Gas Purification Systems: Z Series
|
|
- Chester Jackson
- 5 years ago
- Views:
Transcription
1 Gas Purification Systems: Z Series Provides a continuous supply of pure XCDA (extreme clean dry air) purge gas EGPS8 shown Aeronex Gas Purification Systems provide a continuous supply of pure gas at the lowest cost-of-ownership. Aeronex Gas Purification Systems are dual-bed, selfregenerating systems. They are available in both standalone systems and panel-mounted subsystems. All stand-alone gas purification systems; the EGPS4, EGPS8, and EGPS12 models; include a user-friendly touch screen PC and standard safety features. All systems may be configured to order with multiple options such as a moisture indicator, manual or automatic bypass valves. The panel-mounted subsystems (PGPS4 models) are offered specifically to OEMs and are designed to be integrated into a process tool. Aeronex Gas Purification systems utilize Aeronex ambient temperature purification technology, have a lowpressure drop, and offer a low cost-of-ownership. Contaminants are removed to sub-ppb (part-per-billion) and ppt (part-per-trillion) levels; the level of purity required to enable your process. Method of Purification Contaminants are removed from the process gas to subppb levels. They are removed through chemisorption, physisorption, oxidation and oxidative addition. System Overview & Features Aeronex Gas Purification Systems use two purifier beds in order to maintain a continuous flow of pure gas. One purifier bed is on-line while the other is in regeneration or is ready for use. The proprietary regeneration process is performed by flowing hot gas through the purifier, which weakens the bonds holding the contaminants before carrying them away. The result is renewed purification capacity. After the bed returns to ambient temperature, the bed is placed in a stand-by mode and is ready to go back online. Power failure will not damage the purifier system. Aeronex Gas Purification Systems address the challenge of resource conservation and help meet industry environmental goals because of the lower energy costs afforded by the use of ambient temperature purification technology and in-situ regeneration, which eliminates hazardous waste. Start-up service is provided, making it easy to add an Aeronex Gas Purification System to your process. An on-site Mykrolis service technician ensures the smooth deployment of your new gas purification equipment and provides on-site training. The systems are designed to easily allow for field maintenance and upgrades. Industry Standards Aeronex Gas Purification Systems conform to CE and SEMI S2 requirements. P r o d u c t S p e c i f i c a t i o n
2 Aeronex Gas Purification Systems: Z Series - Product Features Applications The Z Series removes gaseous contaminants such as SO 2, SO x, NO x, H 2 S, H 2 O, CO 2, siloxanes, ammonia, amines, acid gases, alcohols, and non-methane hydrocarbons to sub-ppb levels in CDA (air) gas. System Process & Instrumentation Diagram P&ID for Models: PGPS4Z EGPS4Z EGPS8Z EGPS12Z The Z Series is beneficial in the following applications: Photolithography FOUP cleaning and purging Stocker cleaning and purging Other applications that require XCDA purge gas Available Models PGPS4Z - Panel-mounted model for OEM use. For applications requiring a flow rate up to 120 slm. EGPS4Z -Enclosed model for use with applications requiring a flow rate up to 120 slm. EGPS8Z-Enclosed model for use with applications requiring a flow rate up to 300 slm. EGPS12Z-Enclosed model for use with applications requiring a flow rate up to 1000 slm. Safety Features Safety Features Description PGPS4 EGPS4 EGPS8 EGPS12 N/A Circuit Breaker Over Temperature Rise Condition EMO Button Remote EMO Remote Alarm Visual Alarm Provides additional electrical protection to the system and includes a lockout/tag-out. Monitored via thermocouple. Heaters sized to prevent runaway conditions. As a secondary precautionary device, a high-temperate hardware interlock is included on the EGPS4. When activated, power is removed from the cabinet. The system shuts down. The front panel and controller remain powered. Provides input for remote EMO activation and an output for remote signal of EMO condition. In the event of a minor alarm in the system not requiring an EMO shutdown, the system will send a signal to an external sensing device which alerts the facility of the alarm. In the event of an alarm, a detailed description of the alarm will be displayed in red on systems that include a touch screen. In the event of an alarm on a system with LEDs, a red LED indicator will activate. N/A Audible Alarm Alarm conditions result in an audible alarm. N/A Isolated Electrical Enclosure Electronics are physically isolated from the main purifier cabinet in an attached electrical enclosure in situations where high voltage lines are near potentially flammable gas. N/A 2
3 Aeronex Gas Purification Systems: Z Series - Product Specifications Performance Specifications Model PGPS4 EGPS4 EGPS8 EGPS12 Gases Purified CDA (Air) Media Type Inorganic Contaminants Removed Volatile Acids, Volatile Bases, Refractory Compounds, Condensable Organics, Non-Condensable Organics, Moisture Outlet Purity < 1 part-per-billion (ppb)* Operating Pressure Range psig ( kpa) psig ( kpa) Pressure Drop < psig inlet and max rated flow < psig inlet and max rated flow Max Flow Rate 120 slm 300 slm 1000 slm Gas Operating Temperature -40 C to 60 C (-40 F to +150 F) Outlet Filtration % efficiency Leak Rating 1 X 10-9 atm cc/sec *Outlet purity is significantly lower for some contaminants. Test data available upon request. Facility Specifications* Process Gas Input Process Gas Output Ventilation Power Requirements Specifications PGPS4 EGPS4 EGPS8 EGPS12 1/4 Face Seal 1/4 Tube Stub 1/2" Tube Stub 3/4" Tube Stub 1/4 Face Seal 1/4 Tube Stub 1/2" Tube Stub 3/4" Tube Stub N/A 4 Duct Exhaust Flow N/A 50 cfm Standard Terminal Power Requirements VAC Power Consumption 50 Watts at idle and process mode; 275 Watts during regen 50 Watts at idle and process mode; 800 Watts during regen Regeneration Max Regen 3 Days (May be configured per customer inlet gas purity) Frequency Regen Duration 48 hours Regen Gas Output Pressure Atmospheric 1/4" Tube Stub Instrument Air Gas & Pressure CDA or N psig ( kPa ) 1/4 Compression Fitting Physical Requirements Mounting Wall Floor Shipping Weight 70 lbs (32 kg) 85 lbs (39 kg) 250 lbs (113 kg) 450 lbs (205 kg) Operating C Indoor ( F Indoor) Conditions Humidity 10-90% RH non-condensing *It is the customer s responsibility to ensure that the equipment is installed according to local building code requirements. 3
4 Aeronex Gas Purification Systems: Z Series - Model PGPS4 Model Dimensions & s [711 mm] [381 mm] FRONT VIEW [279 mm] SIDE VIEW TOP VIEW SYSTEM CONNECTIONS 1 Communications Port For user interface via PC 2 LED Indicators For Main Power, Bed Online, Bed Regen, Heaters, and Alarms 3 Start Used to begin system operations and to clear alarms 4 A/C Terminal Block Power connection 5 Gas Exhaust/Regen Vent Exhausts regen gas 6 Process Gas Input Inlet gas (not purified) 7 Process Gas Output Outlet gas (purified) PANEL INFORMATION This equipment is not enclosed, therefore, it is the user s responsibility to ensure that it is installed in compliance with local safety requirements for gas equipment. The PGPS4 is designed using SEMI S2 guidelines (for gas equipment enclosures), however, because it is a subsystem, it must be certified with the final product in which it is used. 4
5 Aeronex Gas Purification Systems: Z Series - Model EGPS4 Model Dimensions & s 3.00 [76 mm] [342 mm] * [813 mm] [457 mm] [305 mm] FRONT VIEW SIDE VIEW TOP VIEW SYSTEM CONNECTIONS 1 Audible Alarm Audible warning informs of alarm condition 2 Start Used to begin system operations and to clear alarms 3 EMO When activated, power is removed from the cabinet. The system shuts down. Front panel and controller remain powered. 4 Touch Screen For system status and interface 5 Circuit Breaker Provides additional electrical protection to the system and in some models also acts as an ON/OFF switch for the system. 6 Remote Alarm Interface Allows for remote alarm input and output with female 15 pin DB connector 7 Regen Gas Vent Exhausts Regen Gas 8 Exhaust Vent Allows ventilation 9 Process Gas Input Inlet gas (not purified) 10 Process Gas Output Outlet gas (purified) 11* Reference Atmospheric reference for the internal enclosure flow sensor. * N/A for Z Series 12 Instrument Air Supplies gas to the air operated control valves 13 A/C Power Input Power connection ENCLOSURE INFORMATION The ventilated enclosure is designed for indoor applications only. The enclosure has mounting locations on the back surface. The front panel is removable. 5
6 Aeronex Gas Purification Systems: Z Series - Model EGPS8 Model Dimensions & s [416 mm] [1497 mm] * [572 mm] FRONT VIEW [379 mm] SIDE VIEW TOP VIEW SYSTEM CONNECTIONS 1 Touch Screen For system status and interface 2 Audible Alarm Audible warning informs of alarm condition 3 Start Used to begin system operations and to clear alarms 4 EMO When activated, power is removed from the cabinet. The system shuts down. Front panel and controller remain powered. 5 Remote Alarm Interface Allows for remote alarm input and output with female 15 pin DB connector 6 Instrument Air Supplies gas to the air operated control valves 7 Exhaust Vent Allows ventilation 8 Process Gas Input Inlet gas (not purified) 9 Circuit Breaker Provides additional electrical protection to the system and in some models also acts as an ON/OFF switch for the system. 10* Reference Atmospheric reference for the internal enclosure flow sensor. *N/A for Z Series 11 Process Gas Output Outlet gas (purified) 12 A/C Power Input Power connection ENCLOSURE INFORMATION The ventilated enclosure is designed for indoor applications only. The enclosure has bolt down locations on the bottom surface. The front panel is removable. 6
7 Aeronex Gas Purification Systems: Z Series - Model EGPS12 Model Dimensions & s 4.03 [102 mm] [1831 mm] 5 6 7* * 11 12* [622 mm] FRONT VIEW [454 mm] SIDE VIEW TOP VIEW SYSTEM CONNECTIONS 1 Touch Screen For system status and interface 8 Exhaust Vent Allows ventilation 2 Audible Alarm Audible warning informs of alarm condition 9 Process Gas Output Outlet gas (purified) 3 Start Used to begin system operations and to clear alarms 10* Gas Monitor Located Below Cover. * N/A for Z Series 4 EMO When activated, power is removed from the cabinet. The system shuts down. Front panel and controller remain powered. 11 Instrument Air Supplies gas to the air operated control valves 5 Remote Alarm Interface Allows for remote alarm input and output with female 15 pin DB connector 12* Reference Atmospheric reference for the internal enclosure flow sensor. *N/A for Z Series 6 Process Gas Input Inlet gas (not purified) 13 Circuit Breaker Provides additional electrical protection to the system and in some models also acts as an ON/ OFF switch for the system. 7* Fire Sensor Located Below Cover - *N/A for Z Series 14 A/C Power Input Power connection ENCLOSURE INFORMATION The ventilated enclosure is designed for indoor applications only. The enclosure has bolt down locations on the bottom surface. The front panel is removable. 7
8 * Consult factory for more information. Z Series - Options & Ordering Information PGPS4 EGPS4 EGPS8 EGPS12 Panel-mounted model for OEM use. For applications requiring a flow rate up to 120 slm. Options Options Letter PGPS4 EGPS4 EGPS8 EGPS12 Designator Automatic Bypass Manifold A Manual Bypass Manifold M Moisture Indicator T Japanese Kit J N/A High Flow * N/A N/A N/A Available Part Numbers For use with applications requiring a flow rate up to 120 slm. For use with applications requiring a flow rate up to 300 slm. For use with applications requiring a flow rate up to 1000 slm. PGPS4Z EGPS4Z EGPS8Z EGPS12Z PGPS4ZA EGPS4ZA EGPS8ZA EGPS12ZA PGPS4ZAT EGPS4ZAT EGPS8ZAT EGPS12ZAT PGPS4ZM EGPS4ZATJ EGPS8ZATJ EGPS12ZATJ PGPS4ZMT EGPS4ZAJ EGPS8ZAJ EGPS12ZAJ PGPS4ZT EGPS4ZM EGPS8ZM EGPS12ZM EGPS4ZMT EGPS8ZMT EGPS12ZMT EGPS4ZMTJ EGPS8ZMTJ EGPS12ZMTJ EGPS4ZMJ EGPS8ZMJ EGPS12ZMJ EGPS4ZT EGPS8ZT EGPS12ZT EGPS4ZTJ EGPS8ZTJ EGPS12ZTJ EGPS4ZJ EGPS8ZJ EGPS12ZJ Model Gas Series Options EGPS8 Z MJ Please contact your Mykrolis applications specialist for assistance in ordering your Aeronex Gas Purification System. All specifications are subject to change. Please verify prior to order. US Patent 6,361,696 8 Consult our applications specialists with any questions. Aeronex, Mykrolis, and XCDA are registered trademarks of Mykrolis Corporation. The Mykrolis logo is a trademark of Mykrolis Corporation. Legal/Trademarks: Worldwide Offices: U.S: Europe: Billerica, MA France Allen, TX Germany San Diego, CA Asia: Japan: Singapore Tokyo Korea Kyushu People's Republic of China Osaka Taiwan Lit. No. PF1117ENUS Rev. B 06 January 2005 Printed in the U.S.A Mykrolis Corporation. All rights reserved. Mykrolis logo Mykron Mykron Microelectronics Co., Ltd. 上海资方微电子有限公司 Suite 318, B Office Tower, Poly Plaza No.14, Dong Zhi Men Street (South), Dong Cheng District Beijin g, , China Tel. ( 86) Fax (86)
we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.
we make clean air Air Filtration Solutions Industrial Commercial Residential Che mic al F ilte r HE PA Filt er Filter Although very effective against very fine particles, filters do not filter out gasses
More informationGENCORE 5 FUEL CELL SYSTEM System Fundamentals
GENCORE 5 FUEL CELL SYSTEM System Fundamentals GenCore 5T48 GenCore 5B48 GenCore 5U48 GenCore 5T24 GenCore 5U120 Revision 1 December 1, 2004 GENCORE DESCRIPTION GenCore fuel cell systems are direct hydrogen
More informationProtector Glove Boxes.
Protector Glove Boxes www.labconco.com Glove Boxes, An Overview The purpose of a glove box is to provide a physical barrier. Depending on the type of glove box, the physical barrier may be: Isolating a
More informationUniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model
UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and
More informationExtended Battery Cabinet for Nfinity
POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................... 1 ELECTROMAGNETIC COMPATIBILITY.......................................
More informationP70, P72, and P170 Series Controls for High Pressure Applications
Installation Instructions P70 Issue Date 0918 P70, P72, and P170 Series Controls for High Pressure Applications Application P70, P72, and P170 Series Controls for High Pressure Applications provide high-side
More informationInstallation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount
Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before
More informationCR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure
P/N 01-1012769 REV. F 07/18 INSTRUCTION SHEET CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure Entegris CR4 valves and manifold valves can be repaired or replaced in the event of valve
More informationTHC Heated FID 3-300A
Rack Mount/Table Top TVOC Analyzer THC Heated FID 3-300A Space saving 19"/3PU space saving rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of
More informationEDC DRY CLAW VACUUM PUMPS
edwardsvacuum.com EDC DRY CLAW VACUUM PUMPS INNOVATION AND RELIABILITY Edwards EDC range is a new generation of robust single stage dry claw vacuum pumps The new range of our EDC dry claw pumps features
More informationOIL-FREE, ROTARY SCREW AIR COMPRESSORS Two-stage, Air-cooled and Water-cooled Fixed Speed or VFD
OIL-FREE, ROTARY SCREW AIR COMPRESSORS Two-stage, Air-cooled and Water-cooled Fixed Speed or VFD 40-500 HP 170-2400 SCFM 40-150 PSIG www.knw-series.com High Quality, Quiet and Energy Efficient Both compression
More informationInstallation Manual. YASKAWA AC Drive Option Back-up Capacitor Unit for Momentary Power Loss. Type: P0010, P0020
YASKAWA AC Drive Option Back-up Capacir Unit for Momentary Power Loss Installation Manual Type: P0010, P0020 To properly use the product, read this manual thoroughly and retain for easy reference, inspection,
More informationAutomatic Changeover Medical Manifold Installation, Operation and Maintenance Manual
Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783 Model Number:
More informationPowerAir Compressor Installation
PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model
More informationClassicSeries Compressor Installation
ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:
More informationElectrical Installation
Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE
More informationHybrid UPS Saves Energy and Achieves High Reliability. Output capacity. 3 kva. 2 kva. Output capacity. 2.1kW. 1.4kW
HYBRID UPS E11A Hybrid UPS Saves Energy and Achieves High Reliability SANUPS HYBRID UPS E11A 19 inch NETWORK rack MONITORING Mountable EIA 100V model Input AC100,110,115,120V Single-phase 200V model Input
More informationMiretti Flameproof 1MIRETTI. Technology Jan. 1st, 2014 Editor: Max Huang Mp:
Miretti Flameproof 1 Technology Jan. 1st, 2014 Editor: Max Huang Email: Max.huang@miretti.net Mp: +86-158 2100 7175 1 MARKETS Miretti products: 2 flameproof conversions of: Electric & diesel forklift trucks
More informationInstallation and Operation Manual Back-UPS BX1100CI-CN
Installation and Operation Manual Back-UPS BX1100CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or
More informationStart UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva
Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE
More informationP66 Series Electronic Fan Speed Controls
FANs 125, 121 Pressure Controls Section P Product/Technical Bulletin P66 Issue Date 0498 P66 Series Electronic Fan Speed Controls The P66 is a pressure actuated electronic motor speed controller. This
More informationCYCLOPS Z Purge Indicator
Low cost Simple to install & use Highly reliable & maintenance free Enclosure vent is part of casing Local & remote status indicator Casing available in anodized aluminum & 316 stainless steel 12 or 24
More informationEBARA Turbomolecular Pumps
EBARA Turbomolecular Pumps Model EBT Innovative Technology. Ceramic-Bearing Model EBT Model EBT EBARA s Model EBT are mechanical-bearing, compound turbomolecular pumps which compliment EBARA s existing
More informationLABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL
LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL Content 1. Introduction...2 2. Important safety instruction...3 3. System component...4 4. Engineering design overview...5 5. Installation...6
More informationDymension SG Manifold Valves Using Direct Mount Manifold Technology
P/N 01-023283 REV. B 07/18 INSTRUCTION SHEET Dymension SG Manifold Valves Using Direct Mount Manifold Technology Repair instructions for 710 series manifolds Manifold Assembly P2 P3 P5 REPAIR PROCEDURE
More informationInstallation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA
Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
More informationUltra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26
Electronic Pressure Measurement Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA Datasheet WU-2X Applications Gas panels for OEM tools Semiconductor, flat panel display and photovoltaic
More informationEXPLOSION PROOF. Diesel Engines For Hazardous Areas
EXPLOSION PROOF Diesel Engines For Hazardous Areas HAZARDOUS AREAS Managing the Risk There is always a risk of a flammable hydrocarbon release in the oil and gas industry. When the release comes into contact
More informationEXPLOSION PROOF. Diesel Engines For Hazardous Areas
EXPLOSION PROOF Diesel Engines For Hazardous Areas HAZARDOUS AREAS Managing the Risk There is always a risk of a flammable hydrocarbon release in the oil and gas industry. When the release comes into contact
More informationVWR Zero Air Generator
Technical Information Installation, Operation, and Maintenance Manual VWR 89237-564 Zero Air Generator Figure 1 - VWR Zero Air Generator These instructions must be thoroughly read and understood before
More informationMarine Fuel Filtration Marine 800 Series
Racor recyclers offer large diesel engine operators both ease of maintenance and continuous engine operation. Continuous operations include filter changeouts and the draining of accumulated water from
More informationSpecification GS329 1
N:\DEPTS\TECHPUB\SPECIFICATIONS\GS329-2008-06-02.FM1 REVISED JUNE 2, 2008 11:53 AM1 Specification GS329 1 myreflow.com Soldering System Manufacturer: Vitronics Soltec (Suzhou) Co., Ltd. Workshop II, 858
More informationProduct Information ROSS CONTROLS
Product Information Minimize Hose Whip Flow Diffuser AIR-FUSE 19 Series ROSS CONTROLS AIR-FUSE Flow Diffusers Minimize Hose Whip 19 Series The ROSS AIR-FUSE Flow Diffuser automatically reduces air flow
More informationUpdated: October 2012
T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information
More informationSafety and General Information
Safety and General Information Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety
More informationCYCLOPS Z Purge Indicator
Low cost Simple to install & use Highly reliable & maintenance free Enclosure vent is part of casing Local & remote status indicator Casing available in anodized aluminum & 316 stainless steel 12 or 24
More informationThermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment
Thermo Scientific 1300 Series A2 Class II, Type A2 Biological Safety Cabinets Good for you good for the environment Thermo Scientific 1300 Series A2 Enjoy best-in-class performance and value g Superior
More informationP70, P72 and P170 Series Controls for High Pressure Applications
Installation Instructions P70 Issue Date October 16, 2002 P70, P72 and P170 Series Controls for High Pressure Applications Application P70, P72 and P170 Series Controls for High Pressure Applications provide
More informationInstallation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount
Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,
More informationInVue Electronic Flowmeter, NT4400
ADVANCED MATERIALS HANDLING InVue Electronic Flowmeter, NT4400 Provides simultaneous flow and pressure outputs Whether it s automation, process control or safety concerns that require flow and pressure
More informationSilentFlo Hydraulic Power Units. Quiet, reliable and efficient power generation. be certain.
l SilentFlo Hydraulic Power Units Quiet, reliable and efficient power generation be certain. Reliable power from a proven source. Trust one of the world s leading providers of servohydraulic test systems
More informationDescription. Measurement Principle. Key Features. Applications. Malema SUMOFLO. 1 Barb Single-Use Sensor for g/min
1 Barb SingleUse Sensor for 10000 100000 g/min U.S. PATENT 8404076 U.S. PATENT 8887578 JAPANESE PATENT 5602884 OTHER PATENTS PENDING Key Features Accuracy: ±1% of mass flow rate reading; unaffected by
More informationRosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:
Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference
More informationCYCLOPS X Purge Controller SM Version
Simple to install & use Highly reliable Purge exhaust vent is part of unit enclosure Local & remote status alarms Enclosure is 316 stainless steel 115 VAC up to 25 Amps or 230 VAC up to 12.5 Amps All in
More information50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant
D I E S E L G E N E R A T I N G S E T GEP30-2 (3-Phase) 50 HZ STANDBY PRIME 30.0 kva / 24.0 kw 27.0 kva / 21.6 kw FEATURES GENERATING SET l Complete system designed and built at ISO9001 certified facility
More informationAt Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.
1 ABOUT US Amico Corporation is a leading manufacturer of Medical Equipment, selling its products through a global distribution channel from three manufacturing facilities in Canada and the U.S. With a
More informationVariStroke II Electro hydraulic Actuator
Product Specification 03378 (Revision B, 9/2013) Applications VariStroke II Electro hydraulic Actuator The VariStroke-II is a linear electro-hydraulic actuator that is designed to provide the linear actuation
More information500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION
High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry FEATURES Primary standard, dimensionally based piston prover system Accuracy: CalTrak 500: up to +/- 0.35% of reading mass
More informationClass I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet
Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet Airstream Class I Biosafety Cabinet, Model AC1-4E8 RS 232 Port and Zero Volt Relay Contact RS
More informationPneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007
Pneutronics Miniature Proportional Valves January 2007 Non-Thermally Compensated Proportional Valve HF 200 Miniature Ultra High Flow Proportional Valve HF 200 is a high flow proportional valve that provides
More informationquatroair.com AIR TECHNOLOGIES INC.
quatroair.com AIR TECHNOLOGIES INC. LaserBlue Gel Zero Filter Bypass. Guaranteed! Designed to meet the most stringent cleanroom requirements, the LaserBlue gel forms an impenetrable barrier against the
More information50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant
D I E S E L G E N E R A T I N G S E T GEP33-1 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 33.0 kva / 26.4 kw 30.0 kva / 24.0 kw 37.5 kva / 30.0 kw 33.8 kva / 27.0 kw FEATURES GENERATING SET l Complete
More informationSpiracle Crankcase Filtration Technology
Technical Article Spiracle Crankcase Filtration Technology Author: Veli Kalayci Spiracle Systems Team Leader Figure 1 emissions Contributions tailpipe & CrAnkCAse Percent of Total PM Emissions 100% 90%
More informationLifeline Medical Systems
Installation, Operation and Service Manual Lifeline Medical Systems Fully-Automatic Manifold For Use With Liquid Cylinders LQ x HP Liquid x High-Pressure Models Part No. 6-847703-00 Rev. C00 Pg. 1 Introduction
More informationG2 Portable oxygen concentrator User Manual
G2 Portable oxygen concentrator User Manual Table of contents 1. Introduction......2 2. Important Safety Rules....3 3. Unpack your Lovego... 4 4. User Controls & System Status Indicators... 5 5. Quick
More informationBulk Liquid Filtration
Low Pressure, High Flow Filters Duramax Spin-On Filters Manifolds Breathers, Water Seperators Gauges, Valves, Test Points, more www.donaldson.com Brochure No. IH00501 Rev 4/05 Why install filtration on
More informationInstallation and Operation Back-UPS BX550CI-CN
Installation and Operation Back-UPS BX550CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there
More informationPARALLEL PROCESSING UPS E33A
PARALLEL PROCESSING UPS E33A Low energy, high quality, high reliability parallel processing type UPS E33A Supporting network PARALLEL PROCESSING UPS Parallel operation backup time Input AC380, 400, 415,
More informationPRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range
Valve Solutions w w w. m k s i n s t. c o m Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves Isolating and close-loop controlling each variable
More informationPREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS
PREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS AMP-O-LECTRIC GII Terminator Safety first. Improved guarding on the Model G II terminator provides open access for
More informationMaxwell s Highest Power and Energy Cell
DATASHEET 3.0V 3400F ULTRACAPACITOR CELL BCAP3400 P300 K04/05 Maxwell s Highest Power and Energy Cell Maxwell Technologies 3V 3400F ultracapacitor cell is designed to support the latest trends in renewable
More informationFILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL
FILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL ISSUE A 6 TH December 2013 2 CONTENTS SECTION 1... 5 DESCRIPTION OF THE CABINET... 5 SECTION 2... 6 INSTALLATION... 6 TESTING
More informationHigh Performance Vector Control Drive Manual Supplement
YASKAWA AC Drive-A1000 High Performance Vector Control Drive Manual Supplement Supplement to: A1000 Quick Start Guide TOEPC71061641C Type: CIMR-AU A Models: 200 V Class: 0.4 to 110 kw (3/4 to 175 HP
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationUser Manual Back-UPS BX650CI-MS 230 Vac with AVR
User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety
More informationINFORMER. in-line fluid monitoring package. The easy, affordable way to measure fluids, reduce waste and save money
INFORMER in-line fluid monitoring package The easy, affordable way to measure fluids, reduce waste and save money Finally an INFORMER is a great tool for reducing paint waste, collecting data and improving
More informationS Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9
Miniature Valve Series............................................................3-14 RB Series..................................................................................3-6 Technical Data...................................................................................3
More informationSMT Power Inductor High Current Molded Power Inductor - PA4342.XXXNLT Series
Height: 4.0mm Max Footprint: 11.5mm x 10.3mm Max Current Rating: up to 43.0A Inductance Range: 0.15uH to 68.0uH Shielded construction and compact design High current, low DCR, and high efficiency Minimized
More informationAdvanced Small Cell with XP Technology
DATASHEET 3.0V 3F ULTRACAPACITOR CELL BCAP0003 P300 X11 / X1 Advanced Small Cell TM with XP Technology Maxwell Technologies 3V 3F ultracapacitor cell is part of Maxwell s latest full-featured 3.0V product
More informationSANUPS. Non Toxic Lead-Acid Batteries Online UPS. Maintenance-free for 10 Years. Compact and Lightweight. Constant, Stable-Quality Power Supply
ON LINE UPS Non Toxic Lead-Acid Batteries Online UPS SANUPS ON LINE UPS With Nickel-Hydrogen Battery Online UPS Supporting Network 19-inch Rack Mountable JIS/EIA 100V model Input AC100, 110, 115, 120V
More informationTechnical Information Liquiline System CAT810
TI01138C/07/EN/02.16 71341422 Products Solutions Services Technical Information Control of sample preparation by the Liquiline System CA80 or a time control system Automatic sample preparation system for
More informationOn Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual
On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains
More informationRT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide
RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input 208-240 Vac Output 208-120 Vac User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY
More informationPREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS
PREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS AMP-O-LECTRIC GII Terminator Safety first. Improved guarding on the Model G II terminator provides open access for
More informationSMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter
Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays
More informationCustomized Solutions. Safety & Reliability Stainless steel 316 products
Customized Solutions Safety & Reliability Stainless steel 316 products REDUNDANT CONTROL SYSTEM (RCS) Applications Emergency Shutdown Systems Burner Management Systems Isolation and Venting Systems High
More informationFluoroLine Ultrapure PFA Tubing
ADVANCED MATERIALS HANDLING FluoroLine Ultrapure PFA Tubing Excels in ultrapure, chemically corrosive applications Entegris offers a complete line of tubing to satisfy your need for an ultraclean, leak-free
More informationInstallation and Operating Manual
Installation and Operating Manual OIL-LESS RECIPROCATING AIR COMPRESSOR CIL Series INSTALLATION & OPERATING MANUAL OIL-LESS RECIPROCATING AIR COMPRESSOR TABLE OF CONTENTS Page 1 DESCRIPTIONS A. GENERAL
More informationStandard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA
V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven
More informationSeries 120/120VAC Universal Tower/Rack Mount
V Series 120/120VAC Universal Tower/Rack Mount Standard 1000VA, 1500VA, 2000VA & 3000VA LB Extended Models 900VA, 1250VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features
More informationOn-line, Single Phase, Double Conversion UPS
V Series Standard Universal Tower/Rack Mount 1, 2, 3 kva On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven Digital Signal Processor (DSP) achieving high reliability, while
More information3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006; Amended December 15, 2011) 1.0 Purpose The purpose
More information50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes
D I E S E L G E N E R A T O R S E T GEP550-2 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET l Complete system designed and built at ISO9001 certified facility l
More informationModel DS1000/DT20 System
Model DS1000/DT20 System Installation, Commissioning and Operation Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 Email: mail@amsytems.co.uk
More information50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes
D I E S E L G E N E R A T O R S E T GEP450-1 (3-Phase) 50 HZ STANDBY 450 kva / 360 kw 400 kva / 320 kw FEATURES GENERATOR SET l Complete system designed and built at ISO9001 certified facility l Factory
More informationCYCLOPS X Purge Controller XP Version
Simple to install & use Highly reliable Enclosure purge exhaust vent is part of casing Local & remote status alarms Casing available in anodized aluminum or 316 stainless steel 115 VAC, up to 25 Amps or
More informationDH-2000 Deuterium-Halogen Light Source Installation and Operation Manual
DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual For Products: DH-2000 / DH-2000-BAL / DH-2000-DUV / DH-2000-S / DH-2000-S-DUV / DH-2000-FHS, DH-2000-FHS-DUV /DH-2000-S-DUV-TTL
More informationMerkur. High Performance Fine Finish Packages
High Performance Fine Finish Packages Advanced Technology. Superior Performance. The new and improved packages are designed to outperform and outlast other pumps in their class. With more models and configurations
More information50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant
D I E S E L G E N E R A T I N G S E T GEP65-5 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 65.0 kva / 52.0 kw 60.0 kva / 48.0 kw 75.0 kva / 60.0 kw 68.8 kva / 55.0 kw FEATURES GENERATING SET l Complete
More informationEstablished leaders in Actuation Technology. ROM & RBM Range 1/4 turn direct drive electric actuators. Publication E611E issue 10/02
Established leaders in Actuation Technology ROM & RBM Range 1/4 turn direct drive electric actuators Publication E611E issue 10/02 Rotork Actuation Established Leaders in Actuation Technology As one of
More information50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded
D I E S E L G E N E R A T I N G S E T GEP88-1 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 88.0 kva / 70.4 kw 80.0 kva / 64.0 kw 100 kva / 80.0 kw 90.0 kva / 72.0 kw FEATURES GENERATING SET l Complete
More informationTURBOMOLECULAR PUMPS ATP SERIES
TURBOMOLECULAR PUMPS ATP SERIES TURBOMOLECULAR PUMPS ATP SERIES Introduction The ATP conventional turbomolecular pumps have a proven track record of reliability. Rotors made exclusively from carefully
More information50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes
D I E S E L G E N E R A T O R S E T GEP165 (3-Phase) 50 HZ STANDBY PRIME 165 kva / 132 kw 150 kva / 120 kw Model will differ from picture shown FEATURES GENERATOR SET l Complete system designed and built
More information50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes
D I E S E L G E N E R A T I N G S E T GEH275 (3-Phase) 50 HZ STANDBY PRIME 275 kva / 220 kw 250 kva / 200 kw FEATURES GENERATING SET l Complete system designed and built at ISO9001 certified facility l
More informationSPECTRACOOL SLIM FIT AIR CONDITIONERS EQUIPMENT PROTECTION
SPECTRACOOL SLIM FIT AIR CONDITIONERS Design with CONFIDENCE EQUIPMENT PROTECTION THE ULTIMATE IN COOLING CONVENIENCE Loaded with features and options to take the hassles out of industrial cooling. Spectracool
More informationPower Inverter. User s Manual. Diamond Series CPD1200EILCD
Power Inverter Diamond Series CPD1200EILCD User s Manual 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5 2-2 Product Overview & Outlook..5 2-3 Power Requirements
More informationEngine Emission Control 6.7L Diesel
Page 1 of 6 SECTION 303-08: Engine Emission Control 2011 F-250, 350, 450, 550 Super Duty Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 03/12/2010 Engine Emission Control 6.7L Diesel
More informationFurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008
FurnaceDoctor -DPT Dewpoint Analyzer User Manual Version 008 Manual FurnaceDoctor -DPT - Version 8 Page 2 of 13 Manual #: 003 Rev No: 8 COPYRIGHT (C) No part of this publication may be reproduced, transmitted,
More informationRULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) 1.0 Purpose The purpose of this rule is to limit emissions
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More information