ZR Series ZR24 2' x 4' LED Troffer

Size: px
Start display at page:

Download "ZR Series ZR24 2' x 4' LED Troffer"

Transcription

1 ZR Series ZR24 2' x 4' LED Troffer Product Description The ZR24 LED troffer delivers up to 5000 lumens of superior 90 CRI light quality and is perfect for both new construction and renovation. Powered by Cree TrueWhite Technology, the slim and lightweight ZR24 LED troffer boasts an efficacious LPW performance along with 0-10V dimming to meet local energy codes. The ZR24 LED troffer embodies a breakthrough in balancing energy savings, visual comfort and initial cost. Performance Summary Utilizes Cree TrueWhite Technology (90 CRI) or available in 80 CRI (FD) Efficacy: LPW Initial Delivered Lumens: 4,000 or 5,000 lumens Input Power: watts 3.9" (99mm) CRI: 90 CRI (Cree TrueWhite Technology), 80+ CRI (FD) CCT: 3500K, 4000K, 5000K Input Voltage: VAC or 347 VAC 23.7" (602mm) Limited Warranty : 10 years Controls: 0-10V dimming to 5% Mounting: Recessed* See for warranty terms * Acceptable for use with standard 9/16 T-Bar or larger when installed per installation instructions. Consult factory for non-standard grid applications 47.7" (1212mm) Accessories Field-Installed Drywall Grid Adapter DGA-24WHT Surface Mount Kit SMK-ZR24 - Not for use with EB14 6' Flexible Power Whip PW-18/4-06-9T-SS Wireless 0-10V Dimming/Switching Interface with Cree Smartcast Technology CIF-10V - For use with luminaires with 10V controls when integral SmartCast isn't available Cree SmartCast Technology Configuration Tool CCT-CWC-1 - One required per project when CIF-10V is selected Ordering Information Example: ZR24-40L-35K-10V ZR24 10V Product Initial Delivered Lumens CCT Voltage Control Options ZR24 40L 44W, 4,000 Lumens 90 LPW 50L 45W, 5,000 Lumens 111 LPW - Available with FD option only 35K 3500K - Available with 40L only 40K 4000K 50K 5000K - Available with 50L only Blank Volt Volt - Available with 40L only 10V 0-10V Dimming to 5% EB14 Emergency Backup lumens --Available on US versions only --Provides 90 minutes of emergency operation FD --Must order when 50L is selected --80 CRI Rev. Date: V5 05/04/2016 US: lighting.cree.com/lighting T (800) F (262) Canada: T (800) F (800)

2 ZR24 2' x 4' LED Troffer Product Specifications CREE TRUEWHITE TECHNOLOGY A revolutionary way to generate high-quality white light, Cree TrueWhite Technology is a patented approach that delivers an exclusive combination of 90+ CRI, beautiful light characteristics, and lifelong color consistency, all while maintaining high luminous efficacy a true no compromise solution. CONSTRUCTION & MATERIALS Durable 22 ga. cold rolled steel housing provides strength and uniformity Ultra-thin 3.9" (99mm) luminaire height and lightweight design effectively target a broad range of plenum spaces and allow for easy installations Luminaire is pre-painted for enhanced smooth finish Includes t-bar clips and holes for mounting support wires (by others) Luminaire sides and ends are hemmed in for safe, easy handling Includes lens gasket to prevent ingress of insects Not for installation within 3" (76mm) of insulation Electrical Data* Initial Delivered Lumens System Watts V Total Current 120V 208V 240V 277V 347V 40L L w/eb14 Option N/A 50L N/A 50L w/eb14 Option N/A * Electrical data at 25 C (77 F). Actual wattage may differ by +/- 10% when operating between V +/-10% OPTICAL SYSTEM Unique luminaire design creates perfect balance of both horizontal and vertical illumination Optimized smooth acrylic lens eliminates pixelation and delivers a low-glare, diffused light distribution Recommended ZR Series Lumen Maintenance Factors (LMF) 1 Ambient Initial LMF 25K hr Projected 2 LMF 50K hr Projected 2 LMF 75K hr Projected 2 LMF 100K hr Calculated 3 LMF ELECTRICAL SYSTEM Cree born components including highly efficacious Cree LED chips along with an integral high-efficiency Cree driver Power Factor: = 0.9 nominal Input Power: Stays constant over life Input Voltage: V or 347V, 50/60Hz Operating Temperature Range: 0 C C (32 F F) Total Harmonic Distortion: <20% 10V Source Current: 0.25mA CONTROLS Continuous dimming to 5% with 0-10V DC control protocol For use with Class 2 dimming systems only. Reference for recommended dimming controls and wiring diagrams REGULATORY & VOLUNTARY QUALIFICATIONS culus Listed Suitable for damp locations Designed for indoor use UL924 (EB option) DLC qualified. Please refer to for most current information RoHS compliant. Consult factory for additional details Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions 0 C (32 F) C (41 F) C (50 F) C (59 F) C (68 F) C (77 F) C (86 F) C (95 F) Lumen maintenance values at 25 C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing 2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times (6X) the IESNA LM total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) 3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) Application Reference Open Space Spacing Initial Delivered Lumens Lumens Wattage LPW w/ft 2 Average fc 8 x 8 8 x x x 12 40L 4, L 5, L 4, L 5, L 4, L 5, L 4, L 5, ' ceiling: 80/50/20 reflectances; 2.5' workplane, open room. LLF: 1.0 Initial. Open Space: 50' x 40' x 10' US: lighting.cree.com/lighting T (800) F (262) Canada: T (800) F (800)

3 ZR24 2' x 4' LED Troffer Photometry ZR24-40L-40K BASED ON DTC REPORT TEST #: G Luminaire photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM IESNA LM specifies the entire luminaire as the source resulting in a luminaire efficiency of 100% Coefficients Of Utilization Zonal Cavity Method RC %: 80 RW %: Zonal Lumen Summary Zone Lumens % Lamp Luminaire N/A 24.4% ,628 N/A 40.1% RCR: ,949 N/A 72.6% ,064 N/A 100% ,064 N/A 100% Effective Floor Cavity Reflectance: 20% Average Luminance Table (cd/m 2 ) Horizontal Angle Vertical Angle 45 1,642 1,772 1, ,580 1, ,480 1,885 2, ,276 2,240 2, ,498 3,203 Reference lighting.cree.com/products/indoor/troffers/zr-series for detailed photometric data 2016 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patent Cree, Cree TrueWhite, SmartCast, and TrueWhite are registered trademarks, and the Cree logo, the Cree TrueWhite Technology logo, and ZR24 are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. The DLC QPL logo is a registered trademark of Northeast Energy Efficiency Partnerships, Inc. US: lighting.cree.com/lighting T (800) F (262) Canada: T (800) F (800)

4 Helios Light Installation Manual

5 Table of Contents System Overview... 3 general information... 4 Safety Notes... 5 Ellipse Pole Installation... 6 ELLIPSE helios INSTALLATION - pole leveling adjustment... 8 PMU HELIOS Pole Installation Light installation for PMU Mount...11 TRACK & TROLLEY HELIOS INSTALLATION WALL & CABINET MOUNT HELIOS INSTALLATION CEILING MOUNTED HELIOS INSTALLATION Column Install Helios LED Unit Install Helios LED Unit Transformer Install Helios quick connect removal Maintenance and Adjustments Electrical Connections Ceiling, Wall, Track, Cabinet Helios Checklist Helios Field Retrofit Addendum Helios Upgrade Kits Helios Upgrade Kits Instruction for Upgrading System Post Mount (PMU) Lights with power supply in base of chair Instruction for Upgrading System Ellipse Lights with power supply in junction box Instruction for Upgrading System Post Mount (PMU) Lights with power supply in junction box Helios Track Upgrade Instructions NOTES Technical Support Technical assistance is available Monday through Friday, Phone: :00 am to 6:00 pm (Eastern Standard Time). Fax: Customer Service:

6 System Overview The Helios dental light uses LEDs to create a beam of light that is reflected and creates a shadow reduced pattern suitable for dentistry. The low voltage light source is mounted in various ways for allowing the user to adjust the position to illuminate the oral cavity. The Helios Dental light is intended for use by dental professionals to illuminate the oral cavity while performing examinations and dental procedures. Agency Model # HL3S HLS System Ellipse Mount --OR-- System Mount Agency Model # HL3S HLS Track Agency Model # TH TH1 Agency Model # HL3U HLU Agency Model # HL3C HLC Unit Mount Ceiling Mount Agency Model # HL3CB HLCB Cabinet Mount Agency Model # HL3T HLT Agency Model # HL3WL HLWL Track Mount Wall Mount r13 3

7 general information Definition of Symbols The following symbols and terms may be used throughout this manual: WARNING: Failure to carefully follow the described procedure may result in damage to the equipment and/or injury to the patient/operator. Risk of electrical shock present. Make sure power is disconnected before attempting this procedure. See operating instructions. (AC) Alternating current. Protective earth (Ground) Manufacturing Date Waste Electrical and Electronic Equipment. Type B Applied part. Conforms with the Essential Requirements of the European Medical Device Directive 93/42/EEC for Class I Devices. Conforms with the Essential Requirements of the European Medical Device Directive 93/42/EEC for Class IIa Devices. Indicates conformity to General Requirements for Safety is certified by Intertek Testing Services. Product Disposal Contact your local authorized dealer for proper disposal of the device to ensure compliance with your local environmental regulations. Interference with Electromedical Devices To guarantee the operational safety of electromedical devices, it is recommended that the operation of mobile radio telephones in the medical practice or hospital be prohibited. Strong EMI sources such as electro surgery units or x-ray units may affect performance. If performance problems occur, move the unit to another electrical circuit or physical location. Incompatible Units or Accessories To guarantee the operational safety and function of this device, the use of unapproved unit or accessories is not advised. Doing so could result in potential hazard. Use authorized accessories and devices only. Working Environment This dental unit is to be used in an office environment only. Product Identification This product can be identified by its product label. This label states the unit model and serial number, electrical specifications, manufacture date and safety classification. Note the SAMPLE labels shown below. DENTAL LIGHT HL3U MN SN MO 230 VAC, 0.6A, 50/60 Hz YR REV 2, 10/3-/12 Conforms to STD. AAMI ES Certified to STD CSA C22.2# DENTAL LIGHT HL3U MN SN Conforms to STD: IEC Conforms to STD: IEC Class 1 Equipment Class 1 Equipment MO 115 VAC, 1.0 A, 50/60 Hz YR REV 2, 10/30/12 Conforms to STD. AAMI ES Certified to STD CSA C22.2# General mandatory action required, important to follow instruction. Not a caution. Warning, strong magnetic field. Off On EC REP Light Switch European Authorized Representative WARNING: This product is intended for use by trained dental professionals only. EC REP Medical Device & QA Services Ltd. 76, Stockport Road, Timperley. Cheshire,WA15 7SN. United Kingdom. Tel: +44 (0) Fax: +44 (0) info@ mdqas.com r13 WARNING: Use only Pelton & Crane replacement parts. All repairs should be performed by an authorized Pelton & Crane dealer and/or their representatives. WARNING: Only authorized service technicians should attempt to service this equipment. Use of other than authorized technicians will void the warranty.

8 Safety Notes As manufacturers of electro-medical products we can assume responsibility for safety-related performance of the equipment only if maintenance, repair and modifications are carried out only by us or agencies we have authorized for this purpose, and if components affecting safe operation of the unit that may be needed are replaced with original parts. We suggest that you request a certificate showing the nature and extent of the work performed, from those who carry out such work, and specify that the certificate show any changes in rated parameters or working ranges, as well as the date, the name of the firm and a signature. Storage Conditions: -55 C to +50 C 10% to 90% Relative Humidity WARNING: Rotational stops are designed for a maximum force limit of 25 lbs. If rotational stops are broken, immediately take the equipment out of use and have the equipment serviced. Operation of damaged equipment could result in injury to the operator and/or patient. WARNING: Failure to install set screws & roll pins per Installation Instructions could result in injury or damage to equipment. WARNING: The Helios light is not to be used in rooms where an explosion hazard exists. WARNING: Power cords and their associated parts cannot be substituted without increased risk of electric shock or fire. we recommend the use of Pelton & Crane replacement parts only! Power cords must be installed by qualified personnel. Make sure all service loops, strain reliefs and cord guards are in place and that line, neutral and ground wires are secured. WARNING: This product must be disinfected before use. WARNING: Failure to disinfect the dental operating light between patients could expose user/patient to cross contamination and bioburden/bio-contamination. Electrical Specifications Volts Cycles Amps 115 VAC 60 HZ 1 A ~ 230 VAC 50 HZ.6 A ~ All fuses are labeled at point of use. Replace fuses only with type and rating as indicated. IEC Medical Device Classification Classification: 1 Type: B Operation Mode: Continuous Splash Protection: IPX0 WARNING: No modification of this equipment is allowed. WARNING: Use a licensed electrician for all wiring. WARNING: To avoid risk of electric shock, this equipment must be connected only to supply mains with protective earth r13 5

9 Ellipse Pole Installation Remove light from packaging Flex Arm 1. Apply grease to both sides of the two needle bearings. 2. Place one flat thrust washer over the top of a needle bearing and another flat thrust washer over the bottom. Repeat procedure for other needle bearing. Upper Pole 3. Place centering washers onto top and bottom of ellipse. Lower pole mount as show. Assemble needle bearings, thrust washers, unit arm washer, lock washer and mounting bolt onto ellipse pole mount. NOTE: Make sure centering washers are properly centered so that they won t be damaged during tightening of bolt. 4. Install lower ellipse pole mount to the chair ellipse support plate (not shown) by tightening mounting bolt to lbs/ft with a 15/16 torque wrench. Mounting bolt must be tightened securely and give adequate resistance through entire pole swing range of motion. 5. Snap on cap over bolt head and unit arm washer. Lower Lower Pole 6. Connect both power and signal cables from Flex Arm to the cables in the upper pole. Install remaining exposed cables into pole. Ellipse Pole Mount Centering Washer Thrust Washer Needle Bearing* Thrust Washer Cap Unit Arm Washer Thrust Washer Needle Bearing Thrust * Washer Centering Washer Ground Screw Mounting Lock Washer Bolt Route the low voltage power cable as shown and connect. 7. Align detent in flex arm hub with upper pole long set screw. (short set screw is on opposite side of detent). Insert Flex Arm into pole. Verify long set screw is still aligned with detent and tighten both set screws. NOTE: Detent position can be changed for left or right handed practitioners. If the opposite hand is desired, switch long and short set screws. Rotate detent to opposite side and retighten set screws r13

10 Ellipse Pole Installation 8. Take the plastic packaging sleeving from the light pole, and use it to wrap around and tie together the flex arm and upper light pole (to prevent the flex arm from swinging around during the following assembly step). 9. Lift light and upper pole together, feed wires into lower pole and insert upper pole into lower pole. Pull out cables from other end. 10. Add sleeving braid over ends of cables from umbilical cables going to light (power and ground). Figure Connect both power and signal cables to chair umbilical cables. Connect ground wire to ground screw in lower ellipse pole mount. 12. Route cables properly bayonet as shown. Swing ellipse poles throughout full range of motion and ensure cables move freely with no binding. Route any excess cables inside light pole. 13. Remove plastic packaging sleeving. See Maintenance & Adjustments for final installation; Check Light for Operation r13 7

11 ELLIPSE helios INSTALLATION - pole leveling adjustment Figure 1 Set Screw (A) Set Screw (B) POLE LEVELING ADJUSTMENT 1. Begin by setting up the chair in its final location. Remove poles and arm from shipping box. Leave the strapping tape in place on the flex arm for now. Remove packing on vertical pole only. Figure 2 Chair Mount Set Screw (B) Bayonet Bolt (C) 2. Take the lower ellipse pole and insert bayonet end into the chair mount until fully engaged (Figure 1). Set screws should be seated in chair mount holes and lower ellipse pole will be supported on its own. 3. Attach levels on vertical posts, 90 degrees apart so they will measure front to rear leveling and side to side leveling. Use a hex tool to adjust front set screw (A) to level the posts from front to back (Figure 2). Adjust the side set screws (B) to level the posts from front to rear. When the post is level in both directions, tighten bolt (C) to secure the unit to the chair mount (Figure 3) (Make sure pole is still level after tightening bolt). Figure 3 Set Screw (A) 4. Remove all remaining packaging and inspect the unit for damage. 5. Carefully unbundle and unpackage hand pieces. Attach and hang hand pieces in appropriate slots. 6. Loosen the three screws and slide out the tubing cover from the underside of the chair mount (Figure 4). Figure 4 Bolt (C) WARNING: Before making any connections, be sure all power has been disconnected. Making connections while chair or unit is connected to power source may result in equipment damage or injury. WARNING: This line is intended for low voltage use only. Use of this line is at the discretion of the end user. Screws Tubing Cover r13

12 SPIRIT ELLIPSE HELIOS INSTALLATION Pole Leveling Adjustment Figure 5 Ground Wire 7. Install supplied cable braid sleeving over cables. 8. Connect the light communication cable and low voltage cables (Figure 5). These connections should be made with their mating connectors. As with all electrical connections, care should be taken for proper alignment to prevent damage and ensure proper electrical contact. 9. Connect ground wire to bayonet as illustrated (Figure 5). 10. Once all connections are made, put on cable braid sleeving over visible bundles and push any excess lines and cables back into poles. Rotate ellipse poles to their worst case position(s) and make sure cables have enough slack to move properly with rotations. 11. Replace tubing cover and tighten the (3) screws that were loosened earlier (Figure 6). Low Voltage Power Connector Light Communication Cables Figure r13 9

13 PMU HELIOS Pole Installation 1. Remove lights from packaging. Connect both power and signal cables from flex arm to the cables in the pole. Install remianing exposed cables into pole. 2. Align detent in flex arm hub with upper pole long set screw (small set screw is on opposite side). Insert flex arm into pole. Verify long set screw is still aligned with detent and tighten both pole set screws. NOTE: Detent position can be changed for left or right handed practicioners. If the opposite hand is desired, switch long and short set screws, rotate detent to opposite side and retighten set screws. 3. Take the plastic packaging sleeving from the light pole and use it to wrap around and tie together the flex arm and the pole (to prevent the flex arm from swinging around during the following assembly steps). 4. Install Dress Ring in proper orientation over bottom of ligh pole. 5. Lift light and pole together and feed wires into PMU and insert light pole in middle position. For 1500 PMU only: Slide washer onto the bottom of the pole and install locking ring. 6. Make connections to moving cables inside PMU. 7. Remove plastic packaging sleeving. 8. See maintenance and adjustments for final installation. Check light for operation. Install Shroud r13

14 Light installation for PMU Mount For 1500 PMU 1. Locate and unpack upper light pole and light arm assembly. Have an assistant hold upper pole in place and route light cable through upper pole as shown. Install light arm assembly into top of upper pole. 2. Ensure that the Dress Ring is assembled on the pole 3. Insert pole into the center hole of the PMU. 4. Slide washer onto the bottom of the pole and install locking ring. 5. Connect wiring inside the PMU For 3000 PMU 1. Ensure that the Dress Ring is assembled on the pole. 2. Insert the pole into the center hole of the PMU 3. Connect wiring inside the PMU Dress Ring Washer Retaining Ring }1500 PMU only r13 11

15 TRACK & TROLLEY HELIOS INSTALLATION WARNING: Connection to be made by a qualified electrician. Pre-Installation of Electrical Wiring 1. Stub out a 115 VAC, 60 Hz (or 230 VAC 5DHZ) electrical supply. See position of transformer box. Protect circuit with an appropriate fuse or circuit breaker. 2. Stub out wiring 39-3/16 (99.5 cm) from the chair center line along the long axis of the track and trolley assembly. note: For electrical supply connection, use wiring suitable for at least 90 C (194 F). NOTE: The maximum ceiling height the light may be mounted to is 10 ft. 3. Ensure green/yellow ground wire is grounded at ground screw. 4. Install wall switch between power supply and light power supply transformer. This provides for safety and convenience during installation or service. Wall switch can be switched OFF during electrical storms to prevent transformer damage caused by voltage overloads. Wire nuts are furnished. * If installing a monitor, See Monitor Installation Manual for correct ceiling height r13

16 TRACK & TROLLEY HELIOS INSTALLATION (2) #8 x 3/4" PH Slotted Screws 4(J) Dress Cover 1(E) End Cap 1(F) (2) #10 x ½" Round Head Screws 2(I) End Cap 1(F) (2) #8 x 3/4" PH Slotted Screws 3(J) Power Cord (underneath trolley) (M) Dress Cover 1(E) Trolley 1&5(G) Extrusion Panels 1(D) Track Channel 1(A) Side Stops 5(K) Cover(X) Side Stops (L) 1. The track and trolley are shipped completely assembled. The track channel (A) is mounted to a pallet. Two extrusion panels (D), two dress covers (E), two end caps (F) and Light trolley (G) are attached to the channel. NOTE: DO NOT remove side stops (L). Disconnect power cord (M) at trolley bracket leaving cord intact under extrusion panel (D). Remove trolley off of track. Set aside. 2. To reach the eight 17/64 (7mm) diameter predrilled mounting holes (H) (see next page) in the plywood pallet (C), detach the two end caps (F) by removing two #10-24 x 1/2 round head screws (I) from each end. Set end caps and screws aside. Remove transformer cover (X) from track. 3. Remove two #8 x 3/4 pan head slotted sheet metal screws (J) from each dress cover. Lift away dress covers. Set aside the screws. 4. Identify the eight 17/64 (7mm) diameter predrilled mounting holes (H) in plywood pallet (C) on next page. 5. For easier installation, detach the trolley (G) from the channel before mounting the pallet. Remove the two stops (K) from the end of the track channel opposite the transformer box r13 13

17 TRACK & TROLLEY HELIOS INSTALLATION 1/4" Dia. X 4" Long Lag Bolt for mounting holes (Not Furnished) 2-13/16" 64" 42-11/16" 21-5/16" 11/16" 10" 8-1/2" Pallet Pallet 2&4 (C) 76-13/16" Mounting Holes Ø 17/64" 2 & 4(H) C L of Chair 5/16" (.79 cm) Holes- 8 places 8-3/16" (20.8 cm) 31" (78.7 cm) 33" (83.8 cm) 5" 8-1/2" (21.59 cm) 10" (25.4 cm) 1-13/16" (4.6 cm) 64" (162.6 cm) 39-3/16" (99.5 cm) 76-13/16" (195.1 cm) r13

18 TRACK & TROLLEY HELIOS INSTALLATION Track Framing and Trolley Installation Mounting Pallet to Perpendicular Wood Joists 6. Ensure ceiling substructure is firmly secured to support approximately 200 pounds (100 kg) live load. * If a monitor is being installed with a light, consult monitor literature. 7. Using eight pre-drilled holes in plywood pallet (3/4 x 10 x 76-13/16 ) mount to perpendicular wood joists with eight 1/4 x 4 lag bolts. NOTE: Drill additional holes if necessary. Ensure mounting pallet is level. 8-1/2" (21.59 cm) 60" (152.4cm) Min. 64" (162.6 cm) Max. Perpendicular Wood Joists *Optional Monitor Mount Mounting Pallet to Parallel Wood Joists 8. Contractor to install cross bracing between the parallel joists as shown. Ensure ceiling substructure is firmly secured to support approximately 200 pounds (100kg) live load. 9. Using eight pre-drilled holes in mounting pallet mount to cross bracing with eight 1/4 x 4 lag screws. 10. Reinstall Trolley on Track, plug in power cable and reinstall side stops (shown on page 9). NOTE: Drill additional holes if necessary. Ensure mounting pallet is level. Bracing added by contractor *Optional Monitor Mount 8 x 5/16 Holes 8-1/2" (21.59 cm) 60" (152.4cm) Min. 64" (162.6 cm) Max. Provide adequate framing to support at least 200 pounds (100kg) live load. For ceilings constructed using wood joist, the tripod must bolt directly to the ceiling joists and additional framing or cross blocking using the provided hardware (3 bolts must be used). For other types of ceiling construction, such as suspended ceilings, it will be necessary for installer to provide adequate framing to support at least 200 pounds (100kg) live load that will be secured to ceiling structure before attaching the tripod to framing. If tripod or frame is bolted to concrete or metal, the installer must provide the necessary bolts, anchors and washers to secure frame and/or tripod to ceiling structure r13 WARNING: It is the responsibility of the dealer/contractor to provide suitable support framing prior to installation. 15

19 TRACK & TROLLEY HELIOS INSTALLATION 1/8 Drill Bit with Stop 5/8" depth 2 Magnalube NOTE: For quick connect removal see pages WARNING: Failure to use the supplied drill bit with stop to control depth of drill bit may result in electrical wiring damage and subsequent electrical shock. NOTE: Ensure column is plumb to prevent trolley from drifting. Adjust pallet with shims if necessary. WARNING: Set screws must be tightened securely and roll pins must be installed to prevent column from unscrewing during operation. Failure to install roll pins and tighten set screws securely could result in light falling off trolley r13

20 TRACK & TROLLEY HELIOS INSTALLATION Track Light installation (See page 13 for Illustration) 1. Remove the adapter from the column and set aside. See Maintenance & Adjustments for final installation; Check Light for Operation. 2. Connect power cable from trolley to the power extension cables provided within the column. Apply grease (*) to threads on column. Thread column onto trolley. 3. Insert and tighten two set screws (found within the hardware kit sent inside the column) in trolley to secure column. 4. Using 5/64 Allen Wrench, loosen the two upper set screws on adapter. 5. Apply grease (*) to threads on column. Thread Adapter onto Column and apply Magnalube grease (*) to stem. 6. Connect wire from Column to wire in Flex Arm, push the QC Collar to the installation position and install Stem into Knuckle while pushing wires into Column. 7. Align rotational stop pin (located on flex arm knuckle) with vertical alignment sticker on hub. Slide flex arm knuckle up onto stem until the two clamps in the Knuckle snap into place in the groove on the Stem. Pull the QC Collar to the locked position (it must fully cover the clamps in the Knuckle). 8. Ensure rotational stop is in correct position, and tighten set screws on adapter. 9. Locate two 3/32 pilot holes on the trolley and the adapter; using the supplied drill bit with stop, drill 1/8 hole to a depth of 5/8. Insert roll pins (found within the hardware kit sent inside the column) r13 17

21 WALL & CABINET MOUNT HELIOS INSTALLATION Embed Screw at least 2-1/2" (6.4 cm) into wood 2-1/2" (6.4cm) NOTE: The wallboard is drilled to mount on 16 centers. Locate two studs and mark the locations. 17/64" (.57 cm) dia. 3/4" (1.9 cm) 1/4" (.63cm deep) Rotational Stop Clamp 6 6 WARNING: Use a licensed electrician for all wiring r13

22 WALL & cabinet MOUNT HELIOS INSTALLATION Provide adequate framing to support approximately 200 pounds live load. Framing should allow all four mounting bolts to enter solid wood. Provide a 1.0 amp, 115VAC, 60HZ supply and protect it with a 15 amp fuse or breaker. Install wall switch between power supply and light power supply transformer. This provides for safety and convenience during installation of service. Wall switch can be switched OFF during electrical storms to prevent transformer damage caused by voltage overloads. Wire nuts are furnished. NOTE: Steps 1 through 4 are for Wallboard Installation only: 1. Position wallboard over the located studs with the lower marks 60 from the floor. 2. Position a level over wallboard. Using the centerlines, verify that marks are level. Mark holes using an awl or scribe by piercing the wall through the hole. 3. Drill pilot holes 1/4 diameter in the wall at the marked position. 4. Insert the four 3/8 lag bolts into the concave washers. Be certain the bolt heads fit inside the concave depression on the washer. Mount the wallboard with the lag bolts and snap the bolt head covers on the washer flanges. 5. Connect the power supply to the transformer terminal strip, line, neutral and ground. Wall & Cabinet: 6. Locate the mounting bracket. Line up holes in the bracket with the holes drilled in the cabinet wall. Install transformer mounting bracket using the four 1/4-20 bolts and washers making sure the mounting bracket is level. NOTE: If ceiling clearance is less than 104, slide the Pole into the Mounting Bracket before fastening Mounting Bracket to structural channel. 7. Place nylon washer and rotation stop clamp on pole (mount end) and install pole pivot adapter into the mounting bracket. 8. If required, turn the adapter so the rotational stop feature on the stem assembly is turned toward the head of the chair the light is being installed onto. 9. Install the locking key and secure it with the locking screw r13 19

23 WALL & cabinet MOUNT HELIOS INSTALLATION Pole Collar Drop Stem Quick Connect Collar rear Knuckle 13 locking Key 10 Apply Magnalube (*) To stem QC Collar Installation Position post Collar installation position Locking Key Screw Power Cables 13 QC Collar Locked Position Post Collar Locking Set Screw Apply Magnalube grease (*) pack to stem. 11. Place cover onto pole and lightly tighten set screw (using a 5/64 Allen Wrench) to hold collar above the locking key on the pole. 12. Connect the power cables and push connected power cables up into delivery pole. NOTE: For removal of Quick Disconnect, see pages NOTE: The side removable panel on the cabinet is for access to the plug and receptacle for the light. Do not block this panel; the outlet should be easily accessible for disconnection from main power. 13. Push the QC Collar into the installation position. Align rotational stop pin (located on flex arm knuckle) on pole. Slide flex arm knuckle up onto stem until the two clamps in the knuckle snap into place on the groove in the stem. Pull the QC Collar to the locked position (it must fully cover the clamps in the knuckle!). 14. Check rotational stop (rotation stop has two settings 180 apart) and adjust as required. 15. Loosen set screw and slide collar down over locking key until it is just above, but not touching, the QC Collar and tighten set screw. 16. Make final power connection within transformer box. Install transformer box cover. See Maintenance & Adjustments for final installation; Check Light for Operation r13

24 2 2 CEILING MOUNTED HELIOS INSTALLATION ½ Install wall switch between power supply and power supply transformer. This provides for safety and convenience during installation or service. Wall switch can be switched OFF during electrical storms to prevent transformer damage caused by voltage overloads. Wire nuts are furnished. ½ Positioning The recommended ceiling positionsfor various methods of operation are shown. NOTE: The maximum height the ceiling flex arm may be mounted is 10ft. (304.8 cm). ½ 1 Pre-Installation of Electrical Wiring Stub out a 115 VAC, 60 Hz. (or 230 VAC 50 Hz) electrical supply. See position of transformer box. Protect circuit with appropriate fuse or circuit breaker (local codes apply). ½ Right Hand Installation ½ ½ NOTE: For electrical supply connections, use wiring suitable for at least 90 C (194 F). Provide adequate framing to support at least 200 pounds (100kg) live load. For ceilings constructed using wood, joist the tripod must bolt directly to the ceiling joists and additional framing or cross blocking using the provided hardware (3 bolts must be used). For other types of ceiling construction such as suspended ceilings, it will be necessary for installer to provide adequate framing to support at least 200 pounds (100kg) live load that will be secured to ceiling structure before attaching the tripod to framing. If tripod or frame is bolted to concrete or metal the installer must provide the necessary bolts, anchors and washers to secure frame and/or tripod to ceiling structure. 1 WARNING: It is the responsibility of the dealer/contractor to provide suitable support framing prior to installation. Left Hand Installation r13 21

25 CEILING MOUNTED HELIOS INSTALLATION Tripod and Column Installation Drill three 3/16 (4.5 mm) pilot holes to mount lag bolts. Drill three 3/4 (19 mm) holes through ceiling. Secure tripod and ceiling plate to framing with 5/16 x 4 lag bolts and washers. The 3/4 diameter spacers should be in direct contact with the framing. Insert ceiling plate between the 3/4 spacers and adjusting nuts. NOTE: If spacers rest against soft sheetrock, acoustical tile or plaster, the Helios light may be unstable. Spacer (100 KG) Adjustment Nut Tripod Locking set screws Roll Pin WARNING: Set screws must be tightened securely and roll pins installed to prevent column from unscrewing during operation. Failure to install roll pins and tighten set screws securely could result in the Helios Light falling from ceiling. 5/16" x 4" lag bolt (3) Main Power Connection Route incoming electrical supply through the provided cable clamp.connect the line, neutral and ground to the appropriate terminals. Set Screw Collar Set Screw Light Power Cable from Ceiling Mt. Arm r13

26 CEILING MOUNTED HELIOS INSTALLATION 5/8" depth 2 Magnalube NOTE: For removal of Quick Disconnect, see pages WARNING: Failure to install set screws & roll pins per Installation Instructions could result in injury or damage to equipment. WARNING: Failure to use the supplied drill bit with stop to control depth of drill bit may result in electrical wiring damage and subsequent electrical shock. WARNING: Set screws must be tightened securely and roll pins must be installed to prevent column from unscrewing during operation. Failure to install roll pins and tighten set screws securely could result in light falling from ceiling. 11 Apply Magnalube to Stem 12 QC Collar in Installation Position 12 QC Collar in Locked position r13 23

27 Column Install Column Install (See page 23 for Illustration) 1. Connect power extension provided within the column to the tripod cable. 2. Apply grease (*) to threads on column (both ends). Thread the column into the tripod. Insert and tighten the set screws into the tripod securing the column. 3. Remove stop screw from ceiling mount arm collar. Set aside. 4. Install tripod cover and collar loosely onto column. 5. Connect column power cable to ceiling mount arm cable. 6. Push connected cables up into the column. 7. Thread ceiling mount arm collar onto column. 8. Rotate the ceiling mount arm to locate and position the rotational stop. 9. Secure stop screw and set screws into the ceiling mount arm collar. 10. Remove stem assembly from packaging. Thread stem assembly into ceiling mount arm and secure with set screws in arm. 11. Apply Magnalube to stem and connect cable from ceiling mount arm to cable in flex arm. 12. Push the QC Collar to the installation position. Push rear knuckle of flex arm up onto stem until the two clamps in the knuckle snap into place in the groove in the stem. Pull the QC Collar to the locked position (it must fully cover the clamps in the knuckle). 13. Check to ensure stops are in correct location. 14. Locate two 3/32 pilot holes within tripod and collar, using supplied drill bit with stop, drill 1/8 hole to a depth of 5/8. Insert roll pins (found within the hardware kit sent inside the column). 15. Complete installation of tripod cover and cover collar. 16. Secure stop screw in collar and all set screws. See Maintenance & Adjustments for final installation. Check light for operation r13

28 Helios LED Unit Install 1. Install chair mount (supplied separately) with 2 hub adapter onto chair per manufacturer s instructions. 2. Install vertical unit pole (supplied separately) into 2 Pole hub. 3. Level 2 Pole using the set screws located in the hub. Adjust them in or out as needed until the pole is vertical from front to back and side to side. 5. Feed the power cable down into vertical 2 pole as you lift the upper pole over the vertical pole. Insert the pivot into the bushing in the top of the post until the bottom of the elbow of the horizontal arm is flush with the top of the post. 6. Make sure the connector on the end of the power cable is extending out the hole in the bottom of the 2 pole hub. 4. Remove the unit Helios upper pole from packaging. Apply grease (*) to both ends. PIVOT UNIT HELIOS UPPER POLE HELIOS LIGHT/FLEX ARM ASSEMBLY 2 O.D. 38 UNIT LIGHT POLE (SUPPLIED SEPARATELY) 2 POST HUB (SUPPLIED SEPARATELY) LEVELING SET SCREWS r13 25

29 Helios LED Unit Transformer Install 1. Remove transformer from packaging. 2. If the Helios is installed on a chair with a j-box, remove the j-box cover and place the transformer in it. 3. Route the output power cable through the unit umbilical into the chair, then through the chair to the chair mounted pole adapter. 4. If there is no j-box with the chair, locate the transformer in a suitable location on the floor. Use hardware supplied in the attachment tabs to fasten to the floor. 6. Switch on the on/off switch located on the transformer and check Helios Light for proper function. 7. Replace the j-box cover (if applicable) or install the supplied transformer cover as shown. 8. If using the transformer cover, instal the supplied 5/8 I.D. split flex conduit over the power cables to conceal and protect the cables. Trim the split flex conduit to the proper length as needed. 5. Plug the supplied IEC power cable (if unit is 230 volt this cable is not supplied, the appropriate cord will need to be provided depending on the plug type in the region where it is installed) into the transformer connector and then plug the other end of power cable into a grounded outlet receptacle. Transformer Cover Unit Helios Transformer IEC Connector Attachment Tab Flex Conduit On/Off Switch Fuse Holder Supplied Mounting Hardware Output Power Cable r13

30 Helios quick connect removal If removal of the Helios light flex arm is required for service use the following procedure. Q.C. Collar 1. Locate the three notches on the lower edge of the collar. Using a wide-blade, flat screwdriver, gentle pry up on the collar by twisting the tip of the screwdriver blade in the three notches one at a time until the collar is free. Then push up on the collar as shown. Notch WARNING: Do not pry on collar excessively Q.C. Clamp Q.C. Clamp Rear Knuckle 2. Support the light flex arm assembly while performing this step. Either have an assistant support it, or support the flex arm on one shoulder while one hand holds the rear knuckle to balance it. 3. Locate the two Q.C. clamps located in each side of the knuckle. Grasp the clamp on both sides with the tip of the index finger and thumb and pull it straight out to unlock. It may be required to lift up slightly on the light flex arm assembly to get the Q.C. clamps to release. Pull the clamps out only far enough to allow them to rotate slightly sideways. Once rotated, the clamps will catch on both sides of the slot without retracting back into the slot r13 27

31 Helios quick connect removal, Cont d Drop Stem 3. Lift up slightly on the outside end of the flex arm assembly while pulling down on the rear knuckle to remove the light from the drop stem. Power Cable Connectors Rear Knuckle 4. Grasp both power cable connectors and pull apart to disconnect. Lower the light flex arm assembly and carefuilly place it on a suitable surface. 5. Reinstall in reverse order r13

32 Maintenance and Adjustments Tension Adjustment Locations Rotational Tension Adjustment Flex Arm Drift Adjustment Rotational Tension Adjustment Rotational Tension Adjustment (Both Sides) Rotational Tension Adjustment (Both Sides) r13 29

33 Maintenance and Adjustments E E Helios - Trolley Adjustments A B C D F G H D A B If factory-adjusted side rollers become misaligned in shipping, adjustment will be necessary before installing the two side panels (A). 1. Loosen the two adjusting plate screws (B) on adjusting plates (C). 2. Position side rollers (D) against channel (E) and tighten adjusting screws. D C F B C 3. Inspect trolley (F) for smooth movement and repeat necessary adjustments. WARNING: Set screws must be tightened securely and roll pins must be installed to prevent column from unscrewing during operation. Failure to install roll pins and tighten set screws securely could result in the Helios Light falling from ceiling. NOTE: Ensure column is vertical to prevent trolley from drifting. Adjust pallet with shims if necessary. B NOTE: Column stop adjustment must be performed before installation of roll pin (G). 4. Tighten trolley set screws (H) securely. Main Power Connection 1. Route the incoming electrical supply through the provided cable clamp. 2. Connect the line, neutral and ground to the appropriate terminal in the transformer box. Roll Pin Trolley Set Screws r13

34 Maintenance and Adjustments HELIOS Cover Removal Ball Stud Receiver 1. Use screw driver to remove 6-32 screws. 2. Pull cover straight out to disengage ball stud and receiver. Light Flex Arm 6-32 Screw NOTE: Rubber gasket will remain on cover. Cover 6-32 Screw HELIOS Automatic Light Shutoff Adjustment Angle Bar Plunger light switch Automatic light shutoff adjustment 1. Light shuts off at a fixed position as the arm is raised. 2. To adjust Position where the light turns off, loosen two phillips head screws in the angle bar. 3. Angle bar will slide left and right. 4. Moving the bar to the left leaves the light on longer as you raise the arm r13 31

35 Electrical Connections Ceiling, Wall, Track, Cabinet WARNING: Make sure main power is OFF when connecting to terminal strip. WIRING DIAGRAM FOR LED LIGHT * * N G L 4" B R O 4" BLUE 4" B O W N 4" B L U E 4" B R O W N L N L * 1A FUSE 0.6AFUSE 0.6A FUSE 6" GRN/YEL 6" BROWN 6" BROWN 6" BLUE 6" BLUE 6" GRN/YEL 6" BROWN 6" BLUE 6" BLUE 4" 6" BROWN B L U E 4" 230V INTERNATIONAL TRANSFORMER TRANSFORMER TERMINALS TRANSFORMER TRANSFORMER TERMINALS " BLACK "BLACK V STANDARD *230V U.S.A. 1.ADD SECOND FUSE HOLDER. 2.ADD 0.6A FUSE( ). 3ADD 4" BLUE WIRE. L 3.CHANGE LABEL. G L BLACK FROM LED TRIPOD WHITE FROM LED TRIPOD BLACK FROM LED TRIPOD WHITE FROM LED TRIPOD P/N Rev A terminal block is supplied with these configurations for connection of the main power supply. NOTE: For electrical supply connection, use wiring suitable for at least 90 C (194 F). NOTE: The maximum ceiling height the light may be mounted to is 10 ft.* 2. Ensure green/yellow ground wire is grounded at ground screw. 3. Install wall switch between power supply and light power supply transformer. This provides for safety and convenience during installation or service. Wall switch can be switched OFF during electrical storms to prevent transformer damage caused by voltage overloads. * If installing a monitor, see Monitor Installation Manual for correct ceiling height. WARNING: Connections to be performed only by a qualified electrician. TECHNICAL DATA POWER SUPPLY Primary Specifications for Transformer Volts Cycles Amps 115 VAC 50/60 Hz. 1.0 A ~ 230 VAC 50/60 Hz. 0.6 A ~ WARNING: Before making any connections, be sure all power has been disconnected. Making connections while chair or unit is connected to power source may result in equipment damage or injury. Secondary POWER SUPPLY Volts Cycles Amps 24 VAC 50/60 HZ 2.0 A For replacement fuses use: amp fuse amp fuse r13

36 Helios Checklist Verify the following after installation or servicing of the unit: All manuals are present. All labels are present and legible. No mechanical damage on new installations. The arm is balanced and the friction adjustment is adjusted so that the Helios Light has no noticeable drift in the upper and lower positions. If ceiling mount or track mount, check the column at the tripod, trolley and arm adapter that the roll pins are installed to prevent the column from unscrewing. Verify all set screws are secured. The Helios Light can be moved and positioned freely without any drifting. The Helios Light is connected to the appropriate power source. Dispose of all Helios Light and all respective internal components per applicable codes, regulations and directives r13 33

37 Helios Field Retrofit Addendum Helios Upgrade Kits WARNING: The LFII & LFIII power supplies (circuit boards) are not compatible with the Helios Light. Connecting the Helios light to these power supplies will result in damage to the equipment. Note: Although the power cables are compatible with older LFII and LFIII lights, a complete set of new power cables are supplied with the upgrade kit. Pelton & Crane recommends changing these cables when upgrading to a Helios light. Upgrade kits are ONLY available for system (Ellipse and PMU) and LFII & LFIII track lights. All others will require replacement of the entire light. Definitions Power Supply: Power Circuit Board: Contains both the power circuit board and the associated transformer Pertains strictly to the circuit board itself and NOT the transformer General Notes: All Spirit Series chairs can have either a 150 Watt or 300 Watt Power Supply. Spirit Series Dental Chair Power Supply location of Power Supply SP Watt Base of Chair SP Watt Base of Chair SP15, SP18, SP Watt Base of Chair *SP15, SP18, SP Watt Junction (Utility) Box *Requires replacement of the complete power supply. The power supply will be labeled: FOR USE WITH HELIOS & LF SERIES r13

38 Helios Upgrade Kits Section 1: Circuit Board Identification: 150 Watt Circuit Board # Watt Circuit Board # r13 35

39 Helios Upgrade Kits The Helios compatible circuit boards can be identified by the part number and the white 3 pin connector on the board. Instructions for Upgrading System Ellipse Lights with power supply in base of chair. 300 Watt 115 Volt Wiring Transformer Power Circuit Board 1. Raise chair to highest position. 2. Ensure power is disconnected to the chair. 3. Remove existing power supply circuit board (note positions of wiring to board). 4. Install new Helios compatible circuit board. 5. Disconnect power cable under chair seat. 6. Replace light power cord in chair umbilical and install 60 signal cable (3 wire). 7. Remove upper ellipse light and power cable. 8. Remove lower ellipse pole. 9. Replace lower ellipse pole with new pole. 10. See Ellipse light installation instructions Black (top) ST15 Black (top) ST17 1 ST18 3 ST14 5 ST19 7 ST16 ORANGE ST5 YELLOW ST6 BROWN ST9 BLUE ST7 VIOLET/WHT ST3 BLUE/WHT ST2 BLACK ST1 Transformer 300 Watt 230 Volt Wiring Power Circuit Board Black (top) ST15 Black (top) ST17 1 ST18 3 Jumper 5 Jumper 7 ST16 ORANGE ST5 YELLOW ST6 BROWN ST9 BLUE ST7 VIOLET/WHT ST3 BLUE/WHT ST2 BLACK ST r13

40 Instruction for Upgrading System Post Mount (PMU) Lights with power supply in base of chair 1. Raise chair to highest position. 2. Ensure power is disconnected to the chair. 3. Remove existing power supply circuit board (note positions of wiring to board). (Note: see schematic for 300 watt board). 4. Install new Helios compatible circuit board. 5. Disconnect power cable in PMU. 6. Replace power cable from chair base to PMU and install 60 signal cable (3 wire). 7. Remove upper pole from PMU. For 1500 PMU remove retaining clip on post inside PMU. 8. See PMU Light installation. Instruction for Upgrading System Ellipse Lights with power supply in junction box 1. Raise chair to highest position. 2. Ensure power is disconnected to the chair. 3. Remove existing power supply from junction box (note positions of wiring to board). 4. Install new Helios compatible power supply. 5. Disconnect power cable under chair seat. 6. Replace light power cord in chair umbilical and install 60 and 24 signal cable (3 wire). 7. Remove upper ellipse light and power cable. 8. Remove lower ellipse pole. 300 Watt Wiring Transformer Power Circuit Board Black (top) ST15 Black (top) ST17 1 ST18 3 ST14 5 ST19 7 ST16 ORANGE ST5 YELLOW ST6 BROWN ST9 BLUE ST7 VIOLET/WHT ST3 BLUE/WHT ST2 BLACK ST1 9. Replace lower ellipse pole with new pole. 10. See Ellipse light installation r13 37

41 Instruction for Upgrading System Post Mount (PMU) Lights with power supply in junction box 1. Raise chair to highest position. 2. Ensure power is disconnected to the chair. 3. Remove existing power supply (note positions of wiring to board). 4. Install new Helios compatible power supply. 5. Disconnect power cable in PMU. 6. Replace power cable from junction box to PMU and install 60 and 24 signal cable (3 wire). 7. Remove upper pole from PMU. For 1500 PMU remove retaining clip on post inside PMU. 8. See PMU Light installation r13

42 Helios Track Upgrade Instructions 1. Turn power off to track light. 2. Remove existing light and column from trolley. 3. Remove both end caps (2 screws A) and extrusion panels (outside covers, 3 screws B) from track. 4. Remove trolley stops (C) from track (opposite end of the transformer). 5. Slide trolley to end of track and unplug the power cable. 6. Remove trolley from track. 7. Remove cover from transformer box. 8. Disconnect main power to transformer. 9. Standing under transformer remove left inside cover (3 screws D). 10. Remove cable clamp (E). 11. Remove four (F) screws securing the transformer box to the track light pallet and remove transformer box and cable from transformer to trolley. A WARNING: The fuse for the Helios is a 1 amp fuse. DO NOT use fuse from LFII & LFIII. F A B C E D r13 39

43 Helios Track Upgrade Instructions 12. Countersink 4 holes in pallet using supplied template (inside box lid). Align template with existing countersunk holes. 13. Mount Helios transformer box to pallet. 14. Replace cable clamp and run NEW cable (supplied) from transformer to trolley. 15. Reinstall inside cover. 16. Reconnect main power to transformer via transformer terminal strip. 17. Reinstall cover for transformer box. 18. Assemble light onto trolley (see track light installation section). 19. Raise trolley and light sliding onto end of track. 20. Connect power cable to trolley. 21. Reinstall trolley stops. 22. Reinstall both end caps (2 screws) and extrusion panels (outside covers, 3 screws) onto track " 3.43" /8" 1.97" 4.06" 5.75" 8.25" r13

44 r13 41

45 NOTES r13

46 2014 Pelton & Crane Fruehauf Drive Charlotte, NC, USA We reserve the right to make any alterations which may be due to any technical improvements. P/N Rev. 13, 04/29/14 Printed in USA

47 Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Typical applications include corridors, lobbies, conference rooms and private offices. CONSTRUCTION Galvanized steel mounting/plaster frame; galvanized steel junction box with bottom-hinged access covers and spring latches. Reflectors are retained by torsion springs. Vertically adjustable mounting brackets with commercial bar hangers provide 3-3/4 total adjustment. Two combination ½ -3/4 and four ½ knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out). No. 12 AWG conductors, rated for 90 C. Accommodates joist spacing. Passive cooling thermal management for 25 C standard; high ambient (40 C) option available. Light engine and drivers are accessible from above or below ceiling. Max ceiling thickness 1-1/2. OPTICS LEDs are binned to a 3-step SDCM; 80 CRI minimum. LED light source concealed with diffusing optical lens. General illumination lighting with 1.0 S/MH and 55 cutoff to source and source image. Self-flanged anodized reflectors in specular, semi-specular, or matte diffuse finishes. Also available in white and black painted reflectors. ELECTRICAL Multi-volt ( V, 50/60Hz) eldoled 0-10V dimming drivers mounted to junction box, 10% or 1% minimum dimming level available. 0-10V dimming fixture requires two (2) additional low-voltage wires to be pulled. 70% lumen maintenance at 50,000 hours. LISTINGS Certified to US and Canadian safety standards. Damp location standard (wet location, covered ceiling optional). WARRANTY 5-year limited warranty. Complete warranty terms located at Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 C. Note: Specifications subject to change without notice. Notes Type LDN6 6 OPEN and WALLWASH LED Non-IC New Construction Downlight DIMMABLE ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: LDN6 35/15 LO6AR MVOLT EZ10 LDN6 Series Color temperature Lumens 1 Aperture/Trim Color Finish Voltage LDN6 6" round 27/ 2700K lumens lumens LO6 Downlight AR Clear LSS Semi-specular MVOLT Multi-volt 30/ 3000K lumens lumens LW6 Wallwash WR 2 White LD Matte diffuse V 35/ 3500K lumens lumens BR 2 Black LS Specular V 40/ 4000K lumens lumens V Driver Options EZ10 eldoled 10% 0-10V EZ1 eldoled 1% 0-10V SF 4 Single fuse TRW 5 White painted flange TRBL 5 Black painted flange ELR 4 Batterypack (remote) EL 4 Batterypack NPS80EZ 4 nlight dimming pack controls 0-10V eldoled drivers. NPS80EZER 4 HAO CP WL RRL nlight dimming pack controls 0-10V eldoled drivers. ER controls fixtures on emergency circuit. High ambient option Chicago Plenum Wet location RELOC -ready luminaire connectors enable a simple and consistent factory installed option across all ABL luminaire brands. Refer to RRL for complete nomenclature. Available only in RRLA, RRLB, RRLAE, and RRLC12S. Accessories: Order as separate catalog number. EAC ISSM 375 Compact interruptible emergency AC power system EAC ISSM 125 Compact interruptible emergency AC power system GRA68 JZ Oversized trim ring with 8 outside diameter 1 SCA6 Sloped ceiling adapter. Refer to TECH-SCA for more options. Notes 1 Overall height varies based on lumen package; refer to dimensional chart on page 3. 2 Not available with finishes. 3 Not available with emergency options. 4 Must specify voltage 120V or 277V. 5 Available with clear (AR) reflector only. DOWNLIGHTING LDN6

48 LDN6 PHOTOMETRY Consult Factory for Photometry. LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA Phone: Fax: Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/07/16

49 LDN6 * All dimensions are inches (centimeters) unless otherwise noted. LDN LUMEN LDN LUMEN 11 [27.9] 11 [27.9] [26.2] [12.9] [14.5] [26.2] [14.9] [16.5] Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) LDN LUMEN 11 [27.9] [26.2] [14.9] [16.5] Marked Spacing: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) LDN6 CP LDN EL-ELR [38.2] [50.6] [29.3] [34.9] [20.9] [19.7] [48.5] [16.5] 8 [14.9] Marked Spacing above 3000 lumen: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) Marked Spacing above 3000 lumen: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) Notes Tested in accordance with IESNA LM Tested to current IES and NEMA standards under stabilized laboratory conditions. CRI: 80 typical. LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA Phone: Fax: Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/07/16

50 LDN6 ADDITIONAL DATA MANUFACTURER Lutron Leviton Synergy Douglas Lighting Controls Entertainment Technology Honeywell HUNT Dimming COMPATIBLE 0-10V WALL-MOUNT DIMMERS PART NO. Diva DVTV Diva DVSCTV Nova T NTFTV Nova NFTV AWSMT-7DW AWSMG-7DW AMRMG-7DW Leviton Centura Fluorescent Control System IllumaTech IP7 Series ISD BC SLD LPCS Digital Equinox (DEQ BC) WPC-5721 Tap Glide TG600FAM120 (120V) Tap Glide Heatsink TGH1500FAM120 (120V) Oasis 0A2000FAMU EL7315A1019 EL7315A1009 Preset slide: PS-010-IV and PS-010-WH Preset slide: PS-010-3W-IV and PS-010-3W-WH Preset slide, controls FD-010: PS-IFC-010-IV and PS-IFC-010-WH-120/277V Preset slide, controls FD-010: PS-IFC-010-3W-IV and PS-IFC-010-3W-WH-120/277V Remote mounted unit: FD-010 POWER BOOSTER AVAILABLE CN100 PE300 RDMFC EL7305A1010 (optional) Lehigh Electronic Products Solitaire PBX PDM Electrical Products WPC-5721 Starfield Controls TR61 with DALI interface port RT03 DALInet Router WattStopper LS-4 used with LCD-101 and LCD-103 A EL/ELR AVAILABILITY/COMPATIBILITY - INITIAL LUMENS Lumen package Watts Initial lumens EL/ELR Emergency LED driver PS PS PS PS1050 LUMEN OUTPUT MULTIPLIERS - FINISH Clear (AR) White (WR) Black (BR) Specular (LS) 1.0 N/A N/A Semi-specular (LSS) N/A N/A Matte diffuse (LD) 0.85 N/A N/A Painted N/A LUMEN OUTPUT MULTIPLIERS - CCT 2700K 3000K 3500K 4000K 80CRI ncm PDT 9 npodm 2P DX B C A A nps 80 EZ B B C nps 80 EZ WIRING KEY A CAT-5e Cable B Line Power C Low Voltage Dimming Wires ncm ADCX A OPTIONAL nlight Control Accessories: Order as separate catalog number. Visit for complete listing of nlight controls. WallPod stations Model number Occupancy sensors Model number On/Off npodm [color] Small motion 360, ceiling (PIR / dual tech) ncm 9 / ncm PDT 9 On/Off & Raise/Lower npodm DX [color] Large motion 360, ceiling (PIR / dual tech) ncm 10 / ncm PDT 10 Graphic Touchscreen npod GFX [color] Wide view (PIR / dual tech) nwv 16 / nwv PDT 16 Photocell controls Model number Wall Switch w/ Raise/Lower (PIR / dual tech) nwsx LV DX / nwsx PDT LV DX Dimming ncm ADCX Cat-5 cables (plenum rated) Model number 10', CAT5 10FT CAT5 10FT J1 15', CAT5 15FT CAT5 15FT J1 LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA Phone: Fax: Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/07/16

51 Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Typical applications include corridors, lobbies, conference rooms and private offices. CONSTRUCTION Galvanized steel mounting/plaster frame; galvanized steel junction box with bottom-hinged access covers and spring latches. Reflectors are retained by torsion springs. Vertically adjustable mounting brackets with commercial bar hangers provide 3-3/4 total adjustment. Two combination ½ -3/4 and four ½ knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out). No. 12 AWG conductors, rated for 90 C. Accommodates joist spacing. Passive cooling thermal management for 25 C standard; high ambient (40 C) option available. Light engine and drivers are accessible from above or below ceiling. Max ceiling thickness 1-1/2. OPTICS LEDs are binned to a 3-step SDCM; 80 CRI minimum. LED light source concealed with diffusing optical lens. General illumination lighting with 1.0 S/MH and 55 cutoff to source and source image. Self-flanged anodized reflectors in specular, semi-specular, or matte diffuse finishes. Also available in white and black painted reflectors. ELECTRICAL Multi-volt ( V, 50/60Hz) eldoled 0-10V dimming drivers mounted to junction box, 10% or 1% minimum dimming level available. 0-10V dimming fixture requires two (2) additional low-voltage wires to be pulled. 70% lumen maintenance at 50,000 hours. LISTINGS Certified to US and Canadian safety standards. Damp location standard (wet location, covered ceiling optional). WARRANTY 5-year limited warranty. Complete warranty terms located at Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 C. Note: Specifications subject to change without notice. Notes Type LDN6 6 OPEN and WALLWASH LED Non-IC New Construction Downlight DIMMABLE ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: LDN6 35/15 LO6AR MVOLT EZ10 LDN6 Series Color temperature Lumens 1 Aperture/Trim Color Finish Voltage LDN6 6" round 27/ 2700K lumens lumens LO6 Downlight AR Clear LSS Semi-specular MVOLT Multi-volt 30/ 3000K lumens lumens LW6 Wallwash WR 2 White LD Matte diffuse V 35/ 3500K lumens lumens BR 2 Black LS Specular V 40/ 4000K lumens lumens V Driver Options EZ10 eldoled 10% 0-10V EZ1 eldoled 1% 0-10V SF 4 Single fuse TRW 5 White painted flange TRBL 5 Black painted flange ELR 4 Batterypack (remote) EL 4 Batterypack NPS80EZ 4 nlight dimming pack controls 0-10V eldoled drivers. NPS80EZER 4 HAO CP WL RRL nlight dimming pack controls 0-10V eldoled drivers. ER controls fixtures on emergency circuit. High ambient option Chicago Plenum Wet location RELOC -ready luminaire connectors enable a simple and consistent factory installed option across all ABL luminaire brands. Refer to RRL for complete nomenclature. Available only in RRLA, RRLB, RRLAE, and RRLC12S. Accessories: Order as separate catalog number. EAC ISSM 375 Compact interruptible emergency AC power system EAC ISSM 125 Compact interruptible emergency AC power system GRA68 JZ Oversized trim ring with 8 outside diameter 1 SCA6 Sloped ceiling adapter. Refer to TECH-SCA for more options. Notes 1 Overall height varies based on lumen package; refer to dimensional chart on page 3. 2 Not available with finishes. 3 Not available with emergency options. 4 Must specify voltage 120V or 277V. 5 Available with clear (AR) reflector only. DOWNLIGHTING LDN6

52 LDN6 PHOTOMETRY Consult Factory for Photometry. LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA Phone: Fax: Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/07/16

53 LDN6 * All dimensions are inches (centimeters) unless otherwise noted. LDN LUMEN LDN LUMEN 11 [27.9] 11 [27.9] [26.2] [12.9] [14.5] [26.2] [14.9] [16.5] Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) LDN LUMEN 11 [27.9] [26.2] [14.9] [16.5] Marked Spacing: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) LDN6 CP LDN EL-ELR [38.2] [50.6] [29.3] [34.9] [20.9] [19.7] [48.5] [16.5] 8 [14.9] Marked Spacing above 3000 lumen: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) Marked Spacing above 3000 lumen: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap trim: 7-1/2 (19.1) Notes Tested in accordance with IESNA LM Tested to current IES and NEMA standards under stabilized laboratory conditions. CRI: 80 typical. LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA Phone: Fax: Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/07/16

54 LDN6 ADDITIONAL DATA MANUFACTURER Lutron Leviton Synergy Douglas Lighting Controls Entertainment Technology Honeywell HUNT Dimming COMPATIBLE 0-10V WALL-MOUNT DIMMERS PART NO. Diva DVTV Diva DVSCTV Nova T NTFTV Nova NFTV AWSMT-7DW AWSMG-7DW AMRMG-7DW Leviton Centura Fluorescent Control System IllumaTech IP7 Series ISD BC SLD LPCS Digital Equinox (DEQ BC) WPC-5721 Tap Glide TG600FAM120 (120V) Tap Glide Heatsink TGH1500FAM120 (120V) Oasis 0A2000FAMU EL7315A1019 EL7315A1009 Preset slide: PS-010-IV and PS-010-WH Preset slide: PS-010-3W-IV and PS-010-3W-WH Preset slide, controls FD-010: PS-IFC-010-IV and PS-IFC-010-WH-120/277V Preset slide, controls FD-010: PS-IFC-010-3W-IV and PS-IFC-010-3W-WH-120/277V Remote mounted unit: FD-010 POWER BOOSTER AVAILABLE CN100 PE300 RDMFC EL7305A1010 (optional) Lehigh Electronic Products Solitaire PBX PDM Electrical Products WPC-5721 Starfield Controls TR61 with DALI interface port RT03 DALInet Router WattStopper LS-4 used with LCD-101 and LCD-103 A EL/ELR AVAILABILITY/COMPATIBILITY - INITIAL LUMENS Lumen package Watts Initial lumens EL/ELR Emergency LED driver PS PS PS PS1050 LUMEN OUTPUT MULTIPLIERS - FINISH Clear (AR) White (WR) Black (BR) Specular (LS) 1.0 N/A N/A Semi-specular (LSS) N/A N/A Matte diffuse (LD) 0.85 N/A N/A Painted N/A LUMEN OUTPUT MULTIPLIERS - CCT 2700K 3000K 3500K 4000K 80CRI ncm PDT 9 npodm 2P DX B C A A nps 80 EZ B B C nps 80 EZ WIRING KEY A CAT-5e Cable B Line Power C Low Voltage Dimming Wires ncm ADCX A OPTIONAL nlight Control Accessories: Order as separate catalog number. Visit for complete listing of nlight controls. WallPod stations Model number Occupancy sensors Model number On/Off npodm [color] Small motion 360, ceiling (PIR / dual tech) ncm 9 / ncm PDT 9 On/Off & Raise/Lower npodm DX [color] Large motion 360, ceiling (PIR / dual tech) ncm 10 / ncm PDT 10 Graphic Touchscreen npod GFX [color] Wide view (PIR / dual tech) nwv 16 / nwv PDT 16 Photocell controls Model number Wall Switch w/ Raise/Lower (PIR / dual tech) nwsx LV DX / nwsx PDT LV DX Dimming ncm ADCX Cat-5 cables (plenum rated) Model number 10', CAT5 10FT CAT5 10FT J1 15', CAT5 15FT CAT5 15FT J1 LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA Phone: Fax: Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/07/16

55 BATH COLLECTION Kisdon Bath DESCRIPTION Rectangular hand molded glass is set off by sleek die cast metal details in the Kisdon bath light fixture from Tech Lighting. Choice of lamping including LED provides beautiful ambient or up and down light depending on mounting direction. Includes four 120 volt, 60 watt G9 base halogen lamps or 36 watt 2G11 base twin tube compact fluorescent lamps. Incandescent version dimmable with standard incandescent dimmer. Includes 24 watt, 1560 net lumen, 3000K LED modules. LED v ersion dimmable with low voltage electronic dimmer. May be mounted horizontally or vertically. ADA compliant. INSTALLATION Mounts to a standard 4" square junction box with round plaster ring (provided by electrician). WEIGHT 8.1lb / 3.67kg ± white glass antique bronze satin nickel ORDERING INFORMATION 700BCKIS COLOR FINISH LAMP W WHITE GLASS Z ANTIQUE BRONZE C CHROME S SATIN NICKEL INCANDESCENT CF COMPACT FLOURESCENT 120V CF277 COMPACT FLUORESCENT 277V LED830 LED 80 CRI 3000K 120V LED LED 80 CRI 3000K 277V White acrylic not available with incandescent lamp option. 700BCKIS FIXTURE TYPE: JOB NAME: 7400 Linder Avenue Skokie, Illinois T F NOTES: Tech Lighting, L.L.C Tech Lighting, L.L.C. All Rights Reserved. The "Tech Lighting" graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification.

56 BATH COLLECTION Kisdon Bath DESCRIPTION Rectangular hand molded glass is set off by sleek die cast metal details in the Kisdon bath light fixture from Tech Lighting. Choice of lamping including LED provides beautiful ambient or up and down light depending on mounting direction. Includes four 120 volt, 60 watt G9 base halogen lamps or 36 watt 2G11 base twin tube compact fluorescent lamps. Incandescent version dimmable with standard incandescent dimmer. Includes 24 watt, 1560 net lumen, 3000K LED modules. LED v ersion dimmable with low voltage electronic dimmer. May be mounted horizontally or vertically. ADA compliant. INSTALLATION Mounts to a standard 4" square junction box with round plaster ring (provided by electrician). WEIGHT 8.1lb / 3.67kg ± white glass antique bronze satin nickel ORDERING INFORMATION 700BCKIS COLOR FINISH LAMP W WHITE GLASS Z ANTIQUE BRONZE C CHROME S SATIN NICKEL INCANDESCENT CF COMPACT FLOURESCENT 120V CF277 COMPACT FLUORESCENT 277V LED830 LED 80 CRI 3000K 120V LED LED 80 CRI 3000K 277V White acrylic not available with incandescent lamp option. 700BCKIS FIXTURE TYPE: JOB NAME: 7400 Linder Avenue Skokie, Illinois T F NOTES: Tech Lighting, L.L.C Tech Lighting, L.L.C. All Rights Reserved. The "Tech Lighting" graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification.

57 MANHATTAN model: WS-131 dwelled TM LED Wall Sconce Fixture Type: Catalog Number: Project: Location: 7a" 2w" 15", 22 2w, 3" 9" " PRODUCT DESCRIPTION An unequivocal transitional choice for both formal and casual spaces. Beautiful ambient lighting in a luxury residence or boutique hotel. Three ADA compliant sizes are available. FEATURES Trimless fabric shade Etched glass diffuser ADA compliant Meets 2013 California Title 24 Efficiency Smooth and continuous ELV dimming ETL & cetl damp location listed Transformer located in J box 80,000 hour rated life Color Temp: 2700K 90 CRI 277V available (special order) SPECIFICATIONS Construction: Steel ORDERING NUMBER Model# Length Watt LED Lumens Delivered Lumens Finish WS " 6W WS " 10.5W WS " 15.5W BN BR BO PN Brushed Nickel Brushed Brass Brushed Bronze Polished Nickel - Example: WS BO For 277V, add an F before the finish: WS-13107F-BO waclighting.com Phone (800) Fax (800) Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY Central Distribution Center 1600 Distribution Ct Lithia Springs, GA Western Distribution Center 1750 Archibald Avenue Ontario, CA WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. FEB 2015

58 CH LED LED STRIPLIGHT Comparable to 2 32WT8 4 54W T5HO TM 4676 Lumens@43W 20,740 Lumens@172W led striplight The CHLED series of low profile, open LED striplights provides superior energy efficiency and a longer, maintenance-free operating life over the traditional T5 and T8 fluorescent fixtures they are desiged to replace. 4 Foot Using up to 28% less energy and operating for 72,000 hours (L70), CHLED LED striplights are ideal for uplight and downlight in commercial, manufacturing, warehouse, and residential applications, including coves and displays. CHLED is available in 4 and 8 lengths with a choice of 3 lumen packages per size in 3 color temperatures. 8 Foot UPGRADE YOUR LIGHTING WITH LED Whether you re adding new lighting or replacing existing outdated lighting, Simkar s CHLED LED striplights provide illumination, performance, and durability. w w w. s i m k a r. c o m SUPERIOR PERFORMANCE The CHLED Series offers a familiar form with exceptional performance. Used any place a traditional fluorescent strip would be found, the CHLED offers a wide range of lumen outputs and three color temperatures. LONG-TERM RELIABILITY AND OPERATION A 72,000 hour operating life (L70) lets you install the fixtures and expect over 16 years of LED operating life. EXPANDED OPERATION Also offered are great options for mounting, emergency lighting, and dimming, further extending the range of applications that are ideal for the CHLED.

59 CH LEDTM led striplight More light, using less energy up to 28% energy savings vs. fluorescent Longer lasting light; up to 72,000 hour (L70) operating life Heavy gauge steel housing 3500K, 4100K, and 5000K temperatures Control friendly, 0-10V dimming Toolless access LED STRIPLIGHT Wireway secured with tether for convenient installation & maintenance Surface, pendant, stem, or chain mount 120V-277V operation standard C-UL-US Listed DesignLights Consortium (DLC) qualified 5-year limited warranty HOUSING Housing, wireway cover and ends are die-formed heavy gauge steel with high gloss, baked white enamel finish over rust inhibiting phosphate coat. Housing and wireway cover act as heat sink to dissipate heat, maximizing the life of the LEDs and power supplies. Ample knockouts provided on back, ends, and sides. LEDS 4 fixtures available in 3 light level (delivered); 5042 lumens (43W), 6574 lumens (60W) and 10,240 lumens (86W) at 4100K CCT, >80 CRI. Also available in 3500K and 5000K color temperatures. 8 fixtures available in 3 light levels (delivered); 9836 lumens (86W), 13,148 lumens (125W) and 20,480 lumens (172.5W) at 4100K CCT, >80 CRI. Also available in 3500K and 5000K color temperatures. Beam spread is 110 degrees. LEDs are LM-80 tested. Operating life is 72,000 hours (L70) for 43W, 86W and 170W units; 60,000 hours (L70) for 60W and 120W units. Light engines consist of 128, 256 or 512 mid-power LED chips mounted on aluminum core printed circuit boards. LED light engines are replaceable. ELECTRICAL V LED power supply, power factor is > V dimmable, standard. Power supplies are mounted in direct contact with steel housing for cooler operation and longer life. Drive current is 1500mA for 4 ft. fixures (43W, 86W units) and for 8 ft. fixtures (86W, 170W). Drive current is 2100mA for 4 ft 60W and 8 ft. 125W fixtures. One power supply is used in 43W and 60W units. Two power supplies are used in the 86W and 120W units. Four power supplies are used in the 170W unit. Power supplies can be accessed from below and are replaceable. The CHLED series is designed to operate in temperatures of -40 F (-40 C) to 113 F (40 C). ACCESS / WIRING Tooless access to wireway channel. Wireway cover/led tray snaps onto the housing and can be removed wthout tools. LED tray can be secured to housing wih screws (optional). Wireway cover/led tray is tethered to the housing for easier installation and maintenance. Internal plug-in wiring harness. MOUNTING Suitable for surface, pendant, stem, or chain mounting, individualy or in continuous rows. Use accessory CHJ joiner to connect fixtures in continuous rows. LISTINGS C-UL-US listed, damp location. DesignLights Consortium qualified. WARRANTY 5 year limited warranty CHLED LED Striplight Configuration SERIES LENGTH WATTAGE* COLOR TEMPERATURE VOLTAGE OPTIONS ACCESSORIES CHLED 4 = 4' 8 = 8' 4' Units 43 = 43W 60 = 60W 86 = 86W 8' Units 86 = 86W 120 = 120W 170 = 170W 35 = 3500 K 41 = 4100 K 50 = 5000 K * Nominal. See technical specifications for actual input power. U1 = Universal V 347 = 347V 480 = 480V ELS = Emergency Backup, 900lm 6 Cord and Plug CPT(x) 1 = 120V 2 = 277V 3 = 208V 4 = 240V 5 = 480V CP3 = Cord & Plug-120V Straight Blade 5-15P FL4 = 3/8, 6 flex with two #18, one ground and two connectors FL5 = 3/8, 6 flex with three #18, one ground and two connectors C = Single white canopy (for use with pendant mount) CA24 = Chain Hanger Assembly-(2) 18 chains, (2) V hooks, (2) S hooks for total drop 24 CHJ = Housing Joiner (to connect long runs) CS24 = S Hook (4) Chain Hanger Assembly (24 total drop) PM(x) = Pendant Mount, white stem-specify length in inches (24, 36, 48, 60, 72) SN = Snapper Brackets TB4 = T-Bar grid mounting clip WG240 = 48 wire guard (order 2 for 8' units)) Dimensions 2 1/4" 4 1/4" 48" / 96" CHLED Performance K CCT Model Light Output* Input Power Efficacy CHLED44341U1 5,042 lumens watts 116 lpw CHLED46041U1 6,574 lumens watts 105 lpw CHLED48641U1 10,240 lumens watts 121 lpw CHLED88641U1 9,836 lumens watts 114 lpw CHLED812041U1 13,148 lumens watts 105 lpw CHLED817041U1 20,480 lumens watts 119 lpw *Delivered lumens **Consult a lighting engineer to meet specific requirements. LM79 photometric testing pending. Performance based on calculated data RoHS COMPLIANT LED LED Simkar 700 Ramona Avenue Philadelphia, Pennsylvania CHLED

60 CH LED LED STRIPLIGHT Comparable to 2 32WT8 4 54W T5HO TM 4676 Lumens@43W 20,740 Lumens@172W led striplight The CHLED series of low profile, open LED striplights provides superior energy efficiency and a longer, maintenance-free operating life over the traditional T5 and T8 fluorescent fixtures they are desiged to replace. 4 Foot Using up to 28% less energy and operating for 72,000 hours (L70), CHLED LED striplights are ideal for uplight and downlight in commercial, manufacturing, warehouse, and residential applications, including coves and displays. CHLED is available in 4 and 8 lengths with a choice of 3 lumen packages per size in 3 color temperatures. 8 Foot UPGRADE YOUR LIGHTING WITH LED Whether you re adding new lighting or replacing existing outdated lighting, Simkar s CHLED LED striplights provide illumination, performance, and durability. w w w. s i m k a r. c o m SUPERIOR PERFORMANCE The CHLED Series offers a familiar form with exceptional performance. Used any place a traditional fluorescent strip would be found, the CHLED offers a wide range of lumen outputs and three color temperatures. LONG-TERM RELIABILITY AND OPERATION A 72,000 hour operating life (L70) lets you install the fixtures and expect over 16 years of LED operating life. EXPANDED OPERATION Also offered are great options for mounting, emergency lighting, and dimming, further extending the range of applications that are ideal for the CHLED.

61 CH LEDTM led striplight More light, using less energy up to 28% energy savings vs. fluorescent Longer lasting light; up to 72,000 hour (L70) operating life Heavy gauge steel housing 3500K, 4100K, and 5000K temperatures Control friendly, 0-10V dimming Toolless access LED STRIPLIGHT Wireway secured with tether for convenient installation & maintenance Surface, pendant, stem, or chain mount 120V-277V operation standard C-UL-US Listed DesignLights Consortium (DLC) qualified 5-year limited warranty HOUSING Housing, wireway cover and ends are die-formed heavy gauge steel with high gloss, baked white enamel finish over rust inhibiting phosphate coat. Housing and wireway cover act as heat sink to dissipate heat, maximizing the life of the LEDs and power supplies. Ample knockouts provided on back, ends, and sides. LEDS 4 fixtures available in 3 light level (delivered); 5042 lumens (43W), 6574 lumens (60W) and 10,240 lumens (86W) at 4100K CCT, >80 CRI. Also available in 3500K and 5000K color temperatures. 8 fixtures available in 3 light levels (delivered); 9836 lumens (86W), 13,148 lumens (125W) and 20,480 lumens (172.5W) at 4100K CCT, >80 CRI. Also available in 3500K and 5000K color temperatures. Beam spread is 110 degrees. LEDs are LM-80 tested. Operating life is 72,000 hours (L70) for 43W, 86W and 170W units; 60,000 hours (L70) for 60W and 120W units. Light engines consist of 128, 256 or 512 mid-power LED chips mounted on aluminum core printed circuit boards. LED light engines are replaceable. ELECTRICAL V LED power supply, power factor is > V dimmable, standard. Power supplies are mounted in direct contact with steel housing for cooler operation and longer life. Drive current is 1500mA for 4 ft. fixures (43W, 86W units) and for 8 ft. fixtures (86W, 170W). Drive current is 2100mA for 4 ft 60W and 8 ft. 125W fixtures. One power supply is used in 43W and 60W units. Two power supplies are used in the 86W and 120W units. Four power supplies are used in the 170W unit. Power supplies can be accessed from below and are replaceable. The CHLED series is designed to operate in temperatures of -40 F (-40 C) to 113 F (40 C). ACCESS / WIRING Tooless access to wireway channel. Wireway cover/led tray snaps onto the housing and can be removed wthout tools. LED tray can be secured to housing wih screws (optional). Wireway cover/led tray is tethered to the housing for easier installation and maintenance. Internal plug-in wiring harness. MOUNTING Suitable for surface, pendant, stem, or chain mounting, individualy or in continuous rows. Use accessory CHJ joiner to connect fixtures in continuous rows. LISTINGS C-UL-US listed, damp location. DesignLights Consortium qualified. WARRANTY 5 year limited warranty CHLED LED Striplight Configuration SERIES LENGTH WATTAGE* COLOR TEMPERATURE VOLTAGE OPTIONS ACCESSORIES CHLED 4 = 4' 8 = 8' 4' Units 43 = 43W 60 = 60W 86 = 86W 8' Units 86 = 86W 120 = 120W 170 = 170W 35 = 3500 K 41 = 4100 K 50 = 5000 K * Nominal. See technical specifications for actual input power. U1 = Universal V 347 = 347V 480 = 480V ELS = Emergency Backup, 900lm 6 Cord and Plug CPT(x) 1 = 120V 2 = 277V 3 = 208V 4 = 240V 5 = 480V CP3 = Cord & Plug-120V Straight Blade 5-15P FL4 = 3/8, 6 flex with two #18, one ground and two connectors FL5 = 3/8, 6 flex with three #18, one ground and two connectors C = Single white canopy (for use with pendant mount) CA24 = Chain Hanger Assembly-(2) 18 chains, (2) V hooks, (2) S hooks for total drop 24 CHJ = Housing Joiner (to connect long runs) CS24 = S Hook (4) Chain Hanger Assembly (24 total drop) PM(x) = Pendant Mount, white stem-specify length in inches (24, 36, 48, 60, 72) SN = Snapper Brackets TB4 = T-Bar grid mounting clip WG240 = 48 wire guard (order 2 for 8' units)) Dimensions 2 1/4" 4 1/4" 48" / 96" CHLED Performance K CCT Model Light Output* Input Power Efficacy CHLED44341U1 5,042 lumens watts 116 lpw CHLED46041U1 6,574 lumens watts 105 lpw CHLED48641U1 10,240 lumens watts 121 lpw CHLED88641U1 9,836 lumens watts 114 lpw CHLED812041U1 13,148 lumens watts 105 lpw CHLED817041U1 20,480 lumens watts 119 lpw *Delivered lumens **Consult a lighting engineer to meet specific requirements. LM79 photometric testing pending. Performance based on calculated data RoHS COMPLIANT LED LED Simkar 700 Ramona Avenue Philadelphia, Pennsylvania CHLED

62 Date: Type: Firm Name: Project: ew Profile Powercore Ultra-low-profile LED under-cabinet fixture for task and accent lighting Ordering Information Voltage 100 VAC including Mounting Clips and End-to- End Connector 120 VAC* including Mounting Clips and End-to- End Connector VAC including Mounting Clips and End-to- End Connector VAC including Mounting Clips, Leader Cable, and Terminator * energy star Color Temperature 3000 K 4000 K 2700 K 3000 K 4000 K 3000 K 4000 K 3000 K 4000 K ew Profile Powercore Fixtures 9.25 in (235 mm) in (489 mm) in (997 mm) Housing Color Item Number Philips 12NC Item Number Philips 12NC Item Number Philips 12NC White Black Gray White Black Gray White Black Grey White Black Gray White Black Gray White Black Gray White Black Gray White Black Gray White Black Gray Use Item Number when ordering in North America. E For more information on how to buy Philips Color Kinetics LED lighting systems, visit howtobuy/

63 ew Profile Powercore Accessories Item Size Housing Color Item Number Philips 12NC For permanent installations outside of North America. Leader Cable and Terminator, 100 / VAC 10 ft (3 m) White Black For permanent installations in North America. Permanent Wiring Compartment and Terminator, 120 VAC x 1.75 x 3.5 in (29 x 45 x 89 mm) (Height x Width x Depth) White Black Gray / Black* For portable installations in North America. Switched Portable Leader Cable and Terminator, 120 VAC 10 ft (3 m) White Black Gray / Black* For permanent installations in North America. Switched Permanent Wiring Compartment and Terminators, 120 VAC.875 x 2 x 4.25 in (22 x 51 x 108 mm) (Height x Width x Depth) White Black Gray End-to-End Connectors connect fixtures in a solid linear run. End-to-End Connector, Quantity in (22 mm) White Black Gray in (152 mm) White Black Jumper Cable, 100 / VAC 12 in (305 mm) 18 in (457 mm) White Black White Black Jumper Cables add extra space between fixtures in a series. 5 ft (1.5 m) 6 in (152 mm) White Black White Black Jumper Cable, 120 VAC 12 in (305 mm) 18 in (457 mm) White Black White Black ft (1.5 m) White Black Y Jumper Cables split a single run of fixtures into two separate runs. Y Jumper Cable and Terminator, 100 / VAC Y Jumper Cable and Terminator, 120 VAC 16.5 in (419 mm) 16.5 in (419 mm) White Black White Black Optional Mounting Track ensures straight runs of fixtures. Philips Color Kinetics 3 Burlington Woods Drive Burlington, Massachusetts USA Tel Tel Fax Mounting Track 9 in (229 mm) 19 in (483 mm) 39 in (991 mm) * Housings are Gray, Cables are Black Requires Jumper Cable for fixture connection White Black Gray White Black Gray White Black Gray Use Item Number when ordering in North America. Copyright 2014 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iw Reach, ew Reach, ew Fuse, DIMand, EssentialWhite, ew, icolor, icolor Cove, IntelliWhite, iw, iplayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may without notice. DAS R

64 LOW VOLTAGE PENDANTS Mini Echo Pendant DESCRIPTION Translucent cylinder over a white case glass cylinder, highlighted with three metal details. Includes low voltage, 50 watt halogen bi pin lamp or 8 watt replaceable 500 lumen 80 CRI 3000K LED SORAAÂ module and six feet of field cuttable suspension cable. Works with SORAA. INSTALLATION Socket terminates with FreeJack male connector, which may be installed into a system connector. Elements ordered with a system prefix include a connector for that system. ACCESSORIES & OPTICAL CONTROLS SORAA LED Bi Pin Replacement Pendant Module, Swag Hook WEIGHT 1.3lb / 0.59kg ± smoke amber aquamarine clear havana brown smoke steel blue ORDERING INFORMATION 700 SYSTEM ECP COLOR FINISH LAMP FJ FREEJACK MP MONOPOINT MO MONORAIL MO2 TWO CIRCUIT MONORAIL A Q C B S U AMBER AQUAMARINE CLEAR HAVANA BROWN SMOKE STEEL BLUE Z ANTIQUE BRONZE C CHROME S SATIN NICKEL 12 VOLT HALOGEN LEDS VOLT LED 80 CRI 3000K VOLT HALOGEN Note: MP includes 4" Round Flush Canopy.Note: MP includes 4 Round Flush Canopy. When installing LED option on MO2 only magnetic transformers may be used. 700 ECP FIXTURE TYPE: JOB NAME: 7400 Linder Avenue Skokie, Illinois T F NOTES: Tech Lighting, L.L.C Tech Lighting, L.L.C. All Rights Reserved. The "Tech Lighting" graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification.

RSW Series RSW LED Street Luminaire Small

RSW Series RSW LED Street Luminaire Small RSW Series RSW LED Street Luminaire Small Product Description The Cree RSW Series, utilizing WaveMax Technology, will transform the way utilities and municipalities light their residential streets. With

More information

304 Series LED Recessed Canopy Luminaire

304 Series LED Recessed Canopy Luminaire 304 Series LED Recessed Canopy Luminaire Product Description Luminaire housing is constructed from rugged die cast aluminum components (RS Mount) or die cast and extruded aluminum components (RD Mount).

More information

XSP High Output Series XSP2 High Output LED Street/Area Luminaire Double Module

XSP High Output Series XSP2 High Output LED Street/Area Luminaire Double Module XSP High Output Series XSP High Output LED Street/Area Luminaire Double Module Product Description Designed from the ground up as a totally optimized LED street and area lighting system, the XSP High Output

More information

XSP Series XSP2 LED Street/Area Luminaire Double Module Version C

XSP Series XSP2 LED Street/Area Luminaire Double Module Version C XSP Series XSP LED Street/Area Luminaire Double Module Version C Product Description Designed from the ground up as a totally optimized LED street and area lighting system, the XSP Series delivers incredible

More information

Cree Edge Series LED Area Luminaire Round

Cree Edge Series LED Area Luminaire Round Cree Edge Series LED Area Luminaire Round Product Description The Cree Edge Series has a slim, low profile design. Its rugged cast aluminum housing minimizes wind load requirements and features an integral,

More information

XSP Series XSPR LED Street/Area Luminaire Version A

XSP Series XSPR LED Street/Area Luminaire Version A XSP Series Product Description In addition to a low initial cost, the XSPR LED Street luminaire maintains the familiar look of the traditional cobrahead design and delivers substantial energy savings while

More information

LIGHT FANTASTIC II, III

LIGHT FANTASTIC II, III LIGHT FANTASTIC II, III Use & Care LFCIII, LFCIIID LFCII & LFCII-D LFIII & LFII UNIT &CHAIR MOUNT LFTIII, LFTIIID LFTII & LFTII-D LFCBIII, LFWIII LFCBII & LFWII TABLE OF CONTENTS INTRODUCTION... 3 Definitions

More information

LED Flat Panel Luminaires

LED Flat Panel Luminaires LED Flat Panel Luminaires Great Features/Benefits TCP s LED Flat Panel Luminaire features a slim, low-profile design with full panel diffusion and superior uniformity. It offers a cost effective solution

More information

304 Series LED Parking Structure Luminaire

304 Series LED Parking Structure Luminaire 304 Series LED Parking Structure Luminaire Product Description Slim, low profile design. Luminaire is constructed from rugged die cast and extruded aluminum components. LED driver is mounted in a sealed

More information

LED Flat Panel Luminaires

LED Flat Panel Luminaires LED Flat Panel Luminaires 0-347V Great Features/Benefits TCP s LED Flat Panel Luminaire features a slim, low-profile design with full panel diffusion and superior uniformity. It offers a cost effective

More information

19.0" (482mm) Performance Summary 3.1" (79mm) NanoOptic Precision Delivery Grid optic Receptacle location (ordered as an option)

19.0 (482mm) Performance Summary 3.1 (79mm) NanoOptic Precision Delivery Grid optic Receptacle location (ordered as an option) (69mm) 19.0" (48mm) OSQ Series 3" (79mm) OSQ LED Area/Flood Luminaire Medium Product Description NEMA Photocell Receptacle location (ordered as an option) DA Mount The OSQ Area/Flood luminaire blends extreme

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

Spirit 2000 Series Installation Instructions

Spirit 2000 Series Installation Instructions Model: SCT20 Catalog: 2100, 2105 PMU Mounted Catalog 2222, 2322 Cabinet Mounted Model: SDW-D Catalog: 2600 Wall Mounted Model: SDC-D Catalog: 2610 Cabinet Mounted Spirit 2000 Series Installation Instructions

More information

LEDway Series LEDway High Output Street Light Single Module

LEDway Series LEDway High Output Street Light Single Module LEDway Series LEDway High Output Street Light Single Module Product Description LEDway High Output Streetlight series for roadway lighting expands the application range replacing from 70W to 400W HPS.

More information

Midmark Track Light Installation

Midmark Track Light Installation Midmark Track Light Installation [Full size ceiling template is available: 003-1287-00] Applies to Models: 153910 (-002) 153656 (-001) Language of origin: English Physical Requirements warning Equipment

More information

LED Flat Panel Luminaires

LED Flat Panel Luminaires LED Flat Panel Luminaires Great Features/Benefits TCP s LED Flat Panel Luminaires feature a slim, low-profile design with full panel diffusion and superior uniformity. These DLC Premium listed flat panels

More information

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire Catalog # : Project : Prepared By : Date : Scottsdale Vertex - SCV The Scottsdale Vertex is the most feature-rich canopy fixture in the marketplace. Innovations such as combined optical distributions,

More information

Track Light with Monitor Installation Guide

Track Light with Monitor Installation Guide Track Light with Monitor Installation Guide This installation requires at least two service technicians. Track with light and monitor weight (max.) is 157 Lbs. (71 kgs). Applies to Models: 1531017 (-000

More information

Asepsis 21 Delivery Unit

Asepsis 21 Delivery Unit INSTALLATION INSTRUCTIONS for the Console Mounted TM Asepsis 21 Delivery Unit SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 3. WATER SUPPLY REQUIREMENTS... 1 4.

More information

Cree Edge Series LED Area/Flood Luminaire

Cree Edge Series LED Area/Flood Luminaire Cree Edge Series LED Area/Flood Luminaire Product Description The Cree Edge Series has a slim, low profile design. Its rugged cast aluminum housing minimizes wind load requirements and features an integral,

More information

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire Catalog # : Project : Prepared By : Date : Scottsdale Vertex - SCV The Scottsdale Vertex is the most feature-rich canopy fixture in the marketplace. Innovations such as combined optical distributions,

More information

LAD6 6 LED Architectural Downlight

LAD6 6 LED Architectural Downlight Catalog # : Project : Prepared By : Date : LAD6 6 inch LED new construction downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even illumination

More information

304 Series LED Interior Recessed Luminaire

304 Series LED Interior Recessed Luminaire 304 Series LED Interior Recessed Luminaire Product Description High performance energy efficient LED down light, designed for use in drop ceilings with 20-24" (508-610mm) on center building construction.

More information

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE Project Type Notes 5 1/32" PERFORMANCE PER LINEAR FOOT AT 4000K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY 750 lm/ft 7.5 W/ft 97 lm/w * Based on a 4 foot luminaire using one driver Please consult factory

More information

D3 INSTALLATION GUIDE

D3 INSTALLATION GUIDE D3 INSTALLATION GUIDE Supported Models D3-FXRD D3-FXSQ D3-ADRD D3-ADSQ D3-WWRD D3-WWSQ D3 INSTALLATION GUIDE 770-000028-0X r09 PAGE 1 ! WARNING! Shock Hazard. May result in serious injury or death. Turn

More information

LAD8 8 LED Architectural Downlight

LAD8 8 LED Architectural Downlight Catalog # : Project : Prepared By : Date : LAD8 8 inch LED new construction downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even illumination

More information

Project Name. 23-3/4 (603.3mm)

Project Name. 23-3/4 (603.3mm) LUCEN 2x4 Project Name Date Type ARCHITECTURAL RECESSED LUMINAIRE 3-3/4 (95.3mm) 48 (1224mm) 23-3/4 (603.3mm) Pre-painted formed 22 gauge cold rolled steel housing Highly reflective die-formed white painted

More information

AIM LED LIGHT (ceiling mount)

AIM LED LIGHT (ceiling mount) AIM LED LIGHT (ceiling mount) Installation Manual AIM LED LIGHT (ceiling mount) INTRODUCTION Lights in the AIM Series are designed to give the professional health care market superior performance, reliability

More information

LAD4 4 LED Architectural Downlight

LAD4 4 LED Architectural Downlight Catalog # : Project : Prepared By : Date : LAD4 4 inch LED new construction downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even illumination

More information

Installation, Operation & Maintenance

Installation, Operation & Maintenance OTO Installation, Operation & Maintenance 1 Installation, Operation & Maintenance OTO Curved Slot Swirl Diffusers Last Revision 2016-08 H V A C TM Architecture, Comfort, Efficiency OTO Installation, Operation

More information

axcs Magellan CMU Installation, Operation and Care Manual

axcs Magellan CMU Installation, Operation and Care Manual axcs Magellan CMU 123456789012 123456789012 123456789012 123456789012 Installation, Operation and Care Manual Table of Contents Section I Introduction Introduction... 2 Specifications... 3 Basic Components...

More information

PET UNIT DOSE CABINET

PET UNIT DOSE CABINET PET UNIT DOSE CABINET INSTALLATION MANUAL 244-200 244-205 FN: 08-134 Rev A 11/17 Pet Unit Dose Cabinet This manual covers operation procedures for the following products: 244-200 Cabinet, PET, Unit Dose

More information

Remodeler. Complete product = Frame-in kit + Light engine + Trim Order each separately. E ELV dimming 1 120V VA Version A 2 Z V

Remodeler. Complete product = Frame-in kit + Light engine + Trim Order each separately. E ELV dimming 1 120V VA Version A 2 Z V New construction Downlighting Project: Location: Cat.No: LyteCaster Remodeler Type: Lamps: Notes: Qty: Round downlight Philips Lightolier LyteCaster LED Downlights are ideal general purpose downlighting

More information

axcs Operatory Light (Track, Ceiling, Wall and Cabinet Mount) Installation, Operation and Care Manual

axcs Operatory Light (Track, Ceiling, Wall and Cabinet Mount) Installation, Operation and Care Manual acs Operatory Light (Track, Ceiling, Wall and Cabinet Mount) Installation, Operation and Care Manual Table of Contents Section I Introduction Features/Benefits... 2 Specifications...2 Dimension Diagrams...

More information

ECO EXT (DIMMABLE)

ECO EXT (DIMMABLE) Not all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. ECO EXT (DIMMABLE) www.trulygreensolutions.com

More information

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE Project Name Date Type ARCHITECTURAL RECESSED LUMINAIRE 3-3/4 (95.3mm) 23-3/4 (603.3mm) 23-3/4 (603.3mm) Pre-painted formed 22 gauge cold rolled steel housing Highly reflective die-formed white painted

More information

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS ALL700/ALL700-CM INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power

More information

ALL W INSTALLATION INSTRUCTIONS

ALL W INSTALLATION INSTRUCTIONS ALL1000-3300W INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source

More information

Loose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:

Loose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models: VetPro 5000 Wall / Cabinet Mount Installation warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. Applies to Models: 8001-001 8001-002 8001-005 8001-006 Loose Components

More information

TRUET5 EXT (DIMMABLE)

TRUET5 EXT (DIMMABLE) t all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. TRUET5 EXT (DIMMABLE) www.trulygreensolutions.com

More information

FINELITE 10 Year LED Warranty

FINELITE 10 Year LED Warranty 10 Industry Best Year LED Warranty 20I2 Refer to spec page for details High Performance Aperture (HP-4) - Date Project Type Comments Flush Diffuser Flat Diffuser with Regressed DESCRIPTION High Performance

More information

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately New Downlighting Project: Location: Cat.No: LyteCaster Remodeler Type: Lamps: Notes: Qty: Round downlight Philips Lightolier LyteCaster LED Downlights are ideal general purpose downlighting solution, providing

More information

2 LED Designer Series

2 LED Designer Series LED Designer Series When appearance is most important, TCP s LED Designer Series turns any location into something truly exceptional. Limitless options for the following applications: Offices Restaurants

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

LEN Series 2x2 / 2x4 LED

LEN Series 2x2 / 2x4 LED FEATURES & SPECIFICATIONS Intended Use The LEN offers the look and feel of a fluorescent luminaire - subtle soft direct elements, interest and depth across the ceiling plane - with a contemporary look

More information

BEAM SPREAD NR = Narrow (36 degree) WD = Wide (56 degree) WW 2 = Wall Wash. REFLECTOR FINISH SD = Semi- Diffused

BEAM SPREAD NR = Narrow (36 degree) WD = Wide (56 degree) WW 2 = Wall Wash. REFLECTOR FINISH SD = Semi- Diffused Lumination LED Luminaires Retrofit Commercial Downlight LED LRC Series Product Description: Convert any commercial or industrial downlight to LED with the new Lumination LRC Series retrofit LED downlight.

More information

LCD4 4 LED Commercial Downlight

LCD4 4 LED Commercial Downlight Catalog # : Project : Prepared By : Date : LCD4 4 inch LED new construction downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even illumination

More information

LCD6 6 LED Commercial Downlight

LCD6 6 LED Commercial Downlight Catalog # : Project : Prepared By : Date : LCD6 6 inch LED new construction downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even illumination

More information

LCD8 8 LED Commercial Downlight

LCD8 8 LED Commercial Downlight Catalog # : Project : Prepared By : Date : LCD8 8 inch LED new construction downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even illumination

More information

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed. Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2) Table of Contents

More information

RETRACTABLE CEILING COLUMN

RETRACTABLE CEILING COLUMN RETRACTABLE CEILING COLUMN Installation Manual RETRACTABLE CEILING COLUMN INTRODUCTION Location, sequence of services and orientation of Surgical Ceiling Columns are specified on the building plans. Be

More information

XSP Series - IP66. XSP2 TM LED Street /Area Light Double Module - Version B. Product Description. Performance Summary. Accessories

XSP Series - IP66. XSP2 TM LED Street /Area Light Double Module - Version B. Product Description. Performance Summary. Accessories XSP Series - IP66 XSP2 TM LED Street /Area Light Double Module - Version B Product Description Designed from the ground up as a totally optimized LED street and area lighting system, the XSP Series delivers

More information

AIM LED LIGHT (wall mount)

AIM LED LIGHT (wall mount) AIM LED LIGHT (wall mount) Installation Manual AIM LED LIGHT (wall mount) INTRODUCTION Lights in the AIM Series are designed to give the professional health care market superior performance, reliability

More information

Installation Instructions Table of Contents

Installation Instructions Table of Contents Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft

More information

OSQ Series OSQ LED Area/Flood Luminaire Large

OSQ Series OSQ LED Area/Flood Luminaire Large OSQ Series OSQ LED Area/Flood Luminaire Large Product Description DA Mount The OSQ Area/Flood luminaire blends extreme optical control, advanced thermal management and modern, clean aesthetics. Built to

More information

www.greenelectricalsupply.com LED Technical Data High efficiency s. Use anywhere you need exceptional light distribution for mounting heights up to 40 feet. LIMITLESS OPTIONS for the following applications:

More information

Project Name. 24 (609.6mm) 24 (609.6mm)

Project Name. 24 (609.6mm) 24 (609.6mm) Project Name Date Type ARCHITECTURAL RECESSED LUMINAIRE 24 (609.6mm) 24 (609.6mm) 3 (76.2mm) Formed 20 gauge cold rolled steel housing Highly reflective die-formed white painted reflector Wiring access

More information

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 16 1 AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

KIT-XSP-AP60-34-G0 Fitter kit to mount to 34mm tenon 303mm XSP B 02 2LG A 30K + 24 SV DIM 01. Insulation Class CCT. Voltage

KIT-XSP-AP60-34-G0 Fitter kit to mount to 34mm tenon 303mm XSP B 02 2LG A 30K + 24 SV DIM 01. Insulation Class CCT. Voltage XSP Series - IP66 XSP1 TM LED Street /Area Light Single Module - Version B Product Description Designed from the ground up as a totally optimized LED street and area lighting system, the XSP Series delivers

More information

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately New construction Downlighting Project: Location: Cat.No: LyteCaster Remodeler Type: Lamps: Notes: Qty: Round adjustable Philips Lightolier LyteCaster LED Adjustable Downlight is a low cost solution for

More information

Installation Manual 354 / 355 Combination Lighting System

Installation Manual 354 / 355 Combination Lighting System Installation Manual 354 / 355 Combination Lighting System MA551601 180 Height of Lighthead Assembly Adjustable from 50.0 in. (127.0 cm) to 74.0 in. (188 cm) above floor Based on 8' units with 8' Ceiling

More information

Project Name. 24 (609.6mm)

Project Name. 24 (609.6mm) 2x4 Project Name Date Type ARCHITECTURAL RECESSED LUMINAIRE 48 (1,219.2mm) 3 (76.2mm) 24 (609.6mm) Formed 20 gauge cold rolled steel housing Highly reflective die-formed white painted reflector Wiring

More information

FINELITE. 10 Year LED Warranty. High Performance Recessed (HPR LED) 2x2, Standard Output (S), Boosted Standard Output (B)

FINELITE. 10 Year LED Warranty. High Performance Recessed (HPR LED) 2x2, Standard Output (S), Boosted Standard Output (B) 10 Industry Best Year LED Warranty Refer to spec page for details Date Project Type Comments Refer to page 2 for all door styles DESCRIPTION HPR LED is a highly efficient recessed luminaire delivering

More information

style with efficiency

style with efficiency Architectural style with efficiency and visual comfort DUALED PHILIPS DAY-BRITE / PHILIPS CFI DUALED RECESSED LED 2x2 WITH SPACEWISE TECHNOLOGY OPTION DuaLED is a highly efficient, visually comfortable,

More information

ALL700RM-230V INSTALLATION INSTRUCTIONS

ALL700RM-230V INSTALLATION INSTRUCTIONS ALL700RM-230V INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

OSQ High Output LED Area/Flood Luminaire featuring Cree TrueWhite Technology. Product Specifications. Electrical Data*

OSQ High Output LED Area/Flood Luminaire featuring Cree TrueWhite Technology. Product Specifications. Electrical Data* OSQ Series Product Description DA Mount The OSQ High Output Area/Flood luminaire blends extreme optical control, advanced thermal management and modern, clean aesthetics. Built to last, the housing is

More information

LAD8R - Remodel 8 LED Architectural Downlight

LAD8R - Remodel 8 LED Architectural Downlight Catalog # : Project : Prepared By : Date : LAD8R - Remodel 8 inch Remodel LED downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even

More information

OSQ LED Area/Flood Luminaire Medium

OSQ LED Area/Flood Luminaire Medium OSQ Series OSQ LED Area/Flood Luminaire Medium Product Description The OSQ Area/Flood luminaire blends extreme optical control, advanced thermal management and modern, clean aesthetics. Built to last,

More information

Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

Finelite, Inc Whipple Road Union City, CA / Fax: 510 / 10 Industry Best Year LED Warranty Date Project Type Comments Flush Diffuser Flat Diffuser with Regressed DESCRIPTION High Performance 2" Aperture (HP-2 R) is a patented, linear recessed LED luminaire

More information

Installation and Service Manual

Installation and Service Manual RESIDENTIAL PLATFORM LIFTS RPL400 / RPL600 Installation and Service Manual WARNING! STRICT ADHERENCE TO THESE INSTALLATION INSTRUCTIONS IS REQUIRED to promote the safety of those installing this product,

More information

CONVERJ CJ24 2x4 Architectural Recessed

CONVERJ CJ24 2x4 Architectural Recessed Project Name Date Type CONVERJ CJ24 2x4 Architectural Recessed 3-1/2" (88.9mm) 24" (609.6mm) Key Features Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector

More information

Cree Square LED High Output Series

Cree Square LED High Output Series Cree Square LED High Output Series MINI Product Description Conceived with an essential design, this luminaire has a simple square shape which practically integrates in all environments; also its square

More information

INSTALLATION GUIDE INSTALLATION GUIDE

INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE Technical Specifications READ AND SAVE THESE INSTRUCTIONS Check the fan label to make sure it is the correct voltage. Operating voltage Diameter Weight Operating frequency

More information

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate (Refer to qualified

More information

XSP High Output Series

XSP High Output Series XSP High Output Series XSPR TM High Output LED Street/Area Luminaire Product Description In addition to a low initial cost, the XSPR High Output LED Street Light maintains the familiar look of the traditional

More information

LAD6R - Remodel 6 LED Architectural Downlight

LAD6R - Remodel 6 LED Architectural Downlight Catalog # : Project : Prepared By : Date : LAD6R - Remodel 6 inch LED remodel downlight delivers superior performance and energy efficiency. Designed to use anodized aluminum reflectors delivering even

More information

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Installation Instructions Capacity 10,000 lbs. (100 Series Lift) Installation Instructions Capacity 10,000 lbs. (100 Series Lift) IMPORTANT Reference ANSI/ALI ALIS, Safety Requirements for Installation and Service of Automotive Lifts before installing lift. OPERATING

More information

Operating Instructions

Operating Instructions DuroSite & SafeSite Area Light with Adapters Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury,

More information

Chain/Belt Drive Models PRE-INSTALLATION CONSIDERATIONS

Chain/Belt Drive Models PRE-INSTALLATION CONSIDERATIONS 38968503545. 08/2017 ASSEMBLY/INSTALLATION Chain/Belt Drive Models PRE-INSTALLATION CONSIDERATIONS This opener includes parts and supplies needed for installation in most garages and on most garage doors.

More information

Catalog # Project. Comments. Prepared by. 6.4" [163 mm] Lumen Package Nominal per 4 section

Catalog # Project. Comments. Prepared by. 6.4 [163 mm] Lumen Package Nominal per 4 section DESCRIPTION The RZL is a suspended linear direct and semi-direct LED continuous row solution for new and retrofit construction. Designed for larger open ceiling environments, the RZL offers advanced LED

More information

Plasma Display Electric Ceiling Lifts

Plasma Display Electric Ceiling Lifts I N S T R U C T I O N M A N U A L The Plasma Display Electric Ceiling Lift is designed for plasma displays requiring an extended drop (18 to 42 inches) from their hidden location. The lift is designed

More information

MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012

MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1. LISTING REQUIREMENTS MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL) as defined by the U.S.

More information

IG SERIES LED PARKING STRUCTURE LUMINAIRE. Makes You Want to Spend More Time in the Garage.

IG SERIES LED PARKING STRUCTURE LUMINAIRE. Makes You Want to Spend More Time in the Garage. IG SERIES LED PARKING STRUCTURE LUMINAIRE Makes You Want to Spend More Time in the Garage. IG Series Parking Garage Luminaire / Benefits IG Series Parking Garage Luminaire / Benefits LED Parking Structure

More information

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications PRODUCT FEATURES: 6" sealed, recessed downlight with regressed or flush lens trim Conducted emissions controlled as per MIL-STD-461F Delivered lumens: 794-5,543 lm 1% Dimming via 0-10V, DALI or EcoSystem

More information

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100 Product Information Project Name Catalog Number QCF Type Date SPECIFICATIONS Features Upgrade to modern architectural aesthetics providing controlled uniform light distribution. Improves facial recognition

More information

LED DockLight. Sustainable lighting with powerful output. UL listed for wet locations. Standard 5 year warranty

LED DockLight. Sustainable lighting with powerful output. UL listed for wet locations. Standard 5 year warranty Patent # USD0587833 Sustainable lighting with powerful output Industrial luminaire with 15 watt power consumption Rated life of 50,000 hrs to 70% lumen maintenance Highly impact resistant; LED technology

More information

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED Product Information Project Name Catalog Number QCF Type Date SPECIFICATIONS Features Upgrade to modern architectural aesthetics providing controlled uniform light distribution. Improves facial recognition

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us: LED Area Light scratch that. This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechelectronics.com sales@altechelectronics.com

More information

OSQ Series LED Area/Flood Luminaire Medium

OSQ Series LED Area/Flood Luminaire Medium 10.6" (69mm) 19.0" (48mm) OSQ Series LED rea/flood Luminaire Medium Product Description 3" (79mm) NEM Photocell (R Option Only) D Mount The OSQ rea/flood luminaire blends extreme optical control, advanced

More information

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices. 5 YEAR WARRANTY 5 YEAR WARRANTY COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS E354088 LISTED AC E354088 58VDC E354088 E354088 5 5 YEAR WARRANTY 5 YEAR WARRANTY E354088 Caution: Observe precautions for

More information

INSTALLATION GUIDE INSTALLATION GUIDE

INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE Technical Specifications READ AND SAVE THESE INSTRUCTIONS Check the fan label to make sure it is the correct voltage. Operating voltage Diameter Weight Operating frequency

More information

CONVERJ CJ22 2x2 Architectural Recessed

CONVERJ CJ22 2x2 Architectural Recessed Project Name Date Type CONVERJ CJ22 2x2 Architectural Recessed 3-1/2" (88.9mm) 24" (609.6mm) Key Features Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector.

More information

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23 VIPP521-526 LAMPS 1 CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP 10-15 VIPP522 WALL LAMP 16-23 VIPP524 WALL SPOT 24-31 VIPP525 FLOOR LAMP 32-41 VIPP526

More information

INSTALLATION GUIDE INSTALLATION GUIDE

INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE CONTACT US By selecting a Haiku fan, you ve chosen quality design, heightened comfort and effortless conservation. Use this guide to safely install your fan. Please

More information

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by: Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All

More information

Limited Warranty : 10 years on luminaire / 10 years on Colorfast DeltaGuard finish 6.1" (155mm) Color Options. Drive Current

Limited Warranty : 10 years on luminaire / 10 years on Colorfast DeltaGuard finish 6.1 (155mm) Color Options. Drive Current CAN-304-PS-RD 304 Series Canopy Luminaire Petroleum Symmetric Recessed Mount for Double Skin Canopies Product Description Slim, low profile design. Luminaire is constructed from rugged die-cast and extruded

More information

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Language of origin: English Equipment Alert Do not remove wraps or packaging from the delivery flex arm assembly until it is

More information

CONVERJ CJ14 1x4 Architectural Recessed

CONVERJ CJ14 1x4 Architectural Recessed Project Name Date Type CONVERJ CJ14 1x4 Architectural Recessed 3-1/2" (88.9mm) 12" (304.8mm) Key Features Formed 20 gauge cold rolled steel housing. Highly reflective die-formed white painted reflector

More information