1 KYN28-12 Series H.V Metal Clad Switchgear Product Specification 10/08/2015 Electrical Treasure One-Stop Supplier Of Electrical Equipment 1

2 KYN28-12 Series With Prevent Wrong Operation Of Metal Clad Switchgear No Maintenance Medium Voltage Switchgear 1. Summarize What is electrical switchgear? KYN28-12 Metal Clad Switchgear, rated medium voltage 3.6 kv ~ 12 kv three phase AC 50 (60)Hz, with high breaking capacity and low values of intercepting the VS1 type (or ABB VD4 type ) vacuum circuit breaker. electrical Electrical Treasure One-Stop Supplier Of Electrical Equipment 2

3 switch definition, vacuum circuit breaker as the main switchgear. KYN28-12 Series Metal Clad Switchgear, the power generation, transmission, distribution, conversion and energy consumption of On /Off, control & protection of the important high voltage switchgear. Widely Used: What is a switchgear? KYN28-12 Metal Clad Switchgear, receiving and distribution of electrical energy and the circuit for control, protection and detection, suitable for single busbar, single bus section system or double busbar system, metal enclosed switchgear widely used in electric power system of electrical substation, power plants, Industrial building and construction projects for high voltage electric distribution & switchgear solutions. Advanced Structure: KYN28-12 Metal Clad Switchgear, medium voltage switchgear components of Cabinet Body and handcart. Cabinet Body by metal clapboard separates into 4 separate partition room: bus room, circuit breaker handcart room, cable room and relay control &instrument room. Metal Clad Switchgear of Vacuum circuit breaker for the Middle Position Type (circuit breaker, which is situated in the middle of Electrical Treasure One-Stop Supplier Of Electrical Equipment 3

4 the switchgear cabinet before), the expansion of the lower space savings can be used for other options or cable room. High Security: KYN28-12 Metal Clad Switchgear, used electrical switchgear easy, safe and reliable interlocking device: to prevent wrong operation circuit breaker, prevent loading and isolating switch, prevent charged hang ground wire, which prevent electric grounding switch, prevent with ground wire transmission. in switchgear medium voltage, includes high voltage circuit breaker, grounding switch, mutual inductor, microcomputer protection device, etc. KYN28-12 Metal Clad Switchgear meet IEC298, IEC694 standards. 2. Types Of Meaning Electrical Treasure One-Stop Supplier Of Electrical Equipment 4

5 3. Regular Service Condition Surrounding Air Temperature The Highest Temperature + 40, The Lowest Temperature -15 Daily Average Relative Humidity 95% Low Humidity Conditions The Average Daily Water Vapor Pressure is Less Than 2.2 kpa Monthly Average Relative Humidity 90% On Average Water Vapor Pressure is Not More Than 1.8 kpa Low Altitude 3000 m and Below; 3000 m Low Seismic Intensity No More Than 8 degrees; Low Ambient Air Shall Be Subjected To Corrosive or Flammable Gas, Water Vapor and Other Obvious Pollution Low Without Frequent Severe Vibration Place Low Beyond The Normal Environment Conditions In The Regulations When Used By Users and Manufacturers To Negotiate 4. Main Technical Parameters Item Description Unit Data Rated Voltage KV 3.6 6,7.2,10,11,12 Rated Power Hz 50(60) Circuit Breaker Rated A Current Rated Current Switch A Devices Rated Short-Time Resistance Current (4 s) ka Rated Short Circuit Breaking Current ka Rated Short Circuit Close Current (Peak Value) Rated Insulation Level Protection Grade 1 min Frequency Withstand Voltage ka Electrode Spacing,Phase Lightning Impulse Withstand ka Grounding Spacing Voltage (Peak Value) Between The Fracture kv Electrode Spacing,Phase Grounding Spacing kv Between The Fracture kv Cabinet Body IP4X Isolation, Circuit Breaker Room Door is Opened IP2X Electrical Treasure One-Stop Supplier Of Electrical Equipment 5

6 5. Structural Features Fully metal armor, modular structure, combination scheme is extensive. Cabinet put oneself in another's position chooses import apply aluminium zinc steel plate, the CNC machine tool processing. USES the advanced multiple flanging process, with the pull rivet nut, high strength bolt connection, and the precision is high, corrosion resistance, light weight, high strength, strong parts universal. Can be equipped with VS1 series or VD4 vacuum circuit breaker, wide applicability, high reliability, realize years free maintenance. Handcart, experimental position, the position has the positioning and display device, safe and reliable. All kinds of hand press modulus modular change, guarantee the handcart free swap with specifications, different specifications handcart absolutely cannot enter. Comprise by special delivery of handcart, lightweight, flexible operation. Cable room can be installed up to 9 single core cable; Highly reliable interlock, fully meet the requirements of "five Electrical Treasure One-Stop Supplier Of Electrical Equipment 6

7 prevention". The high pressure chamber are relief channel, ensure the personal safety. The front door is equipped with observation window, can observe indoor components working condition. 6. External Dimension Height B 2300(2200)(mm) Small Branch Busbar Rated Current Of 1250 A The Thermal Width A Stability Of Current 40 KA 800(mm) More Than 1600 A Small Branch Busbar Current Rating 1000(mm) Depth C Outlet and Inlet Line Of Cable 1500(mm) Outlet and Inlet Line Of Overhead 1660(mm) Weight Including Vacuum Circuit Breaker Switchgear (kg) Electrical Treasure One-Stop Supplier Of Electrical Equipment 7

8 7. Main Technical Data 7.1 (VS1 Type) Vacuum Circuit Breaker Technology Parameters No. Items Unit Data 1 Rated Voltage KV 12 2 Maximum Working Voltage KV 12 3 Rated Current A Rated Short Open Circuit Current KA Rated Short circuit Close Current KA Rated Front Value Tolerance Current KA s Rated Short Circuit Resistance Current KA Power Frequency Withstand 8 Rated Insulation Level Voltage (Rated Before and After Breaking) Impact Pressure (Rated Before and After Breaking) KV 42(Fracture18) 75(Fracture84) 9 Rated Operating Sequence open-0.3s-close/open-180s-close/open 10 Mechanical Life time Rated Short Open Circuit Current Switching Frequency Hz 50(60) Operation Mechanism Rated Switching Voltage (dc) Operation Mechanism Rated Points Gate Voltage (DC) V 110,220 V 110, Contact Open Distance mm 11±1 15 Super Stroke (Contact Spring Compression Length) mm 3.5± Three-Phase Points Switching ms 2 17 Contact Switching Bounce Time ms 2 18 Average Brake Speed m/s 0.9~ Average Closing Speed m/s 0.5~0.8 Electrical Treasure One-Stop Supplier Of Electrical Equipment 8

9 20 Points Brake Highest Operating Voltage s 0.05 Time Minimum Operating Voltage Closing Time s Each Phase Main Loop Resistance u Ω Action Contact Allowed To Wear Cumulative Thickness mm Voltage Transformer Technical Parameters Type Rated Voltage (kv) Rated Capacity At Each Level(VA) 0.5 Level 1 Level 3 Level JDZ-3 3/0.1 JDZJ JDZ-6 6/ JDZJ JDZ-10 10/0.1 JDZJ Electrical Treasure One-Stop Supplier Of Electrical Equipment 9

10 7.3 (LZZBJ9-10 Type)Current Transformer Parameters Rated Primary Current Accurate Level Combination Rated Secondary Output 0.2S 0.5S 10P10 Thermal Stability Current Dynamic Stability Current s/10P s/10P (VS1 Type) Electric Operating Mechanism Parameters Rated Voltage & Type(V) Rated Input Power (W) Rated Time For Emerge Storage (S) Service Voltage Range %-110%Ue Switch-On Electromagnet Voltage & Current Alternating Current Direct Current Rated Voltage(V) Rated Current(A) Service Voltage Range 85%~110%Ue Switch-Off Electromagnet Voltage & Current Alternating Current Direct Current Rated Voltage(V) Rated Current(A) Service Voltage Range 65%~120%Ue Electrical Treasure One-Stop Supplier Of Electrical Equipment 10

11 7.5 (RN1 Type) Fuse Technical Parameters Type RN1-6 RN1-10 Rated Voltage (kv) 6 10 Max Breaking Current Effective (Ka) Rated Current (A) 20 Rated Current For Fuse(A) 2,3,5,7.5,10,15,20 Current Limiting Peak For Breaking Limiting Short Scirait Current RN2 Type Fuse Technical Parameters Type Rated Voltage (kv) RN2-6 6 RN Rated Current(A) Rated Breaking Capacity MVA Fuse Pipe Resistance(Ω) Zinc-Oxide Arrester (Silicone Rubber Gapless) Parameters Type (HY5WS) 10/30 17/50 10/30 17/45 10/27 10/45 System Rated Voltage(Kv) Arrester Rated Voltage(kV) Continual Service Voltage(kv) Reference Voltage DC 1mA (kv) Rating Discharge Current(Ka) Residual Voltage Under Lighting Impulse Current ( Kv) Residual Voltage Under Steep Current Impulse ( Kv) Residual Voltage Under Operating Impulse Current ( Kv) / / Electrical Treasure One-Stop Supplier Of Electrical Equipment 11

12 Discharge Capacity For ZMS Square Impulse (A) Note Discharge Station 8. Interpretive Structural Switch equipment designed standard armoured metal-enclosed switchgear. KYN28-12 Series H.V Metal Clad Switchgear by fixed cabinet body and handcart, composed of two parts. cabinet body shell and the separator adopts bolt coupling of each function unit. Switchgear enclosure protection grade is IP4X, circuit breaker room door is opened, the protective class is IP2X. Can with the vacuum circuit breaker handcart Switchgear, can also be used with fixed load switch. With overhead into (out of) line, cable wire and other functions. Switchgear can be installed into a double tank arrangement, Electrical Treasure One-Stop Supplier Of Electrical Equipment 12

13 that is, installation into a back to back or face to face double row arrangement (see figure 6, 7) FIG 6 Double Bus (back to back) Solution &Switchgear Schematic FIG 7 Double Bus (Face-to-Face) Solution &Switchgear Schematic 8.1 Shell and Partition KYN28-12 Series H.V Metal Clad Switchgear shell and baffle plate is made by aluminium zinc steel plate, the CNC machine tool processing, and adopts the multiple folding process, the Electrical Treasure One-Stop Supplier Of Electrical Equipment 13

14 whole cabinet body not only has high precision, strong resistance to corrosion and oxidation resistance. Due to adopting multiple flanging process, make the cabinet body than other similar equipment cabinet body, light weight, high mechanical strength as a whole. Cabinet body adopts modular structure, with the pull rivet nuts and high strength bolt connection and into. Short production cycle, parts versatility, covers an area of less, easy to organize production. Switchgear is separated into handcart room, bus room, cable room, relay instrument room (low voltage room), every outdoor insulation shell are independent grounding. Switchgear door use spraying plastics coating process, make its surface impact resistant, corrosion resistant, guarantees the appearance is beautiful 8.2 Handcart Handcart skeleton, uses the steel plate, riveting after processed by CNC machine tool. Handcart and Cabinet body insulation coordination, mechanical interlocking, safe, reliable and flexible. According to the purpose, handcart can be divided into the Electrical Treasure One-Stop Supplier Of Electrical Equipment 14

15 circuit breaker handcart, voltage transformer handcart, metering handcart, and so on. All kinds of height and depth of the handcart is unified, the same specifications of the handcart can swap. Handcart in the Cabinet body with isolation/test position and work location, each place has positioning device, to ensure reliable interlocking, should be performed according to interlocks prevent wrong operation procedure. All handcart adopt rock propulsion, exit the nut, screw, its lightweight, flexible operation, suitable for the personnel on duty operation. Handcart when you need to remove the Cabinet body, with a special transport vehicles, can be pulled out, for all kinds of inspection, maintenance; Use intermediate implantation, the handcart is small in size, inspection, maintenance is extremely convenient. 8.3 Switchgear Inside the Compartment KYN28-12 Series H.V Metal Clad Switchgear of the main electrical components have their separate compartment, circuit Electrical Treasure One-Stop Supplier Of Electrical Equipment 15

16 breaker room handcart room, bus room, cable room, relay instrument room. Each compartment protection grade achieved IP2X; In addition to relay outside, other three compartment respectively have its drain voltage channel. Adopted the intermediate implantation, cable room position has greatly increased, so the device can connect multiple cable Circuit Breaker Room In the circuit breaker room installed for circuit breaker handcart sliding guide rail. Handcart can work in the location, test/isolation between mobile. Activity curtain plate made of metal plate installed after the handcart room wall. Handcart from isolation in mobile to work location/test position, in a small busbar room and cable connection chamber (cable room) in the static contact box on the static contact of the activity curtain plate automatically open. Reverse direction handcart, activity curtain plate automatic closing, closed up and the static contact case, so as to guarantee the operators do not touch the charged body. Electrical Treasure One-Stop Supplier Of Electrical Equipment 16

17 Handcart in the switchgear door closed cases by operation, through the observation window you can see the handcart inside ark's position. At the same time also can see the hand car On (to make the circuit breaker closing)/off (to make the circuit breaker break-brake) buttons and On/OFF mechanical position indicator and energy storage/release status indicator Draw Out Type Circuit Breaker Handcar Frame is welded by steel plate, hand car equipped with vacuum circuit breaker and other auxiliary equipment. A dynamic contact with spring contacts subsystem, the arm in a circuit breaker on the outlet terminals, circuit breaker operating mechanism of the control button and on/off instructions, etc., are in the handcart panel, with convenient operation. Handcart into the Switchgear arrived at isolation/test position, the handcart shell and reliable connected switchgear earthing system, instrument protection and control circuit are also Electrical Treasure One-Stop Supplier Of Electrical Equipment 17

18 through secondary switchgear and plug for connection Bus Compartment Room Bus bar from one switchgear to the other switchgear, through the branch busbar and static contact box fixed. Lady rounded copper platoon of contact line and bus bar with rectangular cross section. Used for high current load need to use two rectangle busbar. All bus bar with heat shrinkable casing cover. Flat branch line by bolt connection with static contact box of mistress line connected. Bus through the Switchgear supported by insulating sleeve plate, if internal arc fault line inside ark, can prevent bus through melting, guarantee the accident does not spread to the adjacent tank, and avoid mistress line deformation due to the effect of electric power Cable Compartment Room Cable compartment room back wall, can be installed current transformer, voltage transformer, grounding switch, cable room also can install lightning arrester. After handcart and horizontal clapboard move, construction personnel could enter a Switchgear installed cable from the Electrical Treasure One-Stop Supplier Of Electrical Equipment 18

19 front. Has specific cable connection in indoor cable conductor, and 1-6 single core cable, at the same time in the lower part of the preparation of removable metal plate, to ensure that the site construction convenience Instrument Compartment Instrument interior insulation can be installed relay protection equipment, instruments, electrical monitoring indicator and special requirements of secondary equipment. Control circuit laying within the enough space of the trough, and the metal plate. On the left side of the trough is reserved for the control of small bus introduction and raises, secondary line Switchgear equipped on the right. There were small instrument compartment on the side panel of bus bar through the hole to construction. 8.4 Prevent Wrong Operation Interlock Switchgear has reliable interlocking device for operating and maintenance personnel to provide reliable safety protection, its action is as follows: Handcart from work position to the isolation/test position, Electrical Treasure One-Stop Supplier Of Electrical Equipment 19

20 activity curtain board to separate the static contact box, prevent into charged across the room. Overhaul, the available padlock lock activity curtain plate. The circuit breaker is in a state ON, handcart cannot be pulled out from the work position or push isolation/test position to work location. Circuit breaker handcart has fully lock test position or work position can be operation Grounding switch only in handcart in isolation/test position and to be operating outside the tank, when the earthing switch is in a state ON, handcart can't work from isolation/test location to location. Handcart in the work position, the second plug is locked can not pull to open 8.5 Pressure Relief Devices In the handcart room, busbar room and cable room above, are equipped with pressure relief devices. When a circuit breaker or bus internal arc fault occurs, along with the emergence of the arc, higher air pressure inside the Switchgear, the top pressure relief plate assembly will be automatically open. Electrical Treasure One-Stop Supplier Of Electrical Equipment 20

21 Release pressure and discharge gas, to ensure the safety of operators and switchgear. 8.6 Second Plug and The Location Of Handcart Interlock Second line in the Switchgear and the handcart secondary line of contact is done by a second plug. Secondary dynamic contact plug through a nylon corrugated pipe is connected to a handcart, secondary static contactor seat installed in the top right switchgear breaker compartment. Handcart only in the test/isolation position, can plug in and remove the second plug, handcart in working position in mechanical interlock function, quadratic plug is locked, can't remove. Circuit breaker handcart in secondary can only before the plug is not connected to brake, as a result of the circuit breaker handcart switch mechanism by electromagnetic lock, so I can't make its closing. 8.7 Charged Display Device Switchgear with charged display device. The device is composed of high voltage sensors and portable display of two parts. Electrical Treasure One-Stop Supplier Of Electrical Equipment 21

22 Sensors installed in bus or feeder side, the monitor interface is installed on the low voltage switchgear isolation room, need to be detected when A, B, C three-phase is charged, can insert the plug of the portable display L1, L2, L3 interfaces, if the display action, says bus or feeder side charged, on the other hand, shows no charge. At the same time also can be used as phase sequence detector or lightning indicator, its effect also is testing whether charged on the high side 8.8 Prevent Condensation and Corrosion In order to prevent the high humidity or temperature change the larger environment, climate produce condensation of danger. In the circuit breaker room and cable room installed heater respectively, in order to use in the environment and prevent the corrosion. 8.9 Grounding Device In the cable room separate 5 x 40mm ² was grounding copper platoon, by the adjacent Switchgear, and with the cabinet body good contact. Grounding for the use of direct grounding of the components. Cabinet body with aluminized zinc plate split, so that the whole Electrical Treasure One-Stop Supplier Of Electrical Equipment 22

23 cabinet body was in good grounding, ensuring the safety of operating personnel and cabinet body.. 9. Install and Use For Details, Please Refer to SZET Co., LTD <Installation and Maintenance Manual> Electrical Treasure One-Stop Supplier Of Electrical Equipment Electrical Treasure One-Stop Supplier Of Electrical Equipment 23

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal Enclosed Switch 1.General KYN28-12 armoured middle-mounted metal enclosed switchgear (hereinafter referred to as switchgear) is a new product with own design

More information

Instruction for Installation and Operation

Instruction for Installation and Operation KYN79 (i-ax) Metalclad Removable AC Metal-Enclosed Switchgear Instruction for Installation and Operation K 15 24 SM 01 02 Tianshui Changcheng Switchgear Factory January, 2007 Warning: This instruction

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work GE Consumer & Industrial Power Protection New SecoGear 12-24kV GE imagination at work General SecoGear metal-clad switchgear is designed and manufactured with advance technology and has been comprehensively

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv 06B1-E-0002 Small Space Requirement, High Reliability and Safety ー 72.5 to 145 kv GIS, SDH314/SDHa314

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

MCSG 12kV / A

MCSG 12kV / A MCSG 12kV / 630-5000A Air-insulated Metal-clad Withdrawable Switchgear A D B C W METAL CLAD 1 INDEX 1. Summary.4 1.1 General 4 1.2 Service Conditions 4 1.2.1 Normal Operating Conditions 1.2.2 Special Operating

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment General The switchgear must be suitable for 36 kv rated voltage and specifically conceived for the secondary distribution substations in M.V. with either ring or radial type networks. The switchgear must

More information

8DJ. Maintenance-free for lifetime

8DJ. Maintenance-free for lifetime 8DJ Maintenance-free for lifetime Energy Distribution Welcome! Page 2 October 1 st 2008 8DJ Main Applications for Medium-Voltage Switchgear Power generation Power stations G Power transmission High and

More information

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear. Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical

More information

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A. SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation 630 3150A SYSclad 12 17,5kV 16 31,5kA Generalities SYSclad is a medium voltage switchboard metal clad

More information

MESG 12 / 17.5 / 24 / 36 KV

MESG 12 / 17.5 / 24 / 36 KV MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL

More information

Metal Clad Air Insulated Switchgear

Metal Clad Air Insulated Switchgear Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system

More information

Extensible Unit - VCE2a

Extensible Unit - VCE2a ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre) Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel: ELECTRICAL INDUSTRIAL COMPANY

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

Benefits, typical uses

Benefits, typical uses R-HA26-013. eps Switchgear Type 8BT1, up to 24kV,Air-Insulated Contents Application Page Application Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, 5 room planning

More information

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES Description JRS arc-resistant fused/non-fused load break and fused/non-fused disconnect switches are available for applications

More information

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Switchgear Type 8BT1, up to 24 kv, air-insulated.   Medium Voltage Switchgear Catalog HA 26. www.siemens.com/medium-voltage-switchgear Switchgear Type 8BT1, up to 24 kv, air-insulated Medium Voltage Switchgear Catalog HA 26.31 2012 Answers for infrastructure and cities. R-HA26-013. eps Contents

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,

More information

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection

More information

WOLUN. ZN63A-12 (VS1) Type. ZN63A-12 (VS1) Type Indoor High Voltage Vacuum Circuit Breaker. General Introduction. Technical Specification

WOLUN. ZN63A-12 (VS1) Type. ZN63A-12 (VS1) Type Indoor High Voltage Vacuum Circuit Breaker. General Introduction. Technical Specification ZN- (V1) Type ZN- (V1) Type ZN- (V1) type indoor high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is used for indoor high voltage switch equipment of power system, as a

More information

Metal Clad Switchgears

Metal Clad Switchgears SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,

More information

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv] BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9 Content 1. Design philosophy... 3 2. Applications... 5 3. Switchgear construction... 6 4. Cubicle types... 9 4.1 Cubicle program... 9 4.2 Cubicle type SDC... 11 4.3 Cubicle with fuse, type SDF...12 4.4

More information

40.5kV ET2 Removable AC Metal-enclosed Switchgear

40.5kV ET2 Removable AC Metal-enclosed Switchgear 4.5kV ET2 Removable AC Metal-enclosed Switchgear Automotive Powering business worldwide Aerospace Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing

More information

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast. ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW High performance alternative to air

More information

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities. www.siemens.com.cn/medium-voltage-switchgear Air Insulated Switchgear NXAirS, Answers for infrastructure and cities. Applications Page Application Type 2 Typical uses 3 Classification 3 Type NXAirS withdrawable

More information

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) About company The «Elektroapparat» plant starts its operation in 1922 as a plant manufacturing high-voltage electrical equipment. During the first two

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and

More information

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1. DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for

More information

Modular medium-voltage switchgear. NorMax

Modular medium-voltage switchgear. NorMax Modular medium-voltage switchgear NorMax NorMax MODULAR MEDIUM-VOLTAGE SWITCHGEAR 2 NorMax Modular medium-voltage switchgear Contents Subject Page Table of contents 2 Introduction and main features 2 Technical

More information

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

Gas Insulated Switchgear

Gas Insulated Switchgear Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com TGOOD produces over 5000 switchgear units annually for projects around the globe SOLUTION OVERVIEW For use in affordable air insulated

More information

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A) M6 24kV Medium Voltage Switchgear MetalEnclosed (LSC2A) GENERAL FEATURES GENERAL DESCRIPTION The structure of the cubicles, of considerable strength, has selfsupporting structure and is made of steel sheet

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka ATR-MIX METAL ENCLOSED SWITCHGEAR 12-24-36kV 630-1250 A 16-20-25 ka INDICE 01 GENERAL DESCRIPTION TECHNICAL DATA UNIT TYPES TYPICAL UNITS - ATR 01 TYPICAL UNITS - ATR 02 TYPICAL UNITS - ATR 03 TYPICAL

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls 11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the

More information

ZX2 Gas-insulated medium voltage switchgear

ZX2 Gas-insulated medium voltage switchgear Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters

More information

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS) Compact Gas Insulated Switchgear (GIS) up to 45 6,45 Compact Gas Insulated Switchgear (GIS). Standard: IEC 6703. Typical Feature. Great Breaking Character of Circuit Breaker The circuit breaker adopt the

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal

More information

ZX2.2 Gas-insulated medium voltage switchgear

ZX2.2 Gas-insulated medium voltage switchgear ZX2.2 Gas-insulated medium voltage switchgear 2 Brochure ZX2.2 Power engineering from ABB Solutions for the future As a technology group with global operations, ABB supplies the solutions of the future

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

the safe, reliable, and efficient choice for MV switchgear

the safe, reliable, and efficient choice for MV switchgear Power Xpert UX IEC Medium Voltage switchgear Tested to IEC 62271-200 17.5 kv up to 50 ka - 3 s 24 k V up to 25 ka - 3 s Air insulated switchgear Internal arc classified LSC2B-PM UX the safe, reliable,

More information

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS PROTECTION AGAINST INTERNAL ARCS TYPICAL UNITS 3 Characteristics

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT SWITCHCRAFT Switchcraft Europe GmbH Switchgear Product Overview igis Gas Insulated Switchgear isis Solid Insulated Switchgear icb - Vacuum Circuit Breaker iair - Air insulated switchgear panel Switchcraft

More information

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear Catalog HA 40.2 2009 Answers for energy. -HA40-111.eps -HA40-110.eps -HA40-109.eps -HA40-112.eps

More information

Switchgear Type 8DJH 36 for Secondary

Switchgear Type 8DJH 36 for Secondary Catalog HA 40.3 Edition 2017 Switchgear Type 8DJH 36 for Secondary Distribution Systems up to 36 kv, Gas-Insulated Medium-Voltage Switchgear siemens.com/8djh36 Application Typical uses R-HA40-135.tif R_HA40-150a

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

Medium voltage vacuum circuit breaker. E-VAC series

Medium voltage vacuum circuit breaker. E-VAC series Medium voltage vacuum circuit breaker E-VAC series Product description E-VAC vacuum circuit breaker Contents Description Product description... Technical data... Dimensions... Wiring diagram... E-VAC series

More information

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear 2018 MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Non-arc-resistant MV ANSI switchgear Agenda Ratings, dimensions and qualifications MV ANSI circuit breakers for Design features Auxiliary compartments Enclosures

More information

24kV ET1 Removable AC Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker

24kV ET1 Removable AC Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker 24 ET1 Removable C Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker utomotive Powering business worldwide erospace Eaton delivers the power inside hundreds of products that

More information

Vacuum Circuit Breaker

Vacuum Circuit Breaker Vacuum Circuit Breaker 12/24kV VECTOR series Vacuum Circuit Breaker VMS series Metal-clad Switchgear Medium Voltage Systems 003 FM 73638 12/24kV VECTOR VCB Features of the VECTOR Vacuum Circuit Breaker:

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

Removable AC Metal-enclosed Switchgear

Removable AC Metal-enclosed Switchgear Removable AC Metal-enclosed Switchgear 2kV ET Automotive Powering business worldwide Aerospace Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing

More information

Power IT Air Insulated Cubicle Uniswitch

Power IT Air Insulated Cubicle Uniswitch - 1-4/2/2003 Secondary Distribution Switchgear Power IT Air Insulated Cubicle Uniswitch Table of Contents Market segment Ratings New for 2003 Technical features Advantages Market segment Uniswitch Switchgear

More information

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel We engineer, we assure. EMC 24 SERIES METAL CLAD SWITCHGEAR Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel Saudi Cable Company REF: EMC24-EN-16-04 2 www.elimsan.com

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance M E T A L - C L A D S W I T C H G E A R Safe and Reliable Flexible, Compact Design Easy Installation and Maintenance We build a better future! Hyundai HMS medium-voltage metal-clad switchgears and control-gears,

More information

33KV INDOOR SWITCHGEAR

33KV INDOOR SWITCHGEAR 33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated www.siemens.com/medium-voltage-switchgear Fixed-Mounted Circuit-Breaker Switchgear Type 8D and 8DB up to 0.5 kv, Gas-Insulated Medium-Voltage Switchgear Catalog H 35.11 201 nswers for infrastructure and

More information

UniGear. Technical Guide

UniGear. Technical Guide UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating

More information

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR CONTENT EPE METLCLD SWITCHGERS SERIES EPE 1220 / - 12KV METLCLD SWITCHGER EPE 10D - 12KV METLCLD SWITCHGER EPE 24-24KV METLCLD SWITCHGER EPE 36-36KV METLCLD SWITCHGER EPE METLCLD SWITCHGERS MS SERIES 12

More information

12kV xdl Removable AC Metal-enclosed Switchgear

12kV xdl Removable AC Metal-enclosed Switchgear kv xdl Removable AC Metal-enclosed Switchgear Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

Zinc-Oxide Surge Arrester TEXLIM Q-C

Zinc-Oxide Surge Arrester TEXLIM Q-C Zinc-Oxide Surge Arrester TEXLIM Q-C Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. in areas with very high lightning intensity where

More information

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Issue 3 2012 SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) www.energynetworks.org 2012 Energy Networks

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

ZX-Family Gas-insulated medium voltage switchgear

ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom

More information

medium voltage switchgear manufacturer VACUUM CIRCUIT-BREAKER SWITCHGEAR TYPE SIMOPRIME, UP TO 17.5kV, AIR INSULATED MEDIUM-VOLTAGE SWITCHGEAR. UNDER LICENSE BY SIEMENS. www.simosynergy.com/simoprime VACUUM

More information

Low Voltage Main Distribution Board

Low Voltage Main Distribution Board s M series... Low Voltage Main Distribution Board Safe and intelligent power distribution Whether in industrial plants, in infrastructure or in buildings, all technical plant depends on the reliable supply

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

Valid for you. medium voltage switchgear

Valid for you. medium voltage switchgear Valid for you. medium voltage switchgear VEO knows your needs VEO s field of expertise is energy. We provide customised automation and electrification solutions for customers in the power generation, distribution

More information

Zinc Oxide Surge Arrester EXLIM R

Zinc Oxide Surge Arrester EXLIM R Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy

More information

ASN3 ASN2 ASN1. ASN Series Medium voltage, metal-clad, air-insulated switchgear for primary distribution

ASN3 ASN2 ASN1. ASN Series Medium voltage, metal-clad, air-insulated switchgear for primary distribution ASN3 ASN2 ASN1 ASN Series Medium voltage, metal-clad, air-insulated switchgear for primary distribution ASN Series - The Next-Generation MV Switchgears About The Product The ASN series switchgear is Cooper

More information

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35. Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to kv, SF 6 -Insulated Medium-Voltage Switchgear Catalog HA 5. 00 Invalid: Catalog HA 5. 00 R-HA5-05 eps Fixed-Mounted Circuit-Breaker Switchgear

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear Catalog HA 40.2 2010 Answers for energy. -HA40-110.eps -HA40-109.eps -HA40-112.eps -HA40-111.eps

More information

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples. Transportation and storage.. 3 General. 3 Unpacking at installation site....... 3 Transfer of cubicles at installation site... 3 Weight.. 4 Temporary storage. 4 Erection at site 5 General. 5 The switchgear

More information

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear Descriptive bulletin ReliaGear ND ANSI narrow frame metal-clad switchgear Table of contents Introduction...3 Vmax/A breaker...4 Instrument transformers...5 Potential transformers...6 15 kv potential transformers...6

More information

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Catalog HA 40.2 Edition 2017 Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear siemens.com/8djh Application Typical uses R-HA40-111.tif R-HA40-112.tif