbs./kg 2 Feet " " 90.03" 50/28 3 Feet " " " 75/34 4 Feet " " " 100/45 All models feature: By-pass airflow design. Pivoting air foil. Glacier white, dry powder epoxy-coated aluminum frame and steel slotted baffle, plenum and air foil. Clear, 3/16" thick, tempered safety glass sides and top. 8 angled, 1/4" thick tempered safety glass sash that has working height opening of 10.25" to work surface and swings up to 19" for loading and cleaning. Two utility ports with plastic plugs. Epoxy-coated steel 2.25" x 10" ID top exhaust connection and 6.00" ID back exhaust connection. All models conform to the following regulations and standards: SEFA ASHRAE ANSI Z All models require (not included): Work Surface. See page 82. Base Stand or Cabinet. See pages Dimensional Data C L TOP TOP B B 2.25" x 10.00" Exhaust Collar 22.75" 22.38" 20.50" 28.00" SIDE If ducting to the outside, all models also require (not included): Remote Blower. See page 82. Ductwork. See page 82 and back pocket. If connecting to Protector FilterMate Mobile Station, all models also require (not included): Protector FilterMate Mobile Station. See page 79. Color-Smart Filter Cell(s). See pages Model A B 9.00" C L 10.25" to Work Surface 6.00" ID Exhaust Collar " 11.88" " 17.88" " 23.88" A FRONT FRONT 78

82 Protector FilterMate Mobile Stations Protector FilterMate Mobile Station All models feature: Glacier white, dry powder epoxy-coated steel exterior base with a gray formedthermoplastic filter housing cover. Four 2" diameter hard rubber casters. Built-in, non-sparking motor blower. Adjustable blower speed control. Foot-operated ON/OFF switch attached to a 4' cord. Roughing pre-filter to remove dust and other particulates, extending the life of the Color-Smart Filter Cell. The pre-filter may be omitted when using the HEPA Filter Cell only. 8 feet of 5" ID flexible duct; two clamps; and a glacier white, epoxy-coated steel transition adaptor. Right-angle transition adaptor fits on the Protector VS Ventilation Station s top exhaust opening, 2.25" x 10", so that it accepts 5" ID flexible duct. Air sampling syringe for test port. Thermoplastic 5" OD exhaust connection. All models conform to the following regulations and standards: UL / CAN/CSA C22.2 No CE Conformity Marking (230 volt model)* Ordering Information All models require (not included): Color-Smart Filter Cell(s). See pages Depending on the application, one each carbon-based or one each HEPA filter cell is required for operation. Or for combination gaseous and particulate applications, one each carbon-based and one each HEPA filter cell are required for operation. Two each carbon-based or two each HEPA filter cells may not be installed in the FilterMate at one time. Optional accessories (see page 82): Opening Reduction Kit for 3' Protector VS Ventilation Station. Increases face velocity when carbonbased filter cell is used. Replacement Roughing Prefilter. Electrostatic Prefilter. Catalog Description 9' Cord Shipping Number and Plug Weight lbs./kg Protector FilterMate Mobile Station, 115 volts, 45/ volts, 60 Hz, 2 amps 15 amps ** Protector FilterMate Mobile Station, 230 volts, 45/ volts, 50 Hz, 1 amp 10 amps, no plug ** International electrical configuration *pending Protector VS Protector VS Filter Cell(s) Face Velocity Opening Reduction Nominal Width Catalog # Used In FilterMate Range (fpm) Kit Required 2 Feet Single Carbon N/A Single HEPA N/A Carbon and HEPA N/A 3 Feet Single Carbon To achieve 100 fpm Single HEPA N/A Carbon and HEPA To achieve 90 fpm 4 Feet Single Carbon N/A Single HEPA N/A Carbon and HEPA N/A Dimensional Data 5.00" OD Exhaust Collar 26.75" 17.75" 27.88" 24.50" 23.25" Carbon/HEPA Filter Carbon Filter Only HEPA Filter Only FRONT SIDE 79

83 Color-Smart Filter Cells Color-Smart Ammonia Carbon-Based Filter Cells Color-Smart Filter Cells are engineered to the National Institute for Occupational Safety and Health (NIOSH) guidelines for respirators. Filters are color coded in the same way as respirator cartridge types for at-a-glance recognition. Four carbonbased Filter Cell types and two HEPA Filter Cell types are available: Application Matrix Organic Filter Cells, Type AC, are color coded black and are suitable for vapors from organic solvents including acetone, ethyl acetate, toluene and xylene. Acid Gas Filter Cells, Type ST-1, are color coded white and are suitable for fumes from acids including hydrochloric, nitric and sulfuric. Formaldehyde Filter Cells, Type CI, are color coded drab green and are suitable for vapors from formaldehyde. Ammonia Filter Cells, Type CX, are color coded bright green and are suitable for ammonia and low molecular weight amines. HEPA Filter Cells, 99.99% efficient, are color coded purple and are suitable for removing particulates such as powders and pollen. They should not be used to capture biohazardous materials or volatile organic material. Sealed HEPA Filter Cells, 99.99% efficient, available only for use with Protector FilterMate Mobile Stations, are color coded purple and are suitable for removing hazardous particulates such as drugs and dry chemicals. They include a bag out system for safe disposal of contaminated cells. They should not be used to capture biohazardous materials or volatile organic material. Below is an Application Matrix that provides examples of appropriate uses for Color-Smart Filter Cells expended in the Paramount and FilterMate. Whether or not the Paramount or FilterMate would be appropriate for your application requires consideration of factors such as the timeweighted exposure limits of your materials. Using Labconco s exclusive chemical assessment program, our technical specialists can help you determine if the Paramount Filtered Enclosure or Protector VS Ventilation Station with Protector Filter- Mate Mobile Station is the right ventilation product for your application and, if so, estimate filter life. 80 Filter Type All Paramount & FilterMate Models Duet & FilterMate Models FilterMate Configuration Organic Acid Gases Ammonia Formaldehyde Carbon*/HEPA HEPA/Carbon* HEPA** Acid pouring and mixing Asbestos handling Clean room/critical environment Combination dry and liquid chemicals Drug compounding/research Endoscopy instrument cleaning Histology/cytology tissue staining, coverslipping Histology/pathology Hormone research Non-biohazardous microbiological samples with trace chemicals Particulates in conjunction with chemical agents Pathology/tissue grossing Photo-engraving Plastics production Pollen handling Soldering Solvent cleaning Solvent welding/gluing Weighing chemical powders * Carbon filter type varies based on application Carbon-based filter cell is placed below the HEPA filter cell on the Paramount and above the HEPA filter cell on the FilterMate so that gaseous contaminants are removed first. HEPA filter cell is placed below the carbon-based filter cell on the Paramount and above the carbon-based filter cell on the FilterMate so that particulate contaminants are removed first. ** A single HEPA filter applies to the Protector FilterMate Mobile Station only. A Sealed HEPA Filter Cell is required if particulates captured by the filter are hazardous.

84 Color-Smart Filter Cells For use with Paramount Filtered Enclosures Each pair of Ammonia, Acid Gas and Formaldehyde Filter Cells includes three sampling tubes that detect a broad range of chemicals specific to the filter type. A color change indicates the presence of contaminants. Detector tubes more sensitive to the specific chemical in use may be necessary and are available from laboratory safety supply distributors. Due to the broad range of possible organic chemicals, detector tubes are not included with Organic Filter Cells; they should be purchased separately to suit your application. All Paramount models require one pair and all Paramount 72 models require two pairs of carbon-based Filter Cells. Catalog # Description Shipping Wt. lbs./kg Ammonia Carbon-Based Filter Cells, Type CX. Color-coded bright green. Each cell contains a minimum 90/41 of 26 pounds of impregnated carbon. 1 pair of Filter Cells. Includes 3 contaminant detector tubes Acid Gas Carbon-Based Filter Cells, Type ST-1. Color-coded white. Each cell contains a minimum of 26 pounds of impregnated carbon. 1 pair of Filter Cells. Includes 3 contaminant detector tubes. 90/ Organic Carbon-Based Filter Cells, Type AC. Color-coded black. Each cell contains a minimum of 90/41 26 pounds of activated carbon. 1 pair of Filter Cells Formaldehyde Carbon-Based Filter Cells, Type CI. Color-coded drab green. Each cell contains a minimum 90/41 of 26 pounds of impregnated carbon. 1 pair of Filter Cells. Includes 3 contaminant detector tubes HEPA Filter Cells, 99.99% efficient. Color-coded purple. Suitable for removing 0.3 micron particulates. 1 pair of Filter Cells. One pair is required for Paramount Duet models and two pairs are required for Paramount Duet 72 models. 90/41 For use with Protector FilterMate Mobile Stations Each Ammonia, Acid Gas and Formaldehyde Filter Cell includes three sampling tubes that detect a broad range of chemicals specific to the filter type. A color change indicates the presence of contaminants. Detector tubes more sensitive to the specific chemical in use may be necessary and are available from laboratory safety supply distributors. Due to the broad range of possible organic chemicals, detector tubes are not included with Organic Filter Cells; they should be purchased separately to match your chemical use. Depending on the application, one each carbonbased or one each HEPA filter cell is required for operation. Or for combination gaseous and particulate applications, one each carbon-based and one each HEPA filter cell are required for operation. Two each carbon-based or two each HEPA filter cells may not be installed in the FilterMate at one time. Catalog # Description Shipping Wt. lbs./kg Ammonia Carbon-Based Filter Cell, Type CX. Color-coded bright green. Contains a minimum of 26 pounds of impregnated carbon. Includes 3 contaminant detector tubes. 45/ Acid Gas Carbon-Based Filter Cell, Type ST-1. Color-coded white. Contains a minimum of 26 pounds of impregnated carbon. Includes 3 contaminant detector tubes. 45/ Organic Carbon-Based Filter Cell, Type AC. Color-coded black. Contains a minimum of 26 pounds of activated carbon. 45/ Formaldehyde Carbon-Based Filter Cell, Type CI. Color-coded drab green. Contains a minimum of 26 pounds of impregnated carbon. Includes 3 contaminant detector tubes. 45/ HEPA Filter Cell, 99.99% efficient. Color-coded purple. Suitable for removing 0.3 micron particulates. 45/ Sealed HEPA Filter Cell, 99.99% efficient. Color-coded purple. Suitable for removing 0.3 micron particulates. Includes bag out system for safe disposal of contaminated filter cell. 45/20 Replacement Detector Tubes Catalog Description Shipping Number Weight lbs./kg Ammonia Detector Tubes, package of / Acid Gas Detector Tubes, package of / Formaldehyde Detector Tubes, package of /0.2 81

85 Accessories Protector VS Ventilation Stations & Protector FilterMate Mobile Stations Solid Epoxy Work Surfaces Gray work surfaces are contoured to fit the dimensions of Protector VS Ventilation Stations and dished to contain spills. Solid epoxy is chemical resistant and fire proof. Catalog # Nominal Dimensions Shipping Width Wt. lbs./kg Feet 24.00" w x 25.50" d x.75" thick 40/ Feet 36.00" w x 25.50" d x.75" thick 60/ Feet 48.00" w x 25.50" d x.75" thick 80/36 Remote Blowers 1/4 hp direct drive motor. Corrosion-resistant epoxy-coated steel housing and wheel. Blower inlet is 6.00" ID. Outlet dimensions are 4.25" x 7.38" OD. See dimensional data on page 90. Static Pressure Inches of H 2 O S.P. 0.0" 0.125" 0.25" 0.50" 0.75" 0.87" CFM Catalog # Description Shipping Wt. lbs./kg Remote Blower, 115 volts, 60 Hz, 4.4 amps 35/ Remote Blower, 115/230 volts, 50 Hz, 5.6/2.8 amps 35/ Explosion-Proof Remote Blower, 40/ volts, 60 Hz, 4.4 amps Ductwork Epoxy-coated steel Adaptors provide easy connection to nominal 6" diameter PVC duct. Flexible Duct Connection reduces vibration between the blower and ductwork and includes two clamps. See Ducting Options below. Catalog # Description Exhaust Shipping Wt. lbs./kg Transition Adaptor, 6" diameter From back 2/1 round, without damper Transition Adaptor, 6" diameter From back 2/1 round, with damper Transition Adaptor, 2.25" x 10.00" From top 2/1 rectangle to 6" diameter round Blower Transition Adaptor, From top 3/1 4.25" x 7.75" rectangle to 6" diameter round Flexible Duct Connection N/A 5/2 for 6" diameter duct Opening Reduction Kit Installs on 3' Protector VS Ventilation Station to reduce the sash opening height from 9.00" to 7.50". Reducing the sash opening helps to increase face velocity and is necessary when a single carbonbased filter or combination carbon-based/hepa filter is used in the Protector FilterMate Mobile Station. Shipping weight 2 lbs. (0.9 kg) Replacement Roughing Prefilter Removes dust and other particulates, extending the life of Color-Smart Filter Cells. Labconco recommends replacing prefilters whenever changing Color-Smart Filter Cells. 1 each. Shipping weight 1.5 lbs. (0.7 kg) Electrostatic Prefilter Removes mist and fine particles, extending the life of Color-Smart Filter Cells. These optional prefilters are used in place of Roughing Prefilters for removal of aerosols. 1 each. Shipping weight 1.5 lbs. (0.7 kg) Ducting Options Remote Blower Zero Pressure Weathercap Blower Transition Adaptor Zero Pressure Weathercap Blower Transition Adaptor Flexible Duct Connection Flexible Duct Connection Elbow Elbow Thermoplastic Duct Remote Blower Thermoplastic Duct Elbow Thermoplastic Duct Transition Adaptor or Transition Adaptor (Female Duct Coupling is not depicted in drawings) 82

86 Demonstration Hood Demonstration Hood is shown with Variable Height Bench Base must be ordered separately. Demonstration Hood provides a clear, unobstructed view of experiments from all sides. It is designed for classroom and other applications requiring close observation of procedures. For true portability, the lightweight hood may be installed on a mobile base and transported from lab to lab. Outside ducting is required. Ordering Information: Catalog # Features: Quiet built-in blower that provides 94 CFM (45 fpm). Retractable 3/16" thick tempered safety glass front shield to improve face velocity and protect the operator. 3/16" thick tempered safety glass side walls. Glacier white, dry powder epoxycoated tubular steel side posts. High-impact thermoplastic canopy. Chemical-resistant, plastic laminate work surface. Pre-wired 100-watt, vapor-proof incandescent light bulb and fixture, switch and 8-foot 3-wire cord with plug for 115 volt, 60 Hz operation. 2" diameter exhaust connection. Shipping weight 99 lbs. (45 kg) Required accessories: Ductwork. Shown at right. Supporting Base. Shown at right. Accessories Flexible Exhaust Duct 42" length of 2" diameter steel-reinforced vinyl duct with two clamps. Shipping weight 2 lbs. (0.9 kg) Flexible Exhaust Duct 10' length of 2" diameter steel-reinforced vinyl duct with 2 clamps. Shipping weight 6 lbs. (2.7 kg) Duct Outlet Quick connect fitting joins Flexible Exhaust Duct, above, to wall or Duct Inlet Valve, below. Shipping weight 1 lb. (0.45 kg) Duct Inlet Valve Valve with cover connects Duct Outlet, above, with exhaust system. Shipping weight 2 lbs. (0.9 kg) Variable Height Bench Dimensional Data 20.75" 1.75" 9.5" 2" EXHAUST DUCT CONNECTION 21" 29" 9.25" Mobile bench provides movable support for Demonstration Hood. Height may be adjusted from 29.63" to 37.38". Five-inch diameter, non-marking polyurethane casters with toe locks. Glacier white. Epoxy-coated tubular steel construction with laminate work surface. Work surface is 38" w x 28" d. Holds loads up to 540 lbs. Shipping weight 111 lbs. (50.3 kg) 32" OPENING 37" FRONT 20" OPENING 25" SIDE 83

87 Canopy Hoods Nominal Catalog Shipping Width Number Weight lbs./kg 4 Feet /29 6 Feet /45 4' Canopy Hood CFM at Static Pressure Inches H 2 O.12".19".22".36".39".73" 2.45" ' Canopy Hood CFM at Static Pressure Inches H 2 O.17".24".31".45".49".89" 2.5" Dimensional Data 30" 8" 4' MODEL 10.81" ID 6' MODEL 12.81" ID 2" Canopy Hood Blower and ductwork must be ordered separately. 18" The Canopy Hood is specifically designed to vent non-toxic materials such as heat, steam and odors from large or bulky apparatus such as ovens, steam baths and autoclaves. The hood may be installed on a wall or suspended from the ceiling for peninsular and corner locations. For most efficient performance, the hood should be installed no more than 12" above the equipment to be ventilated. Coupled with a blower and ductwork, the Canopy Hood can operate at a wide range of exhaust rates. Features: Glacier white, dry powder epoxy-coated steel construction. Integral baffle. Fully assembled, complete with mounting hardware for installation on wall or suspended from ceiling. Threaded rod is required. Both models require (not included): Remote Blower. See back pocket. Ductwork. See back pocket. SIDE 4' MODEL 48" 6' MODEL 72" FRONT 84

88 Fume Adsorbers Fume Adsorber offers twice the work space. Fume Adsorber is shown positioned vertically. Fume Adsorber is shown with Flat Solid Epoxy Work Surface and Protector Solvent Storage Cabinet Work surface and base cabinet must be ordered separately.. Designed for light duty histology coverslipping and staining areas, Fume Adsorbers use activated carbon to adsorb organic odors and noxious vapors such as xylene and toluene.* OSHA has set the limit for employee exposure to xylene and toluene at 100 parts per million over an eight hour work day. When operated as directed, the Fume Adsorber lowers xylene and toluene concentrations below this level. Solvent vapors are trapped in the capillary-like channels of the carbon filter while clean air is recirculated into the laboratory. Fume Adsorbers require no ducting to the outside and are completely portable. Fume Adsorbers fit easily on countertops with overhanging cabinets. They can also be placed with the housing on top to accommodate shallow countertops. Fume Adsorbers are available in two widths Fume Adsorber 27.63" wide x 20.38" deep x 12.25" high. For operation on 115 volts, 50/60 Hz, 1 amp. Built-in blower with brushless motor provides face velocity of 25 fpm (55 CFM). Adsorber includes one replaceable 6 pound Type AC activated carbon filter, 26" w x 10.5" h, to adsorb organic vapors such as xylene and toluene. The filter adsorbs up to 1/3 of its own weight in organic vapors. Blower and carbon filter are housed in a glacier white, dry powder epoxy-coated steel cell, which is louvered in front for efficient airflow. Enclosure is clear, one-piece, shatterresistant acrylic, 3/8" thick. Includes wiring, switch and an 8-foot, three-wire cord with plug. Shipping weight 51 lbs. (23 kg) Fume Adsorber** Same as except for operation on 230 volts, 50/60 Hz, 0.5 amp. Requires an electrical plug (not included) Fume Adsorber " wide x 20.38" deep x 12.25" high. For operation on 115 volts, 50/60 Hz, 2 amps. Two built-in blowers with brushless motors provide face velocity of 25 fpm (110 CFM). Adsorber includes two replaceable 6 pound Type AC activated carbon filters, 26" w x 10.5" h, to adsorb organic vapors such as xylene and toluene. Each filter adsorbs up to 1/3 of its own weight in organic vapors. Blowers and carbon filters are housed in a glacier white, dry powder epoxy-coated steel cell, which is louvered in front for efficient airflow. Enclosure is clear, one-piece, shatterresistant acrylic, 3/8" thick. Includes wiring, switch and an 8-foot, three-wire cord with plug. Shipping weight 103 lbs. (47 kg) Fume Adsorber-2** Same as except for operation on 230 volts, 50/60 Hz, 1 amp. Requires an electrical plug (not included) Replacement Carbon Filter Pillow has six pounds of Type AC activated charcoal filter media, 26" w x 10.5" h. Models and use one filter; models and use two filters. One each. Shipping weight 9 lbs. (4 kg) * Chemical assessment is recommended. ** International electrical configuration 85

89 Protector Work Station is shown on Work Surface with Sink and Telescoping Base Stand Inset: Protector Work Station is shown with Flat Work Surface and Protector Solvent Storage Cabinet

90 Protector Work Stations Features & Benefits Protector Work Stations are specifically designed for the needs of pathologists and histotechnologists. Like a traditional fume hood, these enclosures have a front air foil and rear baffle to direct the inflow air across the work area and away from the operator. Ideal for cramped or crowded labs, Protector Work Stations have a low profile so they fit easily under standard upper cabinets. Protector Work Stations designed for ducting to the outside are available with or without a built-in blower. If there is no feasible way to vent to the outside, models with a built-in blower are available that use specially treated carbon filters. These filter packs keep low level concentrations of toluene, xylene, formalin, formaldehyde and other solvents below their OSHA-recommended, time-weighted averages, restoring clean air to the laboratory. Fluorescent lamp with on-off switch floods the area with light. The flat top can accommodate other supplies such as dictation equipment. Durable and attractive top and back are dry powder epoxy-coated steel. Low-profile 24" height fits under most standard upper cabinets. Efficient airflow of 50 fpm face velocity contains and dilutes hazardous chemical vapors. Optional built-in blower (Models , and ) where permitted, eliminates the need for a roof-mounted blower if your 6" diameter duct run does not exceed 140 equivalent feet. Hinged tempered safety glass sash protects the technician, provides a 10" working height from the work surface and swings up to 19" for loading and cleaning. Curved air foil sweeps air flow across the work surface to contain fumes. It is easily removable for cleaning. Type 304 stainless steel baffle (Model ) adjusts to provide even airflow when ducting from either side. Louvered Type 304 stainless steel grille unfastens for easy cleaning. On models with filters, the grille provides easy access for filter changes. Hardboard side walls are laminated with glacier white phenolic/melamine for durability. Optional Work Surface of solid black epoxy is corrosion and stain resistant. It is supplied with a corrosionresistant, chrome-plated gooseneck fixture with vacuum breaker and two faucet controls. A retractable hose with spray nozzle speeds clean-up. Exclusive Feature 87

91 Protector Work Stations Protector Work Station is shown with Flat Work Surface and Protector Solvent Storage Cabinet Ductwork, work surface and base cabinet must be ordered separately. Protector Work Station is shown on Work Surface with Sink and Telescoping Base Stand Ductwork, work surface and base stand must be ordered separately. All models feature: Aerodynamic air foil that is removable for cleaning. Glacier white, phenolic/melamine laminated hardboard side walls. Dry powder epoxy-coated steel air foil, top and back. Type 304 stainless steel grille with baffle. Clear, 1/4" thick, tempered safety glass hinged sash to provide a working height opening of 10". Sash swings up to an access opening height of 19". Pre-wired 30-watt fluorescent light and light switch. Interior working depth of 13.75". All models conform to the following regulations and standards: UL / CAN/CSA C22.2 No Model features: Designed to duct to the outside. Built-in blower that draws 3 amps and is capable of overcoming external static pressure loss of.33" H 2 O at 50 fpm (167 CFM). Pre-wired for operation on 115 volts, 60 Hz, 15 amps. 8', three-wire cord with plug. 6" x 6" square to 6" diameter round adaptor for connection to the exhaust system. Model features: Designed for use with carbon filters (not included). Outside ducting not required. Built-in blower that draws 3 amps and provides 50 fpm face velocity. Pre-wired for operation on 115 volts, 60 Hz, 15 amps. 8', three-wire cord with plug. Model features: Designed to duct to the outside from one of four exhaust connections. For use with remote blower (not included). Adjustable baffle. Pre-wired for operation on 115 volts, 60 Hz, 15 amps. 8', three-wire cord with plug. Three each 3.25" x 10" exhaust connections located on the top and both sides. 6" nominal diameter exhaust connection located on the back. Static pressure loss does not exceed.28" H 2 O at 50 fpm (167 CFM). Model features: Designed for use with carbon filters (not included). Outside ducting not required. Built-in blower that draws 2 amps and provides 50 fpm face velocity. Pre-wired for operation on 220 volts, 50 Hz, 7 amps. 8', three-wire cord. An electrical plug is required. All models require (not included): 4' Work Surface. See pages 88 and 104. Base Stand or Cabinet. See pages Model also requires (not included): Ductwork. See back pocket. Models and also require (not included): Carbon Filter Packs. See page 90. Model also requires (not included): Transition Adaptor and Ductwork. See page 91 and back pocket. Remote Blower. See page

92 Ordering Information & Dimensional Data Protector Work Stations Ordering Information Nominal Catalog Static Carbon Shipping Width Number Blower Pressure Loss Filters Weight lbs./kg 4 Feet Built-in, Blower overcomes external static pressure loss of Not used 114/ volts, 60 Hz.33" H 2 O at 50 fpm (167 CFM).* Built-in, Blower overcomes external static pressure loss of Required 114/ volts, 60 Hz.33" H 2 O at 50 fpm (167 CFM).* (see page 90) Requires remote blower Does not exceed.28" H 2 O at 167 CFM (50 fpm) Not used 93/ ** Built-in Blower overcomes external static pressure loss of Required 114/ volts, 50 Hz.33" H 2 O at 50 fpm (167 CFM).* (see page 90) * Equivalent resistance of 140 feet of 6" diameter straight duct ** International electrical configuration 4.875" 6" dia. duct adaptor models without carbon filter " Models , and " 10" 20.5" 15.38" 13.75" 47.75" TOP 59.75" 12" 6".25" 22.31" SIDE 23.5" 10" to Work Surface " 46.5" FRONT Opening for 3.75" x 10" duct Models " 10" 15.38" 13.75" 47.75" TOP Opening for 6" duct 22.31" SIDE 23.5" 10" to Work Surface 18" 46.5" FRONT 89

93 Accessories Protector Work Stations Carbon Filter Packs for Models and Adsorb harmful chemical fumes. Whether or not the Protector Work Station with Carbon Filters would be appropriate for your application requires consideration of factors such as the time-weighted exposure limits of your materials. Using Labconco s exclusive chemical assessment program, our technical specialists can help you determine if it is the right ventilation product for your application and, if so, estimate filter life. Filter packs are available in two formulations: (1) for applications involving xylene, toluene or other organic solvents only. (2) for applications involving formalin and formaldehyde as well as xylene, toluene or other organic solvents. Catalog # Description Shipping Wt. lbs./kg Organic Filter Pack, Type AC, includes two activated carbon filters for 32/15 adsorbing xylene, toluene or other organic solvents. Each filter contains 15 pounds of media * Organic/Formaldehyde Filter Pack includes one activated carbon filter, 32/15 Type AC, for adsorbing xylene and toluene and one specially treated filter, Type CI, for adsorbing formalin and formaldehyde. Each filter contains 15 pounds of media. *If you are NOT using formalin and formaldehyde, order only. Remote Blowers for Model Sized to meet the air volume requirements of the Protector Work Station. 1/4 hp direct drive motor. Corrosion-resistant, enamel-coated steel housing and wheel. Discharge direction is adjustable to accommodate unusual blower locations. Blower inlet is 6" OD. Outlet dimension is 4.25" x 7.38" OD. Dimensional Data ( , , , ) 3.13" 10.13" 1.25" 5" 6" 4" 5" 6" OD 8.25" 7.38" 7.13" 4.25" 7" 8".50" 4.25" 4.25" 9.38".38" DIA. 4 HOLES Catalog # Description Shipping Wt. lbs./kg Remote Blower, 115 volts, 60 Hz, 4.4 amps 35/ Explosion-Proof Remote Blower, 40/ volts, 60 Hz, 4.4 amps Static Pressure Inches of H 2 O S.P. 0.0" 0.125" 0.25" 0.50" 0.75" 0.87" CFM

94 Accessories Protector Work Stations Transition Adaptors for Model Model may be exhausted from the top, sides or back. These epoxy-coated steel transition adaptors connect to standard 6" diameter duct. Ducting Exhaust Catalog# Description Shipping Options Wt. lbs./kg From back 6" dia. round adaptor 2/1 without damper From back 6" diameter round adaptor 2/1 with damper with damper From top 3.25" x 10" to 6" diameter round 2/ From left side 3.25" x 10" to 6" diameter round 2/ From right side 3.25" x 10" to 6" diameter round 2/ From back, right end 3.25" x 10" to 6" diameter 90 elbow 2/ From back, left end 3.25" x 10" to 6" diameter 90 elbow 2/1 Ducting Options 3 3" 4, 5, 6 OR 7 1 OR 2 4" 1 OR 2 3" 7" 6" 5" 29.50" 4 OR 5 (OPPOSITE END) 6 OR 7 (OPPOSITE END) 18.00" 17.13" 17.13" TOP SIDE FRONT SIDE Work Surface with Sink Fabricated from durable epoxy resins, this unique work surface is designed to accept standard dissecting boards and is dished to contain spills. It resists corrosion and will not stain or absorb liquids. Easy to clean, the work surface comes with a 10" x 14" x 6" deep molded epoxy sink. Fixtures include a chrome-plated gooseneck faucet with vacuum breaker, two chrome-plated faucet controls, and a spray nozzle with hose. Sink requires a 1.5" drain connection. 48" w x 24" d x 1.25" thick. Shipping weight 115 lbs. (52 kg). This work surface may be mounted on Telescoping Base Stand or described on page " 48" 6.6" 14.5" 24" 3.5" 3.5" faucet controls TOP 9.75" 3" Spray hose with nozzle work surface gooseneck faucet 1.25" 6.5" FRONT 11" 4.38" 15" 7" SIDE 91

95 SpillStopper Work Surfaces SpillStopper Work Surface for use with 4' Protector Premier and XL Laboratory Hoods Features: Molded from a special formulation of 1.25" thick corrosion-resistant epoxy resins. Dished and contoured to conform to the interior liner of Protector Laboratory Hoods. Front edge has a large radius to aerodynamically direct airflow into the hood. Pre-drilled 1.5" diameter holes for venting and 2.5" diameter holes for plumbing passthrough. May be ordered with a pre-drilled 6" x 3" oval cupsink cutout. Cupsink is sold separately. See page 95. Surface for use with 6' Protector ClassMate Laboratory Hoods. See page 95 for Ordering Information and Dimensional Data. Dimensional Data SpillStopper Work Surfaces for Use with Protector Premier, XStream and XL Laboratory Hoods 2.28" Typ A 1.50" Hole Typ - 2 Places 3.64" Typ B 4.87" Hood Work Surface A B C Radius Depth Front Edge C Premier, XL 30" 9.50" 5.81" 20.00" 1.00" XL 36" 12.50" 8.50" 20.00" 1.00" XL 42" 12.50" 8.50" 16.12" 1.00"* XL HOPEC IV 31.50" 12.50" 8.50" 20.00" 0.50" 4.94" 3.50" 4.94" XStream 36" 12.50" 11.50" 20.00" 1.00" * Contact Labconco for availability. 7.75" TOP 1.25".38" Dish FRONT Radiused Front Edge Only SIDE 92

96 SpillStopper Work Surfaces Oval Sink Cutout Left Rear Oval Sink Cutout Left Side Oval Sink Cutout Right Side Oval Sink Cutout Right Rear For use with Protector Premier and XL Laboratory Hoods with 24" interior depth Catalog # Description Shipping Wt. lbs./kg ' w x 30" d, no cutouts 110/ ' w x 30" d, sink cutout, left rear 110/ ' w x 30" d, sink cutout, right rear 110/ * 4' w x 30" d, sink cutout, left side 110/ * 4' w x 30" d, sink cutout, right side 110/ ' w x 30" d, sink cutouts, left and right rear 110/ ' w x 30" d, no cutouts 150/ ' w x 30" d, sink cutout, left rear 150/ ' w x 30" d, sink cutout, right rear 150/ * 5' w x 30" d, sink cutout, left side 150/ * 5' w x 30" d, sink cutout, right side 150/ ' w x 30" d, sink cutouts, left and right rear 150/ ' w x 30" d, no cutouts 205/ ' w x 30" d, sink cutout, left rear 205/ ' w x 30" d, sink cutout, right rear 205/ * 6' w x 30" d, sink cutout, left side 205/ * 6' w x 30" d, sink cutout, right side 205/ ' w x 30" d, sink cutouts, left and right rear 205/ ' w x 30" d, no cutouts 240/ ' w x 30" d, sink cutout, left rear 240/ ' w x 30" d, sink cutout, right rear 240/ * 8' w x 30" d, sink cutout, left side 240/ * 8' w x 30" d, sink cutout, right side 240/ ' w x 30" d, sink cutouts, left and right rear 240/ ' w x 30" d, two pieces, no cutouts 290/ ' w x 30" d, two pieces, sink cutout, left rear 290/ ' w x 30" d, two pieces, sink cutout, right rear 290/ * 10' w x 30" d, two pieces, sink cutout, left side 290/ * 10' w x 30" d, two pieces, sink cutout, right side 290/ ' w x 30" d, two pieces, 290/132 sink cutouts, left and right rear ' w x 30" d, two pieces, no cutouts 370/ ' w x 30" d, two pieces, sink cutout, left rear 370/ ' w x 30" d, two pieces, sink cutout, right rear 370/ * 12' w x 30" d, two pieces, sink cutout, left side 370/ * 12' w x 30" d, two pieces, sink cutout, right side 370/ ' w x 30" d, two pieces, 370/168 sink cutouts, left and right rear ' w x 30" d, three pieces, no cutouts 480/ ' w x 30" d, three pieces, sink cutout, left rear 480/ ' w x 30" d, three pieces, sink cutout, right rear 480/ * 16' w x 30" d, three pieces, sink cutout, left side 480/ * 16' w x 30" d, three pieces, sink cutout, right side 480/ ' w x 30" d, three pieces, 480/218 sink cutouts, left and right rear For use with Protector XL Laboratory Hoods with 30" interior depth Catalog # Description Shipping Wt. lbs./kg ' w x 36" d, sink cutout, no cutouts 120/ ' w x 36" d, sink cutout, left rear 120/ ' w x 36" d, sink cutout, right rear 120/ * 4' w x 36" d, sink cutout, left side 120/ * 4' w x 36" d, sink cutout, right side 120/ ' w x 36" d, sink cutouts, left and right rear 120/ ' w x 36" d, no cutouts 160/ ' w x 36" d, sink cutout, left rear 160/ ' w x 36" d, sink cutout, right rear 160/ * 5' w x 36" d, sink cutout, left side 160/ * 5' w x 36" d, sink cutout, right side 160/ ' w x 36" d, sink cutouts, left and right rear 160/ ' w x 36" d, no cutouts 220/ ' w x 36" d, sink cutout, left rear 220/ ' w x 36" d, sink cutout, right rear 220/ * 6' w x 36" d, sink cutout, left side 220/ * 6' w x 36" d, sink cutout, right side 220/ ' w x 36" d, sink cutouts, left and right rear 220/ ' w x 36" d, no cutouts 250/ ' w x 36" d, sink cutout, left rear 250/ ' w x 36" d, sink cutout, right rear 250/ * 8' w x 36" d, sink cutout, left side 250/ * 8' w x 36" d, sink cutout, right side 250/ ' w x 36" d, sink cutouts, left and right rear 250/ ' w x 36" d, two pieces, no cutouts 320/ ' w x 36" d, two pieces, sink cutout, left rear 320/ ' w x 36" d, two pieces, sink cutout, right rear 320/ * 10' w x 36" d, two pieces, sink cutout, left side 320/ * 10' w x 36" d, two pieces, sink cutout, right side 320/ ' w x 36" d, two pieces, 320/145 sink cutouts, left and right rear ' w x 36" d, two pieces, no cutouts 440/ ' w x 36" d, two pieces, sink cutout, left rear 440/ ' w x 36" d, two pieces, sink cutout, right rear 440/ * 12' w x 36" d, two pieces, sink cutout, left side 440/ * 12' w x 36" d, two pieces, sink cutout, right side 440/ ' w x 36" d, two pieces, 440/200 sink cutouts, left and right rear ' w x 36" d, three pieces, no cutouts 500/ ' w x 36" d, three pieces, sink cutout, left rear 500/ ' w x 36" d, three pieces, sink cutout, right rear 500/ * 16' w x 36" d, three pieces, sink cutout, left side 500/ * 16' w x 36" d, three pieces, sink cutout, right side 500/ ' w x 36" d, three pieces, 500/228 sink cutouts, left and right rear * Not for use with Protector Solvent Storage Cabinets Requires field assembly 93

97 SpillStopper Work Surfaces Oval Sink Cutout Left Rear Oval Sink Cutout Left Side Oval Sink Cutout Right Rear Oval Sink Cutout Right Side For use with Protector XL Laboratory Hoods with 36" interior depth Catalog # Description Shipping Wt. lbs./kg ' w x 42" d, no cutouts 140/ ' w x 42" d, sink cutout, left rear 140/ ' w x 42" d, sink cutout, right rear 140/ * 4' w x 42" d, sink cutout, left side 140/ * 4' w x 42" d, sink cutout, right side 140/ ' w x 42" d, sink cutouts, left and right rear 140/ ' w x 42" d, no cutouts 180/ ' w x 42" d, sink cutout, left rear 180/ ' w x 42" d, sink cutout, right rear 180/ * 5' w x 42" d, sink cutout, left side 180/ * 5' w x 42" d, sink cutout, right side 180/ ' w x 42" d, sink cutouts, left and right rear 180/ ' w x 42" d, no cutouts 250/ ' w x 42" d, sink cutout, left rear 250/ ' w x 42" d, sink cutout, right rear 250/ * 6' w x 42" d, sink cutout, left side 250 / * 6' w x 42" d, sink cutout, right side 250/ ' w x 42" d, sink cutouts, left and right rear 250/ ' w x 42" d, no cutouts 290/ ' w x 42" d, sink cutout, left rear 290/ ' w x 42" d, sink cutout, right rear 290/ * 8' w x 42" d, sink cutout, left side 290/ * 8' w x 42" d, sink cutout, right side 290/ ' w x 42" d, sink cutouts, left and right rear 290/ ' w x 42" d, two pieces, no cutouts 350/ ' w x 42" d, two pieces, sink cutout, left rear 350/ ' w x 42" d, two pieces, sink cutout, right rear 350/ * 10' w x 42" d, two pieces, sink cutout, left side 350/ * 10' w x 42" d, two pieces, sink cutout, right side 350/ ' w x 42" d, two pieces, 350/159 sink cutouts, left and right rear ' w x 42" d, three pieces, no cutouts 480/ ' w x 42" d, three pieces, sink cutout, left rear 480/ ' w x 42" d, three pieces, sink cutout, right rear 480/ * 12' w x 42" d, three pieces, sink cutout, left side 480/ * 12' w x 42" d, three pieces, sink cutout, right side 440/ ' w x 42" d, three pieces, 480/218 sink cutouts, left and right rear ' w x 42" d, three pieces, no cutouts 550/ ' w x 42" d, three pieces, sink cutout, left rear 550/ ' w x 42" d, three pieces, sink cutout, right rear 550/ * 16' w x 42" d, three pieces, sink cutout, left side 550/ * 16' w x 42" d, three pieces, sink cutout, right side 550/ ' w x 42" d, three pieces, 550/249 sink cutouts, left and right rear For use with Protector XL HOPEC IV Laboratory Hoods Catalog # Description Shipping Wt. lbs./kg HOPEC, 4' w x 31.5" d, no cutouts 105/ HOPEC, 4' w x 31.5" d, sink cutout, left rear 105/ HOPEC, 4' w x 31.5" d, sink cutout, right rear 105/ * HOPEC, 4' w x 31.5" d, sink cutout, left side 105/ * HOPEC, 4' w x 31.5" d, sink cutout, right side 105/ HOPEC, 4' w x 31.5" d, sink cutouts, left and right rear 105/ HOPEC, 5' w x 31.5" d, no cutouts 140/ HOPEC, 5' w x 31.5" d, sink cutout, left rear 140/ HOPEC, 5' w x 31.5" d, sink cutout, right rear 140/ * HOPEC, 5' w x 31.5" d, sink cutout, left side 140/ * HOPEC, 5' w x 31.5" d, sink cutout, right side 140/ HOPEC, 5' w x 31.5" d, sink cutouts, left and right rear 140/ HOPEC, 6' w x 31.5" d, no cutouts 192/ HOPEC, 6' w x 31.5" d, sink cutout, left rear 192/ HOPEC, 6' w x 31.5" d, sink cutout, right rear 192/ * HOPEC, 6' w x 31.5" d, sink cutout, left side 192/ * HOPEC, 6' w x 31.5" d, sink cutout, right side 192/ HOPEC, 6' w x 31.5" d, sink cutouts, left and right rear 192/ HOPEC, 8' w x 31.5" d, no cutouts 220/ HOPEC, 8' w x 31.5" d, sink cutout, left rear 220/ HOPEC, 8' w x 31.5" d, sink cutout, right rear 220/ * HOPEC, 8' w x 31.5" d, sink cutout, left side 220/ * HOPEC, 8' w x 31.5" d, sink cutout, right side 220/ HOPEC, 8' w x 31.5" d, sink cutouts, left and right rear 220/100 For use with Protector XStream Laboratory Hoods Catalog # Description Shipping Wt. lbs./kg ' w x 36" d, no cutouts 120/ ' w x 36" d, sink cutout, left rear 120/ ' w x 36" d, sink cutout, right rear 120/ * 4' w x 36" d, sink cutout, left side 120/ * 4' w x 36" d, sink cutout, right side 120/ ' w x 36" d, sink cutouts, left and right rear 120/ ' w x 36" d, no cutouts 160/ ' w x 36" d, sink cutout, left rear 160/ ' w x 36" d, sink cutout, right rear 160/ * 5' w x 36" d, sink cutout, left side 160/ * 5' w x 36" d, sink cutout, right side 160/ ' w x 36" d, sink cutouts, left and right rear 160/ ' w x 36" d, no cutouts 220/ ' w x 36" d, sink cutout, left rear 220/ ' w x 36" d, sink cutout, right rear 220/ * 6' w x 36" d, sink cutout, left side 220/ * 6' w x 36" d, sink cutout, right side 220/ ' w x 36" d, sink cutouts, left and right rear 220/ ' w x 36" d, no cutouts 250/ ' w x 36" d, sink cutout, left rear 250/ ' w x 36" d, sink cutout, right rear 250/ * 8' w x 36" d, sink cutout, left side 250/ * 8' w x 36" d, sink cutout, right side 250/ ' w x 36" d, sink cutouts, left and right rear 250/113 * Not for use with Protector Solvent Storage Cabinets Requires field assembly 94

98 SpillStopper Work Surfaces & Accessories Oval Sink Cutout Left Rear Oval Sink Cutout Right Rear A B C D E For use with Protector ClassMate Laboratory Hoods Catalog # Description Shipping Wt. lbs./kg " w x 25.9" d, no cutouts 110/ " w x 25.9" d, sink cutout, left rear 110/ " w x 25.9" d, sink cutout, right rear 110/ " w x 25.9" d, sink cutouts, left and right rear 110/ " w x 25.9" d, no cutouts 150/ " w x 25.9" d, sink cutout, left rear 150/ " w x 25.9" d, sink cutout, right rear 150/ " w x 25.9" d, sink cutouts, left and right rear 150/ " w x 25.9" d, no cutouts 205/ " w x 25.9" d, sink cutout, left rear 205/ " w x 25.9" d, sink cutout, right rear 205/ " w x 25.9" d, sink cutouts, left and right rear 205/93 Dimensional Data 20.38" 3.00".50" 2.25" 1.25" 5.06" 1.25" 6.62" TOP.25" Dish 2.25" 2.50" 1.00" 25.88" (A) (A) (B) (C) (C) (D) (E) Cold Water Faucet with Rigid Gooseneck Factory-drilled mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) Cold Water Faucet with Rigid Gooseneck and Vacuum Breaker Factory-drilled mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) Oval Polypropylene Cupsink Mounts in work surface with cutout. 3" x 6". 1.5" NPSM** thread. Shipping weight 4 lbs. (1.8 kg) Trap, Lead 1.5" diameter drum with coupling nut. For use with cupsink. Shipping weight 10 lbs. (4.5 kg) Trap, PVC 1.5" diameter drum with coupling nut. For use with cupsink. Shipping weight 10 lbs. (4.5 kg) Sepia Bronze-Coated Cold and Hot Water Mixing Faucet with Swivel Gooseneck Not shown. Factorydrilled mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) Chrome-Plated Cold and Hot Water Mixing Faucet with Swivel Gooseneck Not shown. Factory-drilled mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) Service Fixture Specify air, gas or vacuum. Factory-drilled mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) Electrical Receptacle Pedestal-type, 115 volt, 15 amp duplex. Factory-drilled mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) Flat Solid Epoxy Work Surfaces For Use with Labconco Hoods including Fiberglass 30 and Basic Laboratory Hoods* FRONT SIDE 0.25" Radiused Front Edge Only Catalog # Description Shipping Wt. lbs./kg " w x 30" d x 1.25" thick, no cutouts 86/ " w x 30" d x 1.25" thick, no cutouts 90/ " w x 30" d x 1.25" thick, no cutouts 110/ " w x 30" d x 1.25" thick, no cutouts 205/93 * Basic Hoods are not as wide or as deep as the work surfaces that support them. ** National Pipe Straight Mechanical 95

99 Base Stands & Storage Cabinets Selection Guide Base stands and cabinets may be mixed or matched so that their total width equals the width of the Labconco fume hood or enclosure they support.* Base Stands Telescoping Hydraulic Lift Width x Depth w/fixed Feet w/casters Electric 115 Volts, 60 Hz Electric 230 volts, 50 Hz** Manual 24" x 25.5" " x 25.5" " x 29" " x 25.5" " x 29" " x 29" " x 29" Storage Cabinets Acid Solvent Width/Description Dual Doors Right Hinge Left Hinge Dual Doors Right Hinge Left Hinge 48" " " " " " w/self-closing doors " w/self-closing doors " w/self-closing doors " w/self-closing doors " ADA " ADA w/ self-closing doors " ADA Standard Vacuum Pump Width/Description Dual Doors Right Hinge Left Hinge Dual Doors Right Hinge Left Hinge 48" " " " " " " ADA " ADA " ADA * Basic Laboratory Hoods are not as wide or as deep as the base cabinets, stands and work surfaces that support them. ** International electrical configuration 96

100 Telescoping Base Stands Ordering Information Base Stands have telescoping legs so that they may be adjusted to seven height positions.* Features: Support Labconco fume hoods including Protector Premier, XStream, Stainless Steel, and PVC; Protector XL Benchtop and HOPEC IV; and Basic Hoods. Durable 1.75" tubular, epoxy-coated steel. Attractive glacier white exterior complements laboratory casework and Labconco fume hoods. Adjust to seven height positions in 1" increments from 27.5 to 33.5".* Include four fixed leveling feet or 5" diameter toe-locking casters. Work surface is sold separately. See pages Select the Base Stand that matches the width of the fume hood or enclosure it supports. When supporting Protector Hoods with widths of 8 feet or larger, Base Stands of multiple widths may be mixed and matched so that their total width equals the width of the hood. Telescoping Base Stands with Fixed Feet Telescoping Base Stand , 4" wide. Nominal Catalog # Width Depth Shipping For Use With: Width (A) (B) Wt. lbs./kg 2 feet " 25.5" 75/34 Protector VS Station 3 feet " 25.5" 95/43 Protector VS Station, Demonstration Hood 3 feet " 29.0" 100/45 Fiberglass 30 Hood** 4 feet " 25.5" 110/50 Protector VS Station 4 feet " 29.0" 110/50 Protector Hood, Basic 47 Hood,** Protector Work Station 5 feet " 29.0" 115/52 Protector Hood 6 feet " 29.0" 120/54 Protector Hood, Basic 70 Hood** Telescoping Base Stands with 5" diameter Toe-Locking Casters Nominal Catalog # Width Depth Shipping For Use With: Width (A) (B) Wt. lbs./kg 2 feet " 25.5" 80/36 Protector VS Station 3 feet " 25.5" 100/45 Protector VS Station, Demonstration Hood 3 feet " 29.0" 105/48 Fiberglass 30 Hood** 4 feet " 25.5" 115/52 Protector VS Station 4 feet " 29.0" 115/52 Protector Hood, Basic 47 Hood,** Protector Work Station 6 feet " 29.0" 125/57 Protector Hood, Basic 70 Hood** WITH With CASTERS casters A Front FRONT 27.5" min. 33.5" max. 3.2" 5.5" B 1.8" Side SIDE WITH With FIXED fixed FEET feet 8.2" A Front FRONT 27.5" min. 33.5" max. B 1.8" Side SIDE 8.2" * Height selection and adjustment are required before the hood or enclosure is installed atop the stand. ** Basic and Fiberglass 30 Hoods are narrower than the base stands that support them. Hoods and enclosures supported by mobile Base Stands will require special modifications to incorporate flexible ducting, wiring and plumbing when applied. 97

101 Electric & Manual Hydraulic Lift Base Stands Manual Hydraulic Lift Base Stand Optional accessory 5" diameter, toelocking Caster Kit is available for field installation. See below. Work surface is not included. See pages Features (Electric Hydraulic Lift Models): Include front-accessible up/down switch. Available in two electrical configurations. Models for 115 volt, 60 Hz operation include a 12-foot, 3-wire cord and plug. Models for 230 volt, 50 Hz operation include a 12-foot, 3-wire cord and NEMA 6-15P plug. Electrical components are UL listed. Manual Hydraulic Lift Base Stand has a hand crank accessible by wheelchair-bound individuals. Base stands have a built-in hydraulic lift so that height may be adjusted at any time. Stands are available with an electric lift and up/down switch or a manual lift and a hand crank. These adjustable stands allow you to position the stand and the hood or enclosure it supports to accommodate persons of different heights and wheelchair-bound users, to transport equipment through doorways, and easier service access. When coupled with a flat work surface, the stands may be used alone as an adjustable height table. Features (All Models): Support Protector Hoods, Basic and Fiberglass 30 Hoods. Support loads up to 1000 pounds. ADA-compliant. Durable 1.75" tubular, epoxy-coated steel frame with rear crossbar supports. Support frame is 2.0" x 3.0". Attractive glacier white exterior complements laboratory casework and Labconco products. Height is infinitely adjustable from 25.5" to 33.5" high. Include four powder-coated, die-cast feet with levelers. Features (Manual Hydraulic Lift Models): Include front-accessible hand crank. Turning the crank clockwise raises the stand; counterclockwise lowers it. The handle may be disengaged and folded under, out of the way, when not in use. Accessory Caster Kit* Casters add mobility to the Hydraulic Lift Base Stand. Kit includes four 5" diameter, non-marking polyurethane casters with toe locks. Load rating for each caster is 250 pounds. Casters have bearings for quiet operation. Casters replace the fixed feet that are included with the stand. Installation is required. Shipping weight 10 lbs. (4.5 kg) * Hoods and enclosures supported by mobile Base Stands will require special modifications to incorporate flexible ducting, wiring and plumbing when applied. 98

102 Electric & Manual Hydraulic Lift Base Stands Ordering Information Select the Base Stand that matches the width of the fume hood or enclosure it supports. Electric Hydraulic Lift Base Stands Nominal Catalog # Overall Switch Electrical Shipping For Width Width x Depth Location Requirements Wt. lbs./kg Use With: 3 feet " w x 34.3" d Right 115 volts, 100/45 Fiberglass 30 Hood Side 60 Hz, 2.4 amps 3 feet * 37.2" w x 34.3" d Right 230 volts, 100/45 Fiberglass 30 Hood Side 50 Hz, 0.8 amps 4 feet " w x 34.3" d Right 115 volts, 120/54 Protector Hood, Side 60 Hz, 2.4 amps Basic 47 Hood, Protector Work Station 4 feet * 49.2" w x 34.3" d Right 230 volts, 120/54 Protector Hood, Side 50 Hz, 0.8 amps Basic 47 Hood, Protector Work Station 6 feet " w x 34.3" d Right 115 volts, 150/68 Protector Hood Side 60 Hz, 2.4 amps Basic 70 Hood 6 feet * 73.2" w x 34.3" d Right 230 volts, 150/68 Protector Hood, Side 50 Hz, 0.8 amps Basic 70 Hood Manual Hydraulic Lift Base Stands Nominal Catalog # Overall Handle Shipping For Width Width x Depth Location Wt. lbs./kg Use With: 3 feet " w x 34.3" d Right 100/45 Fiberglass 30 Hood Side 4 feet " w x 34.3" d Right 120/54 Protector Hood, Basic 47 Hood, Side Protector Work Station 6 feet " w x 34.3" d Right 150/68 Protector Hood, Side Basic 70 Hood * International electrical configuration Up/Down Switch Electric Lift 9.5" A 29.0" 3-Foot Models A B , , " 37.2" 25.5" min. 33.5" max. 16.0" 4-Foot Models A B , , " 49.2" 6-Foot Models A B B 34.3" , , " 73.2" FRONT SIDE MANUAL LIFT Hand Crank A 7.4" 29.0" 4.4" Manual Lift 25.5" min. 33.5" max. B FRONT 34.3" SIDE 99

103 Protector Acid Storage Cabinets Protector Acid Storage Cabinet with dual doors, 36" wide. The interior of the Protector Acid Storage Cabinet is lined with polyethylene for corrosion resistance. Protector Acid Storage Cabinets support Labconco fume hoods and safely store and vent acids and other corrosive liquids. Dimensional Data Features: Support all Labconco benchtop fume hoods. Work surface is required. Durable epoxy-coated steel construction with corrosion-resistant polyethylene-lined interior. Attractive glacier white exterior complements laboratory casework and Labconco fume hoods. Manual-closing, non-locking door(s). Include vacuum-formed PVC liner tray. Include two rear vent connection cutouts for venting the cabinet into a fume hood. Vent Kit is sold separately. See page 101. Include four leveling feet and one 8" filler panel to increase cabinet depth from 22" to 30". Work surface and interior shelf kits are sold separately. See pages and " min " max " min. (ADA) 32.75" max. (ADA) 2.78" dia. Vent Connection Plumbing Access 5.44" 19.50" 15.50" (ADA) FRONT A 6.00" 12.00" REAR B 2.78" dia. Vent Connection 35.75" to achieve 37.00" Work Surface Height (ADA) 31.75" to achieve 33.00" Work Surface Height 3.75" min " 8.19" (ADA) 10.00" SIDE 22.06" Model A B 48" 48" 24" 36" 36" 18" 30" 30" 15" 24" 24" 12" 18" 18" 9" 24" ADA 24" 12" 18" ADA 18" 9" Filler Panel 8.00" Std " Opt " Opt " Opt. 100

104 Protector Acid Storage Cabinets Ordering Information Catalog # Cabinet Dimensions Depth with Door(s) Shipping (w x d x h) filler panel Wt. lbs./kg " x 22" x 35.5" to 36.75" 30" Dual 260/118 (122 x 56 x 90 to 93 cm) (76 cm) " x 22" x 35.5" to 36.75" 30" Dual 180/82 (91 x 56 x 90 to 93 cm) (76 cm) " x 22" x 35.5" to 36.75" 30" Dual 155/70 (76 x 56 x 90 to 93 cm) (76 cm) " x 22" x 35.5" to 36.75" 30" Single 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Right Hinge " x 22" x 35.5" to 36.75" 30" Single 90/41 (46 x 56 x 90 to 93 cm) (76 cm) Right Hinge " x 22" x 35.5" to 36.75" 30" Single 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Left Hinge " x 22" x 35.5" to 36.75" 30" Single 90/41 (46 x 56 x 90 to 93 cm) (76 cm) Left Hinge " x 22" x 31.5" to 32.75" 30" Single 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Right Hinge " x 22" x 31.5" to 32.75" 30" Single 85/39 (46 x 56 x 80 to 83 cm) (76 cm) Right Hinge " x 22" x 31.5" to 32.75" 30" Single 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Left Hinge " x 22" x 31.5" to 32.75" 30" Single 85/39 (46 x 56 x 80 to 83 cm) (76 cm) Left Hinge Accessories Vent Kit Includes one PVC adaptor, one 2" x 1" diameter reducer, two PVC 90 elbows, one 2" diameter PVC coupling, locknut, one 3' section of 2" diameter PVC pipe and one 1' section of 1" diameter PVC pipe for venting the cabinet through the SpillStopper Work Surface and into the fume hood. Shipping weight 5 lbs. (2.3 kg) Interior Shelf Kits Include epoxy-coated steel shelf, acid-resistant PVC tray and mounting hardware. Width Catalog # Shipping Wt. lbs./kg 48" /6.8 36" /5.4 30" /4.5 24" /3.6 18" /3.2 Filler Panels One 8" filler panel is included with each Storage Cabinet to extend cabinet depth to 30" and to enclose the utility chase behind the cabinet. Catalog # Description Shipping Wt. lbs./kg Filler Panel, 8" deep 10/ Filler Panel, 14" deep 13/ Filler Panel, 20" deep 15/ Filler Panel, 15.5" deep 13/ ADA Filler Panel, 8" deep 9/ ADA Filler Panel, 14" deep 12/ ADA Filler Panel, 20" deep 14/ ADA Filler Panel, 15.5" deep 12/5.4 Cabinet height meets requirements of the ADA. 101

105 Protector Solvent Storage Cabinets Protector Acid Storage Cabinet with dual doors, 36" wide. Protector Solvent Storage Cabinet , 30" wide, with dual, manual-closing doors. Protector Solvent Storage Cabinet , 30" wide, with dual, automatic self-closing doors. Protector Solvent Storage Cabinets support Labconco fume hoods and safely store and vent solvents and other flammable liquids. Features: Support all Labconco benchtop fume hoods. Work surface is required. Durable dual wall epoxy-coated steel construction with 1.5" air gap. Attractive glacier white exterior complements laboratory casework and Labconco fume hoods. Manual-closing or self-closing door(s) with 3-position locking handle. Selfclosing door(s) close automatically in case of fire when temperature reaches 165 F (74 C). All models meet OSHA* 29 CFR 1910, section specifications. Selfclosing Cabinets meet UFC 97. Include epoxy-coated steel interior shelf. Include two rear vent connections with flame arrestors and closure plugs. Include four leveling feet and one 8" filler panel to increase cabinet depth from 22" to 30". Work surface is sold separately. See pages " min " max " min. (ADA) 32.75" max. (ADA) FRONT A Plumbing Access 6.00" 6.64" 19.25" 15.25" (ADA) 2.78" dia. Flame Arrestor/ Closure Plug Dimensional Data 7.00" 12.00" REAR * Occupational Health and Safety Administration Uniform Fire Code B 7.00" 35.75" to achieve 37.00" Work Surface Height (ADA) 31.75" to achieve 33.00" Work Surface Height 3.75" min. 2.78" dia. Flame Arrestor/ Closure Plug 12.27" 10.27" (ADA) 8.00" Shelf Included SIDE 22.06" Model A B 48" 48" 24" 36" 36" 18" 30" 30" 15" 24" 24" 12" 24" ADA 24" 12" Filler Panel 8.00" Std " Opt " Opt " Opt. 102

106 Protector Solvent Storage Cabinets Ordering Information Catalog # Cabinet Dimensions Depth with Door(s) Shipping (w x d x h) standard filler panel Wt. lbs./kg * 48" x 22" x 35.5" to 36.75" 30" Dual 260/118 (122 x 56 x 90 to 93 cm) (76 cm) Manual * 36" x 22" x 35.5" to 36.75" 30" Dual 180/82 (91 x 56 x 90 to 93 cm) (76 cm) Manual * 30" x 22" x 35.5" to 36.75" 30" Dual 155/70 (76 x 56 x 90 to 93 cm) (76 cm) Manual " x 22" x 35.5" to 36.75" 30" Single, Right Hinge 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Manual " x 22" x 35.5" to 36.75" 30" Single, Left Hinge 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Manual " x 22" x 31.5" to 32.75" 30" Single, Right Hinge 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Manual " x 22" x 31.5" to 32.75" 30" Single, Left Hinge 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Manual " x 22" x 35.5" to 36.75" 30" Dual 260/118 (122 x 56 x 90 to 93 cm) (76 cm) Automatic " x 22" x 35.5" to 36.75" 30" Dual 180/82 (91 x 56 x 90 to 93 cm) (76 cm) Automatic " x 22" x 35.5" to 36.75" 30" Dual 155/70 (76 x 56 x 90 to 93 cm) (76 cm) Automatic " x 22" x 35.5" to 36.75" 30" Single, Right Hinge 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Automatic " x 22" x 35.5" to 36.75" 30" Single, Left Hinge 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Automatic " x 22" x 31.5" to 32.75" 30" Single, Right Hinge 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Automatic " x 22" x 31.5" to 32.75" 30" Single, Left Hinge 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Automatic Accessories Filler Panels One 8" filler panel is included with each Storage Cabinet to extend cabinet depth to 30" and to enclose the utility chase behind the cabinet. Catalog # Description Shipping Wt. lbs./kg Filler Panel, 8" deep 10/ Filler Panel, 14" deep 13/ Filler Panel, 20" deep 15/ Filler Panel, 15.5" deep 13/ ADA Filler Panel, 8" deep 9/ ADA Filler Panel, 14" deep 12/ ADA Filler Panel, 20" deep 14/ ADA Filler Panel, 15.5" deep 12/5.4 * Factory Mutual approved Meets National Fire Protection Association (NFPA) Flammable and Combustible Liquids Code specifications. Cabinet height meets requirements of the ADA. 103

107 Protector Standard Storage Cabinets Protector Standard Storage Cabinet , 24" wide, ADA height, with right hinge, single door. Protector Standard Storage Cabinet , 48" wide, with dual doors. Protector Standard Storage Cabinets support Labconco fume hoods and may be used for storage of supplies and small laboratory instruments. Features: Support all Labconco benchtop fume hoods. Work surface is required. Durable epoxy-coated steel construction. Attractive glacier white exterior complements laboratory casework and Labconco fume hoods. Dimensional Data 35.50" min " max " min. (ADA) 32.75" max. (ADA) FRONT A Plumbing Access 6.00" B 7.00" 35.75" to achieve 37.00" Work Surface Height (ADA) 31.75" to achieve 33.00" Work Surface Height 3.75" min. SIDE 22.06" Filler Panel 8.00" Std " Opt " Opt " Opt. Manual-closing, non-locking door(s). Include four leveling feet and one 8" filler panel to increase cabinet depth from 22" to 30". 6.64" 19.25" 15.25" (ADA) 2.78" dia " 2.78" dia " 10.27" (ADA) 8.00" Model A B 48" 48" 24" 36" 36" 18" 30" 30" 15" 24" 24" 12" Work surface and interior shelf kits are sold separately. See pages and " REAR 18" 18" 9" 12" 12" 24" ADA 24" 12" 18" ADA 18" 9" 12" ADA 12" 104

108 Protector Standard Storage Cabinets Ordering Information Catalog # Cabinet Dimensions Depth with Door(s) Shipping (w x d x h) standard filler panel Wt. lbs./kg " x 22" x 35.5" to 36.75" 30" Dual 260/118 (122 x 56 x 90 to 93 cm) (76 cm) " x 22" x 35.5" to 36.75" 30" Dual 180/82 (91 x 56 x 90 to 93 cm) (76 cm) " x 22" x 35.5" to 36.75" 30" Dual 155/70 (76 x 56 x 90 to 93 cm) (76 cm) " x 22" x 35.5" to 36.75" 30" Single 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Right Hinge " x 22" x 35.5" to 36.75" 30" Single 90/41 (46 x 56 x 90 to 93 cm) (76 cm) Right Hinge " x 22" x 35.5" to 36.75" 30" Single 65/29 (30 x 56 x 90 to 93 cm) (76 cm) Right Hinge " x 22" x 35.5" to 36.75" 30" Single 130/59 (61 x 56 x 90 to 93 cm) (76 cm) Left Hinge " x 22" x 35.5" to 36.75" 30" Single 90/41 (46 x 56 x 90 to 93 cm) (76 cm) Left Hinge " x 22" x 35.5" to 36.75" 30" Single 65/29 (30 x 56 x 90 to 93 cm) (76 cm) Left Hinge " x 22" x 31.5" to 32.75" 30" Single 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Right Hinge " x 22" x 31.5" to 32.75" 30" Single 85/39 (46 x 56 x 80 to 83 cm) (76 cm) Right Hinge " x 22" x 31.5" to 32.75" 30" Single 60/27 (30 x 56 x 80 to 83 cm) (76 cm) Right Hinge " x 22" x 31.5" to 32.75" 30" Single 120/54 (61 x 56 x 80 to 83 cm) (76 cm) Left Hinge " x 22" x 31.5" to 32.75" 30" Single 85/39 (46 x 56 x 80 to 83 cm) (76 cm) Left Hinge " x 22" x 31.5" to 32.75" 30" Single 60/27 (30 x 56 x 80 to 83 cm) (76 cm) Left Hinge Accessories Interior Shelf Kits Include epoxy-coated steel shelf and mounting hardware. Width Catalog # Shipping Wt. lbs./kg 48" /6.8 36" /5.4 30" /4.5 24" /3.6 18" /3.2 12" /2.3 Filler Panels One 8" filler panel is included with each Storage Cabinet to extend cabinet depth to 30" and to enclose the utility chase behind the cabinet. Catalog # Description Shipping Wt. lbs./kg Filler Panel, 8" deep 10/ Filler Panel, 14" deep 13/ Filler Panel, 20" deep 15/ Filler Panel, 15.5" deep 13/ ADA Filler Panel, 8" deep 9/ ADA Filler Panel, 14" deep 12/ ADA Filler Panel, 20" deep 14/ ADA Filler Panel, 15.5" deep 12/5.4 Cabinet height meets requirements of the ADA. 105

109 Protector Vacuum Pump Storage Cabinets Ordering Information Catalog # Cabinet Dimensions Depth with Door Shipping (w x d x h) standard filler panel Wt. lbs./kg " x 22" x 35.5" to 36.75" 30" Right 90/41 (46 x 56 x 90 to 93 cm) (76 cm) Hinge " x 22" x 35.5" to 36.75" 30" Left 90/41 (46 x 56 x 90 to 93 cm) (76 cm) Hinge Protector Vacuum Pump Storage Cabinet with left hinge door. Protector Vacuum Pump Storage Cabinets provide enclosed space for vacuum pump storage. Features: Durable epoxy-coated steel construction. Attractive glacier white exterior complements laboratory casework and Labconco fume hoods. Manual-closing, non-locking door. Include four leveling feet and one 8" filler panel to increase cabinet depth from 22" to 30". Include one 115 volt, 60 Hz electrical duplex receptacle to provide power to the vacuum pump. Wiring is required. Include two rear cutouts for pass through of vacuum pump tubing. Work surface is required and sold separately. See pages Accessories Filler Panels One 8" filler panel is included with each Storage Cabinet to extend cabinet depth to 30" and to enclose the utility chase behind the cabinet. Catalog # Description Shipping Wt. lbs./kg Filler Panel, 8" deep 10/ Filler Panel, 14" deep 13/ Filler Panel, 20" deep 15/ Filler Panel, 15.5" deep 13/5.9 Dimensional Data 35.50" min " max. 6.64" 19.25" 6.00" FRONT 18.00" 12.00" 9.00" 7.00" 35.75" to achieve 37.00" Work Surface Height 12.27" 8.00" 3.75" min. 1.00" 3.90" 8.40" 3.72" SIDE 22.06" Electrical Duplex Filler Panel 8.00" Std " Opt " Opt " Opt " max. Interior Depth 106 REAR 7.00" Plumbing Access 2.78" dia. Tubing Access (2 Holes) TOP 15.00" Interior Opening

Requires Ductwork and Blower

Requires Ductwork and Blower 6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and

More information

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory

More information

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy Hoods A Applications involving perchloric acid, acid

More information

Protector XStream Laboratory Hoods

Protector XStream Laboratory Hoods High Performance Hood offers enhanced containment combined with energy savings. With its unsurpassed containment and substantial energy savings potential, the patented* Protector XStream Fume Hood delivers

More information

Laboratory Fume Hoods & Enclosures

Laboratory Fume Hoods & Enclosures Laboratory Fume Hoods & Enclosures Protector ClassMate Laboratory Hoods Fiberglass 30 Laboratory Hoods Protector Demonstration Hoods Basic Laboratory Hoods Protector XVS Ventilation Stations Canopy Hoods

More information

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits Protector XL FLOOR-MOUNTED LAORATORY HOODS Protector XL Floor-Mounted Laboratory Hoods Features & enefits Protector XL Floor-Mounted Laboratory Hoods accommodate laboratory procedures that require over-sized

More information

Completing Your Fume Removal System

Completing Your Fume Removal System Once a laboratory hood has been selected, the next step is to select the proper blower and ductwork. It is important that these be sized correctly depending on hood size, application, CFM, and distance

More information

Accessories Standard Service Fixture Kits

Accessories Standard Service Fixture Kits Standard Service Fixture Kits For mounting on the left or right side of any Protector Premier, XStream, XL, XLE or PVC Hood. Each kit includes one remotely-controlled service fixture with valve and 0.25"

More information

Protector Demonstration Hoods

Protector Demonstration Hoods Protector Demonstration Hoods Protector Demonstration Hoods are low profile, light-duty fume hoods designed to provide close observation of procedures during educational demonstrations. ll models feature:

More information

Laboratory Fume Hoods & Enclosures

Laboratory Fume Hoods & Enclosures Laboratory Fume Hoods & Enclosures Protector ClassMate Laboratory Hoods Fiberglass 30 Laboratory Hoods Protector Demonstration Hoods Basic Laboratory Hoods Protector XVS Ventilation Stations Canopy Hoods

More information

LABORATORY FUME HOODS

LABORATORY FUME HOODS Fume Hoods Fume Hood Applications Laboratory professionals and students across the country, and all over the world, depend on the safety of our hoods. Your protection is our first concern and the fume

More information

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories Protector Storage Cabinets, Base Stands & Fume Hood Accessories Storage Cabinets & Base Stands Selection Guide Complete your installation of a Labconco fume hood or enclosure with a Labconco base cabinet

More information

LABORATORY FUME HOODS OF 5

LABORATORY FUME HOODS OF 5 SECTION 11 5313 - LABORATORY FUME HOODS AND RELATED PRODUCTS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Bench-top laboratory fume hoods. 2. Service fittings and electrical service fitting inside

More information

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features Fume hood construction details 1 9 2 10 3 11 13 4 14 5 15 6 16 17 7 12 18 8 Features 1 Fluescent light fixture with interi sealed glass offering a safe and bright wking area (100 foot candles) 2 SEFA-8

More information

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features Fume hood construction details 1 2 3 4 5 6 7 9 10 11 13 14 15 16 17 12 18 8 Features 1 Fluescent light fixture with interi sealed glass offering a safe and bright wking area (100 foot candles) 2 SEFA-8

More information

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS Optional 254 nm UV lamp Contain-Air Negative Pressure Channel Bright, glare-free fluorescent lighting Fully-closing, counterbalanced tempered

More information

Laboratory Fume Hood. Operation & Maintenance Manual APR 2005

Laboratory Fume Hood. Operation & Maintenance Manual APR 2005 Laboratory Fume Hood Operation & Maintenance Manual APR 2005 TABLE OF CONTENTS I. Introduction p. 3 II. Fume Hood Services p. 4 III. Operation Recommendations p. 4 IV. General Fume Hood Maintenance p.

More information

Protector Echo Filtered Fume Hoods

Protector Echo Filtered Fume Hoods Protector Echo Filtered Fume Hoods Labconco has combined its patented* fullyfeatured, containment-enhancing Protector Hood design with Erlab s GreenFumeHood (GFH) Filtration Technology to deliver a multi-use

More information

new fume hoods providing performance and protection

new fume hoods providing performance and protection new fume hoods providing performance and protection five questions to get us started 1. Will the use of your hood require a special application hood? 2. How high of a priority is energy conservation? 3.

More information

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories Protector Storage Cabinets, Base Stands & Fume Hood Accessories Storage Cabinets & Base Stands Selection Guide Complete your installation of a Labconco fume hood or enclosure with a Labconco base cabinet

More information

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service

More information

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service

More information

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures Made in the USA. Select the Right Laboratory Ventilation Product Fume hoods, biological safety cabinets and ventilation enclosures protect

More information

F. VAV hoods shall have a restricted bypass plate.

F. VAV hoods shall have a restricted bypass plate. 1.01 SUMMARY A. Section Includes: 1. Laboratory fume hoods. B. Related Sections: 1. Section 6500 Laboratory casework 2. Section 15 Mechanical: Furnishing and installation of plumbing utilities and final

More information

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME Supreme AirLV- LOW CONSTANT VOLUME FUME HOODS KEWAUNEE encouraging new discovery Supreme Air LV Fume Hood Low Velocity Low Volume Full Access Hold-Open Catch for set-up sash position Flush Mounted Convergent

More information

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS 1.01 SUMMARY A. Section Includes: Fume hoods LABORATORY FUME HOODS B. Related Sections 1. Division 12 Section - 12345 - Steel Laboratory Casework 2. Division 12 Section - 12346 - Agility Adaptable Furniture

More information

Fume Hoods Overview OVERVIEW

Fume Hoods Overview OVERVIEW OVERVIEW What Is A Fume Hood - A laboratory chemical fume hood is first and foremost a safety device. Users need to be able to rely on their fume hood as a primary containment device to protect them from

More information

LABORATORY FUME HOODS

LABORATORY FUME HOODS Fume Hoods Fume Hood Applications Laboratory professionals and students across the country, and all over the world, depend on the safety of our hoods. Your protection is our first concern and the fume

More information

Protector Airo Filtered Fume Hoods

Protector Airo Filtered Fume Hoods PROTECTOR OR AIRO FILTERED FUME HOODS Protector Airo Filtered Fume Hoods If you have robust chemical applications requiring a fume hood but have low ceiling height and no means to duct to the outside,

More information

FUME HOOD SELECTION GUIDE

FUME HOOD SELECTION GUIDE FUME HOOD SELECTION GUIDE FUME HOOD SELECTION GUIDE Laboratory fume hoods are one of the most vital pieces of safety equipment in a working laboratory. Fume hoods are designed to safely exhaust dangerous

More information

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017 DEPAUL UNIVERSITY Fume Hoods Manual Environmental Health & Safety April 2017 1 TABLE OF CONTENTS SECTION PAGE NO. 1. INTRODUCTION 2 2. TYPES OF FUME HOODS 2 2.1 CONVENTIONAL FUME HOODS 2 2.2 HIGH PERFORMANCE

More information

January, 2014 Page 1 of 6

January, 2014 Page 1 of 6 Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying chemical fume hood modifications or installations. These standards are not intended to restrict or replace

More information

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES SECTION 11610.1 LABORATORY LE FUME HOODS UNIFLOW LE SERIES REVISED AUGUST 2, 2013 LABORATORY FUME HOODS UNIFLOW LE SERIES PART 1 GENERAL 1.00 SUMMARY A. Section Includes: 1. Laboratory Fume Hoods B. Related

More information

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery Supreme Air LABORATORY Fume Hoods KEWAUNEE encouraging new discovery Stainless Steel H05 Fume Hood with Vertical Rising Sash LV05 Low Constant Volume Fume Hood Supreme Air Fume Hoods Kewaunee s Fume Hood

More information

3.5 Exposure Control Measures

3.5 Exposure Control Measures 3.5 Exposure Control Measures 3.5.1 Chemical Fume Hoods Chemical fume hoods are the most reliable and primary engineering control used in the laboratory to protect against the inhalation of hazardous vapors

More information

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist Fume Hood Program Program originated: 08/2008 Updated: 06/2016 Gordon Krueger Environmental Safety Specialist 1 TABLE OF CONTENTS I. INTRODUCTION 3 II. LABORATORY VENTILATION 3 A. Chemical Fume Hood Types

More information

82863_Graphx_Conn:Layout 1 11/26/08 8:59 AM Page 1 DUCTLESS ENCLOSURES

82863_Graphx_Conn:Layout 1 11/26/08 8:59 AM Page 1 DUCTLESS ENCLOSURES DUCTLESS ENCLOSURES TABLE of CONTENTS Overview...................................3 Features & Benefits...........................6 Specifications................................7 Ordering Information.........................8

More information

Protector Controlled Atmosphere Glove Boxes

Protector Controlled Atmosphere Glove Boxes Protector Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Protector Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contaminationsensitive materials. Organometallic

More information

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION RDM Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION Table of Contents Airfoil ADA Fume Hoods...12 Demonstration Fume Hood...22 ADA Fume Hood Assemblies...13 Drains... 30 SB-MAX-A

More information

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall: Fume Hood Standard A fume hood is an enclosed working chamber fitted with an exhaust ventilation system. It is one component of an exposure control system which is designed to contain, dilute and disperse

More information

Appendix C: Biosafety Cabinet Specifications C-1. Product Service

Appendix C: Biosafety Cabinet Specifications C-1. Product Service Appendix C: Biosafety Cabinet Specifications C-1 Product Service 1-800-522-7658 111 Appendix C: Biosafety Cabinet Specifications C-2 112 Product Service 1-800-522-7658 Appendix C: Biosafety Cabinet Specifications

More information

Laboratory Carts & Benches

Laboratory Carts & Benches Laboratory Carts & Benches Labconco Laboratory Carts and Benches fit in every lab. These versatile carts have endless uses from transporting equipment and supplies to providing auxiliary bench space. Labconco

More information

Appendix C: Biosafety Cabinet Specifications C-2. Product Service

Appendix C: Biosafety Cabinet Specifications C-2. Product Service Appendix C: Biosafety Cabinet Specifications C-2 102 Appendix C: Biosafety Cabinet Specifications C-3 103 Appendix C: Biosafety Cabinet Specifications C-4 104 Appendix C: Biosafety Cabinet Specifications

More information

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section ) Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying Laboratory Fume Hoods. These standards are not intended to restrict or replace professional judgment..2

More information

PRECISE. Glove Boxes

PRECISE. Glove Boxes PRECISE Glove Boxes PRECISE Basic Glove Boxes All models feature: One-piece molded, medium-density polyethylene shell. Dry powder epoxy-coated steel superstructure. 1/4" thick laminated safety glass viewing

More information

Design Standard - Fume Hoods & Fume Hood Exhausts

Design Standard - Fume Hoods & Fume Hood Exhausts Design Standard - Fume Hoods & Fume Hood Exhausts 1.0 Introduction The fume hood is the primary control device in most laboratories for protecting employees and students from exposure to hazardous chemicals.

More information

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com Laboratory Demonstration Space Located at Price Research Center North Winnipeg Fume Hoods ehpricesales.com 2 www.ehpricesales.com FUME HOODS Contents Dynamic Bench Fume Hood Features High Performance Fume

More information

CORPORATION DURALAB CORPORA

CORPORATION DURALAB CORPORA DURALAB CORPORATION The Tradition Continues the most complete, versatile and colorful line of LABORATORY FUME HOODS and accessories DURALAB CORPORATION 3145 Bordentown Avenue Parlin, NJ 08859 Ph: 888-805-1740

More information

How to Use a Chemical Fume Hood Safely

How to Use a Chemical Fume Hood Safely Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) How to Use a Chemical Fume Hood Safely SafetyNet #: 35 A chemical fume hood is designed to protect the worker from volatile and

More information

Bedcolab Vanguard Laboratory Fume Hoods

Bedcolab Vanguard Laboratory Fume Hoods Bedcolab Vanguard Laboratory Fume Hoods 1. General 2. Conditions 3. Scope of work A. This section includes all material, equipment, tools and workmanship related to the supply and installation of fume

More information

PROTECTOR FIBERGLASS ENCLOSURES

PROTECTOR FIBERGLASS ENCLOSURES PROTECTOR FIBERGLASS ENCLOSURES for PCR and Tissue Culture Protector Fiberglass PCR Enclosures Protector Fiberglass Tissue Culture Enclosures Protector Fiberglass PCR & Tissue Culture Enclosures Protector

More information

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R BMC Laboratory Fume Hoods M E M B E R SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION Table of Contents Airfoil ADA Fume Hoods...12 ADA Fume Hood Assemblies...13 Add Air Fume Hoods...10 Add Air Fume

More information

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery DetectAir FILTERED FUME HOODS KEWAUNEE encouraging new discovery KEWAUNEE DetectAir Filtered Fume Hoods powered by 2 Kewaunee encouraging new discovery DetectAir Filtered Fume Hoods powered by AirClean

More information

Labconco 48, 60, and 72 Hoods

Labconco 48, 60, and 72 Hoods Labconco 48, 60, and 72 Hoods PROTECTOR LABORATORY HOODS INSTRUCTION MANUAL Model Nos. Remote Blower Integral Blower Style Style 48705 60705 72705 48713 60713 72713 48707 60707 72707 48714 60714 72714

More information

LABORATORY HOOD MANUAL

LABORATORY HOOD MANUAL LABORATORY HOOD MANUAL DRAKE UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY November 2015 TABLE OF CONTENTS I. INTRODUCTION... 1 II. FUME HOOD SERVICE... 2 Fume Hood Service Provided by EH&S... 2 Fume Hood Service

More information

Ducting & Ventilation Components

Ducting & Ventilation Components Ducting & Ventilation Components 111 Powell Road Independence, MO 64056 visit www.hemcocorp.com Phone: 816-796-2900 Fax : 816-796-3333 E-Mail : info@hemcocorp.com Exhaust Blowers are constructed of chemical

More information

Precise Glove Boxes & XPert Weigh Boxes

Precise Glove Boxes & XPert Weigh Boxes Precise Glove Boxes Precise Glove Boxes & XPert Weigh Boxes O V E R V I E W Table of Contents Overview................................................ 3 Selection Guide.........................................

More information

LABGARD FEATURES

LABGARD FEATURES LABGARD 425 - FEATURES Front Filter Removal and Maintenence Minihelic Guage Sliding Tempered Glass Window Closes Completely Duplex Outlet 10 Access Opening Ergonomic PVC Armrest Optional Base Stand Clean

More information

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust 2 BERNER INTERNATIONAL Claire total At a glance CLAIRE TOTAL PRO CHEMISTRY Protection Shield The multiple award-winning Shield

More information

Air Sentry High Performance Fume Hood Operation & Maintenance Manual

Air Sentry High Performance Fume Hood Operation & Maintenance Manual Air Sentry High Performance Fume Hood Operation & Maintenance Manual Revision 8 TABLE OF CONTENTS I. Introduction p. 3 II. High Performance Fume Hoods p. 4 III. Vortex Control System p. 5 IV. Uncrating

More information

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series User s Manual Protector ClassMate Laboratory Fume Hoods Models 69704 Series 69705 Series 69706 Series 69714 Series 69715 Series 69716 Series To receive important product updates, complete your product

More information

Model ND-2 Specification

Model ND-2 Specification Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction

More information

Thermo Scientific Hamilton Air Flow Products. Table of Contents

Thermo Scientific Hamilton Air Flow Products. Table of Contents Table of Contents Fume Hood Technology and Terms...4-11 Operating Instructions...12 Ordering Information...14-15 Fume Hood and Exhaust Unit Selections...16-87 SafeAire Fume Hood...16-47 Concept Fume Hood...49-60

More information

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry Series Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry Esco Ascent Opti Ductless Fume Hood Provides Operator and Environment Protection Sampling Port Easy Filter Change Esco

More information

Fume Hood Operation & Maintenance Manual

Fume Hood Operation & Maintenance Manual Fume Hood Operation & Maintenance Manual Fume Hood Operation & Maintenance Manual TABLE OF CONTENTS Fume Hood Applications 2 Safety 3 Aerodynamic Principles & Safety 4 Fume Hood Cleaning 7 Basic Maintenance

More information

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

A. Each cabinet must be constructed and installed in accordance with EN12469:2000. BIOLOGICAL SAFETY CABINETS Class II, Biological Safety Cabinet PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this section to the extent referenced. The publications are referred

More information

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G User s Manual LabShield By CampbellRhea Laboratory Fume Hoods Air Foil By-Pass Models: 6714, 6716, 6718 ADA Models: 8796, 8798, 8800 Demonstration Hood 6725G CampbellRhea 1865 North Market Street Paris

More information

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE SECTION 11 53 00 (11610) - LABORATORY FUME HOODS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

More information

Polypropylene Total Exhaust Fume Hoods

Polypropylene Total Exhaust Fume Hoods Polypropylene Total Exhaust Fume Hoods 24 36 48 Provides Comprehensive Operator Protection and Optimum Performance 60 72 96 PTEFH-48 shown on optional vented base cabinet Provides Personnel Protection

More information

Lab Safety & Energy Optimization. Introduction & Agenda

Lab Safety & Energy Optimization. Introduction & Agenda Lab Safety & Energy Optimization Determining Appropriate Airflow Specifications for VAV Fume Hoods Thomas C. Smith tcsmith@labhoodpro.com Introduction & Agenda Thomas C. Smith President, BSME (NCSU), MSEE

More information

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting ULTRASUITE Operating Room Diffuser System with Integrated LED Lighting ULTRASUITE Ultrasuite is a customizable air distribution and lighting solution specifically engineered for hospital operating rooms.

More information

SAMPLE. Engine Driven Welding Power Sources. Topic 5. Welding Process Training Series

SAMPLE. Engine Driven Welding Power Sources. Topic 5. Welding Process Training Series Topic 5. Welding Process Training Series Engine Driven Welding Power Sources Prepared by the Miller Electric Mfg. Co. Training Department. 2014 Miller Electric Mfg. Co. The contents of this publication

More information

Compounding Safety Solutions.

Compounding Safety Solutions. Compounding Safety Solutions HRT, Pain, & Vet Compounding PowderSafe Type A Enclosure AirClean Systems PowderSafe Type A enclosures are designed to provide operator protection from hazardous compounds

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench Series 301 Horizontal Laminar Flow Clean Bench s o l u t i o n s The Series 301 is a general-purpose, horizontal flow clean bench ideally suited to many types of mechanical or processing work. It is designed

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3042 on exhaust and ventilation with specific criteria for projects involving design of Laboratory Exhaust and Systems.

More information

AUDIO-VISUAL EQUIPMENT

AUDIO-VISUAL EQUIPMENT 11 52 00 AUDIO-VISUAL EQUIPMENT 1. GENERAL A. Related sections: i. 00 00 13 Designing Learning Environments ii. 11 52 13 Projection Screens iii. 12 56 52 Audio-Visual Equipment iv. 72 41 00 General Audio-Visual

More information

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet Airstream Class II, Biosafety Cabinet, Model AC2-4E_. RS 232 Serial Interface Port Send operational

More information

Fume Hoods. Selection Guide. Fume Hoods. Accessories & Options. Clean Benches. Ductless Fume Hoods. Description Filter Work Surface Page.

Fume Hoods. Selection Guide. Fume Hoods. Accessories & Options. Clean Benches. Ductless Fume Hoods. Description Filter Work Surface Page. Clean Benches. Ductless. Selection Guide Description Filter Work Surface Page BC-01E Clean Benches Ductless BC-11E BC-21E DLH-01G Optional 6 Different DLH-11G Filters HEAP Filter Stainless Steel #304 26

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

Ventilated Balance Enclosures

Ventilated Balance Enclosures Ventilated Balance Enclosures by PLAS n LABS Meets and exceeds ANSI/ASHRAE 110:2016 standard for containment & performance PLAS n LABS, INC. www.plas-labs.com PLI@PLAS-LABS.com 517-372-7177 Ventilated

More information

Fume extractor is warranted for two years, parts and labor.

Fume extractor is warranted for two years, parts and labor. Industrial Centralized Systems Issued Feb. 7 Index No. AY/. Welding Safety and Health Quick Specs Industrial Applications Manufacturing and fabrication Schools and training centers Processes Stick (SMAW)

More information

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria 1) The laboratory fume hoods must confirm to the following regulations and standards. 2) ASHRAE 110 1995, American

More information

Protector XStream Laboratory Fume Hoods

Protector XStream Laboratory Fume Hoods User s Manual Protector XStream Laboratory Fume Hoods Models 9840400, 9840401, 9840402, 9840403, 9840500, 9840501, 9840502, 9840503, 9840600, 9840601, 9840602, 9840603, 9840800, 9840801, 9840802, 9840803

More information

PCR Laminar Flow Cabinets

PCR Laminar Flow Cabinets PCR Laminar Flow Cabinets The World s Most Practical Selection of Benchtop PCR Cabinets. 24 36 48 Purair PCR-24 Provides Contaminant-Free Interior for PCR Applications and Protects Against Cross-Contamination

More information

TABLE OF CONTENTS STANDARDS FOR THE DESIGN, CONSTRUCTION, MAINTENANCE AND USE OF LABORATORY FUME HOODS. Effective August 2010

TABLE OF CONTENTS STANDARDS FOR THE DESIGN, CONSTRUCTION, MAINTENANCE AND USE OF LABORATORY FUME HOODS. Effective August 2010 TABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 BACKGROUND... 2 FUME HOOD DESIGN AND CONSTRUCTION... 3 VARIABLE AIR VOLUME FUME HOODS... 3 RECIRCULATING HOODS... 3 SPECIAL LABORATORY FUME HOODS...

More information

User s Manual. Fiberglass 30 Laboratory Fume Hoods. Models Labconco s Mascot, Labby the LABster

User s Manual. Fiberglass 30 Laboratory Fume Hoods. Models Labconco s Mascot, Labby the LABster User s Manual Fiberglass 30 Laboratory Fume Hoods Models 3030000 3030001 3030002 3030003 3030004 3030005 Labconco s Mascot, Labby the LABster The information contained in this manual and the accompanying

More information

Smart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific

Smart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific Smart design has its rewards NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet Part of Thermo Fisher Scientific MSC MSC-Advantage: Laboratories today are facing new challenges. Safety

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

STATE UNIVERSITY CONSTRUCTION FUND

STATE UNIVERSITY CONSTRUCTION FUND DIRECTIVE 15H-8 Issue date: June 2016 1. General Design Criteria LABORATORY DESIGN a. Design a Pressure Independent Variable Volume system that satisfies the airflow demand of the fume hoods, minimum air

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

HEMCO. Laboratory Fume HoodsR

HEMCO. Laboratory Fume HoodsR Laboratory Fume HoodsR UniFlow SE Hoods UniFlow LE Hoods 2018 Made in USA 9001: 2008 Certified 60th Year UniFlow AireStream Laboratory Fume Hoods Fume Hood Service Components Special Purpose Hoods Laboratory

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS JANUARY 2012 SECTION FUME HOODS AND LOCAL EXHAUST SYSTEMS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS JANUARY 2012 SECTION FUME HOODS AND LOCAL EXHAUST SYSTEMS SECTION 15860 - FUME HOODS AND LOCAL EXHAUST SYSTEMS This standard describes fundamental good practices relating to the design, selection, installation, commissioning, and testing of local exhaust systems

More information

AUDIO-VISUAL EQUIPMENT

AUDIO-VISUAL EQUIPMENT 11 52 00 AUDIO-VISUAL EQUIPMENT 1. GENERAL A. Related sections: i. 00 00 13 Designing Learning Environments ii. 11 52 13 Projection Screens iii. 12 56 52 Audio-Visual Equipment iv. 72 41 00 General Audio-Visual

More information

LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC.

LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC. LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC. LFBC THE FLOW SCIENCES GLOVEBOX WORKSTATION SERIES safety. The Glovebox Workstation series provides provides containment containment

More information

SDL Single-Duct, Low-Height, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely

More information

Frontier. Laboratory Fume Hood. Perfectly tailored solutions for your fume containment needs

Frontier. Laboratory Fume Hood. Perfectly tailored solutions for your fume containment needs Frontier Laboratory Perfectly tailored solutions for your fume containment needs 2 About Esco...02 Esco Frontier s are Tested and Certified for Safety.03 Esco Global Network and Product Overview...04 General

More information

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Item Number-1 ----------------------------------------------------------------------------------------------------------

More information