FLEXIBLE HEATED HOSES

Size: px
Start display at page:

Download "FLEXIBLE HEATED HOSES"

Transcription

1 FLEXIBLE HEATED HOSES TYPE ELH UP TO 350 C AND EX FOR HAZARDOUS ZONES The ideal solution that eltrace offers to the transportation of liquids and gases. Long life, high resistance to temperature uniform distribution of heat and the use of high quality materials guarantee high effectiveness and optimum use. Protection against freezing Protection against condensate forming. Maintain liquid and gas temperatures Maintain temperature of viscous products. Transport of liquids or gases between fixed and mobile installations (robot equipment) Hot bonding systems Projection of expanded polyurethane Wax transformation Analytical gas measurements Asphalt transformation installations Transformation of agro-food products Transfer of road tankers TAILOR-MODE CONSTRUCTION: Models are according to standard panel units and technical data sheets or to special specifications. Hydraulic connectors: Connector model: bichromate steel, stainless steel, brass. see table of accessories. Operating temperature range: from 5 to 350 C Pressure load limit: Flexible line length: Temperature sensor: External protection casing: Connecting cable: Connection cables: Connection plug: Temperature regulator: o D (without pressure) m D (medium pressure) h D (high pressure) variable, from 30 m for two heating circuits. PT 100-2,3 or 4 wires, thermocouples. stainless steel braid, nylon, galvanized steel, ribbed metal flexible with PVC casing 1 m standard, other lengths on order heating circuit, control circuit and temperature sensor combined or separate. round multi-pole 2200 VA connector, as an or any other design required by customer. see regulation technical leaflet.

2 FLEXIBLES CHAUFFANTS CONSTRUCTION: PTFE internal flexible line for the transport of liquids and gases. Armature consisting of one or two stainless steel braids guaranteeing pressure resistance. Hydraulic connectors mounted at ends of flexible line manufactured of very high quality material. Heat element wound around PTFE tube to ensure heating and temperature maintenance. The computer calculates the length and resistance. Interconnecting cables between the two ends of the flexible line for information (temperature) and power transfer. Thermal insulation adapted to operating temperatures and conditions. External braid for mechanical protection. Special assembly to prevent subsequent removal. Flexible line ends provided with silicon rubber protection fittings to ensure technically clean termination. Temperature sensor ( PT100, thermocouple, ) connected to electronic regulator maintaining transported product temperature, even for outside temperature variations. The flexible heating line meets the current standards. SUITABLE FOR HAZARDOUS AREAS Heating flexible lines and conduits are necessary in areas where there is an explosion hazard, coming under individual site inspection, or at eltrace production locations. The composition of the heated flexible line, resisting explosion, differs from the standard heating flexible line through the use of components approved by the European laboratories, such as heated cables, self-regulated heating tape, junction boxes, regulators, etc. ELTRACE can equip and supply all standard models, special flexible lines, stainless steel or copper tubes with a heating and control system approved for use in hazardous zones. Heating, in general, is by a heating cable conforming to European standards, heating tape with PTFE covered elements or self-regulating heated tape. The corresponding control certificates are included with the equipment. Because this equipment is manufactured to order only, our "project managers" are available to our customers for any information or special studies. FOR THE APPLICATION OF EXPANDED POLYURETHANE Double flexible heating line for two-part flexible projection with two PTFE tubes, one resisting pressure and one for compressed air. Nominal diameter: 2 x 6mm to 2 x 13mm. Maximum operation temperature: 80 C FOR THE ANALYSIS TECHNIQUE PTFE heating flexible line bundles Several PTFE tubes can be provided with heating, with the assembly isolated and covered with a protection cover. For low temperatures, maintenance by self-regulated heating tapes. Version for use in hazardous zones: on request.

3 FLEXIBLES CHAUFFANTS Basis: ELH/md - ELH/hd - ELH/a - ELH/sb Accessories : /i - /T - /it - /w - /Ex (explosion) CHARACTERISTICS AND VARIANTS ELH/md : Medium pressure flexible line with connectors at both ends /Ex Flexible line suitable for dangerous areas. ELH/hd : High pressure flexible line with connectors at both ends Temperature range: 100 C, 200 C, 250 C /Ex Flexible line suitable for dangerous areas. ELH/a: ELH/ad : ELH/ak : ELH/ae : ELH/sb : Analysis line Pressure-free service PTFE fixed internal flexible line Analysis line pressurized service RSL equipment at both ends analysis line with fixed copper internal pipe Analysis line with fixed stainless steel inside tube, 350 C /I Interchangeable internal PTFE flexible line /it /Ex flexible line suitable for dangerous areas. Interchangeable internal PTFE flexible line and sheath resisting pressure of foot Analysis line pressure-free service fixed PTFE tube Heating by self-regulating heating tape Manufacturing: factory Temperature ranges: antifreeze protection, 120 C Inside protection braid: "black" nylon ELH/sbA : Analysis line pressure-free service - fixed PTFE tube Heating by self-regulating heating tape Manufacture: on reel, cut to necessary length at expense of client Temperature ranges: antifreeze protection, 120 C Inside protection braid: "black" nylon /i tube PTFE interchangeable /it Interchangeable PTFE tube and cover resisting pressure of foot /Ex flexible line suitable for dangerous areas.

4

5 FLEXIBLE HEATING JACKETS Flexible Heating Jackets FULL RANGE OF FLEXIBLE HEATING JACKETS ADAPTED TO YOUR APPLICATIONS ELTRACE manufactures a range of flexible heating jackets particularly suited for the following applications: We have the technology to design jackets suitable for any shape of support. These are particularly flexible jackets and particularly easy to install in difficult to reach areas. The product is flexible, allowing excellent contact with the surface to be heated, meaning that the temperature is uniform and avoiding any hot points from forming. Taps and fittings in general Automatic valves Pneumatic or electric transmitters Flowmeters Meters and rotameters Ice levels Local indicators and pressure gauges Distribution "Clarinets" Filters Various tanks Pipe sections, flanges, couplings, etc. Protection of equipment exposed to flame or sparks TECHNICAL CHARACTERISTICS: Maximum power: 4800 Watts/m² Power supply voltage from 24 to 400 volts Design of silicon glass fabric or aluminum-coated glass fabric Amagnetic construction if necessary Many circuits per heating zone Backup heating circuits Total insulation by mineral or ceramic fiber Attaching eyelets for hooks built in to facilitate assembly JACKET DESIGN The outer envelope of the mattress consists of suitable fabric depending on the environment and the temperature requirements. The inside envelope is chosen according to the temperature of the product being conveyed, allowing for aggressions and dangers caused by malfunctioning. The heating wire is attached to the inside envelope on the mattress side. The insulating material is enclosed between two sealed envelopes, the various parts of which are stitched tightly together by fire-proof thread. The mattress formed in this way, previously formed of the equipment to be heated and/or insulated, is held in place by self-attaching strips to facilitate repeated disassembly and assembly. Each mattress can be equipped with a temperature sensor.

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

eltherm HEATED HOSES HEATED LINES HEATED TUBING BUNDLES AND ACCESSORIES

eltherm HEATED HOSES HEATED LINES HEATED TUBING BUNDLES AND ACCESSORIES HEATED HOSES HEATED LINES HEATED TUBIN BUNDLES AND ACCESSORIES Important information standard heated hoses are available for temperatures up to 250 C and a pressure range up to 500 bar (depends on the

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 11 Applications For direct installation into the process Machine building

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

Heated Hoses... 3 Applications Ex Heated Hoses for Analysis Technique, Type ELH/a... 5 Technical Details for Analytic Hose...

Heated Hoses... 3 Applications Ex Heated Hoses for Analysis Technique, Type ELH/a... 5 Technical Details for Analytic Hose... Heated Hoses Table of Content Heated Hoses... 3 Applications... 4 Ex Heated Hoses for Analysis Technique, Type ELH/a... 5 Technical Details for Analytic Hose... 6 Ex Heated Hoses for Analytic, Self-regulating

More information

Heated hoses Analytic hoses. innovations in heat tracing

Heated hoses Analytic hoses. innovations in heat tracing Heated hoses Analytic hoses innovations in heat tracing eltherm GmbH eltherm GmbH is an international operating company specializing in the field of electrical heat tracing systems. With more than 40 years

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the

More information

Article on Sheath materials, Thermowells, Fittings, and Terminations

Article on Sheath materials, Thermowells, Fittings, and Terminations Article on Sheath materials, Thermowells, Fittings, and Terminations 1. INTRODUCTION Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or

More information

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751 ata Sheet 902210 Page 1/12 Mineral-Insulated RT Temperature Probe According to IN EN 60751 For temperatures from -50 (-200) to +600 C Flexible sheath cable with vibration-resistant measuring insert As

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 further approvals see page 11 Applications For direct installation into the process Machine building

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

LIGHTNING EQUIPOTENTIAL BONDING ISOLATING SPARK GAPS. EXFS L / EXFS KU for explosive Areas

LIGHTNING EQUIPOTENTIAL BONDING ISOLATING SPARK GAPS. EXFS L / EXFS KU for explosive Areas EXFS L / for explosive Areas For indirect connection/earthing of functionally separate system parts at lightning strikes Unit for lightning equipotential bonding according to IEC 61024-1 for hazardous

More information

Heated hoses Analytic hoses. innovations in heat tracing

Heated hoses Analytic hoses. innovations in heat tracing Heated hoses Analytic hoses innovations in heat tracing eltherm GmbH eltherm GmbH is an international operating company specializing in the field of electrical heat tracing systems. With more than 40 years

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 for further approvals see page 11 Applications For direct installation into the process Machine building Motors

More information

Armoured / Un-armoured Cable Gland

Armoured / Un-armoured Cable Gland Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

N Series Ex d Stainless Steel

N Series Ex d Stainless Steel MUR Mounted, Pilot Operated Spool Type Solenoid Valve Flame Proof Stainless Steel Enclosure, COMO Interface Series Stainless Steel MUR Mounted, Pilot Operated Spool Type Solenoid Valve IIC T4/T6 Flame

More information

Special seals Index. General information. Product information Gaskets with inner eyelet Series 1003/ Gaskets and seals HC-001 page 984

Special seals Index. General information. Product information Gaskets with inner eyelet Series 1003/ Gaskets and seals HC-001 page 984 Index General information Product information Gaskets with inner eyelet Series 1003/1013 985 Mica Hi-Temp Mica Hi-Temp 986 PTFE envelope gaskets Series 1027 987 Inertex tape Index 988 Inertex UHF Joint

More information

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017 ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,

More information

WAFER STYLE KNIFE GATE VALVE

WAFER STYLE KNIFE GATE VALVE 11 WAFER STYLE KNIFE GATE VALVE The model knife gate is an uni-directional wafer valve designed for general industrial service applications. The design of the body and seat assures non-clogging shut off

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

Product Overview. Application

Product Overview. Application Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated

More information

SEMI, manufacturer of superior quality electrical flexible conduit and fittings systems. Over Braided Liquid Tight Conduit ( YF-705 )

SEMI, manufacturer of superior quality electrical flexible conduit and fittings systems. Over Braided Liquid Tight Conduit ( YF-705 ) Over Braided Liquid Tight Conduit ( YF-705 ) Trade Size I.D. (mm) O.D. (mm) Min Bending MIN. MAX. MIN. MAX. Meters/Coil YF-70503 3/8" 12.3 12.8 18.5 19.0 75 50 YF-70504 1/2" 15.7 16.3 21.8 22.3 95 50 YF-70506

More information

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,

More information

Hot runner thermocouple Model TC46

Hot runner thermocouple Model TC46 Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

HOPPER SHAPE KNIFE GATE VALVE

HOPPER SHAPE KNIFE GATE VALVE HOPPER SHAPE KNIFE GATE VALVE The model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). The special design of the

More information

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement TE 65.01 Thermocouples Measuring Insert Electronic Temperature Measurement rigid Model TC 001 flexible Model TC 002 Services intended Exchangeable measuring insert for all industrial and laboratory applications.

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

NEC 2011 Code Changes

NEC 2011 Code Changes NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 Applications For direct installation into the process Machine building Motors Bearings Pipelines and vessels Special

More information

WAFER STYLE KNIFE GATE VALVE

WAFER STYLE KNIFE GATE VALVE WAFER STYLE KNIFE GATE VALVE The EX(SER.10) model knife gate is an uni-directional wafer valve designed for general industrial service applications. The design of the body and seat assures non-clogging

More information

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES ABOUT LABFACILITY Formed in 1971, Labfacility specialises in the field of Temperature and Process Measurement. We are the largest UK manufacturer of both

More information

Capri ADE 6F - for Armoured Cable

Capri ADE 6F - for Armoured Cable Capri ADE 6F - for Armoured Cable Technical Specification Suitable for the following cable types Steel wire armoured cable (SWA) Steel wire braided cable (SWB) Steel tape armoured cable (STA) Braided marine

More information

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)... Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG

More information

Hot Runner Thermocouples Model TC46

Hot Runner Thermocouples Model TC46 Electrical Temperature Measurement Hot Runner Thermocouples Model TC46 WIKA Data Sheet TE 65.46 Applications Plastics and rubber industry Hot Runner bushings, drops and nozzles Hot Runner manifolds Moulds

More information

Natural Gas Truckee Tahoe Airport Road Truckee CA

Natural Gas Truckee Tahoe Airport Road Truckee CA Natural Gas Markets: Midstream (Transmission to processing) Chemical Processing Power Generation Refineries Utilities Applications: Transportation (Natural Gas Vehicles) Moisture Analysis Fertilizer Production

More information

Centrifugal pumps. made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies

Centrifugal pumps.  made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies Vertical and horizontal centrifugal pumps www.jesspumpen.com Centrifugal pumps made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies Vertical centrifugal pumps of the

More information

Probe Type Accuracy Handle Shaft Cable Plug Model Surface Probes Max. temp. at tip 7 sec. 220 C 428 F Response time

Probe Type Accuracy Handle Shaft Cable Plug Model Surface Probes Max. temp. at tip 7 sec. 220 C 428 F Response time Probe Type Accuracy Handle Shaft Cable Plug Technical data probes type K : K type thermocouple : Class I Premium grade : ABS, 110 mm long, 90 C max. : Stainless steel : 1000 mm standard. Coiled polyurethan

More information

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product Series TCM Multipoint Thermocouple Assemblies Multipoint Thermocouples are used in a broad range of processes and installations to monitor the temperature in multiple positions or elevations. These sensors

More information

THROUGH CONDUIT KNIFE GATE VALVE. OBX 09/11 2nd EDITION Revision 1 Reserves the right to change specifications without notice

THROUGH CONDUIT KNIFE GATE VALVE. OBX 09/11 2nd EDITION Revision 1 Reserves the right to change specifications without notice THROUGH CONDUIT KNIFE GATE VALVE The model knife gate is a bi-directional wafer valve designed for media with high consistency. The double seat design assures a non-clogging shut off on either normal or

More information

Valve Solutions for the Bulk Material Industry

Valve Solutions for the Bulk Material Industry Valve Solutions for the Bulk Material Industry SUCCESS STORY Plant name & location: Tronox, llc. Hamilton, Ms Application: Ore Silo Inlet Media: Titanium Rutile Ore Tronox, llc., formerly Kerr McGee Chemical

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

September 2012 / M&H C502 / Model 129

September 2012 / M&H C502 / Model 129 GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line

More information

HOPPER SHAPE KNIFE GATE VALVE

HOPPER SHAPE KNIFE GATE VALVE HOPPER SHAPE KNIFE GATE VALVE The C model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). makes it ideal for use

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx THERMOCOUPLE CABLE Customization Customized colour option and printing of the outer sheath on request Compensating & Extension 1601 Application: Compensating or Extension Cables are used in temperature

More information

For the plastics machinery industry Manifold thermocouple Model TC47-MT

For the plastics machinery industry Manifold thermocouple Model TC47-MT Electrical temperature measurement For the plastics machinery industry Manifold Model TC47-MT WIKA data sheet TE 67.21 Applications Plastics and rubber industry Hot runner manifolds for injection mould

More information

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel ADE 4F 4 F U N C T I O N S : D O U B L E > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass and stainless steel > Optional : aluminium and bronze raw material

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Short Form Catalogue AJ Thermosensors

Short Form Catalogue AJ Thermosensors Thermocouples Short Form Catalogue AJ Thermosensors Resistance thermometers Head mounted Probe style Application specific Accessories See the individual datasheets for more detailed information on each

More information

The safety you rely on.

The safety you rely on. Cable Glands Global Solutions Catalogue The safety you rely on. Cable Glands & Accessories Global Solutions Introducing Crouse-Hinds by Eaton The leader in electrical products for hazardous, industrial

More information

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Pneumatic Retractable Fittings Chem Energy Pharm Food Water Ceramat Sensor Lock-Gate Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Unique lock-gate principle The

More information

Technical changes kept in reserve THROUGH CONDUIT KNIFE GATE VALVE

Technical changes kept in reserve THROUGH CONDUIT KNIFE GATE VALVE Technical changes kept in reserve THROUGH CONDUIT KNIFE GATE VALVE The B model knife gate is a bi-directional wafer valve designed for media with high consistency. The double seat design assures a non-clogging

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

GENERAL FEATURES / SPEC M&H AWWA C502 FIRE HYDRANTS Style 929 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approval Type: Compression type, opening against line pressure.

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Mineral Insulated Resistance Thermometers (RTD)

Mineral Insulated Resistance Thermometers (RTD) Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types

More information

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating

More information

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the

More information

Industrial Pt100 RTD's

Industrial Pt100 RTD's CA 2001 Resistance Welded process connection measuring insert. Can be Type CA 2001 CA 2003 Resistance Welded process connection 1/2"BSP Head extension 50mm standard. Aluminium Replaceable 6mm Din insert.

More information

JUNCTION BOXES AND SUNSHADES

JUNCTION BOXES AND SUNSHADES JUNCTION BOXES AND SUNSHADES Description The SITES S.r.l. enclosure system winterizes process instruments and protects them from corrosion and mechanical abuse. A full range of enclosures sizes are available

More information

Transair: Advanced Pipe Systems Pocket Installation Guide [1/2"] [1"] [1 1/2"] [2"] [2 1/2"] [3"] [4"] [6"]

Transair: Advanced Pipe Systems Pocket Installation Guide [1/2] [1] [1 1/2] [2] [2 1/2] [3] [4] [6] Transair: Advanced Pipe Systems Pocket Installation Guide [1/2"] [1"] [1 1/2"] [2"] [2 1/2"] [3"] [4"] [6"] Certifications and guarantees Offering a full range of diameters to fit your design needs. Transair

More information

COMPLETE LISTING OF OPTIONS. Toggles, Lights

COMPLETE LISTING OF OPTIONS. Toggles, Lights COMPLETE LISTING OF Toggles, Lights A001 A002 Local Auto/Manual Toggle Switch - NEMA 4. Switch for Auto (i.e. 4-20 ma from control room), or Manual (local control at actuator). Switch is maintain type.

More information

SERGE BARIL HA-S HAZARDOUS AREA SEAL KIT

SERGE BARIL HA-S HAZARDOUS AREA SEAL KIT INSTRUCTIONS DESCRIPTION The HA-S Hazardous Area Seal Kit provides the cable termination and explosion proof seal parts needed to make all in-line electrical splice connections associated with Serge Baril

More information

D Series Ex d Stainless Steel

D Series Ex d Stainless Steel 2 Way irect Acting Solenoid Valve IIC T4/T6 Series Stainless Steel 2 and 3 Way irect Acting Solenoid Valve IIC T4/T6 2SK-CM [ FEATURES ] Integral terminal box with coil housing. Valve do not require minimum

More information

L15 HEAVY DUTY KNIFE GATE VALVE STANDARD PARTS LIST

L15 HEAVY DUTY KNIFE GATE VALVE STANDARD PARTS LIST L15 HEAVY DUTY KNIFE GATE VALVE The L15 model knife gate is a uni-directional lug type valve designed according to MSS-SP-81 and TAPPI TIS 405-8 for industrial service applications. The design of the body

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process

More information

Design specifications

Design specifications Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor

More information

Products: Composite Hose Metall Hose Bellows, Compensators Swivel Joints Composite Hose. Metall Hose, Bellows and Compensators

Products: Composite Hose Metall Hose Bellows, Compensators Swivel Joints Composite Hose. Metall Hose, Bellows and Compensators Composite Hose Metall Hose Bellows, Compensators Swivel Joints Composite Hose Very flexible and easy to handle hoses for trucks, ships, railroad cars and industrial applications. Available in various designs

More information

S.P. Engineers. Spiget AN ISO 9001 : 2008 CERTIFIED GASKET MFG. COMPANY

S.P. Engineers. Spiget AN ISO 9001 : 2008 CERTIFIED GASKET MFG. COMPANY Spiget S.P. Engineers AN ISO 9001 : 2008 CERTIFIED GASKET MFG. COMPANY Manufacturer of Quality Industrial Gaskets, Spiral Wound/Low Stress Gasket, Corrugated, Jacketed - Double Jacketed. Oval-Octagonal

More information

Introduction to Heat Trace Cable Systems

Introduction to Heat Trace Cable Systems Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).

More information

HEAVY DUTY KNIFE GATE VALVE

HEAVY DUTY KNIFE GATE VALVE HEAVY DUTY KNIFE GATE VALVE The model knife gate is an uni-directional lug type valve designed according to MSS-SP-81 and TAPPI TIS 405-8 for industrial service applications. The design of the body and

More information

THERMOMETERS FOR TRANSFORMERS

THERMOMETERS FOR TRANSFORMERS THERMOMETERS FOR TRANSFORMERS GENERAL DESCRIPTION This instrument measures the insulating oil in the transformer. They are studied for withstanding to the most adverse process conditions due to the aggressiveness

More information

WAFER STYLE KNIFE GATE VALVE

WAFER STYLE KNIFE GATE VALVE WAFER STYLE KNIFE GATE VALVE The model knife gate is an uni-directional wafer valve designed for general industrial service applications. The design of the body and seat assures non-clogging shut off on

More information

UNIDIRECTIONAL Round Guillotine Damper

UNIDIRECTIONAL Round Guillotine Damper 28/02/2012 UNIDIRECTIONAL Round Guillotine Damper Gas valve, with round damper design. Unidirectional guillotine damper. Various seat and packing materials available. Face to face distance in accordance

More information

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles Terminator ZP/ Kit Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Listed Cable System 137M Terminator ZP/ The following installation procedures are suggested guidelines for the installation

More information

Technical changes kept in reserve WAFER STYLE KNIFE GATE VALVE. DN 50 to DN 250: 10 kg/cm² DN 300 to DN 400: 6 kg/cm²

Technical changes kept in reserve WAFER STYLE KNIFE GATE VALVE. DN 50 to DN 250: 10 kg/cm² DN 300 to DN 400: 6 kg/cm² WAFER STYLE KNIFE GATE VALVE The A model knife gate is an uni-directional wafer valve designed for general industrial service applications. The design of the body and seat assures non-clogging shut off

More information

Air Hoists. Lifting Equipment Ltd

Air Hoists. Lifting Equipment Ltd Air Hoists Lifting Equipment Ltd 250Kg & 500Kg Airhoist Light weight (Aluminium housing) pneumatic hoists suitable for application where duty is onerous. The component design improves handling whilst maintaining

More information

Owner s Manual. Type AGS. Aquatape Gauging System

Owner s Manual. Type AGS. Aquatape Gauging System Owner s Manual Type AGS Aquatape Gauging System M267 Rev G October 13, 2009 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 OWNER S MANUAL AQUATAPE GAUGING

More information

Electronic Monitoring Systems

Electronic Monitoring Systems JJ Electronic digital thermometer JJ Multi-channel temperature indicator JJ Temperature sensors JJ KombiTemp Electronic Monitoring Systems and Temperature Sensors DS_Electronic_monitoring_systems_and_temperature_sensors

More information

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing

More information

Tips & Technology For Bosch business partners

Tips & Technology For Bosch business partners Tips & Technology For Bosch business partners Current topics for successful workshops No. 73/2013 Gasoline injection Ignition cables technical information In gasoline engines, the high voltage required

More information

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration MI Heating Cable HDPE jacketed, copper sheathed MI cable For surface snow melting in concrete, asphalt, and pavers Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection MI

More information

Sanitary Pumps Type F 560 S Version with bearing flange

Sanitary Pumps Type F 560 S Version with bearing flange Sanitary Pumps Type F 560 S Version with bearing flange Recommended for transferring Thin to highly viscous, even pasty, still free flowing substances. Typical applications A pump designed to meet the

More information

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction SPECIFICATIONS 6 to 480 kw and higher CIRCULATION HEATERS CH & CHP SERIES Flanged construction 208 volt through 575 volt, 3 phase 5 to 40 watts/in 2 and higher NEMA 4/12 Terminal housing DESCRIPTION Type

More information

SIMOTICS FD looks different, offers more

SIMOTICS FD looks different, offers more SIMOTICS FD looks different, offers more The new definition of the asynchronous motor siemens.com/simotics-fd siemens.com Power, flexibility and efficiency redefined A motor is not always a motor. The

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Pressure Sensors. for liquid and gaseous media

Pressure Sensors. for liquid and gaseous media 1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Without thermowell Model TR10-H Temperature Resistance thermometer Without thermowell Model TR10-H WIKA data sheet TE 60.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 Electrical temperature measurement Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 WIKA data sheet TE 60.06 for further approvals see page 6 Applications Machine building,

More information

series S01 (usually CLOSED)

series S01 (usually CLOSED) BIMETALLIC THERMAL PROTECTORS series S01 (usually CLOSED) voltage: 250 V AC 50/60 Hz n interventions: 2,5 A. (10000 cicli ) 6,3 A. (3000 cicli ) Homologations: UL/CSA/VDE/BEAB/SEMKO opening C ± 5% Cable

More information