INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Low Pressure Fluid Filters

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

DeZURIK 2 20" BOS BUTTERFLY VALVES

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

ECONOMAIR SERIES CYLINDERS

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC.

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Dual/Triple Manifold Water Filtration Systems Instruction Manual

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

MetroPrime 22MPC Self-Priming Centrifugal Pump

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

Operating and Installation Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Spray Nozzle Adapters

Colt Series C400, C500

Model P-40 & Model P-25 POWER PUSHER

3M Housings CH Series

MODEL G300 BRAKE BLEEDER

Pro Shot Grease Dispense Valve

Scale Feeder Manifold Water Filtration System Instruction Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

Dual Flow Manifold Systems Instruction Manual

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

APCO SRG-6500 SURGE RELIEF GLOBE VALVES

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

OWNER S MANUAL Z SERIES TRACKS. Rev. 355_05

OWNER S MANUAL. LOEGERING th Street SE Casselton, ND USA Fax:

Model FM2642 Wall Mount. Full Motion Television Wall Mount

FOLD N STORE. Table Tennis Table. Assembly Instructions Model , DS, DS CONTACT INFO Hours.

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

DeZURIK KUL KNIFE GATE VALVES

Transmission Guardian

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

L DODGE CUMMINS MK-2 + BLK APPS Mount

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Carbon Steel Nipples

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Service Guide JATCO Environmental Protection Tank Model J-7000

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Installation and Maintenance Manual

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

MODEL G300 Brake Bleeder

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

MODEL 5120 Tire Repair Station

Dual Port Manifold Water Filtration Systems Instruction Manual

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

THIS IS A HIGH PERFORMANCE PRODUCT - USE AT YOUR OWN RISK!!!

PARTS AND INSTALLATION MANUAL

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

Installation Manual DIAPHRAGM WELL TANK

Mudhen Portable Slurry System Owners Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

DODGE CUMMINS Air-Boss CR Intake Plenum

Air Curtain. Installation, Operating and Maintenance Instructions

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

Model E600 Tarping System

INTRODUCTION INSTALLATION

Grinnell Grooved Fire Protection Products Grooved Fittings

6701 KNIFE GATE VALVES

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

25 GALLON PORTABLE OIL LIFT

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

VAN SOLUTIONS FOR THE WAY YOU WORK TM ASSEMBLY AND INSTALLATION INSTRUCTIONS FOR COMPACT SINGLE & DUAL SIDED QUICK CLAMP RACK

Transcription:

PAGE: 1 of 8 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. GIARDIA FILTER SYSTEM NSF/MODEL 8 MULTIPLEX 150 PSIG RATED FILTER UNIT Table of Contents I. Installation............................................................... 2 II. Operation................................................................ 3 Filter System Start-Up Procedure:........................................... 3 III. Spare Parts List........................................................... 5 A. Spare Parts Diagram No. 1, Typical Multi-Plex Configuration....... 6 B. Spare Parts Diagram No. 2, Illustrates Interior Components........ 7 Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 2 of 8 I. Installation Please remove all shipping and crating materials carefully. Be sure to remove the plugs from the inlet and outlet openings. Dispose of all crating materials safely. After positioning the Model 8 Giardia Multiplex Filter System in its proper location, secure the support stand to the floor or platform using the footpads provided. The Model 8 Giardia Multiplex filter is designed as a dual header system. (Your Rosedale Model 8 Giardia Multiplex Filter System consists of multiple Banks of Rosedale Model 8 Giardia Filter units piped with common inlet and outlet headers). The upper header serves as the inlet header and the lower header, nearest the floor, as the outlet header. The inlet service line should be connected to the inlet flange located near the top of the unit (above the basket level). Typically, a blind flange is bolted to the end of the header opposite the service connection. The outlet service line should be connected to the outlet flange located at the bottom of the unit (below the basket level). Typically, a blind flange is bolted to the end of the header opposite the service connection. There are two 1/4" NPT ports on the shell and one 1/4" NPT port on the cover of each Model 8 Giardia Filter unit. There is a 3/4" NPT drain located near the bottom of each Model 8 Filter unit. These ports can remain plugged or be used for pressure gauges or special fittings as your application requires. Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where necessary. After completing installation be sure to double check connections for integrity. Your Model 8 Giardia Multiplex Filter System has been factory pressure tested leak free, therefore, any seepage problems usually occur from improper installation connections. You are now ready to install the filter baskets and Giardia filter bags. Remove the covers by loosening the cover eye nuts. The eye nuts in the slotted corners should be loosened sufficiently to swing free. Loosen the third eye nut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. If your application requires basket seals, insert the basket seals into the basket collar grooves. Refer to Figure 1 in the Spare Parts Diagram for installation position of your seal. Place the baskets into the filter housings, make sure the basket flange is firmly seated into the basket collar. Insert the bags into the bag baskets making sure the filter bag rings are firmly seated inside the basket flanges. For best results, be sure the filter bag is installed fully extended to the bottom of the basket. Before replacing cover assemblys, inspect the cover seal gaskets (replacing if necessary). Close covers and alternately tighten the three clamp assemblies evenly to ensure a leak proof seal between each cover and housing ft-lbs body. The recommended torque value for 5/8"-11 closure assemblies is 60-90. Your Rosedale Model 8 Multiplex Filter System is now ready for operation! Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 3 of 8 II. Operation The Model 8 GiardiaMultiplex system has been designed to operate in series through multiple banks of Model 8 filter units. These banks of filter units can consist of as few as two Model 8 filter units, or as many as ten Model 8 filter units. When it is determined that an individual filter vessel needs cleaning or replacement refer to Filter Media Cleaning/Replacement Procedure. Filter System Start-Up Procedure: Prior to turning on the flow to the inlet service, please make the following checks: 1. Check inside each filter unit to be sure that baskets and filter bags (if applicable) are in the housings and do not require cleaning or replacement. If necessary install clean filter baskets and bags (if applicable). 2. Check that the filter unit covers are securely fastened to the housings. You are now ready to open the flow to the inlet service line. Slowly open the inlet service line approximately 25% of normal operational flow (open slowly as not to displace the filter bags inside the housings). After filter units are pressurized and vented, slowly open outlet service line unit valve until completely open. Complete opening of inlet service line until desired flow rate is reached. Once the desired service flow has been established, the system will operate efficiently until dirty. However, under no circumstances should more than 15 PSI Differential Pressure through the system be obtained. Operating the filter units with a high differential may cause filter bags to rupture and/or cause damage to filter system and downstream equipment. To prevent excessive drop through the filter units, regular inspection of the filter media is required. Monitoring of differential pressure through the housing can be utilized as a means of determining whether or not the filter media needs cleaning or replacement. Filter Media Cleaning/Replacement Procedure (With System not in service) When it becomes necessary to clean or replace filter media, follow the procedure outlined below: 1. First close the flow from the inlet service line tee off header. 2. Close the flow to the outlet service line tee off header. 3. Relieve the pressure from each filter unit. WARNING CONTENTS UNDER PRESSURE Relieve Pressure in accordance with Manufacturer s instructions before opening Filter Vessel. FAILURE TO DO SO MAY RESULT IN SERIOUS BODILY INJURY. 4. Using the 3/4" NPT port, drain housings sufficiently to access filter baskets. 5. Remove covers by loosening the cover eyenuts. The eyenuts in the slotted corners should be Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 4 of 8 loosened sufficiently to swing free. Loosen the third eyenut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. 6. Remove the filter baskets and clean thoroughly, remove the filter bags (if applicable) and throw away. (Cleaning and reusing the filter bag is not recommended.) 7. Remove debris and sludge from inside the inlet portion of each housing to avoid interference with the cover seals or flow of the fluid being filtered. 8. Remove the basket seals and inspect, replace if necessary. Clean basket seal grooves and replace basket seals (see spare parts diagram for location of basket seals). 9. Install clean filter baskets and filter bags (if applicable). Place the baskets into the filter housings, make sure the basket flanges are firmly seated into the basket collars. If applicable, insert bags into the bag baskets making sure filter bag rings are firmly seated inside the basket flanges. For best results, be sure filter bags are installed fully extended to the bottom of the baskets. 10. Inspect cover gasket for cuts or other signs of failure and make sure they are properly seated. 11. Move the covers back into position, and alternately tighten the three clamp assemblies of each cover evenly to ensure a leak proof seal between the covers and housing bodys. The recommended torque value for 5/8"-11 closure assemblies is 60-90 ft-lbs. Your Rosedale Model 8 Giardia Multiplex Filter System is now ready for operation. Refer to filter system start-up procedure. Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 5 of 8 III. Spare Parts List Your Rosedale Model 8 Multiplex Filter System will give you many years of reliable service provided periodic inspections are made of various components and replacement of worn parts are made promptly. The following is meant to be a recommended spare parts list, these parts are illustrated on the following pages. SPARE PARTS LIST Balloon Description Part Number Time-Frame 1 Cover Seal 8150CG-FG as needed 2 Basket Seal 8BG-FG as needed 3 Cover 8CG150-S as needed 4 Eye Nut 8ENNI as needed 5 Rod End 8RENI as needed 6 Clevis Pin Assembly 8CPNI as needed 7 Filter Bag(Pre-Filter) (See Order) as needed 8 Filter Bag(Giardia) GLR-PO-825-2 as needed 9 Filter Basket 0-730-PB as needed 10 3"Class 150 ANSI RFBF Flange w/1"fnpt A16603.16.2 as needed 11 2" Bray Butterfly Valve 5-7216 as needed 12 1/4" Ball Valve 5-8514 as needed 13 1/4" Hose 20" Lg. Teflon/304 5-7288 as needed 14 3" Class 150 Flange Gasket 5-9230 as needed 15 Differential Pressure Gauge w/switch 5-8565 as needed 16 Differential Pressure Gauge 5-8970 as needed 17 DHD Bag Hold Down 8-7474 as needed 18 Standard Bag Hold Down 8-7200 as needed 19 2"Class 150 ANSI RFTF 5-9350 as needed 20 Bolt Set for Butterfly Valves (4), 5/8-11 x 4-1/2" Bolt/Valve Kit as needed 21 Bolt Set for Flange to Flange Connection (4) Bolt/Flange Kit as needed 22 3" Bray Butterfly Valve 5-7217 as needed Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 6 of 8 A. Spare Parts Diagram No. 1, Typical Multi-Plex Configuration Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 7 of 8 B. Spare Parts Diagram No. 2, Illustrates Interior Components Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 8 of 8 Important Notice Warranty: In the event any filtration product is found to be defective in material, workmanship, or not in conformance with any express warranty for a specific purpose, Rosedale s only obligation and your exclusive remedy, shall be to repair, replace or refund the purchase price of such parts or products upon timely notification thereof and substantiation that the product has been stored, maintained and used in accordance with Rosedale s written instructions. EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT. LIMITATION OF LIABILITY: Except as provided above, Rosedale shall not be liable or responsible for any loss or damage, whether direct, indirect, incidental, special or consequential, arising out of sale, use or misuse of Rosedale filtration products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. 3730 West Liberty Road USA 734-665-8201 800-821-5373 Fax. 734-665-2214 email: filters@rosedaleproducts.com http://www.rosedaleproducts.com Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale