Parts & Service. Terreon Multi-Fount Washfountain Current Models After February 1, MF2922 Corner-Fount. MF2933 Tri-Fount

Size: px
Start display at page:

Download "Parts & Service. Terreon Multi-Fount Washfountain Current Models After February 1, MF2922 Corner-Fount. MF2933 Tri-Fount"

Transcription

1 MF9 (AST shown) MF9 (AST shown) Parts & Service Terreon Multi-Fount Washfountain Current Models After February, 0 MF9 Corner-Fount MF9 Tri-Fount MF99 Tri-Fount, Wall-Hung MF9 Quadra-Fount MF99 Quadra-Fount, Wall-Hung MF99 (AST shown) Table of Contents Infrared (IR)... Air Metering (AST)... AST and IR Supply and Mixing Valve... 0 Battery Infrared (BIR)... TouchTime (TT)... Thermostatic Mixing Valve Troubleshooting... Soap System... 9 Drain Spud and Strainer... Floor Pedestal Assembly... Wall Mount Pedestal Assembly... Sprayhead Covers... Pedestal Panels... Bowl Assembly... Terreon Cleaning and Maintenance... MF9 (AST shown) Part numbers are subject to change without formal notice. MF99 (AST shown) - Rev. J; ECN Bradley Page of 9//0 P.O. Box 09 Menomonee Falls, WI 0 USA 00 BRADLEY (00 9) bradleycorp.com

2 Terreon Multi-Fount Washfountains Parts and Service Infrared (IR) Sprayhead (V Plug-In Transformer) 0 9 Parts List Infrared Sensor and Sprayhead Assembly Corner Tri Quad Qty. Qty. Qty. 9-0 Sensor - Adaptive - P0-9 Hook and Loop Fastener Strip (sensor mounting) 9-90 Window - Sprayhead -9 Threaded Rod 0- Backplate -0 Nut -00BS Lockwasher 9- Fitting Straight (front sprayhead) Fitting Swivel 90 (side sprayheads) 0 R-00-R Tubing /", Red * * * 0 R-000-G Tubing /", Green * * * 0 R-000-B Tubing /", Black * * * 0 R-000-Y Tubing /", Yellow * * * * Specify length in feet 9//0 Bradley - Rev. J; ECN -00-0

3 Parts and Service Terreon Multi-Fount Washfountains Infrared (IR) Valves (V Plug-In Transformer) Red Supply Tube (From Sprayhead) Red Spade Terminal Green Supply Tube (From Sprayhead) Black Supply Tube (From Sprayhead) White Jumper Terminals Green Spade Terminal 9 0 Black Spade Terminal White Spade Terminal Tri-Fount Shown Parts List Solenoid Valve Assembly and Valve Parts Corner Tri Quad Qty. Qty. Qty. S-9 IR TMA Dual valve Assembly (includes items -) - - S-9 IR TL Dual Valve Assembly (includes items -) - - S-9 IR TMA Tri Valve Assembly (includes items -) - - S-9 IR TL Tri Valve Assembly (includes items -) - - S- IR TMA Quad Valve Assembly (includes items -) - - S- IR TL Quad Valve Assembly (includes items -) - - S0- Navigator Valve, GP 0-9 Bracket, Ganged Valve 9 P-0 Screw 0- x / PN 0 S0-0A Solenoid Valve, VAC, through S0-0 Solenoid Valve, VAC, closed 0- Compression Nut, /" 0- Screw - x / PN S9-0 Adapter, Valve Inlet S- Transformer Bradley - Rev. J; ECN //0

4 Terreon Multi-Fount Washfountains Parts and Service Infrared (IR) Valve Assembly - Solenoid Valve S0-0S (Closed Body) and S0-0AS (Thru Body) Solenoid Valve Parts List Qty -0 Valve Body, /" Closed -0A Valve Body, /", Through 9-9 Diaphragm 9- Armature 9- Spring 9-9 Armature Housing 9-0 clamp, Armature Housing 9-9 Coil, Solenoid Valve 0- Screw # x / 9 - O-Ring, # Flow Restrictor, 0. GPM S- Repair Kit 0 9 Turn off water supplies to unit before troubleshooting. Problem Cause Solution An individual operating station fails to shut off and drips. An individual operating station fails to turn on. There is debris trapped between the diaphragm and the valve seat. A failed coil for the valve or loose electrical connection to the terminal. Remove debris between diaphragm and the valve seat.. Remove the three # Phillips-head screws that hold the solenoid valve assembly together. Be careful not to lose the armature or spring (see previous page).. Remove the diaphragm. Remove any particles that have been trapped between the diaphragm and the valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center orifice and both small side orifices are open.. Reassemble in reverse order, being careful not to overtighten the Phillips-head screws or you may crack the plastic valve body. Tighten until the armature plate makes contact with the plastic body.. Reconnect the wiring per diagram. Test the station to determine cause.. Disconnect the wires from the coil of an adjacent valve. Disconnect the wires from the problem valve and reconnect to the adjacent valve.. Turn on electrical and water supplies to the unit. Place hands in front of sensor for the problem station; the adjacent station should turn on. If the adjacent station turns on and cycles normally, replace the coil on the problem valve. If the adjacent valve fails to turn on, inspect the wires from the sensor cable and do the following: make sure there are no breaks and that the fully insulated disconnect terminals are firmly crimped in place; turn off the electrical and water supplies; reconnect to the adjacent valve and turn on the water supplies to the unit; place hands in front of sensor. If the station still fails to turn on, replace the sensor. 9//0 Bradley - Rev. J; ECN -00-0

5 Parts and Service Terreon Multi-Fount Washfountains Air Metering Valve (AST) - Pushbutton and Sprayhead Bradley - Rev. J; ECN //0

6 Terreon Multi-Fount Washfountains Parts and Service Parts List AST Pushbutton and Sprayhead Corner Tri Quad Qty. Qty. Qty. S0-0 Pushbutton Assembly (Includes Items thru ) -090 Pushbutton Only 9-0 Guide for Pushbutton -0 Shoulder Screw for Pushbutton -0 Spacer 0- Brackey 0- Nut - S- Actuator Assembly (Includes Items 9 thru ) - S-A Actuator Assembly (Includes Items 9 thru ) A Piston U-Cup -0 Spring -9 Actuator Body 9-00 Duckbill Check 9-90 Tube Connector /" Straight 9- Fitting Adj J - 0- Screw R-0000-R Tubing /" OD, Red * * * R-0000-G Tubing /" OD, Green * * * R-0000-B Tubing /" OD, Black * * * R-0000-Y Tubing /" OD, Yellow * * * - Sprayhead 9-9 Threaded Rod Window Hole Plug 0- Backplate -0 Nut -00BS Lockwasher 9- Fitting Straight (Front Sprayhead) - 9- Fitting Swivel 90 (Side Sprayheads) R-000-R Tubing /" ID, Red * * * R-000-G Tubing /" ID, Green * * * R-000-B Tubing /" ID, Black * * * R-000-Y Tubing /" ID, Yellow * * * 0-0 Spanner Wrench * Specify length in feet. 9//0 Bradley - Rev. J; ECN -00-0

7 Parts and Service Terreon Multi-Fount Washfountains Air Metering Valve (AST) - Assembly 0 9 Parts List Air Metering Valve Assembly Corner Tri Quad Qty. Qty. Qty. S0-TMA TMA Dual Valve Assembly (Includes Items thru ) - - S0-TL TL Dual Valve Assembly (Includes Items thru ) - - S0-TMA TMA Tri Valve Assembly (Includes Items thru ) - - S0-TL TL Tri Valve Assembly (Includes Items thru ) - - S0-TMA TMA Quad Valve Assembly (Includes Items thru ) - - S0-TL TL Quad Valve Assembly (Includes Items thru ) - - S0- Navigator Valve, GP 0-9 Bracket, Ganged Valve 9 P-0 Screw 0- x / PN 0 S0-0AS AST Valve, Through S0-0S AST Valve, Closed 0- Compression Nut, /" 0- Screw - x / PN S9-0 Adapter, Valve Inlet Bradley - Rev. J; ECN //0

8 Terreon Multi-Fount Washfountains Parts and Service AST Valve Repair Kits 9 0 Parts List AST Valve Repair Kits - O-Ring -0A Valve Body - Manifolded -0 Valve Body - Closed 9-9 Diaphragm 9- Armature, Valve 9- Spring, Valve -09 Cover, AST Valve 0- Cover, AST Valve Timer 9 S-0 Timer, ASM, AST Valve 0-00BY O-Ring 0- Compression Nut, /" S9-9 Magnet/Diaphragm Assembly 0- Cover, AST Valve 0- Clamp Nut, AST Valve 0-9 Screw - x /" S- Repair Kit - AST Valve - Upper S- Repair Kit - AST Valve - Lower S-0 Repair Kit - AST Valve - Complete 9//0 Bradley - Rev. J; ECN -00-0

9 Parts and Service Terreon Multi-Fount Washfountains Metering Air Valve Maintenance and Troubleshooting The air valve timer is located next to the tube connector on the air valve body. The timer is capped with a filter to prevent dirt build-up on the timer. The air valve timing can be adjusted from 0 seconds. Water Tube Connector Air Valve Manual Release Button Air Valve Tubing Locking Slope Filter Cap Air Tube Connector Sealing Ring Gripping Ridge Tube Stop Problem Cause Solution Air valve meter time needs adjusting. Adjust air valve meter time:. Remove filter cap and use a screwdriver to tighten or loosen the timer (see illustration above). Turning the timer clockwise increases the time; turning the timer counterclockwise decreases the time. Valve will not shut off. Valve will not turn on. Timing can not be adjusted for more than seconds. Push button does not work properly. Water is dripping from the streamformers. Timing mechanism is clogged. Water is not being supplied to unit. Water pressure is over 0 PSI. Failed diaphragm/ magnet assembly. There is an air leak. Air volume may not be sufficient to operate valve. Debris has accumulated on valve seat or orifices.. Continue to adjust until the timer is set at desired length.. Replace filter cap over the timer. Clean and inspect timing mechanism:. If compressed air is available, blow water and debris from timer cover of timing mechanism.. Turn adjusting screw out all the way. Clean and inspect screw and valve body.. Turn adjusting screw in to desired cycle time. Open all stops on mixing valve. Install a pressure reducing valve. Unscrew the valve clamp nut on valve. Remove valve cover. Gently press the diaphragm. The valve should activate. If not, replace the diaphragm/magnet assembly. Check the valve assembly:. Check all tubing and fittings for proper assembly.. Tighten cap and nut on /" tubing. Check for leaks and lubricate U cup:. Check all fittings for air leaks.. Disassemble push button and lubricate U cup seal. Clean and inspect valve seat.. Remove screws and disassemble metering valve.. Clean valve seat and inspect for deep gouges or scratches. Replace valve body if necessary.. Remove any debris clogging off center hole in rubber diaphragm. Bradley - Rev. J; ECN //0 9

10 Terreon Multi-Fount Washfountains Parts and Service AST and IR Supply and Mixing Valve - Floor and Wall Mounted Air Valve Assembly Hot Supply Inlet Navigator TMV Cold Supply Inlet Floor Mount (Tri-Fount Shown) Hot Supply Inlet Cold Supply Inlet Air Valve Assembly Navigator TMV Wall Mount (Quadra-Fount Shown) Supply Parts List Corner Tri Quad Qty Qty Qty * 9-0 Flex Hose (Supply to TMV) * S-0 Stop 0-9 Screw * Use Qty for TL option, all models. 0 9//0 Bradley - Rev. J; ECN -00-0

11 Parts and Service Terreon Multi-Fount Washfountains Battery Infrared (BIR) - Sprayhead 0 9 Parts List - Battery Infrared Sensor and Sprayhead Corner Tri Quad Qty Qty Qty -09A Sensor Eye Leads 9-90 Window - Sprayhead -9 Threaded Rod 0- Backplate -0 Nut -00BS Lockwasher 9- Fitting Straight (front sprayhead) Fitting Swivel 90 (side sprayheads) 0 R-000-R Tubing /", Red * * * 0 R-000-G Tubing /", Green * * * 0 R-000-B Tubing /", Black * * * 0 R-000-Y Tubing /", Yellow * * * * Specify length in feet. Bradley - Rev. J; ECN //0

12 Terreon Multi-Fount Washfountains Parts and Service Battery Infrared Valve (BIR) - Assembly 9 0 Tri-Fount Shown 9 Parts List - Battery Infrared Valve Assembly Corner Tri Quad Qty Qty Qty S0-TMA TMA Dual Valve Assembly (includes items -) - - S0-TL TL Fual Valve Assembly (includes items -) - - S0-TMA TMA Tri Valve Assembly (includes items -) - - S0-TL TL Tri Valve Assembly (includes items -) - - S0-TMA TMA Quad Valve Assembly (includes items -) - - S0-TL TL Quad Valve Assembly (includes items -) - - S0- Navigator Valve, GP 0-9 Bracket, Ganged Valve 9 P-0 Screw 0- x / PN 0 S0-0AS BIR Valve, through (includes items -) S0-0S BIR Valve, closed (includes -) 0- Compression Nut, /" 0- Screw - x /" PN S9-0 Adapter, Valve Inlet S- Circuit Board 0- Screw #-9 x / S- Battery Holder 9-00 Lithium Battery, Type DLA or Equivalent 0 S-0 Battery Prepack (includes items -9) 9//0 Bradley - Rev. J; ECN -00-0

13 Parts and Service Terreon Multi-Fount Washfountains Battery Infrared Valve (BIR) Assembly - Solenoid Valve S0-0S (Closed Body) and S0-0AS (Thru Body) Item Qty Part No. Description -0 Valve Body, /" Closed -0A Valve Body, /" Thru 9-9 Diaphragm 9-0 Armature -09 Spring 9-9 Armature Housing 9-0 Clamp, Armature Housing 9- Coil, Solenoid Valve 0- SCrew, # x /" 9 - O-Ring, # Flow Restrictor,. GPM Solenoid Valve with Circuit Board Closed Body (S0-0S) Thru Body (S0-0AS) Circuit Board (S-) 0 Pan-Head Screw -9 x /" (0-) Bradley - Rev. J; ECN //0

14 Terreon Multi-Fount Washfountains Parts and Service Troubleshooting BIR Components CAUTION: Turn off water supplies to unit before troubleshooting. Problem: Cause: An individual operating station drips and fails to shut off. There is debris trapped between the diaphragm and the valve seat. Solution: Remove debris between diaphragm and the valve seat. Disconnect the plug from the battery to the circuit board of the problem valve. Remove the three # Phillips-head screws that hold the solenoid valve assembly together. Be careful not to lose the armature or spring. Remove the diaphragm. Remove any particles that are trapped between the diaphragm and the valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center orifice and both small side orifices are open. Reassemble in reverse order, being careful not to overtighten the Phillips-head screws or you may crack the plastic valve body. Tighten until the armature plate makes contact with the plastic body. Reconnect the battery plug. Turn on water supplies to the unit. Problem: Cause: Solution: An individual operating station fails to turn on or off. Excessive line pressure. Install pressure reducing valve. Check the static line pressure. If the pressure exceeds 0 psi, install a pressure reducer valve at the street main. Excessive line pressure (over 0 psi) will shorten the life of any valve. Problem: Cause: Solution: An individual operating station fails to turn on or off. A dead or faulty battery. Test the station to determine cause and replace battery if required. Disconnect the plug from the battery to the circuit board of the problem valve. Disconnect the plug from the battery to the circuit board of an adjacent valve. Connect the battery plug from the adjacent working valve to the problem valve. Wait for ten seconds. Activate the problem station s sensor ten times. The station should turn on. If the station turns on, and cycles normally, replace the battery. Cause: Solution: Faulty sensor eyes. Test station to determine cause; replace sensor eyes if required. Disconnect the sensor cable from the circuit board of the problem valve. Disconnect the sensor cable from the circuit board of an adjacent working valve. Connect the sensor cable from the adjacent working valve to the problem valve. Activate the problem station s sensor. The station should turn on. If the station turns on and cycles normally, replace the sensor eyes. OPEN VALVE Cause: Solution: Faulty solenoid valve. Test station to determine cause; replace solenoid valve if required. Remove the screw, circuit board and standoff from the problem valve. Remove the battery holder. With a good working battery, briefly contact the solenoid valve directly with the battery as shown in Open Valve figure to right. The contact should cause the valve to open. With the battery holder removed, briefly contact the solenoid valve with the battery in the position shown in Closed Valve figure to right. This should cause the valve to close. If the valve does not operate when directly contacted with a good battery, and the solenoid valve has already been cleaned as outlined at the beginning of this troubleshooting section, replace the solenoid valve. If problems persist: Pass your hand in front of the problem station, while at the same time looking to see if the indicator light on the circuit board flashes (the indicator light is located near the hole in the circuit board where the standoff is mounted). If it does not flash, and the battery and sensor eyes have already been tested as outlined above, the problem may be with the circuit board. Make a note of the numbers printed on the circuit board, then contact your Bradley representative for assistance. CLOSED VALVE 9//0 Bradley - Rev. J; ECN -00-0

15 Parts and Service Terreon Multi-Fount Washfountains TouchTime (TT) - Sprayhead (V Plug-In Transformer) 0 9 Parts List - TouchTime (Switch and Sprayhead) Corner Tri Quad Qty Qty Qty S-9B Switch TouchTime 9-90 Window - Sprayhead -9 Threaded Rod 0- Backplate -0 Nut -00BS Lockwasher 9- Fitting Straight (front sprayhead) Fitting Swivel 90 (side sprayheads) 0 R-000-R Tubing /", Red * * * 0 R-000-G Tubing /", Green * * * 0 R-000-B Tubing /", Black * * * 0 R-000-Y Tubing /", Yellow * * * - Spacer 0- Nut, /- 0-0 Spanner Wrench * Specify length in feet. Bradley - Rev. J; ECN //0

16 Terreon Multi-Fount Washfountains Parts and Service TouchTime (TT) Metering Valve - Assembly Black Supply Tube (From Sprayhead) Green Supply Tube (From Sprayhead) 9 0 Red Supply Tube (From Sprayhead) Gray Wires Terminal Block Brown Wires Supply Inlet Black Wires Green Wires Left Button Center Button Right Button Parts List - TouchTime Metering Valve Assembly Corner Tri Quad Qty Qty Qty S-9 TT TMA Dual Valve Assembly (Transformer not Included) - - S-9 TT TL Dual Valve Assembly (Transformer not Included) - - S-9 TT TMA Tri Valve Assembly (Transformer not Included) - - S-99 TT TL Tri Valve Assembly (Transformer not Included) - - S-9 TT TMA Quad Valve Assembly (Transformer not Included) - - S-0 TT TL Quad Valve Assembly (Transformer not Included) - - S0- Navigator Valve, GP 0-9 Bracket, Ganged Valve 9 P-0 Screw 0- x / PN 0 S0-0A Solenoid Valve, VAC, through S0-0 Solenoid Valve, VAC, closed 0- Compression Nut, /" 0- Screw - x / PN S9-0 Adapter, Valve Inlet S- Transformer 9//0 Bradley - Rev. J; ECN -00-0

17 Parts and Service Terreon Multi-Fount Washfountains TouchTime Valve (TT) Assembly - Solenoid Valve S0-0S (closed body) and S0-0AS (thru body) Item Qty. Part No. Description -0 Valve Body, ¼" Closed -0A Valve Body, ¼" Thru 9-9 Diaphragm 9- Armature 9- Spring 9-9 Armature Housing 9-0 Clamp, Armature Housing 9-9 Coil, Solenoid Valve 0- Screw, # x / 9-00CS O-Ring, # Flow Restrictor,. GPM S- Repair Kit 0 9 Problem Cause Solution An individual operating station fails to shut off and drips. Debris is trapped between the diaphragm and the valve seat. Remove debris between diaphragm and the valve seat.. Remove the three # Phillips-head screws that hold the solenoid valve assembly together. Be careful not to lose the armature or spring.. Remove the diaphragm. Remove any particles that have been trapped between the diaphragm and the valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center orifice and both small side orifices are open.. Reassemble in reverse order (do not overtighten the Phillips-head screws or the plastic valve body may crack). Tighten until the armature plate makes contact with the plastic body.. Reconnect the wiring. An individual operating station fails to turn on. A failed coil for the valve or loose electrical connection to the terminal. Test the station to determine the cause.. Disconnect the wires from the coil of an adjacent valve. Disconnect the wires from the problem valve and reconnect to the adjacent valve.. Turn on electrical and water supplies to the unit. Pass your hand in front of the sensor of the problem station, and the adjacent station should turn on. If the adjacent station turns on and cycles normally, replace the coil on the problem valve. If the adjacent valve fails to turn on, inspect the wires from the sensor cable and do the following: make sure there are no breaks and that the fully insulated disconnect terminals are firmly crimped in place; turn off the electrical and water supplies; reconnect to the adjacent valve and turn on the water supplies to the unit; pass your hand in front of the sensor. If the station still fails to turn on, replace the sensor. Bradley - Rev. J; ECN //0

18 Terreon Multi-Fount Washfountains Parts and Service Thermostatic Mixing Valve Troubleshooting Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions: If stop valves are used, make sure that they are fully open. Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or leaking stop valves. Check the hot water heater output to make sure that it is at least 0 F above the set temperature. Problem Cause Solution External leaks. Damaged cartridge or O-rings. Replace cartridge with part number 9-9 Improper water temperature or temperature fluctuation. Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection and repair is complete. Hot water supply is not 0 above desired set point. Valve temperature is not properly set. Increase hot water supply temperature Adjust the temperature.. Loosen the cap screw about /" (- turns) and lift up the cover (do not remove).. Using the cover, turn the cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage the unit. Push the cover down and tighten the screw. Limited water flow. Dirt and debris have built up in the valve or strainer.. Check to make sure both hot and cold supplies are connected to the Navigator mixing valve and that they have water flow.. Remove cover and U-clip. Remove the cartridge and clean the strainer. It is not required to grease cartridge, however if desired, use silicone grease only. Do not use grease on check valves. Parts List Quantity S Cap Screw 0- Cover 9-9 Thermostatic Cartridge 9-0 Check Valve* -0 Retaining Ring* -9 Valve Body -09 U-Clip * Included with Prepack S- Tempered Line Adapter Option Part no. S9-0 (replaces S9-000 if tempered line is used) Strainer (-0) 9//0 Bradley - Rev. J; ECN -00-0

19 Parts and Service Terreon Multi-Fount Washfountains Soap System Parts List - Soap Valve S09-0 Qty S09-0 Soap Valve Complete S-09 Plunger Assembly 0-A Collar 0-9 Set Screw - O-Ring 9-0 Seat Assembly -09 Spring -0M Cylinder R-0000 Tube /" ID (Specify Length in Feet) Qty 0-00 Soap Tank 9-99 Hose / ID * -00 Hose Clamp 9-9 Male Fitting 0-09 Nut 0-00CJ Washer - Filler -0 Soap Filler Cap 9 R-00 Tube Vent / * 0-09 Soap Tank Cap 9- Bulkhead Fitting R-0000 Tube Supply / * 9- Tee 0- Nut -00CB Washer S-09 Soap Valve Body Assembly S09-0 Soap Valve 0- Soap Filler Cap Wrench 9-0 Nut 0-00AV Washer 9- Ferrule R-000 Tube * S0-09 Complete Soap System (incl. items -) Bradley - Rev. J; ECN //0 9

20 Terreon Multi-Fount Washfountains Parts and Service Soap System Soap Recommendations Quality soap dispensers require good quality soap and periodic maintenance to properly operate. Bradley soap dispensers will provide dependable, consistent operation over the long term when soap with reasonable viscosity and ph levels are used and when a minimal amount of periodic maintenance is performed on the valves. Soap thickness is determined by a measurement called viscosity. Soap viscosity should be between 00 cps (centerpoise) and 00 cps for all Bradley soap dispensers. Thinner soaps are perceived by the users as being "watered down" so users tend to take more than they need, resulting in waste. Thick soaps flow slower and inhibit the "flushing" action of the valves, which allows the soap to congeal in the valve and cause clogs. The ph (acid) level of the soap should be in the range of. to.. More acidic soaps (ph levels lower than.) will corrode metal parts (even stainless steel!!) and degrade rubber and plastic components. They will also cause skin irritation. Most inexpensive soaps (typically the pink lotion type) fall into this acidic category and will eventually cause valve failure and metal corrosion. Base soaps (ph levels higher than.) will cause swelling or degradation of rubber and plastic parts and skin irritation. Generally, any quality soap meeting the viscosity and ph guidelines above will work well with Bradley soap dispensers. PCMX or Isapropanol based antibacterial soaps (within viscosity and ph limits) will also work with Bradley dispensers. Soaps satisfying these basic guidelines will provide consistent flow and reduce clogs. Most soap dispenser problems are caused by soap that is too thick or corrosive, or by a lack of maintenance. Many soaps come in concentrate form which must be diluted with water. Often, the soap is improperly diluted or used straight out of the bottle, which causes clogging and valve failure. If proper soap is being used, valves that have never been cleaned are usually the source of dispensing problems. Bradley has entered into an agreement with Champion Brand Products to provide additional customer service for purchasers of our dispensers regarding soap issues. They are very helpful and can get to the bottom of almost any soap dispenser related problem. They also sell an excellent "Bradley approved" soap. Please see Soap Instruction Sheet - for details about soap valve cleaning or how to contact Champion. With proper maintenance and soap, Bradley dispensers will provide long term, trouble free operation. Soap Dispenser Maintenance Instructions for Multi-Fount Washfountains Bradley soap dispensers will provide dependable, consistent operation over the long term when the proper soap is used and when a minimal amount of periodic maintenance is performed on the valves. Valves must be maintained (cleaned) to function properly. To ensure proper operation of your soap dispenser, follow these instructions: Once per month, remove the cap from the soap tank and insert the draw tube (below the cap) into hot water and soak it for 0 minutes. Push valve at least 0 times while it is soaking. Flush soap reservoir with hot water while valve is soaking. In cases of extreme clogging, the valve should be disassembled and the parts should be soaked in hot water or cleaning solution to restore proper functioning. Soap dispensers that will not be used for extended periods of time (schools during summer break, etc.) should be drained, cleaned and left empty until put back into service. Soap left on the outside of dispensers can cause discoloration and corrosion of the reservoir (even on stainless steel units). All soap should be wiped or scrubbed off daily, then the outside of the dispenser should be rinsed with clear water and dried with a soft cloth. 0 9//0 Bradley - Rev. J; ECN -00-0

21 Parts and Service Terreon Multi-Fount Washfountains Drain Spud and Strainer Spud Washer (part of Item ) Washfountain Bowl Parts List Spud Locknut (part of Item ) Qty -0 Dome Strainer 0- Screw 0- x /" (for strainer) -09 Drain Spud (includes washer & nut) The rubber washer that comes with this kit is used for certain applications. Discard this washer for this application as it is not used on washfountains. Floor Pedestal - Assembly Corner Tri Quad Qty Qty Qty -9 Mounting Panel Mounting Panel - - ** S0-0 Upper Bracket Assembly - ** S0-0 Upper Bracket Assembly Lower Bracket Lower Bracket Screw /-0 x / -00BJ Washer -0 Clip S0-00 Access Panel - Standard Height - S0-09 Access Panel - Juvenile Height - S0-0 Access Panel - Standard Height - - S0-09 Access Panel - Juvenile Height - - * -0 Washer *9-09 Screw 9 * Access panel (Item ) part numbers include the screw and washer. ** Upper Bracket Assembly includes Item. Bradley - Rev. J; ECN //0

22 Terreon Multi-Fount Washfountains Parts and Service Wall Mount Pedestal - Assembly Corner Tri Quad Qty Qty Qty S- Pedestal Assembly - - S-0 Pedestal Assembly - - * 0-9 Screw /-0 - * P0- Screw 0- - * -0 C;o[ - S0-0 Access Panel - Standard Height - - ** -09 Screw - ** -0 Washer - * Pedestal assembly (item ) part numbers include the screws and clip ** Access panel (item ) part numbers include the screw and washer Sprayhead Cover Attaching Hardware Corner-Fount Tri-Fount Quadra-Fount Parts List - Sprayhead Cover Attaching Hardware Corner Tri Quad Qty Qty Qty 9- Anchor Bar Threaded Rod /-0 x " -0 Wing Nut /-0-90 Guide Tube Support Tube Anchor Bar - - 9//0 Bradley - Rev. J; ECN -00-0

23 Parts and Service Terreon Multi-Fount Washfountains Sprayhead Covers - Replacement Parts Parts Numbers - MF9 Corner Fount Color Covers Color Covers Arctic Chip S0-0AD Lannonstone S0-0S Bluesky S0-0AL Landon Gray S0-0AP Charcoal S0-0K Mountain Top S0-0AN Cobblestone Coffee Bean Cornfield S0-0T S0-0AJ S0-0AK Mystic Moss Organic Taupe Peppered White S0-0AG S0-0AR S0-0E Contact Bradley for bowl part numbers. Empire Gray S0-0 Graphite S0-0P Hillside S0-0AM Jade S0-0N Riverstone Stardust Summer Sage White Sand S0-0AF S0-0AH S0-0AE S0-0W Parts Numbers - MF9, MF99 Tri-Fount Color Covers Arctic Chip S0-0AD Bluesky S0-0AL Charcoal S0-0K Cobblestone S0-0T Coffee Bean S0-0AJ Cornfield S0-0AK Empire Gray S0-0 Graphite S0-0P Hillside S0-0AM Jade S0-0N Color Lannonstone Landon Gray Mountain Top Mystic Moss Organic Taupe Peppered White Riverstone Stardust Summer Sage White Sand Covers S0-0S S0-0AP S0-0AN S0-0AG S0-0AR S0-0E S0-0AF S0-0AH S0-0AE S0-0W Parts Numbers - MF9, MF99 Quadra-Fount Color Covers Arctic Chip S0-0AD Bluesky S0-0AL Charcoal S0-0K Cobblestone S0-0T Coffee Bean S0-0AJ Cornfield S0-0AK Empire Gray S0-0 Graphite S0-0P Hillside S0-0AM Jade S0-0N Color Lannonstone Landon Gray Mountain Top Mystic Moss Organic Taupe Peppered White Riverstone Stardust Summer Sage White Sand Covers S0-0S S0-0AP S0-0AN S0-0AG S0-0AR S0-0E S0-0AF S0-0AH S0-0AE S0-0W Bradley - Rev. J; ECN //0

24 Terreon Multi-Fount Washfountains Parts and Service Pedestal Panels Parts List - Sprayhead Cover Attaching Hardware Color Wall Mounted Left Panel Wall Mounted Right Panel Juvenile Height Left Panel Juvenile Height Right Panel Standard Height Left Panel Standard Height Right Panel Arctic Chip S-AD S-AD S-AD S-AD S-9AD S-0AD Bluesky S-AL S-AL S-AL S-AL S-9AL S-0AL Charcoal S-K S-K S-K S-K S-9K S-0K Cobblestone S-T S-T S-T S-T S-9T S-0T Coffee Bean S-AJ S-AJ S-AJ S-AJ S-9AJ S-0AJ Cornfield S-AK S-AK S-AK S-AK S-9AK S-0AK Empire Gray S- S- S- S- S-9 S-0 Graphite S-P S-P S-P S-P S-9P S-0P Hillside S-AM S-AM S-AM S-AM S-9AM S-0AM Jade S-N S-N S-N S-N S-9N S-0N Lannonstone S-S S-S S-S S-S S-9S S-0S London Gray S-AP S-AP S-AP S-AP S-9AP S-0AP Mountaintop S-AN S-AN S-AN S-AN S-9AN S-0AN Mystic Moss S-AG S-AG S-AG S-AG S-9AG S-0AG Organic Taupe S-AR S-AR S-AR S-AR S-9AR S-0AR Peppered White S-E S-AE S-E S-E S-9E S-0E Riverstone S-AF S-AF S-AF S-AF S-9AF S-0AF Stardust S-AH S-AH S-AH S-AH S-9AH S-0AH Summer Sage S-AE S-AE S-AE S-AE S-9AE S-0AE White Sand S-W S-W S-W S-W S-9W S-0W S- S- S-9 9//0 Bradley - Rev. J; ECN -00-0

25 Parts and Service Terreon Multi-Fount Washfountains Bowl - Assembly Parts List - Bowl Assembly Corner Tri Quad Qty Qty Qty 0-0 Bolt -00CG Washer 0-0 Bracket 00-0 Plate -00CH Lockwasher -0 Nut Bradley - Rev. J; ECN //0

26 Terreon Multi-Fount Washfountains Parts and Service Terreon Cleaning and Maintenance Material Description: Terreon is an NAHB Certified densified solid surface material composed of polyester resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household cleaner such as Formula 09 or Windex. Stubborn Stains: Remove tough stains with Ajax, Comet, or Soft-Scrub and a green Scotch-Brite pad or lightly sand in a circular motion with 0 grit wet/dry sandpaper. The finish can be renewed with a maroon Scotch-Brite pad. Special Situations for Material Scratches: Remove scratches with a green Scotch-Brite pad. The finish can then be renewed with a maroon Scotch-Brite pad. Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit thoroughly after cleaning. Restoring the surface: Use Hope s Solid Surface cleaner and polish to refresh and protect the Terreon Solid Surface material. Bradley recommends additional care and maintenance for the darker colored Terreon. For complete instructions on this additional maintenance see Bradley document #0. Do not use strong acid or alkaline chemicals and cleansers to clean Terreon. If these chemicals come in contact with the Terreon surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects. Repair Kits: Terreon repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 0 days. Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. When cleaning units equipped with infrared (electronic eye) activation, it is helpful to turn off the power to the unit or cover the windows to prevent accidental activation. After the window is covered, the water will run for approximately 0 seconds and then shut off. 9//0 Bradley - Rev. J; ECN -00-0

Installation HSL1/IR HSL1/BIR3. Ligature Resistant Single-Station Lavatory. Table of Contents

Installation HSL1/IR HSL1/BIR3. Ligature Resistant Single-Station Lavatory. Table of Contents HSL1/IR HSL1/BIR3 Ligature Resistant Single-Station Lavatory Table of Contents Supplies Required.... 2 Components.... 3 Dimensions... 4-5 Rough-Ins... 6 Bowl Mounting with In-Wall Carrier.... 7 Bowl Mounting

More information

Installation. SS-1N (bowl only) SS-1N Infrared SS-1N Battery Infrared SS-1N Touch Time. Table of Contents. Express Lavatory System SS-Series

Installation. SS-1N (bowl only) SS-1N Infrared SS-1N Battery Infrared SS-1N Touch Time. Table of Contents. Express Lavatory System SS-Series SS-1N (bowl only) SS-1N Infrared SS-1N Battery Infrared SS-1N Touch Time Express Lavatory System SS-Series SS-1N with TouchTime activation, shown with optional polymer access panel Express Lavatory Systems

More information

Parts & Service. Sentry Washfountain Discontinued Models Prior to February 1, SN " Semi-Circular, Floor-Mounted

Parts & Service. Sentry Washfountain Discontinued Models Prior to February 1, SN  Semi-Circular, Floor-Mounted SN00 (AST shown) SN00 (AST shown) SN0 (AST- shown) SN0 (IR shown) SN00 (AST-F shown) SN00 (AST shown) SN0 (IR shown) Parts & Service Discontinued Models Prior to February, 0 SN00 " Semi-Circular, Floor-Mounted

More information

Installation Instructions

Installation Instructions CRS-3/IR/LSD Installation Instructions Express Crescent Lavatory System CRS-Series Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications. A DA C O M PLIA NT TAS Table of Contents

More information

Installation MF2933/TT

Installation MF2933/TT Terreon Tri-Fount Washfountain with TouchTime Control (Standard*, Juvenile and OC Height) * Standard Height is D/TS Compliant Table of Contents Pre- Information... 2 Parts Included with the Tri-Fount...

More information

Installation MF2939/AST4

Installation MF2939/AST4 Terreon Tri-Fount Wall-Hung Washfountain with Air Valve (Standard*, Juvenile* and O Height) * Standard and Juvenile Height are ADA/TAS ompliant Table of ontents Pre- Information... 2 Parts Included with

More information

Sentry Washfountain Parts & Service Guide

Sentry Washfountain Parts & Service Guide Sentry Washfountain Parts & Service Guide Discontinued Models Prior to May, 00 1-1 Rev. A; EN 0-011 00 Bradley Corporation Page 1 of -1-00 P.O. Box 09, Menomonee Falls, WI 0-009 TEL. 1-00-Bradley FAX -1-1

More information

Installation. SS-1N (bowl only) SS-1N/IR SS-1N/BIR3 SS-1N/TT. Express Lavatory System SS-Series. Table of Contents

Installation. SS-1N (bowl only) SS-1N/IR SS-1N/BIR3 SS-1N/TT. Express Lavatory System SS-Series. Table of Contents SS-1N/IR Express Lavatory System shown with optional acrylic trap cover SS-1N (bowl only) SS-1N/IR SS-1N/BIR3 SS-1N/TT Express Lavatory System SS-Series Patent Pending ADA CO MPLIANT SS-1N/TT Express Lavatory

More information

WARNING NOTICE IMPORTANT

WARNING NOTICE IMPORTANT Installation WF2605 WF2500 Series Terreon Classic WF2600 Series Terrazzo WF2700 Series Stainless Steel WF2800 Series Bradstone WF3200 Series Terreon Deep Bowl TDB3100 Series Terreon Deep Bowl WF3203 WARNING

More information

Installation. MG-2 Infrared. Express Lavatory System - MG Series with Adaptive Infrared. Table of Contents

Installation. MG-2 Infrared. Express Lavatory System - MG Series with Adaptive Infrared. Table of Contents Installation Express Lavatory System - MG Series with Adaptive Infrared Table of Contents Pre-Installation Information...2 Supplies Required...2 Dimensions...3 Supplies Required...3 Rough-Ins...4 Mount

More information

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control Aerada 00 Series Futura With Accu-Zone (AZ) Infrared Control S3-3 S3-3TL..." Centerset S3-3TMA... " Centerset w/ TMV S3-3..." Centerset, no Solenoid Valve S3-33TL...Centershank S3-33TMA... Centershank

More information

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain S93-572 S93-573 S93-572 ST4 S93-573 TT S93-574 IR Stainless Steel Wall-Hung radmate Washfountain S93-574 (Standard* & Juvenile Height) * Standard Height is D Compliant Table of Contents Supplies Required...

More information

Installation MF2922/BIR3

Installation MF2922/BIR3 Terreon orner-fount Washfountain with attery Operated Infrared ontrol (Standard, Juvenile and O Height) Table of ontents Pre- Information... 2 Parts Included with the orner-fount... 3 Instructions... 4-8

More information

WARNING NOTICE IMPORTANT

WARNING NOTICE IMPORTANT Installation WF2605 WF2500 Series Terreon Classic WF2600 Series Terrazzo WF2700 Series Stainless Steel WF2800 Series Bradstone WF3200 Series Terreon Deep Bowl TDB3100 Series Terreon Deep Bowl WF3203 WARNING

More information

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain S93-572 S93-573 S93-572 ST4 S93-573 TouchTime S93-574 Infrared Stainless Steel Wall-Hung radmate Washfountain S93-574 (Standard* & Juvenile Height) * Standard Height is D Compliant Table of Contents Supplies

More information

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control BRADLEY SC A S53-141 4" Centerset S53-148 4" Centerset, no Solenoid Valve S53-186 4" Centerset with 8" Trim Plate S53-285 Centershank

More information

Installation Instructions

Installation Instructions Instructions Aerada 900 Series Futura Faucet With Battery (BIR) Infrared Control S53-284 4" Centerset/Centershank S53-289 Centerset/Centershank w/plate Table of Contents Pre- Information............2 900

More information

Installation Instructions

Installation Instructions Installation Instructions WF2603, WF2604 Terrazzo WF2703, WF2704 Stainless Steel WF2603 Classic Semi-Circular 36"/54" Washfountain with Touch Time Control WF2703 IMPORTANT Read this entire installation

More information

Operation and Service Guide: Showers

Operation and Service Guide: Showers Metering Air Valve For Column Showers (1998-2000) Version 1/8" O.D. Air Tubing R68-600008 (Specify Length 269-881 Elbow S07-062A Air valve, See Sheet 3 for Parts Information 169-215 3/8" x 1/4" Reducer

More information

Installation Instructions

Installation Instructions Instructions Aerada 90-75 Series Metering Faucet S53-053 90-75 Series Metering Faucet with 4" Centerset S53-082 90-75 Series Metering Faucet with 4" Centerset & 8" Trim Plate S53-058 90-75 Series Metering

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Stainless Steel 180 (WWF Series) Electronic Washfountains Infrared and Piezo Pushbuttons WWF-3603-4204-5404 36", 42" and 54" 3 and 4 Station Units MADE IN THE U.S.A. (317)

More information

Installation For Service Only

Installation For Service Only For Service Only IMPORTANT! Aerada 1100 Series Low Arc Faucet S53-302 Battery Infrared Metering Faucet (Center Shank with 4" Trimplate) THIS SIDE UP! Packing List Read this entire installation manual to

More information

Installation. ABP-1C TouchTime Ablution System IMPORTANT! Table of Contents Rev. B; ECN E 2014 Bradley Page 1 of 5 10/6/2014

Installation. ABP-1C TouchTime Ablution System IMPORTANT! Table of Contents Rev. B; ECN E 2014 Bradley Page 1 of 5 10/6/2014 ABP-1C TouchTime Ablution System Rear Mount Table of Contents Pre- Information... 2 Rough-Ins... 2 3... 4 Cleaning and Maintenance... 5 Front Mount IMPORTANT! Read this entire installation manual to ensure

More information

Installation Instructions

Installation Instructions Installation Instructions AquaFount Deep Bowl Washfountain WAF-5408/5406 Floor Mounted 360 Infrared/Pneumatic/Piezo MADE IN THE U.S.A. Page 2 Step One: Pedestal Mounting Parts supplied: Pedestal (pre-assembled)

More information

HSL1 SafeCare Ligature-Resistant Single-Station Lavatory

HSL1 SafeCare Ligature-Resistant Single-Station Lavatory Ligature-Resistant Design D, NSI, TS and UFS Compliant Constructed of Vandal-Resistant Terreon Solid Surface Material vailable in a variety of colors Choose Terreon or Terreon RE Mount with Optional Surface

More information

Installation Instructions

Installation Instructions Installation Instructions AquaFount-90 Corner Mounted Washfountain WAF-2200 Series Infrared/Pneumatic/Piezo MADE IN THE U.S.A. Page 2 Step One: Pedestal Mounting Parts supplied: Pedestal (pre-assembled)

More information

WARNING NOTICE IMPORTANT

WARNING NOTICE IMPORTANT Installation WF2605 WF2500 Series Terreon Classic WF2600 Series Terrazzo WF2700 Series Stainless Steel WF2800 Series radstone WF3200 Series Terreon Deep owl TD3100 Series Terreon Deep owl WF3203 WRNING

More information

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED HAND WASHING FAUCETS EBF-750 I.I. Code No. 0816324 EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets Includes Instructions

More information

MG-3 Express Lavatory System MG-Series

MG-3 Express Lavatory System MG-Series D and TS Compliant Serves One to Three Users at a Time Standard Lavatory Spacing on 30" Centers Continuous Bowl, Sprayhead and End Caps are Constructed of Terreon or Terreon RE Solid Surface Material vailable

More information

Installation Instructions

Installation Instructions Installation Instructions Front-Mounted Barrier Free Rectangular Bowl Stainless Steel Lav A DA C O M PLIA NT Table of Contents Pre-Installation Information.................... 2 Rough-Ins..................................

More information

Installation Instructions

Installation Instructions Installation Instructions AquaWave Washfountain 1, 2 and 3 Station WAW-2311, WAW-2322, WAW-2333 Infrared/Pneumatic/Piezo MADE IN THE U.S.A. Page 2 Installation notice! Check Rough-in location and flush

More information

Installation Instructions

Installation Instructions Installation Instructions Individual Built-In Wall Shower with Concealed Supplies Table of Contents Pre-Installation Information...2...3 Repair parts...4 Metering Valve Troubleshooting...5 Cleaning and

More information

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT Installation erada 1200 Series CS Faucet S53-325 Battery-Operated Capacitive Sensing Gooseneck Faucet Centershank with 4-inch Trim Plate (Optional: 8-inch or No Trim Plate) Table of Contents Supplies Required..................

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Aquawave (WAW Series) Electronic Washfountains Infrared and Piezo Pushbuttons WAW2311, WAW2322, WAW2333 1, 2 and 3 Station Units MADE IN THE U.S.A. (317) 875-0830 Fax: (317)

More information

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2 NPT Brass Pipe Plug Adjustable Wrench IMPORTANT! Bradley TMVT1 Thermostatic Mixing Shower Valve ASSE 1016 & UPC Certified For use with shower heads rated at 9.5 L/min (2.5 gpm) or higher. Supplies Required Teflon Tape Allen Key Wrenches Screwdriver Brass

More information

Tools Needed for Mounting Cleá Filling Station

Tools Needed for Mounting Cleá Filling Station ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED ON THE LABEL. ALWAYS DISPENSE INTO APPROVED

More information

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer SCS 2 BLACK SHADOW SERIES 3.1 DISPENSER ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED

More information

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800 SPEAKMAN COMPANY 1of 18 S-9100, S-9200, S-9300, S-9400, S-9700, S-9800 Series Installation, Maintenance & Operation Instructions SENSORFLO BATTERY or AC POWERED SLIM DESIGN FAUCETS with DIFFERENT OPTIONS

More information

Outdoor Bottle Fillers

Outdoor Bottle Fillers Outdoor Bottle Filler Pedestal Mounted Sensor/Pushbutton Activation M-OBF4 / M-OBFM4 TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.51.360 Technical Assistance Fax: 1.626.855.484 NOTES TO INSTALLER:

More information

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer INSTALLATION GUIDE KPF-21 Single Lever Kitchen Faucet With Pull-Out Sprayer www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. August 7, 2017 Congratulations on the purchase of your

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS BEALE ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL MERIDIAN MODEL 3791-RO MODEL# 3791-RO-1-SO-DV RIGHT SIDE OFF-SET CONFIGURATION CORTERRA ADA-COMPLIANT KURVE SINGLE BASIN TABLE OF CONTENTS Prior to Installation....................................... 2

More information

Optima ETF-600/ETF-610

Optima ETF-600/ETF-610 Optima ETF-600/ETF-610 4B ETF-610 1C 4A 5 6 7 7 6 ETF-600 1A 1C PARTS LIST ETF-600 AND ETF-610 FAUCETS Item No. Code No. Part No. Description 1A. 065086 ETF-54-A Faucet and Sensor Assembly (ETF-600). 065117

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS AVERY ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3800V 3900V All Piston (F) 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Standard

More information

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS The 633GAP Series Blend Center modular design lets you easily couple together any number of stations to create a system that meets your specific needs. Mix and match both high and low flow units for filling

More information

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS Body Specifications 236 Protecting your vehicle from corrosion 237 Washing and waxing 238 Cleaning the interior 239 235 SPECIFICATIONS DIMENSIONS AND WEIGHT

More information

Installation Instructions

Installation Instructions CADET Centerset Lavatory Faucet with Speed Connect Drain Installation Instructions Congratulations on purchasing your American Standard faucet with the Speed Connect Drain, a feature found only on American

More information

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST 1A 1B 8 EAF-100/150 I.I. Rev. 0a (11/02) Code No. 0816542 INSTALLATION INSTRUCTIONS ELECTRONIC, SENSOR OPERATED LAVATORY FAUCETS EAF-150 Series Battery Powered Sensor Operated Lavatory Faucets 2 3 7 10

More information

2-DOOR LAUNDRY CABINET KIT

2-DOOR LAUNDRY CABINET KIT 2-DOOR LAUNDRY CABINET KIT OWNER S MANUAL QL055 # 6725161 Table of Contents Table of Contents...2 Safety Information...2 Warranty...3 Warranty Claim Procedure...3 Pre-Installation...4 Tools/Materials Required...4

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Faucets Cast Spout and Gooseneck Spout Certified to comply with ASME A.8. 0 American Standard 0X.0 0X. MODEL NUMBERS 0X.0 0X. 0X.0 0X. CAUTION: Use only

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Optional 0P00.XXX, " Deck Plate Optional 0P800.XXX, 8" Deck Plate Certified to comply with ASME A.8. 0 AS America, Inc. MODEL

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules. 9-1 Section 9 NOTE: This section applies to applicators with CF200PAD right-angle modules. Table of Contents.................................................... 9-1 Introduction................................................

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No. 0816407 Rev. 5 (05/16)

More information

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser INSTALLATION GUIDE Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser KPF-1702 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations

More information

Advisory Bulletin. TB-99 Cleaning and Maintenance For Bobrick B-824 or B-828 Automatic Counter-Mounted Soap Dispensers B-824 B-828

Advisory Bulletin. TB-99 Cleaning and Maintenance For Bobrick B-824 or B-828 Automatic Counter-Mounted Soap Dispensers B-824 B-828 Advisory Bulletin TB-99 Cleaning and Maintenance For Bobrick B-824 or B-828 Automatic Counter-Mounted Soap Dispensers Quality soap dispensers require good quality soap and periodic maintenance to properly

More information

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS 1) PARTS INCLUDED: A. Cleaning Station. B. 3 ea. 3/8" OD x 8' long vinyl chemical supply tubing w/ cap adapter C. 1 ea. 3/4"

More information

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser INSTALLATION MANUAL Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser KPF-1702 www.kraususa.com I toll free: 1.800.775.0703 I 2014-2015 Kraus USA Inc. I REV. August 16, 2016 Thank you

More information

Installation Instructions

Installation Instructions Installation Instructions Thermostatic Valve and Trim Model No. RH-5944 1 REV.A Restoration Hardware Product Size Specification Diagram General Characteristics In case of instantaneous heaters, hot water

More information

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL MERIDIAN MODEL 3792 CORTERRA ADA-COMPLIANT KURVE DUAL BASIN TABLE OF CONTENTS Prior to Installation....................................... 2 Accessibility Overview.................................... 3

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MODEL: GRAFTON RH-510 1 REV.A Restoration Hardware Balance Pressure Tub /Shower Set Specification Diagram Ensure that the stop ring () is correctly installed, prior to finished

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Infection Control Faucet 0 / 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M

More information

ETF-600 Sensor Operated Lavatory Faucet

ETF-600 Sensor Operated Lavatory Faucet INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED LAVATORY FAUCET ETF-600 I.I. Code No. 0816318 ETF-600 Sensor Operated Lavatory Faucet Includes Instructions for Installation of Optional Back Checks

More information

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust INSTRUCTION MANUAL NOTE TO INSTALLER : PLEASE GIVE THIS MANUAL TO THE CUSTOMER AFTER INSTALLATION. AUTOMATIC FAUCET Important Safeguards Precautions Model Number and Components Before Use How to Use How

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Moments Proximity Faucets MODEL NUMBERS 0.X 0.X 0B.0X CAUTION: Use only American Standard supplied cable sets. Using non-as supplied cables, or cutting, splicing or

More information

Installation Instructions Series

Installation Instructions Series PORTSMOUTH MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Series 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature

More information

G SERIES - E TOUCH MIXER / TAP

G SERIES - E TOUCH MIXER / TAP PLUMBERS Installation and maintenance INSTRUCTIONS G SERIES - E TOUCH MIXER / TAP electronically operated MIXER / TAP G Series E Touch Basin Tap G Series E Touch Basin Mixer 1 IS1301C (03/15) INDEX 3 IMPORTANT

More information

Installation Instructions

Installation Instructions BERWICK / BOULEVARD MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature

More information

PeroxiDraw Dispenser

PeroxiDraw Dispenser The PeroxiDraw Dispensing System is a locking dispensing system that allows the user to dispense Green Earth Peroxide Cleaner for up to six different dilutions and applications safely and effectively.

More information

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP 1. PARTS: ITEM DESCRIPTION QTY. A. Blend Center Assembly 1 B. ¼ ID X 8 Long Vinyl Supply Tubing & Foot Valve Assembly 1 C. Ceramic Weight 1 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 4 GPM Station Only)

More information

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY NAVAL NAVAL I.I. Code No. 0816176 Rev. 1 INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS Certified Made in the U.S.A Exposed Closet Flushometer 1-1/2" Top

More information

LIGATURE RESISTANT SENSOR FAUCET

LIGATURE RESISTANT SENSOR FAUCET LIGATURE RESISTANT SENSOR FAUCET PATENT #US D635, 386 #SF370/SAL-5011 INSTALLATION, MAINTENANCE & OPERATION INSTRUCTIONS SENSORFLO BATTERY OR AC POWERED The Ligature Resistant Sensor Faucet was designed

More information

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5 HANDS-FREE WALL MOUNTED SINKS AC OR BATTERY POWERED 1 Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5 Columbia does not recommend use

More information

Backpack Sprayer. Use and Care Manual

Backpack Sprayer. Use and Care Manual Backpack Sprayer Use and Care Manual BACKPACK SPRAYER CAUTION: Read and follow all instructions Do Not Return This Backpack To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead

More information

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed

More information

SECTION 4 - FUEL/LUBRICATION/COOLING

SECTION 4 - FUEL/LUBRICATION/COOLING For Arctic Cat Discount Parts Call 606-678-9623 or 606-561-4983 SECTION 4 - FUEL/LUBRICATION/COOLING 4 TABLE OF CONTENTS Carburetor Specifications... 4-2 Carburetor Schematic... 4-2 Carburetor... 4-3 Cleaning

More information

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS 1. PARTS CHECKLIST: ITEM DESCRIPTION QTY. A. Blend Center Assembly 1 B. ¼ ID X 8 Long Vinyl Supply Tubing & Foot Valve Assembly 4 C. Ceramic Weight 1 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 1 GPM Station

More information

WARNING Carefully Read These Instructions Before Use

WARNING Carefully Read These Instructions Before Use DO NOT RETURN THIS SPRAYER TO STORE Call: 1-800-950-4458 Backpack Sprayer Use and Care Manual Manufactured for Northern Tool + Equipment Co., Inc. WARNING Carefully Read These Instructions Before Use Model

More information

NILFISK BA 500 Service Manual

NILFISK BA 500 Service Manual NILFISK BA 500 Service Manual Model 66324400 12/94 Form Number 043023 TABLE OF CONTENTS Batteries...21 Brush Drive Belt Adjustment Or Replacement...7 Brush Drive Motor - Carbon brush Inspection... 8 Brush

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Certified to comply with ASME A.. 0 American Standard Optional 0P00.XXX, " Deck Plate Optional 0P00.XXX, " Deck Plate 0.

More information

INSTALLATION INSTRUCTIONS PATIENCE

INSTALLATION INSTRUCTIONS PATIENCE INSTALLATION INSTRUCTIONS PATIENCE 706.8X DUAL CONTROL WIDESPREAD LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure

More information

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.80 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation

More information

Installation Instructions 7024

Installation Instructions 7024 HAMILTON Centerset Lavatory Faucet with EverClean Finish & Speed Connect Drain Installation Instructions 70 Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Bariatric Lavatory BHS-3123 Table of Contents Pre-Installation Information...3 Physical Dimensions...4 Rough-In Dimensions...5 Mounting Dimensions...6 Checking Contents...7

More information

Air Operated 1:1 Oil Ratio Pump OP-11

Air Operated 1:1 Oil Ratio Pump OP-11 INSTRUCTION MANUAL Air Operated 1:1 Oil Ratio Pump OP-11 Congratulations on purchase of this World Class Air Operated Oil Ratio Pump! S1221, Rev C World-class Industrial Oil Dispensing pumps with guaranteed

More information

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec. 10000005389 (I) Mat. 10064383 Doc. 10064383 REGULATOR COMPONENTS Item Part No. Description 1 MASK MOUNTED REGULATOR ASSEMBLY

More information

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE 05 September 018 TABLE OF CONTENTS PRE-INSTALLATION INFORMATION PRE-INSTALLATION INFORMATION 3 PACK CONTENTS 4 TECHNICAL

More information

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM This filter system is designed for use with aboveground and semi-inground swimming pools. DO NOT operate this filter system without adding D.E. as it will cause

More information

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0. HANDS-FREE FLOOR MOUNTED WASH STATIONS AC OR BATTERY POWERED 1 Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.5

More information

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body SERVICE PROCEDURES AND SPECIFICATIONS Body SECTION 6 5 Specifications........................................... 208 Protecting your vehicle from corrosion...................... 209 Washing and waxing.....................................

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V Part B, Section 1 This section covers the following unit configurations. Model Voltage Pump Manifold Control 3100V 3400V 3500V 3700V All Piston (E) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Standard

More information

High Lift Transmission Jack

High Lift Transmission Jack 655 Eisenhower Drive Owatonna, MN 55060 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales: (507) 455-7223 Fax:

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Wall Mount Electronic Proximity Lavatory Faucet TE: Please refer to R30 Mounting Kit installation instructions #M4 prior to faucet installation. Certified to comply with

More information

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color Blend Safe II Dispensing System is a modular, locking dispensing system that allows user to dispense chemicals safely, control dispenser inventory and has the flexibility in the field to meet changing

More information

Single Lever Pull-Out Kitchen Faucet

Single Lever Pull-Out Kitchen Faucet INSTALLATION GUIDE Single Lever Pull-Out Kitchen Faucet KPF-1621 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations on the purchase of your new Kraus

More information

Air / Hydraulic Floor Service Jack

Air / Hydraulic Floor Service Jack SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales:

More information

Artec Pro Single Handle Commercial Kitchen Faucet

Artec Pro Single Handle Commercial Kitchen Faucet INSTALLATION GUIDE Artec Pro Single Handle Commercial Kitchen Faucet KPF-603 www.kraususa.com I Toll Free:.800.775.0703 I 208 Kraus USA Inc. I REV. Aug 2, 208 Congratulations on the purchase of your new

More information

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF-15300 www.kraususa.com I toll free: 1.800.775.0703 I 2014-2015 Kraus USA Inc. I REV. August 18, 2016 PRIOR TO INSTALLATION Make sure you

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Integrated Faucet with Above-Deck Mixing CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing