New Brunswick Products. Operating Manual M Revision N+

Size: px
Start display at page:

Download "New Brunswick Products. Operating Manual M Revision N+"

Transcription

1 New Brunswick Products Operating Manual M Revision N+

2 The enclosed Operating Manual was originally produced by the New Brunswick Scientific Company, Inc. About Eppendorf Eppendorf is a biotech company which develops, produces and distributes systems for use in life-science research laboratories worldwide. After more than 60 years the vision of the company is just as valid and up-to-date as it ever was: our goal is to improve the living conditions of man. Since 945 we have succeeded in continually producing high-quality products and technology, integrated as systems which solve problems in a holistic way. Information about Eppendorf is available online at: About New Brunswick Scientific New Brunswick Scientific, purchased by Eppendorf in 007, was founded in 946 and is a global leader in the design and manufacturing of advanced biotechnology equipment. New Brunswick Scientific s innovative systems are used in a broad range of research and commercial applications, spanning biomedical, environmental, food and cosmetic sciences. With the world s largest selection of lab shakers and a comprehensive line of fermentors, bioreactors, CO incubators and freezers, New Brunswick Scientific is proud to support the groundbreaking advances of its customers worldwide. Information about New Brunswick Scientific is available online at: For information related to warranty or service, please contact your local Eppendorf sales organization or distributor: Eppendorf and the Eppendorf logo are registered trademarks of Eppendorf AG, Germany. New Brunswick is a trademark of Eppendorf AG, Germany. All rights reserved, including graphics and photos. Copyright 0. New Brunswick Scientific 75 Freshwater Boulevard Enfield, CT , USA Tel.: bioinfo@nbsc.com

3 ENVIRONMENTAL INCUBATOR SHAKER MODEL G-4 WITH DIGITAL DISPLAY MANUAL NO.: M REVISION N NEW BRUNSWICK SCIENTIFIC CO., INC. BOX TALMADGE ROAD. EDISON, NJ TELEPHONE: FAX: TELEX: 4750 NBSCO INTERNET: bioinfo@nbsc.com

4 WARRANTY Every instrument manufactured by the New Brunswick Scientific Co., Inc. is warranted to be free from defects in material and workmanship. This apparatus, with the exception of glassware, lamps and electrodes (where supplied), is warranted for one year against faulty components and assembly and our obligation under this warranty is limited to repairing or replacing the instrument or part thereof, which shall within one year after date of shipment, prove to be defective after our examination. This warranty does not extend to any NBS products which have been subjected to misuse, neglect, accident or improper installation or application; nor shall it extend to products which have been repaired or altered outside the NBS factory without prior authorization from New Brunswick Scientific Co., Inc.. In addition to the above, all biological shakers shipped to the USA and Canada carry an additional one-year warranty. NEW BRUNSWICK SCIENTIFIC MODEL G-4

5 TABLE OF CONTENTS INTRODUCTION Scope of Manual... Description of the Equipment... Supplementary Drawings... INSTALLATION Inspection... Installation Procedure... Heat Exchanger Installation Installation Of Platform... 4 Installation Of Clamps...4 Control for G OPERATION PAGE NO. MAINTENANCE Preventive Maintenance...0 Cleaning...0 Periodic Inspection...0 Corrective Maintenance... Replacement of Drive Belt... Platform Removal... Drive Motor Lubrication... Bearing Lubrication... Drive Motor Brush Replacement... Bearing Replacement.... Replacement Parts... Calibration Procedure... 6 Converter Board Calibration (Fig. )...6 Clamp Mounting Hardware Kit... 7 NEW BRUNSWICK SCIENTIFIC MODEL G-4

6 IMPORTANT NOTICE RETURN MATERIAL AUTHORIZATION POLICY NO RETURNED MATERIAL OR EQUIPMENT WILL BE ACCEPTED WITHOUT A RETURN AUTHORIZATION WHICH IS ISSUED BY THE SERVICE DEPARTMENT. CALL THE SERVICE DEPARTMENT FOR RETURN AUTHORIZATION AT: THE RETURN AUTHORIZATION NUMBER MUST APPEAR ON THE OUTSIDE OF ALL CARTONS. NEW BRUNSWICK SCIENTIFIC MODEL G-4

7 NEW BRUNSWICK SCIENTIFIC MODEL G-4

8 INTRODUCTION SCOPE OF MANUAL This Manual contains Installation, Operation and Maintenance instruction for the Digital Environmental Incubator Shaker Model G-4 manufactured by the New Brunswick Scientific Co., Inc., P.O. Box 4005, 44 Talmadge Road, Edison, New Jersey DESCRIPTION OF THE EQUIPMENT The Model G-4 is a combination shaker-incubator. Temperature ranging from ambient to 60 C can be maintained in the chamber with an accuracy of 0.5 C. The Shaker has a speed range of 40 to 500 RPM. For specific requests, a wide selection of shaker platforms are available, including accessories for Erl Angle Flasks. SUPPLEMENTARY DRAWINGS Supplementary drawings supplied with this manual are listed as follows: Control Schematic and Wiring Diagram NEW BRUNSWICK SCIENTIFIC MODEL G-4

9 INSTALLATION INSPECTION Inspect the unit carefully for any apparent damage which may have occurred during transit. Report any obvious damage to the carrier and to the New Brunswick Scientific Co., Inc. INSTALLATION PROCEDURE. The Shaker should be located in an area which provides ample space for operation and servicing. For efficient temperature control, install the apparatus in a shaded area away from any sources of excessive heat; such as the sun or radiators.. Place the unit on a firm level table. The unit is ready for operation as delivered. Set the Power switch to OFF. Check the Electrical Specification Plate on the unit to verify that the correct voltage and frequency are being used and then connect the power cord to a suitable electrical outlet. HEAT EXCHANGER INSTALLATION - Optional Equipment An optional Heat Exchanger is available which utilizes water for cooling. The Heat Exchanger can be ordered as a factory installed option or may be purchased separately and added to units which were not originally equipped. The optional field installation Heat Exchanger is available as a kit with all of the necessary hardware and tubing required for operation. The Heat Exchanger, when installed, is mounted directly in front of the heater/fan assembly in the chamber. During operation, cold water is circulated through the Heat Exchanger through Tygon tubing. The temperature of the chamber may be brought down to within several degrees of the water temperature depending upon ambient conditions. If the unit is factory equipped with a heat exchanger, disregard the following procedure.. Remove power from the shaker and all flasks, test-tubes, etc., from the chamber.. Remove the platform from the chamber.. Refer to the Heat Exchanger Installation drawing M06-00 and note the position of the Heat Exchanger. 4. Remove the two screws holding the heater deflector shroud inside the chamber. Remove the shroud. NEW BRUNSWICK SCIENTIFIC MODEL G-4

10 INSTALLATION NOTE: On older style cabinets, two large holes will have to be drilled inside the cabinet to accept the tubing from the Heat Exchanger. These holes are identified as U 5/6 on Drawing M Two additional holes are required at the rear of the cabinet for the installation of serrated fittings. These are identified as P /6. Newer style cabinets have pre-drilled holes at both locations. 5. Install the two grommets supplied in the large holes to the right side of where the Heat Exchanger is to be mounted. 6. Place the Heat Exchanger in place and mark the base of the chamber where two holes are to be drilled. Use a #9 drill and drill both locations. 7. Using the screws removed and screws supplied, screw the Heat Exchanger in place. Check that the grommets are properly installed. 8. Install the two serrated fittings at the rear of the Shaker. Make sure the spacer is in position on each fitting. See Drawing M06-00 for details. 9. Install the two pieces of Tygon tubing from the tubing on the Heat Exchanger to the newly installed serrated fittings. 0. Install the four clamps on the tubing as shown on the drawing.. Replace the platform and reconnect power cord. Unit is now ready for operation. NEW BRUNSWICK SCIENTIFIC MODEL G-4

11 INSTALLATION INSTALLATION OF PLATFORM A platform must be installed on the unit prior to use. The unit is shipped with the four Allen head platform screws installed in the subplatform of the bearing housing. These screws must be removed before attempting to install a platform.. Set the power switch to the off position. Open the cover.. Using the hex wrench provided, remove the four Allen head platform screws from the subplatform.. Place the platform on the subplatform. 4. Tighten the four platform Allen head screws with the wrench to secure the platform. INSTALLATION OF CLAMPS Flask clamps purchased for use with universal platforms require installation. Clamps are installed by securing the base of the clamp to the platform with the correct type and number of screws (refer to clamp hardware application charts). All clamps are shipped complete with hardware. Clamps for to 6 liter flasks are shipped with an additional girdle to keep the flasks in place. To install to 6 liter clamps, perform the following:. Place clamp on platform, secure in place with correct type of screws (refer to clamp hardware application charts).. Place the loose girdle around the upper portion of clamp body so that it is held in place by the legs of the clamp. Insert the flask into the clamp. NEW BRUNSWICK SCIENTIFIC MODEL G-4 4

12 INSTALLATION to 6 Liter Clamp Installation PLATFORM CLAMP MOUNTING HOLES (5) UPPER GIRDLE WITH GIRDLE TUBES LOWER GIRDLE WITH GIRDLE TUBES CLAMP BODY (LEGS AND BASE) NOTE: 800 ml Fernbach Flask Clamp applicable to above. NBS flask clamps are used on a variety of shaker platforms. Flat head screws of different lengths and thread pitch are used to secure the clamp. The following tables identify the proper screw for your shaker application by reference to the head style. 0 to 500 ml Clamp Hardware Application Chart Description Part Number Qty. Application 0-4 x 5/8 (5.87 mm) S6-0 /4" (9.05 mm) thick flat Phillips (+) head screw wood platform 0-4 x 5/6 (7.9 mm) flat Phillips (+) head screw 0- x 5/6 (7.9 mm) flat slotted (-) head screw S6-05 5/6" (7.9 mm) thick aluminum, phenolic and stainless steel platforms. S7-050 all stainless steel platforms NEW BRUNSWICK SCIENTIFIC MODEL G-4 5

13 INSTALLATION to 6 Liter Clamp Hardware Application Chart Description Part Number Qty. Application 0-4 x 5/8 (5.87 mm) flat Phillips (+) head screw S6-0 5 /4" (9.05 mm) thick wood platform 0-4 x 5/6 (7.9 mm) flat Phillips (+) head screw 0- x 5/6 (7.9 mm) flat slotted (-) head screw S /6" (7.9 mm) thick aluminum, phenolic and stainless steel platforms. S all stainless steel platforms NOTE: 800 ml Fernbach Flask Clamp applicable to above chart. NEW BRUNSWICK SCIENTIFIC MODEL G-4 6

14 INSTALLATION CONTROL FOR G-4 All controls are fitted with a spring-mounted lock to prevent vibration from changing the desired temperature and speed. CONTROLS Power On/Off Switch Shaker On/Off Switch Heater On/Off Switch Control Thermostat Safety Thermostat Speed Control Vent (Rear) Speed & Temperature Selector Switch PURPOSE Controls power to unit. Controls power to drive motor. Controls power to temperature control circuitry. Control temperature of unit. Provides protection so maximum desired temperature is not exceeded. Used to set desired shaking speed. Used for mixing of air in chamber. When set to the speed position, digital display indicates speed. When set to the temperature position the digital display will indicate chamber temperature. NEW BRUNSWICK SCIENTIFIC MODEL G-4 7

15 OPERATION. With the Power switch OFF, open the cover and check that the four platform screws are fully tightened before using the apparatus. CAUTION: WEAR PROTECTIVE GLOVES WHEN HANDLING GLASSWARE.. For proper high speed performance, fully load the shaker platform. The Shaker has been designed for precise dynamic balance when the platform is fully loaded with each flask containing 0% by volume of water. If the total number of cultures to be used are less than the platform capacity, install empty flasks in the remaining holders and fill each with water to 0% capacity. For speeds below 400 RPM, the dynamics of the system are less sensitive, and therefore less care need be taken in the loading procedure. Close the cover after loading.. Set both the Power and the Shaker switches ON. Set the speed/temp. selector switch to the speed position. Depress the locking tab on the Speed Control and adjust the Speed Control for the desired shaking speed and release the locking tab. 4. To adjust the temperature of the chamber, proceed as follows: Set the Heater switch ON. 5. Open or close the vent at the rear of the unit as required. NOTE: Both thermostats are calibrated at 7 C and correspond to a dial setting of 7. All other graduations are not relative since the thermostats are non-linear. NEW BRUNSWICK SCIENTIFIC MODEL G-4 8

16 OPERATION 6. For temperatures other than 7 C, both thermostats are rotated to a higher or lower setting. When changing temperature settings, depress the locking tab first. The Safety Thermostat is set slightly higher than the Control Thermostat to provide an over temperature protection. Set the speed/temperature selector switch to the temperature position. Monitor the temperature of the chamber on the digital display and adjust both thermostats accordingly. Under normal conditions, the Control Thermostat Indicator Lamp will cycle on and off at the control setting of the Control Thermostat. If the Safety Thermostat indicator lamp lights, this is an indication that: a. The Control Thermostat is not working or, b. The Safety Thermostat is set below the setting of the Control Thermostat. 7. When the optional Gassing Manifold is ordered with the Shaker, it is installed at the factory. A fitting is supplied on the right side of the Shaker. A short hose is attached and clamped to the fitting for gassing purposes. 8. When the optional Heat Exchanger is used, cold water should be connected to one end of the tubing and the other tubing should be run to a drain line. 9. When turning the Shaker off, first rotate the Speed Control to its minimum speed setting (counter-clockwise) and then set the Shaker, Heater and Power switches OFF. NEW BRUNSWICK SCIENTIFIC MODEL G-4 9

17 MAINTENANCE PREVENTIVE MAINTENANCE Preventive maintenance is performed to keep equipment in proper working order. When periodically performed, preventive maintenance will result in longer life for the equipment and will reduce time lost due to equipment failure. CLEANING Use a clean cloth moistened with water for cleaning the cabinet. Do not use steel wool or other abrasives which will mar the finish. PERIODIC INSPECTION At three month intervals, perform the following checks and inspections with the power switch OFF.. Check the fuses for good contacts.. Remove any accumulated dirt from the unit and underneath the unit.. Check that all controls are tight and operate easily. NEW BRUNSWICK SCIENTIFIC MODEL G-4 0

18 MAINTENANCE CORRECTIVE MAINTENANCE REPLACEMENT OF DRIVE BELT To replace the Drive Belt, proceed as follows:. Set the Power switch OFF and remove the power cord plug from the electrical outlet.. Wearing gloves, remove all flasks from the table.. Tilt the unit on the side panel until the base of the unit is exposed. Remove the base cover by turning each screw 90. Loosen and remove the screws holding the speed sensor assembly away from the pulley. Loosen the bolts on the Motor Mounting Plate and release tension on the Belt. Remove the belt from the Pulleys and install a new one. After installing a new belt, increase tension to the belt by pulling on the Motor Mounting Plate, then tighten the mounting bolts. After installing the belt, replace the speed sensor assembly and tighten the mounting screws to the Motor Mounting Plate. Put the base cover on, upright the unit and connect power. PLATFORM REMOVAL To remove Platform, set the Power switch OFF and raise the cover. Unscrew the 4 retaining screws in the Platform. Make sure the retaining screws are thoroughly tightened when the Platform is replaced. DRIVE MOTOR LUBRICATION The Bearings are sealed on the Motor and do not require lubrication. BEARING LUBRICATION There are ball bearings in the Upper Bearing Housing and 6 ball bearings in the Lower Bearing Housing. The bottom 6 bearings contain grease fittings. The ball bearings should be lubricated every four months, with a high-grade, high temperature, ball bearing grease. DO NOT OVER LUBRICATE. To gain access to the ball bearings, remove the platform from the unit. Power should be OFF when lubrication is required. NEW BRUNSWICK SCIENTIFIC MODEL G-4

19 MAINTENANCE DRIVE MOTOR BRUSH REPLACEMENT The Drive Motor Brushes should be replaced when the brushes are worn to /4 of an inch. The original brush length is 7/8". If the unit operates erratically or not at all, check the brushes. The brushes on the motor can be reached by removing the platform and the protective cover in the front of the chamber. Make sure power is off when working on the unit. BEARING REPLACEMENT To replace the Bearings, proceed as follows:. Remove power from the unit and remove the platform.. Remove the drive belt and pulley from the bearing housing.. Working from the bottom of the unit, remove the 6 bolts which secure the bearing housing to the frame. Carefully remove the housing. 4. Remove the bolts and washers holding the bearings on the upper bearing housing. Carefully lift the upper bearing housing off of the eccentric shafts. The bearings can be tapped out or removed with a bearing puller if secured tightly. 5. On the lower bearing housing, remove all retaining rings and extract the shafts. The bearings can be removed as in Step 4. NOTE: The Upper Bearings on the Lower Bearing Housing must have the seal side of the Bearing facing away from the Housing. 6. Coat the outside mounting surface of the bearing with "Loctite". Replace all bearings, install shafts and retaining rings. Do not use excessive force or scratch the shafts when reassembling. Reassemble the upper bearing housing to the lower bearing housing and secure with the bolts and washers. 7. Reinstall the bearing housing in the shaker as removed. Replace the pulley belt and platform. NEW BRUNSWICK SCIENTIFIC MODEL G-4

20 TABLE - REPLACEMENT PARTS LIST REPLACEMENT PARTS The following table represents parts to be kept on hand to reduce equipment repair time. PART NO. DESCRIPTION QTY/UNIT R-4 V-Belt P Upper Bearing Housing Bearings P Lower Bearing Housing Bearings (Upper) P Lower Bearing Housing Bearings (Lower) M Idler Shaft M Drive Shaft H-8 Retaining Ring (Inside of lower bearing housing) P Retaining Ring (Outside lower bearing housing) EB-50 Motor Brushes M-67 Motor EC-86 Cord Set G77-80 Rectifier Module EI-07 Indicator 5 ET-8 Variac Transformer ES-0 Switch DPST Main Power and Heater ES- Switch DPST Main Power and Heater ET-5 Thermostat P04-08 Resistor 50 Ohms (Blower Motor) Adjustable P Heater Element 06 Ohms 57 Watts EF-00 Fuse 5.0 Amp (00/0V) EF-04 Fuse.0 Amp (00/0V) M Fan Motor P000-0 Fan Blade M06-0 Rod Lid Support M Power Supply P.C. Assembly M0-050 D.V.M./Converter Board Assembly M7-8 Temperature Sensor M0-040 Optical Switch Assy., 0/0V, 50 Hz, Phase EI-4 Indicator 0V P Fuse Amp P Transformer /4 KVA (08/0 Primary, 5V Secondary) NEW BRUNSWICK SCIENTIFIC MODEL G-4

21 TABLE - REPLACEMENT PARTS LIST PART NO. DESCRIPTION QTY/UNIT EF-8 Fuse 6.5 Amp (00/0V) P Fuse.5 Amp (0/40V) P Fuse 0. Amp (00/0V) P Fuse 0. Amp (0/40V) P Fuse.5 Amp (0/40V) P Fuse.0 Amp (0/40V) NOTE: For electrical components, refer to the electrical drawings and bills of material. IMPORTANT: When placing orders for replacement parts or for information on service, kindly furnish the serial number of the equipment which appears on the electrical specifications plate. NEW BRUNSWICK SCIENTIFIC MODEL G-4 4

22 FIGURE NEW BRUNSWICK SCIENTIFIC MODEL G-4 5

23 MAINTENANCE CALIBRATION PROCEDURE. Turn the Main Power switch OFF.. Remove the front panel.. Turn the Main Power switch ON. CONVERTER BOARD CALIBRATION (Figure ). Set the digital display to read Temperature.. Turn the heater switch ON.. Adjust the control thermostat so that a steady state temperature of 7 C is obtained on an accurate reference thermometer, which is placed centrally within the unit. 4. Adjust Pot. R on the converter board so that the digital display indicated 7 C. 5. Turn heater switch OFF. 6. Turn shaker switch OFF. 7. Set the digital display to read Speed. 8. Adjust Pot. R on the converter board so that the digital display indicated Turn the shaker switch ON. 0. Adjust the speed to approx. 500 RPM. When using a Stroboscope:. Adjust R4 on the converter board so that the digital display indicates the speed, as determined with the Stroboscope. When using an Oscilloscope:. Turn the speed switch OFF.. Turn the main power switch OFF. 4. Replace the front panel. NEW BRUNSWICK SCIENTIFIC MODEL G-4 6

24 CLAMP MOUNTING HARDWARE KIT CLAMP MOUNTING HARDWARE KIT HARDWARE FOR 0 ml TO 500 ml CLAMPS NBS Flask Clamps are used on a variety of shaker platforms. Flat head screws of different NBS flask clamps are used on a variety of shaker platforms. Flat head screws of different lengths and thread pitch are used to secure the clamp. The following tables identify the proper screw for your shaker application by reference to the head style. Description Part Number Qty. Application 0-4 x 5/8 (5.87 mm) S6-0 /4" (9.05 mm) thick flat Phillips (+) head screw wood platform 0-4 x 5/6 (7.9 mm) flat Phillips (+) head screw 0- x 5/6 (7.9 mm) flat slotted (-) head screw S6-05 5/6" (7.9 mm) thick aluminum, phenolic and stainless steel platforms. S7-050 all stainless steel platforms HARDWARE FOR LITER TO 6 LITER CLAMPS Description Part Number Qty. Application 0-4 x 5/8 (5.87 mm) flat Phillips (+) head screw S6-0 5 /4" (9.05 mm) thick wood platform 0-4 x 5/6 (7.9 mm) flat Phillips (+) head screw 0- x 5/6 (7.9 mm) flat slotted (-) head screw S /6" (7.9 mm) thick aluminum, phenolic and stainless steel platforms. S all stainless steel platforms NOTE: 800 ml Fernbach Flask Clamp applicable to above chart. NEW BRUNSWICK SCIENTIFIC MODEL G-4 7

25 FIGURE NEW BRUNSWICK SCIENTIFIC MODEL G-4 8

26 FIGURE NEW BRUNSWICK SCIENTIFIC MODEL G-4 9

27 7 6 POWER SUPPLY F L O VAT ARM D MTR 4 LT A J- J- J- J-5 J- J(GND) J(-) J(+5) J(GVD) J(+) TGS MAIN POWER DISC C NO FU.0A TGS HEATER FU.5A TB SAFETY CONTROL TB 5 6 TB TB TB J DVM 4FU 0.A TEMP RECORDER TAS TGS SHAKER J- J- TO CUSTOMER'S POWER SUPPLY J LINE LOAD J- J-4 J-6 J-7 J-0 J-9 CONVERTER J-6 J-4 J-8 J-5 T- /4 KVA POWER LF A KEY LT TB TAS 4LT 5LT A A R TEMP 4TGS SPEED SPEED SENSOR E.5A A MTR TEMP SENSOR 9W-0V HTR LT BLOWER C M L NOTES: 4) UNDERLINING DENOTES NAMEPLATES OR LABELS ON OR NEAR CONTROL DEVICE. 5) NUMBERS IN CIRCLES DENOTE TERMINAL BLOCK NUMBERS. 6) FU REQUIRED FOR COUNTRIES WHERE BOTH SIDES OF THE AC LINE IS ABOVE GROUND-COUNTRIES WITH THE NEUTRAL SIDE OF THE 0 VAC LINE GROUNDED REQUIRES A FUSE IN THE ACTIVE (HOT) LINE ONLY. L L K J H G F E REF.DWG WIRING DIAGRAM M REV DATE DESCRIPTION OF REVISION BY APPV TITLE RELOCATED LF. ECN 956RM ADDED LF. ECN 95 RM JB UNLESS OTHERWISE SPECIFIED NEXT ASSEMBLY DIMENSIONS ARE IN INCHES, TOLERANCES ARE: SCALE FRACTIONS: /64 DECIMALS:.XX -.05.XXX DWG ANGULAR: / ANGULAR: SHT OF NEW BRUNSWICK SCIENTIF CONTROL SCHEMATIC-G4 0V-0-50 HZ SIZE FU WAS.5A ECN# 5 R.M. UPDATED WIRING OF FU ECN# 068 R.M. FU & FU WERE A, FU WAS /A. ADDED 4FU,RELOCATE FU ECN# 8944 R.M. ADDED LABELS ECN# 670 B.H. J.B. NONE DWN CHKD APPVD B.E.H. DATE DATE DATE DRAWING NUMBER J.B J.B REV LTR FIGURE 4 8 MC L DELETED NOTE#7 ECCN-85 R.A.B D REDRAWN ECN# 6590 B.H. J.B. C M L FU SEE NOTE #6 CONTROL SCHEMATIC 0V 50 HZ NEW BRUNSWICK SCIENTIFIC MODEL G-4 0

28 7 6 POWER SUPPLY F L O VAT ARM D MTR 4 LT A J- J- J- J-5 J- J(GND) J(-) J(+5) J(GVD) J(+) TB TB TGS MAIN POWER DISC C NO TGS HEATER FU TB 7 J DVM 4FU 0.A TEMP RECORDER TAS 5 A A TGS SHAKER J- J- TO CUSTOMER'S POWER SUPPLY J J- J-4 J-6 J-7 J-0 J-9 CONVERTER J-6 J-4 J-8 J-5 SEE NOTE #7 KEY TB TAS 4LT 5LT SAFETY CONTROL TEMP 4TGS SPEED SPEED SENSOR LT A MTR TEMP SENSOR 0W-5V HTR BLOWER 6 TB NOTES: 4) UNDERLINING DENOTES NAMEPLATES OR LABELS ON OR NEAR CONTROL DEVICE. 5) NUMBERS IN CIRCLES DENOTE TERMINAL BOARD NUMBERS. 7) FOR 00VAC-50/60 HZ UNITS USE VAT (4) INSTEAD OF TERMINAL VAT (). REF.DWG WIRING DIAGRAM M06-00 FU.0A POWER LT A C M06-00 G G G G F E D C B A REV DATE DESCRIPTION OF REVISION BY APPV TITLE UNLESS OTHERWISE SPECIFIED NEXT ASSEMBLY DIMENSIONS ARE IN INCHES, TOLERANCES ARE: SCALE FRACTIONS: /64 DECIMALS:.XX -.05.XXX DWG ANGULAR: / ANGULAR: UPDATED CONV. & POWER SUPPLY BOARD WIRING ECN# 4 J.P. M.C. NEW BRUNSWICK SCIENTIF CONTROL SCHEMATIC-G4 00V/0V-0-50/60 HZ DWN CHKD APPVD DATE DATE DATE DRAWING NUMBER SHT OF C M06-00 G SIZE DELETED RESISTOR R AND NOTE #6 ECN-85 R.A.B FU WAS.5A ECN# 5 R.M. JB UPDATED WIRING OF FU ECN# 068 R.M. JB DELETE FU. ADDED FU & 4FU ADDED NOTE #7 ECN# 8944 R.M. JB FU WAS 5 AMPS ECN# 6 R.D. J.B. ADDED RECORDER JACK ECN# 54 R.A.B.R.R. R.A.B J.B J.B REV LTR FIGURE 5 8 MC 5A TB CONTROL SCHEMATIC 00/0V 50/60 HZ NEW BRUNSWICK SCIENTIFIC MODEL G-4

29 7 6 POWER SUPPLY F L O VAT ARM D MTR 4 LT A J- J- J- J-5 J- J(GND) J(-) J(+5) J(GVD) J(+) TB TB TGS MAIN POWER DISC C NO TGS HEATER FU 6.5A TB TB 7 J DVM 4FU 0.A TEMP RECORDER TAS 5 A A TGS SHAKER J- J- TO CUSTOMER'S POWER SUPPLY J J- J-4 J-6 J-7 J-0 J-9 CONVERTER J-6 J-4 J-8 J-5 SEE NOTE #7 KEY TB TAS 4LT 5LT SAFETY CONTROL SPEED SENSOR TEMP 4TGS SPEED LT A MTR TEMP SENSOR 440 W-5V HTR BLOWER 6 TB NOTES: 4) UNDERLINING DENOTES NAMEPLATES OR LABELS ON OR NEAR CONTROL DEVICE. 5) NUMBERS IN CIRCLES DENOTE TERMINAL BOARD NUMBERS. 7) FOR 00VAC-50/60 HZ UNITS USE VAT (4) INSTEAD OF TERMINAL VAT (). REF.DWG WIRING DIAGRAM M FU.0A POWER LT A C M C C B A REV DATE DESCRIPTION OF REVISION BY APPV TITLE 5-9 UNLESS OTHERWISE SPECIFIED NEXT ASSEMBLY DIMENSIONS ARE IN INCHES, TOLERANCES ARE: SCALE FRACTIONS: /64 DECIMALS:.XX -.05.XXX DWG ANGULAR: / ANGULAR: DELETED NOTE#6 AND RESISTOR R ECN-85 R.A.B NEW BRUNSWICK SCIENTIF CONTROL SCHEMATIC-G4 HI TEMP. 00V/0V-0-50/60 HZ DWN CHKD APPVD DATE DATE DATE DRAWING NUMBER SHT OF C M C SIZE FU WAS.5A ECN# 5 R.M. JB -4 9 RELEASED G.L.J.G.L.J G.L.J G.L.J G.L.J REV LTR FIGURE 6 8 MC CONTROL SCHEMATIC - HI TEMPERATURE 00V/0V - 50/60 HZ NEW BRUNSWICK SCIENTIFIC MODEL G-4

30 7 6 POWER SUPPLY F L O VAT ARM D MTR 4 LT A J- J- J- J-5 J- J(GND) J(-) J(+5) J(GVD) J(+) FU.0A TGS HEATER J DVM 4FU 0.A TEMP RECORDER TAS SAFETY CONTROL TB 5 6 TB TB TB TGS SHAKER J- J J J- J-4 J-6 J-7 J-0 J-9 CONVERTER J-6 J-4 J-8 J-5 T- /4 KVA POWER A KEY LT TAS 4LT 5LT A A R TEMP 4TGS SPEED SPEED SENSOR A MTR TEMP SENSOR HTR LT BLOWER NOTES: 4) UNDERLINING DENOTES NAMEPLATES OR LABELS ON OR NEAR CONTROL DEVICE. 5) NUMBERS IN CIRCLES DENOTE TERMINAL BLOCK NUMBERS. 6) FU REQUIRED FOR COUNTRIES WHERE BOTH SIDES OF THE AC LINE IS ABOVE GROUND-COUNTRIES WITH THE NEUTRAL SIDE OF THE 0 VAC LINE GROUNDED REQUIRES A FUSE IN THE ACTIVE (HOT) LINE ONLY. REF.DWG WIRING DIAGRAM M TGS C MAIN POWER DISC NO FU.5A TB TO CUSTOMER'S POWER SUPPLY LINE LOAD LF 4 TB FU.5A SEE NOTE #6 C M E E E D C B A REV DATE DESCRIPTION OF REVISION BY APPV TITLE RELOCATED LF. ECN 956RM JB ADDED LF. ECN 95 RM JB 5-9 FU WAS.5A. ECN 8 RM JB -6 9 RELEASED G.L.J G.L.J UNLESS OTHERWISE SPECIFIED NEXT ASSEMBLY DIMENSIONS ARE IN INCHES, TOLERANCES ARE: SCALE FRACTIONS: /64 DECIMALS:.XX -.05.XXX DWG ANGULAR: / ANGULAR: SHT OF NEW BRUNSWICK SCIENTIF CONTROL SCHEMATIC G4 HI TEMP. 70C 0V-40V- SIZE NONE DWN CHKD APPVD G.L.J DATE DATE DATE -6-9 DRAWING NUMBER G.L.J -6-9 G.L.J -6-9 C M E REV LTR FIGURE 7 8 MC E DELETE NOTE#7 ECN-85 R.A.B CONTROL SCHEMATIC - HI TEMPERATURE 0V/40V 50 HZ NEW BRUNSWICK SCIENTIFIC MODEL G-4

New Brunswick Products. Operating Manual M Revision D+

New Brunswick Products. Operating Manual M Revision D+ New Brunswick Products Operating Manual M1193-1055 Revision D+ The enclosed Operating Manual was originally produced by the New Brunswick Scientific Company, Inc. About Eppendorf Eppendorf is a biotech

More information

New Brunswick Biological Shakers Excella E-25/25R. Operating Manual M Revision D

New Brunswick Biological Shakers Excella E-25/25R. Operating Manual M Revision D 1 New Brunswick Biological Shakers Excella E-25/25R Operating Manual M1353-0050 Revision D 2 COPYRIGHT: Copyright 2011 New Brunswick Scientific Co., Inc., USA. No part of this publication may be reproduced

More information

New Brunswick Products. Operating Manual M Revision D+

New Brunswick Products. Operating Manual M Revision D+ New Brunswick Products Operating Manual M1194-0051 Revision D+ The enclosed Operating Manual was originally produced by the New Brunswick Scientific Company, Inc. About Eppendorf Eppendorf is a biotech

More information

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345 Part No. 39406 DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345 SAFETY PRECAUTIONS 2 INSTALLATION INSTRUCTIONS Inspection of Shipment: Unpack all cartons and check thoroughly for any

More information

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496 Part No. 39177 Countertop B.I.B. Butter Dispenser Instruction Manual Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS Installation Instructions Countertop B.I.B. Checking Shipment Unpack all cartons and

More information

Digital Incubator Shaker. MANUAL NO: M Revision V August 5, 2002

Digital Incubator Shaker. MANUAL NO: M Revision V August 5, 2002 Digital Incubator Shaker MANUAL NO: M1192-0050 Revision V August 5, 2002 NEW BRUNSWICK SCIENTIFIC CO., INC. BOX 4005 44 TALMADGE ROAD EDISON, NJ 08818-4005 Telephone: 1-732-287-1200 1-800-631-5417 Fax:

More information

New Brunswick Products. Operating Manual M Revision N+

New Brunswick Products. Operating Manual M Revision N+ New Brunswick Products Operating Manual M1233-0054 Revision N+ The enclosed Operating Manual was originally produced by the New Brunswick Scientific Company, Inc. About Eppendorf Eppendorf is a biotech

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves

More information

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008 ROLLER GRILL Instruction Manual Model #8223, 8224, 8225 Part No. 88189 Revised:March 2008 Safety Precautions Models #8223, 2 #8224, #8225 FORWARD This manual covers the model # 8223, # 8223, 8225 ROLLER

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

PARTS & SERVICE MANUAL

PARTS & SERVICE MANUAL PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old

More information

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and AVTM220003 Rev. B January 2003 Instruction Manual AVTM220003 for DC µa Strip Chart Recorder Catalog Nos. 220003 and 220003-47 PO Box 9007 Valley Forge, PA 19485-1007 U.S.A. 610-676-8500 Shipping Address:

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

TABLE OF CONTENTS. Ram Assembly

TABLE OF CONTENTS. Ram Assembly TABLE OF CONTENTS DUC Cover------------------------------------------------------------------------------------ 00 Table of Contents----------------------------------------------------------------------------

More information

Cincinnati, OH USA

Cincinnati, OH USA Astro Pop Warmer Instruction Manual Model #2002 Part No. 61987 Revised July 2000 Cincinnati, OH 45241-4807 USA e-mail: goldme19@eos.net www.gmpopcorn.com SAFETY PRECAUTIONS INTRODUCTION Your new #2002

More information

(For serial numbers before w/ analog control)

(For serial numbers before w/ analog control) SEQUENCE OF OPERATIONS (For serial numbers before 2038616 w/ analog control) MODEL 1154-000-EA NAT. GAS 230 VAC 50 HZ. 1 PHASE MODEL 1155-000-EA LP GAS 230 VAC 50 HZ. 1 PHASE POWER SUPPLY Electrical power

More information

Export Bucket Pump Instruction Manual Models: 2114XE & 2114XD

Export Bucket Pump Instruction Manual Models: 2114XE & 2114XD Part No. 79064XE Revised: August 2006 Export Bucket Pump Instruction Manual Cincinnati, OH 45241 USA SAFETY PRECAUTIONS INTRODUCTION This manual provides instruction for installation and operation of the

More information

Digital Tier Shaker. MANUAL NO: M Revision N May 23, 2002

Digital Tier Shaker. MANUAL NO: M Revision N May 23, 2002 Digital Tier Shaker MANUAL NO: M1196-0050 Revision N May 23, 2002 NEW BRUNSWICK SCIENTIFIC CO., INC. BOX 4005 44 TALMADGE ROAD EDISON, NJ 08818-4005 Telephone: 1-732-287-1200 1-800-631-5417 Fax: 732-287-4222

More information

GROB 4V-24 Parts. GrobBandSaw.com

GROB 4V-24 Parts. GrobBandSaw.com GROB 4V- Parts GrobBandSaw.com 888-550-3116 18 19 20 21 22 5/16-18x1/2 Hex Head Cap Screw ( 14 ) 34 35 36 37 38 39 40 39 41 42 43 44 45 46 17 16 3/8-16x3/4 Hex Head Cap Screw ( 2 ) 31 30 15 5/16-18x1 Hex

More information

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge 200 Shadylane Drive Philipsburg, PA 16866 Phone: (814) 342-6205 Fax: (814) 342-4510 www.druckerdiagnostics.com Service Manual Model 642E Centrifuge MODEL 642E SERVICE MANUAL REV: Original Issue 1 CONTENTS

More information

k ual I24/24R Benchtop Incubator Shaker N) manual New Brunswick I24/24R Benchtop Incubator Shaker Operating manual

k ual I24/24R Benchtop Incubator Shaker N) manual New Brunswick I24/24R Benchtop Incubator Shaker Operating manual k ual I24/24R Benchtop Incubator Shaker N) manual New Brunswick I24/24R Benchtop Incubator Shaker Operating manual Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Model G14SD Vapor Management System

Model G14SD Vapor Management System Instruction Manual Model G14SD Vapor Management System (For Models: DSD and SSD 110/115v) Manufactured in USA for Medivators Reprocessing Systems by: PCI Medical Inc. 12 Bridge Street, PO Box 188 Deep

More information

Installation & Operation Manual Chef Base

Installation & Operation Manual Chef Base Installation & Operation Manual Chef Base Please read this manual completely before installing or operating this unit! BACB53 BACB53M BACB71 BACB71M BACB74 BACB74M BACB83 BACB83M BACB86 BACB86M BACB96

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

Automatic Butter Dispenser Instruction Manual Model #2395NS

Automatic Butter Dispenser Instruction Manual Model #2395NS Automatic Butter Dispenser Instruction Manual Part No. 39642 Revised: July 2006 Cincinnati, OH 45241 USA Safety Precautions Automatic Butter Dispenser 2 INTRODUCTION Automatic Butter Dispenser This manual

More information

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-001N

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-001N Easy Picker Golf Products, Inc. 415 Leonard Blvd. N., Lehigh Acres, FL 33971 PH: 239-368-6600 FAX: 239-369-1579 Service: 800-982-4653 SALES: 800-641-4653 www.easypicker.com salesdept@easypicker.com INSTALLATION

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVEN MODEL 1100-000-A SERIES (SN 2038615 & BELOW) SERVICE MANUAL Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United

More information

SEC. SEC America, LLC. Model 680 CE, DC-DC Converter Owner's Manual

SEC. SEC America, LLC. Model 680 CE, DC-DC Converter Owner's Manual SEC SEC America, LLC Model 680 CE, DC-DC Converter Owner's Manual April 15, 2010 TABLE OF CONTENTS page I Introduction 1 II Installation 1 2.1 Mounting 1 2.2 Connections 1 2.3 Methods of Converter Activation

More information

ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL

ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL This document includes: Warranty Specifications Wiring Diagram Operating Instructions Cleaning Instructions Parts List P/N: 11B741 Model UW1

More information

DCC-3000 Climate Control for Vintage Air GEN-IV systems

DCC-3000 Climate Control for Vintage Air GEN-IV systems INSTALLATION AND OPERATOR S MANUAL FOR DCC-3000 Climate Control for Vintage Air GEN-IV systems PARTS INCLUDED WITH THIS SYSTEM Vent sensor housings: 2 1 / 2 housings (x2) 2 housings (x2) Installation/operator

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER: 21-8203 2003-2005 DODGE RAM 1500 Pickup V8-5.7L C.A.R.B. E.O. # D-670 2003-2005 DODGE RAM 2500 Pickup V8-5.7L C.A.R.B.

More information

TS , -850 Series TS , -850 Series TS-57031, TS

TS , -850 Series TS , -850 Series TS-57031, TS TS-5711-770, -850 Series TS-57011-770, -850 Series TS-57031, TS-57031-850 Electronic Room Temperature Sensors General Instructions Application These sensors provide electronic sensing of room temperature

More information

Model 700 Microarray Oven

Model 700 Microarray Oven www.scigene.com Model 700 Microarray Oven USER MANUAL Cat. #1070-00-1, 1070-00-2 FOR RESEARCH USE ONLY Not for Use in Diagnostic Procedures SciGene 306 Potrero Ave, Sunnyvale, CA 94085 USA 408-733-7337

More information

Dispenser & Warmer RIC-1909 RIC-1909EXP

Dispenser & Warmer RIC-1909 RIC-1909EXP Dispenser & Warmer RIC-1909 RIC-1909EXP Safety Precautions CAUTION This equipment is designed and sold for commercial use only. This equipment is not to be used by the consumer in home use. Do not allow

More information

Model 616 Rotating Disk Electrode Instruction Manual

Model 616 Rotating Disk Electrode Instruction Manual Model 616 Rotating Disk Electrode Instruction Manual 219303 C / 1202 Printed in USA Advanced Measurement Technology, Inc. a/k/a Princeton Applied Research, a subsidiary of AMETEK, Inc. WARRANTY Princeton

More information

INSTALLATION INSTRUCTIONS PART NUMBER:

INSTALLATION INSTRUCTIONS PART NUMBER: Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER: 21-8205 2003-2004 DODGE RAM 1500 Pickup V8-4.7L C.A.R.B. E.O. # D-392-29 * NOTE: Legal in California only for racing

More information

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection: PL900 ILLUMINATOR A PRODUCT OF DOLAN-JENNER INDUSTRIES Setup Voltage Selection: Operation Manual Read and review the instructions on the label covering the power entry module and the instructions in this

More information

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual 200 Shadylane Drive Philipsburg, PA 16866 Phone: (814) 342-6205 Fax: (814) 342-4510 www.druckerdiagnostics.com Service Manual Model 755VES Centrifuge MODEL 755VES SERVICE MANUAL REV: A 1 CONTENTS 1 PREFACE...

More information

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls P-269-89-0408 Installation Installation & Operating Instructions Contents Introduction........................... 2 Specifications.........................

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

GF1900 SULFURYL FLUORIDE MONITOR

GF1900 SULFURYL FLUORIDE MONITOR GF1900 SULFURYL FLUORIDE MONITOR Revision: H Release Date: 12/12/2018 Page 1 of 20 This page intentionally left blank Revision: H Release Date: 12/12/2018 Page 2 of 20 TABLE OF CONTENTS INTRODUCTION......

More information

INSTALLATION AND MAINTENANCE MANUAL

INSTALLATION AND MAINTENANCE MANUAL TYPE 2 PTO INSTALLATION AND MAINTENANCE MANUAL P.O. Box 8148 Wichita Falls, Texas 76307 1600 Fisher Rd. Wichita Falls, Texas 76305 Phone: (940) 7611971 Fax: (940) 7611989 www.wptpower.com email: info@wptpower.com

More information

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual Copyright Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior permission

More information

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and CO 2 Pressuring Assemblies #170-00-5: (115 V) #170-01-5: (230 V) Instruction Manual Updated 11/5/2014 Ver. 2.3 OFI Testing

More information

PARTS LIST GAS TILTING SKILLETS MODELS: GLTS-30 GLTS-40

PARTS LIST GAS TILTING SKILLETS MODELS: GLTS-30 GLTS-40 PARTS LIST GAS TILTING SKILLETS MODELS: CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324 PRINTED IN CANADA PART NUMBER

More information

Atmospheric Consistometer # (115V) # (220V) Instruction Manual. Updated 1/25/2018 Ver. 6.0

Atmospheric Consistometer # (115V) # (220V) Instruction Manual. Updated 1/25/2018 Ver. 6.0 Atmospheric Consistometer #120-75 (115V) #120-75-1 (220V) Instruction Manual Updated 1/25/2018 Ver. 6.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300

More information

MODEL SCA Installation and Operation Manual Important:

MODEL SCA Installation and Operation Manual Important: MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

OPERATING INSTRUCTIONS FINISHER 4300

OPERATING INSTRUCTIONS FINISHER 4300 OPERATING INSTRUCTIONS FINISHER 4300 Model No. BA-FS43 Banner American Products, Inc. Temecula, CA Table of Contents I. For Your Safety... 2 II. Electrical Safeguards... 2-3 III. Specifications... 3 IV.

More information

Owner s Manual TC-515 with Reversed Hoist, Sub-Frame, Deck, & Hitch Mount

Owner s Manual TC-515 with Reversed Hoist, Sub-Frame, Deck, & Hitch Mount Proudly built in the USA Owner s Manual TC-55 with Reversed Hoist, Sub-Frame, Deck, & Hitch Mount TruckCraft Corporation Chambersburg, PA -800-755-87 Copyright c 0 www.truckcraft.com TruckCraft Corporation

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1433-000-E, 1434-000-E, 1456, 1457 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804

More information

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised: XPS-ProFeed Shuttle SERVICE MANUAL Revised: 9-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY

More information

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting Electrical wiring and connections should be

More information

Parts & Service Information K810054C PRODUCT IMPROVEMENT

Parts & Service Information K810054C PRODUCT IMPROVEMENT Parts & Service Information K810054C Disclaimer: This bulletin release is for informational purposes only and is not factory authorization for warranty repairs or warranty claim submission. PRODUCT IMPROVEMENT

More information

Solstice Electric Fryers SE Series Service Manual

Solstice Electric Fryers SE Series Service Manual Solstice Electric Fryers SE Series Service Manual L22-330 R1 (10/12) Notice In the event of problems or questions about your order, contact the Pitco Frialator factory at (603) 225-6684. In the event of

More information

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD ----------------------------------------------------------------We Make Clean Air----------------------------------------------------------------

More information

advanced FLOW engineering Instruction Manual P/N: Make: Dodge Model: 2500 / 3500 Year: Engine: I-6 5.9L (td)

advanced FLOW engineering Instruction Manual P/N: Make: Dodge Model: 2500 / 3500 Year: Engine: I-6 5.9L (td) advanced FLOW engineering Instruction Manual P/N: 42-22011 DFS780 PRO Make: Dodge Model: 2500 / 3500 Year: 1998.5-2002 Engine: I-6 5.9L (td) 1 Label Qty. Description Part Number A 1 Fuel Manifold Assembly

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * FunPop Assembly Manual Model # 2649CR Part No. 59406CR Revised: October 2004 Cincinnati, OH 45241-4807 USA INSTALLATION INSTRUCTIONS Checking Shipment Unpack carton and check thoroughly

More information

SERVICE MANUAL (DOMESTIC)

SERVICE MANUAL (DOMESTIC) SERVICE MANUAL (DOMESTIC) IMPINGER CONVEYOR OVENS IMPINGER II - ADVANTAGE SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800)

More information

Operating and Maintenance Instructions

Operating and Maintenance Instructions HIGH SPEED ALLOY GRINDER MODEL AG05 Operating and Maintenance Instructions Sales, Service, and Technical Assistance Call Toll Free 800 / 654-4519 Ray Foster Dental Equipment 5421 Commercial Dr, Huntington

More information

Operations and Service Manual. X30208 Load Bank

Operations and Service Manual. X30208 Load Bank Operations and Service Manual Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a)... 4 3) Receiving... 5 4) Safety... 5 a) Ground

More information

MityFlex Peristaltic Pump

MityFlex Peristaltic Pump WORLD PRECISION INSTRUMENTS Instrumenting scientific ideas INSTRUCTION MANUAL MityFlex Peristaltic Pump Serial No. www.wpiinc.com 0536 MityFlex CONTENTS ABOUT THIS MANUAL... INTRODUCTION... SPECIFICATIONS...

More information

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised: XPS-ProFeed Shuttle SERVICE MANUAL Revised: 1-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY

More information

Bag-In-A-Box Oil Pump System

Bag-In-A-Box Oil Pump System Bag-In-A-Box Oil Pump System Part No. 79285 Revised February 2000 INSTRUCTION MANUAL MODEL #2257 AND MODEL #2257H Cincinnati, OH 45241-4807 USA e-mail: goldme19@eos.net www.gmpopcorn.com SAFETY PRECAUTIONS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS #52180C3 Corvette Radiator & Fan Kits #52181C3 Fits 1968-1972 Fits 1970-1982 Chevrolet Corvette C3 Note: Manual transmission preferred; automatic transmission requires a remote cooler. (pt. #4116C3 available)

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A E355088 READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the instructions in this manual

More information

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER Table of Contents Page Tools Needed (A) 3 Replacement

More information

P/N Wheeler. user manual

P/N Wheeler. user manual P/N 35000068 Wheeler user manual 1998, 1999 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from

More information

P/N Deluxe Model 1200T WITH THERMOSTAT P/N Standard Model 3550 WITHOUT THERMOSTAT

P/N Deluxe Model 1200T WITH THERMOSTAT P/N Standard Model 3550 WITHOUT THERMOSTAT Read and Save These Instructions From MaxxAir Vent Corporation TURBO/ MaxxAir the leader in RV ventilation 215120 CSA approved. Complies with UL507 TURBO/MAXX 12 Volt Installation Instructions P/N 00-965001

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * FunPop CART Assembly Manual Model # 2689 CARTS Part No. 59411 Revised: FEB 2009 Cincinnati, OH 45241-4807 USA INSTALLATION INSTRUCTIONS Checking Shipment Unpack all cartons and check

More information

BL7000 SYSTEM OPERATING MANUAL

BL7000 SYSTEM OPERATING MANUAL BL7000 SYSTEM OPERATING MANUAL REV 2.0 208 / 230V COPYRIGHT 1995 Xenotech, Inc. PAGE 1 POWER INPUT CONNECTOR WIRING INSTRUCTIONS THE INPUT POWER REQUIREMENTS FOR A 7 KW POWER SUPPLY ARE AS FOLLOWS. VOLTAGE

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev Manual Part #: M-3022 Feeder AF371 Operations Rev. 3-16-04 1 RENA AF371 Feeder YOUR RENA AF371 IS DISTRIBUTED BY RENA SYSTEMS INC. SERVICE AND SUPPORT FOR THIS PRODUCT IS PROVIDED BY YOUR RENA DEALER.

More information

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO. INDEX 1. GENERAL SPECIFICATION AND DRAWING 804000-03... 2 2. ASSEMBLY INSTRUCTIONS... 5 3. OPERATING INSTRUCTIONS... 6 4. MAINTENANCE INSTRUCTIONS... 7 5. CERTIFICATE OF CAPACITY LOAD TEST AND OVERLOAD...

More information

Ford C4 and C6 Floor Mount Automatic Transmission Shifter Installation Instructions

Ford C4 and C6 Floor Mount Automatic Transmission Shifter Installation Instructions Ford C4 and C6 Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Ford C4 and C6 Mount

More information

FlexChem Model 404 Rotating Oven

FlexChem Model 404 Rotating Oven www.scigene.com FlexChem Model 404 Rotating Oven USER MANUAL Cat. #1052-20-1, 1052-20-2, 1052-22-1 & 1052-22-2 FOR RESEARCH USE ONLY Not for Use in Diagnostic Procedures SciGene 306 Potrero Ave, Sunnyvale,

More information

I N ST R UC T I ON MODEL 5614 MEAT SAW MODEL ML (Starting Serial Number ) FORM Rev. A (11-95) MEAT SAWS

I N ST R UC T I ON MODEL 5614 MEAT SAW MODEL ML (Starting Serial Number ) FORM Rev. A (11-95) MEAT SAWS I N ST R UC MEAT SAWS T I ON S MODEL 5614 MEAT SAW MODEL 5614 ML-19553 (Starting Serial Number 27-128-712) EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO 45374-0001 FORM 16992 Rev. A (11-95) Installation,

More information

OLYMPIAN MODEL 740 Operation and Service Manual

OLYMPIAN MODEL 740 Operation and Service Manual OLYMPIAN MODEL 740 Operation and Service Manual P/N 133911-102 FCI MANUAL P/N 133865-001 Data herein has been verified and validated and believed adequate for the intended use. If the machine or procedures

More information

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL SRM00046, should be read thoroughly prior to pump installation, operation or maintenance. Manual No. SRM00095

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Part #469003 Model Vektor -H Installation Operation and Maintenance Manual for Vektor-H Laboratory Exhaust System Receiving Greenheck model Vektor-H fans are thoroughly

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended

More information

AUTOMATIC FOODSERVICE EQUIPMENT. AUTOMATIC ELECTRIC BROILER MODELS 824E & 850E and 624E & 650E. B-Series Broiler OWNER S MANUAL

AUTOMATIC FOODSERVICE EQUIPMENT. AUTOMATIC ELECTRIC BROILER MODELS 824E & 850E and 624E & 650E. B-Series Broiler OWNER S MANUAL AUTOMATIC FOODSERVICE EQUIPMENT AUTOMATIC ELECTRIC BROILER MODELS 824E & 850E and 624E & 650E B-Series Broiler OWNER S MANUAL FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or

More information

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting Electrical wiring and connections should be done

More information

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and N 2 # : (115 V) # : (230 V) Instruction Manual

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and N 2 # : (115 V) # : (230 V) Instruction Manual HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and N 2 Pressuring Manifold #170-00-2: (115 V) #170-01-2: (230 V) Instruction Manual Updated 7/31/2017 Ver. 3.0 OFI Testing Equipment,

More information

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Revision 012211 Table of Contents Basic Conveyor Features 3 Getting Started 4 Setting Up the Incline Conveyor 5 Belt Removal

More information

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4 Part No. 89784 Revised: December 2005 FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS INSTALLATION INSTRUCTIONS

More information

Rheometer Calibration Fixture Instruction Manual Model 280 & 286

Rheometer Calibration Fixture Instruction Manual Model 280 & 286 Rheometer Calibration Fixture Instruction Manual Model 280 & 286 Instruction Manual Part No. 204210 Revision B Copyright 2009 Fann Instrument Company Houston, Texas, U.S.A. All rights reserved. No part

More information

ACE Variable Frequency Drive System

ACE Variable Frequency Drive System ACE Variable Frequency Drive System Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1690 BLOWER COOLING INTAKE SHROUDS BLOWER FUSE BLOCK TEMPERATURE CONTROLLER TRANSFORMER

More information

INFINITY-1 HALOGEN LIGHT BAR INSTALLATION MANUAL 7000 SERIES

INFINITY-1 HALOGEN LIGHT BAR INSTALLATION MANUAL 7000 SERIES INFINITY-1 HALOGEN LIGHT BAR INSTALLATION MANUAL 7000 SERIES Your purchase of a Wolo warning light is the perfect choice to compliment your vehicle. Wolo s warning lights are manufactured with the finest

More information

Kit Part Number:

Kit Part Number: Equipped with AEM DRYFLOW Filter No oil required! Kit Part Number: 21-8203 2003-2005 Dodge Ram 5.7L V8 CARB EO # D-392-28 2005 Dodge Powerwagon Hemi CARB EO # D-392-28 Brute Force Intake Systems that are

More information

INFINITY-3 STROBE LED BAR INSTALLATION MANUAL 7700 SERIES

INFINITY-3 STROBE LED BAR INSTALLATION MANUAL 7700 SERIES INFINITY-3 STROBE LED BAR INSTALLATION MANUAL 7700 SERIES Your purchase of a Wolo warning light is the perfect choice to compliment your vehicle. Wolo s warning lights are manufactured with the finest

More information

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)

More information

Little Buddy II Conveyor Dryer with built in Heat Control

Little Buddy II Conveyor Dryer with built in Heat Control Little Buddy II Conveyor Dryer with built in Heat Control 18 wide by 5 long conveyor dryer Document # 16-437 Rev: G Assembly and Operating Instructions Please review all of these instructions prior to

More information

Installation and Operation Guide October 2010

Installation and Operation Guide October 2010 1-800-846-9659 www.equalizersystems.com Hydraulic Trailer Jack Installation and Operation Guide October 2010 Hydraulic Trailer Jack AJ Dual Leg General Description Dual leg trailer jack Lifting capacity:

More information

SAM S CLUB POPPER UniMaxx Kettle Popcorn Machine Instruction Manual Model #2085CL

SAM S CLUB POPPER UniMaxx Kettle Popcorn Machine Instruction Manual Model #2085CL SAM S CLUB POPPER UniMaxx Kettle Popcorn Machine Instruction Manual Model #2085CL Part No. 49388 Revised: March 2009 Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS 2 Model #2085CL UniMaxx INSTALLATION

More information

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: 1500 EcoDiesel Year: Engine: V-6 3.0L (td)

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: 1500 EcoDiesel Year: Engine: V-6 3.0L (td) advanced FLOW engineering Instruction Manual P/N: 42-22041 DFS780 PRO Make: RAM Model: 1500 EcoDiesel Year: 2014-2016 Engine: V-6 3.0L (td) 1 Label Qty. Description Part Number A 1 Fuel Manifold Assembly

More information

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control Boston Gear Ratiotrol DC Motor Speed Control P-3049-BG Doc. No. 83721 Installation and Operation RG1 and RG2 Models 1/6-1 HP a division of Altra Industrial Motion Contents General Information.....................

More information