Installation Instructions
|
|
- Roderick Payne
- 5 years ago
- Views:
Transcription
1 Installation Instructions FLEX I/O Terminal ase Units 7-T, -T, -TK, -TS, -T, -TS, -TG, -TGK, -TGS, -TT, -TTS, -TN, -TNK, -TNF, -TNFK, -TKD (Modules with a K in the last position of the catalog number are conformally coated to meet noxious gas requirements of IS/NSI-7.00 lass G Environment.) Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the pplication, Installation and Maintenance of Solid State ontrols (Publication SGI-. available from your local Rockwell utomation sales office or online at describes some important differences between solid state equipment and hard-wired electromechanical devices. ecause of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell utomation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. ecause of the many variables and requirements associated with any particular installation, Rockwell utomation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell utomation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell utomation, Inc. is prohibited. Throughout this manual we use notes to make you aware of safety considerations. WRNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. WRNING WRNING When you insert or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. e sure that power is removed or the area is nonhazardous before proceeding. If you connect or disconnect wiring while the field-side power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. e sure that power is removed or the area is nonhazardous before proceeding. FLEX I/O systems are grounded through the DIN rail to chassis ground. Use zinc plated yellow-chromate steel DIN rail to assure proper grounding. The use of other DIN rail materials (for example, aluminum or plastic) that can corrode, oxidize, or are poor conductors, can result in improper or intermittent grounding. Secure DIN rail to mounting surface approximately every 00 mm (7. in.) and use end-anchors appropriately. Prevent Electrostatic Discharge This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. Use a static-safe workstation, if available. Store the equipment in appropriate static-safe packaging when not in use. IMPORTNT Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. ttentions help you identify a hazard, avoid a hazard, or recognize the consequence Do not remove or replace a Terminal ase unit while power is applied. Interruption of the backplane can result in unintentional operation or machine motion. Environment and Enclosure Do not wire more than conductors on any single terminal. This equipment is intended for use in a Pollution Degree industrial environment, in overvoltage ategory II applications (as defined in IE 0-), at altitudes up to 000 m ( ft) without derating. This equipment is considered Group, lass industrial equipment according to IE/ISPR. Without appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances. This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of V, V, V, V0 (or equivalent) if non-metallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. In addition to this publication, see: Industrial utomation Wiring and ing Guidelines, for additional installation requirements, llen-radley publication NEM Standards 0 and IE 0, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Personnel responsible for the application of safety-related Programmable Electronic Systems (PES) shall be aware of the safety requirements in the application of the system and shall be trained in using the system. Publication 7-IN0D-EN-P - pril 00
2 FLEX I/O Terminal ase Units North merican Hazardous Location pproval The following terminal bases are Hazardous Location approved: 7-TN, -TNK, -T, -T, -TK, -TS, -TG, TGK, -TGS, -TT, -TTS. The following information applies when operating this equipment in hazardous locations: Products marked L I, DIV, GP,,, D are suitable for use in lass I Division Groups,,, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest T number) may be used to help determine the overall temperature code of the system. ombinations of equipment in your system are subject to investigation by the local uthority Having Jurisdiction at the time of installation. WRNING EXPLOSION HZRD Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of components may impair suitability for lass I, Division. If this product contains batteries, they must only be changed in an area known to be nonhazardous. Informations sur l utilisation de cet équipement en environnements dangereux : Les produits marqués "L I, DIV, GP,,, D" ne conviennent qu à une utilisation en environnements de lasse I Division Groupes,,, D dangereux et non dangereux. haque produit est livré avec des marquages sur sa plaque d identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation. RISQUE D EXPLOSION VERTISSEMENT ouper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher l'équipement. ouper le courant ou s'assurer que l environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de lasse I, Division. S assurer que l environnement est classé non dangereux avant de changer les piles. European Hazardous Location pproval The following adapters are European Zone approved: 7-T, -T, -TK, -TS, TG, -TGK, -TGS, -TT, -TTS, -TN, -TNK. European Zone ertification (The following applies when the product bears the Ex or EEx Marking) This equipment is intended for use in potentially explosive atmospheres as defined by European Union Directive //E and has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of ategory equipment intended for use in potentially explosive atmospheres, given in nnex II to this Directive. ompliance with the Essential Health and Safety Requirements has been assured by compliance with EN 007- and EN FLEX I/O age-clamp Terminal ase Units at. No. 7-T, -T, -TK, -T, -TG, -TGK, -TT 0 7 FLEX I/O Spring-clamp Terminal ase Units FLEX I/O Terminal ase Units at. No. 7-TS, -TS, -TGS, -TTS 0 7 at. No. 7-TN, -TNK FLEX I/O Fused Terminal ase Units at. No. 7-TNF, -TNFK T 7-T, -TK -T, -TG, -TGK -TT WRNING Observe the following additional Zone certification requirements. This equipment is not resistant to sunlight or other sources of UV radiation. This equipment must be installed in an enclosure providing at least IP protection when applied in Zone environments. This equipment shall be used within its specified ratings defined by llen-radley. Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 0% when applied in Zone environments. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. FLEX I/O Knifeswitch Terminal ase Unit at. No. 7-TKD 0, 7, 7 Description Female flexbus connector Terminal base unit Male flexbus connector Keyswitch - set to the position required for the installed module Publication 7-IN0D-EN-P - pril 00
3 FLEX I/O Terminal ase Units Mounting holes for panel mounting, 7, Description Input/output terminal strips for connecting inputs/output wiring, commons, power connections, customer power supplies, chassis grounds Locking tab 0 Module locking latch over plug for male flexbus connector old-junction compensation terminals (7-TT, -TTS only) hassis ground terminations (7-TT, -TTS, -TG, -TGS only) Fuses - eight x0 mm (7-TNF, -TNFK only) Terminal strip cover (7-TN, -TNK -TNF, -TNFK only) Knife switches (7-TKD only) Mount the Terminal ase Unit on a DIN Rail Press down on the terminal base to lock it on the DIN rail. If the terminal base does not lock into place, use a screwdriver or similar device to open the locking tab, press down on the base, and release the locking lever to lock the base in During mounting of all devices, be sure that all debris (such as metal chips or wire strands) is kept from falling into the module. Debris that falls into the module could cause damage upon application of power.. Remove the cover plug (if used) in the male connector of the unit to which you are connecting this terminal base unit.. heck to make sure the pins in the male connector on the adjacent device are straight and in line so that the mating female connector on this terminal base unit will mate correctly.. Make certain the female connector () is fully retracted.. Position the terminal base unit on the x 7. DIN rail () (- pt no. -DR). Gently push the flexbus connector into the side of the side of the adapter to complete the backplane connection.. Refer to the installation instructions for specific wiring information for the module you are installing in this terminal base. 7. Repeat the above steps to install the next terminal base. When using FLEX I/O modules in a high-vibration installation, especially when mounting the DIN rail vertically, use DIN-rail locks (- part number -E) to prevent accidental separation of the terminal block units. Do not force the terminal base into the adjacent base/adapter. Forcing the units together can bend or break the hook and allow the units to separate and break communication over the backplane. DIN Rail Position the terminal base at a slight angle and hook it over the top of the DIN rail. Make sure the hook () on the terminal base slides under the edge of the adapter and the flexbus connector is fully retracted. Slide the terminal base over, tight against the adapter.. Rotate the terminal base onto the DIN rail with the top of the rail hooked under the lip on the rear of the terminal base. Use caution to make sure that the female flexbus connector does not strike any of the pins in the mating connector. Publication 7-IN0D-EN-P - pril 00
4 FLEX I/O Terminal ase Units Wire onnections for the Terminal ase Units N N Wiring onnections for the 7-T, 7-TS V OM +V OM +V OM +V OM +V OM +V OM +V OM +V OM N +V = Terminals, 7,, +V = Terminals,, 7, OM = Terminals,, 0, OM = Terminals,,, 0 N = No connections (terminals,,, ) ommon N (7-T shown) Wiring onnections for the 7-T, 7-T, 7-TK, 7-TS Inputs In +V ommons Terminals to 0 not available on 7-T (ommon) = Terminals - and - +V ( In) = Terminals - and - For daisy-chaining: Supply in - - (+) and - (-) Supply out - - (+) and - (-) Wiring onnections for the 7-TG, 7-TGK, 7-TGS hassis V OM V dc Supply In ommon Out +V (7-T shown) hassis N hassis I/O hassis s for Shields N +V OM V dc Supply Out I/O (7-TG shown) hassis +V dc = Terminals -, -0 OM = -, - hassis = Terminals -, -, -, -0 through, -7 N = No connection For daisy-chaining: Supply in - - (+), - (-) Supply out - -0 (+), - (-) Wiring onnections for the 7-TN, 7-TNK, 7-TNF, 7-TNFK OM 0 Even Numbered I/O Terminals 0 to 7 0 OM +V +V Odd Numbered I/O Terminals to +V = Terminals -, - (7-TN shown) OM () = Terminals -, hannel hannel hannel hannel hannel hannel hannel hannel Wiring onnections for the 7-TT, -TTS N0 N N N N N N N V Supply J hassis In +V) = V dc Supply In - Terminals -, - = V dc ommon Terminal - +V = Supply Out - Terminals -0, - = Terminal - = dc common J +V Supply Out (7-TT shown) ommon In +V H0 H H H H H H H7 RET H RET RET RET RET RET RET H0 H H H H H H7 RET Working and Isolation Ratings Terminal ase 7- V 0V 0V Isolation TN, TNK, TNF, TNFK /D /D /D Dependent upon T, T, TK, TS /D /D installed module - refer to individual installation TT, TTS /D /D instructions for your TG, TGK, TGS /D specific module. T, TS /D TKD D Typical Wiring Guidelines Wiring onnections for the 7-TKD ommon +V ( In) = Terminals -, - (ommon) = Terminals -, -, - through -0 For daisy-chaining: Supply in - - (+), - (-) Supply out - - (+), - (-) V dc V dc V dc Wiring when total current draw through base is less than 0. Modules in this configuration must be all analog or all digital. Wiring when total current draw through base is greater than 0. Total current draw through any base must not be greater than 0. Thermocouple or nalog Module Digital Module Digital Module Digital Module Use separate power supplies for analog and digital modules. Wiring when there is a mix of analog and digital modules. ommon Out +V Terminal base units are rated at 0. Spring-clamp Terminal ase Units: 7-TS, -TTS, -TGS, -TS To insert wire, insert a..0 mm ( in.) wide-bladed screwdriver into the slot and lift up. Insert wire, and remove screwdriver. age-clamp Terminal ase Units: 7-T, -T, -TK, -TT, -TG, -TGK, -T Tighten screws to 0. Nm (7 lb-in). Knifeswitch age-clamp Terminal ase Unit: 7-TKD Tighten screws to 0. Nm ( lb-in). NEM Screw-clamp Terminal ase Units: 7-TN, -TNK, -TNF, -TNFK Tighten screws to.0 Nm ( lb-in). Publication 7-IN0D-EN-P - pril 00
5 FLEX I/O Terminal ase Units Install or hange a Fuse in the 7-TNF or 7-TNFK Terminal ase Unit This terminal base unit has fuse holders for x0 mm fuses on each of the eight even-numbered I/O terminals (0 through - row ). To install or change a fuse:. Press the fuse holder down toward the terminal strip. Press down to open. General Wiring category () North merican temp code IE temp code Established by installed module T (7-TG, -TGS, -TGK, -T, -TK, -TT, -TS, -TTS, -TN, -TNK) T (7-T) T (7-TG, -TGS, -TGK, -T, -TK, -TT, -TS, -TTS, -TN, -TNK) T (7-T) () Use this onductor ategory information for planning conductor routing. Refer to Industrial utomation Wiring and ing Guidelines, publication Remove the fuse from the fuse holder.. Insert a known good x0 mm fuse into the fuse holder.. Rotate the fuse holder back to vertical until it snaps into the locked position. The 7-TNF and 7-TNFK terminal base units are shipped with eight x0 mm,., 0V slow-blow fuses, one for each even-numbered terminal (0 through on row ). These fuses are suitable for use with the 7-O ac output module. Refer to the specific installation instructions for fusing recommendations for your particular module. Use the Knifeswitch Terminal ase The knifeswitch terminal base has individual mechanical-knifeswitch circuit breakers (two for each channel). Each switch opens or closes one side (input/output and return) for a channel. Environmental ttribute Operating temperature Non-operating temperature Relative humidity Vibration Operating shock Non-operating shock Value IE 00-- (Test d, Operating old), IE 00-- (Test d, Operating Dry Heat), IE 00-- (Test Nb, Operating Thermal Shock): (- F) (7-TG, -TGS, -TGK, -T, -TK, -TT, -TS, -TTS, T, -TS, -TN, -TNK) 0 ( F) (7-TKD) -0 (- F) (7-TNF, -TNFK, -T) IE 00-- (Test b, Unpackaged Non-operating old), IE 00-- (Test b, Unpackaged Non-operating Dry Heat), IE 00-- (Test Na, Unpackaged Non-operating Thermal Shock): -0 (-0 F) IE (Test Db, Unpackaged Damp Heat): % noncondensing IE 00-- (Test Fc, Operating): 0 00 Hz IE (Test Ea, Unpackaged Shock): 0 g IE (Test Ea, Unpackaged Shock): 0 g ertifications (when product is marked) (). Place a small-bladed screwdriver into the slot of the knifeswitch of the I/O point circuit that you wish to break.. Rotate downward to open the circuit. This opens the path of an individual circuit.. To reestablish the circuit, rotate the knifeswitch back into the terminal base unit until it snaps into place. Specifications ttribute UL c-ul-us Value (7-T) UL Listed Industrial ontrol Equipment. See UL File E. (7-TG, -TGS, -TGK, -T, -TK, -TT, -TS, -TTS, -TN, -TNK) UL Listed Industrial ontrol Equipment, certified for US and anada. See UL File E. UL Listed for lass I, Division Group,,,D Hazardous Locations, certified for U.S. and anada. See UL File E0. (7 -T, -TS, -TKD, -TNF, -TNFK ) UL Listed Industrial ontrol Equipment, certified for US and anada. See UL File E. General ttribute Terminal screw torque Dimensions (HxWxD), approx. (with module installed in terminal base) urrent capacity rating Isolation voltage Enclosure type rating Wire size Value Nm (7... lb-in) (7-T, -T, -T, -TK, -TT, TG, -TGK, T, -TKD, -TN, -TNK, -TNF, -TNFK) x x mm (.7 x.7 x.7 in.) 0 max See chart Established by installed module None (open-style) 0.. mm² (... WG) solid or stranded copper wire rated at 7 (7 F ) or greater,. mm (/ in.) insulation max S E (7-T, -T, -TK, -TT, -TS, -TTS, -TN, -TNK) (7-TG, TGK, TGS Series only) S ertified Process ontrol Equipment. See S File LR. S ertified Process ontrol Equipment for lass I, Division Group,,,D Hazardous Locations. See S File LR0. (7-TNF, -TNFK) S ertified Process ontrol Equipment. See S File LR. European Union 00/0/E EM Directive, compliant with: EN -; Meas./ontrol/Lab., Industrial Requirements EN 000--; Industrial Immunity EN 000--; Industrial Emissions EN -; Programmable ontrollers (lause, Zone & ) European Union 00//E LVD, compliant with: EN -; Programmable ontrollers (lause ) Publication 7-IN0D-EN-P - pril 00
6 ertifications (when product is marked) () -Tick Ex TÜV ustralian Radiocommunications ct, compliant with: S/NZS ISPR ; Industrial Emissions (7-TG, -TGS, -TGK, -T, -TK, -TT, -TS, -TTS, -TN, -TNK) European Union //E TEX Directive, compliant with: EN 007-; Potentially Explosive tmospheres, Protection "n" (II G Ex n II T X) EN 007-0; General Requirements (Zone ) (7-T) European Union //E TEX Directive, compliant with: EN 007-; Potentially Explosive tmospheres, Protection "n" (II G Ex n II T X) EN 007-0; General Requirements (Zone ) (7-TG, -TGS, -TGK, -T, -TK, -TT, -TS, -TTS,-TNF, -TNFK) (7-TG, TGK, TGS Series only) TÜV ertified for Functional Safety: up to and including SIL () See the Product ertification link at for Declaration of onformity, ertificates, and other certification details. Mounting Dimensions mm (in.) (.) (.) (.) (.7) (0.) 7 (.) 0 (.) (0.) 0 (.0) (.) 0 (.) (.7) (.7) (.7) dapter (7-S shown) Terminal ase (7-TS shown) 7 x x x x (. x.7 x.7) (.7 x.7 x.7) Secure DIN rail approximately every 00 mm (7.7 in.). Maintain at least. (.0) air space around your FLEX I/O system installation. = Mounting hole dimensions for optional mounting kit. = DIN rail. = Operating temperature. (.0) below each module when mounted in any position must not exceed ( F). (.7) Terminal ase (7-T shown) x x (.7 x.7 x.7) Measure here for horizontal position. Measure here for vertical mounting position with adapter up. Publication 7-IN0D-EN-P - pril 00 PN- Supersedes Publication 7-IN0-EN-P - May 00 opyright 00 Rockwell utomation, Inc. ll rights reserved.
XM Dynamic Measurement Module Terminal Base
Installation Instructions XM Dynamic Measurement Module Terminal Base Catalog Number 1440-TBS-J Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval
More informationXM-942 Master Relay Terminal Base
XM-942 Master Relay Terminal Base Catalog Number 1440-TB-C Installation Instructions For information about See page Important User Information 2 Safety Approvals 4 Power Requirements 6 Interconnect Limit
More informationXM-940 Dynamic Measurement Terminal Base
XM-940 Dynamic Measurement Terminal Base Catalog Number 1440-TB-A Installation Instructions FOR XM-120...124 ONLY Topic Page Important User Information 2 Power Requirements 8 Interconnect Limit 8 Wiring
More informationProcessLogix Battery Extension Module
Installation Instructions ProcessLogix Battery Extension Module Cat. No. 1757-BEM This document explains how to install the Battery Extension Module (1757-BEM) into the ProcessLogix System. Topic Page
More informationDirect Communication Module
Installation Instructions Direct Communication Module (Catalog Number 1747-DCM) Inside...................................... page For More Information.............................. 3 Hazardous Location
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches
More informationAllen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500
Installation Instructions CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns Catalog Number 2500 Topic Page Important User Information 2 Location Planning 3 Environment 3 Removal
More informationFeeder Circuit Breaker Units Secure Support Pan and Change Door Latch
Installation Instructions Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch Catalog Numbers 2193FZ Topic Page About This Publication 1 Required Tools 1 Important User Information 2
More informationInstallation Instructions. Y-Series Brushless Servo Motor
Installation Instructions Y-Series Brushless Servo Motor Catalog Number Y-1002-1, Y-1002-2, Y-1003-1, Y-1003-2, Y-2006-1, Y-2006-2, Y-2012-1, Y-2012-2, and Y-3023-2 These installation instructions describe
More informationSpare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032
Installation Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Important User Information 2 Precautions 3 Replace the Battery in PanelView Plus Terminals 3 Replace the Battery in
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications
More informationGETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9264 16 AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous This document explains how to connect to the NI 9264. In this document, the NI 9264 with spring terminal and the NI 9264 with
More informationLAL SERIES LED LUMINAIRE
INSTALLATION, OPERATION & MAINTENANCE DATA SHEET LAL SERIES LED LUMINAIRE CAUTION: LAL SERIES LED LUMINAIRE Before installing, make sure you are compliant with area classifications, failure to do so may
More informationGETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate
GETTING STARTED GUIDE NI 9201 8 AI, ±10 V, 12 Bit, 500 ks/s Aggregate This document explains how to connect to the NI 9201. In this document, the NI 9201 with screw terminal, NI 9201 with spring terminal,
More informationGETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous
GETTING STARTED GUIDE NI 9223 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous This document explains how to connect to the NI 9223. Note Before you begin, complete the software and hardware installation procedures
More informationNI 9251 with mini XLR
GETTING STARTED GUIDE NI 9251 with mini XLR 2 AI, 3 Vrms, 24 Bit, 102.4 ks/s/ch Simultaneous, AC/DC Coupling This document explains how to connect to the NI 9251 with mini XLR. Note Before you begin, complete
More informationBattery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions
Installation Instructions Original Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Summary of Changes 1 Important User Information 2 Precautions 3 About This Publication 2 Replace
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationGETTING STARTED GUIDE NI Channel Sinking Digital Input Module
GETTING STARTED GUIDE NI 9421 8-Channel Sinking Digital Input Module This document explains how to connect to the NI 9421. In this document, the NI 9421 with screw terminal, NI 9421 with spring terminal,
More informationPowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions
PowerFlex 7000 AC Drive with Direct-to-Drive Technology Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions Important User Information Solid-state equipment has operational characteristics
More informationInstallation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement
Installation Instructions PowerFlex 700 Drive - Frame 8 Components Replacement Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical
More informationGETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns
GETTING STARTED GUIDE NI 9411 6 DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns This document explains how to connect to the NI 9411. Note Before you begin, complete the software and hardware installation
More informationElectrically Held to Mechanically Latched Contactor
Electrically Held to Mechanically Latched Contactor Bulletin 1502 Series E or later Retrofit Instructions Important User Information Read this document and the documents listed in the Additional Resources
More informationLumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame
Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before
More informationINSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F
SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationRedundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies
Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC
More information- Wiring Brochure Universal Reset Module 422
- Wiring Brochure Universal Reset Module 422 W 422 03/09 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationm WARNING! READ m BEFORE INSTALLATION
m WARNING! READ m BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure, excessive vibration or pressure pulsation, excessive instrument temperature,
More informationTetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide
Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn
More informationM9300 Series Switch Kits
M9300 Series Switch Kits Installation Instructions M9300-1, M9300-2 34-636- 2472, Rev. C (barcode for factory use only) Part No. 34-636-2472, Rev. C Issued June 2017 Application Requirements Refer to the
More informationVA9905 Actuator and VG1600 Series Six-Way Valves
VA9905 Actuator and VG1600 Series Six-Way Valves Installation Instructions *148836003206A* Contents Compliance Information...1 About This Document...1 Accessories...1 Support Information...1 Parts Included...2
More informationKinetix 300 Single-axis Servo Drives
Installation Instructions Kinetix 300 Single-axis Servo Drives Catalog Numbers 2097-V31PR0, 2097-V31PR2, 2097-V32PR0, 2097-V32PR2, 2097-V32PR4, 2097-V33PR1, 2097-V33PR3, 2097-V33PR5, 2097-V33PR6, 2097-V34PR3,
More informationGETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate
GETTING STARTED GUIDE NI 9205 16 AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate This document explains how to connect to the NI 9205. In this document, the NI 9205 with
More information- Wiring Brochure tekmarnet 4 Thermostat 545
- Wiring Brochure tekmarnet 4 545 W 545 12/08 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Layout Brochure ough-in 4 Wiring Brochure
More informationGETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs
GETTING STARTED GUIDE NI 9472 8 DO, 6 V to 30 V, Sourcing, 100 μs This document explains how to connect to the NI 9472. In this document, the NI 9472 with screw terminal, NI 9472 with spring terminal,
More informationBulletin 194R Next Generation Global Fused and Non-Fused Disconnects
Bulletin R IE Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - SA HRII- - SA HRI-MIS - UL lass
More informationGETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs
GETTING STARTED GUIDE NI 9474 8 DO, 5 V to 30 V, Sourcing, 1 μs This document explains how to connect to the NI 9474. In this document, the NI 9474 with screw terminal and the NI 9474 with spring terminal
More informationINSTALLATION INSTRUCTIONS
Page 1 of 2 Ref: IW012346 Rev 4 July 03 Indicators Saxon & Fiesta Series Products Covered 012-**, 013-**, 014-** & 016-** Installation The product should be panel mounted using the mounting kit provided.
More informationSafety Standards. Model Number:
Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,
More informationGETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9244 3 AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous This document explains how to connect to the NI 9244. Note Before you begin, complete the software
More informationSolenoid Operator 0516 / 1216
nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!
More informationMOONRING 1.5 MOONRING 3
INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!
More informationWASP-P PRESSURE SENSOR
WASP-P PRESSURE SENSOR USER MANUAL VERSION 03.22 15/03/2016 WASP is a registered trademark owned by BossPac Engineering & Technology WASP is a PATENT PENDING technology owned by BossPac Engineering & Technology
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMODELS. 2 & 4 Low Profile Linears
INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-2182-99 Rev D December, 2016 MODELS 2 & 4 Low Profile Linears These instructions contain important safety information,
More informationCable Cubby 1202 and 1402 Installation Guide
Cable Cubby 0 and 40 Installation Guide IMPORTANT: Go to www.extron.com for the complete user guide, installation instructions, and specifications. This guide provides instructions for an experienced technician
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationCSD Series Current Devices Split Core
CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch
More informationMINI MCR-SL-UI-UI(-SP)(-NC)
Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify,
More informationSolenoid Operator 0513 / 1213
nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In
More informationAcme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual
Acme Conduit Entry String Combiner/Pass-Through FOR PHOTOVOLTAIC INSTALLATION Installation Manual Table of Contents Important Safety Instructions -----------------------------------------------------------------------------------------------------------
More information505 Size 5 Series A Construction
505 Size 5 Series A Construction With Overload Relays Without Overload Relays Item Part Description Left-Hand Contactor Right-Hand Contactor Both Contactors No. Part Number Part Number Part Number 1 Stationary
More informationThermocouple Thermometer Models
Thermocouple Thermometer Models 91100-00 (Type J) 91100-10 (Type K) 91100-20 (Type T) Cole-Parmer Instrument Company 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847)
More informationMODELS 2 & 4 Top Conduit Linears
INSTALLATION AND MAINTENANCE MANUAL SAFESITE AND DUROSITE LED LINEAR FIXTURE Document No: 9100-127-1885-99 Rev E December, 2016 MODELS 2 & 4 Top Conduit Linears These instructions contain important safety
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationpoollux Power plx-pw60 & plx-pw100
poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation
More informationCable Cubby 650 UT Installation Guide
e NT: RTA.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr Cable Cubby 650 UT Installation Guide This guide provides instructions for an
More informationFan Relay Board (FRBii) Assembly
Fan Relay Board (FRBii) Assembly Installation, Operation, and Maintenance Instructions PK-FCU030-0, PK-FCU050-0 Part No. 24-10143-1221, Rev. A Issued February 2017 Application Refer to the QuickLIT website
More informationMODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions
INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-1622-00 Rev E December, 2016 MODELS SafeSite LED Linear, Class I Div. 1 347-480V, 2 & 4 Versions All the above Models
More informationINDUSTRIAL POWER SUPPLIES SFL-SERIES
INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial
More informationINSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing
SAFETY INSTRUCTIONS IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationINSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1
INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.
More informationINSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit
INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit TRMUNV065ECxyyZ TRAUNV065ECxyyZ Installation Instructions subject to change without notice. Page 1 of 8 1.0 INSTALLATION WARNINGS 1. 2. 3. 4. 5. 6. "THIS
More informationPHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V
PHOTOVOLTAIC SYSTEM CONTROLLERS OPERATOR S MANUAL SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V 6A / 12V 10A / 12V 10A / 24V 20A / 12V 20A
More informationINSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.
INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 Suspended A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5S - Safety & Warnings! 1. Read all instructions. 2.
More informationATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationUHC-202 Hardware Guide
R Description The UHC202 is a fullyintegrated VAV terminal unit controller, complete with differential pressure sensor and integral Belimo LM24M zone damper motor. The UHC202 is designed for singlebox
More informationUZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.
BATTERY MODULE Long Life Battery: 10 to 12 Years According to EUROBAT Small Mounting Footprint Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included 3 Year Warranty,
More informationL-K INDUSTRIES. Criterion Water Bath
L-K INDUSTRIES Demand a higher standard. Criterion Water Bath Class I, Division 2 Heating System Operating Manual To set the standard for MANUFACTURING QUALITY and customer service in the PETROLEUM TESTING
More informationGETTING STARTED GUIDE NI AI, 51.2 ks/s/ch Simultaneous, Universal Measurements
GETTING STARTED GUIDE NI 9218 2 AI, 51.2 ks/s/ch Simultaneous, Universal Measurements This document explains how to connect to the NI 9218. In this document, the NI 9218 with LEMO and the NI 9218 with
More informationUZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS
BATTERY MODULE 24V, 7Ah Battery Capacity (2x 12V Batteries in Series) Small Mounting Footprint 2m Power Leads Included PT1000 Sensor for Battery Module Temperature Included Includes a Center-tap Terminal
More informationINSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.
Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.
More informationINSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight
SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationVA-4233-AGx Series Electric Valve Actuators
Installation Instructions VA-4233 No. 1 Issue Date June 30, 2014 VA-4233-AGx Series Electric Valve Actuators Installation Refer to Figures 2 through 4 for proper actuator orientation before attempting
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationM9300 Series Potentiometer Kits
M9300 Series Potentiometer Kits Installation Instructions M9300-140, M9300-1K, M9300-2K, M9300-10K 34-636- 2480, Rev. C (barcode for factory use only) Part No. 34-636-2480, Rev. C Issued June 2017 Application
More information700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts
Page 1 of 5 Knowledgebase Technote ID # Q19373 3/10/2004 700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction Renewal Parts Figure 1 Page 2 of 5 Knowledgebase Technote ID # Q19373
More informationPowerLogic High Density Metering System 4-Meter Enclosure Installation Guide
PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment
More informationIMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationOutput Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S
Doc. E-92 MKZI1 SERIES D/D ONVERTER 1W, Reinforced Insulation, Railway ertified FEATURES Industrial Standard 2" 1" Package Ultra-wide Input Range 9-36VD, 18-75VD, -1VD I/O Isolation 3VA with Reinforced
More informationM9109 Series Electric Non-spring Return Actuators
34-636- 1190, Rev. D Installation Instructions M9109 Issue Date 03/1/16 M9109 Series Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109 Series actuator only to control equipment
More informationSeries A Construction
Page 1 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 505 Series A Construction 505 505 1495-F1 (1 N.O. auxiliary contact) 1495-G5 (1 N.C. early break auxiliary contact) 1495-H0 ( 1 N.C. late break auxiliary
More informationWet Rated Batten LED Luminaire
Installation Guide Wet Rated Batten LED Luminaire LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before
More informationAPEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS
APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS Product Type: APEX10, APEX20 and APEX40 Servo Drives The above products are in compliance with the requirements of directives 72/23/EEC Low
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings
1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the
More information194R J S TY N1
Bulletin R IE Fused and Non-Fused Disconnects, & A Product Selection omplete UL/SA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More informationi3000s/i2000 Flex AC Current Probe
i3000s/ AC Current Probe Instruction Sheet Introduction The i3000s 24 Flex, i3000s 36 Flex, and AC Current Probes (the Probe) are used with oscilloscopes, digital multimeters, recorders or data loggers.
More informationSIRIUS 3RU2 Thermal Overload Relays
Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to
More informationContents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination
Contents Page... 01.02 3 with HRX Termination... 01.04 3, 3 with HRX Termination... 01.05 4... 01.06 10... 01.07 16... 01.08 32... 01.09 01 Features Metal and plastic version available 3 hoods/housings
More informationBulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts
Page 1 of 8 Knowledgebase Technote ID # Q37160174 5/13/2005 Repair Parts for the Handle/Mechanism and Fusible Disconnect Switch Assembly (See Figure 1 on next page for exploded view of parts.) Catalog
More informationThyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle
Thyristor power controller TE10A Burst-firing Single-cycle Advanced Single-cycle Control of short-wave infrared elements and loads of constant resistance up to 20kW User Manual Copyright Eurotherm Automation
More informationWARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.
Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT
More informationSpun Bay Installation Standard Version (non dimmable), Hook Mount
Spun Bay Installation Standard Version (non dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn
More informationOperating Instructions (Translation)
Product Description Definition The ANTARES RCU consists of the ANTARES Head Module and the ANTARES Connection Module. The ANTARES Head Module contains a CPU, communication interface and power pack. In
More informationM9109-GGx-5 Series Proportional Electric Non-spring Return Actuators
34-636- 1360, Rev. C Installation Instructions M9109-GGx-5 Issue Date March 2016 M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109-GGx-5 Series
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More information