BS-TB-004EB February TA Rotor. Used in the Beckman Coulter Allegra 25R and TJ-25 Centrifuges Beckman Coulter, Inc.

Size: px
Start display at page:

Download "BS-TB-004EB February TA Rotor. Used in the Beckman Coulter Allegra 25R and TJ-25 Centrifuges Beckman Coulter, Inc."

Transcription

1 BS-TB-004EB February 2014 TA Rotor Used in the Beckman Coulter Allegra 25R and TJ-25 Centrifuges Beckman Coulter, Inc.

2 SAFETY NOTICE This safety notice summarizes information basic to the safe use of the rotor described in this manual. The international symbol displayed above is a reminder to the user that all safety instructions should be read and understood before operation or maintenance of this equipment is attempted. When you see the symbol on other pages of this publication, pay special attention to the safety information presented. Observance of safety precautions will also help to avoid actions that could damage or adversely affect the performance of the rotor. Handle body fluids with care because they can transmit disease. No known test offers complete assurance that such fluids are free of micro-organisms. Some of the most virulent Hepatitis (B and C) viruses, HIV (I V), atypical mycobacteria, and certain systemic fungi further emphasize the need for aerosol protection. Handle other infectious samples according to good laboratory procedures and methods to prevent spread of disease. Because spills may generate aerosols, observe proper safety precautions for aerosol containment. Do not run toxic, pathogenic, or radioactive materials in this rotor without taking appropriate safety precautions. Biosafe containment should be used when Risk Group II materials (as identified in the World Health Organization Laboratory Biosafety Manual) are handled; materials of a higher group require more than one level of protection. The rotor and accessories are not designed for use with materials capable of developing flammable or explosive vapors. Do not centrifuge such materials in nor handle or store them near the centrifuge. This rotor was developed, manufactured, and tested for safety and reliability as part of a Beckman Coulter centrifuge/rotor system. Its safety or reliability cannot be assured if used in a non-beckman Coulter centrifuge or in a Beckman Coulter centrifuge that has been modified without Beckman Coulter s approval. Although rotor components and accessories made by other manufacturers may fit in the TA rotor, their safety in this rotor cannot be ascertained by Beckman Coulter. Use of other manufacturers components or accessories in the TA rotor may void the rotor warranty and should be prohibited by your laboratory safety officer. Only the components and accessories listed in this publication should be used in this rotor. Make sure that filled containers are loaded symmetrically into the rotor and that opposing bottles or tubes are filled to the same level with liquid of the same density. If disassembly reveals evidence of leakage, you should assume that some fluid escaped the rotor. Apply all appropriate safety and decontamination procedures to the centrifuge and accessories as required. Never exceed the maximum rated speed of the rotor and labware in use. Refer to the section on RUN SPEEDS. Do not use sharp tools on the rotor that could cause scratches in the rotor surface. Corrosion begins in scratches and may open fissures in the rotor with continued use. 2

3 TA ROTOR 25 rav rmin rmax Axis of Rotation SPECIFICATIONS Maximum speed rpm Density rating at maximum speed g/ml Critical speed range* to 700 rpm Relative Centrifugal Field* at maximum speed At r max (96.0 mm) g At r av (64.5 mm) g At r min (33.0 mm) g Conditions requiring speed reductions see RUN SPEEDS Maximum imbalance of opposing loads grams Number of tube cavities Available bottles and tubes see Table 1 Nominal tube dimensions mm Nominal tube capacity (largest tube) ml Nominal rotor capacity ml Approximate acceleration time to maximum speed (fully loaded) sec Approximate deceleration time from maximum speed (fully loaded) sec Weight of fully loaded rotor kg (12.70 lb) Rotor and lid material aluminum *The critical speed range is the range of speeds over which the rotor shifts so as to rotate about its center of mass. Passing through or running at the critical speed range is characterized by some vibration. Relative Centrifugal Field (RCF) is the ratio of the centrifugal acceleration at a specified radius and speed (rω 2 ) to the standard acceleration of gravity (g) according to the following formula: RCF = rω g where r is the radius in millimeters, ω is the angular velocity in radians per second (2 π RPM /60), and g is the standard acceleration of gravity (9807 mm/s 2 ). After substitution: RCF = 1.12 r RPM

4 DESCRIPTION O-ring (393505) Lid (368304) Rotor Body This rotor has been manufactured in an ISO 9001 or facility for use with the specified Beckman Coulter centrifuges. The TA-14-50, rated for rpm, is a fixed angle rotor designed to centrifuge up to eight 50-mL bottles at a 25-degree angle to the axis of rotation. Used in Beckman Coulter Allegra 25R and TJ-25 centrifuges, the rotor develops centrifugal forces that can efficiently pellet cells from large volumes, or cell particles from tissue homogenates. Short column methods (such as partially filled tubes) may also be used to purify large quantities of virus in a cushion gradient. The rotor and lid are made of aluminum and are anodized for corrosion resistance the rotor is black and the lid is blue. A lubricated O-ring in the rotor maintains atmospheric pressure in the rotor during centrifugation. A tie-down screw is used to secure the rotor to the centrifuge drive hub. The centrifuge identifies rotor speed during the run by means of a magnetic speed sensor system in the rotor chamber and magnets imbedded in the rotor. The overspeed system ensures that the rotor does not exceed its permitted speed. Refer to the Warranty at the back of this manual for warranty information. PREPARATION AND USE Specific information about the TA rotor is given here. Information about the centrifuge is contained in the centrifuge manual, which should be used together with this manual for complete centrifuge, rotor, and accessory operation. NOTE Although rotor components and accessories made by other manufacturers may fit in the TA rotor, their safety in this rotor cannot be ascertained by Beckman Coulter. Use of other manufacturers components or accessories in the TA rotor may void the rotor warranty and should be prohibited by your laboratory safety officer. Only the components and accessories listed in this publication should be used in this rotor. 4

5 PRERUN SAFETY CHECKS Read the SAFETY NOTICE at the front of this manual before using the rotor. 1. Make sure that the rotor, lid, and all tubes or bottles and accessories are clean and show no signs of corrosion or cracking. 2. If fluid containment is required, use capped bottles or tubes. All containers carrying physiological fluids should be capped, and not overfilled, to prevent leakage. Verify that the bottles or tubes being used are listed in Table Check the chemical compatibilities of all materials used (refer to Chemical Resistances, publication IN-175). ROTOR PREPARATION For runs at other than room temperature, refrigerate or warm the rotor before the run for fast equilibration. 1. Be sure that the metal threads in the rotor are clean and lightly but evenly coated with Spinkote lubricant (306812). 2. Load the filled containers symmetrically into the rotor (see page 7 for tube and bottle information). If fewer than eight tubes are being run, they must be arranged symmetrically in the rotor (see Figure 1). Opposing tubes must be filled to the same level with liquid of the same density. 3. Put the lid in place and tighten it by hand. Figure 1. Typical Examples of Arranging Bottles or Tubes in the Rotor. Two, four, six, or eight containers can be centrifuged per run, if they are arranged in the rotor as shown. 5

6 OPERATION Precool the rotor in the centrifuge or in a refrigerator before use especially before short runs to ensure that the rotor reaches the set temperature. A suggested precooling cycle is a minimum of 30 minutes at 2000 rpm with the temperature set at 0 C. NOTE Temperatures may vary slightly between centrifuges. If sample temperature is crucial, test temperature settings on your instrument using water samples. For runs at other than room temperature, refrigerate or warm the rotor beforehand for fast equilibration. 1. Ensure that the rotor tie-down screw (368245) is in good condition and the threads are free of foreign matter. CAUTION Do not drop the rotor onto the drive shaft. The shaft can be bent or damaged if the rotor is forced sideways or dropped onto the shaft. 2. Center the rotor over the drive shaft and carefully lower it straight down. 3. Secure the rotor to the drive shaft with the tie-down screw. Tighten the screw by turning it to the right (clockwise) with the T-handle rotor wrench (368246). 4. Refer to the instrument instruction manual for centrifuge operation. See RUN SPEEDS, page 9, for information about speed limitations. 6

7 REMOVAL AND SAMPLE RECOVERY CAUTION If disassembly reveals evidence of leakage, you should assume that some fluid escaped the rotor. Apply appropriate decontamination procedures to the centrifuge and accessories. 1. Using the T-handle rotor wrench, turn the tie-down screw to the left (counterclockwise) to release the rotor. 2. Remove the rotor by lifting it straight up and off the drive shaft. 3. Remove the rotor lid and remove tubes or bottles. BOTTLES AND TUBES The TA rotor uses the bottles and tubes listed in Table 1. Be sure to use only those items listed and observe the maximum fill volumes and speed limits shown. (Maximum fill volume is the maximum amount of fluid that can be centrifuged in the listed container.) To minimize the possibility of leakage from capped tubes or bottles, load the containers with sample, secure the caps, and precool the loaded labware to run temperature before beginning the run. Refer to Chemical Resistances for information on the chemical compatibilities of labware materials. Temperature Limits Plastic containers have been centrifuge tested for use at temperatures between 2 and 25 C. For centrifugation at other temperatures, pretest containers under anticipated run conditions. If plastic containers are frozen before use, make sure that they are thawed to at least 2 C before centrifugation. 7

8 Table 1. Available Bottles and Tubes for the TA Rotor. Use only the items listed here and observe fill volumes and maximum run speeds. Dimensions and Volume Tube Description Part Number Max. Fill Volume a (ml) Required Accessory Description Part Number Max Speed b / RCF mm 50 ml polypropylene bottle w/cap assembly (pkg/24) 40 none rpm g mm 50 ml polycarbonate bottle w/cap assembly (pkg/24) 40 none rpm g mm 50 ml polycarbonate bottle, screw-on cap (pkg/25) 38.5 none rpm g mm 50 ml polypropylene bottle, screw-on cap (pkg/25) 38.5 none rpm g mm 50 ml polycarbonate thickwall tube, snap-on cap (pkg/25) 36.5 white 29-mm cap red 29-mm cap green 29-mm cap yellow 29-mm cap blue 29-mm cap c c c c c rpm g mm 50 ml polypropylene thickwall tube, snap-on cap (pkg/25) 36.5 white 29-mm cap red 29-mm cap green 29-mm cap yellow 29-mm cap blue 29-mm cap c c c c c rpm g mm 50 ml mm 50 ml polycarbonate tube (pkg/25) polypropylene tube (pkg/25) 36.5 none rpm g 36.5 none rpm g a Above 20 C fill polypropylene tubes at least half full. Containers may be filled less than or equal to the maximum fill volumes provided here. b Maximum speeds listed are guidelines only. These speeds have been achieved in reliability tests at Beckman Coulter, but because of manufacturing variances no guarantee of performance or fit is expressed or implied. c Package of 25. Thickwall Tubes Thickwall polypropylene and polycarbonate tubes can be run partially filled (at least half filled) with or without caps, but all opposing tubes for a run must be filled to the same level with liquid of the same density. Do not overfill capless tubes; be sure to note the fill volumes and run speeds shown in Table 1. 8

9 Polycarbonate and Polypropylene Bottles Capped polycarbonate and polypropylene bottles can be run partially filled (not less than half full). Again, all opposing containers for a run must be filled to the same level with liquid of the same density. RUN SPEEDS SPEED The centrifugal force at a given radius in a rotor is a function of speed. Comparisons of forces between different rotors are made by comparing the rotors relative centrifugal fields (RCF). When rotational speed is adjusted so that identical samples are subjected to the same RCF in two different rotors, the samples are subjected to the same force. The RCF at each speed is automatically calculated by the centrifuge software; if the RCF is entered, the centrifuge calculates the equivalent revolutions per minute (rpm). The maximum run speed listed in the rotor specifications is for operation when all conditions are within the standard specifications. Speeds must be reduced under the following circumstances: When certain glass or plastic tubes are used, reduce rotor speed to prevent tube breakage. Follow the manufacturers recommendations regarding maximum speed capacity for the tubes. Because the strength of tubes can vary between lots, and depend on handling and usage, Beckman Coulter highly recommends that you pretest these tubes in this rotor (using water instead of valuable sample) to determine optimal operating conditions. If nonprecipitating solutions more dense than 1.2 g/ml are centrifuged, the maximum allowable run speed must be reduced according to the following equation: reduced maximum speed = ( rpm) 1.2 g/ml ρ where ρ is the density of the tube contents. This speed reduction will protect the rotor from excessive stresses due to the added tube load. Note, however, that the use of this formula may still produce maximum speed figures that are higher than the limitations imposed by the use of certain tubes or adapters. In such cases, use the lower of the two figures. 9

10 Further speed limits must be imposed when self-forming-gradient salts are centrifuged, as the equation does not predict concentration limits/speeds that are required to avoid precipitation of salt crystals. CARE AND MAINTENANCE NOTE If glass tubes break, remove the glass very carefully from the adapter or cavity. Imbedded glass particles that remain in cavities or adapters can cause tube failure during subsequent runs. MAINTENANCE Check for Corrosion O-ring (393505) Lid (368304) Rotor Body Do not use sharp tools on the rotor, as they can scratch the anodized surface. Corrosion begins in scratches and may open fissures in the rotor with continued use. Periodically (at least monthly) inspect the rotor, especially inside cavities, for rough spots, cracks, pitting, white powder deposits (frequently aluminum oxide), or heavy discoloration. If any of these signs are evident, do not run the rotor. Contact your Beckman Coulter representative for information about the Field Rotor Inspection Program and the rotor repair center. Before using the tie-down screw, check it for damage such as stripped threads. Replace it if it is damaged. Regularly apply a thin, even coat of Spinkote lubricant (306812) to the rotor drive hole to prevent rotor sticking. Refer to Chemical Resistances for the chemical compatabilities of rotor and accessory materials. Your Beckman Coulter representative provides contact with the Field Rotor Inspection Program and the rotor repair center. 10

11 CLEANING Wash the rotor and rotor components immediately if salts or other corrosive materials are used or if spillage has occurred. Do not allow corrosive materials to dry on the rotor. Rotor Cleaning Kit (339558) Under normal use, wash the rotor frequently (at least weekly) to prevent buildup of residues. If the rotor is left in the centrifuge for long periods of time, remove it at least once a month for cleaning and lubrication. 1. Remove the O-ring and wash the rotor, lid, and O-ring in a mild detergent, such as Beckman Solution 555 (339555), that won t damage the rotor. The Rotor Cleaning Kit (339558) contains two plastic- coated brushes and two quarts of Solution 555 for use with rotors and accessories. Dilute the detergent 10 to 1 with water. NOTE Do not wash the rotor components or accessories in a dishwasher. Do not soak components in detergent solution for long periods of time, such as overnight. Lid (368304) 2. Rinse the cleaned rotor and components with distilled water. O-ring (393505) 3. Air-dry the rotor and lid upside down. Do not use acetone to dry the rotor. 4. Lightly but evenly lubricate the rotor drive-hole threads with Spinkote (306812). Rotor Body 5. Apply a thin, even coat of silicone vacuum grease (335148) to the O-ring, then replace it in the groove in the outer rim of the rotor. Clean metal threads every 6 months, or as necessary. Use a brush and concentrated Solution 555. Rinse and dry thoroughly, then lubricate lightly but evenly with Spinkote to coat all threads. 11

12 DECONTAMINATION If the rotor (and/or accessories) becomes contaminated with radioactive material, decontaminate it using a solution that will not damage the anodized surfaces. Beckman Coulter has tested a number of solutions and found two that do not harm anodized aluminum: RadCon Surface Spray or IsoClean Solution (for soaking),1 and Radiacwash.2 NOTE IsoClean can cause fading of colored anodized surfaces. Use it only when necessary and remove it promptly from rotor surfaces. While Beckman Coulter has tested these methods and found that they do not damage the rotor or components, no guarantee of sterility or disinfection is expressed or implied. Consult your laboratory safety officer regarding the proper decontamination methods to use. If the rotor or accessories are contaminated with toxic or pathogenic solutions, follow appropriate decontamination procedures. Check Chemical Resistances to be sure the decontamination method will not damage any part of the rotor. STERILIZATION AND DISINFECTION The rotor and all rotor components can be autoclaved at 121 C for up to one hour. Remove the lid from the rotor and place the rotor, lid, and O-ring in the autoclave upside down. Ethanol (70%)3 or hydrogen peroxide (6%) may be used on all rotor components, including those made of plastic. Bleach (sodium hypochlorite) may be used, but may cause discoloration of anodized surfaces. Use the minimum immersion time for each solution, per laboratory standards. 1 In U.S.A., contact Nuclear Associates (New York); in Eastern Europe and Commonwealth States, contact Victoreen GmbH (Munich); in South Pacific, contact Gammasonics Pty, Ltd. (Australia); in Japan, contact Toyo Medic Co. Ltd. (Tokyo). 2 In U.S.A., contact Biodex Medical Systems (Shirley, NY); internationally, contact the U.S. office to find the dealer nearest you. 3 Flammability hazard. Do not use in or near operating centrifuges. 12

13 While Beckman Coulter has tested these methods and found that they do not damage the rotor or components, no guarantee of sterility or disinfection is expressed or implied. When sterilization or disinfection is a concern, consult your laboratory safety officer regarding proper methods to use. Refer to publication IN-192, included in each box of tubes or bottles, for tube and bottle sterilization and disinfection procedures. TUBE BREAKAGE If a glass bottle or tube breaks, remove the glass very carefully from the rotor. Imbedded glass particles that remain in the rotor cavities or adapters can cause tube failure during subsequent runs. Clean the rotor thoroughly immediately following a bottle or tube breakage. STORAGE When the rotor is not in use, store it in a dry environment (not in the centrifuge) with the rotor lid removed to allow air circulation so moisture will not collect in the tube cavities. 13

14 RETURNING A ROTOR RGA Before returning a rotor or accessory for any reason, prior permission (a Returned Goods Authorization form) must be obtained from Beckman Coulter, Inc. This RGA form, which may be obtained from your local Beckman Coulter sales office, should contain the following information: rotor serial number, history of use (approximate frequency of use), reason for the return, original purchase order number, billing number, and shipping number, if possible, name and phone number of the person to be notified upon receipt of the rotor or accessory at the factory, and name and phone number of the person to be notified about repair costs, etc. To protect our personnel, it is the customer s responsibility to ensure that the parts are free from pathogens and/or radioactivity. Sterilization and decontamination must be done before returning the parts. Smaller items (such as tubes, bottles, etc.) should be enclosed in a sealed plastic bag. All parts must be accompanied by a note, plainly visible on the outside of the box or bag, stating that they are safe to handle and that they are not contaminated with pathogens or radioactivity. Failure to attach this notification will result in return or disposal of the items without review of the reported problem. Use the address label printed on the RGA form when mailing the rotor and/or accessories. Customers located outside the United States should contact their local Beckman Coulter office. 14

15 SUPPLY LIST NOTE Publications referenced in this manual can be obtained by calling Beckman Coulter at in the United States, or by contacting your local Beckman Coulter office. Call Beckman Coulter Sales ( in the United States; worldwide offices are listed on the back cover of this manual) for detailed information on ordering parts and supplies. For your convenience, a partial list is given below. REPLACEMENT ROTOR PARTS TA rotor assembly Lid assembly O-ring, rotor (large) O-ring, lid (small) Tie-down screw T-handle rotor wrench SUPPLIES Bottles, tubes, and accessories see Table 1 Spinkote lubricant (2 oz) Silicone vacuum grease (1 oz) Rotor Cleaning Kit Beckman Solution 555 (1 qt)

16 BENCHTOP ROTOR WARRANTY Subject to the conditions specified below and the warranty clause of the Beckman Coulter, Inc., terms and conditions in effect at the time of sale, Beckman Coulter agrees to correct either by repair or, at its election, by replacement, any defects of material or workmanship which develop within seven (7) years after delivery of a benchtop centrifuge rotor to the original buyer by Beckman Coulter or by an authorized representative, provided that investigation and factory inspection by Beckman Coulter discloses that such defect developed under normal and proper use. Should a Beckman Coulter centrifuge be damaged due to a failure of a rotor covered by this warranty, Beckman Coulter will supply free of charge all centrifuge parts required for repair. 2. This warranty is void if the rotor has been subjected to customer misuse such as operation or maintenance contrary to the instructions in the Beckman Coulter rotor or centrifuge manual. 3. This warranty is void if the rotor is operated with a rotor drive unit or in a centrifuge unmatched to the rotor characteristics or operated in a Beckman Coulter centrifuge that has been improperly disassembled, repaired, or modified. 4. Thermoplastic rotors or components used in some benchtop centrifuges are warranted for one (1) year from date of purchase. CONDITIONS 1. Except as otherwise specifically provided herein, this warranty covers the rotor only and Beckman Coulter shall not be liable for damage to accessories or ancillary supplies including but not limited to (i) tubes, (ii) tube caps, (iii) tube adapters, or (iv) tube contents. DISCLAIMER IT IS EXPRESSLY AGREED THAT THE ABOVE WAR- RANTY SHALL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND OF THE WARRANTY OF MERCHANT- ABILITY AND THAT NEITHER BECKMAN COULTER, INC. NOR ITS SUPPLIERS SHALL HAVE ANY LIABILITY FOR SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER ARISING OUT OF THE MANUFACTURE, USE, SALE, HANDLING, REPAIR, MAINTENANCE, OR REPLACE- MENT OF THE PRODUCT. TRADEMARKS Beckman Coulter, the stylized logo, and Optima are trademarks of Beckman Coulter, Inc. and are registered with the USPTO. All other trademarks, service marks, products, or services are trademarks or registered trademarks of their respective holders.

17 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, California U.S.A. Sales and Service: Internet: Printed in USA 2014 Beckman Coulter, Inc. All rights reserved

Instructions for Using Micro Plus Multiwell Plate Carriers

Instructions for Using Micro Plus Multiwell Plate Carriers Litpak 361309 GS6-TB-011EA February 2014 Instructions for Using Micro Plus Multiwell Plate Carriers In Beckman Coulter GH-3.8, GH-3.8A, and JS-4.3 Rotors A B C D E F G H SPECIFICATIONS Maximum speed...................................

More information

Instructions For Use. FA361.5 Fixed-Angle Rotor. For Use in Beckman Coulter Microfuge 20 Series Centrifuges. PN B30182AA June 2013

Instructions For Use. FA361.5 Fixed-Angle Rotor. For Use in Beckman Coulter Microfuge 20 Series Centrifuges. PN B30182AA June 2013 Instructions For Use FA361.5 Fixed-Angle Rotor For Use in Beckman Coulter Microfuge 20 Series Centrifuges PN B30182AA June 2013 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A. B30182AA

More information

Instructions For Use. F301.5 and FX301.5 Fixed-Angle Rotors

Instructions For Use. F301.5 and FX301.5 Fixed-Angle Rotors Instructions For Use F301.5 and FX301.5 Fixed-Angle Rotors For Use in the Beckman Coulter Microfuge 22R (F301.5), Allegra X-22 Series (FX301.5), and Allegra X-30 Series (FX301.5) Centrifuges September

More information

JS-13.1 Swinging Bucket Rotor

JS-13.1 Swinging Bucket Rotor J-TB-036MA February 2014 JS-13.1 Swinging Bucket Rotor Used In Beckman Coulter J2, J6, and Avanti J Series Centrifuges 2014 Beckman Coulter, Inc. Trademarks Beckman Coulter, the stylized logo, and Avanti

More information

Instructions For Use. SX4400 Swinging Bucket Rotor. For Use in the Beckman Coulter Allegra X-30 Series Centrifuges. B01198AC September 2017

Instructions For Use. SX4400 Swinging Bucket Rotor. For Use in the Beckman Coulter Allegra X-30 Series Centrifuges. B01198AC September 2017 Instructions For Use SX4400 Swinging Bucket Rotor For Use in the Beckman Coulter Allegra X-30 Series Centrifuges B01198AC September 2017 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A.

More information

JA-20 Fixed Angle Rotor

JA-20 Fixed Angle Rotor J-TB-003AZ November 2008 JA-20 Fixed Angle Rotor Used In Beckman Coulter J2, J6, and Avanti J Series Centrifuges 2008 2009 Beckman Coulter, Inc. ! SAFETY NOTICE This safety notice summarizes information

More information

JA-10 Fixed Angle Rotor

JA-10 Fixed Angle Rotor J-TB-006BB February 2014 JA-10 Fixed Angle Rotor Used In Beckman Coulter J2, J6, and Avanti J Series Centrifuges 2014 Beckman Coulter, Inc. Trademarks Beckman Coulter, the stylized logo. and Avanti, are

More information

Instructions For Use. JA Ti Fixed-Angle Rotor. For Use in Beckman Coulter J2 and and Avanti J Series Centrifuges (except Avanti J-E)

Instructions For Use. JA Ti Fixed-Angle Rotor. For Use in Beckman Coulter J2 and and Avanti J Series Centrifuges (except Avanti J-E) Instructions For Use JA-30.50 Ti Fixed-Angle Rotor For Use in Beckman Coulter J2 and and Avanti J Series Centrifuges (except Avanti J-E) J-TB-070AN February 2014 Beckman Coulter, Inc. 250 S. Kraemer Blvd.

More information

J-Lite JLA Fixed Angle Rotor

J-Lite JLA Fixed Angle Rotor J-TB-072J September 2008 J-Lite JLA-16.250 Fixed Angle Rotor Used In Beckman Coulter J2 and Avanti J Series Centrifuges 2008 2009 Beckman Coulter, Inc. ! SAFETY NOTICE This safety notice summarizes information

More information

JA-20.1 Fixed Angle Rotor

JA-20.1 Fixed Angle Rotor J-TB-022AT February 2014 JA-20.1 Fixed Angle Rotor Used In Beckman Coulter J2, J6, and Avanti J Series Centrifuges 2014 Beckman Coulter, Inc. Trademarks Beckman Coulter, the stylized logo, and Avanti,

More information

JA-12 Fixed Angle Rotor

JA-12 Fixed Angle Rotor J-TB-051AG July 2009 JA-12 Fixed Angle Rotor Used In Beckman Coulter J2 and Avanti J Series Centrifuges 2009 Beckman Coulter, Inc. ! SAFETY NOTICE This safety notice summarizes information basic to the

More information

Instructions For Use. JA Fixed-Angle Rotor. For Use in Beckman Coulter J2 and Avanti J Series Centrifuges. PN J-TB-056FB February 2014

Instructions For Use. JA Fixed-Angle Rotor. For Use in Beckman Coulter J2 and Avanti J Series Centrifuges. PN J-TB-056FB February 2014 Instructions For Use JA-25.50 Fixed-Angle Rotor For Use in Beckman Coulter J2 and Avanti J Series Centrifuges PN J-TB-056FB February 2014 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A.

More information

J-TB-089AE February JS-5.3 Rotor. Used in Beckman Coulter Avanti J-20 and J-26 Series, and Avanti J-E Centrifuges Beckman Coulter, Inc.

J-TB-089AE February JS-5.3 Rotor. Used in Beckman Coulter Avanti J-20 and J-26 Series, and Avanti J-E Centrifuges Beckman Coulter, Inc. H G F E D C B A 1 2 3 4 5 6 7 8 9 10 11 12 J-TB-089AE February 2009 JS-5.3 Rotor Used in Beckman Coulter Avanti J-20 and J-26 Series, and Avanti J-E Centrifuges 2009 Beckman Coulter, Inc. ! SAFETY NOTICE

More information

Instructions for Using the A-100/18 and A-100/30 Rotors

Instructions for Using the A-100/18 and A-100/30 Rotors AF-TB-009AK February 2014 Instructions for Using the A-100/18 and A-100/30 Rotors In the Beckman Coulter Airfuge Ultracentrifuge 18 A-100/18 rmin rav rmax Axis of Rotation U.S. Pat. No. 3,997,104 SPECIFICATIONS

More information

L5-TB-036AW July Type 45 Ti Rotor. Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Beckman Coulter, Inc.

L5-TB-036AW July Type 45 Ti Rotor. Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Beckman Coulter, Inc. L5-TB-036AW July 2009 Type 45 Ti Rotor Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges 2009 Beckman Coulter, Inc. ! SAFETY NOTICE This safety notice summarizes information basic

More information

Instructions For Use. JS-5.3 Swinging-Bucket Rotor

Instructions For Use. JS-5.3 Swinging-Bucket Rotor Instructions For Use JS-5.3 Swinging-Bucket Rotor For Use in Beckman Coulter Avanti J-26S XP Series, Avanti J-26 XP Series, Avanti JXN-26, and Avanti J-E Centrifuges PN J-TB-089AG March 2014 Beckman Coulter,

More information

Instructions for Using JS-5.2 and JS-4.0 Swinging Bucket Rotors

Instructions for Using JS-5.2 and JS-4.0 Swinging Bucket Rotors J6-TB-006K December 2007 Instructions for Using JS-5.2 and JS-4.0 Swinging Bucket Rotors JS-5.2 Used in Beckman Coulter J6 Series Centrifuges JS-4.0 Used in Beckman Coulter Avanti J-26XP Series and J6

More information

LXL-TB-005AN August Type 90 Ti Rotor. Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Beckman Coulter, Inc.

LXL-TB-005AN August Type 90 Ti Rotor. Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Beckman Coulter, Inc. LXL-TB-005AN August 2009 Type 90 Ti Rotor Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges 2009 Beckman Coulter, Inc. !!!!!!!! SAFETY NOTICE This safety notice summarizes information

More information

JA-18 Fixed Angle Rotor

JA-18 Fixed Angle Rotor FOR USE I J SERIES ISTRUMETS J-TB-035AR February 2014 JA-18 Fixed Angle Rotor BECKMA COULTER SERIAL O. 95U 1077 Made in U.S.A. JA-18 18,000 RPM Used In Beckman Coulter J2, J6, and Avanti J Series Centrifuges

More information

Instructions For Use. Type 70 Ti Fixed-Angle Rotor. For Use in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges

Instructions For Use. Type 70 Ti Fixed-Angle Rotor. For Use in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Instructions For Use Type 70 Ti Fixed-Angle Rotor For Use in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges PN L5-TB-030BA February 2014 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea,

More information

Instructions For Use. J-Lite JLA and JLA Fixed-Angle Rotor Assemblies. For Use in Beckman Coulter Avanti J Series Centrifuges

Instructions For Use. J-Lite JLA and JLA Fixed-Angle Rotor Assemblies. For Use in Beckman Coulter Avanti J Series Centrifuges Instructions For Use J-Lite JLA-8.1000 and JLA-9.1000 Fixed-Angle Rotor Assemblies For Use in Beckman Coulter Avanti J Series Centrifuges PN J-TB-073GA November 2012 Beckman Coulter, Inc. 250 S. Kraemer

More information

Instructions For Use. TLA-110 Fixed-Angle Rotor

Instructions For Use. TLA-110 Fixed-Angle Rotor Instructions For Use TLA-110 Fixed-Angle Rotor For Use in the Beckman Coulter Optima MAX-XP, MAX-TL, MAX, MAX-E, TL, TLX, and TL-100 Tabletop Ultracentrifuges PN TL-TB-019AG February 2014 Beckman Coulter,

More information

Instructions For Use. JS-4.2, JS-4.2SM, and JS-3.0 Swinging-Bucket Rotors

Instructions For Use. JS-4.2, JS-4.2SM, and JS-3.0 Swinging-Bucket Rotors Instructions For Use JS-4.2, JS-4.2SM, and JS-3.0 Swinging-Bucket Rotors JS-4.2 Rotor for Use in Beckman Coulter Avanti J-HC and J6 Series Centrifuges JS-4.2SM Rotor for Use in Beckman Coulter J6 Series

More information

INSTRUCTIONS FOR USING THE GH-3.8A SWINGING BUCKET ROTOR In Beckman Coulter Allegra 6 Series and Spinchron R and DLX Centrifuges

INSTRUCTIONS FOR USING THE GH-3.8A SWINGING BUCKET ROTOR In Beckman Coulter Allegra 6 Series and Spinchron R and DLX Centrifuges GS6-TB-017EB September 2016 INSTRUCTIONS FOR USING THE GH-3.8A SWINGING BUCKET ROTOR In Beckman Coulter Allegra 6 Series and Spinchron R and DLX Centrifuges This rotor has been manufactured in a registered

More information

F0850 Rotor. Used in Beckman Coulter Allegra 64R, Avanti 30, Allegra X-22 Series, Allegra 21 Series, Spinchron 15 Series, and GS-15 Series Centrifuges

F0850 Rotor. Used in Beckman Coulter Allegra 64R, Avanti 30, Allegra X-22 Series, Allegra 21 Series, Spinchron 15 Series, and GS-15 Series Centrifuges GS-TB-003J February 2008 F0850 Rotor Used in Beckman Coulter Allegra 64R, Avanti 30, Allegra X-22 Series, Allegra 21 Series, Spinchron 15 Series, and GS-15 Series Centrifuges 2008 Beckman Coulter, Inc.

More information

J-Lite JLA Fixed Angle Rotor

J-Lite JLA Fixed Angle Rotor J-TB-072G March 2005 J-Lite JLA-16.250 Fixed Angle Rotor Used In Beckman Coulter J2 and Avanti J Series Centrifuges 2005 Beckman Coulter, Inc. Printed in the U.S.A. ! SAFETY NOTICE This safety notice summarizes

More information

INSTRUCTION MANUAL. Model F14BCI-6x250y High Speed Rotor

INSTRUCTION MANUAL. Model F14BCI-6x250y High Speed Rotor FIBERLite CENTRIFUGE, Inc. Piramoon Technologies INSTRUCTION MANUAL Model F14BCI-6x250y High Speed Rotor For use only in Beckman Coulter Avanti J or HP centrifuges except the Avanti J-HC. Not for use in

More information

Instructions For Use. SW 28 and SW 28.1 Swinging-Bucket Rotors. For Use in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges

Instructions For Use. SW 28 and SW 28.1 Swinging-Bucket Rotors. For Use in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Instructions For Use SW 28 and SW 28.1 Swinging-Bucket Rotors For Use in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges L5-TB-069PA October 2011 Beckman Coulter, Inc. 250 S. Kraemer Blvd.

More information

Thermo Scientific Fiberlite Rotors. User Reference Manual

Thermo Scientific Fiberlite Rotors. User Reference Manual Thermo Scientific Fiberlite Rotors User Reference Manual Contents Page A. GENERAL INFORMATION 1. Safety Marks and Notices 1 2. Rotor Model Designations 5 3. Characteristics of Composite Materials 5 4.

More information

TLA-55 Rotor. Used in Beckman Coulter Optima MAX, MAX-E, TL, and TLX Series Tabletop Ultracentrifuges

TLA-55 Rotor. Used in Beckman Coulter Optima MAX, MAX-E, TL, and TLX Series Tabletop Ultracentrifuges TL-TB-020C November 2002 TLA-55 Rotor Used in Beckman Coulter Optima MAX, MAX-E, TL, and TLX Series Tabletop Ultracentrifuges 2002 Beckman Coulter, Inc. Published by the Centrifuge Instrument Systems Development

More information

JS-7.5 Swinging Bucket Rotor

JS-7.5 Swinging Bucket Rotor J-TB-007P January 2008 JS-7.5 Swinging Bucket Rotor Used In Beckman Coulter J2, J6, and Avanti J Series Centrifuges 2008 Beckman Coulter, Inc. Printed in the U.S.A. ! SAFETY NOTICE This safety notice summarizes

More information

JS-5.3 ROTOR. Used in Beckman Coulter Avanti J-20 and J-26 Series, and Avanti J-E Centrifuges. J-TB-089D November 2005

JS-5.3 ROTOR. Used in Beckman Coulter Avanti J-20 and J-26 Series, and Avanti J-E Centrifuges. J-TB-089D November 2005 H G F E D C B A 1 2 3 4 5 6 7 8 9 10 11 12 J-TB-089D November 2005 JS-5.3 ROTOR Used in Beckman Coulter Avanti J-20 and J-26 Series, and Avanti J-E Centrifuges 2005 Beckman Coulter, Inc. Printed in the

More information

An-50 Ti and An-60 Ti Analytical Rotor, Cells, and Counterbalance

An-50 Ti and An-60 Ti Analytical Rotor, Cells, and Counterbalance LXL/A-TB-003F June 2001 TM An-50 Ti and An-60 Ti Analytical Rotor, Cells, and Counterbalance For Use with the Beckman Coulter Optima XL-A and XL-I Analytical Ultracentrifuges 2001 Beckman Coulter, Inc.

More information

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge Instruction Manual Labnet Spectrafuge 16M Microcentrifuge Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com Safety Precautions NEVER

More information

TLS-55 Rotor. Used in Beckman Coulter Optima MAX, MAX-E, TL, and TLX Series Tabletop Ultracentrifuges

TLS-55 Rotor. Used in Beckman Coulter Optima MAX, MAX-E, TL, and TLX Series Tabletop Ultracentrifuges TL-TB-006J November 2001 TM TLS-55 Rotor Used in Beckman Coulter Optima MAX, MAX-E, TL, and TLX Series Tabletop Ultracentrifuges 2001 Beckman Coulter, Inc. PUBLISHED BY THE SPINCO BUSINESS CENTER OF BECKMAN

More information

Z100A Clinical Centrifuge

Z100A Clinical Centrifuge Z100A Clinical Centrifuge User Manual C0100-A Rev 2 August 2016 About This Manual This manual is designed to assist you in the optimal usage of your Labnet Z100A Clinical Centrifuge. The manual is available

More information

XCM12 Mini-Centrifuge

XCM12 Mini-Centrifuge Multi-speed Digital User Manual v. 1.0 C&A Scientific Disclaimer C & A Scientific owns the copyright of this user manual. No person shall reprint or distribute the contents of this user manual, including

More information

VTi 65.2 Rotor. Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges. L5-TB-089H December 2007

VTi 65.2 Rotor. Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges. L5-TB-089H December 2007 L5-TB-089H December 2007 Used In Beckman Coulter Class H, R, and S Preparative Ultracentrifuges 2007 Beckman Coulter, Inc. Printed in the U.S.A. ! SAFETY NOTICE This safety notice summarizes information

More information

STANDARD OPERATING PROCEDURES SOP: 1002 PAGE: 1 of 5 REV: 0.0 DATE: 12/23/96

STANDARD OPERATING PROCEDURES SOP: 1002 PAGE: 1 of 5 REV: 0.0 DATE: 12/23/96 PAGE: 1 of 5 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 INTERFERENCES AND POTENTIAL PROBLEMS 4.0 EQUIPMENT/APPARATUS 5.0 PROCEDURE 6.0 QUALITY ASSURANCE/QUALITY CONTROL 7.0 HEALTH AND SAFETY

More information

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment HIGH SPEED CENTRIFUGES Instruction Manual Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment Before Installation The centrifuge can be damaged if connected

More information

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection 1 PRODUCT DESCRIPTION 1.1 Usage in accordance with safety standards 1.1.1 General Information 1.1.1.1 Hazards and precautions 1.1.1.2 Brief description 1.1.1.3 Safety standards 1.1.1.4 Included items 1.1.1.5

More information

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge 1 INSTRUCTION MANUAL CAT. 72359-06 6-Place Table Top Centrifuge 2 CONTENTS IMPORTANT SAFETY GUIDELINES PLEASE READ BEFORE USE.. 3 SUPPLIED EQUIPMENT... 5 OPTIONAL ACCESSORIES... 5 SETUP... 5 UNPACKING...

More information

Tissue Master. User Manual

Tissue Master. User Manual Tissue Master User Manual This page left blank intentionally This manual is a guide for the use of the Omni International Tissue Master and accessories. Data herein has been verified and validated. It

More information

TL-TB-023D February MLS-50 Rotor. Used in Beckman Coulter Optima MAX, MAX-XP, and MAX-E Tabletop Ultracentrifuges Beckman Coulter, Inc.

TL-TB-023D February MLS-50 Rotor. Used in Beckman Coulter Optima MAX, MAX-XP, and MAX-E Tabletop Ultracentrifuges Beckman Coulter, Inc. TL-TB-023D February 2008 MLS-50 Rotor Used in Beckman Coulter Optima MAX, MAX-XP, and MAX-E Tabletop Ultracentrifuges 2008 Beckman Coulter, Inc. ! SAFETY NOTICE This safety notice summarizes information

More information

LR-IM-23 ROTORS AND TUBES. For Beckman Coulter Preparative Ultracentrifuges. User s Manual

LR-IM-23 ROTORS AND TUBES. For Beckman Coulter Preparative Ultracentrifuges. User s Manual LR-IM-23 ROTORS AND TUBES For Beckman Coulter Preparative Ultracentrifuges User s Manual ! SAFETY NOTICE This safety notice summarizes information basic to the safe operation of the rotors and accessories

More information

L5-TB-104B April NVT 65.2 Rotor. Used in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Beckman Coulter, Inc.

L5-TB-104B April NVT 65.2 Rotor. Used in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges Beckman Coulter, Inc. L5-TB-104B April 2008 NVT 65.2 Rotor Used in Beckman Coulter Class H, R, and S Preparative Ultracentrifuges 2008 Beckman Coulter, Inc. ! SAFETY NOTICE This safety notice summarizes information basic to

More information

Instruction Manual. Labnet Spectrafuge 7M Microcentrifuge

Instruction Manual. Labnet Spectrafuge 7M Microcentrifuge Instruction Manual Labnet Spectrafuge 7M Microcentrifuge Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com IMPORTANT NOTICE The use

More information

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE 82013-800 January 2006 INDEX PAGE 1. General Information... 2 1.1 Description... 2 1.2 Safety precautions to be observed before operating the centrifuge...

More information

Instructions For Use. Rotors and Tubes. For Beckman Coulter Preparative Ultracentrifuges. LR-IM-24AC February 2014

Instructions For Use. Rotors and Tubes. For Beckman Coulter Preparative Ultracentrifuges. LR-IM-24AC February 2014 Instructions For Use Rotors and Tubes For Beckman Coulter Preparative Ultracentrifuges February 2014 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A. Rotors and Tubes for Beckman Coulter

More information

TLA-110 Rotor. Used In Beckman Coulter Optima MAX-XP, MAX, MAX-E, TL, TLX, and TL-100 Tabletop Ultracentrifuges. TL-TB-019C September 2007

TLA-110 Rotor. Used In Beckman Coulter Optima MAX-XP, MAX, MAX-E, TL, TLX, and TL-100 Tabletop Ultracentrifuges. TL-TB-019C September 2007 TL-TB-019C September 2007 TLA-110 Rotor Used In Beckman Coulter Optima MAX-XP, MAX, MAX-E, TL, TLX, and TL-100 Tabletop Ultracentrifuges 2007 Beckman Coulter, Inc. Produced in the U.S.A. ! SAFETY NOTICE

More information

SPECTRAFUGE 6C. User Manual C0060 C V

SPECTRAFUGE 6C. User Manual C0060 C V SPECTRAFUGE 6C User Manual C0060 C0060-230V Lit M00031 Rev 2 August 2016 About This Manual This manual is designed to assist you in the optimal usage of your Labnet Spectrafuge 6C Centrifuge. The manual

More information

NVT 90 Rotor. Used In Beckman Class H, R, and S Preparative Ultracentrifuges. LXL-TB-006E December 2007

NVT 90 Rotor. Used In Beckman Class H, R, and S Preparative Ultracentrifuges. LXL-TB-006E December 2007 LXL-TB-006E December 2007 NVT 90 Rotor Used In Beckman Class H, R, and S Preparative Ultracentrifuges 2007 Beckman Coulter, Inc. Printed in the U.S.A. ! SAFETY NOTICE This safety notice summarizes information

More information

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd. Multi-Purpose, High Speed Centrifuge 1580R User s Manual Gyrozen Co., Ltd. B Station, 30-12 Gyeryong-ro 141-gil, Yuseoung-gu, Daejeon 305-301, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 www.gyrozen.com

More information

Clinispin CT20 User Manual

Clinispin CT20 User Manual Clinispin CT20 User Manual C0060-WOD-230EU Lit M00031 Rev 1 June, 2012 Safety Precautions NEVER NEVER NEVER NEVER NEVER NEVER NEVER NEVER ALWAYS ALWAYS ALWAYS ALWAYS use the centrifuge in any manner not

More information

Instructions For Use. Allegra X-14 Series. Centrifuges Rx Only in the U.S.A. PN B07493AD January 2018

Instructions For Use. Allegra X-14 Series. Centrifuges Rx Only in the U.S.A. PN B07493AD January 2018 Instructions For Use Allegra X-14 Series Centrifuges Rx Only in the U.S.A. January 2018 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A. Allegra X-14 Series Centrifuges for In-Vitro Diagnostics

More information

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd Benchtop Centrifuge GLO GT416 User s Manual Glotech Co., Ltd Contents 1. GLO GT416G Performance 2. Precautions 3. Technical Specifications 4. Installation 4 1. Delivery Checklist 4 2. Unpacking the Instrument

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1788-40 Copyright 2017 Terra Universal Inc. All rights reserved. Revised June 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

BlueSpin Cryo. (Cat. No. BSD-CRYO)

BlueSpin Cryo. (Cat. No. BSD-CRYO) BlueLine Instruments for Electrophoresis INSTRUCTION MANUAL BlueSpin Cryo (Cat. No. BSD-CRYO) SERVA Electrophoresis GmbH - Carl-Benz-Str. 7 - D-69115 Heidelberg Phone +49-6221-138400, Fax +49-6221-1384010

More information

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax: WARRANTY The Drucker Company warranties that this centrifuge is free from defects in materials and workmanship for 2 years. Should the centrifuge require warranty or out-of-warranty service please contact:

More information

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea INSTRUCTION MANUAL Ultra 5.0 Manufactured By In Korea 2 Ultra5.0 Instruction Manual Contents 1. Introduction 2. Note for Installation 3. Parts Description - Specifications - Caution - Safety Devices -

More information

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY 1250 LB. CAPACITY MECHANICAL WHEEL DOLLY 67287 SET-UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result

More information

Instructions For Use. Allegra X-30 Series Centrifuges. Rx Only. PN B05529AD November 2015

Instructions For Use. Allegra X-30 Series Centrifuges. Rx Only. PN B05529AD November 2015 Instructions For Use Allegra X-30 Series Centrifuges Rx Only PN B05529AD November 2015 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A. Allegra X-30 Series Centrifuges PN B05529AD (November

More information

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be read fully and understood PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material and

More information

Spectrafuge 24DMicrocentrifuge User Manual C2400 C V C V

Spectrafuge 24DMicrocentrifuge User Manual C2400 C V C V Spectrafuge 24DMicrocentrifuge User Manual C2400 C2400-100V C2400-230V Lit M00013 Rev 3 August 2016 About This Manual This manual is designed to assist you in the optimal usage of your Labnet 24D Microcentrifuge.

More information

Prism Microcentrifuge

Prism Microcentrifuge Prism Microcentrifuge User Manual C2400 C2400-100V C2400-230V C2500 C2500-100V C2500-230V Lit M00029 Rev 2 December 2012 Safety Precautions NEVER use the centrifuge in any manner not specified in these

More information

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge Compact Bench-Top Refrigerated Centrifuge 624R User s Manual Manufacturer: GYROZEN Co., Ltd. 30-12 Gyeryong-ro 141beon-gil, Yuseong-gu, Daejeon 34187, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 info@gyrozen.com

More information

USER MANUAL. D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC.

USER MANUAL. D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC. USER MANUAL D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC Before using centrifuge, please carefully read this user manual for efficient operation and safety. USER MANUAL Contents

More information

Instructions for Using the A-100/18 and A-100/30 Rotors

Instructions for Using the A-100/18 and A-100/30 Rotors AF-TB-009H October 2007 Instructions for Using the A-100/18 and A-100/30 Rotors In the Beckman Coulter Airfuge Ultracentrifuge 18 A-100/18 rmin rav rmax Axis of Rotation U.S. Pat. No. 3,997,104 SPECIFICATIONS

More information

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

1236R User s Manual. Multi-Purpose, High Speed Centrifuge Multi-Purpose, High Speed Centrifuge 1236R User s Manual Manufacturer: GYROZEN Co., Ltd. 30-12 Gyeryong-ro 141beon-gil, Yuseong-gu, Daejeon, 34187, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 info@gyrozen.com

More information

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # / ITEM #0506882 / 0506883 40 V LITHIUM-ION BATTERY MODEL #KB 240-06 / KB 440-06 Français p. 7 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date AB13786C 1 PRODUCT SPECIFICATIONS Battery

More information

Thermo Scientific. TCF-20 Rotor. for the Thermo Scientific Sorvall LYNX Centrifuge. Instruction Manual a 05 / 2013 Superspeed Centrifuge

Thermo Scientific. TCF-20 Rotor. for the Thermo Scientific Sorvall LYNX Centrifuge. Instruction Manual a 05 / 2013 Superspeed Centrifuge Thermo Scientific TCF-20 Rotor for the Thermo Scientific Sorvall LYNX Centrifuge Instruction Manual 50133975-a 05 / 2013 Superspeed Centrifuge Thermo Scientific TCF-20 Rotor for the Thermo Scientific

More information

High Speed Micro-Centrifuge User manual

High Speed Micro-Centrifuge User manual High Speed Micro-Centrifuge User manual 400.003.205 Centrifuge Supplied With Rotor 400.003.221 (24 x 1.5ml/2ml) 400.003.210 Refrigerated with Rotor 400.003.221 24x1.5ml/2ml 400.003.220 Rotor 5ml x 18 400.003.221

More information

DM1424 Hematocrit Centrifuge

DM1424 Hematocrit Centrifuge DM1424 Hematocrit Centrifuge SCILOGEX, LLC www.scilogex.com Before using centrifuge, please carefully read this user manual for efficient operation and safety. Contents Safety Reminder... 1 1. Specifications...

More information

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual Caution: This Nilfisk-CFM vacuum cleaner is not to be used in explosion hazardous areas as serious injury could result. Your new

More information

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges Thermo Scientific Heraeus Primo and Primo R Centrifuges Flexible and efficient, compact high-performance centrifuges Thermo Scientific Heraeus Primo and Primo R Centrifuges The compact high-performance

More information

Operating Manual. Multi Purpose Centrifuge Combi - 514R

Operating Manual. Multi Purpose Centrifuge Combi - 514R Operating Manual Multi Purpose Centrifuge Combi - 514R Multi Purpose Centrifuge Combi-514R Fig.1 1 2 3 4 5 1 Lid 2 Rotor 3 Control Panel 4 Display Panel 5 Emergency Lid Release 3 Contents 1 Introduction...

More information

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA OPERATING MANUAL Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA Mega17R OPERATING SPECIFICATION Mega 17R MAX RPM MAX RCF MAX CAPACITY SPEED DISPLAY 17,000

More information

D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited

D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited Before using centrifuge, please carefully read this user manual for its efficient operation and safety. USER

More information

ROTORS AND TUBES FOR Hitachi Preparative Micro Ultracentrifuge

ROTORS AND TUBES FOR Hitachi Preparative Micro Ultracentrifuge INSTRUCTION MANUAL Keep this rotor instruction manual and the centrifuge manual in the file. ROTORS AND TUBES FOR Hitachi Preparative Micro Ultracentrifuge This manual contains instruction for operation

More information

Instructions For Use. Avanti J-15 Series Centrifuges. Rx Only in the U.S.A. PN B80286AC March 2018

Instructions For Use. Avanti J-15 Series Centrifuges. Rx Only in the U.S.A. PN B80286AC March 2018 Instructions For Use Avanti J-15 Series Centrifuges Rx Only in the U.S.A. PN B80286AC March 2018 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A. Avanti J-15 Series Centrifuges for In Vitro

More information

OPERATION MANUAL MiniStirrus MAGNETIC STIRRER VP 706B-3. Speed Control Knob Power Switch

OPERATION MANUAL MiniStirrus MAGNETIC STIRRER VP 706B-3. Speed Control Knob Power Switch OPERATION MANUAL MiniStirrus MAGNETIC STIRRER VP 706B-3 TECHNICAL NOTE 212 Horizontal Stir Deck Vortex Stir Deck Speed Control Knob Power Switch Fig. 1 VP 706B-3 MiniStirrus Magnetic Stirrer shown with

More information

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 \ 8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 Marine Salt Testa Digital meter for the measurement of salinity, specific gravity and temperature Operation Manual 1. PRECAUTION The Marine Salt testa is for the sole

More information

N) manual. Register your instrument! Eppendorf Reference 2. Operating manual

N) manual. Register your instrument!  Eppendorf Reference 2. Operating manual erence ual 2 N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2016 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this

More information

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS LP-50DEF-BRL Lever Hand Pump System Barrel Mounting Owner s Manual 5252 East 36th Street North Wichita, KS USA 67220-3205 316-686-7361 FAX: 316-686-6746 800-835-0113 www.gpipumps.net

More information

Operation Manual Cole-Parmer MPR16 Multipurpose Refrigerated and MP16 Multipurpose Ambient Centrifuges Models , -25, -50, -55

Operation Manual Cole-Parmer MPR16 Multipurpose Refrigerated and MP16 Multipurpose Ambient Centrifuges Models , -25, -50, -55 Operation Manual Cole-Parmer MPR16 Multipurpose Refrigerated and MP16 Multipurpose Ambient Centrifuges Models 17406-20, -25, -50, -55 CE 1065z76_MAN_Rev.1 2016 Cole-Parmer Instrument Company, LLC Table

More information

D2012 & D2012 plus High Speed Mini Centrifuge

D2012 & D2012 plus High Speed Mini Centrifuge D2012 & D2012 plus High Speed Mini Centrifuge DLAB Laboratory Instruments Limited USER MANUAL Before using centrifuge, please carefully read this user manual for its efficient operation and safety. Contents

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

Instruction & Operation Manual

Instruction & Operation Manual Instruction & Operation Manual HSC Series Spring Check Valve Read and understand this manual prior to installing, operating or servicing this equipment This manual contains installation, operation, cleaning,

More information

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards

More information

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT User Manual Endoscope reprocessing the the way way it it should be be 1 Medi-Newt Neutralization System Instruction Manual 50096-951 Rev C 2011,

More information

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL Applies to FP100, FP120, and FP220 Models Qbiogene, Inc. (North America) 2251 Rutherford Road Carlsbad, CA 92008 Phone (800) 424-6101 Fax (760) 918-9313

More information

Operating Manual Cellspin

Operating Manual Cellspin Operating Manual Cellspin Clinical Centrifuge Date of Purchase Serial No. Place of purchase Copyright 2017 Hanil Scientific Inc. All rights reserved. Contact Us If you have and questions, contact Hanil

More information

Register your instrument! Eppendorf Reference 2. Operating manual

Register your instrument!  Eppendorf Reference 2. Operating manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Operating Eppendorf see on Fig. Tab. p. p. manual Reference 2 Copyright 2016 Eppendorf AG, Germany. All rights reserved, including

More information

Universal Centrifuge 320/320R

Universal Centrifuge 320/320R Pole Ideal Tajhiz Co. Operating Instructions Universal Centrifuge 3/3R www.medpit.com Cat No. 921 Contents 1 Use according to specification 2 Residual risks 3 Technical specifications 4 Notes on safety

More information

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun Model No. SP-33000 Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun - 1 - TABLE OF CONTENTS: 1. Description 2. Specification and Technical Data 3. Important Safety Instruction 4. Instructions for

More information

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P -322908-00000 Replaces Part No. P-191067-00000 Service Information WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable

More information

Instruction Manual for Compact Centrifuge Z 206 A

Instruction Manual for Compact Centrifuge Z 206 A Instruction Manual for Compact Centrifuge Z 206 A Page 1 of 24 INSTRUCTION MANUAL Z 206 A HERMLE Labortechnik GmbH CONTENTS 1 PRODUCT DESCRIPTION 1.1 Usage in accordance with safety standards 1.1.1 General

More information

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only. Concorde Liquid Handling Equipment Pipette Aid Operation Manual Cat. no. R14-PANAID *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version

More information

DM0636 Multi-purpose Centrifuge

DM0636 Multi-purpose Centrifuge DM0636 Multi-purpose Centrifuge Before using centrifuge, please carefully read this user manual for its efficient operation and safety. Contents Copyright:... 0 Safety Reminder... 1[ 1. Specifications...

More information

Mechanical Filter Pump Kit Up to 500 gallons

Mechanical Filter Pump Kit Up to 500 gallons Mechanical Filter Pump Kit Up to 500 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FM002P Questions, problems, missing parts? Before returning to your retailer, call our customer

More information