ELECTRO-MECH SCOREBOARD CO.

Size: px
Start display at page:

Download "ELECTRO-MECH SCOREBOARD CO."

Transcription

1 LCTRO-MCH SCORBOARD CO BASBALL SCORBOARD OWNR S HANDBOOK Thank you for choosing an lectro-mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give many years of reliable service. Rev. 6 Revised: 04/27/2006

2 1260 Page 2 TABL O CONTNTS SCORBOARD SPCIICATIONS... 3 SCORBOARD INSTALLATION... 4 MCHANICAL INSTALLATION...4 Post Installation...4 Mounting The Scoreboard...8 MOUNTING HARDWAR...9 Mounting The Optional Side Sponsor Panel...11 Mounting The Optional Top Sponsor Panel...11 LCTRICAL INSTALLATION...12 Ground Connection...12 Power Connections...13 ScoreLink Control Cable Installation...14 Control Console Connections...16 Control Console Safety Warning...16 SCORBOARD OPRATION SCORBOARD STARTUP...17 GAM TIM OPRATION...17 SCORBOARD SHUTDOWN...18 SRVICING TH SCORBOARD COMPONNT RPLACMNT...19 LD Digits And Indicators Replacement...19 LD Driver Module Replacement...22 LD Power Supply Module Replacement...24 LD Power Interface Board Replacement...25 WARRANTY... 26

3 1260 Page 3 SCORBOARD SPCIICATIONS GNRAL: This TL listed scoreboard includes the scoreboard cabinet, mounting hardware, control console, 10 ft. extension cable, and junction box. DIMNSIONS: 12 L x 8 H x 6 D (1260 with a side sponsor panel measures 20 L x 8 H x 6 D, 1260 with two side sponsor panels measures 28 L x 8 H x 6 D) WIGHT: 285 lbs (1260 with a side sponsor panel weighs 420 lbs, 1260 with two side sponsor panels weighs 555 lbs.) SCORBOARD CONSTRUCTION: The outer frame is made from extruded aluminum. Internal structural parts may be extruded aluminum or formed from aluminum sheet. The face and back are made from aluminum sheet. The face and masks are finished with enamel paint. Black is the standard color. The captions are white exterior grade vinyl. DISPLAY: The 1260 baseball scoreboard displays HOM and GUST scores to 99, INNINGS (INNING) to 19, BALLS (BALL), STRIKS (STRIK), OUTS (OUT), HIT (H), and RROR (). DIGITS AND INDICATORS: Red light emitting diodes mounted on printed circuit boards form the digits and indicators. The score digits are 24 tall. All other digits are 18 tall. Circular clusters of light emitting diodes form the 4 diameter HIT and RROR indicators. POWR RQUIRMNTS: Scoreboard VAC, 1.3 A, 60 Hz Control Console VAC, 0.5 A, 60 Hz SCORBOARD LCTRONICS: 100% solid state fully enclosed. CONTROL CONSOL: The control console features a microprocessor, 15 key sealed membrane keypad, and an attached 6 foot power cord. The console housing consists of ABS plastic base and top pieces with a steel back plate. CONTROL CABL: The cable has two 22 AWG stranded copper conductors with semi-rigid PVC insulation. It also has a braided shield and a foil shield. The polyethylene jacket is rated at 300 volts. The cable is direct burial rated and measures approximately ¼ in diameter. This item is sold separately from the scoreboard. JUNCTION BOX AND XTNSION CABL: A 4 ¼ x 2 ¼ x 2 junction box with a ¼ stereo jack mounted on the face plate is attached to the control cable at the point of operation. A 10 ft. extension cable connects the control console to the junction box. SCORLINK 300 R MODM SYSTM: This accessory can be used in place of control cable and junction box for this scoreboard without internal modifications to the scoreboard or the control console. Refer to the SCORLINK 300 R MODM SYSTM OWNR S HANDBOOK for more information. WARRANTY: ive year limited warranty.

4 1260 Page 4 SCORBOARD INSTALLATION This part of the manual describes the mechanical and electrical installation of the scoreboard. One of the items listed below must be purchased in order to complete the installation: Control cable (length dependent upon installation site layout) ScoreLink 300 R Modem System Items not provided by lectro-mech Scoreboard Company that are necessary for installation: Two posts (Additional posts are needed if optional side sponsor panels are purchased.) Power cable to connect the scoreboard to the power source Grounding hardware A grounded NMA 5-15R 120 VAC receptacle for the control console at the scorekeeper s table. Items not provided that are recommended by lectro-mech Scoreboard Company for installation: A weatherproof power disconnect at the scoreboard lectro-mech Scoreboard Company performs installations in some areas. In other areas, we can help you contact an independent installer. In areas in which installation service is not available from lectro-mech Scoreboard Company, we will make every effort to answer your installation questions. Qualified personnel should perform the scoreboard installation. Consult national and local codes before installation. MCHANICAL INSTALLATION The mechanical installation includes installing the posts and mounting the scoreboard and the optional sponsor panels (if purchased) to the posts. Post Installation The scoreboard mounts on two posts. An additional post will be required for each optional side sponsor panel, if purchased. Typically installers will use steel pipes or I- beams. In order to reduce the glare from the sun on the front of the scoreboard, position the posts so that the front of the scoreboard is angled away from the afternoon sun, if possible. The mounting hardware will accommodate posts up to 7 inches outer diameter. Sink the posts in reinforced concrete footings. igure 1 shows the spacing of the posts for a 1260 scoreboard. The specifications for the posts and concrete footings are dependent upon the expected local wind and soil conditions, the height of the scoreboard from the ground, and the local building codes. lectro-mech Scoreboard Company assumes no responsibility for the installation of scoreboards by others.

5 1260 Page 5 12' 8' 8' WATHRPROO CONVNINC RCPTACL POWR CABL IN 3/4" CONDUIT POWR DISCONNCT #6 BAR COPPR GROUND WIR 5/8" BRASS TAR DROP CONNCTOR 5/8" X 8' COPPR CLAD GROUND ROD CONTROL CABL IN 3/4" CONDUIT TO CONTROL LOCATION TO POWR SOURC 10' igure Post Spacing igure 2 shows the spacing of the posts for a 1260 scoreboard with an optional side sponsor panel. The side sponsor panel is a separate assembly that bolts to the side of the scoreboard.

6 1260 Page 6 8' 20' 8' 8' WATHRPROO CONVNINC RCPTACL POWR CABL IN 3/4" CONDUIT POWR DISCONNCT #6 BAR COPPR GROUND WIR 5/8" BRASS TAR DROP CONNCTOR 5/8" X 8' COPPR CLAD GROUND ROD CONTROL CABL IN 3/4" CONDUIT TO CONTROL LOCATION TO POWR SOURC 10' igure with Side Sponsor Panel Post Spacing igure 3 shows the spacing of the posts for a 1260 scoreboard with two optional side sponsor panels. The side sponsor panels are separate assemblies that bolt to the sides of the scoreboard.

7 1260 Page 7 28' 8' 8' 8' 8' WATHRPROO CONVNINC RCPTACL POWR CABLIN 3/4" CONDUIT POWR DISCONNCT #6 BAR COPPR GROUND WIR 5/8" BRASS TAR DROP CONNCTOR 5/8" X 8' COPPR CLAD GROUND ROD CONTROL CABL IN 3/4" CONDUIT TO CONTROL LOCATION TO POWR SOURC 10' igure with Two Side Sponsor Panels Post Spacing igure 4 shows the spacing of the posts for a 1260 scoreboard with an optional top sponsor panel. This panel is a separate unit that mounts on the same posts as the scoreboard.

8 1260 Page 8 12' 8' 33" 8' WATHRPROO CONVNINC RCPTACL POWR CABL IN 3/4" CONDUIT POWR DISCONNCT #6 BAR COPPR GROUND WIR 5/8" BRASS TAR DROP CONNCTOR 5/8" X 8' COPPR CLAD GROUND ROD CONTROL CABL IN 3/4" CONDUIT TO CONTROL LOCATION TO POWR SOURC 10' igure with Top Sponsor Panel Post Spacing Mounting The Scoreboard The scoreboard is attached to the posts at four points. igure 5 shows the location of the mounting points on the rear of the scoreboard.

9 LI CH AN GIN M SS AG TYP CONORMS TO ANSI/UL-1433 & ANSI/UL-48 S T D R US TL LISTD LCTRIC SIGNS AND CONTROL CNTRS OR LCTRIC SIGNS LCTRO- MCH SCORBOARD CO. #3 Industri al Parkway P.O. Box 102 Wrightsville, GA Mode l No. M M Ser ial No. AB- Date of Mfg. 120 VAC 60 Hz 13.3 A No. of la mpholde rs 10 7 Replace with 15 W lamp, maximum CAUTION lectric shock hazard: Disconnect power before servicing equipment C hec k w ith t he applicable st at e and local codes before installation 1260 Page 9 MOUNTING POINT #1 MOUNTING POINT #2 igure 5 Mounting Points MOUNTING POINT #3 MOUNTING POINT #4 MOUNTING HARDWAR our sets of mounting hardware are provided to attach the scoreboard at these points. Additional hardware sets are provided to attach the optional top sponsor panels, if ordered. A single set of mounting hardware for the scoreboard consists of a steel angle bracket, two threaded rods, two washers, and two nuts. A single set of mounting hardware for an optional top sponsor panel consists of a steel angle bracket, two threaded rods, four washers, and four nuts. igure 6 shows an overhead cross section view and a side cross section view of the scoreboard attached to a post at a mounting point. A steel bar is riveted inside the scoreboard s aluminum extrusion frame. The bar has two tapped holes. The threaded rods screw into these tapped holes. The washers and nuts are used to clamp the steel angle bracket against the steel post and hold the scoreboard in place.

10 1260 Page 10 xtrusion Lip Scoreboard Back Threaded Rod Steel Angle Bracket Overhead Cross Section View 1/4-Inch lat Bar With Tapped Holes Nut Washer 7-Inch Steel Post 7-Inch Steel Post Steel Angle Bracket Nut Washer Side Cross Section View Aluminum rame xtrusion Scoreboard ace Threaded Rod 1/4-Inch lat Bar With Tapped Holes Scoreboard Back igure 6 Standard Mounting Method The following steps describe how to mount the scoreboard on the posts: 1. Place the scoreboard cabinet against the posts on the ground. Make sure the mounting points are aligned with the posts. 2. Screw the threaded rods into the tapped holes in the scoreboard. 3. Place a steel angle bracket over the threaded rods at mounting point #1. 4. Place a washer over each threaded rod. 5. Screw the nuts onto the threaded rods so that the bracket is loosely held in place. 6. Repeat steps 3-6 at the other mounting points. 7. Raise the scoreboard into place and tighten the nuts to clamp the scoreboard in place on the posts. Note: Be sure to leave enough space on the posts above the scoreboard for the optional top sponsor panel, if purchased.

11 1260 Page 11 Mounting The Optional Side Sponsor Panel If you purchased the optional side sponsor panel, the scoreboard has been modified so that the sponsor panel bolts to the side of the scoreboard cabinet. our bolts and washers are provided to attach the side sponsor panel to the scoreboard. The following steps describe how to attach the sponsor panel to the scoreboard and mount the optional side sponsor panels on the posts: 1. There are four small access panels on the rear of the side sponsor panel. Remove these access panels. 2. Position the sponsor panel next to the scoreboard. 3. Screw the threaded rods into the tapped holes at one of the sponsor panel mounting points. 4. Place an aluminum angle bracket over the threaded rods at the mounting point. 5. Place a washer over each threaded rod. 6. Screw the nuts onto the threaded rods so that the bracket is loosely held in place. 7. Repeat steps 3-6 at the other mounting point. 8. Place a washer over a bolt. 9. Insert the bolt into the top sponsor access panel opening and through the hole in the frame. 10. Screw the bolt into the tapped hole in the scoreboard cabinet. 11. Repeat steps 8-10 at the other three access panel openings. 12. Tighten the nuts to clamp the sponsor panel in place on the post. 13. Re-install the access panels. Mounting The Optional Top Sponsor Panel Additional hardware sets are provided to attach the optional top sponsor panels, if purchased. The following steps describe how to mount the top sponsor panel on the posts: 1. Raise the top sponsor panel in place above the scoreboard. Make sure the mounting points are aligned with the posts. 2. Place the threaded rods through the mounting holes in the top sponsor panel at one mounting point. 3. Place a washer over each threaded rod inside the frame of the top sponsor panel. 4. Screw a nut onto each threaded rod behind the washers inside the frame of the top sponsor panel. 5. Place a steel angle bracket over the threaded rods behind the post. 6. Place a washer over each threaded rod behind the bracket. 7. Screw a nut onto each threaded rod so that the bracket is loosely held in place. 8. Repeat steps 2-7 at the other mounting points. 9. Tighten the nuts to clamp it in place on the posts.

12 LCTRO-MCH SCORBOARD CO. #3 Indu strial Parkway P.O. Box 102 Wrightsvill e, G A Mod el No. MM-1000 S erial No. AB- Date of Mfg. 120 VAC 60 Hz 13.3 A No. of lam pholders 107 Replace with 15 W lamp, maximum CAUTION lectric shock hazard: Disconnect power before servicing equipment Check with the applicable state and local codes before installation 1260 Page 12 LCTRICAL INSTALLATION We recommend a qualified electrician perform the needed electrical connections to ensure proper operation of the scoreboard. These connections include grounding the scoreboard, connecting the scoreboard to a power source, installing the ScoreLink 300 or the control cable, and connecting the control console. Ground Connection The National lectrical Code requires a scoreboard (electric sign) to be grounded. Grounding the scoreboard helps the scoreboard electronics operate properly and helps minimize damage if it is struck by lightning. Metal posts do not provide an adequate ground path. The following steps describe how to connect the scoreboard to the power source: 1. Drive one or more 5/8 x 8 copper clad ground rods in the soil near the scoreboard. 2. Connect #6 bare copper wire to the ground rods using 5/8 brass tear drop connectors. 3. Remove the rear access panel and the dome plugs on the plate below the access panel. igure 7 shows the location of the access panel and the dome plugs. DOM PLUG ACCSS PANL igure 7 Rear Access Panel

13 Black Red Shield S S U S U S Test Jack Model: Serial Number: LPS5 JAN 2003 Scoreboard Company 3 Industrial Parkway, Wrightsville, GA Replace with fuses of same type and rating only. 1/2A 1A S U S 3A 5A 5A S U S S ATTNTION: Observe precautions for handling electrostatic sensitive devices. Model: LDM14 Serial Number: JAN 2003 Scoreboard Company 3 Industrial Parkway, Wrightsville, GA No user replaceable parts inside; return to factory for repair. AC-L AC-N U S S S Model: Serial Number: LPS7 JAN Industrial Parkway, Wrightsville, GA Replace with fuses of same type and rating only. S S S 3A 5A 5A 1260 Page igure 8 shows the view behind the access panel. J24 J23 J22 J21 J20 J19 J18 J17 J16 J15 J14 J13 LDM14 J12 J11 J10 J9 J8 lectro-mech J7 J6 J5 J4 J3 J2 J1 LD POWR INTRAC BOARD lectro-mech S lectro-mech Scoreboard Company LPS5 Control Cable Main Power Ground LPS7 igure 8 Access Panel Removed 5. Pass the ground conductor through the right hand hole in the plate below the access panel and connect it to the ground lug (Ground) on the junction chassis. Power Connections The scoreboard requires 120 VAC service at the scoreboard to operate properly. Maximum power consumption of Model 1260: 156 Watts. Make sure that power cable is rated for this electrical load. Install the power cable in conduit. Avoid running the power cable in close proximity to the control cable. The following steps describe how to connect the scoreboard to the power source: 1. eed the power cable through the middle hole in the plate below the access panel. 2. Crimp fork terminals to the power cable wires. 3. Connect the AC line wire and AC neutral wire to the Main Power terminal block on the junction chassis according to igure 9.

14 1260 Page 14 AC-L AC-N Main Power igure 9 Power Connections Install a power disconnect that isolates all current carrying conductors on one of the posts below the scoreboard (not the ground conductor). If a secondary switch is installed near the scorekeeper s table, it should also isolate these conductors. Place the power disconnect in the O position between games to help protect the scoreboard from lightning damage. A power disconnect on the scoreboard post also provides a convenient way of turning the scoreboard off during maintenance or repairs. ScoreLink 300 The ScoreLink 300 R MODM SYSTM is designed to eliminate the control cable between the scoreboard and the control console on lectro-mech Scoreboard MM and MP series scoreboards as well as all LD scoreboards. If you have purchased this accessory, disregard the section of this manual titled Control Cable Installation. Refer to the ScoreLink 300 R MODM SYSTM OWNR S HANDBOOK for installation instructions. Control Cable Installation The control cable connects the scoreboard to the control console. Install the control cable in conduit. If the cable is ever damaged, it is easier and less expensive to replace a cable in conduit. A small junction box with a ¼ stereo jack mounted on the face plate is attached to the control cable at the point of operation of the scoreboard. This junction box should be securely mounted in a clean, dry area within ten feet of the rear of the control console. Most customers order the control cable with the junction box attached. Some customers prefer to attach the junction box after the cable is installed. Those customers must solder the control cable to the ¼ stereo jack. igure 10 shows the control cable wire connection points on the rear of the ¼ stereo jack.

15 1260 Page PIN 1 - BLACK WIR PIN 2 - RD WIR PIN 3 - SHILD WIR igure 10 ¼ Stereo Jack Wiring Diagram The following steps describe how to connect the control cable to the scoreboard: 1. At the rear of the scoreboard, feed the control cable through the left hole in the plate below the access panel. 2. Crimp fork terminals to the control cable wires and the shield. 3. Connect the control cable to the Control Cable terminal block on the junction chassis according to igure 11. Black Red Shield Control Cable igure 11 Control Cable Wiring Diagram 4. Reinstall the access panel.

16 1260 Page 16 Control Console Connections The 10 ft. extension cable has two molded ¼ stereo plugs attached to it. It is used to connect the control console to the junction box. The following steps describe how to connect the control console: 1. Plug one end of the extension cable into the ¼ stereo jack on the junction box or the ScoreLink 300 Transmitter, if purchased. 2. Plug the other end into the ¼ stereo jack mounted on the control console back plate. 3. Plug the control console power cord into a grounded NMA 5-15R 120 VAC receptacle. Control Console Safety Warning This product is equipped with a 3-wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact a qualified electrician to replace your obsolete outlet. Do not defeat the purpose of the groundingtype plug.

17 1260 Page 17 SCORBOARD OPRATION SCORBOARD STARTUP 1. Place the power disconnect for the scoreboard in the ON position. 2. Plug one end of the 10 ft. extension cable into ¼ stereo jack on the junction box or the ScoreLink 300 Transmitter, if purchased. 3. Plug the other end into the ¼ stereo jack mounted on the control console back plate. 4. Plug the control console power cord into a grounded NMA 5-15R 120 VAC receptacle. 5. If a ScoreLink 300 R MODM SYSTM is installed with this scoreboard, plug the wall mount DC power supply into a grounded NMA 5-15R 120 VAC receptacle and the male plug on the end of the attached cable into the Power jack on the Transmitter. GAM TIM OPRATION This scoreboard is operated with a simple 15-key control console. igure 12 shows the keypad layout on the control console. lecto-mech Scoreboard Co NW GAM BASBALL SOTBALL GUST +10 GUST +1 CLOCK RST HOM +10 HOM +1 HIT MIN -1 CLOCK ON / O SC -1 RROR BALL STRIK OUT INNING igure 12 Keypad Layout

18 1260 Page 18 Control Console Key unctions 1. GUST +1 This key increments the Guest score by HOM +1 This key increments the Home score by GUST +10 This key increments the Guest score by HOM + 10 This key increments the Home score by INNING This key increments the Inning by BALLS This key increments the Ball count by STRIKS This key increments the Strike count by OUTS This key increments the Out count by HIT This key activates the blinking Hit indicator. 10. RROR This key activates the blinking rror indicator. 11. NW GAM This key is used with the CLOCK RST key to reset all scoreboard functions. Press [NW GAM] and, within two seconds, press [CLOCK RST]. The HOM score, GUST score, and INNING will display zero. The BALLS, STRIKS, and OUTS will be blanked. 12. CLOCK RST This key is used only in conjunction with the NW GAM key. The DC. MIN., DC. SC., and CLOCK ON/O keys are not used with the 1260 scoreboard. You should reset the scoreboard each time that it is turned on. Test all the functions to ensure that the scoreboard is operating properly. SCORBOARD SHUTDOWN 1. Place the power disconnect for the scoreboard in the O position. 2. Unplug the control console power cord. 3. Unplug the 10 ft. extension cable. 4. If a ScoreLink 300 R MODM SYSTM is installed with this scoreboard, unplug the Transmitter s wall mount power supply. 5. Store the control console and ScoreLink 300 transmitter in a dry location. These units are not waterproof. Proper scoreboard shutdown will help protect the scoreboard and control console from power surges and lightning strikes.

19 1260 Page 19 SRVICING TH SCORBOARD While your scoreboard was designed for years of trouble-free operation, some problems may occasionally occur. lectro-mech Scoreboard Company offers onsite service in some areas. In other areas, we can help you contact an independent service technician. In areas in which service is not available from lectro-mech Scoreboard Company, we will make every effort to answer your questions. Our trained personnel at lectro-mech Scoreboard Company are ready to answer your questions from Monday to riday during the hours of 8 AM to 5 PM astern Standard Time. Be sure to know your scoreboard model number when calling. Scoreboard replacement parts are always available. Damaged parts can usually be repaired at a significant cost savings. Our convenient toll free number is listed at the bottom of every page in this manual. If the scoreboard turns on LDs, but does not operate normally, make note of which functions are affected. If some LDs either never turn on or always stay on, make note of their specific locations on the scoreboard. Refer to the COMPONNT RPLACMNT section of this manual before changing parts. COMPONNT RPLACMNT LD digits and indicators are serviced from the front of the scoreboard. LD Digits And Indicators Replacement The LDs that form digits and indicators are soldered on circuit boards mounted behind metal masks. Do not attempt to replace individual LDs. In case of a malfunction, the entire LD circuit board must be removed. To avoid damage to the LD driver module, always turn off the power to the scoreboard when removing or replacing LD digits and indicators. igure 13 shows the components of an LD digit assembly. LD indicator assemblies are similar in construction.

20 1260 Page 20 1/8" SPACR 6-32 KP LOCK NUT MASK igure 13 LD Digit Assembly LD DIGIT 1. Remove the sheet metal screws that fasten the mask to the face of the scoreboard. Caution: Support the mask before removing the last screw. The ribbon cable that connects to the rear of the circuit board is not designed to support the weight of the assembly. 2. Disconnect the ribbon cable from the rear of the circuit board. Caution: Do not let the cable hang outside of the scoreboard. It is easily cut by sharp metal edges. Damage to the ribbon cable may create short circuit paths that will damage the LDM14 LD driver module. 3. Place the assembly on a flat surface and remove the 6-32 kep lock nuts that hold the circuit board in place. 4. Remove the old circuit board. 5. Align the mounting holes in the new circuit board with the threaded studs on the mask and install the replacement digit on the mask. 6. Plug the ribbon cable onto the header on the back of the circuit board. 7. The circuit board used for the HIT and RROR indicators has two headers. Refer to igure 14 in order to plug the ribbon cable IDC connector onto the correct header on the circuit board in the proper orientation.

21 Black Red Shield S S U S U S Test Jack Model: Serial Number: LPS5 JAN 2003 Scoreboard Company 3 Industrial Parkway, Wrightsville, GA Replace with fuses of same type and rating only. 1/2A 1A S U S 3A 5A 5A S U S S ATTNTION: Observe precautions for handling electrostatic sensitive devices. Model: LDM14 Serial Number: JAN 2003 Scoreboard Company 3 Industrial Parkway, Wrightsville, GA No user replaceable parts inside; return to factory for repair. AC-L AC-N U S S S Model: Serial Number: LPS7 JAN Industrial Parkway, Wrightsville, GA Replace with fuses of same type and rating only. S S S 3A 5A 5A 1260 Page 21 RIBBON CABL IDC SOCKT CABL B ( h seg ) A ( f seg ) CNTR KY CNTR KY ON RIBBON CABL IDC SOCKT MUST POINT IN TH SAM DIRCTION AS TH ARROW ON TH RAR O TH LD DIGIT. igure 14 Hit and rror Ribbon Cable Connection Diagram All other components are located behind the rear access panel. igure 15 shows the view behind the access panel. J24 J23 J22 J21 J20 J19 J18 J17 J16 J15 J14 J13 LDM14 J12 J11 J10 J9 J8 lectro-mech J7 J6 J5 J4 J3 J2 J1 LD POWR INTRAC BOARD lectro-mech S lectro-mech Scoreboard Company LPS5 Control Cable Main Power Ground LPS7 igure 15 Access Panel Components

22 1260 Page 22 LDM14 LD DRIVR MODUL NCTIONS DRIVR MODUL JACK NCTION J1 DRIVR MODUL DC POWR INPUT #1 J2 J7 J8 J9 J10 J11 J12 SRIAL DATA INPUT HOM SCOR UNITS DIGIT HOM SCOR TNS DIGIT, INNING TN DIGIT GUST SCOR UNITS DIGIT BALL DIGIT STRIK DIGIT OUT DIGIT J13 DRIVR MODUL DC POWR INPUT #2 J15 HIT INDICATOR (HADR A) J19 INNING UNITS DIGIT J20 GUST SCOR TNS DIGIT, RROR INDICATOR (HADR H) LD Driver Module Replacement lectrical connections to the LDM14 LD DRIVR MODUL are made with ribbon cable polarized IDC sockets and locking ramp crimp terminal housings that mate with jacks on the module. The module is secured inside the scoreboard with six machine screws. 1. Unplug the electrical connections from the module. Do not cut the plastic tie wraps around the ribbon cables. 2. Remove the six screws. 3. Remove the module from the scoreboard. 4. Insert the replacement module in the scoreboard. 5. Secure the module with the six screws. 6. Insert the plugs into the jacks on the module. To avoid damage to the module, always turn off the power to the scoreboard when removing or replacing it. LPS5 LD POWR SUPPLY MODUL NCTIONS JACK NCTION J1 120 VAC INPUT J2 20 VDC OUTPUT TO LD POWR INTRAC BOARD J3 SRIAL DATA INPUT / OUTPUT J4 12 VDC RLAY NCTIONS (NOT USD ON THIS SCORBOARD) J5 SRIAL DATA TST JACK A relay inside the LPS5 Power Supply Module isolates the LDM14 LD Driver Module from the control cable when the scoreboard is shut down. Connecting the control console to J5 with the 10 ft. extension cable bypasses this relay. igure 16 shows the location of the fuses in the LPS5 LD Power Supply Module. The table following the figure lists the fuse ratings, functions, and part numbers.

23 1260 Page 23 Not a convenience receptacle This receptacle is designed for use with lectro-mech control consoles only. US US US 6 1/2 A J5 Test Jack Model: Serial Number: LPS5 JAN 2003 lectro-mech Scoreboard Company 3 Industrial Parkway, Wrightsville, GA J4 Replace with fuses of same type and rating only. J3 J2 J S S U S S 1/2A 1A S 3A 5A 5A S S S S S 3 igure 16 LPS5 use Locations LPS5 SS S RATING NCTION BUSSMAN PART # 1 3A 250V TRANSORMR PRIMARY AGC-3 2 5A 250V LD POWR INTRAC BOARD J1 AGC-5 3 5A 250V LD POWR INTRAC BOARD J6 AGC-5 4 ½A 250V SRIAL DATA ISOLATION RLAY AGC-1/2 5 1A 250V 12 VDC RLAY OUTPUT (NOT USD ON THIS SCORBOARD) AGC-1 6 ½A 250V 120 VAC LCTRICAL RCPTACL AGC-1/2 Note: Other manufacturers fuses may be substituted for the Bussmann fuses. LPS7 LD POWR SUPPLY MODUL NCTIONS JACK NCTION J1 120 VAC INPUT J2 20 VDC OUTPUT TO LD POWR INTRAC BOARD igure 17 shows the location of the fuses in the LPS7 LD Power Supply Module. The table following the figure lists the fuse ratings, functions, and part numbers.

24 1260 Page 24 J2 J1 S 3A 5A 5A S U S S S U S Model: Serial Number: LPS7 JAN 2003 lectro-mech Scoreboard Company 3 Industrial Parkway, Wrightsville, GA Replace with fuses of same type and rating only. igure 17 LPS7 use Locations LPS7 SS S RATING NCTION BUSSMAN PART # 1 3A 250V TRANSORMR PRIMARY AGC-3 2 5A 250V LD POWR INTRAC BOARD J11 AGC-5 3 5A 250V LD POWR INTRAC BOARD J16 AGC-5 Note: Other manufacturers fuses may be substituted for the Bussmann fuses. LD Power Supply Module Replacement lectrical connections to the LPS5 and LPS7 LD Power Supply Modules are made with keyed plugs that mate with jacks on the left side of the module. The modules are secured inside the scoreboard with four machine screws each. 1. Disconnect the plugs from the jacks on the side of the module. 2. Remove the four screws. 3. Remove the module from the scoreboard. 4. Insert the replacement module in the scoreboard. 5. Secure the module with the four screws. 6. Insert the plugs into the jacks on the side of the module. To avoid damage to the module, always turn off the power to the scoreboard when removing or replacing it. The LD power interface board distributes the output from the LPS5 and LPS7 power supply modules to the LDM14 LD driver module and to some digits.

25 1260 Page 25 LD Power Interface Board Replacement 1. Unplug the wire assemblies from the jacks on the circuit board. 2. The circuit board is mounted on snap-in standoffs. Unseat the circuit board from the standoffs. 3. Press the replacement circuit board in place on the standoffs. 4. Plug the wire assemblies in the correct jacks on the circuit board. ach wire assembly is labeled to indicate the correct jack connection.

26 1260 Page 26 LCTRO-MCH SCORBOARD CO. IV YAR LIMITD WARRANTY TH LCTRICAL COMPONNTS O ALL LCTRO-MCH SCORBOARDS AR GUARANTD OR A PRIOD O IV (5) YARS ROM TH DAT O INVOIC AGAINST DCTS IN WORKMANSHIP OR MATRIAL AND WILL B RPLACD OR RPAIRD WITHOUT COST TO TH OWNR PROVIDD TH QUIPMNT OR PARTS AR RTURND POSTAG-PAID TO TH ACTORY IN WRIGHTSVILL, GA. SHIPPING BACK TO TH OWNR WILL B VIA UPS GROUND SRVIC XCPT WHN AIR OR SPCIAL MTHOD O RTURN IS SPCIID BY TH OWNR, IN WHICH CAS SHIPPING WILL B RIGHT COLLCT. XCLUDD ROM THIS WARRANTY AR SS. THIS WARRANTY DOS NOT INCLUD LABOR CHARGS INCURRD IN TH RMOVAL O COMPONNT PARTS, SRVIC CALLS, OR DAMAGS RSULTING ROM IMPROPR INSTALLATION, IMPROPR OPRATION, OR PROBLMS CAUSD BY ANY RPAIR, ALTRATION OR MODIICATION O TH SCORBOARD NOT PRORMD BY LCTRO-MCH. QUIPMNT WHICH IS SUBJCTD TO ACCIDNT, NGLCT, ABUS, MISUS OR OTHR NATURAL DISASTRS, INCLUDING BUT NOT LIMITD TO IR, WIND, LIGHTNING, OR LOOD, IS NOT COVRD BY THIS GUARANT.

ELECTRO-MECH SCOREBOARD CO BASKETBALL SCOREBOARD OWNER S HANDBOOK

ELECTRO-MECH SCOREBOARD CO BASKETBALL SCOREBOARD OWNER S HANDBOOK ELECTRO-MECH SCOREBOARD CO. GUEST POSS BONUS : HOME BONUS POSS PERIOD 7250 BASKETBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2180 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MM-338 FOOTBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MP-140 BASEBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MP-374-TK FOOTBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

CAUTION: Do not install damaged parts!!!

CAUTION: Do not install damaged parts!!! Your satisfaction is important to us, plas lt us hlp! If you hav any qustions or concrns during th installation, our support rprsntativs ar availabl to assist you. Plas call: 1-877-769-3765 or Liv Chat

More information

Invitation to Bid BOE. Scoreboards Soccer-Softball-Baseball For Various Schools

Invitation to Bid BOE. Scoreboards Soccer-Softball-Baseball For Various Schools Invitation to Bid 20170328-3-BOE Scoreboards Soccer-Softball-Baseball For Various Schools Responses to an Invitation to Bid will be received by the Purchasing Supervisor, Sumner County Board of Education,

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL EFFECTIVE S.N.XXXX, JAN 1, 1994 TABLE OF CONTENTS 1. General Information 1.1 Description 1.2 Identification

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASEBALL SCOREBOARD MODEL MP-3310 WITH MP-2002 CONTROL

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASEBALL SCOREBOARD MODEL MP-3310 WITH MP-2002 CONTROL OPERATING INSTRUCTIONS AND SERVICE MANUAL BASEBALL SCOREBOARD MODEL MP-3310 WITH MP-2002 CONTROL EFFECTIVE S.N.XXXX, APRIL 1, 1996 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER

More information

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP Warning for Your Protection 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings.

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL COUNTDOWN TIMER. MODEL MP-3905 WITH MP-2002 Control

OPERATING INSTRUCTIONS AND SERVICE MANUAL COUNTDOWN TIMER. MODEL MP-3905 WITH MP-2002 Control OPERATING INSTRUCTIONS AND SERVICE MANUAL COUNTDOWN TIMER MODEL MP-3905 WITH MP-2002 Control EFFECTIVE S.N. 17155 May 18, 2001 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification

More information

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC Warning for Your Protection 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.

More information

TK TRACK LED SCOREBOARD S.O INSTRUCTION MANUAL REVISION DATE: PART#:

TK TRACK LED SCOREBOARD S.O INSTRUCTION MANUAL REVISION DATE: PART#: TK-1373-2 TRACK LED SCOREBOARD S.O.67587 INSTRUCTION MANUAL REVISION DATE: 06-04-09 PART#: 98-1375-01 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL RACETRACK SCOREBOARD MODEL MP-3805

OPERATING INSTRUCTIONS AND SERVICE MANUAL RACETRACK SCOREBOARD MODEL MP-3805 OPERATING INSTRUCTIONS AND SERVICE MANUAL RACETRACK SCOREBOARD MODEL MP-3805 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 DESCRIPTION 1.2 IDENTIFICATION 1.3 DAMAGE 1.4 DAMAGE CLAIM PROCEDURE 2. INSTALLATION

More information

Senior Swing Control Box. Table of Contents

Senior Swing Control Box. Table of Contents *740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

SPECIAL SPECIFICATION 6894 Communication Cabinet

SPECIAL SPECIFICATION 6894 Communication Cabinet 2004 Specification CSJ 0353-04-085, etc. SPECIAL SPECIFICATION 6894 Communication Cabinet 1. Description. Furnish and install communication cabinet to include the installation of the foundation, cabinet,

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 AQUALUMIN III NICHELESS POOL LIGHT INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

SPECIAL SPECIFICATION 1788 Surveillance Cabinet 1993 Specifications CSJ 2266-02-095 SPECIAL SPECIFICATION 1788 Surveillance Cabinet 1. General. This Item shall govern the furnishing and installation of Surveillance Cabinet to include the installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable. 5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL Exterior Cutout TILE Exterior TILE Jumper Cable T-Cable End Cap Cable Clamp Power Supply Control Module Waterproof

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL PRODUCTION COUNTER. MODEL MP-3911 WITH MP-2002 Control

OPERATING INSTRUCTIONS AND SERVICE MANUAL PRODUCTION COUNTER. MODEL MP-3911 WITH MP-2002 Control OPERATING INSTRUCTIONS AND SERVICE MANUAL PRODUCTION COUNTER MODEL MP-3911 WITH MP-2002 Control EFFECTIVE S.N. 17255 September 13, 2001 TABLE OF CONTENTS - 1. General Information 1.1 Description 1.2 Identification

More information

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877 CAT-1 Series 3 Installation Guide The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877 (203) 431-0262 (203) 431-0296 FAX tvg@cat-1.com Installation of Load Cells for CAT-1 Systems

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY. MODEL MP-3913 WITH MP-2002 Control

OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY. MODEL MP-3913 WITH MP-2002 Control OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY MODEL MP-3913 WITH MP-2002 Control EFFECTIVE S.N. 18225 May 6, 2002 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification 1.3

More information

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices. 5 YEAR WARRANTY 5 YEAR WARRANTY COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS E354088 LISTED AC E354088 58VDC E354088 E354088 5 5 YEAR WARRANTY 5 YEAR WARRANTY E354088 Caution: Observe precautions for

More information

BLACKBIRD WIRING MANUAL

BLACKBIRD WIRING MANUAL BLACKBIRD WIRING MANUAL VERSION ZX120 5/09 TO BE USED IN CONJUNCTION WITH A VEHICLE-SPECIFIC INSTALLATION SUPPLEMENT System Capabilities The 5kW Blackbird will provide 42 amperes of 120 Volt alternating

More information

INTEGRID TRACK (120V) SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to

More information

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the

More information

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ITS-50R TRANSFER SWITCH OWNER S MANUAL ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard

More information

WSK-SOUL-TMR INSTALLATION AND OPERATING INSTRUCTIONS

WSK-SOUL-TMR INSTALLATION AND OPERATING INSTRUCTIONS WSK-SOUL-TMR INSTALLATI AND OPRATING INSTRUCTIS Note: In addition to these instructions read and follow instructions in gas appliance Owner s Guide. INTRODUCTI Hearth & Home Technologies wireless wall

More information

SURFACE TRACK (120/250V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed

More information

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN ELMEC Inc. Rev.: June 2016 TABLE OF CONTENTS Overview (Models 4, 5, 30 and 31) 2 Parts List 3 Operation Sequence 10 Operating Modes

More information

The Power of Reliability INSTRUCTION MANUAL

The Power of Reliability INSTRUCTION MANUAL The Power of Reliability INSTRUCTION MANUAL SAFETY & WARNINGS Read this manual carefully and understand all Warnings and Cautions before connections are made to the Inverter. If unsure about any aspects

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Dimmer Power Module - through 5 READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS! WARNING To reduce the risk of death, injury

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL MODEL MP-3903 TIMER

OPERATING INSTRUCTIONS AND SERVICE MANUAL MODEL MP-3903 TIMER OPERATING INSTRUCTIONS AND SERVICE MANUAL MODEL MP-3903 TIMER EFFECTIVE S.N. 16,600, FEB. 28, 2001 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification 1.3 Damage 1.4 Damage Claim

More information

SPACESAVER EC-300 A ELECTRICS

SPACESAVER EC-300 A ELECTRICS INSTALLATION INSTRUCTIONS SPACESAVER EC-300 A ELECTRICS SECTION I TOP MOUNTED ELECTRICS SECTION II FACE PANEL MOUNTED ELECTRICS SECTION III ZFS INSTALLATION INSTRUCTIONS This symbol indicates a connection

More information

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 16 1 AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color

More information

RU SERIES UPGRADE TempAssure Compatible

RU SERIES UPGRADE TempAssure Compatible RU SERIES UPGRADE TempAssure Compatible This converter section has been designed as a converter section replacement in the following MagneTek or Parallax Power Supply series products and models with DC

More information

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS PLEASE NOTE Installation instructions must be strictly followed in compliance with Intrinsic Safety National Standard NEC 504 or ANSI/ISA

More information

Assembly Instructions MP-P2 Power Supply and Chassis Base Plate

Assembly Instructions MP-P2 Power Supply and Chassis Base Plate Assembly Instructions MP-P2 Power Supply and Chassis Base Plate The MP-P2 Power Supply is the supply designed to power the mother board and its complement of plug-on boards including the MP-09 Microprocessor

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...

More information

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT! Limited Warranty Statement GNU COMMANDO LINE WARRANTY STATEMENT GNU warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of sale to the original

More information

XENON POWER SUPPLY 4000 Watt Gladiator IV

XENON POWER SUPPLY 4000 Watt Gladiator IV XENON POWER SUPPLY 4000 Watt Gladiator IV 220 Volt Equipment Type 62-00049 Rev. February 2003 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska 68112 USA

More information

CLASS # GAUGE ROUND POWER CORDS

CLASS # GAUGE ROUND POWER CORDS 16 GAUGE ROUND POWER CORDS These 16 gauge, 3 wire orange power cords will stay flexible down to -40. They feature a heavy duty double vinyl jacket insulation and molded male and female ends. The cords

More information

Measurements are expressed in millimeters.

Measurements are expressed in millimeters. T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164

More information

Connecting to DC Power

Connecting to DC Power APPENDIXC This appendix describes how to make DC power connections to the Catalyst 3750G-12S-SD switch. See the Installing the Switch section on page 2-11 for instructions on installing the switch. To

More information

Instruction Book for. ContouR ElECtRol

Instruction Book for. ContouR ElECtRol Instruction Book for ContouR ElECtRol IMPORTANT SAFETY INSTRUCTIONS When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand

More information

WARNING. Important Notice

WARNING. Important Notice CAL (Color AquaLuminator ) Light and Return Water Flow for Above Ground Pools Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION

More information

Operations and Service Manual. X30208 Load Bank

Operations and Service Manual. X30208 Load Bank Operations and Service Manual Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a)... 4 3) Receiving... 5 4) Safety... 5 a) Ground

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

Dor-O-Matic. Series Slide Control. Installation Instructions

Dor-O-Matic. Series Slide Control. Installation Instructions Dor-O-Matic Series 96000 Slide Control Installation Instructions DOR - O MATIC 7350 W. Wilson Ave. Harwood Heights, IL 60706 Toll Free: 1-800-543-4635 In Illinois: 708-867-7400 Sales FAX: 708-867-0291

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

LED Downlight Ceiling Fixtures

LED Downlight Ceiling Fixtures ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. PD9100 / 9200 SERIES POWER CONVERTER OWNERS MANUAL PROGRESSIVE DYNAMICS, INC. POWER CONVERTER LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power converter to be free from

More information

Model LA 4400 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller ISIMET LA Series Model LA 4400 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller with integral 24-hr. programmable time clock operates

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8 ITEM #0776 7. FT. PRE-LIT DOUGLAS FIR TREE MODEL #DF-7C8 Español p. 8 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our

More information

GMT Fuse Panel Installation Guide

GMT Fuse Panel Installation Guide GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

EXTRA LARGE OUTDOOR HOUSINGS

EXTRA LARGE OUTDOOR HOUSINGS EXTRA LARGE OUTDOOR HOUSINGS ws Camera Spacer Heater Rails Bushing Power Cable Screw Ground Wire Terminal Lug HS9386 SERIES M4 Captive Screws I N STALLATION AND O P E R A TING I N STRU CTIONS W W W. AIG

More information

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family TPM Fuse Panel Installation Guide Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS: All wiring must be performed by a qualified electrician. Basic safety precautions and local codes should be observed

More information

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP AI85112-02 Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN 858-003-02/SKT 858-032-02 CABLE: 963-033-26 S/FTP Revision History Rev Date Initiated By Approved 1 07/05/18 WLL

More information

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL SX-16 Nightsun Searchlight Safety and Service Bulletin # SL 0898-02 Issue Date: 09/25/98 Amended Date: 02/09/06 Subject: SX-16 Nightsun Junction Box Wiring Modification Affected Products: All SX-16 Nightsun

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

Electro-Mechanical Swing Operator. Table of Contents

Electro-Mechanical Swing Operator. Table of Contents *640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product

More information

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf Type: Catalog number: / / Wattage / Lamp(s) Finish Options: See page 2 ing Options: See pages 3-5: Approvals: Date: Page: 1 of 5 Specifications ORDERING INFORMATION Light Engine Length l 4324P70 / 16L3KUV

More information

MASTERsine Inverter PXA Series Installation Guide

MASTERsine Inverter PXA Series Installation Guide Backup Power System Expert TM MASTERsine Inverter PXA Series Installation Guide Important Safety Instructions IMPORTANT: Read and save this Installation Guide for future reference. This chapter contains

More information

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree 7' Diamond Peak LED Tree ASSEMBLY INSTRUCTIONS MODEL NO: U11G684A-024-01 (WL-019) PRODUCT CODE: 140-034067-090 CAUTION: Carefully Read Instructions and Procedures for Safe Operation. Receipt of Purchase:

More information

Elegance Electrician s Installation Guide

Elegance Electrician s Installation Guide Elegance Electrician s Installation Guide CentraLite Systems, Inc. 6420 Wall St. Mobile, AL 36695 Phone: 877-466-5483 Fax: 251-607-9119 2003-2005 CentraLite Systems, Inc. Revised 10/20/2005 ELECTRICIAN

More information

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-9 ACSI MODEL 1400-6100 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Used exclusively with the ACSI Series 6100 Communicating Bath Door (Common Bath) System Two separate and identical rows of

More information

Installation Instructions

Installation Instructions Bi-Level Control Module For fixtures with CWA transformers and non-encased capacitors, using Metal Halide, Metal Halide (Pulse Start) or High Pressure Sodium lamps between 75-000W Model#s: -250H -400H

More information

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A) TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user

More information

Electrical Wiring Practices

Electrical Wiring Practices Chapter 2 Electrical Wiring Practices and Diagrams MElec-Ch2-1 Overview Safety Standards Wiring Considerations Wire Terminations Coaxial Cable Wiring Installations Wiring Diagrams MElec-Ch2-2 Safety Lethal

More information

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit NIPPON ANEMOMETER TO HYBRID XT ANEMOMETER RETROFIT KIT, MITSUBISHI, NEI (9370) NIPPON YAW VANE TO HYBRID XT VANE RETROFIT KIT, MITSUBISHI, NEI (9371)

More information

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax: Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS

More information

Operations Manual Eagle 1000 Series Stretch Wrapper

Operations Manual Eagle 1000 Series Stretch Wrapper Operations Manual Eagle 1000 Series Stretch Wrapper Models A & B - 1 - READ ALL INSTRUCTIONS CONTAINED IN THIS MANUAL PRIOR TO MACHINE INSTALLATION! - 2 - Contents page 1. Machine Safety Information 1.1

More information

Transfer Switch TS-50. Owner s Manual

Transfer Switch TS-50. Owner s Manual Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer

More information

ITEM #75618 Sylvania Staylit 7.5 ft. Sherwood Pine Pre-lit Tree MODEL #V

ITEM #75618 Sylvania Staylit 7.5 ft. Sherwood Pine Pre-lit Tree MODEL #V Holiday Living is a registered trademark of LF, LLC. All Rights Reserved. ITM #7568 Sylvania Staylit 7.5 ft. Sherwood Pine Pre-lit Tree MODL #V672-67 PACKAG CONTNTS Part A B C D F Description Top tree

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS AQUALUMINATOR & AQL LIGHT AND RETURN WATER FLOW FOR ABOVE GROUND SWIMMING POOLS INSTALLATION AND USER'S GUIDE Contents SECTION I. IMPORTANT SAFETY INSTRUCTIONS... 2 SECTION II. LAMP HOUSING INSTALLATION...

More information

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.

More information

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL Model Number: Service: Serial Number: Installation Date: Installation Location / Application: PLEASE RECORD THE FOLLOWING DATA (Information is

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

Validator and Control Board Update Instructions for BC1

Validator and Control Board Update Instructions for BC1 Validator and Control Board Update Instructions for BC1 Installation Overview The update kit for the Rowe BC1 enables the changer to interface with a Mars AE/VN 120-volt validator. The validator determines

More information

Installing the Switch Chassis

Installing the Switch Chassis Safety, page 1 Installation Options with Racks and Cabinets, page 2 Airflow Considerations, page 2 Installation Guidelines, page 2 Unpacking and Inspecting the Switch, page 3 Installing the Switch, page

More information

SBP2 Pendant Pushbutton Stations Installation Instructions

SBP2 Pendant Pushbutton Stations Installation Instructions SBP2 Pendant Pushbutton Stations Installation Instructions P.O. Box 13615 Milwaukee, WI 53213-3615 Phone: 262-783-3500 Fax: 262-783-3510 Toll free Phone (in USA): 800-288-8178 Toll free Fax (in USA): 800-298-3503

More information

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL: SERIAL NUMBER: DATE PURCHASED:

More information

To Purchase This Item, Visit BMI Gaming

To Purchase This Item, Visit BMI Gaming Table of Contents General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options... 4-6 Troubleshooting Guide. 7-8 Parts Identification 9 Schematics 10-13

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information