McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

Size: px
Start display at page:

Download "McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016"

Transcription

1 Replacement Parts List Revision Q 07/2016 McQuay Console Water Source Heat Pump WWAF,WWAG,WWAH,WWAS,WWAX,WWCQ WWDA,WWDB,WWDD,WWDE,WWDF,WWDG,WWDH, WWDJ,WWDN,WWDS,WWFQ,WWLA,WWLB,WWLC,WWLL, WWMA,WWMB,WWMC,WWMD,WWMF,WWMG,WWMH, WWMS,WWMT,WWMV,WWMX,WWMY,WWSQ Sizes 007, 009, 012, 015, 019 Design A (1) WWAA,WWAF,WWAG,WWAH,WWAS,WWAX, WWBL,WWBP,WWDA,WWDB,WWDC,WWDD,WWDE, WWDJ, WWDF, WWDG, WWDH, WWDL,WWDN,WWDS,WWDY, WWLA,WWLB,WWLC,WWLL,WWMA,WWMB,WWMC,WWMD, WWMF,WWMG,WWMH,WWMM,WWMN,WWMP,WWMQ, WWMS,WWMW,WWMX,WWMY,WWXB,WWXG Sizes 009, 012, 015, 019 Design B (2) To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History Nomenclature Serial...5 Model...6 Fan and Housing Assembly Unit Sizes 007, 009, 012 Design A (Code 3= 1)...7 Unit Sizes 009, 012 Design B (Code 3= 2)...8 Unit Sizes 015, 019 Designs A and B (Code 3= 1, 2)...9 Electric Heat...10 Refrigeration Circuit Diagrams Compressors and Compressor Components Unit Sizes 007, 009, Unit Sizes 015, Evaporator, Plugs, Valves, and Switches Design A (Code 3= 1)...14 Design B (Code 3= 2)...15 Condenser - Coil and Tubing Design A (Code 3= 1)...16 Design B (Code 3= 2)...17 Control Box MicroTech Control Diagram...18 Components...19 Mark IV Controller Diagram...20 Components...21 Cabinet Flat Top Cabinet Diagram...22 Unit Sizes 007, 009, Unit Sizes 015, Slope Top Cabinet Diagram...25 Unit Sizes 007, 009, Unit Sizes 015, Subbase Diagram...28 Components...29 Chassis Panels...30 Field Installed Accessories Critical Parts List Design A...CPL1 Design B... CPL2 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 2

3 Parts List Revision History Revision Date Description New 09/03 New A 03/05 Page 14 - Reversing Valve Solenoid Mark IV Controls with p/n was incorrect, it has been changed to Reversing Valve Solenoid DC Mark IV Controls p/n B 03/05 Page 33- High Sill Units table on bottom of page had incorrect heading. It changed from Unit Sizes 007, 009, 012 to 015,019. C 03/06 Page 7 - Deleted Honeywell information from Mark IV Unit Thermostats & Subbases and added Programmable with Remote Sensor Thermostat pn Page 18 - Mount-Motor pn was changed to Page 19 - Mount-Motor pn was changed to Capacitor-Motor 5MFD deleted under unit size 012, 265/60/1 voltage. Capacitor-Motor 3MFD deleted under unit size 012, 208/60/1and 230/60/1 voltages. Page 23 - Relay-Electric Heat p/n changed to Page 26 - Bubbles 420, 421&424 heater relay p/n changed from to Page 32 - Added 1 note to bubble 601 Front Panel. D 04/06 Page 35 - Bub 712 pn changed from to E 08/06 Removed references to 'contact SMG Parts Tech' and replaced with 'contact McQuay Parts'. F 10/08 Page 12, 13 - Ref 101 Removed vendor #s on all. Page 22 - Ref 375 pn was is now Page 25 - Ref 377 Added DC to pn Added Mark IV Board AC pn G 10/08 Page 14, 15 - Added note for reversing valves. Page 25 - Ref 377 Added note for pn and H 10/09 Page 15- add "until 3/05" to reversing valve p/n and solonoid p/n Add footnote ** Mark IV Controls. I 10/09 Page 15- Add reversing valve 3/05 &later p/n Add solonoid 3/05 & later p/n J 10/09 Page Add to reversing valve description "until 3/05" for p/n Add reversing valve "3/05 and later" pn Add to reversing valve solonoid description "until 3/05" for p/n Add reversing valve solonoid "3/05 and later" pn Add footnote change made 3/05 and later so the same component could be used for MicroTech and Mark IV units. K 01/10 Page Change reversing valve "3/05 and later" p/n to L 2/12 Title page- Add WWDJ to models. Page 5- Add WWDJ to Nomenclature Code 1 & 2. Pages Change rev. valve p/n to and p/n to Change rev. valve solenoid p/n to Pages 22, 23, 31, 32, 35- Add WWDJ to models. CPL1-2 Add Critical Parts List. M 7/13 Title Page- Add models- WWAA2,WWAF1,2,WWAG1,2,WWAH1,2,WWAS1,2,WWAX1,2, WWBL2,WWBP2,WWCQ1,WWDC2,WWDN1,2,WWDY2,WWFQ1,WWMT1,WWMV1,WWMW2, WWMX1,2,WWMY1,2,WWSQ1,WWXB2,WWXG2. Page 2- Contents, remove all model numbers update to page number changes. Page 4- Update Serial, February 199 & later to new format. Page 5- Code 1 & 2 -Add models(see above) and update all descriptions. Pages Add Refrigeration Circuit to main heading. Page 14- Change Rev. Valve p/n to , to , and to Add Solenoid Mark IV p/ns and Add Solenoid MT2000 p/ns , and Page Change title to MicroTech Control remove model numbers and consolidate pages. Page Change title to Mark IV Controller remove model numbers and consolidate pages. Page 25- Change titles. Page Change titles, delete models. Page 34 Consolidate all sizes to one page. CPL1-2 Change to CPL1 as Design A and CPL2 as Design B. N 2/15 Rebrand to Daikin. Title Page- Add models- WWDL 015 & WWMN 009, 012, 015. Page 5- Code 1 & 2 -Add models(see above) and update all descriptions. Page 14- Change footnote 5 from size 12 to size 15. CPL1-2 Rebrand CPL-master. O 3/15 Pages 22 & 24- Change Transformer to Delete 230/50V Transformer p/n Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 3

4 Parts List Revision History Revision Date Description P 05/16 Rebrand Daikin. Page 24- Add condensate overflow switch p/n Q 07/16 Numerous changes. Page 4- Add page for Parts List Revision History. Page 13- Add expansion valves part numbers to WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 4

5 Nomenclature Serial Until February, A Plant Identification 7 = Auburn Year Manufactured 9 = 1999 A = January B = February C = March D = April E = May F = June Engineering Revision Serial Month Manufactured G = July I = August J = September K = October L = November M = December Serial February, 1999 & later AUB U Plant Identification Abbreviation AUB = Auburn Serial (build sequence) U= Unit Week of Manufacture Year of Manufacture 00= = = 2002 etc. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 5

6 Nomenclature Model WWLA E Z 00 U 11 AA 14 A I Code: 1 & & 2. Product Category & Product Identifier WWAA- WSHP-Flat Top Wall Mt, Alerton, Lo-Sil WWAF- WSHP-Flat Top Wall Mt, Alerton, Hi-Sil WWAG- WSHP-Slope Top Wall Mt, Alerton, Hi-Sil, Geothermal WWAH- WSHP-Slope Top Wall Mt, DDC Less Board, Hi-Sil, Geothemal WWAS- WSHP-Slope Top Wall Mt, Alerton, Hi-Sil WWAX- WSHP-Flat Top Wall Mt, Alerton, Hi-Sil, Geothermal WWBL- WSHP-Console, Lo-Sil WWBP- WSHP-Console, Geothermal WWCQ- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, Chassis, Extra Quiet WWDA- WSHP-Flat Top Wall Mt, DDC, Lo-Sil, 60HZ WWDB- WSHP-Slope Top Wall Mt, DDC, Lo-Sil, 60HZ WWDC- WSHP-Flat Top Wall Mt, DDC, Hi-Sil, Chassis WWDD- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, 60HZ WWDE- WSHP-Slope Top Wall Mt, DDC, Lo-Sil, 60HZ WWDF- WSHP-Flat Top Wall Mt, DDC, Hi-Sil, 60HZ WWDG- WSHP-Flat Top Wall Mt, DDC, Hi-Sil, 60HZ WWDH- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, 60HZ WWDJ- WSHP-Slope Top Wall Mt, DDC Less Board, Lo-Sil, 60HZ WWDL- WSHP-Flat Top Wall Mt, DDC Less Board, Hi-Sil WWDN- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, Chassis, Geothermal WWDS- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, 60HZ WWDY- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, Geothermal WWFQ- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, Extra Quiet WWLA- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil, 60HZ WWLB- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWLC- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWLL- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, 60HZ WWMA- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWMB- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWMC- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, 60HZ WWMD- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWMF- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil WWMG- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil WWMH- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil WWMN- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil, Chassis, Geothermal WWMS- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil WWMT- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, Chassis, Europe WWMV- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, Chassis, Europe WWMW- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, Geothermal WWMX- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, Geothermal WWMY- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil, Geothermal WWSQ- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, Extra Quiet WWXB- WSHP-Slope Top Wall Mt, Alerton, Lo-Sil, R-410A WWXG- WSHP-Flat Top Wall Mt, DDC Less Board, Hi-Sil, R-410A 3. Design (Vintage) 1= Design A 2= Design B (009, 012, 015, 019 only) 4. Size (1000's BTUH) 007, 009, 012, 015, Unit Voltage A= 115/60/1 E= 208/230/60/1 J= 265/277/60/1 M= 230/50/1 6. Coil Options Z= None 7. Heating Options 00= None 20= 1.0 KW Electric Heat (sizes 007, 009, 012) 30= 2.0 KW Electric Heat (sizes 015, 019) 8. Hand Orientation V= Left Hand Piping Connection U= Right Hand Piping Connection 9. Controls 11= Unit Mounted ACO 12= Unit Mounted MCO 13= 24V Wall Thermostat 14= MT Tennant Set Point w/override 10. Discharge AA= Top Discharge 11. Return Air/ O.A. 14= Bottom 12. Power Connection A= Junction Box 13. Color I= Antique Ivory 14. SKU 15. Product Style 1= 1st Style Change WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 6

7 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 Fan and Housing Assembly Unit Sizes 007, 009, 012 Design A (Code 3= 1) Ref Description Specification Part N/S Motor, 1/60 HP 115/60/ Motor, 1/60 HP 208/230/60/ Motor, 1/60 HP 265/60/ Motor, 1/60 HP 230/50/ Motor, 1/24 HP 115/60/ Motor, 1/24 HP 208/230/60/ Motor, 1/24 HP 265/60/ Motor, 1/40 HP 230/50/ N/S Capacitor, 4MFD 370V until 6/ Capacitor, 4MFD 370V 6/09 & later Capacitor, 2MFD 370V Capacitor, 5MFD 370V until 6/ Capacitor, 5MFD 370V 6/09 & later Capacitor, 3MFD 370V until 3/ Capacitor, 3MFD 370V 3/09 & later N/S Plug- Motor 2 Ckt. Plug Plug- Motor 6 Ckt. Housing N/S Fan Scroll N/S Support- Fan Housing N/S Mount- Motor N/S Clip- Motor Mount N/S Inlet Ring Inlet Ring N/S Fan Wheel N/S Bracket- Capacitor Boot- Capacitor Protector- Capacitor N/S Plate- Motor Heat Resistor N/S Resistor- Motor 100 Watt Resistor- Motor 100 Watt/ 300 OHM N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 7

8 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 Fan and Housing Assembly Unit Sizes 009, 012 Design B (Code 3= 2) Ref Description Specification Part N/S Motor, 1/24 HP 115/60/ Motor, 1/24 HP 208/230/60/ Motor, 1/24 HP 265/60/ Motor, 1/60 HP 230/50/ Motor, 1/15 HP 115/60/ Motor, 1/15 HP 208/230/60/ Motor, 1/15 HP 265/60/ Motor, 1/40 HP 230/50/ N/S Capacitor, 5MFD 370V until 6/ Capacitor, 5MFD 370V 6/09 & later Capacitor, 2MFD 370V Capacitor, 3MFD 370V until 3/ Capacitor, 3MFD 370V 309 & later N/S Plug- Motor 6 Ckt. Housing N/S Fan Scroll N/S Support- Fan Housing N/S Mount- Motor N/S Clip- Motor Mount N/S Inlet Ring Inlet Ring N/S Fan Wheel N/S Bracket- Capacitor Boot- Capacitor Protector- Capacitor N/S Plate- Motor Heat Resistor N/S Resistor- Motor 100 Watt Resistor- Motor 100 Watt/ 300 OHM N/S= Not shown on diagram. 6 Until 11/ /02 and later. 8 Until 2/ /02 and later WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 8

9 208/60/1 230/60/1 265/60/1 230/50/1 208/60/1 230/60/1 265/60/1 230/50/1 Fan and Housing Assembly Unit Sizes 015, 019 Designs A and B (Code 3= 1, 2) Ref Description Part N/S Motor, 1/8 HP Motor, 1/8 HP Motor, 1/8 HP N/S Capacitor, 4MFD 370V until 6/ Capacitor, 4MFD 370V 6/09 & later Capacitor, 3MFD 370V until 6/ Capacitor, 3MFD 370V 6/09 & later N/S Plug- Motor 2 Ckt. Plug Plug- Motor 6 Ckt. Plug Housing N/S Fan Housing Assembly Housing- Discharge Housing- Access Hub Clamp N/S Support- Motor N/S Bracket- Capacitor N/S Clip- Motor Mount N/S Capacitor Boot 1.5" Diameter N/S= Not shown on diagram. 11 Includes housings, clamp, wheel, etc. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 9

10 Electric Heat To Control Box Single Element- All Voltages Ref. Description Part Heater 1.0 KW/ 265V 13 Code 7= KW/ 265V 13 Code 7= Limit Switch 1.0 KW Heater Code 7= KW Heater Code 7= Screw until 5/ Screw 5/02 & later 4SBA Heater Voltage. NOTE: Electric Heat is not available on 115V units. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 10

11 Refrigeration Circuit Diagrams Control Box WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 11

12 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 Refrigeration Circuit Compressors and Compressor Components Unit Sizes 007, 009, Ref Description Part 101 Compr, 6670 BTUH Compr, 6625 BTUH Compr, 6625 BTUH Compr, 9200 BTUH Compr, 9100 BTUH Compr, 9100 BTUH Compr, BTUH Compr, BTUH Compr, BTUH Capacitor, 35MFD 370V until 4/ Capacitor, 35MFD 440V 4/12 & later Capacitor, 15MFD 370V Capacitor, 15MFD 440V until 4/ Capacitor, 15MFD 440V 4/12 & later Capacitor, 20MFD 370V Capacitor, 25MFD 370V until 3/ Capacitor, 25MFD 370V 3/09 & later Capacitor, 25MFD 440V Bracket- Capacitor Locknut- Mounting until 12/ Locknut- Mounting 12/01 & later Overload- Compressor 115/60/ /230/60/ /60/1 & 230/50/ Mounting Sleeve until 5/ Mounting Sleeve 5/00 & later N/S Grommet- Compressor N/S Capacitor- Boot Capacitor- Boot N/S Gasket- Compressor N/S Gasket- Compressor N/S Nut- Compressor N/S Spring- Compressor N/S Terminal Cover- Compressor N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 12

13 208/60/1 230/60/1 265/60/1 230/50/1 208/60/1 230/60/1 265/60/1 230/50/1 Refrigeration Circuit Compressors and Compressor Components Unit Sizes 015, Ref Description Part 101 Compr, BTUH Compr, BTUH Compr, BTUH Compr, BTUH Capacitor, 25MFD 370V until 3/ Capacitor, 25MFD 370V 3/09 & later Capacitor, 25MFD 440V Bracket- Capacitor N/S Capacitor, Boot Locknut- Mounting Mounting Sleeve N/S Grommet- Compressor N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 13

14 Refrigeration Circuit Evaporator, Plugs, Valves, and Switches Design A (Code 3= 1) Ref. Description Part N/S Evaporator Coil until 2/ Evaporator Coil 2/03 & later Evaporator Coil Evaporator Coil Evaporator Coil Evaporator Coil N/S Strap- Evap. Coil L.H. Units (C08= V) only N/S Extension- Evap. Header Plate N/S Drain Pan- Evaporator Drain Pan- Evaporator Drain Pan- Evaporator N/S Reversing Valve * until 3/ Reversing Valve * 3/05 and later Reversing Valve * until 3/ Reversing Valve * 3/05 and later Reversing Valve * until 3/ Reversing Valve * 3/05 and later N/S Solenoid, Reversing Valve * Mark IV Units until 3/ Mark IV Units until 3/ Mark IV Units 3/05 to 3/ Mark IV Units 3/11 & later MicroTech 2000 Units until 3/ MicroTech 2000 Units until 3/ MicroTech 2000 Units 3/05 to 3/ MicroTech 2000 Units 3/11 & later N/S Strainer Strainer Strainer N/S Capillary Capillary Capillary Capillary Capillary N/S Freezestat w/bulb N/S Fusible Plug N/S High Pressure Switch until 11/ High Pressure Switch 11/00 & later N/S Refrigerant Valve Assembly until 1/ Refrigerant Valve Assembly 1/03 & later N/S Muffler N/S Discharge Line Weight Discharge Line Weight Discharge Line Weight Clip 50 Hz. (C05= M) N/S Absorber- Vibration 50 Hz. (C05= M) 4FDX Absorber- Vibration 50 Hz. (C05= M) 4FDX Size /50/1 (code 5= M) units use capillary * The new & old valves/solenoids are not compatible. If a new valve is ordered to replace an old style valve, a new solenoid coil must also be ordered. Refer to Ranco Reversing Valve Form WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 14

15 Refrigeration Circuit Evaporator, Plugs, Valves, and Switches Design B (Code 3= 2) Ref. Description Part N/S Evaporator Coil 60 Hz. Units (C05= A, E, J) Evaporator Coil 50 Hz. Units (C05= M) Evaporator Coil 60 Hz. Units (C05= A, E, J) Evaporator Coil 50 Hz. Units (C05= M) Evaporator Coil Evaporator Coil N/S Strap- Evap. Coil L.H. Units (C08= V) only N/S Extension- Evap. Header Plate N/S Drain Pan- Evaporator N/S Drain Pan- Evaporator N/S Reversing Valve * until 3/ Reversing Valve * 3/05 & later Reversing Valve * until 3/ Reversing Valve * 3/05 & later Reversing Valve * until 3/ Reversing Valve * 3/05 & later N/S Solenoid, Reversing Valve * Mark IV Units until 3/ Mark IV Units until 3/ Mark IV Units 3/05 to 3/ Mark IV Units 3/11 & later MicroTech 2000 Units until 3/ MicroTech 2000 Units until 3/ All Units 3/05 to 3/ All Units 3/11 & later N/S Strainer Strainer Strainer N/S Capillary Capillary Capillary Capillary N/S Freezestat w/bulb N/S Fusible Plug N/S High Pressure Switch N/S Refrigerant Valve Assembly until 1/ Refrigerant Valve Assembly 1/03 & later N/S Muffler N/S Discharge Line Weight Discharge Line Weight Discharge Line Weight Clip 50 Hz. (C05= M) N/S Absorber- Vibration 50 Hz. (C05= M) 4FDX Absorber- Vibration 50 Hz. (C05= M) 4FDX N/S Expansion Valve Expansion Valve Expansion Valve Expansion Valve Size /50/1 (code 5= M) units use capillary * The new & old valves/solenoids are not compatible. If a new valve is ordered to replace an old style valve, a new solenoid coil must also be ordered. Refer to Ranco Reversing Valve Form WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 15

16 Refrigeration Circuit Condenser- Coil and Tubing Design A (Code 3= 1) Left-hand Configuration Right-hand Configuration Ref. Description Specification Part Condenser Copper Inner Tube Condenser Copper Inner Tube Condenser Copper Inner Tube Condenser Copper Inner Tube Tube- Inlet: LH Unit C06= L Tube- Inlet: LH Unit C06= L Tube- Inlet: RH Unit C06= R Tube- Inlet: RH Unit C06= R Tube- Outlet: LH Unit C06= L Tube- Outlet: RH Unit C06= L Tube- Outlet: LH Unit C06= R Tube- Outlet: RH Unit C06= R Tube Coupling Tube- Condenser to Strainer Tube- Condenser to Strainer Tube- Condenser to Strainer WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 16

17 Refrigeration Circuit Condenser- Coil and Tubing Design B (Code 3= 2) Left-hand Configuration Right-hand Configuration Ref. Description Specification Part Condenser Copper Inner Tube Condenser Copper Inner Tube Condenser Copper Inner Tube Condenser Copper Inner Tube Condenser Copper Inner Tube Tube- Inlet: LH Unit C06= L Tube- Inlet: LH Unit C06= L Tube- Inlet: LH Unit C06= L Tube- Inlet: RH Unit C06= R Tube- Inlet: RH Unit C06= R Tube- Inlet: RH Unit C06= R Tube- Outlet: LH Unit C06= L Tube- Outlet: RH Unit C06= L Tube- Outlet: RH Unit C06= L Tube- Outlet: LH Unit C06= R Tube- Outlet: RH Unit C06= R Tube- Outlet: RH Unit C06= R Tube Coupling Tube- Condenser to Strainer Tube- Condenser to Strainer Tube- Condenser to Strainer WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 17

18 Control Box MicroTech Control Diagram Transformer Detail WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 18

19 Control Box MicroTech Control Components Ref. Description Part Voltage 208/60 230/60 265/60 230/ Transformer until 3/ Transformer 3/01 & later Transformer until 3/ Transformer 3/01 & later Terminal- Quick Connect Top Panel Flat Top Units Top Panel Slope Top Units End Panel- Flat Top End Panel- Slope Top Snap in Bushing Terminal Board Potentiometer Rocker Switch Knob PC Board Main Controller MicroTech 2000 until 4/ MicroTech /09 to 2/ MicroTech /11 to 9/ MicroTech /12 & later Switch- 2 Button Overlay- Control Plate Code 9= Code 9= Switch- Momentary N.O Control Box Bottom Split Bushing Terminal Block 4 Terminals Resistor OHM Relay- Fan 24V N/S Terminal Block Lo Volt N/S Terminal Block ELUPC N/S Relay- Electric Heat 2PDT N/S Air Sensor until 2/ Air Sensor (DAT & RAT) 2/00 & later N/S Water Sensor until 2/ Water Sensor (EWT & LWT) 2/00 & later N/S Junction Box Connection Junction Box Junction Box Junction Box Cover Junction Box Cover Terminal Block Medium Duty End Block N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 19

20 Control Box Mark IV Controller Diagram Ref# 387 Overlay Detail WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 20

21 Control Box Mark IV Controller Components Ref. Description Part Voltage 115/60 208/60 230/60 265/60 230/ Transformer until 3/ Transformer 3/01 and later Transformer until 3/ Transformer 3/01 and later Transformer until 3/ Transformer 3/01 and later Top Panel- Flat Top Top Panel- Slope Top Plate- Thermostat End Panel- Flat Top End Panel- Slope Top Snap In Bushing Terminal Board Temp. Control straps on tube Auto Changeover Units C09= Manual Changeover Units C09= Rocker Switch Knob PC Board Main Controller Mark IV DC ** Mark IV AC ** Stand Off 7/17" Switch- 2 Button C09= 11 or Switch- 4 Button C09= Overlay- Control Plate Code 9= Overlay- Control Plate Code 9= Overlay- Control Plate Code 9= Low Temp. Control C09= Screw Switch, Momentary C09= Junction Box Junction Box Junction Box Cover Junction Box Cover Snap In Bushing Cup Washer 4WEA Heater Relay 24V 2PDT Heater Relay 24V 2PDT Bracket- Night Setback Code 9= Heater Relay 24V 1PDT Receptacle 15 Circuits Bottom Panel Rocker Switch SPDT Terminal Block Bushing N/S Low Temperature- Electric Heat SPDT N/S Condensate Overflow Switch NOTE: Code 9= 11 applies to all WWL* units. Code 9= 12 (unit mtd.) and Code 9= 13 (remote) apply to WWM* units. ** When replacing reversing valve and/or coil refer to Service Bulletin WS-SB N/S= Not Shown on Diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 21

22 Cabinet Flat Top Diagram Door oriented for left hand piping unit. Door oriented for right hand piping unit WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 22

23 Cabinet Flat Top Unit Sizes 007, 009, 012 Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille Door Frame Door Blockoff (LH Unit Only Code 8= V) N/S Gasket N/S Insulation- Felt N/S= Not Shown on Diagram. Low Sill Units High Sill Units Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille Door Frame Door Blockoff (LH Unit Only Code 8= V) N/S Gasket N/S Insulation- Felt N/S= Not Shown on Diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 23

24 Cabinet Flat Top Unit Sizes 015, 019 Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille Door Frame Door Blockoff (LH Unit Only Code 8= V) N/S Gasket N/S Insulation- Felt N/S= Not Shown on Diagram. Low Sill Units Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille Door Frame Door Blockoff (LH Unit Only Code 8= V) N/S Gasket N/S Insulation- Felt N/S= Not Shown on Diagram. High Sill Units WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 24

25 Cabinet Slope Top Diagram Door oriented for left hand piping unit. 651 Door oriented for right hand piping unit WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 25

26 Cabinet Slope Top Unit Sizes 007, 009, 012 Low Sill Units Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille until 11/ Grille 11/99 & later Door Frame until 11/ Door Frame 11/99 & later Door until 11/ Door 11/99 & later End Cap until 11/ End Cap 11/99 & later Blockoff- L.H. Units only (C06= L) Front Panel with corrosion Resistant Antique Ivory Paint, p/n High Sill Units Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille until 11/ Grille 11/99 & later Door Frame until 11/ Door Frame 11/99 & later Door until 11/ Door 11/99 & later End Cap until 11/ End Cap 11/99 & later Blockoff- L.H. Units only (C06= L) WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 26

27 Cabinet Slope Top Unit Sizes 015, 019 Low Sill Units Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille until 11/ Grille 11/99 & later Door Frame until 11/ Door Frame 11/99 & later Door until 11/ Door 11/99 & later End Cap until 11/ End Cap 11/99 & later Blockoff- L.H. Units only (C06= L) High Sill Units Ref. Description Part Qty. 601 Front Panel Left End Panel Right End Panel Tie Piece Grille until 11/ Grille 11/99 & later Door Frame until 11/ Door Frame 11/99 & later Door until 11/ Door 11/99 & later End Cap until 11/ End Cap 11/99 & later Blockoff- L.H. Units only (C06= L) WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 27

28 Subbase Diagram 605 Subbase frame shown in left hand piping position. 711 Subbase frame shown in right hand piping position. 712 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 28

29 Subbase, Back Panel Components Unit Sizes- 007, 009, 012 High Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either Subbase Frame 115/208/230/265/60 Either Subbase Frame 230/50 Either Subbase Panel 115/208/230/265/60 Either Subbase Panel 230/50 LH Subbase Panel 230/50 RH N/S Throwaway Filter All Either Unit Sizes- 007, 009, 012 Low Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either Subbase Frame 115/208/230/265/60 LH Subbase Frame 115/208/230/265/60 RH Subbase Frame 230/50 LH Subbase Frame 230/50 RH N/S Throwaway Filter All Either Unit Sizes- 015, 019 High Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either Subbase Frame 208/230/265/60 Either Subbase Frame 230/50 Either Subbase Panel 208/230/265/60 Either Subbase Panel 230/50 LH Subbase Panel 230/50 RH N/S Throwaway Filter All Either N/S= Not Shown on Diagram. Unit Sizes- 015, 019 Low Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either Subbase Frame 208/230/265/60 LH Subbase Frame 208/230/265/60 RH Subbase Frame 230/50 LH Subbase Frame 230/50 RH N/S Throwaway Filter All Either WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 29

30 Chassis Panels Components Ref. Description Part Qty. N/S Basepan Unit Sizes 007, 009, Unit Sizes 015, N/S Left Panel Flat Top Units Left Panel Slope Top Units N/S Right Panel N/S Center Panel Flat Top Center Panel Slope Top N/S Coil Mount Unit Sizes 007, 009, Unit Sizes 015, N/S Control Access Flat Top Control Access Slope Top N/S Fan Cover Panel Unit Sizes 007, 009, 012 Flat Top/ High Sill Unit Sizes 015, 019 Flat Top/ High Sill Unit Sizes 007, 009, 012 Slope Top/High Sill Unit Sizes 015, 019 Slope Top/High Sill Unit Sizes 007, 009, 012 Flat Top/Low Sill Unit Sizes 015, 019 Flat Top/Low Sill Unit Sizes 007, 009, 012 Slope Top/ Low Sill Unit Sizes 015, 019 Slope Top/ Low Sill N/S Water Tube Retainer Clip N/S Filter Support Low Sill units only N/S Gasket- 1/8" X 3/8" X 156" Low Sill units only N/S Back Panel Assembly 14 Unit Sizes 007, 009, /50/ Unit Sizes 015, /50/ Unit Sizes 007, 009, /208/230/265/60/ Unit Sizes 015, /208/230/265/60/ N/S= Not Shown on Diagram. 14 Includes condenser access and evaporator baffle. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 30

31 Field Installed Accessories Fuse & Disconnect with Cordset Ref. Description Specification Part 208/ 265V 230V Kit Kit Disconnect Box Bracket Cover Panel Fuse Holder Fuse 15A Receptacle N/A 702 Switch N/S Cord Set Cord Set N/S= Not Shown on Diagram. N/A= Not Applicable. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 31

32 208/60/1 230/60/1 265/60/1 Field Installed Accessories Continued 808 Manual Outside Air Damper 803 Ref. Description Part Qty. Kit Damper Box Actuator Damper Door N/S Gasketing N/S Gasketing N/S= Not Shown on Diagram. 805 Motorized Outside Air Damper Ref. Description Specification Part 208V Kit V Kit V Kit Damper Box Wire Box Damper Door Damper Motor 115V Units Damper Motor 208V Units Damper Motor 230V Units Operating Arm Spring- Extension Toggle Switch Door Link N/S Gasketing N/S Gasketing N/S= Not Shown on Diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 32

33 Field Installed Accessories Continued Subbase Kits- Chassis Only High Sill Units WWDD, WWMC, & WWMG Units Description Right Hand Left Hand Sizes 007, 009, Sizes 015, Duct Collar Kit- Chassis Only Units WWDD, WWDE, WWMC, WWMD, WWMG, WWMH Description 007, 009, , 019 Duct Collar Kit Duct Collar Only Gasket Cabinet/Subbase/Backwrap Replacement Kits 4 Description Unit Sizes Top Sill Piping Hand Part Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat Low Right Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat Low Left Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat High Right Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat High Left Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope Low Right Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope Low Left Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope High Right Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope High Left Cabinet/Subbase/Backwrap Kit 015, 019 Flat Low Right Cabinet/Subbase/Backwrap Kit 015, 019 Flat Low Left Cabinet/Subbase/Backwrap Kit 015, 019 Flat High Right Cabinet/Subbase/Backwrap Kit 015, 019 Flat High Left Cabinet/Subbase/Backwrap Kit 015, 019 Slope Low Right Cabinet/Subbase/Backwrap Kit 015, 019 Slope Low Left Cabinet/Subbase/Backwrap Kit 015, 019 Slope High Right Cabinet/Subbase/Backwrap Kit 015, 019 Slope High Left Individual components are listed in the Cabinet and Subbase Sections in the RPL. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 33

34 Continued Relays Description Part Auxiliary Relay V, Normally Open. Used with WCDL & WCDS Units. Dry Contact Relay 5 VDC in; AC/DC out, Normally Open, SPST. Replaces the standard 24V relays in the MicroTech panel. Used with WCDL & WCDS Units. Motorized Valve Control Relay Kit Used on WCMS units with Motorized Valve. Kit contains circuit board p/n and 6-pin plug p/n Pump Restart Relay Used on Mark IV units (WCMS) in conjunction w/ LWC to restart when compressor starts. One relay required per 200 units along a 2-wire daisy chain. Time Schedule Relay. 24 VDC relay controls the Mark IV (WCMS) "U" terminal. One required per time clock output. Replaces 24 VAC relay. Ball Valves and Motorized Valves Description Part Combination Shutoff/Balancing Valve with Memory Stop (2 per unit) Motorized Valve Kit Includes valve/operator, conduit assy. Valve shuts water flow off. 300 PSIG max. 1 Requires Motorized Valve control relay (see relays above). Field Installed Accessories Hoses Description Specification Part Fire- Rated Rubber Supply/Return Hoses. Steel Braided 9" long, 1/2" I.D hose with one MPT and one MPT swivel fitting. 2 per unit. 12" long, 1/2" I.D " long, 1/2" I.D Filters Description Unit Size Specification Part Throwaway Filter High Sill Low Sill , 019 High Sill , 019 Low Sill Immersion Sensor, Thermostat Guard Description Part Immersion Sensor Thermostat Guard Honeywell TG12A Clear plastic guard with ring base, lock and key. Elbow Kit Description Specification Part Added to the End of Supply & Return Piping ½" X ½" WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 34

35 MicroTech Wall- Mounted Room Sensors Description Part Sensor w/ LED, Tenant Override Sensor w/ LED, Tenant Override, Tenant Setpoint Sensor w/ LED, Tenant Override, Thermostat Sensor w/ LED, Tenant Override, Tenant Setpoint, Thermostat Description Specification Part Master/Slave Control Board Master & 1 Slave Auxiliary Relay 24 VDC Description Specification Part Heat Pump Loop Installation Kit Controls Main Water Loop Temp. Includes Flow Switch p/n , Immersion Sensor , O.A. Sensor p/n Open Lower Loop Installation Kit Controls Main Water Loop Temp. Includes Flow Switch p/n , Immersion Sensor Loop Water Control Panel 2 LWC16 w/modem Provides 9 (LWC16) or 17 (LWC24) outputs for heat rejection and heat LWC16 no modem addition stages and time clock (6 max.) schedules. LWC24 w/modem LWC24 no modem Remote Alarm Panel 3 Monitors LWC Panel Status See RPL for complete LWC panel parts list. 3 Panel components listed below. Mark IV Unit Control Accessories Mark IV Unit Thermostats and Subbases Description Part Thermostat Standard MCO Subbase- Standard MCO Thermostat and Subbase- Deluxe ACO w/ NSB & OR Thermostat and Wallplate- Electronic, Non-Programmable Thermostat and Wallplate- Electronic, Programmable Thermostat,Programmable with Remote Sensor Field Installed Accessories Continued Heat Pump Loop Installation Kits and Control Panels Remote Alarm Panel Detail (RAP) Ref. Description Part Qty. 300 Electrical Box Switch- Silence LED- Red Horn- Alarm LED- Yellow WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes A/ B Rev. Q 07/16 RPL / Page 35

36 Critical Daikin Applied OEM Parts Are What Your Daikin Applied HVAC Unit Needs! Console WSHP WWA*,WWC*,WWD*,WWF*,WWL*, WWM*, WWS* Sizes Design A (1) CRITICAL PART COMPONENTS MODEL UNIT SIZE VOLTAGE NUMBER CONTROLS Mark IV DC ALL ALL N/A Mark IV AC ALL ALL N/A MicroTech 2000 WWD*, WWX* ALL N/A Alerton WWA* ALL N/A COMPRESSOR Compr, 6670 BTU ALL /60/ Compr, 6625 BTU ALL /230/60/ Compr, 6625 BTU ALL /60/1 & 230/50/ Compr, 9200 BTU ALL /60/ Compr, 9100 BTU ALL /230/60/ Compr, 9100 BTU ALL /60/1 & 230/50/ Compr, BTU ALL /60/ Compr, BTU ALL /230/60/ Compr, BTU ALL /60/1 & 230/50/ Compr, BTU ALL /230/60/ Compr, BTU ALL /60/1 & 230/50/ Compr, BTU ALL /230/60/ Compr, BTU ALL /60/1 & 230/50/ BLOWER MOTOR Motor, 1/60 HP ALL 007, /60/ Motor, 1/60 HP ALL 007, /60/ Motor, 1/60 HP ALL 007, /60/ Motor, 1/60 HP ALL 007, /50/ Motor, 1/24 HP ALL /60/ Motor, 1/24 HP ALL /60/ Motor, 1/24 HP ALL /60/ Motor, 1/8 HP ALL /50/ Motor, 1/8 HP ALL 015, /60/ Motor, 1/8 HP ALL 015, /60/ Motor, 1/8 HP ALL 015, /50/ FAN HOUSING & WHEEL Fan Wheel ALL N/A Fan Housing Assembly ALL 015, 019 N/A REFRIGERATION CIRCUIT Reversing Valve ALL N/A Reversing Valve ALL 012 N/A Reversing Valve ALL 015, 019 N/A Solenoid-Reversing Valve ALL ALL N/A Solenoid-Reversing Valve ALL ALL N/A SENSOR Air Temp Sensor (DAT & RAT) ALL ALL N/A Water Temp Sensor (LWT & EWT) ALL ALL N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. Q 07/2016 CPL Page 1 of 2

37 Critical Daikin Applied OEM Parts Are What Your Daikin Applied HVAC Unit Needs! Console WSHP WWA*,WWB*,WWD*,WWL*, WWM*, WWX* Sizes Design B (2) CRITICAL PART COMPONENTS MODEL UNIT SIZE VOLTAGE NUMBER CONTROLS Mark IV DC ALL ALL N/A Mark IV AC ALL ALL N/A MicroTech 2000 WWD*, WWX* ALL N/A Alerton WWA* ALL N/A COMPRESSOR Compr, 9200 BTU ALL /60/ Compr, 9100 BTU ALL /230/60/ Compr, 9100 BTU ALL /60/1 & 230/50/ Compr, BTU ALL /60/ Compr, BTU ALL /230/60/ Compr, BTU ALL /60/1 & 230/50/ Compr, BTU ALL /230/60/ Compr, BTU ALL /60/1 & 230/50/ Compr, BTU ALL /230/60/ Compr, BTU ALL /60/1 & 230/50/ BLOWER MOTOR Motor, 1/24 HP ALL /60/ Motor, 1/24 HP ALL /60/ Motor, 1/24 HP ALL /60/ Motor, 1/60 HP ALL /50/ Motor, 1/15 HP ALL /60/ Motor, 1/15 HP ALL /60/ Motor, 1/15 HP ALL /60/ Motor, 1/40 HP ALL /50/ Motor, 1/8 HP ALL 015, /60/ Motor, 1/8 HP ALL 015, /60/ Motor, 1/8 HP ALL 015, /50/ FAN HOUSING & WHEEL Fan Wheel ALL N/A Fan Housing Assembly ALL 015, 019 N/A REFRIGERATION CIRCUIT Reversing Valve ALL 009 N/A Reversing Valve ALL 012 N/A Reversing Valve ALL 015, 019 N/A Solenoid-Reversing Valve ALL ALL N/A SENSOR Air Temp Sensor (DAT & RAT) ALL ALL N/A Water Temp Sensor (LWT & EWT) ALL ALL N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. Q 07/2016 CPL Page 2 of 2

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) Replacement Parts List 057103500 Revision P 03/2016 McQuay Vertical Water Source Heat Pump FCV, FCG & FCW 036 & 042 Vintage B WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) WFDA, WFDD,

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1) Replacement Parts List No. 057103200 Revision K 03/2018 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 007-012 Vintage B WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS 007-012 Design A (1) WFAE,WFAS,WFDD,WFDE,

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101700 Revision B 02/2017 McQuay Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 015-019 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101500 Revision B 02/2017 AAF Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 006-012 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL Applied Decentralized Products Water Source Heat Pump / Rev.A HWH, HWH HWW, HWW PL-1101-4 Nomenclature Nomenclature Field Installed Thermostats & Subbases For Mark IV/AC Control Units Code 03 must be M.

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4 Replacement Parts List No. 700050500 Revision G 07/2018 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 3 009, 012 Design 4 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012 Replacement Parts List No. 700006200 Rev. J 2/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07- Design C (3) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table of Contents

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990 Replacement Parts List No. Revision B /17 McQuay Climate Control Singer Water Source Heat Pump LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW 119 intage B Last Manufactured: 199 To find your Daikin Applied

More information

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982 Replacement Parts List No. 055206500 Revision C 02/2017 McQuay Climate Control Singer Water Source Heat Pump VF, VG, VP 240-400 Vintage C Last Manufactured: 1982 To find your Daikin Applied parts distributor,

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700015400 Revision R 03/2019 McQuay Thinline Vertical Fan Coil FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1 To find your Daikin Applied parts distributor,

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012 Replacement Parts List No. 110511900 Rev. P 1/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07-15 Vintages B and B+ (2) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990 Replacement Parts List No. 055205200 Revision B 05/2003 McQuay Singer Climate Control Water Source Heat Pump LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW 150-190 Vintage C Last Manufactured: 1990 To find

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6) Replacement Parts List No. 70009600 Revision D 0/207 McQuay Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054 UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6) To find your Daikin Applied parts distributor,

More information

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST FHP MANUFACTURING PARTS PRICE LIST All models in this price sheet reflect our current vintage. For discontinued models please contact the factory. To ensure you receive the correct part please have the

More information

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST FHP MANUFACTURING PARTS PRICE LIST All models in this price sheet reflect our current vintage. For discontinued models please contact the factory. To ensure you receive the correct part please have the

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990 Replacement Parts List No. Revision A /99 McQuay Climate Control Singer Water Source Heat Pump LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW 7 intage B Last Manufactured: 99 To find your Daikin Applied parts

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Parts. Package Terminal Air Conditioners. Models and manufacturing numbers in this manual. This Manual Replaces RP Rev. 3.

Parts. Package Terminal Air Conditioners. Models and manufacturing numbers in this manual. This Manual Replaces RP Rev. 3. s Package Terminal Air Conditioners This Manual Replaces RP4210002 Rev. 3. Models and manufacturing numbers in this manual PTC073A00AA PTC073A15AA PTC073A25AA PTC073A35AA PTC074A00AA PTC074A15AA PTC074A25AA

More information

MDT5N25 & MTD5N40 SERVICE PARTS

MDT5N25 & MTD5N40 SERVICE PARTS MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts

More information

Eclipse 2000 Service Parts

Eclipse 2000 Service Parts This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior

More information

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts This part list contains the service parts for the Eclipse 00, 00, and 800 systems. D series models began early 0 The models that are covered include: EH0 C & D EH0 C & D ECC00 ECC00 ECC800 Contents Head

More information

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010 Replacement Parts List No. 700018100 Revision New 07/2010 McQuay Steam/Hot Water Unit Heater UDH 040-960 Vintage C Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011 Replacement Parts List No. 700019800 Revision A 10/2011 McQuay Two-Stage Centrifugal Chiller WTC 500 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

Prodigy Eclipse 600, 800, 1000 Service Parts

Prodigy Eclipse 600, 800, 1000 Service Parts Prodigy Eclipse 600, 800, 000 Service Parts This part list contains the service parts for the Eclipse 600, 800 and 000 systems. The B series references changes to panels. The models that are covered include:

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71332 Issued: 7-7-2011 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE HEAT PUMP Models: PH242-A PH363-A PH302-A PH363-B General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

Parts List. Self-Contained Flaker. Models F-300BAF. hoshizakiamerica.com

Parts List. Self-Contained Flaker. Models F-300BAF. hoshizakiamerica.com Parts List Self-Contained Flaker Models hoshizakiamerica.com Number: 71126 Issued: 10-20-2016 CONTENTS Auxiliary Codes... Note About Ordering Parts... A. Main Assembly... B. Icemaking Unit... 7 C. Water

More information

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500

More information

Parts List. Stackable Crescent Cuber. Models KM-1601SAH/3 KM-1601SWH/3 KM-1601SRH/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601SAH/3 KM-1601SWH/3 KM-1601SRH/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1601SAH/3 KM-1601SWH/3 KM-1601SRH/3 hoshizakiamerica.com Number: 71249 Issued: 8-23-2006 Revised: 9-27-2016 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1601MRJ/3 hoshizakiamerica.com Number: 71394 Issued: 11-1-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly & Refrigeration

More information

Parts List. Self-Contained Cubelet. Models AM-50BAE AM-50BAE-DS AM-50BAE-AD AM-50BAE-ADDS. hoshizakiamerica.com

Parts List. Self-Contained Cubelet. Models AM-50BAE AM-50BAE-DS AM-50BAE-AD AM-50BAE-ADDS. hoshizakiamerica.com Parts List Self-Contained Cubelet Models AM-50BAE AM-50BAE-DS AM-50BAE-AD hoshizakiamerica.com Number: 71211 Issued: 9-23-2002 Revised: 2-15-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017 Replacement Parts List No. 700005300 Revision E 12/2017 McQuay Centrifugal Chiller WPV 320A - 350A Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Modular Flaker Models F-1001MAH(-C)(-22C) F-1001MWH(-C) F-1001MRH(-C) F-1001MLH(-C) A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71196 Issued: 10-29-2001

More information

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

KEY PART # DESCRIPTION KEY PART # DESCRIPTION SINGLE HEAD BEATER SHAFT EF0 Head Dispense w/actuator EF Nozzle, Serrated EF Knob, Hand EF00 Handle Assembly Dispense w/knob EF Knob Ball, /"-, THD Black EF Pin Handle EF Plug for O-Ring, pkg of EF Plug,

More information

Parts List. Modular Crescent Cuber. Models KM-1340MAH, MWH, MRH/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-1340MAH, MWH, MRH/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-1340MAH, MWH, MRH/3 hoshizakiamerica.com Number: 71251 Issued: 5-1-2006 Revised: 9-7-2016 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main

More information

Product Manual C: Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to Watts)

Product Manual C: Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to Watts) MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH Product Manual C: 1155-10 Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to 350 Watts) WATER TO AIR BRINE

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Modular Crescent Cuber Models KMD-700MAH KMD-700MWH KMD-700MRH A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71221 Issued: 5-29-2003 Revised: 1-9-2008 CONTENTS

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

refrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9

refrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9 SHAKE DISPENSE HEAD refrigeration SHAKE #-CMT 0 SHAKE BEATER SEAL EF Head Dispense, Shake side EF Bushing, Beater Bearing EF O-Ring Head EF O-Ring Plunger, Lower, pkg of EF0 O-Ring Plunger, Upper, pkg

More information

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

KEY PART # DESCRIPTION KEY PART # DESCRIPTION Having your serial # ready before ordering ElectroFreeze parts, when calling our sales staff, will ensure speed & accuracy. 9 0 HEAD ASSEMBLY BEATER SHAFT ASSEMBLY EF Beater Shaft EF90 Cylinder Bushing

More information

Replacement Parts Catalog

Replacement Parts Catalog GA Ductfree Series Mini-Split Systems Packaged 18,000-42,000 Terminal BTUH Air Conditioner / Heat Pump 7,000 --- 15,000 BTUH Replacement Parts Catalog 1 Table of Contents Model Number Description Page

More information