Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3

Size: px
Start display at page:

Download "Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3"

Transcription

1 AB-6219-U Specifications/Instructions Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3 General The insertion type HTY78X3/78X6 Temperature/Humidity sensors and HY79X3 Dewpoint temperature sensors are designed to be installed in return air chambers or air handling units to monitor humidity and temperature levels and provide a proportional output for use in heating, ventilating and air conditioning control systems. They are also designed for use in ventilated shields to provide humidity and temperature information for meteorological instrumentation. The sensors use a Pt100 platinum film temperature sensing element for temperature measurement and a polymer capacitive film humidity sensing element (FP3) for humidity measurement. The FP3 have been specifically developed by Yamatake to ensure highly accurate and reliable measurement of space conditions over time. Models are available with two sensors housed in one unit to sense both humidity and temperature (HTY78X3/78X6), a humidity sensor only for just humidity measurement (HY78X3/78X6) or dewpoint temperature sensor only for dewpoint temperature measurent(hy79x3). HTY7803 HTY7813 Features 1) Wide sensing range 2) Excellent long term stability 3) Highly resistant to corrosive environments 4) Quick response to environmental changes 5)High repeatability 6) Easy duct installation (onetouch lever locking mechanism) 7) Splash-proof housing (IP54)ilings Models Model No. Shape Type HTY78 HY78 HY79 Power supply Humidity output Temperature output Accessory Fixed Description Insertion humidity/temperature sonsor Insertion humidity sensor Insertion dewpoint temperature sensor 0 Insertion length: Long 1 Insertion length: Short 3 Accuracy: 3%RH or 1.8 FDP 6 Accuracy: 2%RH T 24 V AC or 24 V DC 6 Humidity output: 0-10 V 4 Humidity output: 4-20 ma 0 Without temperature sensor P Temperature Pt With mounting bracket 0 1

2 Models Available Models AvailableHumidity sensor 3% HTY7803T6P10 Include : Humidity=3% (0-10V), temperature=pt100, Long insertion sensor(hty7803t6p00) and Mounting bracket ( ) HTY7803T4P10 Include : Humidity=3% (4-20mA), temperature=pt100, Long insertion sensor(hty7803t4p00) and Mounting bracket ( ) HTY7813T6P10 Include : Humidity=3% (0-10V), temperature=pt100, Short insertion sensor(hty7813t6p00) and Mounting bracket ( ) HTY7813T4P10 Include : Humidity=3%(4-20mA), temperature=pt100, Short insertion sensor(hty7813t4p00) and Mounting bracket ( ) HY7803T6010 Include : Humidity=3% (0-10V), Long insertion sensor (HY7803T6000) and Mounting bracket ( ) HY7803T4010 Include : Humidity=3% (4-20mA), Long insertion sensor (HY7803T4000) and Mounting bracket ( ) HY7813T6010 Include : Humidity=3% (0-10V), Short insertion sensor (HY7813T6000)) and Mounting bracket ( HY7813T4010 Include : Humidity=3% (4-20mA), Short insertion sensor (HY7813T4000) and Mounting bracket ( ) Humidity sensor 2% HTY7806T6P10 Include : Humidity=2% (0-10V), temperature=pt100, Long insertion sensor (HTY7806T6P00) and Mounting bracket( ) HTY7806T4P10 Include : Humidity=2% (4-20mA), temperature=pt100, Long insertion sensor (HTY7806T4P00) and Mounting bracket( ) HTY7816T6P10 Include : Humidity=2% (0-10V), temperature=pt100, Short insertion sensor (HTY7816T6P00) and Mounting bracket( ) HTY7816T4P10 Include : Humidity=2% (4-20mA), temperature=pt100, Short insertion sensor (HTY7816T4P00) and Mounting bracket( ) HY7806T6010 Include : Humidity=2% (0-10V), Long insertion sensor (HY7806T6000) and Mounting bracket ( ) HY7806T4010 Include : Humidity=2% (4-20mA), Long insertion sensor (HY7806T4000) and Mounting bracket ( ) HY7816T6010 Include : Humidity=2% (0-10V), Short insertion sensor (HY7816T6000) and Mounting bracket ( ) HY7816T4010 Include : Humidity=2% (4-20mA), Short insertion sensor (HY7816T4000) and Mounting bracket ( ) Dewpoint temperature sensor HY7903T6010 Include : Dewpoint temperature (0-10V), Long insertion sensor (HY7903T6000) and Mounting bracket ( ) HY7903T4010 Include : Dewpoint temperature (4-20mA), Long insertion sensor (HY7903T4000) and Mounting bracket ( ) HY7913T6010 Include : Dewpoint temperature (0-10V), Short insertion sensor (HY7913T6000) and Mounting bracket ( ) HY7913T4010 Include : Dewpoint temperature (4-20mA), Short insertion sensor (HY7913T4000) and Mounting bracket ( ) Safety Instructions Please read instructions carefully and use the product properly. Please keep this instruction on hand for reference at any time. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in clean rooms or places where reliability or control accuracy is particularly required, please contact Yamatake s sales representatives. Yamatake bears no responsibility for any benefit, or lack of benefit, derived from the operation by the customer. CAUTION Installer must be a trained, experienced service technician. Check the ratings given in this instructions to prevent equipment damage. Check the environment given in this instructions to prevent equipment damage. Disconnect power supply before wiring to prevent electric shock or equipment damage. All wiring must comply with local codes and ordinances. Do not remove or disassemble casing except for wiring. May result in equipment damage. Product failure may result in excessively high humidity levels. Install high limit controls where appropriate to protect equipment from damage. 2 AB-6219-U

3 Specifications ( HY78X3 ) Item Measurement range Ouput signal Sensing accuracy Time constant (at air velocity 6.56 ft/s (2 m/s)) Environmental conditions Specifications Temp. -4 to 140 F (-20 to 60 C) Humid. 0 to 100 % RH over the range of 23 to 131 F(-5 to 55 C) Temp. 100 / 32 F ( 0 C ) Humid V DC (linear to 0 to 100 % RH) (output impedance: min. 10 k) 4-20 ma DC (linear to 0 to 100 % RH) (maximum permissible load 300 ) Temp. +/ F (0.3 C) over the range of -4 to 140 F ( -20 to 60 C) Humid. +/- 3 % RH over the range of 10 to 90 % RH 77 F ( 25 C) +/- 5 % RH over the range of 10 to 90 % RH 59 to 95 F ( 15 to 35 C) Temp. max. 4 min. Humid. Max. 1 min Temp. Rated operating conditions: -4 to 140 F (-20 to 60 C) 0 to 100 % RH (non-condensing) Extreme operating conditions: -4 to 140 F (-20 to 60 C) 0 to 100 % RH (non-condensing) Storage conditions: -22 to 158 F (-30 to 70 C) 5 to 95 % RH (non-condensing) Humid. Rated operating condtions: 23 to 131 F (-5 to 55 C) 0 to 100 % RH (non-condensing) Extreme operating condtions: -4 to 140 F (-20 to 60 C) 0 to 100 % RH (non-condensing) Storage conditions: -22 to 158 F (-30 to 70 C) 5 to 95 % RH (non-condensing) Air velocity Extreme operating conditions: 0 to 49 ft/s ( 15m/s ) Power supply 24 V AC +10/-15 % (50/60 Hz), 24 V DC +/- 10 % Power consumption 0.2 VA (at conditions of 24 V AC, 0-10 V output model) 150 mw (at conditions of 24 V DC, 0-10 V output model) 1.0 VA (at conditions of 24 V AC, 4-20 ma output model) 800 mw (at conditions of 24 V DC, 4-20 ma output model) Dielectric strength 500 V AC less than 1 ma of leak for 1 minute Insulation resistance 500 V DC min. 20 M Vibration resistance 1G ( 9.8 m/s²) (10 to 150 Hz) Protection Housing IP54 (when splash-proof connectors and designated multi-core cables are used or when designated conduit it used) Installation Duct, air chamber, ventilated shield for meteological instruments (with DY3002A1005) Wiring Terminal block connection Material Housing: GF20 % Polycarbonate mixed resin, gray (equivalent to DIC-651) Filter cap: Denatured PPE resin, gray (equivalent to DIC-651) Weight Approx. 0.53lb (240 g) (7803 series) Approx. 0.46lb (210 g) (7813 series) Accessories Mounting bracket Seal connector Order separatly DY3002A1005 Ventilated shield mounting bracket (L shape metal) Order separately for maintenance Filter set HTY78*3/HY78*3 series have passed the following tests: EN /1992 (EN55011/1998 group 1, class B) EN /1997 (EN , EN , ENV50204, EN , EN , EN , EN ) 3 AB-6219-U

4 Specifications ( HY78X6 ) Item Measurement range Ouput signal Sensing accuracy Time constant (at air velocity 6.56 ft/s (2 m/s)) Environmental conditions Specifications Temp. -4 to 185 F (-20 to 85 C) Humid. 0 to 100 % RH over the range of 4 to 140 F(-20 to 60 C) Temp. 100 / 32 F ( 0 C ) Humid V DC (linear to 0 to 100 % RH) (output impedance: min. 10 k) 4-20 ma DC (linear to 0 to 100 % RH) (maximum permissible load 300 ) Temp. +/ F (0.3 C) over the range of -4 to 185 F ( -20 to 85 C) Humid. +/- 2 % RH over the range of 5 to 95 % RH 77 F ( 25 C) +/- 3 % RH over the range of 5 to 95 % RH 41 to 140 F ( 5 to 60 C) Temp. max. 4 min. Humid. Max. 1 min Temp. Rated operating conditions: -4 to 185 F (-20 to 85 C) 0 to 100 % RH (non-condensing) Extreme operating conditions: -4 to 185 F (-20 to 85 C) 0 to 100 % RH (non-condensing) Storage conditions: -22 to 158 F (-30 to 70 C) 5 to 95 % RH (non-condensing) Humid. Rated operating condtions: -4 to 185 F (-20 to 85 C) 0 to 100 % RH (non-condensing) Extreme operating condtions: -4 to 185 F (-20 to 85 C) 0 to 100 % RH (non-condensing) Storage conditions: -22 to 158 F (-30 to 70 C) 5 to 95 % RH (non-condensing) Air velocity Extreme operating conditions: 0 to 49 ft/s ( 15m/s ) Power supply 24 V AC +10/-15 % (50/60 Hz), 24 V DC +/- 10 % Power consumption 0.6 VA (at conditions of 24 V AC, 0-10 V output model) 450 mw (at conditions of 24 V DC, 0-10 V output model) 1.4 VA (at conditions of 24 V AC, 4-20 ma output model) 1.2 mw (at conditions of 24 V DC, 4-20 ma output model) Dielectric strength 500 V AC less than 1 ma of leak for 1 minute Insulation resistance 500 V DC min. 20 M Vibration resistance 1G ( 9.8 m/s²) (10 to 150 Hz) Protection Housing IP54 (when splash-proof connectors and designated multi-core cables are used or when designated conduit is used) Installation Duct, air chamber, ventilated shield for meteological instruments (with DY3002A1005) Wiring Terminal block connection Material Housing: GF20 % Polycarbonate mixed resin, gray (equivalent to DIC-651) Filter cap: Denatured PPE resin, gray (equivalent to DIC-651) Weight Approx. 0.53lb (240 g) (7806 series) Approx. 0.46lb (210 g) (7816 series) Accessories Mounting bracket Seal connector Order separatly DY3002A1005 Ventilated shield mounting bracket (L shape metal) Order separately for maintenance Filter set HTY78*6/HY78*6 series have passed the following tests: EN /1992 (EN55011/1998 group 1, class B) EN /1997 (EN , EN , ENV50204, EN , EN , EN , EN ) 4 AB-6219-U

5 Specifications ( HY79X3 ) Item Specifications Measurement range Dewpoint -40 to 140 FDP (-40 to 60 CDP) over the range of 4 to 140 F ( -20 to 60 C ) Ouput signal Dewpoint 0 10 V DC ( linear to 4 to 140 FDP ) ( output impedance : min. 10k ) 4 20 ma DC ( linear to 4 to 140 FDP ) ( maximum permissible load 300 ) Sensing accuracy Dewpoint +/- 1.8 FDP ( 1 C DP ) over the range of 10 to 90 % RH 77 F( 25 C ) +/- 4.5 FDP ( 2.5 C DP ) over the range of 10 to 90 % RH 23 to 140 F ( -5 to 60 C ) Time constant (at air velocity 6.56 ft/s (2 m/s)) Dewpoint Max. 1 min. ( when temperature is constant ) Environmental Dewpoint Rated operating condtions: 23 to 140 F ( -5 to 60 C ) 10 to 100 % RH (non-condensing) conditions Extreme operating condtions: -4 to 140 F (-20 to 60 C) 0 to 100 % RH (non-condensing) Storage conditions: -22 to 158 F (-30 to 70 C) 5 to 95 % RH (non-condensing) Air velocity Extreme operating conditions : 0 to 49 ft/s ( 15m/s ) Power supply 24 V AC +10/-15 % (50/60 Hz), 24 V DC +/- 10 % Power consumption 0.6 VA (at conditions of 24 V AC, 0-10 V output model) 450 mw (at conditions of 24 V DC, 0-10 V output model) 1.4 VA (at conditions of 24 V AC, 4-20 ma output model) 1.2 mw (at conditions of 24 V DC, 4-20 ma output model) Dielectric strength 500 V AC less than 1 ma of leak for 1 minute Insulation resistance 500 V DC min. 20 M Vibration resistance 1G ( 9.8 m/s²) (10 to 150 Hz) Protection Housing IP54 (when splash-proof connectors and designated multi-core cables are used or when designated conduit is used) Installation Duct, air chamber, ventilated shield for meteological instruments (with DY3002A1005) Wiring Terminal block connection Material Housing: GF20 % Polycarbonate mixed resin, gray (equivalent to DIC-651) Filter cap: Denatured PPE resin, gray (equivalent to DIC-651) Weight Approx. 0.53lb (240 g) (7903 series) Approx. 0.46lb (210 g) (7913 series) Accessories Mounting bracket Seal connector Order separatly DY3002A1005 Ventilated shield mounting bracket (L shape metal) Order separately for maintenance Filter set HTY79*3/HY79*3 series have passed the following tests: EN /1992 (EN55011/1998 group 1, class B) EN /1997 (EN , EN , ENV50204, EN , EN , EN , EN ) 5 AB-6219-U

6 Dimensions inches (mm) Sensor head Housing Cover A (247.6) (51.3) (45.6) (67.3) A (20) (110) (113.5) (70) (1)7803,7806,7903 series 6 AB-6219-U

7 4.276 (108.6) (51.3) (45.6) (67.3) (20) (110) (113.5) (2)7813,7816,7913 series (70) (30) (25) (50) (60) (62.5) (72.3) (3.3) (40) (60) (3)Mounting bracket 7 AB-6219-U

8 Installation Important 1) Select a location where the typical temperature and humidity of the duct airstream can be sensed and the air velocity requirements are met. 2) Insert the sensor head into the duct. Make sure that the temperature and humidity elements are entirely immersed in the airstream, and that air can pass over the sensor head. 3) Allow adequate clearance in front of the cover for servicing the sensor. 4) When installing in a steam heating air handling unit, make sure the sensor head is not directly exposed to the steam. The operating conditions for the sensor may be exceeded. 5) Prevent condensation on the sensor head when inserting the sensor head into the airstream. Measurment errors may occur until the condensation is dried. CAUTION Do not use the unit as a step. Mounting sensor to the duct 1) Prepare the mounting bracket in advance. Attach the mounting template to the duct at the chosen sensor mounting position. Cut a hole (1.26 ) in the duct at the point indicated on the template. Mount the bracket to the duct with M4 screws, inserting the gasket between the duct and the mounting bracket before inserting the screws. Cover the duct with insulating material. (NOTE : If you cover the duct with an insulating material first, fill the clearance between the bracket and the duct with the insulating material after the bracket is mounted.) the grooves in the mounting bracket attached to the duct. Secure the sensor to the duct mouting bracket by rotating the mounting lever 45to positions (2) as shown below. (1) 45 (2) Mounting lever Protrutions Mounting sensor to the equipment 1) Prepare the mounting bracket in advance. Attach the mounting template to the duct at the chosen sensor mounting position. Cut a hole (1.26 ) in the duct at the point indicated on the template. Mount the bracket to the duct with M4 screws, inserting the gasket between the duct and the mounting bracket before inserting the screws. Panel Panel Grooves Duct Duct Air flow Gasket Insulating material Air flow 2) Rotate the mounting lever of the sensor all the way to the left (1) and insert the sensor head into the bracket, aligning the protrutions on the sensor mounting plate to the grooves in the mounting bracket attached to the duct. Secure the sensor to the duct mouting bracket by rotating the mounting lever 45to positions (2) as shown below. Air flow 2) Rotate the mounting lever of the sensor all the way to the left (1) and insert the sensor head into the bracket, aligning the protrutions on the sensor mounting plate to 8 AB-6219-U

9 Wiring 45 (2) (1) Stopper Claw 1) Remove the cover.screw the threaded seal connector into the case and pull the wiring cable through it. Wiring Instructions Shielded multi-wire cables with 16 or 12 AWG (1.25 mm² or 2 mm²) must be used. Be sure to ground the shielded cable on the controller side. If you don't need a splash-proof installation, standard 16 or 12 AWG (1.25 mm² or 2 mm²) wire may be used for power and a 16 AWG (1.25 mm²) shielded cable for humidity and temperature signals. The maximum cable length is 327 ft (100 m). Never connect power supply leads to the temperature output terminals. Always check wiring before applying power. Use a dedicated 24V AC transformer for power. Never share 24 V AC transformer with other products. Seal connector 2) Connect the wires to the wiring terminals and close the cover. Tighten the seal connector only after the wiring has been connected to the wiring terminals. Allow sufficient service clearance Tighten (+) Power supply ( ) + Humidity Temperatur A B B V AC (24 V DC) 0-10 V DC 4-20 ma Pt 100 HTY7803T6P00 HTY7803T4P00 HTY7813T6P00 HTY7813T4P00 HTY7806T6P00 HTY7806T4P00 HTY7816T6P00 HTY7816T4P00 HY7803T6000 HY7803T4000 HY7813T6000 HY7813T4000 HY7903T6000 HY7903T4000 Terminal Nos. 9 AB-6219-U

10 Use a dedicated 24V AC transformer of humidity Sensor CAUTION Use a dedicated insulated transformer to supply 24 V AC power supply voltage Never share 24 V AC power supply with other equipment. If a transformer is shared with other equipment, a loop may be formed at common and the sensor may be damaged. If using the sensor with another manufacture s controller, follow these instructions to prevent an induction current flowing from the humidity sensor to the controller input circuit, or to prevent excessive noise due to a different controller time constant. Use a controller with a low pass filter having a removal ratio of 40dB or higher (normal mode). Connect an isolator to the controller input circuit if a removal ratio is unknown. Transformer (24 V AC power supply) shared 24 V AC Temperature / humidity sensor Multi-loop controller Temperature / humidity sensor Common share Not Good Common loop formed Transformer (24 V AC) separated Temperature / humidity sensor 24 V AC Multi-loop controller 24 V AC Temperature / humidity sensor Good No common loop formed 24 V DC power shared 24 V DC Temperature / humidity sensor Multi-loop controller Temperature / humidity sensor Good Common loop formed, however, not so affected by common mode noise. 10 AB-6219-U

11 Maintenance The temperature and humidity sensor have been factory calibrated and need no adjustments prior to installation. However, to maintain proper operation the equipment should be inspected periodically : 1) Periodical inspection The equipment should be inspected for build-up of duct and dirt that may affect the sensor performance. Regularly check the sensor s accuracy and condition of it. 2) Troubleshooting If any problem occurs during operation, refer to the following troubleshooting guide (below) for appropriate solutions. Troubleshooting Problem Check Action - No output generated - Unstable output - Check for loose wiring connection - Check for Incorrect wiring - Check supply voltage - Check sensor for damage - Reconnect the wire - Replace sensor - Slow response - Error in output - Check the sensor for water leakage or condensation - Check the installed location - Check for dust, soil build-up. - Tum off the power - Remove the sensor from the mounting bracket. Dry the unit. - Refer to the Installation instructions - Clean filter - Replace filter - Humidity one point adjustment - Replace sensor 3) Replacing the filter: (1) Prepare filter set (order separately) in advance. Remove the filter cap and filter as shown below. Loosen Filter cap (The cap will remove with the filter inside.) (2) Cover the sensor with the new filter and then put the new filter cap over it. Filter cap (3) Tighten the filter cap. 4) Humidity one point adjustment If you find a calibration error in the humidity sensor during the periodic inspections, re-calibrate the sensor using the adjustment volume (VR1, VR2) located on the circuit board. The output value is increased by turning it this volume in clockwise direction and decreased by turning counterclockwise. A humidity sensor with higher accuracy than the Yamatake sensor should be used as a reference. A digital multimeter is recommended to check the output voltage. Cautions Tighten Filter cap Rough adjustment knob (VR2) Fine adjustment knob (VR1) Identification of adjustment volume location 1. After unpacking, condition the sensor in the ambient atmosphere for at last 24 hours before using the output for control. 2. During calibration and adjustment, make sure that heat from the human body or appliances is not affecting the output. Filter 11 AB-6219-U

12 Specifications are subjects to change without notice. Yamatake Sensing Control Limited 1400 Coleman Ave., Suite E22, Santa Clara CA95050 Customer Service:1-866-SENSOR2( ) Sales:1-866-SENSOR1( ) Yamatake Corporation International Business Division Totate International Bldg , Shibuya, Shibuya-Ku Tokyo, , Japan First Printing Dec AB-6219-U Printed in Japan. AB-6219-U 5H-H (W)

Direct Coupled Damper Actuator Model MY6050A1001

Direct Coupled Damper Actuator Model MY6050A1001 Specifications/Instructions Direct Coupled Damper Actuator General direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY6050A00 provides -position or floating control

More information

Pressure Transmitter

Pressure Transmitter Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water,

More information

Direct Coupled Damper Actuator Model MY9050A1001

Direct Coupled Damper Actuator Model MY9050A1001 AB-4 Specifications/Instructions Direct Coupled Damper Actuator Model MY9050A00 General Model MY9050A00 direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY9050A00 contains

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200) Specifications/Instructions ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200) General ACTIVAL Model VY54X0F is a series of motorized three-way valves with flanged connection.

More information

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS CP-UM-306E ECM3000 Control Motor User's Manual WARNING Be sure to turn the power OFF before mounting, removing, or wiring the ECM3000 or opening the cover. Touching electrically charged parts such as power

More information

Valve Linkages Models Q455C, Q455D, Q455F

Valve Linkages Models Q455C, Q455D, Q455F Specifications/Instructions Valve Linkages Models Q455C, Q455D, Q455F General Model Q455C / Q455D / Q455F valve linkage series connects the Model MY3000 Control Motor and a control valve. The crank mechanism

More information

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A)

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A) Specifications/Instructions ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A) General ACTIVAL Model VY51XXJ for high differential

More information

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A) Specifications/Instructions ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A) General ACTIVAL Models VY51XXK and VY51XXH are series of motorized

More information

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve Specifications/Instructions ElectroMechanical Actuator for Control Ball Valve General Model MY3X0A actuator is designed specifically for Models VY30 twoway and VY303 threeway proportional control ball

More information

Motorized Two-Way Ball Valve with Screwed-End Connection

Motorized Two-Way Ball Valve with Screwed-End Connection Specifications/Instructions Motorized Two-Way Ball Valve with Screwed-End Connection General Model VY6300A/VY6300B is a series of motorized two way ball valve with screwed-end connection. Models VY6300A

More information

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve Model MY53X0AX000

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve Model MY53X0AX000 A690 Specifications/Instructions ElectroMechanical Actuator for Control all Valve Model MY3X0AX000 General Model MY3X0A actuator is designed specifically for Models VY30 twoway and VY303 threeway proportional

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

NV Direct Coupled Globe Valve Actuator

NV Direct Coupled Globe Valve Actuator 70396 Rev. C Non-spring return, on/off, floating point, proportional control NV Direct Coupled Globe Valve Actuator NV24-3 US NVD24-3 US NV24-MFT US NVD24-MFT US Application For on/off, floating point

More information

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary Document No. 155-785 OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary Description The OpenAir direct coupled enhanced non-spring return rotary electric actuators are designed

More information

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information MEMS Air Velocity Sensor Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection. Precision uni-directional air velocity detection. Integral passive Dust Segregation

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Sensors for Humidity and Temperature for industrial applications from -80...00 C and up to 5 bar AK... with SVKA.0E... duct version up to 150

More information

ACTIVAL Two-way Ball Valve with Threaded-end Connection

ACTIVAL Two-way Ball Valve with Threaded-end Connection Specifications/Instructions ACTIVAL Two-way Ball Valve with Threaded-end Connection General ACTIVAL Model VY5302A is a two-way ball valve with threaded-end connection (ISO 7-1: 1994). It proportionally

More information

Insertion Thermostat

Insertion Thermostat Specifications/Instructions Insertion Thermostat General Models TY6800Z and TTY6800Z are insertion thermostats applicable to control temperature (twoposition) for air in duct and liquid in tank or pipe.

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor Ideal for Narrow Mounting Space Grooved TL-G3D is ideal for high-speed pulse generator and high-speed revolution control. TL-Q2 and TL-Q5 save mounting space

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System Description of Device VALMAC Posi-Zest SP-2100 Series is the advanced control device for a rotary control valve that provides unparalleled stability in difficult environments. Easy Maintenance Precise

More information

M100F Incremental Motor Actuator R81F Interface Board

M100F Incremental Motor Actuator R81F Interface Board Installation Sheets Manual 121 Motor Actuators Section M Technical Bulletin M100F Issue Date 0493 M100F Incremental Motor Actuator R81F Interface Board Application Details Figure 1: M100 Motor Actuator

More information

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-6704-0. Fax

More information

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (PN16 / GG-20) (Spring Return Type Actuator)

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (PN16 / GG-20) (Spring Return Type Actuator) Specifications/Instructions Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (PN16 / GG-20) (Spring Return Type Actuator) General ACTIVAL Models VY5168K and VY5168H

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

HUMIDITY / TEMPERATURE TRANSMITTER

HUMIDITY / TEMPERATURE TRANSMITTER HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY

More information

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control Technical Instructions EA 599-7 Description The Flowrite EA 599 Series SQX electronic valve actuator requires a 24 Vac supply

More information

Intelligent Component Series ACTIVAL Electro-Mechanical Actuator for Model VY530X Control Ball Valve Model MY5390A

Intelligent Component Series ACTIVAL Electro-Mechanical Actuator for Model VY530X Control Ball Valve Model MY5390A Specifications/Instructions Intelligent Component Series ACTIVAL Electro-Mechanical Actuator for Model VY530X Control Ball Valve Model MY5390A General Model MY5390A actuator is designed specifically for

More information

ACTIVAL Three-Way Ball Valve with Threaded-End Connection

ACTIVAL Three-Way Ball Valve with Threaded-End Connection -6209 Specifications/Instructions CTIVL Three-Way all Valve with Threaded-End Connection General CTIVL Model VY5303 is a three-way ball valve with threaded-end connection (ISO 7-1: 1994). It proportionally

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...

More information

Filterpack FR-BFP2-(H)0.4K to (H)15K

Filterpack FR-BFP2-(H)0.4K to (H)15K INVERTER INSTRUCTION MANUAL FR-BFP2-(H)0.4K to (H)15K 1. Product Checking... 1 2. Applicable Inverter... 1 3. Installation... 2 3.1 Inverter Installation (installation of the )...2 4. Wiring... 4 5. Main

More information

VOC Duct and Rough Service Sensor

VOC Duct and Rough Service Sensor Overview and Identification Humans respirate Volatile Organic Compounds (VOCs) as well as CO 2. The BAPI sensor measures these VOCs and indicates space occupancy just as well as a CO 2 sensor. The advantage

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional

More information

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm Compact Square Inductive Proximity Sensor World s Smallest Square Sensor with uilt -in Amplifier 5.5 x 5.5 mm type contributes to smaller, space-- saving machines and devices. Comprehensive range; sensing

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A)

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) Specifications/Instructions Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) General ACTIVAL Model VY516XJ is a series of motorized two-way

More information

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9. Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation

More information

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System Description of Device VALMAC Posi-Zest SP-2000 Series is the advanced control device for a linear control valve that provides unparalleled stability in difficult environments. Easy maintenance Precise

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection <4-20 ma DC Input with 4-20 ma DC Feedback Output> (JIS 10K-FC200, -SCS13A)

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection <4-20 ma DC Input with 4-20 ma DC Feedback Output> (JIS 10K-FC200, -SCS13A) Specifications/Instructions ACTIVAL Motorized TwoWay Valve with FlangedEnd Connection (JIS 10KFC200, SCS13A) Overview ACTIVAL Model VY519_J is a series

More information

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS SLC-811X Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Single Loop Proportional Temperature Controller General Instructions APPLICATION Electronic temperature controller

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve ElectroMechanical Actuator for Control Ball Valve AB690 Specifications/Instructions Overview Model MY3_0A actuator is designed specifically for Models VY3_ twoway and VY3_3 threeway proportional control

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual Electro-Pneumatic Positioner Series 830/831-WP/EX Operation & Maintenance Manual Electro-Pneumatic Positioner Model 830/831- WP/EXP This operation & maintenance manual corresponds to Forbes Marshall Arca

More information

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) (Spring Return Type Actuator)

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) (Spring Return Type Actuator) Specifications/Instructions Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) (Spring Return Type Actuator) General ACTIVAL Models VY516XK

More information

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet AKF10+ Duct-/Immersion temperature sensor Datasheet Subject to technical alteration Issue date: 26.03.2018 A002 Application Duct/Immersion sensor for measurement of air temperature and other gaseous mediums

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners. INSTALLATION & OPERATING INSTRUCTIONS SERIES 40 Positioners Form IO2-0406 Description of Device Moniteur's Series 40 pneumatic (3-15psi) and electropneumatic (4-20mA) positioners are advanced control devices

More information

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with

More information

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application Document No. 155-180P25 Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description The Flowrite 599 Series SKD6xU Electronic Valve Actuators require a 24 Vac supply and

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER THT-500-A/R No.THT51E1 2017.12 Thank you for purchasing our THT-500-A/R, Temperature and Humidity Transmitter (mounted within control panel). This

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS BATTERY CHARGER IR-200BC TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. HANDLING PRECAUTIONS... 3 4. NOMENCLATURE AND FUNCTIONS... 4 5. CHARGING... 5

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control Technical Instructions Document No. 155-176P25 EA GBB/GIB-1 Description The OpenAir, non-spring return (NSR),

More information

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet AKF10+ Duct-/Immersion temperature sensor Datasheet Subject to technical alteration Issue date: 04.07.2018 A005 Application Duct/Immersion sensor for measurement of air temperature and other gaseous mediums

More information

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control Document No. 155-176P5 EA GBB/GIB-1 OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 4 Vac - Modulating Control Description The OpenAir direct coupled 4 Vac non-spring return (NSR) rotary electric

More information

SA1W: Water Detection Sensors

SA1W: Water Detection Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com The SA1W is the fastest, most reliable

More information

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V Duct Sensor Humidity / Temperature Duct mounted combined humidity (VDC) and temperature sensor. 2% accurate rh, available with dual active outputs or passive for temperature. Nema 4X / IP65 rated enclosure.

More information

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Document No. 155-507 Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Description The Flowrite 599 Series SAX Non-spring Return (NSR), Electronic Valve Actuator

More information

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18) AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or

More information

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21) EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp

More information

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Model No. DFC-X Support 877-351-4702 DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual covers the following products: DFC-X TS-01 DFTD RDU DAT-12 PWM-10V

More information

ML7421A,B Electric Linear Valve Actuator

ML7421A,B Electric Linear Valve Actuator ML7421A,B Electric Linear Valve Actuator FEATURES PRODUCT DATA Quick and easy installation. No separate linkage required. 3/4 in. (20 mm) stroke on ML7421A; 1-1/2 in. (38 mm) stroke on ML7421B. No adjustments

More information

MEMS Gauge Pressure Sensor

MEMS Gauge Pressure Sensor MEMS Gauge Pressure Sensor MEMS Gauge Pressure Senser Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Superior electrical characteristics to capative type pressure

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

TK-6024, TK-6124, TK-8024, TK-8124

TK-6024, TK-6124, TK-8024, TK-8124 TK-6024, TK-6124, TK-8024, TK-8124 Pneumatic Bulb Thermostats General Instructions APPLICATION For proportional temperature control of pneumatic valves and actuators to maintain air or liquid temperatures

More information

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications Description VG series accurately regulate the flow of water or steam in response to the demand of a controller in heating,ventilating and air conditioning systems. These valves are available in normally

More information

ILLUSTRATION ILLUSTRATION

ILLUSTRATION ILLUSTRATION ILLUSTRATION ILLUSTRATION REMOVAL 1. DISABLE BRAKE CONTROL (a) Wait at least 2 minutes after the power switch off. When the brake pedal is depressed or the door courtesy switch is turned on even if the

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

- Wiring Brochure Zone Manager 336

- Wiring Brochure Zone Manager 336 - Wiring Brochure W 336 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring Brochure Wiring

More information

SAV Electronic Valve Actuator

SAV Electronic Valve Actuator Document No. 155-548 Non-spring Return, 24 Vac/dc, 3-Position Control Description The SAV Non-spring Return (NSR), Electronic Valve Actuator requires a 24 Vac/dc supply to provide three-position (floating)

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

Hour Meter Series HM36

Hour Meter Series HM36 Robust design with high degree of Accuracy and Compact size Frequency independent for AC applications Indicates operating time in hours and tenths with running indicators Totally sealed from Dust and Moisture

More information

C7170A,B Encapsulated Temperature Sensor

C7170A,B Encapsulated Temperature Sensor C7170A,B Encapsulated Temperature Sensor The C7170A,B Temperature Sensors are for use with electronic controllers where linear PTC sensors are required (W7100, W7600, W7620, or Excel 500, for example),

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal

More information

MF /MS Series

MF /MS Series MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic

More information

V4043 and V4044 Motorized Valves

V4043 and V4044 Motorized Valves V03 and V0 Motorized Valves INSTALLATION INSTRUCTIONS FEATURES V0 These valves consist of an actuator motor and valve assembly for controlling the flow of hot or cold water. The V03 provides 2-position,

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

SIGNET Temperature Transmitter

SIGNET Temperature Transmitter SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

HS6B Series Subminiature Interlock Switch

HS6B Series Subminiature Interlock Switch HS6B Series Subminiature Interlock Switch HS6B features: Only 78 x 30 x 15mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1, EN954-1) Two actuator

More information

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2 The SA1W is the fastest, most reliable liquid detection sensor on the market. Using a laser beam tuned to the resonant frequency of an H 2 O molecule, the SA1W is able to detect any liquid containing water

More information