AIR CURTAIN HX RECESSED RANGE

Size: px
Start display at page:

Download "AIR CURTAIN HX RECESSED RANGE"

Transcription

1 AIR CURTAIN HX RCSSD RANG INSTALLATION, OPRATION AND MAINTNANC INSTRUCTIONS N. America nglish Page

2 CONTNTS CONTNTS... LCTRICAL SAFTY... SPCIFICATIONS.... INTRODUCTION.... DLIVRY CONTNTS.... TOOLS RQUIRD INSTALLATION RMOT CONTROL INSTALLATION RMOT CONTROL STTINGS XTRNAL CONTROLS SYSTM CONFIGURATION.... MULTIPL AIR CURTAINS.... FAN SPD SLCTION.... RMOT CONTROL OPRATION.... COMMISSIONING TH SYSTM.... SIGN OFF FAULT CONDITIONS SRVIC & MAINTNANC WARRANTY... 8 APPNDIX DIMNSIONS OF HX RCSSD AIR CURTAIN... 9 APPNDIX A WIRING DIAGRAM HX000R 08V... 0 APPNDIX B WIRING DIAGRAM HX00R 08V... APPNDIX C WIRING DIAGRAM HX000R 08V... APPNDIX D WIRING DIAGRAM HX000R 80V or 00V... 0 APPNDIX WIRING DIAGRAM HX00R 80V or 00V... APPNDIX F WIRING DIAGRAM HX000R 80V or 00V... APPNDIX G WIRING DIAGRAM HX000WR, HX00WR and HX000WR... APPNDIX H WIRING DIAGRAM HX000AR, HX00AR and HX000AR Page

3 LCTRICAL SAFTY lectrical Supply and Wiring to the Air Curtain All electrical wiring and connections MUST be carried out by a competent qualified electrician in accordance with the latest edition of the I wiring regulations and/or local statutory regulations. A phase or phase local disconnect having a contact separation of at least mm on all poles must be fitted in the electrical supply to the air curtain and located in an accessible position adjacent to the unit. Units with dual electrical supplies (see * in Table below) must have a common disconnect to switch off both supplies simultaneously. The appliance must be connected by cables having an appropriate heat resistant temperature rating. All supply cables, circuit breakers and other electrical installation equipment must be correctly sized for the air curtain model being installed; see section : Specifications. Models operating on a 80V or 00V, phase electrical supply - see section : Specifications, lectrical Supply * also need a separate 08V to 0V electrical supply to operate fan motors and controls. A mm / in size cable gland or conduit connector should be used for the lectrical Supply into the air curtain. The air curtain must be grounded. SPCIFICATIONS Air Curtain Model lectrical Supply (V/ph/Hz) Rated lectrical Power Input (kw) Rated Current per phase (A) Heat Output [Low/High] (kw) ffective Width of Airstream (m / in) Weight (kg / lbs) HX000AR 08 0// / / 99 HX00AR 08 0// / / HX000AR 08 0// / 8 80 / 7 HX000WR 08 0//0 0.. /.0 / / HX00WR 08 0// /8. / 7 / HX000WR 08 0// /. / 8 9 / 0 HX000R (08V) 08//0..0 /.0 / / 0 HX00R (08V) 08// /8. / 7 / 8 HX000R (08V) 08// /. / 8 8 / 8 HX000R (80V) 80//0* //0 0.. /.0 / / 0 HX00R (80V) 80//0* // /8. / 7 / 8 HX000R (80V) 80//0* // /. / 8 8 / 8 HX000R (00V) 00//0* //0 0.. /.0 / / 0 HX00R (00V) 00//0* 8 7. /8. / 7 / 8 HX000R (00V) //0 00//0* // /. / 8 8 / Page

4 . INTRODUCTION stablished in the 90s, Thermoscreens is a leading air curtain manufacturer that exports to over 0 countries worldwide. As with all our products, the HX range of air curtains is designed with energy efficiency in mind. HX models suffixed R, WR or AR are designed to be recess mounted inside a building and located horizontally over a doorway. They must not be installed on the outside of a building. Please complete the following details for your reference: Date of Purchase Place of Purchase Serial Number Proof of purchase is required to make a claim under warranty. Thermoscreens Canada Toll Free: King Street, Unit # Tel: Barrie, Ontario Fax: Canada LN BS mail: salescanada@thermoscreens.com Page

5 . DLIVRY CONTNTS The following items are supplied in the box at delivery. NOT: If any parts are missing or damaged contact your place of purchase. HX Recessed Air Curtain copower Remote Control Note: The recessed grille is packed separately. Supplied with m / 0ft control cable Outdoor Air Sensor (Optional) Available for weather compensation control. TOOLS RQUIRD The following tools are required for installation: Flat head screwdrivers Phillips head screwdrivers 0mm wrench Adjustable wrench lectric drill Ladders Appropriate lifting equipment Appropriate tools for cutting ceiling aperture Page

6 7. INSTALLATION The air curtain is designed to be recessed within ceiling voids or bulkheads within a building and located horizontally over a doorway. It must not be installed outside of the building. 7. Location Mount the air curtain above and as close to the doorway as possible, with: the recessed grille not more than.m / ft in above floor level the air discharge (see, Fig ) section of the recessed grille nearest the doorway and the air inlet section (see, Fig ) furthest from the doorway Beware of doorway top edges, structural beams, door opening/closure devices, etc., which may interfere with the air stream and affect the location of the unit. Fig NOT: For the air curtain to work well the doorway should be less than the width of the airstream. 7. Ceiling Suspension Step Cut an aperture in the ceiling to the dimensions in Appendix. Cut notches, if necessary, to clear screws in the air curtain casing. NOT: For LPHW models, pipework will need to be installed above the curtain. Allow sufficient access and height clearance within the ceiling void to do this. Fig Step Fix M0 / /8 UNC threaded rods (not supplied) through the holes at each end in the top casing (see Fig ). Feed the rods through the casing and attach to fixing brackets near the bottom of the unit (see Fig, looking up into the air curtain). Use M0 / /8 UNC lock-nuts either side of the fixing bracket to secure the hanging rod. NOT: Do not let these four hanging rods come below the bottom of the unit casing or they may prevent the recessed grille fitting properly. Fig Page

7 Step If you are installing model HX00R or HX000R, fit a th M0 / /8 UNC threaded rod into the hanging point in the middle of the unit. Refer to Appendix and Fig. M0 / 8" UNC hanging rods Fig RCSSD AIR CURTAIN CILING LVL 8mm /." Bottom surface of recessed air curtain casing 8mm /." CILING LVL Step Secure each rod to a suitable structure that can support the weight of the unit (see section : Specifications for weights). WARNING: It is the sole responsibility of the installer to ensure that the fixing locations and suspension system used are suitable for the air curtain being installed. Step Adjust the height of the unit on its hanging rods so the bottom surface of the casing goes 8mm /.in up into the ceiling as shown in Fig. nsure the unit is level. 7. LPHW Models For LPHW models ensure that water isolation valves are fitted in the flow and return pipework adjacent to the air curtain and connected correctly as shown in the diagram in Appendix. For the design of the water pipework system and pump, water flow rates and pressure drops for maximum heat output of the air curtain are given in the table below. Air Curtain Water Flow Rate (l/min at 8/7 C / US Gall/min at 80/0 F) Water Pressure Drop * (kpa / psi / ft HO) HX000WR, -row (kw). /.. / 0.9 /. HX00WR, -row (8kW). /..9 /.87 /. HX000WR, -row (kw). / 8..9 /. / 7. Air Curtain Water Flow Rate (l/min at 0/0 C / US Gall/min at 0/00 F) Water Pressure Drop * (kpa / psi / ft HO) HX000WR, -row (kw) 8. /. 9. /.8 /. HX00WR, -row (8kW).9 /. 0. /.9 /. HX000WR, -row (kw) 7. /. 0.9 /.8 /. * Water Pressure Drop is across the flow and return connections of the air curtain and includes for the coil and valve fitted inside the unit Page 7

8 7. Attaching the recessed grille to the air curtain The recessed grille consists of: Metal frame Cellular discharge grille Hinged inlet grille There are fixing points on the HX000R, on the HX00R and 7 on the HX000R (see Fig ). Fix the grille as follows: Fig (HX000R shown) Step Open the hinged inlet grille using a flat headed screwdriver to release the quarter turn fasteners (see Fig ). There are two fasteners on the HX000R unit and three fasteners on HX00R and HX000R units. Fig Step Step Make sure the grille will go the correct way around (cellular discharge nearest to doorway). Offer the recessed grille up through the cut-out in the ceiling and attach it to the bottom of the air curtain casing using the Philips head screws supplied. Start with the screws shown in Fig 7 and then fit the two at each end of the discharge grille. If fitting model HX00R or HX000R units insert or screws towards the middle of the unit as shown in Fig 8. Fig 7 Step Step On model HX00R or HX000R units fit screw in the middle of the discharge grille. This screw is easier to access if the hinged inlet grille is temporarily shut. With the hinged inlet grille open again adjust the hanging rods (see Fig 9) so the grille frame fits neatly against the ceiling. nsure the grille frame is a snug fit against the ceiling with no gaps all the way around. Fig 8 Fig 9 NOT: Open the hinged grille core to gain access to electrical connections, and for servicing and maintenance Page 8

9 8. RMOT CONTROL INSTALLATION Mount the remote control unit in a convenient position directly to the wall or onto a switch box. 8. Wall mounting Step Step Step Step Using a screwdriver undo the screw on the top of the remote control case and pull the back case away (see Fig 0). Feed one end of the RJ control cable through the back case, secure it, then screw the back case to the wall using suitable fixings (not supplied). Connect the RJ plug to the RJ socket on the PCB. Refit the front case. Fig 0 8. Switch box mounting Step Step Step Step Using a screwdriver undo the screw on the top of the remote control case and pull the back case away (see Fig 0). Feed one end of the RJ control cable through the switch box, feed and secure the RJ control cable through the back case and secure back case to switch box using x mounting screws (not supplied) (see Fig ). Connect the RJ plug to the RJ socket on the PCB. Refit the front case. Fig / 8 in NOT: For optional remote control settings, see section RMOT CONTROL STTINGS On the back of the remote controller PCB you will find four DIP switches that provide the following optional features. DIP Reset on power-up On restoring power after an electrical interruption all remote control settings are retained. DFAULT STTING ON Dip Stop fan on cold s are switched off when heating level is achieved (Automatic mode only). DFAULT STTING OFF DIP Never blow cold Air curtain always heats in Automatic mode (i.e. will not go to ambient mode). DFAULT STTING OFF DIP Room air temperature control nabling the room air sensor in the remote control disables all other temperature sensors. DFAULT STTING OFF Page 9

10 0. XTRNAL CONTROLS 0. BMS remote on/off To enable the system to be used with a volt free door contact switch or BMS remote switching, an INHIBIT two way screw terminal is fitted on the air curtain motherboard (see, Fig ). To allow the unit to run, use wires to link the terminal to a remote volt free contact. To switch the unit off, leave terminals disconnected (open circuit). Fig In a master/slave arrangement consisting of several air curtains, connect the remote contact to any one of the air curtains. All units will then turn on and off. At factory setting a wire link is fitted to the INHIBIT terminal (see, Fig ). For summer operation connect a.kω resistance across the INHIBIT terminal and only the fans will run, without heat, even if the remote controller is calling for heat. 0. Overheat cut-out indication The air curtain motherboard includes a HALTHY two way screw terminal (see, Fig ) to provide a fault signal indication if the electric heater overheat cut-out operates (electric heated air curtains only). A healthy system provides a V DC signal at the terminals. An overheat cut-out fault will be 0V DC at the terminals. WARNING: Do not apply any other voltage to the INHIBIT and HALTHY terminals as damage to the copower motherboard will occur. 0. Weather compensation For Weather Compensation Heat Control, fit an outside air temperature sensor (Specification - 0k NTC sensing element, time constant minutes and IP protection, or optional Siemens QAC00). Use a -core cable to connect the outdoor air temperature sensor to air curtain terminals and on the connector terminal block on electric heated units (see wiring diagrams, Appendix A, B, C), or terminals and on water heated units (see wiring diagram, Appendix D). Set DIP switches and to the ON position on the copower motherboard (see section : System Configuration). For Master/Slave multiple installations, this must be the Thermostat Master unit Page 0

11 . SYSTM CONFIGURATION. Optional features WARNING: Isolate and disconnect air curtain from the power source before making any changes. DIP switches fitted to the air curtain motherboard (see Fig ) provide the following optional features, as explained below: heat interlock Disable fan run-on Thermostat master for master/slave installations Weather compensation heat control Fig Function Control Comments Factory Setting heat interlock Allows fan speed to govern heat output on electric heated units. If low or medium fan speed is selected, a lower heat output results. High heat operates only on high fan speed. Disable fan run-on The minute fan run-on after switch off is enabled or disabled on electric heated air curtains. DIP ON OFF DIP ON OFF This function applies to electric heated air curtains only to limit high air temperatures. Set DIP to OFF if unit is water heated or ambient. Must only be used for LPHW and Ambient air curtains. ach air curtain must have DIP set to ON for no fan run-on. ON Heat output is governed by fan speed. OFF Run-on enabled. Thermostat master For master/slave installations. Only the air sensor thermistor in the thermostat master air curtain will be used for measuring air temperature. Set DIP switch to ON in the air curtain that will be the master unit. DIP ON OFF Air sensor thermistors in all slave air curtains will be ignored. Avoids some units blowing cold air and others blowing warm air in master/slave arrangements on larger doorways. OFF Air sensors on multiple installations measure and act independently Weather compensation heat control nables heat output of air curtain to vary with outside temperature. Set DIP switches and to ON to enable. See Note below. DIP & DIP shown ON for fan heat interlock. Set DIP to ON in master/ slave installations. If enabled, connect a suitable outside air temperature sensor (e.g. Siemens QAC00) to the air curtain terminal block (see section 0.: Weather compensation). See Note below for weather compensation heat control strategy. OFF Weather compensation not active Page

12 Note See section 0.: Weather compensation for details of outside air temperature sensor and wiring to the air curtain. Set DIP switch and to the ON position in the air curtain that has the outdoor air temperature sensor wired into it. For Master/Slave multiple installations this must be the Thermostat Master unit. Note When remote controller is set to automatic the outdoor air temperature determines the heat output as follows: Less than 0 C / 0 F, full heat operates. Between 0 C / 0 F and C / 0 F, half-heat operates. More than C / 0 F, no heat operates. MULTIPL AIR CURTAINS When controlling multiple air curtains in a master/slave arrangement, plug the remote controller into any one of the units. Connect this unit to other unit(s) with a Thermoscreen RJ extension lead (not supplied), as per the diagram below. ach air curtain must have its own electrical supply Page

13 . FAN SPD SLCTION If required, select fan speed at commissioning to suit outdoor environmental conditions and indoor noise levels. Factory settings for the fan speeds are as follows: HIGH fan speed (black wire) is wired into motor tapping (highest motor speed tapping) MDIUM fan speed (blue wire) is wired into motor tapping LOW fan speed (red wire) is wired into motor tapping Set fan speeds according to the following tables: motor tapping: running on 08v (refer to wiring diagrams) Speed (air curtain as delivered) Speed Tapping Maximum air curtain mounting height (m / ft) Sound Pressure Level of air curtain [db(a) at m/0ft] Air Volume Flow Rate (m /h / cfm) HIGH (black wire) MDIUM (blue wire) LOW (red wire) (highest speed) air velocity at discharge is 0 m/s / 970 ft/min (lowest speed). / ft in.0 / 9ft 0in. / 7ft 0in.9 / ft in. / ft in HX000-8 HX00-8 HX000-8 HX000 - HX00 - HX000 - HX000-0 HX00-9 HX000-0 HX000-7 HX00 - HX000-7 HX000 - HX00-0 HX000-0 / / 8 / 0 0 / 0 0 / 90 / 7 9 / 90 / 70 8 / / 0 9 / 70 / 80 0 / 7 78 / 0 0 / 770 running on 0v (refer to wiring diagrams) Speed (air curtain as delivered) Speed Tapping Maximum air curtain mounting height (m / ft) Sound Pressure Level of air curtain [db(a) at m/0ft] Air Volume Flow Rate (m /h / cfm) HIGH (black wire) MDIUM (blue wire) LOW (red wire) (highest speed) air velocity at discharge is 0 m/s / 970 ft/min (lowest speed). / ft in. / 0ft in. / 8ft in. / ft 0in.8 / ft in HX000-0 HX00-0 HX000-0 HX000-8 HX00 - HX000-8 HX000 - HX00 - HX000 - HX000-8 HX00-7 HX000-8 HX000 - HX00 - HX000-0 / / 9 / 7 0 / / 08 9 / / / 90 / / 70 / / 0 7 / 0 90 / 0 / Page

14 . RMOT CONTROL OPRATION 7 Heating level scale Use the remote control to operate the air curtain as follows: On/Off Turns the air curtain On or Off. NOT: If an electric heated air curtain is heating when switched off the fan will run-on for approximately minutes to dissipate excess heat. Manual/Automatic Switches between Manual and Automatic modes. The Auto On indicator LD is lit for "Auto Mode" and unlit for "Manual Mode". & Heating level controls Manual mode Select heating level from zero, to half heat, to full heat by stepping up or down with the heating level controls. The heating level scale shows the level selected. Automatic mode Heat output is controlled automatically according to: Room air temperature Incoming air temperature, or xternal air temperature This is dependent on the settings made in Section : System Configuration (DIP switches and ), and Section 8: Remote Control Settings (DIP switch )., & 7 speed Switch fan speed between Low, Medium and High respectively. The appropriate LD illuminates Page

15 . COMMISSIONING TH SYSTM. Verify system operation To commission the system, verify the following conditions are met: All fans are working. s operate at Low, Medium and s. There is no excessive mechanical noise coming from the fans. When heating is selected, the air stream from the discharge grille warms up across the whole length of the air curtain. When set to manual with fans set to high speed, heating increases as higher heat is selected. Warm air reaches across the doorway with door open or closed. copower remote controller operates correctly in both manual and auto modes.. Instruct operator and hand over Before leaving site, hand over the installation to the end user or their representative. Recommend that any person operating the air curtain be given adequate instruction and supervision by a person responsible for their safety. Children and those with reduced physical, sensory or mental capabilities should not operate the air curtain. Recommend that the doorway should be closed whenever possible. Recommend that during times of high pedestrian use it will become an open doorway. The air curtain then serves an essential purpose by saving energy and providing comfort to occupants. xplain that the inlet grilles and air filters (if fitted) must be cleaned regularly and the unit serviced at schedule intervals see section 8: Service & Maintenance.. SIGN OFF Complete the following once commissioning is completed. Installer signature: Installer name: Company name: Date: Page

16 7. FAULT CONDITIONS 7. Thermal cut-out An overheat fault in electric heated units may cause the thermal cut-out trip(s) to operate. This is indicated by flashing LDs on the remote control and a red status LD on the air curtain motherboard. Before resetting ensure there is adequate air flow from the air curtain and the unit has been commissioned as per section. To reset a thermal cut-out trip: Step Step Step Step Switch off the electrical supply to the air curtain. Allow time for the air curtain to cool down, typically 0 minutes. Switch on the electrical supply to the air curtain. Press the Auto button on the remote control times. Air curtain heaters will then operate and after 0 seconds the LDs on the remote control will stop flashing and the status LD will flash green. 7. Fuses In the event of an electrical fault internal electrical fuses may operate. There are two internal fuses located on the motherboard inside the air curtain: Fuse.A (T) supplies the fan motors within the air curtain Fuse 00mA (F) controls the operation of the motherboard 7. PCB status indication LD on the air curtain motherboard is a status LD (See LD on Appendices, Wiring Diagrams). This indicates the status of the copower Control system as follows:. LD flashing green operation normal. LD flashing red low supply voltage or controller not plugged into motherboard. LD permanently red thermal cut-outs open circuit from an overheat situation (see Section 7, Fault Conditions for how to reset). LD flashing alternate red/green air curtain configured for Weather Compensation Control (DIP and ON) but no outdoor air sensor is connected to copower PCB. Remote Control LDs will also flash to indicate a connection error Page

17 8. SRVIC & MAINTNANC WARNING: Failure to adequately maintain the unit and provide a suitable cleaning schedule will result in performance degradation, reduction in life expectancy of the air-curtain and possible overheating and fire risk with electric heated units 8. very week NOT: Weekly maintenance can be carried out by the Cleaner or Janitor from floor level. Turn off the air curtain to prevent dust entry, then clean the face of the air inlet grille and air filter inside the grille using a vacuum cleaner with an extension tube and brush. 8. very months WARNING: Before servicing, isolate and disconnect the air curtain from the power source. WARNING: The following servicing, maintenance must be carried out by a competent electrician or a Thermoscreens appointed technician. Clean and inspect the inside of the air curtain as follows: Step Step Open the hinged inlet grille using a flat headed screwdriver to release the quarter turn fasteners (see Fig, Section 7.). Clean and remove any build-up of dust and dirt within the air-curtain (inlet/outlet grilles, fan impellers, housings and motors) using a vacuum cleaner and soft brush. NOT: Build-up of dirt on fan impellers can cause vibration, noise and excessive wear on the motor bearings. Step Step Check within the unit to ensure all electrical connections and crimped terminals are tight. On electric heated air curtains, remove the fan deck(s) as follows to inspect electric heaters, electrical wiring and connections and to remove dust, dirt and debris: Unclip the fan motor electrical connector. Unfasten x M nuts/bolts on each fan deck. Unfasten M screws at bottom edge of fan deck. Carefully lift the fan deck away from the air curtain. Refit fan deck(s) and close the hinged air inlet grille after servicing. Reconnect electrical supply and test to ensure correct operation (see Section : Commissioning) Page 7

18 9. WARRANTY All units are covered by a two year warranty. Failure to adequately maintain the unit may void the warranty. If any problems are encountered, please contact your installer/supplier. Failing this please contact Thermoscreens Canada. Care has been taken in compiling these instructions to ensure they are correct. Thermoscreens Canada disclaims all liability for damage resulting from any inaccuracies and/or deficiencies in this documentation. Thermoscreens Canada retain the right to change the specifications stated in these instructions. Thermoscreens Canada Toll Free: King Street, Unit # Tel: Barrie, Ontario Fax: Canada LN BS mail: salescanada@thermoscreens.com Page 8

19 8 / 9. CILING LVL (ffective Width of Airstream) D 8 /.7 / 0. 9 /. A mm / inch B C HX000R Cut-Out in Ceiling /.0 /.0 /. HX00R HX000R 70 / 7. / / /.7 Holes for M0 / 8 UNC drop rods, for m unit, for.m & m units Use all drop rod holes! / 0. 7 / /. 9 /.7 09 /.7 A B C D - - ntry points for electrical supply and controls Rp¾ / ¾ in. BSPP LPHW connections 8 / / / /. 0 /. 0 / /.7 70 / 7. / / 9. 8 / 9. 8 / 9. Length Width APPNDIX DIMNSIONS OF HX RCSSD AIR CURTAIN Page 9

20 TRMINAL BLOCK 08V / ph / 0Hz L L L L L L F, F -.A (T) F F xternal Air Sensor A NO A NO 0V AC Coil K K 0V AC Coil 8 C H Auto Thermal Trip A NO A NO Yellow F =.A (T) F = 00mA (F) Link To Slave Air Curtain F F J J Master/Slave Cable Yellow K Live K HALTHY INHIBIT K K RMOT CONTROL.0 kw (x).0 kw (x).0 kw (x).0 kw (x) LD ON Live K K K7 Live K8 K9 K0 Second Stage Heating (top elements) First Stage Heating (bottom elements) COPOWR CONTROLLR - CVR 008 ~ (COMMON) Brown (High) Grey Violet Orange (Low) 0 APPNDIX A WIRING DIAGRAM -HX000R 08V Page 0

21 TRMINAL BLOCK 08V / ph / 0Hz L L L L L L F, F -.A (T) F F xternal Air Sensor A NO A NO A NO 0V AC Coil K 0V AC Coil K 0V AC Coil K 8 C H Auto Thermal Trip A NO A NO A NO Yellow Yellow F =.A (T) F = 00mA (F) Link To Slave Air Curtain F F J J Master/Slave Cable Yellow K Live K HALTHY INHIBIT K K RMOT CONTROL.0 kw (x).0 kw (x).0 kw (x).0 kw (x) LD ON Live K K K7.0 kw (x).0 kw (x) Live K8 K9 K0 COPOWR CONTROLLR - CVR 008 ~ (COMMON) Brown (High) Grey Violet Orange (Low) Second Stage Heating (top elements) First Stage Heating (bottom elements) 0 APPNDIX B WIRING DIAGRAM HX00R 08V Page

22 A NO 0V AC Coil A NO TRMINAL BLOCK 08V / ph / 0Hz L L L L L L F, F -.A (T) F F xternal Air Sensor A NO A NO A NO K 0V AC Coil K 0V AC Coil K 0V AC Coil K A NO A NO A NO 8 C H Auto Thermal Trip (x) Yellow Yellow F =.A (T) F = 00mA (F) Link J J To Slave Air Curtain Master/Slave Cable Yellow F F K Live K HALTHY INHIBIT K K RMOT CONTROL.0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x) LD ON Live K K K7 Live K8 K9 K0 COPOWR CONTROLLR - CVR 008 ~ (COMMON) Brown (High) Grey Violet Orange (Low) (COMMON) 0 Second Stage Heating (top elements) First Stage Heating (bottom elements) ~ Brown (High) Grey Violet Orange (Low) 0 APPNDIX C WIRING DIAGRAM HX000R 08V Page

23 WARNING! UNIT RQUIRS MOR THAN ON SOURC OF LCTRICAL POWR TRMINAL BLOCK 80V / ph / 0Hz or 00V / ph / 0Hz L L L L L L F, F -.A (T) F F A NO A NO 08V or 0V Disconnecting means integral to the unit for both sources of electrical power is required! 0V AC Coil K 0V AC Coil K 8 C H Auto Thermal Trip A NO A NO xternal Air Sensor Yellow F =.A (T) F = 00mA (F) Link F F K Live K J J Yellow Master/Slave Cable *s *s HALTHY INHIBIT To Slave Air Curtain K K RMOT CONTROL.0 kw (x).0 kw (x) LD ON Live K K K7 *s *s.0 kw (x).0 kw (x) Live K8 K9 K0 *s *s COPOWR CONTROLLR - CVR 008 Second Stage Heating (top elements) First Stage Heating (bottom elements) *s - star point connection: st Stage -.mm² tri-rated cables nd Stage -.mm² Grey tri-rated cables (COMMON) Brown (High) Grey Violet Orange ~ (Low) 0 APPNDIX D WIRING DIAGRAM -HX000R 80V or 00V Page

24 WARNING! UNIT RQUIRS MOR THAN ON SOURC OF LCTRICAL POWR TRMINAL BLOCK 80V / ph / 0Hz or 00V / ph / 0Hz L L L L L L F, F -.A (T) F F A NO A NO 08V or 0V Disconnecting means integral to the unit for both sources of electrical power is required! 0V AC Coil K 0V AC Coil K 8 C H Auto Thermal Trip (x) A NO A NO xternal Air Sensor Yellow F =.A (T) F = 00mA (F) Link F F K Live K J J Yellow Master/Slave Cable *s *s *s HALTHY INHIBIT To Slave Air Curtain K K RMOT CONTROL.0 kw (x).0 kw (x) LD ON Live K K K7 *s *s *s.0 kw (x).0 kw (x) Live K8 K9 K0 *s *s *s *s - star point connection: st Stage -.mm² tri-rated cables nd Stage -.mm² Grey tri-rated cables COPOWR CONTROLLR - CVR kw (x).0 kw (x) ~ Second Stage Heating (top elements) First Stage Heating (bottom elements) (COMMON) Brown (High) Grey Violet Orange (Low) 0 APPNDIX WIRING DIAGRAM HX00R 80V or 00V Page

25 WARNING! UNIT RQUIRS MOR THAN ON SOURC OF LCTRICAL POWR TRMINAL BLOCK 80V / ph / 0Hz or 00V / ph / 0Hz L L L L L L F, F -.A (T) F F A NO A NO 8 C H Auto Thermal Trip (x) 08V or 0V Disconnecting means integral to the unit for both sources of electrical power is required! 0V AC Coil K 0V AC Coil K A NO A NO xternal Air Sensor Yellow F =.A (T) F = 00mA (F) Link F F J J *s *s Yellow Master/Slave Cable Live K HALTHY INHIBIT To Slave Air Curtain RMOT CONTROL LD ON Live K *s *s.0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x).0 kw (x) Live K8 *s *s K0 *s *s (COMMON) Brown (High) Grey Violet Orange ~ (Low) COPOWR CONTROLLR - CVR 008 *s *s 0 (COMMON) ~ Brown (High) Grey Violet Orange (Low) *s *s *s - star point connection: st Stage -.mm² tri-rated cables nd Stage -.mm² Grey tri-rated cables 0 Second Stage Heating (top elements) First Stage Heating (bottom elements) APPNDIX F WIRING DIAGRAM HX000R 80V or 00V Page

26 TRMINAL BLOCK F, F -.A (T) F 08V or 0V Brown F L L L L PORT VALV F =.A (T) F = 00mA (F) xternal Air Sensor F F J J Grey Orange Green/Yellow Brown K Live K Master/Slave Cable HALTHY INHIBIT To Slave Air Curtain K K RMOT CONTROL LD ON Live K K K7 Live K8 K9 K0 COPOWR CONTROLLR - CVR 008 ~ (COMMON) Brown (High) Grey Violet Orange (Low) (COMMON) 0 ~ Brown (High) Grey Violet Orange (Low) (m only) 0 APPNDIX G WIRING DIAGRAM HX000WR, HX00WR and HX000WR Page

27 TRMINAL BLOCK F, F -.A (T) F 08V or 0V Brown F L L L L F =.A (T) F = 00mA (F) F F J J K Master/Slave Cable Brown Live K HALTHY INHIBIT To Slave Air Curtain K K RMOT CONTROL LD ON Live K K K7 Live K8 K9 K0 COPOWR CONTROLLR - CVR 008 (COMMON) (m only) ~ Brown (High) Grey Violet Orange (Low) ~ (COMMON) Brown (High) Grey Violet Orange (Low) 0 0 APPNDIX H WIRING DIAGRAM HX000AR, HX00AR and HX000AR Page 7

AIR CURTAIN HX SURFACE MOUNTED RANGE

AIR CURTAIN HX SURFACE MOUNTED RANGE AIR CURTAIN HX SURFAC MOUNTD RANG INSTALLATI, OPRATI AND MAINTNANC INSTRUCTIS N. America nglish T99009-- CAN-USA-NG (v9) (with ABB TF Thermal Overload Relays) Page CTNTS Page CTNTS... LCTRICAL SAFTY...

More information

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire England

More information

AIR CURTAIN DESIGNER C RANGE Horizontal and Vertical

AIR CURTAIN DESIGNER C RANGE Horizontal and Vertical AIR CURTAIN DESIGNER C RANGE Horizontal and Vertical INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS English T9901015-6-1 UK (v9) Page 1 1 CONTENTS Page 1 CONTENTS... 2 2 ELECTRICAL SAFETY... 3 3

More information

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire

More information

AIR CURTAIN DESIGNER PHV RANGE Horizontal and Vertical

AIR CURTAIN DESIGNER PHV RANGE Horizontal and Vertical AIR CURTAI DESIGER PHV RAGE Horizontal and Vertical ISTALLATIO, OPERATIO AD MAITEACE ISTRUCTIOS English T990090-5- UK (v9) Page . COTETS. COTETS.... ELECTRICAL SAFETY... SPECIFICATIOS.... ITRODUCTIO...

More information

ACR RECESSED AIRCURTAIN ELECTRICALLY HEATED, AMBIENT & LPHW INSTALLATION AND OPERATING MANUAL

ACR RECESSED AIRCURTAIN ELECTRICALLY HEATED, AMBIENT & LPHW INSTALLATION AND OPERATING MANUAL Instruction Manual. ACR RECESSED AIRCURTAI ELECTRICALLY HEATED, AMBIET & LPHW ISTALLATIO AD OPERATIG MAUAL IDEX Section General information ----------------------------------------------------------- 1

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate separation

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT Model No. PEL00581 NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page

More information

(UK) Date : January 2014

(UK)   Date : January 2014 Sentinel Door Curtain - Model 270 Installation, Operation & Maintenance Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document

More information

IDENTIFICATION ACCESSORIES DESCRIPTION

IDENTIFICATION ACCESSORIES DESCRIPTION Sentinel Doorway mounted air curtain. 1000mm, 1500mm & 2000mm widths. 1800 to 2700mm mounting height. Soffit drop rod or wall bracket mounted. Ambient air, 3 phase electric or LPHW heating. 1 IDENTIFICATION

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate separation

More information

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start) AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE

More information

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the

More information

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT Model No. PEL00580 MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre

More information

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Instruction Manual. Q Series 2 Motor Control Modules - OEM A382-21-880 Issue B Instruction Manual Q Series 2 Motor Control Modules - OEM Pump/ Q Motor Control Module Item Number pumping system Electrical supply 24 V d.c. control 24 V a.c. control QDP40 200-230

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain Revolutionary climate separation The SensAir comfort air curtain sets a new standard in the field of climate separation. The highest level of comfort

More information

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller

More information

INSTALLATION & MAINTENANCE MANUAL HBL

INSTALLATION & MAINTENANCE MANUAL HBL INSTALLATI & MAINTENANCE MANUAL HBL series 230V 50Hz IP 65 122 1 GENERAL INSTRUCTIS These instructions should be read carefully and retained after installation by the end user for future reference and

More information

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS (27/6/13) Contents 1. GENERAL DESCRIPTION... 2 2. RECEIPT AND PREPARATION... 2 3. INSTALLATION... 2 3.1. REMOVAL OF ACCESS PANEL... 2 3.2. FIXING A PLINTH...

More information

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR INTRODUCTION The LED AC Driverless Floodlights with PIR include a hanging / mounting bracket and a 100cm cable. SPECIFICATION LED 800-4000lm IP65 180-240V IK07 6000K 50Hz >80 Ra 10W- 50W Dimensions: FLAC10BPIR:

More information

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY EXHAUST BRAKES C40019 1999-2003 FORD F250 / F350 7.3L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY Getting Started Thank you and congratulations on your purchase of a Pacbrake exhaust retarder.

More information

air curtains CONTENTS THERMOSCREENS... 04 WHY FIT AN AIR CURTAIN?... 05 AIR CURTAIN SELECTION GUIDE... 06 THERMOSCREENS SELECTION OVERVIEW... 07 AIR VELOCITY DISTRIBUTION CHART... 08 ECOPOWER CONTROL...

More information

THERMOSCREENS AIR CURTAINS

THERMOSCREENS AIR CURTAINS INDEX c-range recessed... 12-4 surface mounted... 12-4 introduction... 12-2 Jet range... 12-6 -range recessed... 12-5 surface mounted... 12-5 selection guide... 12-3 technical data... 12-7 12-11 This section

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

Operations and Service Manual. X30208 Load Bank

Operations and Service Manual. X30208 Load Bank Operations and Service Manual Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a)... 4 3) Receiving... 5 4) Safety... 5 a) Ground

More information

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 V3 TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 PREFACE This guide contains instructions for troubleshooting the Steffes Corporation room heating units: Models HPB 11, HPB

More information

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately notify shipping company. If the unit(s) were shipped on wooden skids, remove protective wood

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide This guide contains information for identifying and correcting issues that may arise. Applicable Models: i200 i200p i250 i250p i200x i201x i250x i251x iq251 iq251d iq751 iq1001 iq1501

More information

Installation and Operation Instructions

Installation and Operation Instructions Installation and Operation Instructions FlushMaster Cistern & Valve Assembly Model 43099 - FlushMaster Std. Cistern* and Valve assembly (75mm Body) Model 41096 - FlushMaster Cistern Outlet valve 75mm dia.

More information

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Sieve Shaker 200mm/300mm - 8/12 inch SV003 Sieve Shaker 200mm/300mm - 8/12 inch SV003 CONTENTS Introduction Specification Installation Controls Operation Maintenance Spares and Accessories 1 Introduction The unique action of this Sieve Shaker (Fig

More information

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators abc GB HR25 Solo Installation and User Instructions Models:- HR25 Solo HR25 Solo L HR25 Solo H HR25 Solo LH Through the Wall Heat Recovery Ventilators PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

INSTALLER MANUAL USER MANUAL. Contents

INSTALLER MANUAL USER MANUAL. Contents Installation & user manual two way Contents INSTALLER MANUAL Important information General 1. Technical data 2. Description Installation: 1. Positioning the unit 2. Connection. 3. Parts description. 4.

More information

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes Instructions for the BASIC BCVA Rotary heat exchanger, Sizes 080 120 1. General The BCVA heat recovery unit is a rotary heat exchanger that offers high temperature efficiency. The heat exchanger operates

More information

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd. MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS Distributed by CLARKE International Ltd. 1006 Thank you for selecting this VAC KING Stainless Steel Vacuum Cleaner, which will

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible

More information

2 PORT MOTORISED VALVE (28 mm)

2 PORT MOTORISED VALVE (28 mm) 2 PORT MOTORISED VALVE (28 mm) Model No SBMV28 Instruction Manual 2 SBMV28 INSTRUCTION MANUAL PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: Electro-Magnetic

More information

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMPS SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety

More information

X100P Load Bank. Read all instructions before using the load bank. Contents

X100P Load Bank. Read all instructions before using the load bank. Contents X100P Load Bank Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a) X100P Load Bank... 4 3) Receiving... 4 4) Safety... 5 a) Grounding...

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only)

INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only) INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only) BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 0VDC ACTUAL FAN ERROR SET FAN (English) (Industrial Controller

More information

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.

More information

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide ICM325HN Head Pressure Control with Optional Heat Pump Override Temperature sensitive control regulates head pressure Installation, Operation & Application Guide For more information on our complete range

More information

LED Pinspot 2. Snapshot. User Manual

LED Pinspot 2. Snapshot. User Manual LED Pinspot 2 Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle User Manual 3000 N 29 th Ct, Hollywood, FL 33020

More information

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP SUBMERSIBLE WATER PUMP MODEL NO: CSV1A, CSV2A PART NO: 7230582, 7230602 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS 05/14 iss 4 INTRODUCTION Thank you for purchasing this CLARKE Submersible

More information

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.

More information

LED Pinspot 2. Snapshot. User Manual

LED Pinspot 2. Snapshot. User Manual LED Pinspot 2 Snapshot Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User-Serviceable User Manual 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.

More information

PowerOhm Installation Manual for BM R Series Braking Modules

PowerOhm Installation Manual for BM R Series Braking Modules PowerOhm Installation Manual for BM R Series Braking Modules IMPORTANT: These instructions should be read thoroughly before installation. All warnings and precautions should be observed for both personal

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806 SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2

More information

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010 ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS LS1010 INTRODUCTION Thank you for purchasing this CLARKE Electric Hoist. Before attempting to use

More information

24V 3A EN54 Ancillary Power Supply

24V 3A EN54 Ancillary Power Supply 24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING TROUBLESHOOTING for the 5 BUTTON 3109228.001 COMFORT CONTROL CENTER SYSTEM INTRODUCTION The Comfort Control Center control system can be used to operate the following Duo-Therm Units: Roof Top Air Conditioners

More information

XS400 Load Bank. Read all instructions before using the load bank. Contents

XS400 Load Bank. Read all instructions before using the load bank. Contents Read all instructions before using the load bank Contents 1) Components... 3 Total Assembly... 3 2) Specifications... 4 3) Receiving... 4 4) Safety... 5 a) Grounding cam... 6 b) Power connections... 6

More information

Indoor air quality sensor.

Indoor air quality sensor. Indoor air quality sensor. Options and Accessories, Installation manual Ref.: N-40175_EN 1107 Index Index 1 Indoor air quality sensor... 1 1.1 General Information... 2 1.2 General measurements... 2 1.3

More information

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable. Snapshot Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable User Manual TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 WHAT IS INCLUDED... 3

More information

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS Intelligent Battery System GmbH Seestrasse 24, CH-3600 Thun, Schweiz Tel: +41 33 221 06 16 Fax: +41 33 221 06 17 E-Mail: info@ibs-tech.ch Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS-USG4_en_v2.0.3.doc

More information

POND PUMP Model Nos:SPP3 & SPP6 0200

POND PUMP Model Nos:SPP3 & SPP6 0200 OPERATING & MAINTENANCE INSTRUCTIONS POND PUMP Model Nos:SPP3 & SPP6 0200 Thank you for purchasing this CLARKE Water Pump, which is particularly suitable for the filtration of small to medium size swimming

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 750W SUBMERSIBLE PUMP WITH BUILT-IN FLOAT SWITCH MODEL NO: PSV5A PART NO: 7236046 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 iss 3 INTRODUCTION Thank you for purchasing this CLARKE

More information

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT Model No. PEL00588 MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page test record can

More information

Measurements are expressed in millimeters.

Measurements are expressed in millimeters. T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164

More information

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105 250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105 PART NO: 7230693 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 -- iss 3 INTRODUCTION Thank you for purchasing this CLARKE 250W Puddle

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax: Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

Wilo-Control SC-Fire Jockey

Wilo-Control SC-Fire Jockey Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

FlushMaster Cistern & Valve assembly

FlushMaster Cistern & Valve assembly Installation and operation instructions FlushMaster Cistern & Valve assembly Model 43099NZ - FlushMaster Std. Cistern* and Valve assembly (75mm Body) Model 41096NZ - FlushMaster Cistern Outlet valve 75mm

More information

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Pure Sine Wave Inverter GP-HS1500. Owner s Manual Pure Sine Wave Inverter GP-HS1500 Owner s Manual 2 Table of Contents Introduction 3 Specifications 4 Name and Main Function 5 Installation 7 Operation 9 Operating Limits 13 Troubleshooting 13 Maintenance

More information

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER HIGH FREQUENCY AUTOMATIC BATTERY CHARGER MODEL NO: HFBC12 PART NO: 6267000 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE High Frequency Automatic Battery

More information

MANUAL RECESSED AIR CURTAINS

MANUAL RECESSED AIR CURTAINS R MANUAL RECESSED AIR CURTAINS CONTENTS Page GENERAL GUIDLINES... LABELING & SYMBOLISM... INSTALLATION INSTRUCTIONS... POWER SUPPLY CONNECTIONS... MAINTENANCE AND SERVICE... WARRANTY... TECHNICAL CHARACTERISTICS...

More information

CALTRAP INSTALLATION AND OPERATIONS MANUAL

CALTRAP INSTALLATION AND OPERATIONS MANUAL INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.

More information

PIL0478 ISSUE 01/ 07/16

PIL0478 ISSUE 01/ 07/16 ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

Multi directional heating. Air heaters Model NOZ

Multi directional heating. Air heaters Model NOZ Multi directional heating Air heaters Model NOZ Air heaters The ideal heat source for large buildings Air heaters are used for the heating and ventilation of large industrial buildings. New industrial

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. Technical Information and Diagnostic Guide for SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. This guide will assist you in becoming more

More information

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST

More information

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX10 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A.

More information

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS www.r-techwelding.co.uk MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS 2 Thank you for selecting the R-Tech MMA160S Inverter Arc Welder. The MMA160S has many benefits over traditional Arc welders, including

More information

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT Model No. PEL00582 MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page test record

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

3 PORT MOTORISED VALVE (22 mm)

3 PORT MOTORISED VALVE (22 mm) Salus SBMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 10:56 Page 1 3 PORT MOTORISED VALVE (22 mm) Model No SBMV32 Instruction Manual Salus SBMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 10:56 Page 2 2

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS www.r-techwelding.co.uk Email: sales@r-techwelding.co.uk Tel: 01452 733933 Fax: 01452 733939 ProArc 175 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2017-10 2 3 Thank you for selecting the R-Tech

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

Sectional And Tilting Door Opener

Sectional And Tilting Door Opener Sectional And Tilting Door Opener Installation Instructions and User Guide FS 600 FS 1000 FS 1200 600N 1000N 1200N FS 600-Speed FS 1000-Speed 600N 1000N S/N WARNING Please read the manual carefully before

More information

Features: Available in horizontal and vertical units

Features: Available in horizontal and vertical units Features: Available in horizontal and vertical units Ideal for Shopping Malls, Retail Outlets and Office Receptions Can be supplied in a large range of colours and finishes Numerous mounting bracket arrangements

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

3 PORT MOTORISED VALVE (32/38 mm)

3 PORT MOTORISED VALVE (32/38 mm) 3 PORT MOTORISED VALVE (32/38 mm) Model No SBMV32/38 Instruction Manual 2 SBMV32 INSTRUCTION MANUAL PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives:

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information