Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector

Size: px
Start display at page:

Download "Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector"

Transcription

1 Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector ZILA GmbH Neuer Friedberg Suhl Tel.: +49 (0) Fax: +49 (0) Web: info@zila.de

2 Table of contents 1. Scope of Delivery Product description Product features Measuring Range Functions Technical data Operating- and ambient conditions LED bar graph Internal LED digit LED CO2 display Relais LED Standards and Guidelines General safety instructions Mounting and Commissioning Installation position Mounting options Wall- and surface mounting tabletop unit with power supply Electrical connection Connection of actuating elements (examples) VDC ventilation device VDC electric window opener Ventilation devices with heat recovery Maintenance Support Scope of Delivery Indoor Air Quality Guard LGW-13 Mounting material for wall-mounting 24V power supply (optional) 2. Product description The LGW-13 is a versatile CO2 detector. The device has an optical (LED) and acoustic warning signal output (horn). Furthermore, a switching function for common 24 Volt actuators is integrated for use in industrial and domestic applications. The CO2 sensor is integrated in a compact housing made of white polycarbonate (IP 20). The Sensor is based on the optical measurement principle "NDIR" (nondispersive infrared absorption measurement).the device is available in various measuring ranges from Vol% available. The LGW-13 has an integrated function monitoring and is maintenance-free. 3. Product features 3.1. Measuring Range The device measures the CO2 concentration in the ambient air in the range of ppm (Standard). Other measuring ranges up 1,0vol% are available on request Functions used as a CO2 sensor with 0-10V and 4-20mA signal output Suitable as a tabletop unit with a power supply or for wall and surface mounting Air quality traffic light with 10 LEDs CO2 limit dependent switching function for 24 volt devices Integrated alarm horn with 2 volume levels 3.3. Technical data Dimension: (LxWxH): 120x80x35mm Further technical specifications can be found in the product-specific data sheet on our website Operating- and ambient conditions Operating temperature: C Storage temperature: C Relative humidity: % (nicht kondensierend) Air pressure: hpa 3.5. LED bar graph Internal LED The LED in the top ventilation slots indicates the status of the device and the internal monitoring function. The monitoring function operates when the device is turned on. If the LED is red, the device is working properly. If an error occurs, the LED is off digit LED CO2 display The 10-digit display in the standard variant shows the CO2 concentration in the range of ppm in 10 individual steps with 300ppm each. With increasing CO2 concentration, more LEDs permanently turn on from left to right. When reducing the CO2 concentration in accordance with the above steps, the corresponding LEDs turn off. Handbuch Version: DE_1606_TOLI_LGW13 2

3 Relays LED The LED on the left side above the 10-digit display indicates properly connected actuators and the switching state. If the CO2 limit is exceeded and the switching relay is triggered, the LED lights up yellow Standards and Guidelines Der Indoor Air Quality Guard LGW-13 complies with the following European standards and guidelines: 2014/30/EU (EMC Directive) DIN EN : DIN EN : You can mount the device on a wall in a few steps. Note: The following pictures were provided by the manufacturer of the housing and illustrate the mounting of the housing. Even though the actual device deviates from this image, then the procedure does not change during mounting. Step 1: Loosen the lower housing of the device from the cover by opening the holder. 4. General safety instructions Read safety instructions carefully Keep the instruction Mounting, commissioning and electrical connection of the LGW-13 without power supply may only be done by experts Repairs may only be done by experts The mentioned international protection marking applies only when mounting position and cable connection are correct Only operate the device at a given voltage Changes and modifications to the device are forbidden and releases the ZILA GmbH of any guarantee and liability Step 2: Place the bottom case as straight as possible to the wall in order to obtain a drilling template. Drill the holes. 5. Mounting and Commissioning 5.1. Installation position For an optimal indoor air quality with the LGW-13 a mounting height "at eye level" is recommended depending on the application. This means that the seat height of the people in rooms in offices with sedentary activities is crucial for the mounting height. The proper mounting position is horizontally Mounting options Wall- and surface mounting Step 3: Mount the bottom cover with the supplied mounting materials on the wall. Caution: When mounting on the surface, the electrical wires must be fitted through the hole in the middle of the bottom case before firmly mounting the base plate on the wall. Handbuch Version: DE_1606_TOLI_LGW13 3

4 Connect the electric wires according to the circuit diagrams. section commissioning or connection of actuators 5.3. tabletop unit with power supply Insofar as a power supply is in the delivery, connect the power supply via the AC adapter jack on the left side wall of the upper housing cover with the device. 6. Electrical connection The upper section of the circuit board is provided for the electrical connection of peripherals such as 24-volt fans. Ventilation elements are connected via the terminals shown below. Step 4: Take the upper part of device and put it into the holder of the wall-mounted base plate. Close the device by pushing the top part. The LGW-13 is completely assembled when it snaps into the cradle. Seen on the screw Caution: electrical connection exemplary! For detailed information please refer to the The type of signal output from the sensor are picked up via the terminals X4, X5, X6 according to the next picture. The terminal X1 is the power supply, as far as the device is not powered via the power adapter. Handbuch Version: DE_1606_TOLI_LGW13 4

5 Ventilator configuration: JP1 and JP2 closed Ventilator-Connect on X3-1 and X3-3 Seen on the screw The jumpers are located on the circuit board next to the PINs, which are inserted into the terminal on the base plate during the closing of the housing VDC electric window opener The relay of the LGW-13 switches the applied supply voltage (+ 24VDC) of JP1 and the ground GND of JP2 alternately to the voltage input oft he window opener. 7. Connection of actuating elements (examples) VDC ventilation device Window opener configuration: JP1 and JP2 closed FOE-Connect on X2-1 and X Ventilation devices with heat recovery The relay of the LGW-13 switches as a potential-free contact with a ventilation device with heat recovery. This ventilator normally consists of a supply fan and an exhaust fan as well as an own control for the ventilation stages. Optionally, these fans have a connection for an external CO2 switch. In this way, the ventilation unit is connected with the Indoor Air Quality Guard LGW-13. Handbuch Version: DE_1606_TOLI_LGW13 5

6 Ventilation device with heat recovery Configuration for heat recovery: JP1 and JP2 open WRG-Connect on X2-1 and X Maintenance The Indoor Air Quality Guard LGW-13 is maintenance free, thanks to NDIR technology. According to the application, a regular calibration of the device is recommened. 9. Support Telephone: +49 (0) support@zila.de ZILA GmbH Neuer Friedberg Suhl Tel.: +49 (0) Fax: +49 (0) Web: info@zila.de Handbuch Version: DE_1606_TOLI_LGW13 6

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting RCD 010 THD Oct.16 Features Carbon Dioxide (CO2) output 0-10 Vdc Humidity (rh) output 0-10 Vdc Temperature

More information

Condensation monitor

Condensation monitor QXA2101 QXA2100 Condensation monitor QXA2100 QXA2101 Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power. Can also be used with extension module AQX2000

More information

EGQ 212: Duct transducer, CO 2 and temperature

EGQ 212: Duct transducer, CO 2 and temperature Product data sheet 7.0 EGQ : Duct transducer, CO and temperature How energy efficiency is improved Measuring the CO concentration and temperature for energy-efficient, demand-controlled regulation of the

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional

More information

Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional

More information

VA-7450 Series. Electric Valve Actuators

VA-7450 Series. Electric Valve Actuators 34-636- 771, Rev. D Installation Instructions VA-7450 Series Issue Date 0216 VA-7450 Series Electric Valve Actuators Applications VA-7450 Series Electric Valve Actuators provide on/off, floating, or proportional

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instruction for Electronic Pressure Switch. Model: PDD Operating Instruction for Electronic Pressure Switch Model: PDD 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-.. Operating Instructions for Polysulfone Paddle Monitor Model: -.. 1. Contents 1. Contents... 2 2. Note... 3 3. Regulation Use... 3 4. Operating Principle... 3 5. Instrument Inspection... 4 6. Mechanical

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

SPG-DIGI. Operating Instruction. Please read carefully before use!

SPG-DIGI. Operating Instruction. Please read carefully before use! WALTER STAUFFENBERG GMBH & CO.KG Im Ehrenfeld 4 D-58791 Werdohl Postfach 1745 D-58777 Werdohl Germany Tel.: +49 (0) 2392 / 916-0 Fax: +49 (0) 2392 / 2505 E-Mail: sales@stauff.com Internet: www.stauff.com

More information

Temperature multi-function calibrator Model CTM

Temperature multi-function calibrator Model CTM Calibration Temperature multi-function calibrator Model CTM9100-150 WIKA data sheet CT 41.40 for further approvals see page 3 Applications Testing and calibration of all types of temperature measuring

More information

GE Sensing & Inspection Technologies

GE Sensing & Inspection Technologies GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for

More information

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1 Model 340i / 680i / 1220i DC drive product manual HG102938 iss 8 1 Sprint Electric Limited, Arundel, UK Tel. +44 (0)1903 730000 Fax. +44 (0)1903 730893 Email. info@sprint-electric.com www.sprint-electric.com

More information

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

LS-1 Series Tungsten Halogen Light Sources

LS-1 Series Tungsten Halogen Light Sources LS-1 Series Tungsten Halogen Light Sources The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the VIS- Shortwave NIR range (360-2000 nm). These light

More information

Product information. ORION-PB Poultry computer for floor keeping

Product information. ORION-PB Poultry computer for floor keeping Product information Hotraco Agri BV Stationsstraat 142 5963 AC Hegelsom Tel +31 (0)77 327 50 20 Fax +31 (0)77 327 50 21 info@hotraco.com www.hotraco.com ORION-PB Poultry computer for floor keeping Poultry

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

GE Measurement & Control

GE Measurement & Control GE Measurement & Control Telaire Ventostat 8000 Series CO 2 Sensor User Instructions Installing the Sensor!WARNING! Before performing service or maintenance operations on the systems, turn OFF main power

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

Operating Instruction for Flowmonitor. Model: DF-WM

Operating Instruction for Flowmonitor. Model: DF-WM Operating Instruction for Flowmonitor Model: DF-WM 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 5 6. Mechanical Connection...

More information

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS Intelligent Battery System GmbH Seestrasse 24, CH-3600 Thun, Schweiz Tel: +41 33 221 06 16 Fax: +41 33 221 06 17 E-Mail: info@ibs-tech.ch Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS-USG4_en_v2.0.3.doc

More information

testo 535 Instruction manual

testo 535 Instruction manual testo 535 Instruction manual en Mains connection (mains unit no. 0554.0088) recommended for long-term measuring. 2 line display Hold/Max/Min button START/STOP ON/OFF button Screw-off battery compartment

More information

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V DSOS24V v.1.0 FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V EN* Edition: 2 from 30.08.2017 Supercedes edition: 1 from 24.05.2016 PSU features. Compliant with the requirements of the

More information

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art. Technical Documentation VAPORIX-PCM Corrective control module for connection to VAPORIX-Control Version: 3 Edition: 2016-08 Art. No: 350102 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Tel.:

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1 Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 1 This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises speed feedback

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

Intelligent Positioner

Intelligent Positioner Intelligent Positioner Construction The GEMÜ 1 µpos is a digital electro-pneumatic positioner for process valve control. Designed for simple, safe and quick use with valves with strokes < mm. The positioner,

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

Operating instructions Accu Jet

Operating instructions Accu Jet Operating instructions Accu Jet Keep for future use! Ident number: 04.8800.000 Air Line Table of contents 1 Scope of delivery... 4 2 Operator instructions... 5 3 Safety... 6 3.1 Intended use...8 4 Description

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when

More information

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT SAFETY- FLY 700 P FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR.1017.2 MIT USER MANUAL UK Manufacturer Preface : MC elettronica S.r.l. Address : Via E. fermi, 450/486 Fiesso Umbertiano (ROVIGO) - ITALY

More information

Solenoid valves MHJ, fast-switching valves

Solenoid valves MHJ, fast-switching valves Solenoid valves MHJ, fast-switching valves Solenoid valves MHJ, fast-switching valves Key features Innovative Versatile Reliable Easy to install Individual electrical connection via connecting cable and

More information

DKG-114 MANUAL AND REMOTE START UNIT

DKG-114 MANUAL AND REMOTE START UNIT DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional

More information

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160 Mechatronic pressure measurement Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160 WIKA data sheet PV 22.01 for further approvals see page 3 Applications

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

ES 200 STANDARD ES 200 EASY PLUS

ES 200 STANDARD ES 200 EASY PLUS ES 200 STANDARD ES 200 EASY PLUS Sliding door in compliance with DIN 18650 / EN 16005 with self-monitoring secondary closing edge protection ES 200 SLIDING DOOR OPERATOR MORE FLEXIBILITY AND EFFICIENCY

More information

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA Operating Instructions for Pressure Transmitter with Digital Display Model: PDA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Operating Principle... 3 5. Regulation Use...

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN Accessories for Stand-alone inverter SUNNY ISLAND GENMAN Technical Description GenMan-TEN082730 98-2001230 Version 3.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this manual..............................

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve) Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the CO level and outputs a 4-20 ma signal. The standard product features a 2- wire loop-powered output. Optionally, the device

More information

AWZ 110. AWZ 13,8V/1A/7Ah/LM

AWZ 110. AWZ 13,8V/1A/7Ah/LM AWZ 110 v.1.3 AWZ 13,8V/1A/7Ah/LM Linear buffer power supply unit Grade 2. EN* Edition: 9 from 02.11.2017 Supercedes the edition: 8 from 23.01.2017 GREY POWER plus Features: EN50131-6 compliance, 1 2 grades

More information

LGT-311L Bumper LED Light Kit EZ-Go RXV Installation Instructions

LGT-311L Bumper LED Light Kit EZ-Go RXV Installation Instructions LGT-311L Bumper LED Light Kit EZ-Go RXV Installation Instructions Caution: Please read through the instructions carefully. Before starting this project, remove the system s positive and negative connections

More information

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500 NANOPAC-300 & 500 Power Supply Instruction manual NANOPAC-300 & NANOPAC-500 Version 01C Feb 5th, 2014 1 Packing list NANOPAC-300 or 500-1x NANOPAC-300 Power Supply or NANOPAC-500-1x Power Cord - 1x Instruction

More information

VOC Duct and Rough Service Sensor

VOC Duct and Rough Service Sensor Overview and Identification Humans respirate Volatile Organic Compounds (VOCs) as well as CO 2. The BAPI sensor measures these VOCs and indicates space occupancy just as well as a CO 2 sensor. The advantage

More information

Operating Instructions for Paddle Flowswitch Model: PPS-...

Operating Instructions for Paddle Flowswitch Model: PPS-... Operating Instructions for Paddle Flowswitch Model: PPS-... 1. Note Please read and take note of these operating instructions before unpacking and commissioning. The instruments may only be used, maintained

More information

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2

More information

Technical Data and Operating Instructions Thermal Dry Running Protection ATLS-T1

Technical Data and Operating Instructions Thermal Dry Running Protection ATLS-T1 Technical Data and Operating Instructions Thermal Dry Running Protection ATLS-T1 Operational data for thermal dry running protection according to order data sheet Order No.: Ident No. ATLS-T1: Machine

More information

Control Box CBJ1 / CBJ2. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CBJ1 / CBJ2. Data sheet LINAK.COM/MEDLINE-CARELINE Control Box CBJ1 / CBJ2 Data sheet LINAK.COM/MEDLINE-CARELINE CBJ1 / CBJ2 The control boxes CBJ1 and CBJ2 are part of the battery driven JUMBO system. JUMBO is a modular system combining an actuator, a

More information

Actuator LA29. Data sheet LINAK.COM/HOMELINE

Actuator LA29. Data sheet LINAK.COM/HOMELINE Actuator LA29 Data sheet LINAK.COM/HOMELINE LA29 The LA29 actuator is a HOMELINE actuator specially made for domestic applications. The actuator has a very short installation dimension as the distance

More information

MWF+ Application. Types Available. Average temperature sensor. Datasheet

MWF+ Application. Types Available. Average temperature sensor. Datasheet MWF+ Average temperature sensor Datasheet Subject to technical alteration Issue date: 28.03.2018 A002 Application Duct averaging temperature sensor in enclosure USE-S for measuring the average temperature

More information

Ventilation Control. Ventilation Control 12

Ventilation Control. Ventilation Control 12 Ventilation Control One of our major markets is building automation where our sensors control individual fans, dampers, valves, etc. A common application is controlling ventilation in rooms with varying

More information

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content 1. About this document Operating instructions............pages 1 to 10 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

BNC BNC 12V/8x1A. Switch mode power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

BNC BNC 12V/8x1A. Switch mode power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition: BNC08128 v.1.0 BNC 12V/8x1A Switch mode power supply unit for CCTV. EN** Edition: 1 from 26.11.2013 Supersedes the edition: ------ GREEN POWER CCTV BNC PSU features: supply output 8x1A/12V DC output voltage

More information

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure 8.3 Online Sensor Specifications Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) Calibration: Accuracy: Remainder of range and other calibration material Overload protection Measuring principle Measuring

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed

More information

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

Know-how makes the difference. Limit Switches

Know-how makes the difference. Limit Switches Know-how makes the difference Limit Switches With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product development

More information

OPERATING INSTRUCTIONS C.A.R. Controlled Asphalt Replaster TYPE 30/275 TYPE 60/75 TYPE 90/100 TYPE 120/125 TYPE 120/150

OPERATING INSTRUCTIONS C.A.R. Controlled Asphalt Replaster TYPE 30/275 TYPE 60/75 TYPE 90/100 TYPE 120/125 TYPE 120/150 OPERATING INSTRUCTIONS C.A.R. Controlled Asphalt Replaster TYPE 30/75 TYPE 60/75 TYPE 90/100 TYPE 10/15 TYPE 10/150 Distributor: A+L Handels GmbH C.A.R. World Trade Eckstraße 8 60437 Frankfurt/M. Tel:

More information

Instruction manual Electric glass door lock Touch-to-open

Instruction manual Electric glass door lock Touch-to-open Instruction manual Electric glass door lock Touch-to-open OPERATING INSTRUCTIONS Touch to open electric glass door lock Operating instructions draft 09-2017_v1 Content 1 General 1.1 Performance Description

More information

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition: BNC08128C v.1.0 BNC 13,8V/8x1A/17Ah Switch mode buffer power supply unit for CCTV. EN** Edition: 1 from 26.11.2013 Supersedes the edition: ------ GREEN POWER CCTV BNC PSU features: DC 13,8V/8x1A uninterruptible

More information

SIGNET Temperature Transmitter

SIGNET Temperature Transmitter SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

EXKOP MINI + QV II Quench Valve. Explosion Isolation System

EXKOP MINI + QV II Quench Valve. Explosion Isolation System EXKOP MINI + QV II Quench Valve Explosion Isolation System page 1 of 25 Table of contents 1. Operating and safety instructions 3 1.1 Safety instructions 3 1.2 Application limitation 3 2. Description 4

More information

Product information. MIRA-P Poultry computer

Product information. MIRA-P Poultry computer Product information Hotraco Agri BV Stationsstraat 142 5963 AC Hegelsom, The Netherlands Tel +31 (0)77 3275020 Fax +31 (0)77 3275021 info@hotraco.com www.hotraco.com MIRA-P Poultry computer Poultry computer

More information

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch Edition 10/2016 HMI Components Series Characteristics The compact Series is especially suited for: Flush design The large rectangular design (24x36mm) features a large illuminated area. Functions The Series

More information

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor. ZONE PRESENCE SENSOR Phoenix Controls Zone Presence Sensor (ZPS ) detects the presence of personnel in front of a fume hood. When an operator is present, the ZPS signals the fume hood system into the standard,

More information

Translation of the Original operating instructions Lifting device Z 70 /...

Translation of the Original operating instructions Lifting device Z 70 /... Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks

More information

CHEMTROL 460 Control unit Technical information

CHEMTROL 460 Control unit Technical information SCHOTT Instruments Process holders and accessories CHEMTROL 460 Control unit Technical information All brand and product names are trademarks of the company SI Analytics Copyright notice Distributed by:

More information

product data sheet Usage: Duty cycle: Max 10% or 2 minutes continuous use followed by 18 minutes not in use Ambient temperature: +5 to + 40 C

product data sheet Usage: Duty cycle: Max 10% or 2 minutes continuous use followed by 18 minutes not in use Ambient temperature: +5 to + 40 C product data sheet ACTUATOR LA31 Features: 24V DC permanent magnet motor Thrust up to 6000 N in push and up to 4000 N in pull Electric chromated steel piston rod eye with slot High-strength plastic housing

More information

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution General description REVO is a compact family of solid state switches designed to replace contactors. Single phase thyristor units up to 40A.

More information

REVISED ATM72 Auto Transfer Module

REVISED ATM72 Auto Transfer Module Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Electrical linear actuator with safety function MC100FSR/230

Electrical linear actuator with safety function MC100FSR/230 Issue 2013-05-24 Operating manual 3.10-TA.210-10-EN Electrical linear actuator with safety function Application Linear actuator with automatic coupling and safety function for fine stroke adjustment of

More information

35 35A 50 50A 1 Single phase. Solid state power controller

35 35A 50 50A 1 Single phase. Solid state power controller Single Phase, Power Controller Single Phase, Power Controller Features Various and simple input specification DC4-2mA, 1-5VDC, External 24VDC External adjuster (1kΩ) External contact (ON/OFF) Various function

More information

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

RELAY BOX PRODUCT MANUAL IMPORTANT

RELAY BOX PRODUCT MANUAL IMPORTANT RELAY BOX PRODUCT MANUAL IMPORTANT Installer: This manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 TABLE OF CONTENTS Page INTRODUCTION

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has

More information

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup NT1-200, NT1-200/296 Battery Backup NT1-200 Add-on Battery Installation Instructions The Battery Backup units for Tone Commander NT1 Racks provide backup NT1 and terminal power (PS1 and PS2) during a power

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

TPE S-A-F-A-BUBE

TPE S-A-F-A-BUBE GRUNDFOS DATA BOOKLET TPE3-18-S-A-F-A-BUBE Grundfos Pump 98437648 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpes2/98437648/tpe3--18-s-a-f-a-bube.html

More information

LM 3188 PORT: LASER DUST MONITOR

LM 3188 PORT: LASER DUST MONITOR LM 3188 PORT: LASER DUST MONITOR CHOPPED LASER LIGHT SOURCE- EXCELLENT CHOICE FOR LOW DUST APPLICATIONS APPLICATIONS: Power plants Cement factories Iron and Steel factories Tunnels FEATURES: Manual Zero

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

CETOP POSITION PAPER PP 07

CETOP POSITION PAPER PP 07 CETOP POSITION PAPER PP 07 MACHINERY DIRECTIVE 2006/42/EC Valid since 26 th May 2010 CETOP General Secretariat Lyoner Straße 18 D-60528 Frankfurt am Main Phone: +49 69 6603 1201 Fax: +49 69 6603 2201 E-mail:

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

8000 Series Liquid Flow Meters

8000 Series Liquid Flow Meters PRODUCT DATA SHEET 8000 Series Liquid Flow Meters Advanced microprocessorbased flow measurement technology in a compact, leak-tight package Flow ranges from 0.2 to 227 LPM / 0.05 to 60 GPM Accuracy of

More information