L21 Magnetic Level Indicator Float magnetic level meter for continuous level measurement of liquids

Size: px
Start display at page:

Download "L21 Magnetic Level Indicator Float magnetic level meter for continuous level measurement of liquids"

Transcription

1 L21 Magnetic Level Indicator Float magnetic level meter for continuous level measurement of liquids Remote data transmission Use in potentially explosive atmospheres Robust and versatile design Reasonable price Doc. no.: 151, en_cat_l21_emkometer, 1/2016

2 Content Measurement and Regulation L21 Magnetic Level Indicator... 1 Description... 4 Principle of operation... 5 A Basic configuration... 7 A1 L21 for applications up to PN A2 L21 for applications up to PN A3 L21 for applications up to PN A4 L21 for applications up to PN A5 L21 for applications up to PN A6 L21 with double connection A7 L21 with polymeric coating (ETFE, PE, PFA, PTFE) A8 L21 combined chamber for easier transport and installation A9 L21 plastic version (PVDF / PP / PVC) up to PN A10 L21 with bypass chamber for measurement and sampling A11 L21 with chamber for independent transmitters and other level sensors A12 L21 with extended chamber for independent transmitters and other level sensors A13 L21 with extended chamber for dirty fluid, sticky products or liquefied gases A14 L21 chamber for level switch located above A15 L21 conductivity probes for level indication / float switches A16 L21/C magnetic level indicator for containers A17 L21 with optional mounting attachment A18 L21 with an additional chamber for the compensator weight float A19 L21/4 top mounted level indicator Example of use of level indicator connection options A19 L21/4 top mounted level indicator A20 L21/4 top mounted level indicator for low density / high pressure A21 L21/3 with a float on a string A22 L21/5 buoyancy level indicator B Advanced configuration B1 Float for bypass level indicator L Float dimensions and dependence on the density B2 Standard options for top of chamber B3 Standard options for bottom of chamber B4 Orientation of process connection of 61

3 B5 Process connection type B6 Magnetic roller indicator B7 Stainless steel scale B8 Connecting option C Accessories C1 SPJ Limit switch C2 Potentiometric level sensor SP C3 Potentiometric level sensor SP4 in Ex d execution C4 Magnetostrictive level sensor SP4/M C5 EMKOTDR 60 Radar level meters with guided wave C6 EMKOCAP 25 Capacitive level meters EMKOCAP 26 Capacitive level meters C7 Thermal insulation C8 Electrical heating with thermal insulation OE C9 Heating jacket (steam, water) with insulation C10 Signal transducers of level or L21 Manufacturer type number Ordering Appendix Appendix Appendix Appendix Appendix Appendix of 61

4 Description The sensor type L21 is used to measure l emkotdr evels or interface of fluids in both open and pressurized tanks. It can also be used in applications with the formation of foam or aerosol, where contactless measurement methods fail. Body material of these level gauges is high quality stainless steel or chemically resistant materials. Local measurement is independent from external electrical supply which allows measurement of flammable, chemically corrosive and toxic substances also in very difficult conditions, such as high process s and pressures. On the customer's request indicator can be equipped with limit switches that allow remote monitoring of minimum or maximum level of liquid in the tank, control of pumps, opening or closing valves, etc. It can also be equipped with a continuous sensor with 4 20 ma current output for exact monitoring of the level in the tank remotely. Several optional digital communication protocols are available such as HART, Foundation FIELDBUS, PROFIBUS etc. There are several options of transmitters including reed chain, magnetostrictive, capacitive and radar principles. Mechanical local indication can be extended by a range of displays. All the devices are available for potentially explosive atmospheres with ATEX certificates. For easy draining (venting) there is screwed plug optionally accompanied by a valve. Local indicator is available in the following two options: Glass tube in which a level indicator moves tracking magnet Rolling magnetic rollers in the bar, changing color according to the level (white red). For extreme conditions it can be equipped with insulated tube, steam or electric heating of the measuring tube. Several insulation options are available according to the process conditions. L21 is a very complex product and there are many choices that are not published here. Please contact your local distributor or factory in case of any specific requests or questions. Product features Simple, robust and proven stainless steel design Ability to make parts in contact with the medium of PP, PVDF, PVC, Hastelloy or other materials in case of corrosive substances Stable local indication without need of power supply Pressure resistant and gas tight separation of the medium and indicators Easy installation of the accessories using the mounting rails (limit contacts, display outputs, scales) Indicators including limit switches and continuous outputs can be replaced without draining the tank Insulated, steam or electric heated options available. Interface measurement is possible as well In comparison with direct gauges it has lower risk of leaks and clearer local indication The device is approved for use in potentially explosive atmospheres of pressure vessels and boilers Device is designed and pressure tested according to the customers needs including s from 196 C up to 525 C Device is manufactured with accordance to PED 97/23/ES and corresponding standards Each device is pressure tested and verified. Calibration and strict functional tests are also performed on every device at the factory 4 of 61

5 Principle of operation The sensor is connected via flanges or threaded connections in a vertical position to the side of the tank, in which level or interface of the liquid should be monitored. It works on the principle of connected vessels. There is sealed bypass chamber with a float inside. Float has a built in permanent magnet and follows the level of liquid in the observed tank. Local indicator as well as additional sensors are magnetically coupled to the float. As the float changes its position, magnetic rollers follow it changing their orientation and thus the color (from white to red) indication current level directly. Similarly, shuttle follower indicates the level. If requested, device can be equipped with stainless steel scale in chosen units of length, volume, percentage etc. Local indication Float Medium Float is specifically designed, manufactured and tested for requested conditions of use. Double pole magnetic system is used to create uniform and strong 360 magnetic field. Magnetic system has a high gauss rating providing large safety zone for long term service taking in count effects of ageing of the magnets over time. Basic analogue output is based on the reed chain. Reed switches together with a network of resistors form three wire potentiometric circuit. The resistance between one pole and the wiper (here represented by the magnet in the float) is proportional to the level in the tank. Resistance is converted using the transducer to the standard analog signal 4 (0) to 20 ma for further processing, or advanced transducers can be used for digital communication such as HART, FOUNDATION FIELDBUS, PROFIBUS, Modbus, RS 485 and others. More advanced methods of position sensing include capacitive, guided radar and magnetostrictive principles. Detailed information is available upon request in separated datasheets. Similarly, it is possible to use a magnetic switch as a limit sensor to indicate the minimum, maximum or other selected position level in the tank. Permanent magnet in the float in this case activates the reed contact (or moves a cam that activates a micro switch in SPM version). Based on the rating of the switch it can be used directly to perform some desired function or the signal can be amplified or processed in the control system. This solution is fully comparable with the semiconductor sensing elements in the terms of reliability and precision. SIL 2 certificate is available for selected configurations. Reliability indicators are available upon request. 5 of 61

6 Plug G1/2 Measurement and Regulation Upper flange enables easy maintenance even in difficult condition, e.g. limited space under lower process connection Limit switch type SPJ Shut off valve either welded or flanged (on picture) allows maintenance without need to empty tank Scale, durable laser marked high quality stainless steel Process connection (flange, thread, pipe for welding, special) standardized or custom Level indication rail is always made from durable glass and aluminium with several types of rollers Float chamber manufactured according to the strict standards and codes including EN 13445, 12952, PED 97/23, ASME, NACE etc. Level sensor type SP4 for continuous level measurement (4 20 ma, HART, Foundation Fieldbus, Modbus, resistance) Ground clamp for ex application Indication plate allowing custom marking (TAG) User friendly flanges with hex screws for best weight / performance ratio and easy maintenance Drain plug / valve 6 of 61

7 A Basic configuration 7 of 61

8 A1 L21 for applications up to PN63 Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 63 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel 60,3 х 2,6 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 8 of 61

9 A2 L21 for applications up to PN100 Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 100 bar g Density of the medium 500 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel 63,5 х 3,5 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type list C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 9 of 61

10 A3 L21 for applications up to PN160 Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 160 bar g Density of the medium 500 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel 73,03 х 5,16 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 10 of 61

11 A4 L21 for applications up to PN250 Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 250 bar g Density of the medium 500 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel 71 х 7,5 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 11 of 61

12 A5 L21 for applications up to PN400 Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 500 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel 76 х 10 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 12 of 61

13 A6 L21 with double connection Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 13 of 61

14 A7 L21 with polymeric coating (ETFE, PE, PFA, PTFE) Standard specifications Medium Ambient Nominal pressure From 100 C to +250 C From 60 C to +85 C From 1 to 16 bar g Density of the medium 590 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Stainless steel Lining ETFE, PE, PFA, PTFE 70 х 2 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max Limit switch For details see type list C1 SP ma, HART, FIELDBUS, Electrical output PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI Insulation / heating For details see type lists C7, C8, C9 Other specifications on request We recommend ETFE. The most advanced method of lining 14 of 61

15 A8 L21 combined chamber for easier transport and installation Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 15 of 61

16 A9 L21 plastic version (PVDF / PP / PVC) up to PN16 Standard specifications Medium Ambient Nominal pressure PVDF from 10 C to +110 C PP from 10 C to +80 C PVC from 10 C to +80 C From 60 C to +85 C From 1 to 16 bar g Density of the medium 640 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request PVDF, PP, PVC 63 х 3,5 mm Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 16 of 61

17 A10 L21 with bypass chamber for measurement and sampling Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 640 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel Based on request Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 17 of 61

18 A11 L21 with chamber for independent transmitters and other level sensors Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Transmitter / level sensor Other specifications on request Stainless steel, Hastelloy, Monel Based on request Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 Capacitive EMKOCAP 25, 26 Guided radar wave EMKOTDR 60 For details see type lists C5, C6 18 of 61

19 A12 L21 with extended chamber for independent transmitters and other level sensors Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Transmitter / level sensor Other specifications on request Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 Capacitive EMKOCAP 25, 26 Guided radar wave EMKOTDR 60 For details see type lists C5, C6 19 of 61

20 A13 L21 with extended chamber for dirty fluid, sticky products or liquefied gases Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel 88,9 x 2,6; 100 x 10 Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 20 of 61

21 A14 L21 chamber for level switch located above Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 365 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M, L21/5 For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 21 of 61

22 A15 L21 conductivity probes for level indication / float switches Standard specifications Medium Ambient Nominal pressure Density of the medium External material of the bypass chamber and flanges Diameter of the external chamber Measurement range From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g 320 kg/сm kg/сm 3 Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 22 of 61

23 A16 L21/C magnetic level indicator for containers Standard specifications Medium Liquids and liquefied gases Density 400 kg/сm 3 Measurement range (one segment) Stainless steel/plastic Standard 0.3 to 6.0 m On request 0.3 to 9.0 m Accuracy ± 5 mm Repeatability ± 5 mm The maximum level 1 m/s change rate Maximum pressure standard stainless steel 4 MPa, on request 40 MPa Fluid Standard stainless steel 30 to +200 C Optional stainless steel 196 to +525 C Flanges: EN DN 15 to DN 50, PN 6 to PN 400, ASME B16.5, DIN, ГОСТ Process connection Thread: ½ " ¾" NPT, G ½ " ¾" Smooth pipe for welding (others on request) Material (parts in contact with fluid) Mounting position Local display DIN stainless steel (DIN , , ), Hastelloy, PVC, PP, PVDF, other on request Vertical (side, bottom, top) Roller indicator without scale Roller indicator with scale in selected units (m, m 3, %...) Glass tube with a magnet without scale Glass tube with a magnet with scale in selected units (m, m 3, %...) Scale Limit switch Electrical output mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 Other specifications on request 23 of 61

24 A17 L21 with optional mounting attachment Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 400 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 24 of 61

25 A18 L21 with an additional chamber for the compensator weight float Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 400 bar g Density of the medium 350 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Stainless steel, Hastelloy, Monel According to pressure and Up to 9000 mm Process connection Top of chamber, vent Bottom of chamber, drain Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Flat, semi circular bottom, flange, plug, valve, fittings For details see type list B3 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 25 of 61

26 A19 L21/4 top mounted level indicator L21/4 L21 L21/3 L21/4 Example of use of level indicator connection options Some conditions make difficult to use the float inside of the chamber. These conditions are for example too viscous substances, low density or intense formation of deposits. In these cases it is possible to use the version with a float outside of the chamber, connected to the gauge either by the string or by the rod. These variants are marked: L21/3 with a float on a string L21/4 with a float on a rod 26 of 61

27 A19 L21/4 top mounted level indicator Standard specifications Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to 40 bar g Density of the medium 350 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Stainless steel, Hastelloy, Monel, PP, PVDF According to pressure and From 3000 to 6000 mm Process connection Top of chamber, vent Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 27 of 61

28 A20 L21/4 top mounted level indicator for low density / high pressure Standard specification Medium Ambient Nominal pressure From 196 C to +500 C From 60 C to +85 C From 1 to bar g Density of the medium 300 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Stainless steel, Hastelloy, Monel 60,3 x 2,6 mm; 63,5 x 3,5 mm From 4000 to 6000 mm Process connection Top of chamber, vent Magnetic roller indicator Scale Limit switch Electrical output Insulation / heating Other specifications on request Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6 mm, cm, %, optional For details see type list B7 SPJ NAMUR, SPDT, min, max For details see type list C1 SP ma, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4 OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9 28 of 61

29 A21 L21/3 with a float on a string Standard specification Medium Ambient Nominal pressure From 60 C to +450 C From 60 C to +85 C From 1 to 300 bar g Density of the medium 600 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Stainless steel, Hastelloy, Monel According to pressure and From 100 to mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Magnetic roller indicator Local indication by pointer Scale Limit switch Electrical output Insulation / heating mm, cm, %, optional SPJ NAMUR, SPDT, min, max SP ma, HART, FIELDBUS, PROFIBUS, SP4/M OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI Other specifications on request 29 of 61

30 A22 L21/5 buoyancy level indicator Standard specification Medium Ambient Nominal pressure From 60 C to +450 C From 60 C to +85 C From 1 to 300 bar g Density of the medium 600 kg/сm 3 External material of the bypass chamber and flanges Diameter of the external chamber Measurement range Process connection Top of chamber, vent Stainless steel, Hastelloy, Monel According to pressure and From 100 to mm Flanges: EN , DIN 2526, ANSI/ASME B16.5, ГОСТ , ГОСТ Р Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5 Flat, semi circular top, flange, plug, valve, fittings For details see type list B2 Magnetic roller indicator Local indication by pointer Scale Limit switch Electrical output Insulation / heating mm, cm, %, optional SPJ NAMUR, SPDT, min, max SP ma, HART, FIELDBUS, PROFIBUS, SP4/M OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI Other specifications on request 30 of 61

31 B Advanced configuration 31 of 61

32 B1 Float for bypass level indicator L21 Medium From 196 C to +500 C Metal float Plastic float Nominal pressure From 1 to 400 bar g Density of the medium 350 kg/cm 3 External material of the bypass chamber and flanges Diameter of the float Float material Stainless steel, Hastelloy, Monel 50 x 0,5 (1), 50,8 x 0,8 (1,27) Stainless steel, titanium, PP, PVC, PVDF, ETFE Float dimensions and dependence on the density The float type, its length and diameter are chosen according to specific media parameters and operating conditions. The float has the same serial number as magnetic level indicator. For illustration we present a table of dimensions for selected densities in the most widely used type of float (stainless steel, Ø50 mm, PN16). Float length (mm) Medium density (kg/m 3 ) Scale Local indication Float Changes of the operating conditions (, pressure, density) causes shift of the measuring edge, depending on the density of the liquid. If we know the density we can correct it by moving the scale and sensors. Optionally it is possible the float for different densities supply with weight. Float material: Stainless steel DIN , DIN , titanium, PP, PVC, PTFE, full composite design. Materials magnetic coupling: samarium cobalt, neodymium boron. They are powerful magnetic materials. We use AlNiCo material for high. Maximum float speed at which is a local indicator function is up to 1,5 m/s. Indication level 32 of 61

33 B2 Standard options for top of chamber Cap Flat Flat with plug, hex screw Flat with plug, hex wrench T1 T2 T3 T4 Flat with tabular end for Flat vent flange Flat with needle valve Flat top with doubled welding valves T5 T6 T7 T8 Flat with flange with Flat with flange with plug valve Flat with ball valve G / NPT Flange with vent flange T9 T10 T11 T12 Flange with ball Flange with tabular end Compact flange PN63 Compact flange PN250 valve G / NPT for welding T13 T14 T15 T16 33 of 61

34 B3 Standard options for bottom of chamber Cap Flat Flat with plug, hex screw Flat with tabular end for welding B1 B2 B3 B4 Flat with drain flange Flat with needle valve Flat with doubled valves Flat with ball valve G / NPT B5 B6 B7 B8 Flat with flange with Flange with cylindrical Flange with conical plug Flange with drain flange valve plug B9 B10 B11 B12 Flange with drain valve Flange with tabular end Flange with ball valve Flange with needle for welding G / NPT valve B13 B14 B15 B16 Flange with Compact flange PN63 Compact flange PN250 doubled valves B17 B18 T19 34 of 61

35 B4 Orientation of process connection SS side side The most commonly used option of joining, characterized by simply mounting. Maximal possible range readings / measurements is total distance between connecting pipes (L). TS top side Under this option, the installation in upper range measurement appears "dead zone ", which is equal to the length of the upper pocket (T). Measurement possible to produce by lower connecting nozzle. Ventilation chamber may provide horizontal fitting. SD side down Under this option, the installation in lower range measurement appears "dead zone", which is equal to the length float chamber (U). Measurements possible produce to the top the connecting pipe. For drainage chamber may provide horizontal fitting. TD top down Under this option, the installation in lower range measurement appears "dead zone", which is equal to the length float chamber (U). The the top of the "dead zone" will be equal to the upper pocket (T). For ventilation / drainage chamber may provide horizontal fittings. 35 of 61

36 B5 Process connection type S1 Flat flange S2 Collar flange S3 Collar flange transition diameter S4 Welded pipe S5 Adaptor with male thread S6 Socket with internal thread There are also other types of process connections, such as flanges freely rotatable, quick couplings, Tri Clamp connections and others. 36 of 61

37 B6 Magnetic roller indicator Indicator bar with metal rollers that meet the requirements for outdoor use, resistance to sunlight, resistance to fluctuations dimensional stability and resistance to vibration. Metal rollers have lower pivot friction and therefore display shows lower hysteresis and a bigger margin range (up to 40 mm). For less demanding applications, it is possible to use plastic rollers. IP Standard magnetic roller indicator with plastic rollers red / white up to +100 C With thermal shield PI up to +250 C (other code IP/PI) IM Standard magnetic roller indicator with metal rollers red / white up to +300 C Increased protection degree IP68 With thermal shield PI up to +500 C (other code IM/PI) IC Custom magnetic roller indicator with different colours of rollers e.g. black / yellow (plastic or metal rollers, thermal shield) IS Other option Indicator with traverse magnet AC Acrylic console for cryogenic applications 37 of 61

38 B7 Stainless steel scale SM Stainless steel scale laser engraved in millimeters SC Stainless steel scale laser engraved in centimeters SP Stainless steel scale laser engraved in percent SX Stainless steel scale laser engraved on agreement (for example ) 38 of 61

39 B8 Connecting option DS Upper and lower damper spring OV Shut off valves MB Mounting bracket 39 of 61

40 C Accessories 40 of 61

41 C1 SPJ Limit switch Standard specification Medium From 40 C up to +450 C 44 Ambient From 60 C up to +85 C Accuracy, mm ±5 /±10 / ±15 Protection IP 68 Maximum current Maximum voltage Maximum power Weight Explosion protection 3 A 400 V 100 W 0,4 kg General Purpose 1/2G/A Ex ia IIC T6... T1 Ga/Gb Flameproof sensor allows monitoring of any level. Its location is user adjustable. Sensor has marked switching point. Cable gland must be facing down. Sensor range is up to 45 mm from float chamber allowing placement outside the insulation. Switch is also available in Ex d version. II 2G Ex d IIC T4 T6 Gb II 1G Ex ia IIC T1 T6 Gb Cable 4G x 0,75 external diameter 7,6 mm Standard cable length is 3 m and the cable cannot be shortened in Ex d variant. 41 of 61

42 Manufacturer type number Code 1 Basic type SPJ SPJ Limit swich 2 Sensor placement (if ordered with level indicator) 3 Approval NO NO EXIA Ex ia EXD Ex d 4 Parameter LV LV to 175 V DC; 0,5 A; 10 W SPDT HV HV to 400 V DC; 3 A; 100 W SPDT NAM NAMUR NAML NAMUR LED SP1 Switching max, to 250 V DC; 1 A; 60 W SPST SP2 Switching min, to 250 V DC; 1 A; 60 W SPST Ordering example Basic type Sensor placement Approval Parameter Code SPJ / 500 / EXIA / LV 42 of 61

43 C2 Potentiometric level sensor SP4 Standard specification Medium Ambient From 40 C up to +450 C From 60 C up to +85 C Accuracy, mm ±5 /±10 / ±15 Material probe The diameter of the probe Measurement range The output of sensor Output built in converter Availability display option Explosion protection Stainless steel 14; 20,3 mm Up to 6000 mm Potentiometer 4 20 ma 4 20 ma HART / SIL 2 PROFIBUS PA Foundation FIELDBUS Optional General Purpose 1/2G/A Ex ia IIC T6... T1 Ga/Gb 43 of 61

44 C3 Potentiometric level sensor SP4 in Ex d execution Standard specification Medium Ambient From 40 C up to +250 C From 60 C up to +85 C Accuracy, mm ±5 /±10 / ±15 Material probe The diameter of the probe Measurement range The output of sensor Output built in converter Availability display option Explosion protection Stainless steel 14; 20,3 mm Up to 6000 mm Potentiometer 4 20 ma 4 20 ma HART / SIL 2 PROFIBUS PA Foundation FIELDBUS Optional General Purpose 1/2G/D Ex d IIC T6 T1 Ga/Gb 44 of 61

45 Manufacturer type number Code 1 Basic type SP4 SP4 Electric output 2 Measurement range in mm 3 Resolution 5 5 mm mm mm 4 Approval NO NO EXIA Ex ia EXD Ex d 5 Display DL Local DR Remote 6 Option 4 20mA 4 20 ma HART 4 20 ma HART PB PROFIBUS FF FOUNDATION FIELDBUS Ordering example Basic type Measurement range Resolution Approval Display Option Code SP4 / 500 / 5 / NO / DL / HART 45 of 61

46 C4 Magnetostrictive level sensor SP4/M Standard specification Probe head Protection class IP68 Material Stainless steel 303 M16 x 1.5 cable gland for cable diameter Cable terminal 5 to 10 mm ½ NPT threads for conduit cabling; M12 Connector Ambient 40 C to + 85 C Probe tube Material Stainless steel 316 Ti; Hastelloy C4/C22 Accuracy Filling level Up to ±0.3 mm or ±0.01 % Resolution (HART ) 0.1 mm Electrical connection Connection 2 wire Voltage 8 to 30 V DC, Ex version 10 to 30 V DC Power output: 4 to 20 ma/hart ; Signal Failure mode confirmed with NAMUR NE43 Serial Protocol to connect to LOGI X Float position in mm, cm, m, inches or feet; positioning of second float; separation HART functions layer (difference between floats); sensor status information; remote configuration Process conditions Temperature Up to 450 C Pressure Up to 200 bar Vibration resistant design (to OIML D11) Options ATEX and IECEx approval Qualified for SIL 2 (IEC 61508) 46 of 61

47 Manufacturer type number Code 1 Basic type SP4/M SP4/M Magnetostrictive 2 Measurement range in mm 3 Resolution 02 0,2 mm 05 0,5 mm 4 Approval NO NO EXIA Ex ia 5 Display DL Local DR Remote 6 Option 4 20mA 4 20 ma HART 4 20 ma HART Ordering example Basic type Measurement range Resolution Approval Display Option Code SP4/M / 1000 / 02 / NO / DR / HART 47 of 61

48 C5 EMKOTDR 60 Radar level meters with guided wave Standard specification Supply voltage EMKOTDR 60N (NT) EMKOTDR 60Xi (XiT) EMKOTDR 60Xd (XdT) V DC V DC V DC Output type (var. "I") 4 20 ma (2 wire), HART Output type RS 485 (var. "M") protocol Modbus RTU Basic error for range 2,0 40 m ±2 mm Resolution 1 mm Ambient 30 C +70 C Process 40 C +200 C Process connection thread G1 Process pressure (for temparature +85 C) Protection class for EMKOTDR 60N 10 (20, 30, 33) for EMKOTDR 60N 11 (12) for EMKOTDR 60N bar 0 15 bar 0 5 bar IP67 Device clarification EMKOTDR 60N performance for non explosive area EMKOTDR 60NT high performance for non Ex / Ex areas EMKOTDR 60Xi (XiT) II 1/2 G Ex ia IIB T5 Ga/Gb EMKOTDR 60Xd (XdT) current output II 1 D Ex ta IIIC T85 T300 C Da output RS 485 II 1 D Ex ta IIIC T100 T300 C Da Guided wave radar level measurement The function principle of the impulse radar (microwave) level meter is TDR (Time Domain Reflectometry). The electronics transmits very short electrical pulses (0.5 ns), which are linked to a one wire transmission line (measuring electrode). Measuring electrode can be created of rod or rope. The pulse propagates along the electrode in the form of electromagnetic wave toward the level surface, where it is partly reflected and the reflected component is returned to the receiving module of the electronics. The electronics measures the time of flight of electromagnetic wave and appropriately sets the value of the output signal. The method is resistant against changes in the atmosphere (pressure,, dust, steam) and to changes in medium parameters (change in dielectric constant, conductivity). Suited to continuous level measurement of various liquids, mush and bulk solid materials. Radar level meter with guided wave (TDR) Universal use, direct mounting into containers, silos, vessels, reservoirs, etc. Stainless steel rod or rope electrode Measurement range up to 40 m Xi, XiT versions for usage in explosive areas, or Xd, XdT versions for usage in flamable dusts areas Linear measurement also in non conductive and in variously shaped tanks Immediate view measured values on the display Simple installation and settings Current output ( ma) with HART protocol or output RS 485 Modbus 48 of 61

49 C6 EMKOCAP 25 Capacitive level meters Standard specification Supply voltage current output (var. I ) V DC voltage output (var. U ) V DC Output type (var. I ) ma (2 wire) Output type (var. U ) V (3 wire) Accuracy (from full measured range) 1% Ambient 40 C C Temperature range on electrode 40 C C Process connection thread M27x2 ; M30x1,5 ; G ¾ ; NPT ¾; TriClamp Protection class IP67 For continuous level measurement of liquid and bulk solid materials. Direct mounting into containers, vessels, basins, reservoirs, etc. Possibility of linear measurements even in non conductive and differently shaped containers Simple sensitivity setting by means of magnetic pen LED state and function indication Wide choice of electric connection via connectors, cable glands, or protective conductor Material of housing and rod electrodes from stainless steel EMKOCAP 26 Capacitive level meters Standard specification Supply voltage current output (var. I ) V DC voltage output (var. U ) V DC Output type (var. I ) ma (2 wire) Output type (var. U ) V (3 wire) Accuracy (from full measured range) 1% Ambient 40 C C Temperature on electrode 40 C C Process connection thread M36 2; G 1"; TriClamp Protection class IP65 / IP67 For continuous level measurement of liquid and bulk solid Direct mounting into containers, silos, vessels, basins, reservoirs, etc. Possibility of linear measurements even in non conductive and differently shaped containers Selectable measurement ranges Easy and quick connecting by connector Continuous adjustment of initial capacity Xi version for usage in explosive areas Material of housing and rod electrodes from stainless steel 49 of 61

50 C7 Thermal insulation Standard specifications Medium The material of the outer shell insulation Diameter of the external chamber Operating range pointer Up to +130 C for Armaflex foam Up to +500 C for basalt wool Up to C for Sibrex ceramic ins. Stainless steel / Armaflex foam No restriction No restriction PI preparation for insulation Vent Drain Range of regulated Scale Order code Removable box for ventilation / plug Removable box for drainage From 196 to +400 C On two scales can be applied different units AFI, SAI, SCI, PI AFI Armaflex foam insulation SAI stainless steel angular insulation SCI stainless steel circular insulation full cover 50 of 61

51 C8 Electrical heating with thermal insulation OE Standard specifications Medium The material of the outer shell insulation Diameter of the external chamber Operating range pointer Vent Up to +130 C for the foam rubber Up to +500 C for basalt wool Stainless steel No restriction No restriction Removable box for ventilation / plug OE / SCI Drain Range of regulated Scale Insulation code Removable box for drainage From +5 to +250 C On two scales can be applied different units AFI, SCI, SAI, PI Order code OE Self regulating heating cable supporting electrical heating freeze protection, maintenance (tempering) safe and reliable, without overheating or burn, simple design, no complex calculations flexible, extendable on site in potentially explosive atmospheres (Ex) QTRV Outputs from 38 to 64 W/m (at 10 C) Max. : 110 C (always on) without overheating or burnout KTV Outputs from 16 to 65 W/m (at 10 C) Max. : 150 C (always on) suitable for steam flushing VPL Outputs from 15 to 61 W/m (at 10 C) Max. : 230 C (always on) suitable for steam flushing 51 of 61

52 C9 Heating jacket (steam, water) with insulation Standard specifications Medium The material of the outer shell insulation Diameter of the external chamber Operating range pointer Vent Up to +130 C for the foam rubber Up to +500 C for basalt wool Stainless steel No restriction No restriction Removable box for ventilation / plug OP Drain Range of regulated Scale Insulation code Removable box for drainage Depending on the type of coolant On two scales can be applied different units AFI, SCI, SAI, PI Order code OP, OPTA, OPTB OPTA / SCI OPTB / SCI 52 of 61

53 C10 Signal transducers of level or Ambient Input range Accuracy Output signal Display Explosion protection From 40 C tо +85 C kω ±0,1% of the measurement range 4 20 mа no General Purpose 0 Ex ia IIC T6 T1 Ga 53 of 61

54 L21 Manufacturer type number Code 1 Basic type L21 Magnetic Level Indicator L21/3 Magnetic Level Indicator top mounted with a float on a string L21/4 Magnetic Level Indicator top mounted with a float on a rod L21/5 Buoyancy Level Indicator L21/C Magnetic Level Indicator for containers 2 Distance centre to centre in mm 3 Orientation of process connection SS Side side TS Top side SD Side down TD Top down 4 Process connection S1 Flat flange DN.. PN.. S4 Welded pipe Do (outer diameter) x S (wall thickness) S2 Collar flange DN.. PN.. S5 Adaptor with male thread G, M, NPT dimension S3 Collar flange transition diameter DN.. PN.. S6 Socket with internal thread 5 Facing types A, B, C, D, E, F, G, H (EN ) RF, SF, FF, RTJ, SG, LG, SM, SF (ASME B16.5) 1, 2, 3, 4, 5, 6, 7, 8, 9 (GOST ) A, B, C, D, E, F, J, K, L, M (GOST P ) 6 Top of chamber / vent T1 Cap T7 Flat with needle valve T13 Flange with ball valve G / NPT T2 Flat T8 Flat with doubled valves T14 Flange with with tabular end for welding T3 Flat with plug, hex screw T9 Flat with ball valve G / NPT T15 Compact flange PN63 T4 Flat with plug, hex wrench T10 Flat with flange with plug T16 Compact flange PN250 T5 Flat with tabular end for welding T11 Flat with flange with valve T6 Flat vent flange T12 Flange with vent flange 7 Bottom of chamber / drain B1 Cap B8 Flat with ball valve G / NPT B15 Flange with ball valve G / NPT B2 Flat B9 Flat with flange with valve B16 Flange with needle valve B3 Flat with plug, hex screw B10 Flange with cylindrical plug B17 Flange with doubled valves B4 Flat with tabular end for welding B11 Flange with conical plug B18 Compact flange PN63 B5 Flat with drain flange B12 Flange with drain flange B19 Compact flange PN250 B6 Flat with needle valve B13 Flange with drain valve B7 Flat with doubled valves B14 Flange with tabular end for weld. 8 Material of chamber N Stainless steel PE Polyethylene PP Polypropylene ETFE Ethylene tetrafluoroethylene PVDF Polyvinylidene fluoride Other material 9 Approval NO Normal environment EX Explosive environment 10 Magnetic roller indicator IP Standard magnetic roller indicator with plastic rollers IM Standard magnetic roller indicator with metal rollers IC Custom magnetic roller indicator IS Indicator with traverse magnet AC Acrylic console for cryogenic applications 11 Scale SM SST laser engraved in millimeters SC SST laser engraved in centimeters SP SST laser engraved in percent SX SST laser engraved on agreement 12 Heating OE Electrical heating OP Heating jacket (water, steam) OPTA Heating jacket (water, steam), U shaped tube OPTB Heating jacket (water, steam), simple tube 13 Insulation AFI Armaflex foam SAI Stainless steel angular SCI Stainless steel circular PI Preparation for insulation (thermal shield) 14 Option DS Upper and lower damper spring OV Shut off valves 54 of 61

55 MB Mounting bracket ZO Special design pollutant, sediment and crystallizing liquids Ordering example Basic type Distance centretocentre Orientation of process connection Process connection Facing Top of chamber / vent Bottom of chamber / drain Material of chamber Approval Magnetic roller indicator Scale Heating Insulation Option Code S1DN25 L21 / 2500 / SS / / B1 / T2 / B2 / N / NO / IM / SM / OE / SCI / MB PN16 Ordering When ordering please specify: Type of medium, concentration in %, the content of mechanical and ferromagnetic impurities Density and viscosity Temperature and pressure (operating and maximal) Measurement range Units Requirements for the electrical outputs Installation Before you install the device, check that the measuring body doesn t contain any impurities Careful when inserting the float into its proper position, the upper part has two indentations at a distance of 6 mm from each other Sealing must be centered in the flanges and threads Fittings can be tighten by torque specified for the operating pressure in the tanks Each unit is pressure tested 1.5 times of the operating pressure, which is specified in the order, the float is only tested 1.3 times of the pressure Check the operating data on level meter label if that correspond to the measured liquid Before commissioning, make sure the drain and air plugs, drain and air valves are closed Open the shut off valve at the meter connecting flanges, first upper valve Now it s ready for measurement Avoid pressure surges and abrupt changes in level risk of float damage During handling with the level indicator it s necessary to avoid abrupt changes in position so that the float chamber due to the acceleration of gravity moved as slowly as possible in order to prevent impact damage. It s recommended to separate level meter from the vessel by valves Maintenance During normal operation device does not require special maintenance. Operation focuses only on checking for leaks, or contaminated liquids in measuring the periodic draining or flushing the measuring tube, or cleaning float. During this activity follow appropriate safety, fire and environmental measures. Electrical connection may only be performed by an authorized person. 55 of 61

56 Appendix 1 EN facing types 56 of 61

57 Appendix 2 ASME B16.5 facing types Raised face Lap joint Large male and female Small male and female Large tongue and groove Small tongue and groove Flat face Flange with welding pipe Ring joint Small male and female 57 of 61

58 Appendix 3 GOST , GOST P facing types 58 of 61

L21 Magnetic Level Indicator

L21 Magnetic Level Indicator L21 Magnetic Level Indicator Float magnetic level meter for continuous level measurement of liquids - Remote data transmission - Use in potentially explosive atmospheres - Robust and versatile design -

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

TORRIX Magnetostrictive level sensor

TORRIX Magnetostrictive level sensor TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications

More information

Capacitive level sensors CLS 23

Capacitive level sensors CLS 23 For level detection of electrically conductive and non-conductive liquids Compact miniature performance for direct mounting to vessels, tanks, sumps and tubes Easy setting by means of magnetic pen SIL

More information

BM 26 BASIC/ADVANCED Technical Datasheet

BM 26 BASIC/ADVANCED Technical Datasheet BM 26 BASIC/ADVANCED Technical Datasheet Magnetic bypass Level Indicator (MLI) for generalpurpose applications Best price / performance ratio Full stainless steel construction IP68 local indicator with

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

BM 26 BASIC/ADVANCED Technical Datasheet

BM 26 BASIC/ADVANCED Technical Datasheet BM 26 BASIC/ADVANCED Technical Datasheet Magnetic bypass Level Indicator (MLI) for generalpurpose applications Best price / performance ratio Full stainless steel construction IP 68 local indicator with

More information

Bypass level indicator With magnetic display Model BNA for nuclear power plants

Bypass level indicator With magnetic display Model BNA for nuclear power plants Level measurement Bypass level indicator With magnetic display Model BNA for nuclear power plants KSR data sheet BNA for NPP Applications Continuous level indication without power supply Indication of

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

Magnetic Level Gauges

Magnetic Level Gauges Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Fluid Control

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

K - Flow Meter with Float

K - Flow Meter with Float K - Flow Meter with Float Doc. no.: 18, en_cat_k, 12/2014, rev. 1 Application All-metal flow meters with float type K are used for signaling and measuring of instant flow, flowed volume of liquid and fluent

More information

MA-400M. Features. Mini-Bypass Magnetic Level Gauge. Description: Application:

MA-400M. Features. Mini-Bypass Magnetic Level Gauge. Description: Application: MA-400M Mini-ypass Magnetic Level Gauge Description: Features / Low-cost design / For simple applications / Up to 5 meter measuring length / Up to +6 bar / Up to +150 C liquid temperature / Flange, thread

More information

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products Data sheet DS/MW05-EN Rev. C MW05 MagWave Magnetic Level Gauge Dual chamber level system K-TEK Products Multiple Chamber Styles 24 Preconfigured Styles Plus Custom Styles Left Hand or Right Hand Mounted

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for general application, Type Series CI4300 Features Differential pressure transmitter with metallic diaphragm High-resolution graphic display with

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. DMK P Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

POSITIONERS and Controls for Complete Valve Automation

POSITIONERS and Controls for Complete Valve Automation CONTROLS A Division of AT Controls Pneumatic & Electro-Pneumatic POSITIONERS and Controls for Complete Valve Automation 1 SS SERIES SS Features Easy and quick auto-calibration Detecting RA (reverse acting)

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Magnetic Level Gauges

Magnetic Level Gauges Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Klinger

More information

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4 Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES Technical Information TI 240F/00/en Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES Compact capacitive level probes (with European certificates). Fully and partially insulated rod and

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for high static working pressure, PN 160, Type series CI4340 Features Simultaneous display of differential pressure and static pressure Long-term stability

More information

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS AP1000-2000 Airpower positioners are a robust range of rotary or linear valve positioners in AP1000 electro-pneumatic (4-20mA), AP1200 pneumatic (3-15 psi) or AP2000 programmable smart type. Designed to

More information

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE The PYRP-28 pressure transmitter is suitable for the measurement of pressure, vacuum and absolute pressure of gases, vapours and liquids for industrial

More information

Industrial OG meter series IOG Inline and flanged oval gear meter

Industrial OG meter series IOG Inline and flanged oval gear meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Industrial OG meter series IOG Inline and flanged oval

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview. SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse frequency shift capacitance level

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in

More information

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet

More information

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD Features UFM 600 up to 6 metres UFM 200 up to 2 metres for distance, volume and filling level measurement for containers, open basins or channels

More information

CAPACITIVE LEVEL SENSORS DLS 27

CAPACITIVE LEVEL SENSORS DLS 27 CAPACITIVE LEVEL SENSORS DLS 27 For limit level sensing of liquid, and bulk-solid and powder materials Xi version for usage in explosive areas Direct mounting into various containers, silos, vessels, tanks,

More information

Level switches Series LC40 Float level switch for liquids

Level switches Series LC40 Float level switch for liquids Level switches Series LC40 Float level switch for liquids Simple and robust construction Versatile and easily adaptable to the different control positions of the industrial processes Side or top of the

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up

More information

Continuous level measurement Capacitance transmitters

Continuous level measurement Capacitance transmitters Siemens AG 2011 Level Measurement SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse

More information

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by

More information

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194. Hydrostatic Continuous level measurement Pressure Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194 185 Hydrostatic Level and pressure measurement Measuring principle

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

Flap-Type Flow Meter Prall

Flap-Type Flow Meter Prall Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional

More information

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions

More information

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications Level Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications WIKA data sheet LM 20.03 Applications Food and beverage industry Pharmaceutical industry

More information

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters System 6000 Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters Edition April 2018 Information Sheet T 6000 EN Electropneumatic Converters i/p converters

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40 Mechatronic pressure measurement Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40 WIKA data sheet PV 17.19 Applications weitere Zulassungen

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available Explosion Proof Flowswitch with In-line Flow Key Features Well suitable for corrosive and noncorrosive liquids or gases UL recognized for hazardous location ATEX certified for intrinsic safety and encapsulation

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP

More information

Magnetic Float Switches horizontal 1003-h

Magnetic Float Switches horizontal 1003-h Magnetic Float Switches horizontal 1003-h Table of contents Index Table of contents 82 Description and function 83 Certificates / Approvals 84-85 Magnetic Float Switch horizontally mounted 1003-h Stainless

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for diaphragm seal operation, Type series CI4330 Features Application area General process engineering Chemical and petrochemical industry General process

More information

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors

More information

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0. Differential Pressure Transmitter for Process Industry with HART Communication accuracy according to IEC 60770: 0.075 % FSO Differential pressure from mbar up to 0 bar Static pressure max. Output signal

More information

Level Measurement based on Archimedes Principle. Device Description

Level Measurement based on Archimedes Principle. Device Description Level Measurement based on Archimedes Principle BA Device Description Contents 1 IDENTIFICATION...4 1.1 Supplier/manufacturer...4 1.2 Product type...4 1.3 Product name...4 1.4 Issue date...4 1.5 Version

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Flow meter Type Recordall (RCDL)

Flow meter Type Recordall (RCDL) Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Flow meter Type Recordall (RCDL) Bronze model Features

More information

Process Automation. Sensors and Systems: Level Sensors Level Detectors Overfill Prevention. Process Automation. Accuracy.

Process Automation. Sensors and Systems:   Level Sensors Level Detectors Overfill Prevention. Process Automation. Accuracy. Process Automation Process Automation Accuracy Level Sensors Level Detectors Overfill Prevention Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable, Universal Solutions

More information

Resistance thermometer Model TR10-E, for additional thermowell

Resistance thermometer Model TR10-E, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry

More information

Reed sensor For bypass level indicators Model BLR

Reed sensor For bypass level indicators Model BLR Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 Applications Sensor for continuous level measurement of liquids in bypass level indicators Chemical and petrochemical

More information

Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry

Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry Hot bearing WARNING device, for use in hazardous areas Installation guide PT100V3C Bearing Temperature Sensor With Grease nipple 1/2

More information

OPTIMASS 2000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics

More information

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure

More information

Masoneilan Series

Masoneilan Series Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2004 7.02445.24.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel Status: 10/99 Status: 10/99 One tube no limits No limits with

More information

OPTIFLUX Electromagnetic Flow Sensor

OPTIFLUX Electromagnetic Flow Sensor OPTIFLUX 2000 Technical Datasheet Electromagnetic Flow Sensor Engineered and manufactured for the water and wastewater industry All relevant approvals for potable water Long-term reliability and durability

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

Turbine flowmeters Series TM

Turbine flowmeters Series TM Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,

More information

SATRON VDt Differential Pressure Transmitter

SATRON VDt Differential Pressure Transmitter SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

OPTISWITCH 4000/5000. Vibration level switches for liquids

OPTISWITCH 4000/5000. Vibration level switches for liquids OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring

More information

The filling level sensors are designed in accordance to the following standards

The filling level sensors are designed in accordance to the following standards Instructions according to Portaria N 179/2010 UL-BR 17.0706 Filling Level Sensors type VISY-Stick and type TORRIX Ex Version: 09.2017 I Range of application The filling level sensors are designed for continuous

More information

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description edit. II 2015/ page 1 Level switches (two-term level controllers) ERH-xx-04,-06,-07,6,6.1 Description The limit level signalling or two-term liquid level control in the open or closed pressure tanks. The

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Features of the FAFNIR technology

Features of the FAFNIR technology VISY-Stick The level and environmental sensor based on the magnetostrictive measuring principle VISY-Stick is a level and environmental sensor that has been specially designed to offer highprecision volume

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

Absolute pressure gauge with diaphragm

Absolute pressure gauge with diaphragm Absolute pressure gauge with diaphragm and switch function,type series BF2 Features Absolute pressure gauge with diaphragm and switch function Nominal ranges 0 60 mbar abs to 0 2500 mbar abs With integrated

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information