Safety valves direct, pilot operated and cartridge execution

Size: px
Start display at page:

Download "Safety valves direct, pilot operated and cartridge execution"

Transcription

1 Table E-3/E Safety valves direct, pilot operated and cartridge execution with inductive position or proximity switches conforming to Machine Directive 6/4/CE DHI-6*/FI LIDA-343*/FV LIFI-34*/NC DKE-6*/FV LIDAS-343*/FV DPHI-7*/FV Safety valves are designed to fulfil the safety criteria imposed to machine manufacturers by the European Machine Directive. They are CE marked and certified by TÜV, in accordance with the technical safety requirements provided in the Machine Directive 6/4/CE but not included in the safety components of annex IV. In addition to the normal hydraulic function they are equipped with inductive or proximity switches; with the on/off switch indicates the position of the spool/poppet of the valve. These valves are normally used to cut off the hydraulic power line in case of emergency condition, thus avoiding dangerous movements of the machines actuators. By checking the switch status, corresponding to open or intercepted hydraulic line, the machine controller can perform the safety function. Two versions are available: - FI inductive proximity switch ; - FV inductive position switch (double contacts) ; see section 4 for technical characteristics. Safety valves are available in direct, piloted and cartridge executions, with same hydraulic and electric characteristics of standard products from which they are derived. Typical application is on vertical and horizontal presses to shut off the fluid energy to one or more actuators as a consequence of the opening of the machine gate or as a consequence of an emergency stop command. For details about the applicable EN standards, see catalog on line, section P, table P4. RANE OF VALVE S MODELS Valve code Size Description DC solenoids AC solenoids Switch type /FI /FV /FI /FV DHI-6 6 direct operated solenoid valves, on-off, single solenoid DHI-7 6 direct operated solenoid valves, on-off, double solenoid DHE-6 6 direct operated solenoid valves, on-off, single solenoid DHE-7 6 direct operated solenoid valves, on-off, double solenoid DKE-6 direct operated solenoid valves, on-off, single solenoid DKE-7 direct operated solenoid valves, on-off, double solenoid DPH* ; 6; 5 piloted operated solenoid valves, on-off, with DHE or DHI pilot LIFI 6 5 intermediate elements with cartridge, to be coupled with a specific cover LIDA(H) 6 5 on-off cartridges LIDAS(H) 6 5 on-off active cartridges E

2 MODEL CODE OF DIRECT OPERATED SAFETY SOLENOID VALVES DHI 63 / /A / FV * - X ** 4DC /* omit for NBR (mineral oil & water glycol) Type of solenoid valve DHI, DHE = direct, size 6 (see tab. E, E5) DKE = direct, size (see tab E5) Series number Size ISO 44 = size 6 (DH*) = size (DK*) Voltage code, see section 5 Valve configuration, see section 3 6 = single solenoid, central plus external position, spring centered 63 = single solenoid, external positions, spring offset 67 = single solenoid, external plus central position, spring offset 7 = double solenoid, 3 positions, spring centered 75 = double solenoid, external positions, with detent X = without connector, see section 5 for available connectors, to be ordered separately Electrical signal (only for FI version): /NC = electric contact is closed when the valve is de-energized /NO = electric contact is open when the valve is de-energized Spool type, see section 3 Type of switch: FI = inductive proximity switch FV = inductive position switch (double contact) note: see section for valve model and switch type combination Options (), see section 4 Option WP not permitted for safety valves () DKE/F* are always provided with Y drain port 3 CONFIURATIONS and SPOOLS (representation according to ISO 9-) Configurations Spools 6 6/A Configurations / 9 / only for DH*/FI only for DH*/FI 63/A 8 / 7 only for DH* 4 67/A (for valves /FV) 49 only for DH*/FI 7 (for valves /FI) only for DH* 75 (for DH*/FI) only for DH*/FI not for DH*/FV not for DH*/FV 58 /9 /3 /7 5/7 (4) () () () 6/7 7/7 (3) (3) () only for DKE-6/3/* () only for DH*-6* and DKE-63* not available version /A / only for DH* 4 Spools 75 (for DH*/FV, DKE/FV, DK*/FI) / (3) only for DH*-6*, not available version /A (4) only for DHI-7/9/FI DHE-7/9/FI DKE-7/9/FI NOTES 4. Option A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A. 4. Special shaped spools for DHI and DHE - spools type and 3 are also available as / and 3/ with restricted oil passages in central position, from user ports to tank. - spools type, 4, 5 and 58 are also available as /, 4/8, 5/ and 58/. They are properly shaped to reduce water-hammer shocks during the swiching. - spools type, /, 3, 8 are available as P, /P, 3P, 8P to limit valve internal leakages. - Other types of spools can be supplied on request. 4.3 Special shaped spools for DKE - spools type and 3 are also available as / and 3/ with restricted oil passages in central position, from user ports to tank. -spools type is also available as /, properly shaped to reduce the water-hammer shocks during the switching. - spool type /9 has closed center in rest position but it avoids the pressurization of A and B ports due to the internal leakages. - other types of spools can be supplied on request.

3 5 MODEL CODE of pilot operated safety solenoid valves DPH Two stage directional control valve I - 7 /A /FV X 4DC ** /* Solenoid pilot valve: I = DHI for AC and DC supply with CURUS certified solenoids E = DHE for AC and DC supply, high performances with CURUS certified solenoids Valve size: = = 6 4 = 5 Series number Voltage code, see section 5 omit for NBR (mineral oil & water glycol) Valve configuration, see section 6: 6 = single solenoid, center plus external position, spring centered 63 = single solenoid, external positions, spring offset 67 = single solenoid, center plus external position, spring offset 7 = double solenoid, 3 positions, spring centered 75 = double solenoid, external positions, with detent X = without connector, see section 5 for available connectors, to be ordered separately type of switch FV = inductive position switch (double contact) Spool type, see section 6 Options, see section 7 option WP not permitted for safety valves 6 CONFIURATIONS and SPOOLS (representation according to ISO 9-) Configurations Spools Configurations Spools 6 6/A not for DPH / /A / 67/A 9 not for DPH- not for DPH- not for DPH- not for DPH not for DPH- not for DPH- not for DPH- not for DPH- 75 / not for DPH not for DPH- not for DPH- not for DPH- Note: see also section 7. for special shaped spools 58 7 NOTES 7. Options A = Solenoid mounted at side of port A of main body (only for single solenoid valves). In standard version, solenoid is mounted at side of port B. D = Internal drain (standard configuration is external drain) E = External pilot pressure (standard configuration is internal pilot pressure). R = Pilot pressure generator (4 bar on port P - not for DPH*-) FUNCTIONAL SCHEME (config. 7) example of switching control options Devices for main spool switching control and to reduce the hydraulic shocks at the valve operation H = Adjustable chokes (meter-out to the pilot chambers of the main valve). H9 = Adjustable chokes (meter-in to the pilot chambers of the main valve). L9 = (only for DP- and DP-4) plug with calibrated restictor in P port of pilot valve Plug code: plug-a ø, mm for DP- plug-5a ø,5 mm for DP-4 7. Special shaped spools - spools type and 3 are also available as / and 3/ with restricted oil passages in central position, from user ports to tank. - spools type, 4, 5, 58, 6 and 7 are also available as /, 4/8, 5/, 58/, 6/ and 7/ that are properly shaped to reduce water-hammer shocks during the switching. option H, H9 option L9 Shaped spool availability / 3/ / 4/8 5/ 58/ 6/ 7/ DPH*- DPH*-, DPH*-4

4 8 SAFETY VALVES IN CARTRIDE EXECUTION (MADE BY INTERMEDIATE ELEMENT AND COVER) 8. MODEL CODE FOR INTERMEDIATE ELEMENT INCLUSIVE OF THE CARTRIDE LIF I 5 4 /NC ** /* Intermediate element (with poppet position detector) including the cartridge omit for NBR (mineral oil & water glycol) Type of switch: I = inductive proximity switch Series number Size (ISO 7368), the same of the cover - see section 6; 5; 3; 4; 5 Other dimensions available on request 4 /NC = closed contact with poppet in resting position Type of poppet, see tab. H3 for Q/Δp diagrams 4 = With damping nose, area ratio :, 43 = With damping nose, area ratio : (for size 6 and 5) :,6 (for size 3, 4 and 5) Spring cracking pressure: =,3 bar for poppet 4;,6 bar for poppet 43 =,5 bar for poppet 4 3 = 3 bar for all poppets 6 = 5,5 bar for all poppets Note: in these safety valves the cartridge and the intermediate element with poppet position detector cannot be separated. 8. COVER MODEL CODE LID A Cover according to ISO 7368 to be coupled with LIFI safety valves / F E -I X 4DC ** /* /* Special execution of the calibrated plugs in the pilot channels (see tables H3, H4) Cover type, see section 9 for hydraulic configuration: A = direct pilot B = with shuttle valve for pilot selection; EW* = with solenoid valve for pilot selection BH** = as EW* but with shuttle valve for pilot selection; Series number omit for NBR (mineral oil & water glycol) Size = 6; = 5; 3 = 3; 4 = 4; 5 = 5; Other sizes available on request Voltage code (only for LIDBH** and LIDEW*) see section Only for LIDBH** and LIDEW*: X = without connector, to be order separately see section 5 F = prearranged for coupling with LIFI cover Type of pilot solenoid valve (only for LIDBH** and LIDEW*): -I = DHI for AC and DC supply with CURUS certified solenoids -E = DHE for AC and DC supply high performances, with CURUS E = with external attachment X (/4 AS) and underneath port X plugged certified solenoids According to the machinery safety requirements, in particular applications at least two safety valves (redundancy) will be provided (the first one leak free type). For valve type LIDB, LIDEW (in the configuration with external pilot line) Atos can supply leak free poppet type directional pilot valves type DLOH-3*. Consult our technical office for detailed information. 5 9 HYDRAULIC SYMBOLS (the following symbols shown the covers function coupled with safety valve type LIFI) LIDEW-* LIDEW-* LIDEW-* LIDEW4-* LIDEW5-* LIDEW6-* LIDA LIDB-* LIDBHA-* LIDBHC-* LIDBHA-* LIDBHC-* E

5 MODEL CODE OF SAFETY VALVES IN CARTRIDE EXECUTION (INTERAL DESIN COVER) LIDA Safety cartridge valve according to ISO 7368 optional pilot valve: - = omit if not required H = with N 6 pilot valve H / FV / I X 4DC ** /* omit for NBR (mineral oil & water glycol) Series number HYDRAULIC SYMBOLS OF LIDA LIDA-**43/FV Size: poppet type: 43 = with damping nose, area ratio : (size 6 and 5) :,6 (size 3,4 and 5) Only for LIDAH X = Voltage code see section Only for LIDAH without solenoid connectors to be ordered separately (see tab. K5) 5 spring cracking pressure: =,6 bar 3 = 3 bar 6 = 5,5 bar Type of switch: FV = inductive position switch (double contact) Pilot solenoid valve -I = DHI for AC and DC supply, with CURUS certified solenoids -E = DHE for AC and DC supply, high performances, with CURUS certified solenoids LIDAH-**43/FV MODEL CODE OF SAFETY VALVES IN CARTRIDE EXECUTION (INTERAL DESIN COVER) Pilot control - = without pilot solenoid valve H = with pilot solenoid valve LIDAS H / FV I X 4DC ** On-off active cartridges, according to ISO 7368 series number /* omit for NBR (mineral oil & water glycol) Size: Poppet type: 43 (with dumping nose) Only for LIDASH Voltage code, see section Only for LIDASH X = without connector, see section = spring cracking pressure 3 bar Pilot valve only for LIDASH: FV = inductive proximity switch (double contact) -I = DHI for AC and DC supply with CURUS certified solenoids -E = DHE for AC and DC supply high performances, with CURUS certified solenoids 3 HYDRAULIC SYMBOLS OF LIDAS 4 STATUS OF OUTPUT SINALS for cartridge valves LIFI, LIDA*/FV and LIDAS*/FV A: overlapping stroke B: damping stroke According the criteria of safety specifications, the poppet position signal must change its status inside the overlapping stroke (before the effective valve opening). stroke FLOW SINAL leakage LIDAS/FV LIDASH-*/FV flow Q 5 VOLTAE CODE Valve DHI DPHI LIDAH-I LIDASH-I External supply nominal voltage ± % 6 DC 9 DC DC 4 DC 8 DC 4 DC 8 DC 48 DC DC 5 DC DC 4/5 AC 4/6 AC 48/5 AC 48/6 AC /5 AC /6 AC 3/5 AC 3/6 AC /5 AC /6 AC 3/5 AC 3/6 AC Voltage code 6 DC 9 DC DC 4 DC 8 DC 4 DC 8 DC 48 DC DC 5 DC DC 4/5/6 AC () 48/5/6 AC () /5/6 AC () /6 AC 3/5/6 AC () 3/6 AC RC 3RC Type of Power connector consumption 666 or W 6 VA 4 VA 35 VA 4 VA 35 VA Valve DHE DPHE LIDAH-E LIDASH-E DKE External supply nominal voltage ± % DC 4 DC 4 DC 8 DC 48 DC DC 5 DC DC /5 AC 3/5 AC 5/6 AC 3/6 AC /5 AC /6 AC 3/5 AC 3/6 AC DC 4 DC DC DC /5/6 AC 3/5/6 AC /5/6 AC 3/5/6 AC Voltage code DC 4 DC 4 DC 8 DC 48 DC DC 5 DC DC /5/6 AC 3/5/6 AC 5/6 AC 3/6 AC RC 3 RC DC 4 DC DC DC /5/6 AC 3/5/6 AC DC DC Type of connector 666 or or Power consumption 3 W 58 W 68 W 3 W 36 W 85 VA 36 W

6 6 MAIN CHARACTERISTICS Installation position Any position Subplate surface finishing Roughness index Ra,4 - flatness ratio,/ (ISO ) Ambient temperature Fluid from - C to +7 C Hydraulic oil as per DIN ; for other fluids see specific model code Recommended viscosity 5 mm /s at 4 C (ISO V 5 ) Fluid contamination class ISO 446 class /9/6 NAS 638 class, in line filters of 5 μm (β _>75 recommended) Fluid temperature - C +6 C (standard seals) - C +8 C (/PE seals) Flow direction As shown in the symbols of tables 3 Operating pressure DHI DHE DKE DPH* LIFI LIDA/FV LIDAS(H) P, A, B = 35 bar T = bar (version /FI); bar (version /FV) P, A, B = 35 bar T = bar (version /FI); bar (DC solenoid - version /FV); 6 bar (AC solenoid - version /FV) P, A, B = 35 bar T = (with Y port not connected to tank) bar (version /FI); bar (DC solenoid - version /FV); bar (AC solenoid - version /FV) T = (with Y port drained to tank) 5 bar P, A, B, X = 35 bar T = 5 bar for external drain (standard) T with internal drain (option /D) = bar DPHI; bar DPHE (DC); 6 bar DPHE (AC) Ports Y = bar Minimum pilot pressure for correct operation is 8 bar A, B, X = 35 bar Y = see port T of selected pilot valve (DHI or DHE) A, B, X = 35 bar - Y = bar (for LIDASH) Maximum flow DHI DHE DKE DPH* LIFI (at P = 6 bar) LIDA/FV (at P = 6 bar) LIDAS(H) (at P =5 bar) 6 l/min see technical table E, section 8, operating limits 8 l/min see technical table E5, section 9, operating limits 5 l/min see technical table E5, section 9, operating limits DPH*-: 6 l/min; DPH*-: 3 l/min; DPH*-4: 7 l/min; poppet 4 size 6 = 5 l/min; size 5 = 3 l/min; size 3 = 6 l/min; size 4 = 5 l/min; size 5 = l/min poppet 43 size 6 = 3 l/min; size 5 = 3 l/min; size 3 = 48 l/min; size 4 = 94 l/min; size 5 = 5 l/min poppet 43 size 6 = 3 l/min; size 5 = 3 l/min; size 3 = 48 l/min; size 4 = 94 l/min; size 5 = 5 l/min poppet 43 size 6 = l/min; size 5 = 4 l/min; size 3 = 6 l/min; size 4 = 3 l/min; size 5 = l/min 6. Coils characteristics Insulation class H (8 C) for all valves with DC coils and DHI, DPHI with AC coils F (55 C) for DHE, DKE, DPHE with AC coils Due to the occuring surface temperatures of the solenoid coils, the European standards EN ISO 373- EN ISO 443 must be taken into account Connector protection degree IP 65 Relative duty factor % Supply voltage and frequency See electric feature Supply voltage tolerance ± % Certification (only DHI, DKER, DPHI) CURUS North American standard WARNIN: the inobservance of following prescriptions invalidates the certification and may represent a risk for personnel injury Safety valves must be installed and commissioned only by qualified personnel Safety valves must not be disassembled The inductive proximity switch or the position switch can be adjusted only by the manufacturer Valve s components cannot be interchanged The valves must operate without switching shocks and spool / poppet vibrations E

7 7 STATUS OF OUTPUT SINAL FOR DIRECTIONAL VALVES Configuration 6 Configuration 67 ISO 44 size 6 and HYDRAULIC CONFIURATION Configuration 7 Configuration 63 Configuration 75 DH*, DPH* DK* high level SINAL S () low level high level () () () SINAL SA () low level high level () SINAL SB () low level () Diagrams show the behaviour of the output signal for inductive switches type FI/NO. For inductive switches type FI/NC the behaviour is opposite (high level signal instead of low level signal and viceversa) () According the criteria of safety specifications, the spool position signal must change its status during the intermediate position between two hydraulic configurations. Note: FV versions can be electrically wired by the customer as NO or NC and then the status of the output signal will be in accordance to the selected configuration 8 TECHNICAL CHARACTERISTICS OF INDUCTIVE PROXIMITY AND POSITION SWITCHES Type of switch Supply voltage Ripple max Max current Power consumption Voltage drop Max switching frequency Max peak pressure Mechanical life Switch logic 9 inductive proximity /FI - DH* and DK* position switch /FV inductive proximity - only for LIFI virtually infinite PNP 3 5 8,5 35 [V] [%] [ma] [ma] [V] [Hz] [bar] CONNECTIN SCHEMES OF INDUCTIVE PROXIMITY AND POSITION SWITCHES DH*/FI single solenoid / double solenoid (dotted line) /FV (all valves) single solenoid /FV (all valves) double solenoid DKE*/FI single solenoid DKE*/FI double solenoid LIFI Connector type 345 Connector type ZBE-6 Connector type ZBE-6 Connector type 666 Connector type 664 Connector type BKS-B--4-3 = output signal sol.a = supply +4 VDC 3 = output signal sol.b T = ND black = output signal brown = supply +4 VDC blue = ND CABLE LENHT = 3 m NO = output signal S (sol.a for double solenoid) = supply +4 VDC 3 = not connected (output signal sol.b for double solenoid) 4 = ND NC = supply +4 VDC = output signal NC 3 = ND 4 = output signal NO sol. A sol. B = supply +4 VDC = output signal sol.b 3 = ND 4 = output signal sol.a = output signal S = supply +4 VDC T = ND NOTE: the /FI switch an /FV position switch are not provided with a protective earth connection CONNECTORS FOR INDUCTIVE PROXIMITY AND POSITION SWITCHES The connector for proximity switch and mechanical microswitches are always supplied with the valves VALVE TYPE CONNECTOR TYPE protection degree DHI/FI, DHE/FI 345 DHI/FV, DHE/FV, DKE/FV ZBE-6 DKE/FI 666 (single solenoid) (double solenoid) DPH*/FV ZBE-6 LIDA*/FV ZBE-6 LIFI BKS-B--4-3 Special connector with 3 mt molded cable (included) IP67 LIDAS*/FV ZBE-6 NOTE: valve type DKE*/FI double solenoid, configuration 75, use connector 666

8 DIMENSIONS for DH* SOLENOID SAFETY VALVES [mm] ISO 44: 5 Mounting surface: Fastening bolts: 4 socket head screws: M5x5 class.9 (DHI, DHU) M5x3 class.9 (DHE, DHER) Tightening torque = 8 Nm Seals: 4 OR 8 Ports P,A,B,T: Ø = 7.5 mm (max) P = PRESSURE PORT A, B = USE PORT T = TANK PORT For the max pressures on ports, see section 6 DHI-6*/FI (DC, AC) DHI-7*/FI (DC, AC) dotted line kg,6 (one solenoid) kg,9 (two solenoids) DHI-6*/FV (DC, AC) kg,7 DHE-6*/FI (DC) DHE-7*/FI (DC) dotted line DHE-6*/FI (AC) DHE-7*/FI (AC) dotted line kg,85 (one solenoid) kg, (two solenoids) kg,85 (one solenoid) kg, (two solenoids) DHE-6*/FV (DC) DHE-6*/FV (AC) kg,95 kg,8 DHE-7*/FV (DC) max kg, E

9 DIMENSIONS of DKE SOLENOID SAFETY VALVES [mm] DKE-6*/FI (DC) DKE-7*/FI (DC) dotted line DKE-6*/FI (AC) DKE-7*/FI (AC) dotted line kg 4,4 (one solenoid) kg 5,8 (two solenoids) ISO 44: 5 Mounting surface: (without port X) Fastening bolts: 4 socket head screws M6x4 class.9 Tightening torque = 5 Nm Seals: 5 OR 5. OR 8 Ports P,A,B,T: Ø =.5 mm (max) Ports Y: Ø = 5 mm P = PRESSURE PORT A, B = USE PORT T = TANK PORT Y = DRAIN PORT For the max pressures on ports, see section 6 kg 3,7 (one solenoid) kg 4,4 (two solenoids) DKE-6*/FV (DC) DKE-7*/FV (DC) kg 4,4 kg 5,9 DKE-6*/FV (AC) kg 3,8 3 DIMENSIONS of DPH* PILOT OPERATED SAFETY VALVES [mm] DPH*-/FV switch position for configuration 6, 63/A, 67/A switch position for configuration 6/A, 63, 67 max ISO 44: 5 Mounting surface: (without port X) Fastening bolts: 4 socket head screws M6x4 class.9 Tightening torque = 5 Nm Seals: 5 OR 5. OR 8 Ports P,A,B,T: Ø =.5 mm (max) Ports Y: Ø = 5 mm kg 7. (one solenoid) kg 7,8 (two solenoids) Note: for configurations 7 and 75 the switch position in on both sides of the valve P = PRESSURE PORT A, B = USE PORT T = TANK PORT Y = DRAIN PORT For the max pressures on ports, see section 6

10 DPH*-*/FV ISO 44: 5 Mounting surface: Fastening bolts: 4 socket head screws Mx5 class.9 Tightening torque = 7 Nm socket head screws M6x45 class.9 Tightening torque = 5 Nm Diameter of ports A, B, P, T: Ø = mm; Diameter of ports X, Y: Ø = 7 mm; Seals: 4 OR 3, OR 43 P = PRESSURE PORT A, B = USE PORT T = TANK PORT X = EXTERNAL OIL PILOT PORT Y = DRAIN PORT For the max pressures on ports, see section 6 kg 9,6 (one solenoid) kg,5 (two solenoids) DPH*-4*/FV ISO 44: 5 Mounting surface: Fastening bolts: 6 socket head screws Mx6 class.9 Tightening torque = 5 Nm Diameter of ports A, B, P, T: Ø = 4 mm; Diameter of ports X, Y: Ø = 7 mm; Seals: 4 OR 4, OR 356 P = PRESSURE PORT A, B = USE PORT T = TANK PORT X = EXTERNAL OIL PILOT PORT Y = DRAIN PORT For the max pressures on ports, see section 6 max max switch position for configuration 6/A, 63, 67 switch position for configuration 6, 63/A, 67/A Note: for configurations 7 and 75 the switch position in on both sides of the valve switch position for executions 6/A, 63, 67 switch position for executions 6, 63/A, 67/A Note: for configurations 7 and 75 the switch position in on both sides of the valve kg 7,7 (one solenoid) kg 8,6 (two solenoids) E

11 4 DIMENSIONS of LIFI SAFETY COVERS [mm] A B H H H L P LIFI-6 54, LIFI-5 54, LIFI LIFI-4 4 3, LIFI Note: for cover interface and cavity dimensions ISO 7368, see table P6 5 EXAMPLES OF LIFI COUPLED WITH OTHER COVERS (examples in size 3) LIDBHA-3/F-IX 4DC LIDB-3/F LIDEW-3/F-IX 4DC LIDA-3/F LIFI-34*/NC LIFI-34* LIFI-34*/NC LIFI-34* 6 INSTALLATION DIMENSIONS of LIDA*/FV and LIDAS*/FV SAFETY CARTRIDES [mm] (examples in size 3) LIDA-*/FV, LIDAH-*/FV Connector ZBE-6 supplied with the valve LIDAS-*/FV, LIDASH-*/FV Connector ZBE-6 supplied with the valve A A Pilot valve only for LIDAH-*/FV Pilot valve only for LIDASH-*/FV Cover interface UNI ISO 7368 x y B BxB B 86 max B BxB B 86 max Note: for cover interface and cavity dimensions ISO 7368, see table P6 Size 6 5 LIDA LIDAH LIDAS LIDASH Seal Fastening bolts Tightening torque (Nm) A B B B A B B B A B B B A B B B LIDA OTHER LIDA LIDAH LIDAS, LIDASH 5 65x x x OR 8 OR 8 4 M8x5 4 M8x OR 8 OR 8 4 Mx55 4 Mx8 4 M8x Mx OR 43 OR 43 4 M6x7 4 M6x7 4 M6x OR 5 OR 5 4 Mx8 4 Mx8 4 Mx OR 5 OR 5 4 Mx8 4 Mx8 4 Mx8 6 4/4

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE www.atos.com Table TE-/E Complementary safety valves with /FC mechanical microswitches confming to Machine Directive 6/4/CE -6*/FC -6*/FC DPHI-7*/FC These valves are provided with FC mechanical microswitch

More information

Safety cartridge valves with poppet position monitoring

Safety cartridge valves with poppet position monitoring Table EY/E Safety cartridge valves with poppet position monitoring ISO standard, onoff, poppet type, conforming to Machine Directive //EC certified by LIFI*/NC 1 RNE OF VLVE S MODELS LID*/FV Inductive

More information

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32 www.atos.com Table E0857/E Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32 DPHE471*/H Spool type, two stage directional valves with solenoids certified according

More information

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves

More information

Safety directional valves with spool position monitoring

Safety directional valves with spool position monitoring Table EY0100/E Safety directional valves with spool position monitoring Onoff, direct operated, conforming to Machine irective 2006/42/E certified by ody Spool Inductive proximity sensor FI Inductive position

More information

Solenoid directional valves type DPHI, DPHU

Solenoid directional valves type DPHI, DPHU www.atos.com Table E0805/E Solenoid directional valves type, two stage, ISO 4401 size 10, 16, 25 and 32 37**/HM..... and are spool type, two or three position directional two stage solenoid valves designed

More information

SOLENOID DIRECTIONAL VALVE

SOLENOID DIRECTIONAL VALVE SOLENOID DIRECTIONAL VALVE type DHE direct operated, high performances, ISO 4401 dimensione 06 Spool type, two or three position direct operated valves with high performance threaded solenoids certified

More information

ISO cartridge valves type LIDEW* and LIDBH*

ISO cartridge valves type LIDEW* and LIDBH* wwwatoscom Table H00/E ISO cartridge valves type LIDEW* and LIDH* directional control, ISO 78 size from to 00, high flow, Pmax bar LIDEWE Y X Y X Functional cover Poppet Sleeve Spring Pilot slenoid valve

More information

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32 www.atos.com able E0854/E Solenoid al valves DHI, DHE, DHER two stage, ISO 440 size 0, 6, 5 and 3 DHI, DHE and DHER are spool, two or three position, two stage al solenoid valves. hey are operated by a

More information

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32 Table C0701/E Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32 AGIRR20/***/V AGIU10/11...E Two stage pressure control valves with balanced poppet

More information

Pressure relief valves type ARAM

Pressure relief valves type ARAM www.atos.com Table C04521/E Pressure relief valves type ARAM two stage, in line mounting G 3/4" and G 1 1 /4" threaded ports ARAM20/20...E ARAM32.../V ARAM are two stage pressure relief valves with balanced

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

ISO cartridge valves type LIM*, LIRA, LIC*

ISO cartridge valves type LIM*, LIRA, LIC* Table H000/E ISO cartridge valves type LIM, LIRA, LIC Pressure controls: relief, reducing, compensator, ISO 7368 size from 6 to 80 Pmax 40 bar Pressure control valves in ISO cartridge design specific for

More information

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40 www.atos.com Table TF/E Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7 sizes from to connector MODEL CODE FOR COVERS Proportional pressure reducing cartridge valves A = without

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63 Table H004/E ISO cartridge valves type LIDD and LIQV Flow control, ISO 78 sizes LIDD LIQV/K LIDD and LIQV are flow control valves not compensated, in ISO cartridge design, made by a functional cover and

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25 wwwatoscom Table F70-0/E Proportional directional valves type DPZO-A* two stage without position transducer, ISO 440 sizes 0, 6 and 5 Valve body Main stage Spool Pilot valve Integral electronics MODEL

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification able C-1/E Replaces E1-2/E Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - AE or IECEx certification Main poppet Valve main body Mechanical pressure limiter Cover

More information

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06 www.atos.com Table TF040-4/E Proportional pressure reducing valves type DHRZO direct operated, ISO 440 size 06 A DHRZO are 3 way, proportional pressure reducing valves, direct operated, with standard ISO

More information

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND 48 900/103 ED LC* LP* LOGIC ELEMENTS CARTRIDGE VALVES ISO 7368 - DIN 24342 COVERS FOR CARTRIDGE VALVES ND 16-25-32-40-50 p max 420 bar Q max (see performance ratings table) OPERATING PRINCIPLE Logic elements

More information

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W www.atos.com Table TE137obs/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification UL certified valves are obsolete

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368 Table EX5/E Replaces E/E E5/E Exproof ISO cartridge valves multicertification TEX, IECEx, EC or North merican certification CULUS directional control, ISO 7 Functional cover Poppet Sleeve Spring Ex proof

More information

Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 4401 size 06 and 10 www.atos.com Table F65-/E Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 440 size 06 and 0 Valve body Spool Proportional solenoid Position transducer

More information

solenoid valves

solenoid valves electrohydraulic solenoid valves www.atos.com tos... a leading manufacturer of solenoid valves many millions of valves operate today worldwide tos valves features: shell-moulding castings machined by transfer

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25 wwwatoscom Table F70-9/E Proportional directional valves type DPZO-* two stage out position transducer, ISO 0 sizes 0, 6 and 5 Communication plastic connector, see section 5 DPZO-E-5 DPZO-ES-PS-7 (dotted

More information

Proportional relief valves

Proportional relief valves www.atos.com Table FS007-1/E Proportional relief valves digital, direct operated, open loop Valve body Proportional solenoid Spring Poppet Integral electronics US connector Fieldbus connector Main connector

More information

Proportional Pressure Relief Valve Series RE*T

Proportional Pressure Relief Valve Series RE*T Characteristics The pressure relief valve series RE*T have a proportional solenoid operated pilot stage with integrated electronics and a cartridge main stage. Features Pilot-operated pressure relief valve

More information

Proportional reducing valves

Proportional reducing valves www.atos.com Table FS015-0/E Proportional reducing valves digital, direct operated, open loop Valve body Proportional solenoid Spool Integral electronics Main connector Fieldbus connector US connector

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact: Solenoid operated EEx d IIC T6 Description of the Valve Directional control valves direct the flow in various directions (P A with 2/2 valves and P A // A T) with 3/2 valves. Available as 2/2 and 3/2 valves,

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10 Table TE030-0/E Solenoid directional valves Pmax 40 bar direct operated, ISO 440 size 06 and size 0 HEP-07*-** HEP; KEP, direct operated solenoid valves with max pressure up to 40 bar for heavy duty applications

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

Directional cartridge valve tight on both sides type 2URED6 3

Directional cartridge valve tight on both sides type 2URED6 3 APPLICATION Directional cartridge valve type URED6 is intended for control direction of fluid flow, causing particular movement direction or stops a receiver (cylinder or hydraulic motor). The directional

More information

Q max (see specifications table)

Q max (see specifications table) 41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Proportional reducing valves

Proportional reducing valves www.atos.com Table FS070-1/E Proportional reducing valves digital, pilot operated, open loop, subplate or modular mounting Main spool Proportional pilot relief valve Pilot flow compensator Integral electronics

More information

Examples 3/2-way valve A T NO: Symbol

Examples 3/2-way valve A T NO: Symbol 1/1 Hauhinco-3_2-way valve_b1_dn3-25_pn320_pn500_x,y-intern water s 01/2016 3/2-way valve B1 X,Y - DN3 DN25 PN320, PN500 Features: Hydraulically actuated directional seat valve controlling liquid media.

More information

2/2 Solenoid Cartridge Valve, Size 10

2/2 Solenoid Cartridge Valve, Size 10 2/2 Solenoid Cartridge Valve, Size 1 Q max = 8 l/min, p max = 3 bar Seat-valve shut-off, two-stage, monitored operating position 1 Description With integral electronic monitoring of operating position

More information

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation

More information

Proportional reducing valves

Proportional reducing valves www.atos.com Table FS050-1/E Proportional reducing valves digital, pilot operated, open loop Valve body Main spool Pilot flow compensator Integral pressure limiter Pilot relief valve Integral electronics

More information

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer RE 29076/12.05 1/24 Type 4WRBKE Nominal size (NG) 10, 16, 27, 35 Unit series 1X

More information

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10 www.atos.com Table F60-8/E Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 440 size 06 and 0 AES execution included in this table is available

More information

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback RA 29024/01.05

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) 4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29121 Edition: 2014-01 Size 6 Component series 3X Maximum operating pressure

More information

Proportional relief valves with integral pressure transducer

Proportional relief valves with integral pressure transducer www.atos.com Table FS067-/E Proportional relief valves with integral pressure transducer digital, pilot operated, closed loop high performances, rugged design Valve body Poppet Proportional solenoid Integral

More information

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum

More information

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES CONTINENTAL HYDRAULICS VSD*S MONITORED DIRECTIONAL CONTROL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSD*S MONITORED DIRECTIONAL CONTROL VALVES

More information

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Type DREBE6X Nominal size (NG) 6 Unit series 1X Maximum working pressure P 315 bar, T 250 bar

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...

More information

Directional servo-valve of 4-way design

Directional servo-valve of 4-way design Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (0) 426-54 www.cmafh.com Directional servo-valve of 4-way design Type 4WSE3E 32 Size 32 Component series 5X Maximum

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE) Proportional directional valve, pilot-operated, with integrated electronics (OBE) Type WFCE RE 943 Edition: 7- Replaces: 6- Size 6 5 Component series X Maximum operating pressure 4 bar Maximum flow 5 l/min

More information

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE) 4/ directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE) RE 977/.1 Replaces: 1.9 1/16 Type 4WRVE 1...7, symbols V, V1 Sizes 1, 16, 5, 7 Component series

More information

Servo solenoid valves with positive overlap and on-board electronics

Servo solenoid valves with positive overlap and on-board electronics Servo solenoid valves with positive overlap and on-board electronics RE 29089/01.05 1/22 Replaces: 05.04 Type 4WRLE 10...35, symbols E./W. Nominal size 10, 16, 25, 35 Unit series 3X Maximum working pressure

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29045/10.05 Replaces: 01.05 1/12 Type 5WRPE 10 Size 10 Unit series 2X Maximum working pressure P 1, P 2, A, B 210 bar, T 50 bar Nominal flow rate

More information

Proportional relief valves with integral pressure transducer

Proportional relief valves with integral pressure transducer www.atos.com Table FS040-/E Proportional relief valves with integral pressure transducer digital, pilot operated, closed loop high performances, rugged design Valve main body Main poppet Mechanical pressure

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 CONTENTS: RH06...1 - electrical control... RH06...2 - hydraulic control... Page 1/17...7/17 8/17...9/17 RH06...4 - mechanical control RH06...6 - pneumatic control......

More information

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification www.atos.com Table TE137-1/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification Ex-proof solenoid Valve body

More information

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback RE 29159/07.05 1/10 Type DBEBE6X Nominal size 6 Unit series 1X Maximum working pressure P 315 bar,

More information

Proportional reducing valves with integral pressure transducer

Proportional reducing valves with integral pressure transducer www.atos.com Table FS020-2/E Proportional reducing valves with integral pressure transducer digital, direct operated, closed loop high performances, rugged design Valve body Poppet Proportional solenoid

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve. AP64E00DX00X Characteristics to VDI 90 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Spool valve Mounting screws M Tube connection Thread Port size ; 7.4 deep

More information

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated Proportional cartridge throttle valve, with inductive position transducer, pilot operated RE 29215/09.05 1/18 Type FESX Nominal size 16, 25, 32, 40, 50 Unit series 1X Maximum working pressure A, B, X 315

More information

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4 EV FT3 ES-FT5 ES/GB 4 15-07-2008 16:09 Pagina 4 5 1 HOW TO READ THE MODEL CODE FOR VALVES FT3 - ES - * FT3 - ES - (1) (C) - * - (024C) / 10 2 FUNCTIONAL SYMBOLS 1C 1N 1 2 3 4 5 6 7 1 FT3 4-way directional

More information

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min 41 330/116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-05 p max 320 bar Q max 125 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-05-04-0-05 (CETOP 4.2-4-05-320)

More information

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25 41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29037/10.05 Replaces: 01.05 1/12 Type 4WRPEH 10 Size 10 Unit series 2X Maximum working pressure P, A, B 315 bar, T 250 bar Nominal flow rate 50...100

More information

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE CONTINENTAL HYDRAULICS VER03MPG PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE VER03MPG - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED WITH OBE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299

More information

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Servo solenoid valves with positive overlap and on-board electronics (OBE) Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Servo solenoid valves with positive overlap and on-board electronics (OBE) RA 2989/1.5 1/24 Model 4WRLE

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK CONTINENTAL HYDRAULICS VED*MJ PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*MJ PILOTED

More information

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback 4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback RE 29025/01.05 1/16 Replaces: 05.04 Type 4WRPE..E.. /..W.. Size 6, 10 Unit series 2X Maximum working pressure

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

Flow sharing control block in sandwich plate design M7-25

Flow sharing control block in sandwich plate design M7-25 Flow sharing control block in sandwich plate design M7-25 RE 64297 Edition: 07.2016 Replaces: 06.2012 Size 25 Series 3X Maximum working pressure on the pump side 380 bar on the consumer side 420 bar Maximum

More information

General Specifications DRV DRV-Exm DRV-Exd

General Specifications DRV DRV-Exm DRV-Exd direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to

More information

2/2 CARTRIDGE VALVES LOGIC ELEMENTS

2/2 CARTRIDGE VALVES LOGIC ELEMENTS 2/2 LOGIC ELEMENTS AND COVERS KEL.16/2... CH. V PAGE 3 NG16 / NG2 KEL SEATS CH. V PAGE 4 KEC.16/2... CH. V PAGE KEC HYDRAULIC MOUNTING DIAGR. CH. V PAGE 6 KEC.16/2... WITH CMP CH. V PAGE 10 C.*.P.16/2...

More information

V*L Pressure control valves in line

V*L Pressure control valves in line V*P / V*L... V*P... cap. II 7 V*PE... cap. II 8 V*L... cap. II 9 - Cap. II 10 BSVMP... cap. II 11 KEC16/5... cap. II 9 C*P16/5... cap. II 9 CETOP 3/NG06 cap. II 8 Standard spools for AD3E Cap. II 10 AD3E...

More information

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE CONTINENTAL HYDRAULICS VED*MG PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*MG PILOT

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Contents Chapter 5: Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 0 10 1 Subplate Screw-in Throttle valves, manual adjustment MVI 5-3 NS 5-5 FS With free

More information

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C 2/2-Way Function / Cavity conform to ISO 7368 (DIN 24342) Publ. 7 EN 5060 A FEATURES, DESCRIPTION FEATURES x High flow cartridges give highest

More information

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006 NO. 10 01E September 1, 2010 Public Relations Group Products Publicity Section Sales Administration Department Hamamatsucho Seiwa Bdg., 4-8, Shibadaimon 1-chome, Minato-ku, Tokyo 105-0012, Japan Tel: +81-3-3432-2113

More information

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPE RE 29122 Edition: 2014-11 Size 10 Component series 3X Maximum operating pressure

More information

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Directional Control Valves, electrically operated Type WE 5 Huade América 1 Directional Control Valves, electrically operated Type WE 5 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Directional control valves, electrically operated Type WE 5 Size5 up to 25

More information