EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Volume flow meter with throttle- and bypass valve KUZ-L
|
|
- Job Booker
- 5 years ago
- Views:
Transcription
1 with throttle- and bypass valve Use: In oil lubrication systems H Viscosity-independent volume flow monitoring High measuring accuracy ig monitoring range Continuously adjustable volume flow Gearwheels can be cleaned or exchanged during operation Low throughput resistance Magnetic field sensor with function display (LE) Visual operating status display A P A P Note on dimensional drawing: A = Outlet connection = ypass valve = Throttle (Allen key W 6) P = Inlet connection H = Visual operating status display = Magnetic field sensor with throttle- and bypass valve Postfach 1661 E Wertheim Hafenstrasse E Wertheim Replaces No. Page 1 of EN EN
2 H Z Construction: The volume flow meter consists of the following components: ase body Z = Gearwheel pair = Throttle = ypass valve = Magnetic field sensor H = visual operating status display Volume flow measurement: Function scheme Z The fluid flowing through causes two gearwheels "Z" gearing into each other to rotate. Outside the pressure range, there is a sensor "" scanning the movement of the gearwheels "Z". The volume flow is determined by summing the measuring pulses up. Volume flow adjustment: The throttle valves "" can be used to adjust the volume flow. ypass: For replacing or cleaning the gearwheels "Z", the set volume flow can be diverted directly to the outlet connection through bypass valve "". Technical data: Minimum distance for the installation of several volume flow meters Flow volume: approx l/min Volume per electric pulse: 75,0 cm³ Lubricant: Mineral oil ( others media available upon request) The intended lubricant must be suitable for use with centralized lubrication equipment. Operating viscosity: mm²/s Operating pressure: at max. 5 bar Temperature range: C Mounting position: as needed Materials: Housing material: Al Viewing glass: PMMA ealing material: FPM (Viton) Gearwheel material: Metal Important note: The values stated above are maximum values and must not be attained concurrently. Postfach 1661 E Wertheim Hafenstrasse E Wertheim Page of 5
3 Magnetic field sensor with LE: Casing material: rass nickel-coated Operating voltage: VC Residual ripple: 10 % Constant current: 300 ma Own current consumption: 10 ma Voltage drop: 1,5 V Protection type: IP 67 Version "" plug-type connection: Connection type: M1x1, 4-pin (for proper cable jack see accessories) Connection diagram: Visual operating otatus display: The visual operating status display is actuated by an external evaluation unit. This enables the operating condition to be displayed visually. Operating voltage: VC Power consumption per colour: 16 ma Protection type: IP65 Casing material: Polyamide Three different signal colours can be displayed: green yellow red Example: green = Target status yellow = Pre-warning red = Fault Evaluation equipment, please inquire if necessary. Version "" plug-type connection: Connection type: M1x1, 4-pin (for proper cable jack see accessories) Connection diagram: LE red = Pin 4 3 LE green = Pin 3 LE yellow = Pin 4 3 grün rot Rv Rv Microprocessor-control for KUZ Monitoring and Evaluation: For more information see data sheet P0518. Please note the following: However, if the magnet field sensor pulses are evaluated by means of a common P, then quick counter inputs have to be used at the P. Please confer with us, if necessary. Postfach 1661 E Wertheim Hafenstrasse E Wertheim Page 3 of 5
4 Purchase-designation: Number of measuring points Visual operating ypass Magnetic field sensor Volume flow status display 1) with plug 1 with with plug approx l/min G without 0 Purchase-example: For a volume flow meter with 1 measuring point, bypass, magnetic field sensors and visual operating status display with plugs each, volume flow "G". estell-ezeichnung: / 1 / / / / G 1) Evaluation unit required pare parts: Accessories: esignation esignation esignation Plate translucent with mounting material Gearwheel pair Throttle screw "G" Gasket kit Magnetic field sensor "" with plug Visual operating status display "" with plug Cable socket M1 4-pin, 5m Postfach 1661 E Wertheim Hafenstrasse E Wertheim Page 4 of 5
5 Important information on this publication Reproduction, also in extracts, only permitted with the approval of the firm of EUGEN WOERNER GmbH & Co. KG. All the information in this publication has been examined for correctness with great care. Nevertheless, WOERNER cannot assume any liability for losses or damage resulting directly or indirectly from the application of the information contained in this publication. All products from WOERNER may only be used as intended and corresponding to the information in this publication. For products supplied with operating instructions, the additional directives and information contained in them are to be complied with. Materials deviating from those mentioned in this publication and the technical documents which further apply may only be poured into and processed in the appliances and systems manufactured and supplied by WOERNER by following agreement with and written approval by WOERNER. The safety and danger information stated in the safety data sheets of the substances used must be taken into account at all costs. Transportation of gases, liquefied gases, gases under pressure, vapours and liquids, the vapour pressure of which is more than 0,5 bar above normal atmospheric pressure (1013 mbar) at the maximum admissible temperature, of easy inflammable or explosive media as well as transportation of foodstuffs is forbidden. Information on EU irective 00/95/EC (RoH) With irective 00/95/EC of January 7, 003, for the limitation of the use of certain hazardous substances in electrical and electronic devices (RoH) material bans come into effect from July 006 for electrical and electronic devices newly placed on the market for lead, cadmium, hexavalent chromium, mercury and brominated flame retardants. In its controls and switching devices, WOERNER only uses materials which fulfil the criteria of EU irective 00/95/EC. To the extent that hexavalent chromium has been used as corrosion protection in the parts which we produce ourselves, it has already been replaced by other environmentally tolerable protective measures. The mechanical devices supplied by WOERNER are not affected by EU irective 00/95/EC as they are appliances added or installed on "large-scale stationary industrial tools" (cf. EU irective 00/96/EC, Annex IA). ut as WOERNER is conscious of its responsibility towards the environment, we shall also use materials fulfilling the requirements of the irective for devices not covered by EU irective 00/95/EC as soon as they are generally available and their use is technically possible. Postfach 1661 E Wertheim Hafenstrasse E Wertheim Page 5 of 5
EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPB
Progressive distributor VPB Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. different proportioning
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPA-D
Progressive distributor VPA-D Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. Clear and
More informationOne-line distributor e.g. VEI-A. One-line aggregate GEI-A
Ungültig!!! Ersatz: P0768 GE71 One-line aggregate GEI-A Use: This aggregate is used as pump in central lubrication systems that are based on the one-line principle. General construction: Essentially, the
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-B
Progressive distributor VPA-B Use: In progressive mode based central lubrication systems. The main features of WOERNER- progressive distributors are as follows: Accurate proportioning volumes. Clear and
More informationFlow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.
1-3004-EN Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems. Flow limiters are used in circulating-oil lubrication systems. The task of a flow limiter is to divide up the
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-C
Progressive distributor VPAC Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. Clear and
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 D Wertheim Am Eichamt 8 D Wertheim
Progressive distributor in element construction VPI-D Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: 4 different proportioning
More informationFlow limiter SP/SMB3 Flow limiter SP/SMB6
-00-EN Flow limiter SP/SMB Flow limiter SP/SMB6 for circulating-oil lubrication systems Advantages reliable perpetual dispensation of individual volume flows - self-adjusting metering, thus identical volume
More informationUD and UC Gear pump unit
1-19-EN for SKF CircOil or hydraulic lubrication systems General Information The UC and UD gear pump units are vertically or horizontally arranged units that are used in hydraulic or circulating-oil lubrication
More informationFlow limiter SP/SMB9 for mounting plates
1-3002-EN Flow limiter SP/SMB for mounting plates Advantages reliable perpetual dispensation of individual volume flows - self-adjusting metering, thus identical volume flows despite different back pressures.
More informationInjection Oilers, Micro Pumps
Injection Oilers, Micro Pumps 1-5012-4-US for minimal quantity metering Magnetic piston pump Injection oiler Micropump Grease metering P Metering pumps deliver and meter out lubricants. This piston pumps
More informationElectric Plug-and-Socket Connectors
-70-EN Electric Plug-and-Socket Connectors Sockets for pressure switches, level switches, flow sensors, directional control valves and filters DIN EN 750-80/ISO 4400 DIN EN 750-804 M Electric plugs or
More informationInjection oilers, micro pumps for minimal quantity metering
1-5012-4-EN Injection oilers, micro pumps for minimal quantity metering Injection oiler, 3-port type Injection oiler, 1-port type Micro pump Delivery rates Metering pumps deliver lubricants in a measured
More informationFlow limiter SP/SMB 8... DSK US (09.04)
DSK 0-050-08-US (09.04) for mounting plates General information s are used in large oil circulation lubrication systems. The task of a flow limiter is to divide up the volumetric flow of the main line
More informationFlow Monitors and Sensors
1-1704-EN Flow Monitors and Sensors for intermittent and circulating centralized lubrication systems Flow monitor Flow sensor Oil-streak sensor Flow monitors/sensors have the task of monitoring the flow
More informationInjection oilers, micro pumps
1-5012-4-EN Injection oilers, micro pumps for minimal quantity metering Injection oiler, 3-port type Injection oiler, 1-port type Micro pump Delivery rates Metering pumps deliver lubricants in a measured
More informationFlow limiter SP/SMB10 Dual flow series
1-00-EN Dual flow series Advantages reliable - Parallel distribution of individual flow quantities - self-regulating metering with pressure balancing valve, thus constant volumetric flows even for different
More informationFlow limiter SP/SMB US
Flow limiter SP/SMB 13... 1-3004-US for installation in the lines of circulating-oil lubrication systems General information Flow limiters are used in large circulating-oil lubrication systems. The task
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...
More informationDC Master 24/ A
USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015
More informationDiaphragm-Gas Sampling Pumps
Diaphragm-Gas Sampling Pumps N 143 ANE N 143 ATE Operating and Installation Instructions Read and observe these Operating and Installation Instructions! N 186.1.2 ANE N 186.1.2 ATE KNF Neuberger GmbH Alter
More informationSP/SMT 1 Flow Divider
1-5017-EN S/SMT 1 Flow Divider with and without inline strainer for circulating-oil or hydraulic systems Introduction The flow divider splits the supplied flow into two equal induvidual flows or into two
More informationSwing Piston Compressors and Vacuum Pumps
Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation
More informationDuplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100
Duplex Filter Pi 211 Nominal pressure 40 bar (570 psi), nominal size 800 and 1100 1. Features High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop through
More informationAngle seat valve with piston actuator VZXA-...-K
Angle seat valve with piston actuator VZXA-...-K Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com
More informationBlock metering device VPB. Block feeder for use in oil or grease lubrication systems
Block metering device VPB Block feeder for use in oil or grease lubrication systems Block metering device VPB Block metering devices or feeders of the VPBM/VPBG series are used in small circulating-oil
More informationDuplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400
Duplex Filter Pi 232 Nominal pressure 25 bar (360 psi), nominal size 800 and 1400 1. Features Duplex filter for gear boxes, lubrication and hydraulic systems Modular system Compact design Weight optimized
More informationSystem description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines
for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines Valve seat lubrication Cylinder lubrication Version 04 Page 2 for cylinder lubrication and valve seat lubrication on
More informationSKF VectoLub, VE1B units
1-4403-EN SKF VectoLub, VE1B units External minimal quantity lubrication, Volumetric metering The emql system SKF VectoLub is a clean and economical alternative for lubricant projection in minimal quantity.
More informationMeter FMT II. Operating manual. original operating manual. Translation of the
Operating manual Meter FMT II Item-No.: 253590000, 253590001, 253590003, 253590004, 253590006, 253590007, 253590008, 253590009, 253590010, 253590011, 253590012, 253590013, 253590020, 253590030, 253590031,
More informationup to 63 A (1 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:
Pump aggregate GMG-B Use: As pump aggregate in central lubrication systems for the delivery of oil, liquid grease or grease 1 or 2 pump outlets up to 2 outlets with progressive distributor flanged-on -
More informationOperating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM
Operating Instructions for Viscosity Compensated Flow Meter / Monitor Model: 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Use in Hazardous Areas...
More informationAngle seat valve with diaphragm actuator VZXA-...-M
Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com
More informationDatasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.
Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount
More informationVHS... Screw Flow Meter
Member of the Group VHS... Screw Flow Meter The normal transmitter with block plug already has a push pull output to serve all NPN or PNP Inputs. It supplies a square wave signal. Those transducers are
More informationCGA Series Automotive Grade Capacitors
CGA Series Automotive Grade Capacitors Type: CGA2 [EIA CC0402] CGA3 [EIA CC0603] CGA4 [EIA CC0805] CGA5 [EIA CC1206] CGA6 [EIA CC1210] Issue date: April 2011 TDK MLCC US Catalog REMINDERS Please read before
More informationOil-free piston compressors KK and piston vacuum pumps KV
Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols
More informationFluid Power Fluid Power
Fluid Power Fluid Power Control Control every move Barksdale State-of-the-Art Solutions Barksdale State-of-the-Art Solutions Today s markets demand flexible and dynamic suppliers of innovative products,
More informationDiaphragm Vacuum Pumps and Compressors
Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N145 AN.18 N145 AT.18 N145 AV.18 N145.1.2 AN.18 N145.1.2 AT.18 N145.1.2 AV.18 KNF Neuberger
More informationLow Pressure Filter Pi 200
Low Pressure Filter Pi 0 Nominal pressure 25/63 bar (360/910 psi), nominal size up to 450 1. Features._ High performance filters for modern hydraulic systems Provided for pipe installation Modular system
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSuction Filter Pi 200
Suction Filter Pi 0 Nominal size up to 90 1. Features High performance filters for modern hydraulic systems Provided for pipe installation Modular system Compact design Minimal pressure drop through optimal
More informationRemote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System
Remote Process Actuation Control System AirLINE - Rockwell 1734 Type 8644 can be combined with... Fully compatible with Rockwell 1734 Point I/O System Combination of Fieldbus, pilot valves and I/O modules
More informationDiaphragm Vacuum Pumps and Compressors
Diaphragm Vacuum Pumps and Compressors N 035 ANE N 035 AN.9 E N 035 ATE N 035 AVE N 035 AV.9 E N 035 SNE N 035 STE N 035 ST.9 E N 035 SVE Operating and Installation Instructions Read and observe these
More informationLow Pressure Filter Pi 200
Low Pressure Filter Pi 0 Nominal pressure 32/63 bar (460/910 psi), nominal size up to 600 1. Features._ High performance filters for modern hydraulic systems Provided for pipe installation Modular system
More informationManually or pneumatically actuated piston pumps
Manually or pneumatically actuated piston pumps Product series Pxx For oil and fluid grease For use in SKF MonoFlex single-line centralized lubrication systems Manually or pneumatically actuated piston
More information3/2-way Solenoid Valve for pneumatics
656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationHAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar
HAZMAT PUMPS TUP, UP, IN EX explosion proof up to 620 l/min, up to 2.0 bar Hazmat pumps TUP acc. to DIN 14 424, protection class EEx II 2 c IIB T3 for inflammable and non-aggressive liquids TUP 2-1 TUP
More informationCompact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN
1-16-EN Compact Units For fluid grease, NLGI grades, Group MKF.1 or.2 l/min MKF1-KW2-2 MKF2-KW3-2 MKF2-KW6-22 These MKFcompact units were developed to supply intermittently operated single-line centralized
More informationPermaglide lead-free The new generation of materials. Technical Product Information
Permaglide lead-free The new generation of materials Technical Product Information Permaglide Lead-free The lead-free generation High performance, environmentally friendly and compliant with environmental
More informationGrease Lubrication Pump FK
1-3033-EN 1-0358-US for use in progressive, single-line and dual-line centralized lubrication systems pplication he FK pump unit is a multi-function piston pump whose modular structure makes it very versatile.
More informationSwing Piston Compressors and Vacuum Pumps
Swing Piston Compressors and Vacuum Pumps NPK 050 NPK 0100 Operating and Installation Instructions Read and observe these Operating and Installation Instructions! KNF Neuberger GmbH Alter Weg 3 D-79112
More informationJM Oil Lubrication Pump SKF MultiFlex multi-line pump units for total loss oil lubrication systems on compressors
1-3007-EN SKF MultiFlex multi-line pump units for total loss oil lubrication systems on compressors General Information The JM oil lubrication pump is a highpressure multiline pump that produces a maximum
More informationOperating Instruction for Flowmonitor. Model: DF-WM
Operating Instruction for Flowmonitor Model: DF-WM 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 5 6. Mechanical Connection...
More informationCompact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:
Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation
More informationGeneral Specifications
General Specifications Model RGL Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in a
More informationThermal flow sensor TFS-35
průmyslová elektronika Thermal flow sensor TFS-35 For sensing limit flow rates of fluid media and for monitoring their temperature. These sensors are intended for installation in pipes, in which the actual
More informationTank top return-line filter Pi 5000
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Tank top return-line filter Pi 5000 Nominal size 160 up to 1000 according to DIN 24550 1. Features
More informationBlock feeder SPVS Used in oil or grease lubrication systems
1-3029-EN Block feeder SPVS Used in oil or grease lubrication systems Block feeders of the SPVS series are used in grease and oil total loss lubrication systems. They are used to either increase the number
More informationExternal Gear Pumps Series F
External Gear Pumps Series F AZPF-... Fixed pumps V = 4.0...28 cm 3 /rev Overview of contents ontents Page General 2 Product overview 3 single pumps 4 multiple pumps 5 rive shaft 6 Front cover 7 Line ports
More informationExternal Gear Pumps Series F
External Gear Pumps Series F RE 10 089/02.07 Replaces: Series F Issue 04.04 AZPF-... Fixed pumps V = 4.0...28 cm 3 /rev Overview of contents ontents Page General 2 Product overview 3 single pumps 4 multiple
More informationGovernor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG
Governor with solenoid valve Air/gas ratio control with solenoid valve All-purpose servo-governor for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500 mbar Outlet pressure
More informationFor grease For application in SKF DuoFlex dual-line centralized lubrication systems
Change-over valves, differential pressure switch ccessories for Dual-line Systems For grease For application in SKF DuoFlex dual-line centralized lubrication systems Change-over valves Hydraulical or electrical
More informationElectromagnetic Buzzers
Electromagnetic Buzzers Pin terminal Without oscillator circuit SD series Issue date: February 2013 Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium,
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationPPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated
1-0107-5-EN PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated These piston pumps are available with two different delivery rate ranges. The pumps can
More informationChain lubrication, accessories Nozzles, oiling-brushes, reservoirs and other accessories for the chain lubrication EN
Nozzles, oiling-brushes, reservoirs and other accessories for the chain lubrication 1-106-EN 16 10,5 16 10,5 ~ ~ Chain lubrication, accessories Oil projection nozzle AC-A Compact design, pinpoint accuracy,
More informationSlide Measuring Instrument GMG 200
GTE Industrieelektronik GmbH Slide Measuring Instrument GMG 200 entsprechend DIN 51131 und EN 13893 GTE Ind.Elektronik Helmholtz Str. 38-40 D-41747 VIERSEN Tel.: ++49 - (0)2162 3703-0 Fax.:++49 - (0)2162
More informationBlock feeder SPVS Used in oil or grease lubrication systems
1-3029-EN Block feeder SPVS Used in oil or grease lubrication systems Block feeders of the SPVS series are used in grease and oil total loss lubrication systems. They are used to either increase the number
More informationRABO Rotary Gas Meter
RABO Rotary Gas Meter Instromet RABO Rotary Gas Meter 02 Elster Instromet Elster Instromet has combined tried and tested product features of their RVG and IRM rotary meter product lines with new developments
More informationLow Pressure Filter Pi 2300
Low Pressure Filter Pi 2300 Nominal pressure 25/40 bar (360/570 psi), nominal size up to 1 Filter elements according DIN 24550 1. Features High performance filters for modern hydraulic systems Provided
More informationLow Pressure Filter Pi 2000
Low Pressure Filter Pi 00 Nominal pressure 32/63 bar (460/900 psi), nominal size up to 400 according DIN 24550 1. Features.. High performance filters for modern hydraulic systems Provided for pipe installation
More informationEB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions
EB 8313-1 EN Translation of original instructions V2001-IP Control Valve Type 3372 0511/0531 Electropneumatic Actuator with Type 3321 Valve Type 3372 Electropneumatic Actuator Edition July 2013 Note on
More informationDuplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300
Duplex Filter Pi 241 Nominal pressure 40 bar (580 psi), nominal size up to 300 1. Features High performance filters for modern hydraulic, lubrication and fuel systems Modular system Compact design Minimal
More informationThermal flow sensor TFS-35
průmyslová elektronika Thermal flow sensor TFS-35 For flow monitoring rates of liquids media and for monitoring of their temperature These sensors are intended for installation in pipes, in which the actual
More informationUser Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)
User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4
More informationAngle seat valve with piston actuator VZXA-...-K
Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts
More informationPTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2
1-4009-EN PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2 The PTEX extruder pumps are pneumatically actuated pumps designed to deliver lubricant under pressure to lubrication
More informationRelated vacuum products
Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CONSUMER TESTING LABORATORIES, INC. 611 Dream Valley Road Rogers, AR 72756 Chessie Koko Phone: 479-636-8782 CHEMICAL Valid To: May 31, 2018 Certificate Number:
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationPSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems
odular feeder PSG product series For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems PSG1 PSG2 PSG3 Fields of application etal-forming machinery
More informationRemote Process Actuation Control System AirLINE - Siemens ET 200S
Remote Process Actuation Control System AirLINE - Siemens ET 200S Type 8644 can be combined with... Fully compatible with Siemens ET 200S Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationAir Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11
Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers
More informationTechnical Report No A Dated
Client: Xiamen Guangpu Electronics Co.,Ltd. Address: No.608, West Lingdou Road, Siming District, Xiamen, China. Attn.: Mr. Zheng Description: LED Panel Light Model No.: GPP0330934WP,GPP0330934WPB Country
More informationVOLUMEC. Valve Position Indicator 02/04
VOLUMEC Valve Position Indicator 02/04 VOLUMEC Valve Position Indicator 02/04 Description Hydraulic manifold HB 4 Gear type Volume counter VCM 02/04 Indicator AVC 02 The Valve Position Indicator VOLUMEC
More informationSolenoid valves VZWP, servo-controlled
Key features and overview Function The solenoid valve VZWP-L- is a servo-controlled 2/2-way valve with solenoid coil. The solenoid valve is closed when de-energised. When energised, the differential pressure
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationPiston Distributors, Metering Units
Piston Distributors, Metering Units 1-5001-US For single-line total-loss lubrication systems Group 320 0.01-0.16 ccm Group 321 0.03-0.1 ccm Group 340 0.01-0.16 ccm Group 350 0.1-0.6 ccm Group 390 0.2-1.5
More informationProportional pressure regulators VPPX
Features LED indicators Plug socket with cable Venting at both ends Manifold block Sub-base valve Angle bracket Individual valve H-rail mounting repositionable by 180 Compressed air supply at both ends
More informationChain lubrication, accessories
1-106-EN Chain lubrication, accessories Nozzles, oiling brushes, reservoirs and other accessories for chain lubrication Oil projection nozzle AC-A Compact design, pinpoint accuracy, and high temperature
More informationElster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information
Connected Industrial Elster RABO Highly Accurate Rotary Gas Meter Applications Honeywell Elster has combined tried and tested product features of their RPM and IRM rotary meter product lines with new developments
More informationMicro Diaphragm Gas Sampling Pumps
Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP830K_DC-M HP NMP830.1.2K_DC-M HP NMP830K_DC-B HP NMP830.1.2K_DC-B HP NMP830K_DC-B4 HP NMP830.1.2K_DC-B4 HP You
More informationHYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm
HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm and piston accumulators. They guarantee optimum use
More informationElectromagnetic Buzzers
Electromagnetic Buzzers SMD Without oscillator circuit SDR series Issue date: August 2007 Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury,
More informationNIDEC COPAL ELECTRONICS CORP.
1 / 8 Specifications Model No. TF037F-2000-F Issuing Date Aug.1, 2017 1.Scope This document applies to Blower TF037F-2000-F (hereinafter referred to as "PRODUCT"), a product of NIDEC COPAL ELECTRONICS
More informationTank top return-line filter Pi 5000
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Tank top return-line filter Pi 5000 Nominal size 160 up to 00 according to DIN 24550 1. Features
More information