InstrumentationTools.com
|
|
- Lenard Lester
- 5 years ago
- Views:
Transcription
1 Author: Instrumentation Tools Categories: Instrumentation Design Thermowell Design Guidelines When fluid flows past a thermowell inserted into a pipe or duct, vorticies form at both sides of the well. These vorticies detach, first from one side, and then from the other. This phenomenon is known as the Von Karmann effect. The frequency of shedding of these vortices is a function of the diameter of the thermowell, the fluid velocity and, to a lesser extent, the Reynolds number.the vortex shedding subjects the thermowell to a periodic transverse force. As the vortex shedding frequency approaches the natural frequency of the thermowell, the thermowell will
2 oscillate, and is liable to snap off. (The natural frequency of the thermowell is a function of its shape and material of manufacture.) The Von Karmann effect must be taken into account when designing thermowells of sufficient strength to withstand service conditions, and generally thermowells are chosen such that the shedding frequency is always less than or equal to 80% of the natural frequency. Thermowell points to be taken care- Thermowell dimension and well material shall be specified on data sheet and surface finish shall be manufacturer s standard. Tolerances are as follows: 1. Bore, d shall be 0.26 inch maximum to pass plug gauge of inch OD.
3 2. Bore /OD eccentricity shall be +/- 10 percent of minimum wall thickness. 3. Bore depth shall be +/- 1/32 inch for depths to 30 inches. 4. Overall length, L shall be +/- 1/32 inch for lengths to 30 inches. 5. Insertion Length, U shall be +/- 1/16 inch for lengths to 12 inches and +/- 1/8 inch for lengths over 12 inches. 6. Head diameter shall be +/ inch 7. Shank diameter shall be +/ inch 8. Tip diameter shall be +/- 1/32 inch 9. Tip thickness +/- 1/32 inch 10. Thermowells shall have the tag number and material on the well head. For test thermowells, provide 1/2-inch NPT brass plug with brass chain attached to head of well by non-welding technique. Bore drilling may be performed either by twist drill or gun drill. Thermowells purchased for installation on piping and vessels are categorized into four types: 1. Machine Thread ( MT Type) recommended for wall thicknesses more than 3/4 inch; 2. 1-inch NPT Threaded ( T Type) used for line sizes 6 inches and smaller, with wall thicknesses less than or equal to 3/4-inch; /4 inch NPT Threaded ( T Type) used for line sizes 8 inches and larger, with wall thicknesses less than or equal to 3/4-inch; and 4. 3-inch 150# Flanged ( F Type) used for lined piping, atmospheric tanks and vessels.
4
5
6
7
8 Van Stone Thermowells It is advisable to use full penetration welds for flanged thermowells to achieve the highest fatigue strength rating. Forged thermowells accomplish the same goal without welds, but at a much higher cost. Van Stone style thermowells accomplish this without the cost. Van Stone termowells are machined from solid bar and are connected using a separate and reusable backing flange. Van Stone termowells mounted between mating flanges for process insertion.
9 Powered by TCPDF ( Instrumentation Tools This design offers two advantages: 1. Any weld stress is eliminated. 2. The slip on flange not being exposed to the process conditions can be of a less expensive material. Applications: Chemical, process, apparatus and plantengineering; petrochemical; on/offshore High chemical loads High process loads Also Read: Thermowell Insertion & ImmersionLength
Article on Sheath materials, Thermowells, Fittings, and Terminations
Article on Sheath materials, Thermowells, Fittings, and Terminations 1. INTRODUCTION Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or
More informationRosemount Twisted Square Thermowells
Product Data Sheet November 2017 00813-0300-4952, Rev AA Rosemount Twisted Square Thermowells Wide variety of industry standard process connections including flanged, threaded, welded, and Van Stone Large
More informationTemperature Controls Pty Ltd ACN: ABN:
Temperature Controls Pty Ltd ACN: 075 298 592 ABN: 966 501 901 83 Sydney (Head Office): 7 Yamma St, Sefton, NSW 2162 Australia Ph: 61 2 9721 8644 Fax: 61 2 9738 9339 Melbourne: 8/280 Whitehall St, Yarraville
More informationBimetal Thermowells Threaded
Bimetal Threaded Stepped Shank P P EXTERNAL THREAD [7] 2 1 / 2 only.75.75 [19] Lagging fl.50 Ø.50 [13] 1/2 P EXTERNAL THREAD P EXTERNAL THREAD [7] P P EXTERNAL THREAD THREAD.260 Ø.260 [7] [7].40.40 [10]
More informationThermowells Explained Application Notes
Thermowells are hidden in pipes and are rarely seen. How dimensions are established for the wells and the immersion probes that fit into them are not readily apparent. This application note exposes how
More informationAccuTru Thermowells. Dedicated to those organizations that value improved temperature measurement for critical processes
S E N S O R T E C H N O L O G I E S AccuTru Thermowells Dedicated to those organizations that value improved temperature measurement for critical processes Section 5 Index Thermowells Model Page PT-1
More informationFAX: SPECIAL APPLICATION HOSES, METAL & TEFLON HOSES
Large Bore Teflon Fittings Selection Pipe Thread (NPT) Style 03 Flanges Lap Joint Flange Style 12 Shown with epoxy coated steel flange Cam and Groove Female Swivel Type Style 16 Also available Teflon Encapsulated
More informationThermowell for temperature sensors omnigrad M TW 13
Technical information TI 264T/02/en 60019743 Thermowell for temperature sensors omnigrad M TW 13 Pipe thermowell Flanged process connection Omnigrad M TW 13 thermowells are designed for the use in the
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationBore (B) Pitch Diam. Drilling Template Flanges (1) Diam of Diam of. Groove. Neck D X G A Raised Face Raised Face P Raised face
Class 300 Orifice s Pipe size Thickness of Depth of jack Jack screw s (1) screw slot size & of and raised face Hub Bevel threaded Length of of Stud stud bolts Face face face bolt circle Bolts Bolts Bolt
More informationFUNCTION OF A BEARING
Bearing FUNCTION OF A BEARING The main function of a rotating shaft is to transmit power from one end of the line to the other. It needs a good support to ensure stability and frictionless rotation. The
More informationModel 1000 Vortex Meter
Model 1000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...
More information-- Installation Instructions --
1 DOWNLOAD ENHANCED INSTALL MANUALS AT dieselperformance.com BD PERFORMANCE DODGE T4 5.9L CUMMINS EXHAUST MANIFOLD -- Installation Instructions -- Application List 1045987-T4 2003-2007 Dodge 24V -- PLEASE
More informationSWING CHECK VALVES SERIES 52-SC SERIES 600
SWING CHECK VALVES SERIES 52-SC SERIES 600 FEATURES/BENEFITS/SPECIFICATIONS AMERICAN Flow Control Series 52-SC Swing Check Valves incorporate design features to help increase service life for water and
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More informationPerformance requires quality.
131 - With straight shank and square - Left-hand spiral 7-8 - First cut 1/4 of the cutting length (l 2 ) - Accuracy Hand Reamers DIN 26. Not suitable for blind holes. d 1 l 2 l 1 d 2 131 2, 25 5 1,6 21
More informationIndustrial Pt100 RTD's
CA 2001 Resistance Welded process connection measuring insert. Can be Type CA 2001 CA 2003 Resistance Welded process connection 1/2"BSP Head extension 50mm standard. Aluminium Replaceable 6mm Din insert.
More informationLong Welding Neck Flanges Catalogue
Hydraulic & Offshore Supplies Long Welding Neck Flanges Catalogue YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE LONG WELDING NECK FLANGES
More informationThermowell for temperature sensors omnigrad M TW 11
Technical information TI 262T/02/en 71106961 Thermowell for temperature sensors omnigrad M TW 11 Pipe thermowell without extension neck Threaded process connection Omnigrad M TW 11 thermowells are designed
More informationORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES
ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES INTERNATIONAL METAL ENGINEERING International Metal Engineering Orifice Plates A t Model 785 Orifice Plate is a differential pressure
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationInstructions for 4616 KYB shock rebuild and valve installation:
The goals of any suspension builder should be the same. That is to precisely build suspension in a repeatable, and efficient manner. All components must be modified so as to not threaten long-term component
More informationSecoroc Rock Drilling Tools Tapered equipment
Secoroc Rock Drilling Tools Tapered equipment The lowest cost per metre drilled is now lower than ever The lowest cost per metre drilled has long been synonymous with Secoroc products. Our Uppercut tapered
More information1 Aeroelasticity Phenomenon (Tacoma Narrows Bridge Disaster) Figure 1 Tacoma Narrows Bridge Disaster
1 Aeroelasticity Phenomenon (Tacoma Narrows Bridge Disaster) Background This project deals with the interaction of wind with the elastic characteristics of a structure, which enables the structure to take
More informationAUXILIARY COMPONENTS
CHAPTER 9 AUXILIARY COMPONENTS Fluid Power Circuits and Controls, John S.Cundiff, 2001 INTRODUCTION Discussion of the hardware needed to connect the various components (pumps, actuators, valves, accumulators,
More informationRosemount 68 Sensor and Thermowell
Rosemount 68 Sensor and Thermowell The Rosemount 78 Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments. Features include: Industry-standard
More informationSolar Boat Capstone Group
Solar Boat Capstone Group Design Team Chris Maccia, Jeff Tyler, Matt Knight, Carla Pettit, Dan Sheridan Design Advisor Prof. M. Taslim Abstract Every year Solar Splash, the IEEE World Championship of intercollegiate
More informationKOBOLD DF-MA Flow Transmitter. User Instructions
KOBOLD DF-MA Flow Transmitter User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-DF-MA_12-13 DF-MA Table
More informationModel 8800C Vortex Flowmeter
Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Review Flowmeter Configuration Product Certifications
More informationModel 3201 Liquid Level Controller
Model 3201 Liquid Level Controller The Model 3201 Liquid Level Controller is ideal for oilfield scrubber and separator applications. Its rugged and versatile design make it the preferred choice of production
More informationVorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual
Series M22/M23 Instruction Manual Table of Contents VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters Models M22-VT, M22-VTP, M23-VT, M23-VTP Instruction Manual Document
More informationHydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual
Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:
More informationSanitary RTDs and Temperature Transmitters
SENSORS FOR FOOD AND LIFE SCIENCES. Product Information - SA/CT FOOD Sanitary RTDs and Temperature Transmitters Introduction Anderson-Negele s electronic temperature sensors combine our industry proven,
More informationGE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual
GE Sensing PanaFlow MV Vortex Flowmeter User s Manual GE Sensing Panaflow MV Vortex Flowmeter User s Manual 910-279A June 2007 Warranty Each instrument manufactured by GE Sensing, Inc. is warranted to
More informationVorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual
Table of Contents VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters Models M22-VT, M22-VTP, M23-VT, M23-VTP Instruction Manual Part Number IM-22-VT, VTP, IM-23-VT,VTP 04/05 8475 W-I25
More informationPFS-FN FEATURES: * ASME & ISO RECOGNIZED * * WIDELY ACCEPTED TEST STANDARD * * RELIABLE PERFORMANCE HISTORY * * ACCURATE METERING SOLUTION *
FEATURES: * ASME & ISO RECOGNIZED * * WIDELY ACCEPTED TEST STANDARD * * RELIABLE PERFORMANCE HISTORY * * ACCURATE METERING SOLUTION * * FLEXIBLE DESIGN & MATERIALS * 2 PFS FLOW NOZZLE TYPES PFS-NZF PFS-NZFT
More informationHydro-Flow Model 2200 Installation and Operation Guide B
Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical
More informationSITRANS F X SITRANS FX300 3/355
Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure
More informationRosemount 1195 Integral Orifice Primary Element
September 2014 Rosemount DP Flow Rosemount 1195 Integral Orifice Primary Element Rosemount 1195 Integral Orifice Primary Element utilizes a self centering orifice plate design to eliminate installation
More informationSuggested Specifications
ISO 9001 Certified Suggested Specifications The Milliken criteria of quality, reliability, safety and value are embodied in the Millcentric Eccentric valve, setting higher standards for dependable performance
More informationORIFICE PLATE flow meters
ORIFICE PLATE flow meters 1 Differential pressure and pressure loss When a throttle element is interposed in a closed passage of fluid in piping, a difference is produced between the pressure upstream
More informationHydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual
Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:
More informationFLANGE. Flanges used for
FLANGE FLANGE Flanges with rating class designations 150, 300, 400, 600, 900, 1500, and 2500 in sizes NPS 1 2 through NPS 24 ASME B16.5: Pipe Flanges and Flanged Fittings (NPS 24 ) ASME B16.47: NPS 26
More informationDVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102
Vortex Flow Meter DVH / DVE Instruction Manual Page 1 of 102 Contents 1 IDENTIFICATION... 5 1.1 Supplier / Manufacturer... 5 1.2 Producttype... 5 1.3 Issue date... 5 1.4 Version No.... 5 1.5 Tagging /
More informationDIGIFLO ELECTRONIC FLOWMETER
DIGIFLO ELECTRONIC FLOWMETER PIPE FITTING INSTALLATION MANUAL SADDLE MACHINED IN-LINE BODY MOLDED IN-LINE BODY MOLDED TEE Blue-White R Industries, Ltd. F-2000 Page 2 1.0 Temperature vs. Pressure Temperature
More informationResistance thermometer Model TR10-E, for additional thermowell
Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry
More informationClass 300, Welding Neck, Slip-On and Threaded B16.47, Ser. A. ASME B16.5 Flanges
Class 300,, Slip-On and Threaded B16.47, Ser. A ASME B16.5 Flanges Weld, Slip-On, Socket Weld, Threaded, Lap Joint, Blind. 1/2" - 24" Class 150, 300, 400, 600, 900, 1500 and 2500 NOTE: Reducing flanges
More informationSanitary RTDs and Temperature Transmitters
Sanitary RTDs and Temperature Transmitters Modular components provide maximum configuration flexibility Unique element-to-housing design eliminates exposed threads, lowers profile All stainless steel construction
More informationInjection/Sample Quills
Injection/Sample Quills Retractable injection quills are devices that deliver chemicals to a desired location inside piping. Generally, quills are used when relatively small amounts of chemicals are being
More informationKOBOLD KSK FLOWMETER. User Instructions
KOBOLD KSK FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSK_manual_rev. 2/10
More informationPt100 Sensors for Ships
DWR 6010 Vibration proof resistance 8mm Moveable 1/4"BSP compression fitting. Mounting direct or with a thermowell depending on the application. Available with relevant marine Type DWR 6010 DWR 6022 Vibration
More informationFlow Measurement SITRANS F X SITRANS FX300 4/365
Siemens AG 200 Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.
More informationTemperature Sensor without thread
1 Product Information TFP-49, -169, -189, -06 Temperature Sensor without thread Application / Specified Usage Authorizations Installation in thin-walled pipes and vessels No product contacting of the sensor
More informationKOBOLD DF-WM Flow Monitor. User Instructions
KOBOLD DF-WM Flow Monitor User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-DF-WM_12-13 DF-WM Table
More informationModel 3200 Liquid Level Controller
Model 3200 Liquid Level Controller The Model 3200 Liquid Level Controller is ideal for oilfield scrubber and separator applications. Its rugged and versatile design make it the preferred choice of production
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationFLANGES PRODUCT: STANDARD FLANGE CLASSIFICATION: PRESSURE CLASS CLASIFICATION:
FLANGES Gestión de Compras manufactures and supplies flanges according to standards ANSI, BS, DIN, JIS and ISO as well as according to customer specifications. PRODUCT: Flanges are a pipe fitting which
More informationFactors Influencing the Performance of Ball and Rolling Bearings
Factors Influencing the Performance of Ball and Rolling Bearings Course No: M02-033 Credit: 2 PDH Robert P. Tata, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY
More informationL Standard Parts for Mould Making
A Die Sets B Precision Ground Plates and Flat Bars C Lifting and Clamping Devices Shanks, Lifter Studs and Lifting Hooks, Eyebolts Clamping Claws, Screws and Bolts D Guide Elements E Ground Precision Components
More information3000 lb Socket Weld Fittings - ANSI B16.11/BS 3799
Weld and Threaded Fittings 3000 lb Weld Fittings - ANSI B6./BS 3799 /8 /4 3 /8 / 3 /4 /4 / / 3 4 Centre to Bottom of 45 Tees, & Elbows Bore Diameter Bore Diameter of Fittings Thickness s - Average socket
More informationInstruction and Installation Manual
Instruction and Installation Manual ROSTA Tensioner Devices Tensioners Accessories -G -W -R Sprocket wheel N Chain rider P Oil resistant Up to + 120 C Reinforced Sprocket wheel set Chain rider set -I -F
More informationExplosion-Proof ORDER CODES 8HN 74, T- R1T185L 48 3
Explosion-roof Explosion-roof, Fixed-Element RTDs are made for use in.. and Canadian hazardous areas. They are designed to extinguish flames inside the device, eliminating the potential for ignition of
More informationGuide units. For toolmaking, fixture manufacturing and machine engineering
Guide units For toolmaking, fixture manufacturing and machine engineering Guide units in compliance with DIN, ISO and STEINEL standards or according to your specifications Guide pillars Guide and pillar
More informationComparison Chart. extremely difficult. Finally, separated components can rarely be re-used.
JAN 2014 Traditional Connections Why Go Keyless Keyed Bushing Systems Both QD and Taper-Lock bushing and weld-on hub systems are popular component mounting technologies. Yet both are ultimately keyed connections
More informationKOBOLD DAA FLOW INDICATOR. User Instructions. DAA_manual_12-13
KOBOLD DAA FLOW INDICATOR User Instructions DAA_manual_12-13 DAA KOBOLD DAA FLOW INDICATOR User Instructions CAUTION: For safety reasons, please read the cautionary information located at the end of the
More informationVORTEX IN-LINE FLOW METERS
VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase
More informationA Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. FORGED. Gate, Globe & Check Valves.
A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. FORGED Gate, Globe & Check Valves. VALVITALIA VITAS DIVISION PLANT Some production example of Forged Steel Valves 2 Valves
More informationMODEL 45 SCRAPER INDEX
MODEL 45 SCRAPER HOW TO ORDER PARTS: Be sure to state MODEL and SERIAL NO. of machine, PARTS NO., DESCRIPTION, and QUANTITY wanted. Unless this is done, we cannot provide prompt service or assure shipment
More informationBELOW-THE-HOOK & MATERIAL HANDLING EQUIPMENT
BELOW-THE-HOOK & MATERIAL HANDLING EQUIPMENT lifting EQUIPMENT Tongs HBTF Bar Tong Fixed... Page 62 TONGS HBTA Bar Tong Adjustable... Page 63 lifting EQUIPMENT HBTF BAR TONG FIXED FEATURES This style of
More informationResistance thermometer Model TR10-L, Ex d, for additional thermowell
Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical
More information7/8/2015. Vehicle/Equipment Maintenance. Blocking, Cribbing, & Bracing. Lock Out / Tag Out (LOTO) General Best Practices
Vehicle/Equipment Maintenance Blocking, Cribbing, & Bracing Lock Out / Tag Out (LOTO) General Best Practices Be Prepared! Agricultural industries can be unpredictable. Use the correct equipment for the
More informationWith PA Series Transmission: S101 Series Midship Pumps: With C20 Series Transmission:
S100 Series C10 Chain Drive Transmission Overhaul Instructions Installation Instructions S100 Series Centrifugal Fire Pumps Issue Date Form No. F 1031 Section 3017 09/25/02 Rev. Date 04/26/13 IL3292 Table
More informationVortex In Line Flow Meter
Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase
More informationInstruction Manual Vortex Flow Meter DVH / DVE
Instruction Manual Vortex Flow Meter DVH / DVE Customer Notice for Oxygen Service Unless you have specifically ordered Heinrichs` optional O 2 cleaning, this flow meter may not be fit for oxygen service.
More informationModel 5000 Vortex Meter
Model 5000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...
More informationDIAL SIZE Select a dial size that allows you to comfortably read the dial from the normal distance when installed.
53 RANGE The maximum operating pressure should not exceed 75% of the full-scale range. The normal operating range should be in the middle half of the range (between 25% and 75% of the fullscale range);
More informationTemperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product
Series TCM Multipoint Thermocouple Assemblies Multipoint Thermocouples are used in a broad range of processes and installations to monitor the temperature in multiple positions or elevations. These sensors
More informationSierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual
Series 24-HP Instruction Manual Table of Contents Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters Models 240-VT, 240-VTP, 241-VT, 241-VTP Instruction Manual Part Number: IM-24-HP,
More informationTemperature Sensors. Description. Specification
Description Temperature sensors are used to measuring the temperature for the air conditioning industry. This document shows the enclosures and temperature vs. resistance curves for the standard sensors.
More informationTrack Rollers/ Cam Followers
Track Rollers/ Cam Followers Page Nomenclature...................................... 460 Introduction....................................... 462 Identification....................................... 462
More informationFIELD ADJUSTMENTS THREE POINT 1510HDF, 2010HDF, & 2510HDF DRILL MAINTENANCE
FIELD ADJUSTMENTS THREE POINT 1510HDF, 2010HDF, & 2510HDF DRILL MAINTENANCE Proper servicing and adjustment is the key to the long life of any farm implement. With careful and systematic inspection of
More informationBELOW-THE-HOOK & MATERIAL HANDLING EQUIPMENT
BELOW-THE-HOOK & MATERIAL HANDLING EQUIPMENT lifting EQUIPMENT HRLB ROLL LIFTING BEAM...Page 44 HMRL MOTORIZED ROLL LIFTER...Page 45 HRGT ROLL GRIPPING TONGS...Page 46 HRLCH ROLL LIFTING C-HOOK...Page
More informationPlumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs
Plumbing Hale offers a wide variety of plumbing components to make the pump installation and operation easier for the OEM and End User. Hale controls allow for a clean and compact pump panel. Controls
More informationBall splines can be configured for an endless number of automated operations. Demystifying Ball Spline Specs
Ball splines can be configured for an endless number of automated operations. Demystifying Ball Spline Specs Place a recirculating-ball bushing on a shaft and what do you get? Frictionless movement of
More informationVITALink Taped Splice Pigtail Crimp
A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice
More informationThermowell with threaded flange (solid-machined) Screwed and welded design Models TW10-S, TW10-B
Temperature Thermowell with threaded flange (solid-machined) Screwed and welded design Models TW10-S, TW10-B WIKA data sheet TW 95.11 Applications Petrochemical industry, on-/offshore, plant construction
More informationTemperature Sensors. NTC Thermistors. Descriptions. RTS-Raw 10K NTC Thermistor. Specifications: Dimensions (mm):
NTC Thermistors Descriptions In many industrial sectors and fields of research, temperature is one of the most important parameters which decides about product quality, security, and reliability. Temperature
More informationVB VALVES & AUTOMATION
Introduction to Valve What are Valves? Valves are mechanical device that controls the flow and pressure within a system or process. They are essential components of a piping system that conveys liquids,
More informationImmersion Temperature Sensors
Overview The Immersion Temperature Sensor is made for thermowell mounting and temperature measurement in water pipes, water tanks or cooling tower sump applications. The rigid probe is made of Stainless
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS WARNING: NEVER EXCEED YOUR VEHICLE MANUFACTURER'S RECOMMENDED TOWING CAPACITY PIN-STYLE TRUNNION BAR WEIGHT DISTRIBUTION KIT MAINTENANCE Keep the socket-mounted ends of the spring
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationINSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE
INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE Page 1 of 13 1.1 General CHAPTER 1 - GENERAL INFORMATION This manual contains maintenance instructions with pertinent
More information240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual
Sierra 240/241Series Instruction Manual Table of Contents 240/241 Series Vortex Volumetric and Mass Flow Meters Models: 240-V, VT, VTP, LP / 241-V, VT, VTP, LP, Cryogenic Instruction Manual Document Number
More informationUniversal cylinders. single acting with spring return 5 to 100 tonnes. Features. Applications
Universal cylinders YS Universal cylinders single acting with spring return 5 to 100 tonnes Universal cylinders are designed and manufactured to work in the toughest environments to which this type of
More informationEnhanced Heat Transfer Surface Development for Exterior Tube Surfaces
511 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 32, 2013 Chief Editors: Sauro Pierucci, Jiří J. Klemeš Copyright 2013, AIDIC Servizi S.r.l., ISBN 978-88-95608-23-5; ISSN 1974-9791 The Italian
More informationWater Storage Tanks Price List
Water Storage Tanks ist February 2016 ist ZWWP- 020116 February 1, 2016 Supercedes ist ZWWP-020115 (February 1, 2015) www.zcl.com Single-Wall and Double-Wall Tanks Tank Nominal itres Single-Wall Base Tank
More informationt o d o d e BRIDAS VÁLVULAS TUBERÍA
ANSI B16.5 Class 150 Forged Flanges Nom. Pipe O T1 R X No.2/ of L21 H B23 L B R L34 B3 D ½ 3. 5 0. 4 4 1. 3 8 1. 1 9 4-0. 6 2 2. 3 8 1. 8 8 0. 8 4 0. 6 2 0. 6 2 0. 8 8 0. 1 2 0. 6 2 0. 9 0. 3 8 ¾ 3. 8
More information6A-1773 Q ISO-2944
6A-1773 Q1-2801 ISO-2944 Lowery Well Heads, Inc. Quality is #1 We are happy to announce that as of 9-11-15 we are now API Q1 and ISO 9001 certified. Lowery Well Heads, Inc. is committed to its customer
More information