EG Series Installation Manual

Size: px
Start display at page:

Download "EG Series Installation Manual"

Transcription

1 EG Series Installation Manual Convenient Micro Connectors (M) speed installation and maintenance Enclosure is fully potted and sealed to eliminate threat of moisture contamination in the wiring and electronics High Intensity red and green LED s indicate electronic switch status Approval Agency Controlled Document. No Changes Authorized Without Prior Agency Approval StoneL 67 US Highway 9 Fergus Falls, MN 67 USA Telephone: (8) Fax: Toll Free in US & Canada: sales@stonel.com Web-site:

2 Eclipse (EG) Model Number Descriptions (Example: EGC6RA) Page Function Enclosure/Approvals Entry Options Visual Indicator Brand Options EG Sensor Modules () SST N.O. Sensors () SST N.C. Sensors () NAMUR Sensors (DIN 9) Bus Communication Modules 9 DeviceNet Communication VCT Module C North American (NEC/CEC) D International (IEC/ATEX) P North American (NEC/CEC) A International (IEC/ATEX) () -pin M Male Connector () -pin M Male Connector () -pin M Female Connector () -pin M Male Connector 6 () -pin M Male Connector () -pin M Female Connector R Red Closed/Green Open G Green Closed/Red Open F Flow Line T Three Way (90 rotation) T Three Way (90 rotation) A StoneL M Metso N Neles -***** Special 9 Foundation Fieldbus VCT Module (Bus Powered Outputs) 9 Foundation Fieldbus VCT Module (VDC Externally Powered Outputs) XX Special Configuration D Red Closed/Green Open N Green Closed/Red Open L Flow Line 9 Modbus Communication VCT Module S T Three Way (90 rotation) 96 AS-i Communication VCT Module T T Three Way (90 rotation) (Standard Addressing Version) X Special 97 AS-i Communication VCT Module (Extended Addressing Version)

3 General Specifications and Ratings Operating Life Unlimited Materials of Construction (User to check the chemical compatibility of the materials used in their process to ensure chemical compatibility) Housing Lexan Polycarbonate Drum Lexan Polycarbonate Fasteners Stainless Steel Triggers & Couplings Stainless Steel Lexan is a registered trademark of General Electric Corporation. Temperature Range -0 C to 80 C (-0 F to 80 F) Enclosure Protection NEMA, X & 6; IP67 Warranty Function Module Five Years Indicator & Triggering Two Years Product Patents,6,96;,67,96 Dimensions - Inches (mm). (60). (60) 0.67 (7) 6.0 () M Micro Connectors

4 Eclipse Basic Mounting and Sensor Setting Mounting to ISO-NAMUR Style Actuators. ( Namur Size & ) Attach Function Module using fasteners provided in the mounting kit and tighten to -0 inch pounds. (Do not over tighten). ( Namur Size and Non-Namur applications ) Attach spacer or bracket to actuator with fasteners provided in the mounting kit and tighten securely. Attach Function Module to spacer or bracket and tighten to -0 inch pounds. (Do not over tighten).. Place the Drive Block into the slot of the actuator shaft. Next, place the Inner Drum over the Drive Block, ensuring the Drive Block goes into the mating recess of the Inner Drum. Now slide both Trigger Adjustment Rings over the Inner Drum (for the Flow Line option, place the yellow flow line bar on top of the Visual Indicator Trigger Assembly). Finally, insert the Drum Fastner (provided with the mounting kit) through the entire Visual Indicator/Trigger Assembly and tighten only a couple of turns into the actuator shaft as to allow the Trigger Adjustment Rings to rotate freely to perform the sensor settings. Ensure the assembly is centered. Sensor Settings. Start with the actuator in the closed position. Ensure the Drum Fastener is loose enough to allow the Trigger Adjustment Rings to rotate. Lift and rotate the lower ring until the stainless steel trigger is in front of the lower bulls-eye on the Function Module (lower trigger activates the Red LED). Rotate the actuator to the open position. Lift and rotate the upper ring until the stainless steel trigger is in front of the upper bulls-eye on the Function Module (upper trigger activates Green LED). For the Flow Line option, lift and rotate the yellow flow line bar on top of the Visual Indicator/Trigger Assembly to indicate desired flow. Securely tighten the Drum Fastener. To adjust simply loosen screw and adjust triggers and indicator to suit your application. LEDs will energize and de-energize when powered, indicating sensor status. Indicator Cover. Install the Visual Indicator Cover. The Cover Alignment Ribs on the Visual Indicator Cover are tapered and cannot be inserted vertically into the mating grooves on the Function Module. Place the Visual Indicator Cover over and as close to the Visual Indicator/Trigger Assembly as possible. When the bottom of the Visual Indicator Cover is flush with the base of the Function Module, slide the Visual Indicator horizontally until the Cover Alignment Ribs fit completely into the mating grooves on the Function Module. Tighten the Visual Indicator Cover securely to the actuator with fastners provided in the mounting kit. (-0 inch pounds. Do not over tighten). Wiring. Control and solenoid wires as connected to the Eclipse Function Module via M micro-connectors as per information located on pages thru 8. Eclipse Function Module Closed Trigger (Red LED) () Function Module Fasteners Visual Indicator Cover* Cover Alignment Ribs * Standard Flow Line Visual Indicator not provided with cover Drive Block () Cover Fasteners Drum Fastener Trigger Adjustment Rings Inner Drum Visual Indicator/Trigger Assembly Open Trigger (Green LED) Flow Line Indicator/Trigger Assembly Open Trigger (Green LED) Flow Line Bar Closed Trigger (Red LED)

5 EG Specifications & Wiring Information Configuration: Indications: EG EG Operating Voltage: Maximum Voltage Drop: Current Ratings: Max Inrush Max Continuous Minimum On Current Leakage Current SST Solid-State Sensors (EG & EG) () Solid State Sensors (Normally Open or Normally Closed) Target On Sensor = LED On Target Off Sensor = LED Off Target On Sensor = LED Off Target Off Sensor = LED On 8- VDC; - VAC 6. 0mA mA.0 VDC/VAC VDC/VAC.0m A <0.mA with DC Voltage <0.mA with AC Voltage To Bench Test a Solid State Sensor Unit: Use StoneL Light Read Tester. Or you may use a VDC or 0 VAC power supply with a series load resistor (K ohm to 6K ohm). Connect to NO and C (EG) or NC and C (EG) male pins. WARNING: FAILURE TO USE A SERIES LOAD RESISTOR WHEN BENCH TESTING WITH A POWER SUPPLY WILL RESULT IN PERMANENT DAMAGE TO THE UNIT. SST Namur Sensors (EG) Configuration: () Namur Sensors (Normally Closed) Indications: Target On Sensor = LED Off Target Off Sensor = LED On Operating Voltage: 6-9 VDC Current Ratings: Target On (LED Off) <.0mA Target Off (LED On) >.0mA Must use intrinsically safe repeater barrier. Namur Sensors conform to EN Standard See Page 9 or Page 0 for Intrinsic Safety Hazardous Location Installation Diagram To Bench Test a Namur Sensor Unit: Use StoneL Light Read Tester or a 6-9 VDC power supply across + and - male pins. No series resistor needed. Pins EG Top + Bottom + Bottom - Top - Pins EG EG Top NO Top NC Bottom NO Bottom NC Bottom Common Bottom Common Top Common Top Common Pins EG6 EG6 Top NO Top NC Bottom NO Bottom NC Solenoid - Solenoid - Solenoid + Solenoid + Top/Btm Common Top/Btm Common N/C N/C N/C Solenoid - Solenoid - Solenoid + Solenoid +

6 EG Specifications & Wiring Information DeviceNet EG Module (EG9) Communication Protocol: DeviceNet I/O: () Discrete Inputs (Sensors) () Discrete Output (Solenoid) Default Address: 6 Bit Assignment: Inputs: ( Bytes) Bit 0 = Input (Red LED; Bottom Sensor) Bit = Input (Green LED; Top Sensor) Bit = Fault Bit (Set when both Input and Input = ) Bits 8- = Not Used Outputs: ( Byte) Bit 0 = Not Used Bit = Output (Solenoid) I/O Messaging: Polling, Cyclic, Change of State Operating Voltage: VDC via DeviceNet network Baud Rates: K, 0K, 00K Output Voltage: VDC Max. Output Current: 60mA Max. Output Power: Watts To Bench Test a DeviceNet Unit: Use VDC power supply across V + (Pin ) and V - (Pin ) of male connector. No series resistor needed. To test communication, a functioning DeviceNet network is required. Pins EG9 Shield V + V- CAN_H CAN_L Pins EG96 Shield V + V- CAN_H CAN_L N/C Solenoid - Solenoid + Foundation Fieldbus EG Module (EG9) Communication Protocol: Foundation Fieldbus I/O: () Discrete Inputs (Sensors) () Discrete Output (Piezo Valve) Function Blocks: DI, DO Channel Reference Channel = DI (Green LED) Channel = DI (Red LED) Channel = DO (OUT ) Operating Voltage: 9- VDC (Foundation Fieldbus Voltage) Max Output Current: 6. VDC. Current limited to ma (Bus Powered). Suitable for StoneL Piezo Valve Indication: Red LED = Bottom Sensor Green LED = Top Sensor See Page and Page for Intrinsic Safety (FISCO) Hazardous Location information and Installation Diagram. See Page for Non-Incendive Field Wiring Apparatus Installation Drawing To Bench Test a Foundation Fieldbus Module: Use VDC power supply across FB - (Pin ) and FB + (Pin ) of male connector. No series resistor needed. To test communication, a functioning Foundation Fieldbus network is required. Pins EG9 FB - FB + N/C Pins EG9 FB - FB + N/C SIM JMPR SIM JMPR Solenoid - Solenoid + 6

7 EG Specifications & Wiring Information Modbus EG Module (EG9) Communication Protocol: Modbus I/O: () Discrete Inputs (Sensors) () Discrete Output (Solenoid) Default Address: 0 Bit Assignment: Inputs: 000= Input (Red LED; Bottom Sensor) 000 = Input (Green LED; Top Sensor) Outputs: 0000 = Not Used 0000 = Output (Solenoid ) Operating Voltage: VDC (The VDC power source should share the same ground reference as the communication line) Baud Rates: 9.6K, 9.K, 8.K Output Voltage: VDC Max. Output Current: 60mA Max. Output Power: Watts To Bench Test a Modbus Unit: Use VDC power supply across V + (Pin ) and V - (Pin ) of male connector. No series resistor needed. To test communication, a functioning DeviceNet network is required. Pins EG9 N/C V + V- BUS + BUS - Pins EG96 N/C V + V- BUS + BUS - N/C Solenoid - Solenoid + AS-Interface EG Module (EG96) Communication Protocol: AS- Interface (AS-i) Configuration: () Discrete Inputs (Sensors) () Discrete Output (Solenoid) Default Address: 00 AS-Interface ID/IO Codes: ID = F; IO = ; ID = F; ID = E Bit Assignment: Inputs: Bit = Not Used Bit = Not Used Bit = (Green LED; Top Sensor) Bit = (Red LED; Bottom Sensor) Outputs: Bit = Not Used Bit = Not Used Bit = Output (Solenoid) Bit = Not Used Operating Voltage: -0 VDC (AS-i Voltage) Output Voltage: VDC Max. Output Current: 60mA Max. Output Power: Watts See Page for Non-Incendive Field Wiring Apparatus Installation Drawing To Bench Test AS-i Module: Use VDC power supply across AS-I + (Pin ) and AS-I - (Pin ) of male connector. No series resistor needed. To test communication, a functioning AS-i network is required. Pins EG96 AS-I + AS-I - Pins EG96 AS-I + AS-I - N/C Solenoid - Solenoid + 7

8 EG Specifications & Wiring Information AS-Interface EG Module (EG97) Communication Protocol: AS- Interface (AS-i) Configuration: () Discrete Inputs (Sensors) () Discrete Output (Solenoid) Default Address: 0A AS-Interface ID/IO Codes: ID = A; IO = ; ID = 7; ID = E Bit Assignment: Inputs: Bit = Not Used Bit = Not Used Bit = (Green LED; Top Sensor) Bit = (Red LED; Bottom Sensor) Outputs: Bit = Not Used Bit = Not Used Bit = Output (Solenoid) Bit = Not Used Operating Voltage: -0 VDC (AS-i Voltage) Output Voltage: VDC Max. Output Current: 00mA Max. Output Power:. Watts See Page for Non-Incendive Field Wiring Apparatus Installation Drawing To Bench Test AS-i Module: Use VDC power supply across AS-I + (Pin ) and AS-I - (Pin ) of male connector. No series resistor needed. To test communication, a functioning AS-i network is required. Pins EG97 AS-I + AS-I - Pins EG97 AS-I + AS-I - N/C Solenoid - Solenoid + 8

9 Installation Diagram for Explosive Atmospheres for Europe EGD or A models approved for Intrinsically Safe Installations: (Ex ia IIC T) EGD or A * *Note: Any Visual Indicator/Trigger Assembly option is approved HAZARDOUS (CLASSIFIED) Ex ia IIC T Intrinsic Safety Barriers (Associated Apparatus) NON-HAZARDOUS (SAFE AREA) Individual Sensor wiring Control Equipment Bottom Sensor Barrier Top Sensor Barrier 6 Shields 7 Intrinsically Safe Ground 8 9 EG Enclosure EG Pin Identifiers Pins EG Top Sensor + Bottom Sensor + Bottom Sensor - Top Sensor - INSTALLATION NOTES Intrinsically Safe Installations: (Ex ia IIC T): EG Entity Parameters: Ui = Vdc; Ii = 0 ma ; Ci = 98 nf; Li =.6 mh; Pi =.0 W The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus when the following is true: Ui >Uo; Ii > Io; Pi > Po; Co > Ci + Ccable, Lo > Li + Lcable.. For Installations in Europe, control room equipment connected to intrinsically safe associated apparatus shall not use or generate more than the marked Um of the associated apparatus.. Installation in Europe shall be in accordance with latest editions of the wiring practices for the country of origin.. For Installations in Europe, the Associated Apparatus must be ATEX approved. Associated apparatus manufacturer's installation drawing must be followed when installing this equipment.. To maintain intrinsic safety, wiring associated with each sensor or solenoid coil wiring must be run in separate cables or separate shields connected to intrinsically safe (associated apparatus) ground. Each Sensor and Solenoid coil shall be wired as separate intrinsically safe circuits. 6. Conduit Grounding - Upon installation verify electrical continuity between conduit and ground terminal. 7. Resistance between Intrinsic Safe Ground and earth ground must be less than.0 ohm. WARNING: 8. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in location where it may be subjected to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should only be done with a damp cloth. 9. Substitution of components may impair hazardous location safety. 0. No revision to drawing without prior FM Approval. 9

10 Intrinsic Safety Hazardous Location Installation Diagram EGC or P models approved for Intrinsically Safe Installations: IS Class I,II and III; Division, Groups A,B,C,D,E,F,G EGC or P * *Note: Any Visual Indicator/Trigger Assembly option is approved HAZARDOUS (CLASSIFIED) S Cl I,II,III; Div, Groups A,B,C,D,E,F,G Intrinsic Safety Barriers (Associated Apparatus) NON-HAZARDOUS (SAFE AREA) Individual Sensor wiring Control Equipment Bottom Sensor Barrier Top Sensor Barrier 6 Shields 7 Intrinsically Safe Ground 8 EG Enclosure EG Pin Identifiers Pins EG Top Sensor + Bottom Sensor + Bottom Sensor - Top Sensor - INSTALLATION NOTES: EG Entity Parameters: Ui (Vmax) = Vdc; Ii (Imax) = 0 ma ; Ci = 98 nf; Li =.6 mh; Pi =.0 W Uo < Ui (Vmax); Io < Ii (Imax); Ca > Ci + Ccable, La > Li + Lcable.. Control equipment connected to barrier must not use or generate more than 0 Vrms or Vdc.. Installation should be in accordance with ANSI/ISA RPA.6.0 "Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations" and the National Electrical Code (ANSI/NFPA 70) or in accordance with the Canadian Electric Code.. Associated apparatus manufacturer's installation drawing must be followed when installing this equipment.. To maintain intrinsic safety, wiring associated with each sensor or solenoid coil wiring must be run in separate cables or separate shields connected to intrinsically safe (associated apparatus) ground. Each Sensor and Solenoid coil shall be wired as separate intrinsically safe circuits. 6. Shield Grounding - Upon installation verify electrical continuity between shield and ground terminal. 7. Resistance between Intrinsic Safe Ground and earth ground must be less than one ohm. WARNING: 8. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in location where it may be subjected to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should only be done with a damp cloth. 9. Substitution of components may impair hazardous location safety. 0

11 Intrinsic Safety (FISCO) Hazardous Location Installation Diagram FISCO Concept The FISCO Concept allows the interconnection of intrinsically safe apparatus to associated apparatus not specifically examined in such combination. The criterion for such interconnection is that voltage (Vmax), the current (Imax), and the power (Pi), which intrinsically safe apparatus can receive and remain intrinsically safe, considering faults, must be equal to or greater than the voltage (Uo, Voc, Vt), the current (Io, Isc, It), and the power (Po) which can be provided by the associated apparatus (supply unit). In addition, the maximum unprotected residual capacitance (Ci) and inductance (Li) of each apparatus (other than the terminators) connected to the Fieldbus must be less than or equal to nf and 0µH respectively. In each I.S. Fieldbus segment only one active source, normally the associated apparatus, is allowed to provide the necessary power for the Fieldbus system. The allowed voltage (Uo, Voc, Vt) of the associated apparatus used to supply the bus must be limited to the range of V d.c. to V d.c. All other equipment connected to the bus cable has to be passive, meaning that the apparatus is not allowed to provide energy to the system, except to a leakage current of 0µA for each connected device. Separately powered equipment needs a galvanic isolation to insure that the intrinsically safe Fieldbus circuit remains passive. The cable used to interconnect the devices must comply with the following parameters: Loop resistance R : - 0 ohm/km Inductance per unit length L : 0. - mh/km Capacitance per unit length C : 80-00nF/KM C = C line to line + ½ C line to shield, if both lines are floating with respect to shield or C = C line to line + C line to shield, if one line is connected to shield Trunk Length: < 000 meters Spur Length: < 0 meters Splice Length: < meters FM Approved line terminators must be used on each end of the trunk cable that have the following parameters: R = ohms C = µf (See Page for Installation Diagram and Notes)

12 Intrinsic Safety (FISCO) Hazardous Location Installation Diagram EG9C or P * models approved for Intrinsically Safe (FISCO) Installations: IS Class I,II and III; Division, Groups A,B,C,D,E,F,G *Note: All Entry options and Visual Indicator/Trigger Assembly options are approved HAZARDOUS (CLASSIFIED) IS (FISCO) Cl I,II,III Div, Groups A,B,C,D,E,F,G NON-HAZARDOUS (SAFE AREA) EG9 Enclosure FM/CSA Approved Control Equipment FM/CSA Approved Termination FM/CSA Approved Fieldbus Device n suitable for FISCO FM/CSA Approved Fieldbus Device suitable for FISCO FB + FB - Quick Connector Pin-out located below Pins EG9 FB - FB + N/C Pins EG9 FB - FB + N/C SIM JMPR SIM JMPR Solenoid - Solenoid + INSTALLATION NOTES: EG9 Entity Parameters (FISCO): Ui (Vmax)=0 Vdc; Ii (Imax)=80 ma; Ci 0.0 nf; Li=0.0 mh; Pi=. W. Installation shall be in accordance with ANSI/ISA RPA.6.0, ANSI/NFPA 70, and the National Electrical Code or in accordance with the Canadian Electric Code.. Control equipment must be FM or CSA Approved Associated Apparatus suitable for FISCO.. Control equipment connected to FISCO barrier must not use or generate more than 0Vrms or Vdc.. Resistance between FISCO Intrinsically Safe Ground and earth ground must be less than.0 Ohm. WARNING:. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in location where it may be subjected to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should only be done with a damp cloth. 6. Substitution of components may impair hazardous location safety. 7. Approval Agency controlled Installation Diagram. No revision to diagram allowed without prior Factory Mutual or Approval Agency authority.

13 Non-Incendive Field Wiring Apparatus Installation Drawing EG9C or P * models approved for Non-Incendive Field Wiring Apparatus: NI Class I,II and III; Division, Groups A,B,C,D,F,G *Note: All Entry options and Visual Indicator/Trigger Assembly options are approved HAZARDOUS (CLASSIFIED) Nonincendive Field Wiring Apparatus NI; Cl I,II,III Div Groups A,B,C,D,F,G NON-HAZARDOUS (SAFE AREA) EG9 Enclosure Power Limiting Associated Apparatus Control Equipment Solenoid Connector Bus Connector FB + FB - Quick Connector Pin-out located below Pins EG9 FB - FB + N/C Pins EG9 FB - FB + N/C SIM JMPR SIM JMPR Solenoid - Solenoid + INSTALLATION NOTES: Entity Parameters: EG9 : Ui = 0 Vdc; Ii = 80 ma ; Ci = 0.0 nf; Li = 0.0 mh; Pi =. W. Installation shall be in accordance with ANSI/ISA RPA.6.0, ANSI/NFPA 70, and the National Electrical Code.. Control equipment must be FM approved to supply power in Class I, Division Areas.. Power Limiting Associated Apparatus must satisfy the conditions: Voc or Vt < Ui, Isc or It < Ii, Ca > Ci + Ccable, La > Li + Lcable of the EG9 Entity Parameters. Manufacturer's associated non-incendive field wiring apparatus installation drawing must be followed when installing this equipment.. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in location where it may be subjected to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should only be done with a damp cloth. 6. Substitution of components may impair hazardous location safety.

14 Non-Incendive Field Wiring Apparatus Installation Drawing EG96C or P_* and EG97C or P_*models approved for Non-Incendive Field Wiring Apparatus: NI Class I,II and III; Division, Groups A,B,C,D,F,G *Note: All Entry options and Visual Indicator/Trigger Assembly options are approved HAZARDOUS (CLASSIFIED) Nonincendive Field Wiring Apparatus NI; Cl I,II,III Div Groups A,B,C,D,F,G NON-HAZARDOUS (SAFE AREA) EG96 or EG97 Enclosure Power Limiting Associated Apparatus Control Equipment Solenoid Connector Bus Connector ASI + ASI - Quick Connector Pin-out located below Pins EG96 and EG97 AS-I + AS-I - Pins EG96 and EG97 AS-I + AS-I - N/C Solenoid - Solenoid + INSTALLATION NOTES: Entity Parameters: EG96 or EG97 : Ui = 7 Vdc; Ii = 0 ma ; Ci = 0.0 nf; Li = 0.0 mh; Pi =.0 W. Installation shall be in accordance with ANSI/ISA RPA.6.0, ANSI/NFPA 70, and the National Electrical Code.. Control equipment must be FM approved to supply power in Class I, Division Areas.. Power Limiting Associated Apparatus must satisfy the conditions: Voc or Vt < Ui, Isc or It < Ii, Ca > Ci + Ccable, La > Li + Lcable of the EG96 or EG97 Entity Parameters. Manufacturer's associated non-incendive field wiring apparatus installation drawing must be followed when installing this equipment.. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in location where it may be subjected to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should only be done with a damp cloth. 6. Substitution of components may impair hazardous location safety.

15 INSTALLATION ADDENDUM EN and EG series SPECIFIC CONDITIONS OF USE / MARKING For EN and EG Series FM08ATEX00X Specific Conditions of Use - Notes. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions which might cause a build up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should be done only with a damp cloth. For EN and EG Series FM7US09X Specific Conditions of Use - Notes. Part of the enclosure is constructed from plastic. To prevent the risk of electrostatic sparking the plastic surface should only be cleaned with a damp cloth. Marking ATEX II G Ex ia IIC T Ga Ta = -0 C to +80 C Marking *NI / I / / ABCD - 09 *S / II / / FG *IS / I, II, III / / ADBCDEFG - 09 *See Approval Certificates for applicable models / type codes. Materials - Enclosure: Polycarbonate - Seal: Buna-N or RTV0 Attention: Replace only with identical factory parts/components. Deviation from the installation conditions in the Installation Manual and this addendum may invalidate this product's conformity with the Explosive Atmospheres, Pressure Equipment, and EMC Directives. Conformity of this product with any other "CE Mark" Directive(s) shall not be assumed. Contact StoneL for help with replacements or emergency maintenance. For installation manuals in a community language other than English, please contact StoneL. DECLARATION OF CONFORMITY Manufacturer: StoneL 67 US Highway 9 Fergus Falls, Minnesota 67 USA Products: Eclipse EN Series Valve Position Monitors and Valve Communication Terminals Eclipse EG Series Valve Position Monitors and Valve Communication Terminals Model - Type Certificates / Directives / Standards Marking EN and EG Series EN and EG Series EU Type Examination Certificate FM08ATEX00X ATEX 0//EU EN :0+A:0, EN :0 EMC 0/0/EU EN :007/A:0 EMC 0/0/EU EN :007/A:0 ATEX II G Ex ia IIC T Ga ATEX Notified Bodies for EU Type Examination Certificates: FM Approvals Ltd. Windsor, Berkshire, UK (Notified Body Number 7) Quality Assurance Certificates: ISO 900:008...TUV SUD America Inc. QAN FM06ATEXQ00.FM Approvals (Notified Body Number 7) QAR GB/FME/QAR.000..FM Approvals (Notified Body Number 7) We declare under our sole responsibility that the products, as described, are in conformity with the listed standards and directives. Fergus Falls, st August 07 Bryan Beckman, Quality Manager Authorized Person of the Manufacturer 0revE

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) Publication# 03revA Table of Contents Publication# 03revA Table Of Contents...

More information

Installation Manual OPEN. For Corrosive Service. The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure.

Installation Manual OPEN. For Corrosive Service. The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure. For Corrosive Service Installation Manual The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure. OPEN StoneL Corporation One StoneL Dr 26275 US Hwy 59 Fergus Falls,

More information

LIMIT SWITCH Axiom - AX

LIMIT SWITCH Axiom - AX LIMIT SWITCH Axiom - AX with FOUNDATION Fieldbus Installation, Maintenance and Operating Instructions (AX93 ) 2 Table of Contents Table Of Contents... Page 2 Axiom Model Guide... Page 3 Dimensions and

More information

LIMIT SWITCH Axiom - AX

LIMIT SWITCH Axiom - AX LIMIT SWITCH Axiom - AX with AS-Interface (Standard Addressing) Installation, Maintenance and Operating Instructions (AX9 ) 2 Table of Contents Table Of Contents... Page 2 Axiom Model Guide... Page 3 Dimensions

More information

LIMIT SWITCH Prism - PI

LIMIT SWITCH Prism - PI LIMIT SWITCH Prism - PI with SST Switching Sensors Installation, Maintenance and Operating Instructions (PI ) Publication# 07revA Table of Contents Publication# 07revA Table Of Contents... Page Prism PI

More information

LIMIT SWITCH Axiom - AX

LIMIT SWITCH Axiom - AX LIMIT SWITCH Axiom - AX with SST Switching Sensors Installation, Maintenance and Operating Instructions (AX33 ) Publication# 10532revB 2 Table of Contents Publication# 10532revB Table Of Contents... Page

More information

JM - Junction Enclosure Modules for Communication Networks

JM - Junction Enclosure Modules for Communication Networks Pub #110014revB, Part 1-12/2002 JM - Junction Enclosure Modules for Communication Networks Installation & Adjusting Instructions for JMT, JMP, JMS, JMD, JMB series The JM provides a watertight / explosion

More information

WARNING! READ BEFORE INSTALLATION

WARNING! READ BEFORE INSTALLATION A4 INTRINSICALLY SAFE & NON-INCENDIVE RATED PRESSURE TRANSMITTER INSTRUCTION SHEET WARNING! READ BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure,

More information

m WARNING! READ m BEFORE INSTALLATION

m WARNING! READ m BEFORE INSTALLATION m WARNING! READ m BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure, excessive vibration or pressure pulsation, excessive instrument temperature,

More information

Quartz. Save Space with Low Profile Design

Quartz. Save Space with Low Profile Design Quartz The Quartz is available in explosion proof (QX), nonincendive and intrinsically safe (QN) and general purpose (QG) versions. The robust epoxy coated anodized aluminum construction makes this platform

More information

Eclipse Compact and modular with solid state reliability

Eclipse Compact and modular with solid state reliability Eclipse ompact and modular with solid state reliability StoneL s Eclipse features dual solid state sensors with optional communications neatly integrated into a sealed module. The function module and trigger/indicator

More information

Prism PI Intelligent features offer advanced performance

Prism PI Intelligent features offer advanced performance Prism PI Intelligent features offer advanced performance The Prism PI integrates an advanced position sensing system and integral pneumatic control for sanitary diaphragm and other linear applications.

More information

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1 Ex Instruction manual Rotamass Coriolis mass flow meter IM 01U10X03-00EN-R, 1st edition, 2017-02-08 Rev -1 Table of contents Table of contents 1 Introduction... 3 1.1 Scope of application... 3 1.2 Applicable

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below

More information

Quartz Explosionproof valve monitoring

Quartz Explosionproof valve monitoring Quartz Quartz Explosionproof valve monitoring The Quartz is available The Quartz series in explosionproof (QX), The StoneL Quartz series is durable, corrosion resistant, and versatile, nonincendive, intrinsically

More information

ADVANCED AUTOMATION SYSTEM. Installation, Maintenance and Operating Instructions

ADVANCED AUTOMATION SYSTEM. Installation, Maintenance and Operating Instructions ADVANCED AUTOMATION SYSTEM Installation, Maintenance and Operating Instructions IMO-550EN 2/2016 2 IMO-550EN Table of Contents 1 GENERAL........................................ 3 1.1 Warning......................................

More information

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer CONTROL SYSTEMS 1239 WILLOW LAKE BOULEVARD VADNAIS HEIGHTS, MINNESOTA 55110 651 766 2700 Fax: 651 766 2701 www.control systems.usfilter.com Product Specification A1000i Loop Powered/4-20mA Submersible

More information

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof

More information

Prism PI Intelligent features offer advanced performance

Prism PI Intelligent features offer advanced performance Prism PI Intelligent features offer advanced performance The Prism series integrates an advanced position sensing system and integral pneumatic control for sanitary diaphragm and other linear applications.

More information

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions FAIRCHILD T800 SERIES STANDARD RANGE MINIATURE TWO-WIRE, PI PRESSURE TRANSDUCER Installation, Operation and Maintenance Instructions Model TT800 Model TA800 Model TD800 Inlet Port (Channel 2) Inlet Port

More information

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer CONTROL SYSTEMS 1239 WILLOW LAKE BOULEVARD VADNAIS HEIGHTS, MINNESOTA 55110 651 766 2700 Fax: 651 766 2701 www.control systems.usfilter.com Product Specification A1000i Loop Powered/4-20mA Submersible

More information

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors

More information

Model 8800C Vortex Flowmeter

Model 8800C Vortex Flowmeter Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Review Flowmeter Configuration Product Certifications

More information

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NT / 3/ / 5/ 5/3 Features Available in different coil terminations H Class coil construction Designed

More information

Axiom AX by StoneL. Installation, Maintenance and Operating instructions. StoneL publication revA

Axiom AX by StoneL. Installation, Maintenance and Operating instructions. StoneL publication revA Axiom AX by StoneL Installation, Maintenance and Operating instructions 7 AX 70 en 03/2017 2 Axiom AX 7 AX 70 en Table of contents 1 General 3 1.1 Introduction 3 1.2 Title plate markings 3 1.3 CE markings

More information

Axiom AMI by StoneL. Installation, Maintenance and Operating instructions. StoneL publication revA

Axiom AMI by StoneL. Installation, Maintenance and Operating instructions. StoneL publication revA Axiom AMI by StoneL Installation, Maintenance and Operating instructions 7 AMI 70 en 0/07 Axiom AMI 7 AMI 70 en Table of contents General. Introduction. Title plate markings. CE markings. Recycling and

More information

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09 Logix 510si Series Digital Positioner TECHNICAL BULLETIN FCD LGENTB0510-01 09/09 Experience In Motion Introduction The Logix 510si series are single acting, user-friendly digital positioners. As all positioners

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1345550 Issued to: Eaton Electric Ltd. Great Marlings Butterfield, Luton Bedfordshire LU2 8DL United Kingdom Attention: Mr. Peter Rigling The products listed

More information

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION page 1 DESCRIPTION The switch boxes are suitable for rotary actuators and are the industry leader in versatility, quality and approvals gained. Models include APS standard range with a variety of outputs

More information

ValvePoint: valve communication and control

ValvePoint: valve communication and control ValvePoint: valve communication and control table of contents Reference guide Application guidelines for platforms and switches/vcts Pages 4-5 Quartz Versatile explosionproof monitoring platform Pages

More information

707Ex. Users Manual. ma Calibrator

707Ex. Users Manual. ma Calibrator 707Ex ma Calibrator Users Manual March 2003 Rev 2 3/03(English) 2003 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2 Fieldbus Segment Protector Features Assembly 4... 10 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur Segment Protector in Zone 2/Div. 2 Instruments in Zone

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance (033332_0_000) Issued to: Rosemount Inc. 6021 Innovation Blvd. Shakopee, Minnesota 55379-9795 USA Attention: Glen Edwards The products listed below are eligible to bear the CSA

More information

Fisher i2p 100 Electro Pneumatic Transducer

Fisher i2p 100 Electro Pneumatic Transducer Product Bulletin D103197X012 i2p 100 Transducer Fisher i2p 100 Electro Pneumatic Transducer The Fisher i2p 100 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a milliampere

More information

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance  Output Range Type 500X Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions Ordering Information Type 500X I/P Transducers Output Range Part Number Input psi bar Impedance Pilot

More information

valve communication and control

valve communication and control valve communication and control Connecting the process. StoneL. Our focus is to enable process users to cut costs and improve operating performance by adopting proven, field based communication technologies.

More information

V200 Series Positioners

V200 Series Positioners V200 Series Positioners In a single compact and rugged housing The V200 positioner incorporates the flexibility of converting from a pneumatic unit to several versions of an electropneumatic unit, and

More information

valve communication and control

valve communication and control StoneL: valve communication and control Now Featuring Wireless Link Quick reference All product names used herein are trademarks of their respective owners. Quick reference Application guidelines for

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 - Type 2000 Pneumatic and Electropneumatic Valve Positioner Installation, Operation and Maintenance Instructions Ordering Information Use this coding system to order Model CA20 - Type of Positioner 00 P/P

More information

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc. All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed as warranties

More information

Assembly. Trunk IN + - S U, I U, I. Spur 1

Assembly. Trunk IN + - S U, I U, I. Spur 1 FieldBarrier FD0-FB-Ex.* Features Assembly outputs Ex ia IIC FieldBarrier in Zone /Div. Instruments in Zone 0.../Div. Short circuit current limitation per output For FOUNDATION Fieldbus H and PROFIBUS

More information

Electrical: Valve monitoring and control circuits

Electrical: Valve monitoring and control circuits Electrical: Valve monitoring and control circuits Valve monitoring and communication Electrical: valve monitoring and control circuits Overview This section covers valve monitoring circuits for interfacing

More information

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional

More information

Features. Flexibility

Features. Flexibility The V100 positioner can be ordered as a base model pneumatic positioner, converted to standard NEMA 4X electropneumatic, EX model, or FF (fail freeze) model in a matter of minutes, without removing the

More information

AXIOM AN SERIES VALVE COMMUNICATION AND CONTROL NONINCENDIVE & I.S. ON/OFF VALVE CONTROLLER. on-off controller AXIOM AN

AXIOM AN SERIES VALVE COMMUNICATION AND CONTROL NONINCENDIVE & I.S. ON/OFF VALVE CONTROLLER. on-off controller AXIOM AN AXIOM AN SERIES VALVE COMMUNICATION AND CONTROL NONINCENDIVE & I.S. ON/OFF VALVE CONTROLLER on-off controller AXIOM AN 7 AN 20 EN 2/2018 METSO 7 AN 20 EN Axiom AN Advanced performance The Axiom AN series

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Fisher 3660 and 3661 Positioners

Fisher 3660 and 3661 Positioners 3660 and 3661 Positioners Product Bulletin Fisher 3660 and 3661 Positioners Fisher 3660 pneumatic and 3661 electro pneumatic single acting positioners are used with various actuators on sliding stem valves

More information

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control Miniature I/P, E/P Transducer for Electronic Air Pressure Control Self-correcting to maintain precise control The Type-900X I/P, E/P transducer converts an electrical signal (current or voltage) to a proportional

More information

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control Type 900X Miniature I/P, E/P Transducer for Electronic Air Pressure Control Self-correcting to maintain precise control Available with zero-based ranges The Type-900X I/P, E/P transducer converts an electrical

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1132623 (LR 82598) Master Contract: 160686 Project: 2567317 Date Issued: November 5, 2012 Issued to: Endress + Hauser Flowtec AG Kagenstrasse 7 Reinach, Basel Land

More information

Quartz Explosionproof valve monitoring

Quartz Explosionproof valve monitoring Quartz Explosionproof valve monitoring The Quartz is available in explosionproof (QX), nonincendive, intrinsically safe (QN), and general purpose (QG) versions. The robust epoxy-coated anodized aluminum

More information

Quartz Explosionproof valve monitoring

Quartz Explosionproof valve monitoring Quartz Explosionproof valve monitoring The Quartz is available in explosionproof (QX), nonincendive, intrinsically safe (QN), and general purpose (QG) versions. The robust epoxy-coated anodized aluminum

More information

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating V200 Positioner Housing Material: Cast aluminium with polyester coating Indicator Options: Flat pointed indicator or raised indicator (red/green or yellow/black) One housing for pneumatic or electropneumatic

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Instruction Manual 646 Transducer Fisher 646 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 3 Specifications... 4 Educational Services... 4 Installation...

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Instruction Manual 646 Transducer Fisher 646 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 3 Specifications... 4 Educational Services... 4 Installation...

More information

Axiom Explosionproof Advanced performance and reliability in harsh environments

Axiom Explosionproof Advanced performance and reliability in harsh environments Axiom Explosionproof Advanced performance and reliability in harsh environments The Axiom explosionproof platform, available in epoxycoated anodized aluminum or stainless steel, will withstand your most

More information

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc. CONTROLS A Division of BRAY INTERNATIONAL, Inc. Bray Pneumatic Actuators & Accessories Technical Manual TM-056 Pneumatic Actuator - 08//00 Bray Pneumatic Actuators & Accessories Technical Manual - Table

More information

General purpose / hazardous area

General purpose / hazardous area Providing integrated monitoring and control of automated process valves the Z series is designed for both general purpose and hazardous area applications Features General application The Z-series rotary

More information

LIMIT SWITCH Prism - PI

LIMIT SWITCH Prism - PI LIMIT SWITCH Prism - PI with DeviceNet Installation, Maintenance and Operating Instructions (PI9 ) Publication# 05373revA Table of Contents Publication# 05373revA Table Of Contents... Page Prism PI Model

More information

Low Flow Transmitter EJX115A and EJA115E

Low Flow Transmitter EJX115A and EJA115E User s Manual Low Flow Transmitter EJX115A and EJA115E 9th Edition i Low Flow Transmitter EJX115A and EJA115E 9th Edition Contents 1. Introduction... 1-1 Regarding This Manual...1-1 Trademarks...1-2 1.1

More information

ACCUTRAK ROTARY MODELS 1040/9358/2004/9044/9468/5004/5044/2007/9479/5050 INSTALLATION AND OPERATIONS MANUAL

ACCUTRAK ROTARY MODELS 1040/9358/2004/9044/9468/5004/5044/2007/9479/5050 INSTALLATION AND OPERATIONS MANUAL Installation and operating instructions for AccuTrak position monitor rotary models 1 INTRODUCTION 1.1 Product Certification 1040/9358: CSA Type 4 (Cert. #1185829) 2004: CSA Type 4 (Cert. #2599677) 9044:

More information

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09 Logix 520MD Series Digital Positioner TECHNICAL BULLETIN FCD LGENTB0520-01 11/09 Experience In Motion Introduction The Logix 520MD Series combines superior positioning and tuning functions with convenient

More information

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions FAIRCHILD T500 SERIES ELECTRO-PNEUMATIC TRADUCER Installation, Operation and Maintenance Instructions Identification Number Underwriting Group Factory Mutual Canadian Standard T (F) (C) 500- Approval Class

More information

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter Product Bulletin D200437X012 3710 and 3720 Positioners Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter Fisher 3710 pneumatic (figure 1) and 3720 electro pneumatic positioners (figure

More information

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13 Logix 510si Series Digital Positioner TECHNICAL BULLETIN FCD LGENTB0510-02 09/13 Experience In Motion Introduction The Logix 510si series are single acting, user-friendly digital positioners. As all positioners

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T5220 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved 0745A Load Cell Global Usage Fully Approved for Accuracy and Safety Floor Scales Use the 0745A load cell in platform and floor scales. Due to the hermetic welded design the 0745A is ideal for harsh environments

More information

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories Selection and Application Associated s T 8355 EN ff. Edition January 2010 Information Sheet T 8350 EN Positioners,

More information

Magnetic Level Gauges

Magnetic Level Gauges Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Fluid Control

More information

D Series Ex d Stainless Steel

D Series Ex d Stainless Steel 2 Way irect Acting Solenoid Valve IIC T4/T6 Series Stainless Steel 2 and 3 Way irect Acting Solenoid Valve IIC T4/T6 2SK-CM [ FEATURES ] Integral terminal box with coil housing. Valve do not require minimum

More information

Valve model number description

Valve model number description 0-30.3-6 Valve model number description Every MAXON Series 8000 Valve can be accurately identified by the model number shown on the valve nameplate. The example below shows a typical Series 8000 Valve

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc.

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc. AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RPM Series Float Level Sensors Rev. E, 08/16 Doc. 9002103 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com

More information

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics Backplane bus for the IS1 system, constisting of data bus, PowerBus and address circuits For 2 or 4 modules Installation on 35 mm DIN rails NS 35/15 The BusRail can be interconnected for up to 18 modules

More information

ADVANCED AUTOMATION SYSTEM

ADVANCED AUTOMATION SYSTEM ADVANCED AUTOMATION SYSTEM The CINTAC Advanced Automation System combines JAMESBURY actuator expertise with STONEL advanced communication and control system technology to form a totally compact, integrated

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13 Logix 505si Series Digital Positioner TECHNICAL BULLETIN FCD LGENTB0505-03 09/13 Experience In Motion Introduction The Logix 505si is a basic positioner for most simple control loops. It is microprocessor

More information

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information. Type 500X Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions Ordering Information Type 500X I/P Transducers Output Range Part Number Input psi kpa Impedance 500-AA

More information

Electropneumatic Transducer (I/P, E/P)

Electropneumatic Transducer (I/P, E/P) Type 500X Electropneumatic Transducer (I/P, E/P) Economical and reliable electrical conversion to pressure The ControlAir Type 500X converts a current or voltage input signal to a linearly proportional

More information

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008 Data Sheet GT1000 Series Brooks GT1000 Series Industrial Glass Tube Variable Area Flowmeters Model GT1020 Model GT1024 DESIGN FEATURES Brass or 316L SS (1.4404) end fittings Flanged or threaded connections

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1345550 (LR 36637) Master Contract: 152423 Issued to: Measurement Technology Limited Great Marlings Butterfield Luton, Bedfordshire LU2 8DL United Kingdom Attention:

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

AXIOM AX SERIES VALVE COMMUNICATION AND CONTROL EXPLOSIONPROOF ON/OFF VALVE CONTROLLER. on-off controller AXIOM AX

AXIOM AX SERIES VALVE COMMUNICATION AND CONTROL EXPLOSIONPROOF ON/OFF VALVE CONTROLLER. on-off controller AXIOM AX AXIOM AX SERIES VALVE COMMUNICATION AND CONTROL EXPLOSIONPROOF ON/OFF VALVE CONTROLLER on-off controller AXIOM AX 7 AX 1 EN /018 METSO 7 AX 1 EN Axiom AX Advanced performance and reliability in harsh environments

More information

Rosemount 3051CFA Annubar Flowmeter

Rosemount 3051CFA Annubar Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Type 4746 Electric or Pneumatic Limit Switch

Type 4746 Electric or Pneumatic Limit Switch Type 4746 Electric or Pneumatic Limit Switch Application Limit switches with inductive, electric or pneumatic contacts for attachment to pneumatic or electric control valves, to Type 4763 Electropneumatic

More information

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type 1001 Transducers. I/P & E/P Transducers Type 1001 I/P & E/P Description The Type 1001 is a patented family of electropneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional

More information

Safety Instructions Proline Promass 300

Safety Instructions Proline Promass 300 XA01472D/06/EN/01.16 71327890 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 1, AEx/Ex de ia IIC/IIB Class I, Zone 1, AEx/Ex d ia IIC/IIB Zone 21, AEx/Ex tb IIIC Txx

More information

LIMIT SWITCHES & POSITION INDICATION

LIMIT SWITCHES & POSITION INDICATION LIMIT SWITCHES & POSITION INDICATION Engineering Creative Solutions for Fluid Systems Since 1901 TECHNOPOLYMER LIMIT SWITCH DESCRIPTION The Pratt Industrial MS41-2 Limit Switch Box represents a new dimension

More information

Fisher FIELDVUE DVC6000 Digital Valve Controllers

Fisher FIELDVUE DVC6000 Digital Valve Controllers Quick Start Guide DVC6000 Digital Valve Controller Fisher FIELDVUE DVC6000 Digital Valve Controllers Contents Using this Guide... 8 Installation... 10 Basic Setup and Calibration... 32 Specifications...

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:

More information

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR LOR STER INDUSTRIL UTOMTION Intrinsically safe barrier with separation FIELDUS TRNSMISSION LINES CONVERTER-SEPRTOR type SEx-RS RS/RS, RS/, /RS, /, RS/RS - group I, category M and group II and III, category

More information

RAE PowerPak User s Guide

RAE PowerPak User s Guide RAE PowerPak User s Guide \\\\\ Rev. A July 2009 P/N F03-4001-000 Copyright 2009 RAE Systems, Inc. Ordering Replacement Parts: If you need replacement parts, a list is available online: http://www.raesystems.com

More information