CURRENT LIMITING SUBPANEL

Size: px
Start display at page:

Download "CURRENT LIMITING SUBPANEL"

Transcription

1 Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION The Juno Trac-Master Current Limiting Subpanel is THE solution for complying with stringent energy codes like ASHRAE 90.1 and California Title 24. Typically for trac lighting, it is defined as a sub-branch circuit current limiter designed to limit available wattage to lighting circuits, to only that necessary to meet the lighting design criteria. The Trac-Master Subpanel employs supplementary current limiting circuit breakers configured specifically for the lighting design in the space. Rather than lighting loads being calculated by the greater of maximum fixture wattage ratings or an arbitrary watts per foot multiplier, the Trac-Master Subpanel enables calculations to instead be made based on the rating of the supplementary subpanel breaker. Because it limits a circuit not the lighting equipment itself, the Trac-Master subpanel provides maximum flexibility to accommodate frequent lighting design modifications and layout changes, especially typical for retail spaces. PRODUCT SPECIFICATIONS Features Designed to be installed between the branch circuit breaker and the lighting equipment Not intended to be used as a primary circuit protector Factory pre-assembled and customized No programming required. Construction Heavy-duty 16 gauge die formed steel enclosure Hinged door with key-locking latch Removable front panel with factory labeled breaker wiring data simplifies installation Ample quantity of combination ( 1 / 2, 3 / 4, 1 ) knockouts provide maximum installation flexibility for top, bottom and side conduit connections Precision 35mm DIN rail mounting secures breakers in place Includes ample ground terminals for all circuits Mini panel accommodates 1 to 12 circuits, standard panel accommodates 6 to 21 circuits and large panel accommodates 22 to 42 circuits Mini panel available in surface mount configuration only Standard and large available in surface mount or flush mount configurations. Finish Durable powder coat paint Industrial gray color standard. Supplementary Current Limiters Single pole supplementary protectors Rated for 120/277VAC operation Available in individual amperage ratings including 0.5A, 1A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 10A, 13A and 15A, selected based on actual lighting loads Protectors should be loaded to a maximum of 80% of rating to avoid nuisance tripping Wiring installs directly into protector terminal Color-coded ON/OFF indicator clearly identifies status Easily resettable in an accessible location in the event of an overcurrent situation UL 1077, CSA 22.2, IEC approved. Labels UL Listed cul Listed Approved by the California Energy Commission to meet the requirements of Title 24 Complies with ASHRAE Warranty Product is warranted against defects in material and workmanship for a period of 3 years. Product specifications subject to change without notice. ORDERING INFORMATION Supplementary Current Limiter ratings are determined by the electrical layout drawings. A submittal package will be provided by Juno for approval following receipt of order and single line drawings. Supplementary Current Limiter ratings and position are not required to be specified as part of the catalog number. Specifications assistance is available thru local Juno Lighting Group sales representatives or by contacting Juno Lighting Group Technical Services at (888) Ordering Examples: CLS10M, CLS16, CLS21F CLS Series Number of Circuits per Panel Panel Style Mounting Style CLS = Trac-Master Current 6-21 for Standard Panel Blank = Standard Panel (6-21 circuits) Blank = Surface Mount Limiting Subpanel for Large Panel or Large Panel (22-42 circuits) F = Flush Mount (Standard or Large Panel Only) 1-12 for Mini Panel M = Mini Panel (1-12 circuits) REV-10/12

2 DIMENSIONS MINI 1-12 CIRCUIT PANEL - SURFACE MOUNT 9 1/16" 12 3/4" 3 15/16"

3 DIMENSIONS STANDARD 6-21 CIRCUIT PANEL - SURFACE MOUNT STANDARD 6-21 CIRCUIT PANEL - FLUSH MOUNT 14 1/4" 15 7/16" 17 7/8" 19 1/8" 3 13/16" 3 13/16" LARGE CIRCUIT PANEL - SURFACE MOUNT 14 1/2" LARGE CIRCUIT PANEL - FLUSH MOUNT 15 7/16" 33 13/16" 35 1/8" 3 13/16" 3 13/16"

4 MOUNTING TEMPLATE MINI 1-12 CIRCUIT PANEL MOUNTING TEMPLATE 6" 3 1/8" STANDARD 6-21 CIRCUIT PANEL MOUNTING TEMPLATE LARGE CIRCUIT PANEL MOUNTING TEMPLATE 5 1/2" 5 1/2" 15" 30 7/8"

5 APPLICATION Energy codes typically calculate trac lighting loads based on linear feet of installed trac. Some codes use a multiplier as low as 30 watts/foot while others use a multiplier as high as 70 watts/foot. When using the energy efficient lighting technologies available today, the connected load is typically much less than the per-foot multipliers used by most energy codes. This penalizes lighting designs that employ trac lighting and wastes available lighting watts that could be used more effectively. Below is a typical trac lighting example. The Standard Layout consists of 100 of single circuit trac with 32 CMH trac heads, each using 39W lamps, for a total connected load of 1440W. The Revised Layout Using Short Trac Segments has the same 1440W connected load but uses sixteen short 4 trac segments (64 ), each fed separately, to help minimize the impact of the watts per foot multiplier. The scenario with the Trac-Master Current Limiting Subpanel uses the original 100 of single circuit trac, with each monitored by a 4-Amp current limiting supplementary protector that is closely matched to the actual connected load of 1440W plus a small buffer. This results in the minimum calculated watts per the energy codes. 1. Standard Layout without the Trac-Master Subpanel Revised Layout Using Short Trac Segments The Trac-Master Subpanel installs between the branch circuit breaker and the trac lighting, solving the energy code calculation discrepancy, making the wattage calculation independent of trac length. 3. Standard Layout with the Trac-Master Panel

Current Limiting Solutions. Innovative current limiting solutions for optimal trac lighting performance in an energy conscious world

Current Limiting Solutions. Innovative current limiting solutions for optimal trac lighting performance in an energy conscious world Current Limiting Solutions Innovative current limiting solutions for optimal trac lighting performance in an energy conscious world Current Limiting Solutions Table of Contents Code Compliance...2 Energy

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

133 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

133 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST 133 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed for control and instrumentation applications. They are a general-purpose enclosure intended for indoor use

More information

Juno Trac-Lites System A complete and customizable track system with an array of features

Juno Trac-Lites System A complete and customizable track system with an array of features Juno Trac-Lites System A complete and customizable track system with an array of features Juno Trac-Lites System Track sections are constructed of extruded aluminum and offer a low 1/2" profile that unobtrusively

More information

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single

More information

NT-300 Series Single Circuit Track System & Accessories

NT-300 Series Single Circuit Track System & Accessories NT-300 Series Single Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral copper conductors.

More information

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM. AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM. Product development was driven by the need to solve troubles of cabinet rack usage as well as to provide a cabinet that will efficient networking, reliability,

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information

C-Box Screw Cover with Knockouts NEMA 1. Commercial Enclosures Junction Boxes

C-Box Screw Cover with Knockouts NEMA 1. Commercial Enclosures Junction Boxes C-Box Screw Cover with Knockouts Application Designed for general purpose indoor commercial use as a junction, pull or switch box. Standards UL-50 Type 1 cul Type 1 Complies with: NEMA Type 1 IEC 60529,

More information

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems Juno Trac-Master Trac Lighting Systems Comprehensive line and low voltage track systems Juno Trac-Master System Safe and simple installation is what you can expect from Juno one-circuit and two-circuit

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

ZoneZ Lite Quick Start Guide

ZoneZ Lite Quick Start Guide Table Of Contents Preparation......2 ZoneZ Lite Overview....3 ZoneZ Lite Contact Closure Wiring......4 ZoneZ Lite Contact Closure Three-Way Wiring....5 ZoneZ Lite Contact Closure All On/Off Wiring.....6

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Coleman Air ITS-240 Inverter Transfer Switch

Coleman Air ITS-240 Inverter Transfer Switch Coleman Air ITS-240 Inverter Transfer Switch For: 240 Volts A/C, Split phase and 120 Volts A/C inverters. 12/24/48v Systems The Coleman ITS-240 Inverter Transfer Switch Inverter 240 VAC split phase or

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM. AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM. Product development was driven by the need to solve troubles of cabinet rack usage as well as to provide a cabinet that will efficient networking, reliability,

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

Installation Instructions for Eaton Surge Protective

Installation Instructions for Eaton Surge Protective Contents Description Page PH Model Introduction.... 2 Safety Precautions.... 2 Operation.... 2 Preparation... 2 Installation Procedures... 3 Enclosure Mounting (New Applications - Eaton PH and PV Models)....

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Weather Protective Devices

Weather Protective Devices Weather Protective Devices N Industrial Specification Grade Receptacle Covers N-1, N-2 Weather Protective Devices N-3 Power-Lock Receptacles and Flanged Inlets with Weather Protective Lift Lids N-4 50

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903) ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX 75568 (903) 897-0737 fax (903) 897-0740 Pedestal Starter-Disconnect Pedestal Starter Controller Installation Instructions

More information

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120 USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120 OVERVIEW The Autopilot Fuel SX12 Twelve Light X-Plug 120/240V Light Controller (APTX0120) represents the latest in large scale

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Series A DC Link Chokes

Series A DC Link Chokes Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

ICN2S40N35I Ele Ballast (2) F40T V

ICN2S40N35I Ele Ballast (2) F40T V 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN2S40N35I Ele Ballast (2) F40T12 120-277V Philips Advance Catalog Number Manufacturer Description Weight per unit Product

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS Overview Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID ballasts bring significant performance improvements to HID lighting systems: Higher efficiency Greater

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

MnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18

MnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18 1. LISTING REQUIREMENTS MnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18 1.1. The luminaire shall be listed by a National Recognized Testing

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012

MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1. LISTING REQUIREMENTS MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL) as defined by the U.S.

More information

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Fused Coordination Panelboard

Fused Coordination Panelboard Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and

More information

GLX. Series. 1kW to 16kW Central System

GLX. Series. 1kW to 16kW Central System GLX Series 1kW to 16kW Central System GLX Series Sine Wave RATINGS TABLE Size Input Current @120V Output Current @120V Input Current @277 Output Current @277 Output Watts Battery (DC) Voltage 1kW 16 8

More information

UL AND CODE COMPLIANCE

UL AND CODE COMPLIANCE BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

INSTRUCTION MANUAL L WIND CONE

INSTRUCTION MANUAL L WIND CONE Cooper Industries DOCUMENT September 29, 2009 Revision B Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 Title: INSTRUCTION

More information

RELB2S40N35I (2)F40T12 120V Ele BLST

RELB2S40N35I (2)F40T12 120V Ele BLST 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RELB2S40N35I (2)F40T12 120V Ele BLST Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables Technical Brief Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables Contents Overview... 1 Voltage Rise for M215s with the 240 VAC Engage Cable... 2 Voltage Rise for M215s with

More information

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount 150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower - 5-12' -Surface Mount Part #: EPL-APM-150LED-RT Page: 1 Made in the USA The EPL-APM-150LED-RT Telescoping Pole Mounted Explosion

More information

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert

More information

CC/CCS21 21" Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf

CC/CCS21 21 Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf Catalog number: Approvals: / / / / Mtg. Fixture Electrical Module Finish Options See page 4 See page 2 See page 3 Select pole from Kim Arms and Poles Selection Guide. If pole is provided by others indicate

More information

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym. HVAC Farm Duty Fractional Horsepower DC Speed Controls for PMDC DC & Controls 1/15 thru 1/4 115 VAC Single Phase 50/60 Hz. Applications: Conveyors, machine tools and other applications requiring adjustable

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service

More information

SURFACE - LINEAR - FLUSH

SURFACE - LINEAR - FLUSH Project Type Notes PERFORMANCE PER LINEAR FOOT AT 4K SO Spotless Lens Mini Driver ML Mini Driver B Blank SO lens Option only Micro louver Option only NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY 2 lm/ft

More information

Coleman Air ITS-240 Inverter Transfer Switch

Coleman Air ITS-240 Inverter Transfer Switch Coleman Air ITS-240 Inverter Transfer Switch For: 240 Volts A/C, Split phase and 120 Volts A/C inverters. 12/24/48v Systems The Coleman ITS-240 Inverter Transfer Switch Typical A/C Wiring. This diagram

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B 150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B Part #: HBLP-REMG-1MLED-B-PND Page: 1 Made in Texas The Larson Electronics HBLP-REMG-1MLED-B-PND LED

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description NEMA 1 Enclosed DC Controls for PMDC and Shunt Wound DC & Controls 1/100 thru 2 Hp 115/230 VAC Single Phase 50/60 Hz. Applications: General purpose industrial use with permanent magnet or shunt wound DC

More information

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning 156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning Part #: EPL-360-3XLP24-LED-V2-100 Page: 1 Made in Texas The EPL-360-3XLP24-LED-V2-100 Portable Explosion

More information

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.

More information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh Part #: HALP-48-2L-LED Page: 1 Made in the USA The Larson Electronics HALP-48-2L-LED Hazardous Area

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp 45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp Part #: EPL-48-2L-45D Made in the USA The Larson Electronics EPL-48-2L-45D Explosion Proof Fluorescent

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

Lighting Systems Argus-7

Lighting Systems Argus-7 Page 1 of 5 1 1. (3.5cm) 1.7 (4.3cm) 4 5 Rectilinear 3 1.81 (4.6cm) Extruded Linear Louver.5 (.64cm) 5. (1.7cm) 9. (.86cm) 1 1. (3.5cm) 1.7 (4.3cm) 4 5 Tapered 3 1.81 (4.6cm).75 (.7cm) Feature Specifications

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel Part #: HAL-48-2L-LED-BMSW-G2 Page: 1 Made in the USA The Larson Electronics HAL-48-2L-LED-BMSW-G2 Hazardous

More information

PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE

PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection for standard off-the-shelf

More information

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses... Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

EBMC Combination Line Starters and Enclosures

EBMC Combination Line Starters and Enclosures EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Quik-Spec Coordination Panelboard

Quik-Spec Coordination Panelboard Read and retain for future reference Quik-Spec Coordination Panelboard Instruction Leaflet 3A1071 RevD Section TABLE OF CONTENTS Page Danger and warnings for installation of the equipment.............3-4

More information

Receptacles & Wall Boxes with Integral Circuit Protection

Receptacles & Wall Boxes with Integral Circuit Protection product description New Product Announcement Issue date: 25 January 2012 Receptacles & Wall Boxes with Integral Circuit Protection Meltric s receptacle/wall box combinations with integral circuit protection

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

MNDC-X2 INSTRUCTIONS

MNDC-X2 INSTRUCTIONS MNDC-X2 INSTRUCTIONS Models: MNDC125-X2, MNDC175-X2, MNDC250-X2 The MNDC125-X2 Based on our Narrow E-Panel chassis and MNDC175-X2 and MNDC250-X2 based on our wide E-Panel chassis with a blank door the

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Two Seas Metalworks Shell Lane fax Rev

Two Seas Metalworks Shell Lane fax Rev This catalog provides product information and pricing for our complete line of Battery Enclosures and Battery Racks designed specifically for the PV industry to hold different sized batteries from all

More information

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800.

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800. Standby 30 kw, 38 kva Prime 27 kw, 35 kva 60 Hz Image shown may not reflect actual configuration Specifications Frequency Voltage Standby kw (kva) Prime kw (kva) Speed rpm 60 Hz 480/277V 30 (38) 27 (35)

More information

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation! Demand Switch NEFA20 Plus Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Protective Covers DIN Mounting Rail NEFA20 Plus Mounting Rail Spacer Warning

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

East Central College

East Central College SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Wall switches. b. Receptacles c. Device plates and decorative box covers. 1.2 RELATED

More information

Options. Pole and Arm. Suitable for wet locations

Options. Pole and Arm. Suitable for wet locations Catalog number: / / / Mtg. Fixture Electrical Module Finish See page 2 See page 3 Options Pole and Arm Select pole from Kim Arms and Poles Selection Guide. If pole is provided by others indicate O.D. for

More information

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting Linear Fluorescent Highbays A comprehensive selection of high output commercial/industrial fluorescent lighting Linear Fluorescent Highbay Lighting T-Series Full Body, Specification Grade Fluorescent Highbay

More information

Kaedra Weatherproof DIN Type Enclosures

Kaedra Weatherproof DIN Type Enclosures Multi 9 System Catalog Section 6 Additional System Devices Kaedra Weatherproof DIN Type Enclosures Applications Expandable enclosures for service, industrial, or equipment applications Protects against

More information

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications PRODUCT FEATURES: 6" sealed, recessed downlight with regressed or flush lens trim Conducted emissions controlled as per MIL-STD-461F Delivered lumens: 794-5,543 lm 1% Dimming via 0-10V, DALI or EcoSystem

More information

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps 3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,

More information

JOB NAME MODEL NO. LAMP OUTPUT VOLTAGE

JOB NAME MODEL NO. LAMP OUTPUT VOLTAGE Specification Sheet Components LED Control CPS 10875 JOB NAME MODEL NO. LAMP Determine the maximum fixture wattage per circuit by adding the wattage of each fixture together and choose an LED power supply

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and s NEMA 4X UL 1598 Wet & s CUL IP65 NSF Enclosure N M F 2 339 NMF2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information